isofootcandle lines of horizontal illumination values … · 2018. 9. 26. · 1 0 1 2 01234567...

12
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA PHONE: (303) 442-1255 FAX: (970) 535-3114 E-MAIL: [email protected] WEBSITE: www.itlboulder.com NVLAP LAB CODE: 200925-0 ® THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 4 3 2 1 0 1 2 0 1 2 3 4 5 6 7 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting Heights House Side Street Side Approved Checked M KLOPF R BEATTIE Lighting Engineer 1 .5 .2 .1 .05 .02 .01 .005 .002 IES Cutoff Classification: Cutoff REPORT NUMBER: ITL88130-GONIOPHOTOMETRY ISSUE DATE: 08/15/16 PAGE: 1 OF 8 PREPARED FOR: EVLUMA CATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0 LUMINAIRE: CAST FINNED METAL HOUSING WITH FORMED METAL ACCESS DOOR, 32 LEDS, WHITE FIBROUS REFLECTOR, FABRICATED MULTI-FACETED SEGMENTED METAL CENTER REFLECTOR WITH PREMIUM SPECULAR FINISH, CLEAR MICRO-PRISMATIC GLASS DROP LENS, LENS PRISMS OUT. LAMPS: THIRTY-TWO WHITE LIGHT EMITTING DIODES (LEDS) EACH WITH CLEAR HEMISPHERICAL INTEGRAL LENS, VERTICAL BASE-UP POSITION. INPUT ELECTRICAL: 120.0 VOLTS, 69.2 WATTS, 0.579 AMPS LED DRIVER: EVLUMA PROPRIETARY NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT. TEST PROCEDURE: IESNA LM-79-08 TEST DISTANCE = 20.0 FEET 11 11 1/2 11 17 7/8

Upload: others

Post on 15-Aug-2021

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATIONValues based on 25 foot mounting height.

4

3

2

1

0

1

2

0 1 2 3 4 5 6 7Longitudinal Distance in Units of Mounting Heights

Tra

nsve

rse

Dis

tanc

e in

Uni

ts o

f Mou

ntin

g H

eigh

tsH

ouse

Sid

eS

tree

t Sid

e

Approved

Checked M KLOPF

R BEATTIELighting Engineer

1

.5

.2

.1

.05

.02 .01 .005.002

IES Cutoff Classification: Cutoff

REPORT NUMBER: ITL88130-GONIOPHOTOMETRYISSUE DATE: 08/15/16 PAGE: 1 OF 8PREPARED FOR: EVLUMACATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0LUMINAIRE: CAST FINNED METAL HOUSING WITH FORMED METAL ACCESS DOOR, 32 LEDS, WHITE FIBROUS REFLECTOR, FABRICATED MULTI-FACETED SEGMENTED METAL CENTER REFLECTOR WITH PREMIUM SPECULAR FINISH, CLEAR MICRO-PRISMATIC GLASS DROP LENS, LENS PRISMS OUT.LAMPS: THIRTY-TWO WHITE LIGHT EMITTING DIODES (LEDS) EACH WITH CLEAR HEMISPHERICAL INTEGRAL LENS, VERTICAL BASE-UP POSITION.INPUT ELECTRICAL: 120.0 VOLTS, 69.2 WATTS, 0.579 AMPSLED DRIVER: EVLUMA PROPRIETARYNOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT.TEST PROCEDURE: IESNA LM-79-08TEST DISTANCE = 20.0 FEET

1111 1/2

11

17 7/8

Page 2: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

30° 0° 30°

60°

90°

120°

150°180°

90°

60°

HOUSESIDE

STREETSIDE

CA

ND

EL

A

MAXIMUM PLANE AND MAXIMUM CONE PLOTS OF CANDELA

VERTICAL PLANE THROUGH MAXIMUM CANDELA CONE THROUGH MAXIMUM CANDELA

560

1120

1680

61.0 (Degrees Vertical) 155.0 (Degrees Horizontal) = 1693

REPORT NUMBER: ITL88130-GONIOPHOTOMETRYISSUE DATE: 08/15/16 PAGE: 2 OF 8PREPARED FOR: EVLUMACATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0LUMINAIRE: CAST FINNED METAL HOUSING WITH FORMED METAL ACCESS DOOR, 32 LEDS, WHITE FIBROUS REFLECTOR, FABRICATED MULTI-FACETED SEGMENTED METAL CENTER REFLECTOR WITH PREMIUM SPECULAR FINISH, CLEAR MICRO-PRISMATIC GLASS DROP LENS, LENS PRISMS OUT.LAMPS: THIRTY-TWO WHITE LIGHT EMITTING DIODES (LEDS) EACH WITH CLEAR HEMISPHERICAL INTEGRAL LENS, VERTICAL BASE-UP POSITION.INPUT ELECTRICAL: 120.0 VOLTS, 69.2 WATTS, 0.579 AMPSLED DRIVER: EVLUMA PROPRIETARYNOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT.TEST PROCEDURE: IESNA LM-79-08TEST DISTANCE = 20.0 FEET

Page 3: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-GONIOPHOTOMETRY PAGE: 3 OF 8ISSUE DATE: 08/15/16PREPARED FOR: EVLUMA

COEFFICIENTS OF UTILIZATION AND FLUX DISTRIBUTION

PERCENT LUMENS OF FIXTURE

DOWNWARDSTREET SIDE 3771 49.7

DOWNWARDHOUSE SIDE 3769 49.7

DOWNWARDTOTAL 7540 99.4

UPWARDSTREET SIDE 25 0.3

UPWARDHOUSE SIDE 18 0.2

UPWARDTOTAL 43 0.6

TOTALFLUX 7583 100.0

EFFICACY = 109.6 lm/W

ALL CANDELA AND LUMENS IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY.THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTELUMEN OUTPUT OF THIS LUMINAIRE SAMPLE.

0 1 2 3 4 50.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

Street Width / Mounting Height

Coefficients of Utilization

HOUSE SIDE

STREET SIDE

Page 4: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-GONIOPHOTOMETRY PAGE: 4 OF 8ISSUE DATE: 08/15/16PREPARED FOR: EVLUMA

FLUX DISTRIBUTION BY SOLID ANGLE

(PER IESNA TM-15-11, LUMINAIRE CLASSIFICATION SYSTEM FOR OUTDOOR LUMINAIRES)

PERCENT BUG OF ZONE LUMENS FIXTURE RATINGS

FORWARD LIGHT 3771. 49.7 FL ( 0- 30) 566.8 7.5 FM ( 30- 60) 1755.0 23.1 FH ( 60- 80) 1296.9 17.1 G1 FVH( 80- 90) 152.1 2.0 G2

BACK LIGHT 3769. 49.7 BL ( 0- 30) 560.8 7.4 B2 BM ( 30- 60) 1768.4 23.3 B2 BH ( 60- 80) 1295.6 17.1 B3 G1 BVH( 80- 90) 144.1 1.9 G2

UPLIGHT 43. 0.6 UL ( 90-100) 40.9 0.5 U2 UH (100-180) 2.1 0.0 U1

TRAPPED LIGHT 0. 0.0

TOTAL FLUX 7583. 100.0

BACKLIGHT, UPLIGHT, AND GLARE (BUG) RATINGS (PER ADDENDUM A FOR IESNA TM-15-11)

BUG RATING: B3 U2 G2

Page 5: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-GONIOPHOTOMETRY PAGE: 5 OF 8ISSUE DATE: 08/15/16PREPARED FOR: EVLUMA

CANDELA TABULATION

STREET SIDE LATERAL ANGLE 0.0 5.0 15.0 25.0 35.0 45.0 55.0 65.0 75.0 85.0 90.0 180.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 175.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 165.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 155.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 145.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 135.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 125.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 115.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 105.0 2. 2. 2. 2. 2. 2. 2. 2. 2. 2. 2. 95.0 33. 32. 35. 37. 35. 35. 33. 32. 31. 30. 30. 92.5 61. 61. 67. 70. 68. 67. 66. 65. 63. 62. 62. 90.0 100. 105. 111. 116. 112. 112. 109. 105. 107. 105. 106. 87.5 168. 167. 172. 177. 175. 175. 170. 166. 168. 168. 168. 85.0 253. 251. 259. 261. 259. 259. 255. 250. 254. 253. 253. V 82.5 368. 364. 373. 376. 373. 375. 372. 372. 370. 373. 368. E 80.0 522. 518. 528. 527. 529. 530. 531. 530. 528. 537. 523. R 77.5 715. 708. 721. 721. 736. 740. 732. 741. 728. 738. 720. T 75.0 941. 933. 948. 947. 964. 967. 969. 974. 969. 968. 951. I 72.5 1181. 1167. 1184. 1197. 1198. 1206. 1209. 1217. 1215. 1212. 1198. C 70.0 1407. 1392. 1406. 1419. 1420. 1428. 1428. 1432. 1428. 1426. 1426. A 67.5 1551. 1547. 1544. 1558. 1548. 1566. 1555. 1566. 1552. 1554. 1558. L 65.0 1613. 1610. 1604. 1626. 1600. 1631. 1615. 1630. 1619. 1629. 1633. 62.5 1654. 1639. 1624. 1651. 1631. 1670. 1640. 1666. 1648. 1653. 1671. A 61.0<< 1653. 1636. 1623. 1652. 1627. 1665. 1640. 1662. 1651. 1660. 1675. N 60.0 | 1644. 1634. 1621. 1642. 1625. 1664. 1640. 1659. 1646. 1660. 1673. G 57.5 | 1611. 1615. 1601. 1619. 1596. 1631. 1617. 1633. 1633. 1644. 1652. L 55.0 | 1569. 1567. 1561. 1565. 1566. 1581. 1579. 1591. 1593. 1602. 1607. E 52.5 | 1520. 1526. 1525. 1525. 1521. 1529. 1536. 1542. 1548. 1551. 1554. 50.0 | 1486. 1488. 1487. 1494. 1494. 1491. 1491. 1500. 1499. 1509. 1507. 47.5 | 1472. 1467. 1470. 1467. 1466. 1467. 1472. 1471. 1474. 1477. 1477. 45.0 | 1477. 1471. 1466. 1470. 1465. 1466. 1462. 1470. 1470. 1467. 1469. 42.5 | 1483. 1484. 1481. 1479. 1483. 1474. 1479. 1473. 1478. 1480. 1477. 40.0 | 1498. 1499. 1507. 1493. 1508. 1495. 1503. 1494. 1500. 1494. 1491. 37.5 | 1511. 1514. 1520. 1512. 1519. 1514. 1520. 1514. 1510. 1512. 1512. 35.0 | 1534. 1524. 1526. 1520. 1523. 1514. 1517. 1514. 1514. 1511. 1516. 30.0 | 1500. 1506. 1506. 1507. 1509. 1504. 1510. 1505. 1497. 1495. 1499. 25.0 | 1446. 1445. 1453. 1452. 1452. 1453. 1453. 1450. 1442. 1442. 1435. 20.0 | 1327. 1322. 1331. 1324. 1331. 1329. 1326. 1324. 1317. 1314. 1314. 15.0 | 1205. 1199. 1202. 1203. 1208. 1210. 1204. 1210. 1207. 1209. 1203. 10.0 | 1195. 1196. 1193. 1200. 1199. 1195. 1205. 1203. 1206. 1206. 1207. 5.0 | 1232. 1231. 1229. 1236. 1239. 1234. 1242. 1242. 1239. 1239. 1237. 0.0 | 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. | | | CONE OF MAXIMUM CANDELA

Page 6: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-GONIOPHOTOMETRY PAGE: 6 OF 8ISSUE DATE: 08/15/16PREPARED FOR: EVLUMA

CANDELA TABULATION

HOUSE SIDE LATERAL ANGLE 95.0 105.0 115.0 125.0 135.0 145.0 155.0 165.0 175.0 180.0 || 180.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 175.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 165.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 155.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 145.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 135.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 125.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 115.0 0. 0. 0. 0. 0. 0. 0. 0. 0. 0. 105.0 2. 1. 1. 1. 1. 1. 0. 0. 0. 0. 95.0 30. 27. 25. 24. 24. 19. 14. 10. 8. 8. 92.5 60. 55. 50. 51. 51. 45. 40. 34. 25. 27. 90.0 104. 100. 91. 93. 97. 90. 90. 95. 93. 95. 87.5 166. 163. 152. 155. 162. 158. 157. 157. 154. 154. 85.0 250. 248. 240. 244. 247. 239. 236. 237. 233. 234. V 82.5 371. 364. 363. 360. 360. 349. 346. 348. 342. 344. E 80.0 536. 521. 521. 516. 512. 500. 495. 499. 493. 498. R 77.5 737. 722. 731. 725. 708. 694. 688. 696. 686. 694. T 75.0 966. 953. 965. 955. 937. 923. 918. 928. 916. 923. I 72.5 1211. 1210. 1209. 1205. 1185. 1175. 1166. 1180. 1167. 1174. C 70.0 1428. 1426. 1428. 1425. 1430. 1413. 1421. 1415. 1405. 1410. A 67.5 1556. 1546. 1563. 1555. 1569. 1554. 1563. 1555. 1561. 1558. L 65.0 1624. 1623. 1637. 1624. 1652. 1629. 1642. 1629. 1638. 1639. 62.5 1656. 1656. 1677. 1657. 1687. 1664. 1681. 1660. 1667. 1681. A 61.0<< 1662. 1663. 1685. 1661. 1689. 1663. 1693. 1668. 1666. 1693. N 60.0 | 1660. 1660. 1682. 1663. 1687. 1664. 1686. 1670. 1671. 1682. G 57.5 | 1645. 1641. 1655. 1642. 1663. 1650. 1662. 1648. 1646. 1655. L 55.0 | 1601. 1602. 1613. 1604. 1618. 1605. 1622. 1615. 1609. 1612. E 52.5 | 1553. 1559. 1550. 1556. 1564. 1563. 1562. 1564. 1567. 1555. 50.0 | 1509. 1510. 1513. 1506. 1507. 1518. 1501. 1513. 1515. 1519. 47.5 | 1481. 1482. 1481. 1483. 1477. 1483. 1479. 1484. 1483. 1482. 45.0 | 1466. 1476. 1470. 1476. 1474. 1468. 1473. 1473. 1478. 1474. 42.5 | 1486. 1489. 1477. 1488. 1478. 1477. 1482. 1487. 1483. 1491. 40.0 | 1500. 1499. 1499. 1501. 1500. 1499. 1489. 1498. 1504. 1505. 37.5 | 1509. 1516. 1505. 1517. 1505. 1507. 1509. 1506. 1519. 1512. 35.0 | 1508. 1512. 1517. 1512. 1520. 1521. 1507. 1512. 1519. 1507. 30.0 | 1495. 1496. 1498. 1497. 1500. 1493. 1492. 1490. 1499. 1495. 25.0 | 1433. 1438. 1433. 1431. 1433. 1435. 1427. 1424. 1419. 1420. 20.0 | 1315. 1309. 1307. 1302. 1295. 1300. 1293. 1285. 1276. 1283. 15.0 | 1207. 1200. 1201. 1198. 1193. 1192. 1186. 1183. 1183. 1176. 10.0 | 1203. 1211. 1205. 1206. 1205. 1205. 1200. 1205. 1205. 1206. 5.0 | 1233. 1233. 1232. 1231. 1229. 1227. 1231. 1224. 1225. 1222. 0.0 | 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. 1229. | || | PLANE OF MAXIMUM CANDELA | CONE OF MAXIMUM CANDELA

Page 7: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-GONIOPHOTOMETRY PAGE: 7 OF 8ISSUE DATE: 08/15/16PREPARED FOR: EVLUMA

5-DEGREE 10-DEGREEZONAL LUMEN SUMMARY ZONAL LUMEN SUMMARY 0- 5 29 0- 10 117 5- 10 87 0- 20 465 10- 15 142 0- 30 1128 15- 20 206 0- 40 2076 20- 25 290 0- 50 3224 25- 30 373 0- 60 4651 30- 35 445 0- 70 6233 35- 40 504 0- 80 7244 40- 45 549 0- 90 7540 45- 50 599 0-100 7581 50- 55 673 0-110 7583 55- 60 754 0-120 7583 60- 65 802 0-130 7583 65- 70 780 0-140 7583 70- 75 622 0-150 7583 75- 80 389 0-160 7583 80- 85 203 0-170 7583 85- 90 93 0-180 7583 90- 95 33 95-100 8100-105 2105-110 0110-115 0115-120 0120-125 0125-130 0130-135 0135-140 0140-145 0145-150 0150-155 0155-160 0160-165 0165-170 0170-175 0175-180 0

Page 8: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC.4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303) 442-1255 • FAX: (970) 535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-GONIOPHOTOMETRY PAGE: 8 OF 8ISSUE DATE: 08/15/16PREPARED FOR: EVLUMA

ADDRESS: 3600 LIND AVE. SW SUITE 140 RENTON, WA 98057

THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BYTHE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENTBY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

Page 9: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-SPHERE Page 1 of 4DATE: 08/18/16PREPARED FOR: EVLUMACATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0

ADDRESS: 3600 LIND AVE. SW SUITE 140 RENTON, WA 98057

LUMINAIRE: CAST FINNED METAL HOUSING WITH FORMED METAL ACCESS DOOR, 32 LEDS, WHITE FIBROUS REFLECTOR, FABRICATED MULTI-FACETED SEGMENTED METAL CENTER REFLECTOR WITH PREMIUM SPECULAR FINISH, CLEAR MICRO-PRISMATIC GLASS DROP LENS, LENS PRISMS OUT.

LAMP: THIRTY-TWO WHITE LIGHT EMITTING DIODES (LEDS) EACH WITH CLEAR HEMISPHERICAL INTEGRAL LENS, VERTICAL BASE-UP POSITION.

DRIVER: EVLUMA PROPRIETARY

NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED AT RATED INPUT VOLTAGE (120VAC, 60Hz) TO THE DRIVER. DRIVER INFORMATION PROVIDED BY CLIENT. Calibration Due: INSTRUMENTS: Associated Power Technologies APT5040 AC Power Source N/A Yokogawa WT210 Digital Power Meter #6 12/07/16 Ocean Optics QE65000 Spectroradiometer 04/19/17 ITL 2.0m Diameter Integrating Sphere S20-2, 4PI Geometry 04/19/17

OBJECT OF TEST: Measure the Absolute Flux in lumens*, Spectral Power Distribution (SPD), Correlated Color Temperature (CCT), Color Rendering Index (CRIa,1-14), Chromaticity Coordinates (x,y; u’,v’), ANSI C78.377 Duv, Total Radiant Flux*, Scotopic / Photopic Lumen Ratio, and electrical data including ANSI C82.77-2002 Power Factor (PF) and Total Harmonic Distortion (THD) to the test sample.

PROCEDURE: The test sample was provided by the customer and had an unknown number of operating hours. The test sample was mounted inside the integrating sphere and allowed to stabilize. After stabilization occurred, measurements were taken. In order to measure mean performance, multiple data sets were recorded and averaged. Readings were taken with the test sample operating at 120VAC input in a 25 +/-1 degree Celsius free air ambient and in accordance with IESNA LM-79-08. All data are traceable to the National Institute of Standards and Technology.

RESULTS: (continued subsequent pages) THIS ITL REPORT WITH THE USE OF THE NVLAP LOGO SHALL NOT BE USED BY THE CLIENT TO CLAIM PRODUCT CERTIFICATION, APPROVAL, OR ENDORSEMENT BY NVLAP, NIST, OR ANY AGENCY OF THE FEDERAL GOVERNMENT.

Sphere Lab SupervisorApproved

Checked N WHITE

P O’CONNOR

Page 10: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-SPHERE Page 2 of 4DATE: 08/18/16PREPARED FOR: EVLUMACATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0

RESULTS:

PHOTOMETRIC Total Integrated Flux (lumens) SPECTRORADIOMETRIC Observer Chromaticity Ordinate x Chromaticity Ordinate y Observer Chromaticity Ordinate u’ Chromaticity Ordinate v’ Correlated Color Temp CCT (K) ANSI C78.377-2008 Duv Total Radiant Flux (milliWatts) Scotopic / Photopic Lumen Ratio ELECTRICAL Input Voltage (Volts AC ) Input Current (Amps AC ) Input Power (Watts) Input Power Factor (%) Input Current THD (%) Input Voltage THD (%) EFFICACY (lumens/Watt)

7583 * CIE 1931 2 degree 0.3864 0.3844 CIE 1976 2 degree 0.2259 0.5058 3900 0.002 22295 * 1.499 120.0 0.579 69.3 99.7 6.6 0.2 109.4

COLOR RENDERING INDICES Ra (Average 1-8) R1 Light greyish red R2 Dark greyish yellow R3 Strong yellowish green R4 Moderate yellowish green R5 Light bluish green R6 Light blue R7 Light violet R8 Light reddish purple R9 Strong red R10 Strong yellow R11 Strong green R12 Strong blue R13 Light yellowish pink (skin) R14 Moderate olive green (leaf)

CRI 72 70 76 83 74 70 69 79 55 -24 46 72 48 70 90

*NOTE: The total lumen output shown on this report was obtained from photometric test ITL88130-GONIOPHOTOMETRY

Page 11: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-SPHERE Page 3 of 4DATE: 08/18/16PREPARED FOR: EVLUMACATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0

RESULTS:

Wavelength mW per nm Wavelength mW per nm Wavelength mW per nm 380 0.708 515 77.355 650 59.328 385 0.890 520 85.923 655 52.719 390 1.104 525 92.737 660 46.517 395 1.596 530 98.170 665 40.904 400 2.476 535 102.441 670 35.841 405 4.458 540 106.051 675 31.233 410 8.895 545 109.781 680 27.223 415 18.495 550 113.231 685 23.639 420 36.525 555 116.724 690 20.526 425 62.928 560 120.266 695 17.781 430 92.218 565 124.054 700 15.316 435 122.410 570 127.467 705 13.242 440 144.409 575 130.208 710 11.426 445 122.045 580 132.200 715 9.862 450 72.830 585 133.512 720 8.498 455 43.509 590 133.137 725 7.332 460 29.418 595 131.641 730 6.321 465 19.799 600 128.628 735 5.460 470 14.866 605 124.491 740 4.712 475 13.334 610 119.088 745 4.073 480 13.589 615 112.852 750 3.543 485 16.446 620 105.738 755 3.070 490 22.557 625 97.833 760 2.652 495 31.682 630 89.993 765 2.296 500 42.968 635 82.096 770 1.983 505 55.177 640 74.158 775 1.723 510 66.915 645 66.537 780 1.508

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

0.0

30.0

60.0

90.0

120.0

150.0

Out

put (

mW

/nm

)

380.0 420.0 460.0 500.0 540.0 580.0 620.0 660.0 700.0 740.0 780.0Wavelength (nm)

Output vs. Wavelength

Page 12: ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values … · 2018. 9. 26. · 1 0 1 2 01234567 Longitudinal Distance in Units of Mounting Heights Transverse Distance in Units of Mounting

THE LIGHT CENTER OF THE INDUSTRY SINCE 1955

INDEPENDENT TESTING LABORATORIES, INC. 4066 CAMELOT CIRCLE, LONGMONT, CO 80504 USA

PHONE: (303)442-1255 • FAX: (970)535-3114 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com

NVLAP LAB CODE: 200925-0

®

THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.

REPORT NUMBER: ITL88130-SPHERE Page 4 of 4DATE: 08/18/16PREPARED FOR: EVLUMACATALOG NUMBER: AMAX-70-4K-6-V-D-S3-0

CIE Chromaticity Diagram