isochrone ocx master clock manual

Upload: mcrtech13

Post on 03-Apr-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 Isochrone OCX Master Clock Manual

    1/6

  • 7/28/2019 Isochrone OCX Master Clock Manual

    2/6

    Getting Started:

    I t t a k e s o nl y s e c o nd s t o h a r n es s t h e b e n ef i t s o f t h e I so c h r on e O C X.

    C o n n e ct t h e A C i n p u t t o a p o w e r o ut l e t .

    Connect any devices you'd like clocked to the appropriate outputs on the OCX backpanel.

    Power the OCX on via the power button on the front panel. Proceed to the next stepw h e n th e O v en l i g h t s t o p s f l a s h in g a n d r e m a in s o n .

    Using the Frequency buttons on the front panel, select the sample rate you wish to

    use.

    S o me d e v i ce s w i l l a u to m at i ca l ly s y n c t o i n co m in g c l o ck f r om t h e O C X w h enconnected. Other devices may require additional configuration in order to utilize OCXclock.

    Note: When making initial connections, do so with the studio volume turned down.Some devices may emit unpleasant sound until properly configured to accept incoming

    1

    2

    3

    4

    5

    Isochrone OCX achieves the breakthrough clock stability by placing the quartz crystal inan isolated, temperature controlled oven. Constant temperature control of the crystaloscillator and a proprietary Jitter Management Module provide unprecedented sonicbenefits. Isocrone OCX t a k e s t h e d i g it a l s o u n d ou t o f d i g it a l a u d i o, g i v i n g yo u t h e a ud i oin its purest form whether connected to digital mixer, Pro-Tools system, DAW or digitaleffects unit.

    The amazingly stable Isochrone OCX can be taken to theultimate level by locking it to the most stable clock on Earth: the Atomic clock.

    With added flexibility of being able to output multiple sample rates and the built in supportfor Pro Tools, Isocrone OCX e a si l y s u rp a ss e s t h e i n du s tr y s t an d ar d A ar d Sy n c I I , a nd i sd e s t i ne d t o b e c o me t h e n e w G o l d S t a nd a r d .

  • 7/28/2019 Isochrone OCX Master Clock Manual

    3/6

    Front Panel

    Power Switch

    Oven Indicator W h en t h e O C X i s p o we r ed o n , t hi s L E D w i ll f l as h w h il e t h e o ve n c a li b ra t es i t s

    t e m p er a t u re . T h e L E D w i l l r e m a in l i t w h e n t h i s t e m p er a t u re is a c h i e ve d . T h i s p r o c es sonly takes a moment, and verifies optimum hardware performance.

    Atomic Clock IndicatorW h e n l i t, t h i s L E D v e r i fi e s t h at t h e O C X i s s l a v i ng t o A t o m i c Cl o c k v i a th e c o r re s p o n di n gB N C i n p u t o n t he u n i t ' s b a ck p a n e l .

    Sample Rate SelectorsU s e d t o s el e c t t h e op e r a ti n g f r eq u e n c y of t h e O C X c l o c k . A l l o u t p ut s ( W or d C l o c k,AES/EBU, and S/PDIF) will output this frequency with the exception of outputs 7 and 8.Outputs 7 & 8 can operate at this rate or provide user defined frequencies. See for more details

    Frequency DisplayDisplays the operating frequency of the OCX clock.

    Contrast KnobAdjusts the frequency display contrast.

    1

    2

    3

    4

    7

    5

    6

    1 2 3 4 5 6 7 7

    Front Panel

    7

  • 7/28/2019 Isochrone OCX Master Clock Manual

    4/6

    Alternate Sample Rate Switches for Word Clock outputs 7 and 8.Word clock outputs 7 and 8 are capable of outputting frequencies different from the OCXinternal clock. The first five settings choose frequencies that are multiples of the internalc l o c k . T h e f i n a l s e t t i ng , 256 WC, c o n f ig u r e s t h e o u tp u t t o ge n e r at e 2 5 6 F S C l o c k ( o r Superclock), a protocol used by some Digidesign components.A red LED is present above each knob. When lit, it indicates that a valid sample rate isselected. When flashing, the output has been configured to provide a frequency outsidethe supported range (32kHz- 192 kHz).

    For easy reference, the following chart indicates what frequencies outputs 7 and/or 8 willprovide depending on knob position and the selected sample rate.

    7

    32 kHz

    44.1 kHz

    48 kHz

    88.2 kHz

    96 kHz

    176.4 kHz

    192 kHz

    X

    X

    X

    X

    X

    44.1 kHz

    48 kHz

    WC / 4

    X

    X

    X

    88.2 kHz

    96 kHz

    44.1 kHz

    48 kHz

    WC /2

    32 kHz

    44.1 kHz

    48 kHz

    88.2 kHz

    96 kHz

    176.4 kHz

    192 kHz

    WC

    X

    X

    88.2 kHz

    64 kHz

    96 kHz

    176.4 kHz

    192 kHz

    2 WC

    X X

    X

    X

    X

    X

    X

    X

    176.4 kHz

    128 kHz

    192 kHz

    4 WC

    256 fs

    256 fs

    256 fs

    256 WC

    ALTE R N ATE SA MP LE R AT E

    SAMPLE

    RATE

    X O u t p u t i s no t v al i d

  • 7/28/2019 Isochrone OCX Master Clock Manual

    5/6

    R ea r P an el

    Power ConnectionT h i s I E S A C c o n n e ct i o n a c c e p ts a n i np u t o f 9 5- 2 4 5 VA C 5 0 / 6 0 H z . A s a r e s u l t, t he O C Xautomatically accommodates a full range of voltages, allowing safe use in any country.

    Atomic Clock In and Thru connectorsT h e A t o m i c C l o c k I n p u t a l l o w s t h e O C X t o o p e r at e wi t h u n p r ec e d e nt e d a c c u r ac y. T h i s B N Ci n p u t a c c e p ts t h e 1 0 M H z c l o c k s i g n a l f o u n d o n m an y a to m i c c l o c k d e v i c es . T h e OC X c a n

    utilize this ultra precise timing reference at any of its supported sample rates.

    T h e A t o m i c C lo c k T h ru a l l o w s a d di t i o n al d e v i c es t o s l a v e t o A t o m i c C lo c k r e c e i ve d b y t h eO C X . T h i s a ll o w s ad d i t i on a l O C X u n i t s t o b e pr e s e n t i n t h e st u d i o, a l l u t i l i zi n g t he b e n ef i t sof atomic clock in perfect sync.

    Word Clock outputs 1-6 The sample rate provided by these BNC outputs alwaysmatches the sample rate indicated by the Frequency Display on the front panel.For best results, WC cables should not exceed 20ft. (6m.) in length. Longer cable runsresult in increased jitter and other clock errors.

    Word Clock outputs 7-8The sample rate provided by these two outputs can match the sample rate of outputs 1-6 or be changed to alternate sample rates by using the corresponding knobs on the front panel.

    AES/EBU outputsP r o v i de c l o c k i n t h e A E S / E B U f o r m at . A ES / E B U i s t h e b e s t o pt i o n i n s i tu a t i on s r e q u ir i n gl o n g ca b l e ru n s . A E S / E B U a c c o mm o d a te s c a b l e r u n s up t o 3 00 f t . (9 0 m . ).

    S/PDIF outputsR C A c o n n ec t i o n s p ro v i d e c l oc k v i a C o a x i a l S / P D I F.For best results, S/PDIF connections should not exceed 10ft. (3m.).

    8

    9

    10

    11

    12

    13

    8 9 10 11 12 13

    Rear Panel

  • 7/28/2019 Isochrone OCX Master Clock Manual