isotecsec synergy user manual 1-22-15 · 1 ion, and sy and the ‘c’ noccupied a upied and t...

26
Isotec Se ecurity Inc, 64 SYNE 424 W. 91 st Av ERGY ® Op PLC S Displa e, Westminste ® Colo peratio Weapons Software: ay Software r, CO 80031 or Ope ons M Control S Vi45: 1/2 e: Vi43: 1/2 303-452-002 erator Manua System 22/15, or la 22/15, or la 22 www.isote r Cons al ater ater ecinc.com sole

Upload: others

Post on 11-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

Isotec Se

ecurity Inc, 64

SYNE

424 W. 91st Av

ERGY®

Op

PLC SDispla

e, Westminste

® Colo

peratioWeapons

Software: ay Software

r, CO 80031

or Ope

ons M

Control S

Vi45: 1/2e: Vi43: 1/2

303-452-002

erator

ManuaSystem

22/15, or la22/15, or la

22 www.isote

r Cons

al

ater ater

ecinc.com

sole

Page 2: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

This docSYNERGdocumenfeatures ThroughoconfiguradescriptioSingle Lamode baswitch to Note alsophysical shown in The use screen, asections. MAIN SC In norma

e 2

O

ument descrGY Touchscrnt reflects feanoted may n

out this manation. For Sons of the opane system sed on som

o an Exit arro

o that the mainstallation.

n this docum

of the touchand the vario.

CREEN

al operation,

Operato

ribes the scrreen Consolatures suppnot exist in p

nual, the exaingle Lane sperations aris normally ieone walkin

ow when the

ain screen w Hence, theent. The op

screen is quous controls

the Main sc

or Conso

reen imagesles, as supported in the

previous rele

amples are asystems (onee essentiallyn the Entry (

ng up to the ie system is in

will be config portal orien

peration is id

uite intuitive that show o

creen will be

ole Oper

s and controllied with varlatest revisio

eases.

all shown for e lane operay identical. T(Lane) modeinterior (B) dn Exit mode.

gured by the ntation and sentical.

and flows inon that scree

displayed a

1

ration M

ls available rious Safety on of the con

r a dual lane ates as both The only mae, and it switdoor. The E.

factory to mshape may lo

n a very preden, are descr

s follows:

1/22/15

Manual

in Isotec SeEntrance prnsole softwa

system of aentry and e

ajor differenctches to the ntry arrow o

most closely ook different

dictable fashribed in the f

curity’s roducts. Thiare. Some

an ANSI xit lane), thece is that theExit (Lane)

on the screen

represent yot than what i

hion. Each following

is

e e

n will

our s

Page 3: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The outli(unprotecIndicatorcolors), atime. Th In additioscreen a The Videviewing s The Inteintercom person ayellow fosymbol. Volume panel to Normal E The statilocked (tosymbol wopen andappears person mlane. If nuser maycontinuodoor is c

EXTERIOR

e 3

ne on the sccted) part ofrs are providand whethere screen in

on to the conlso has cont

eo button atscreen, whic

rcom buttonstation in t

at the intercoor 10 seconAn “incomin

for both intethe right of t

Entry Seque

c (unoccupieop view in th

will change frd yellow), theshowing the

moves towardno metal is dy open the ‘Bus transitionlosed and lo

E X T E R

O R

E X T E R I O R

creen represf the buildinged that show

r a particularthe image a

ntrols relatedtrols for the V

t the top rigch allows vie

n shown belohe B zone. om remote snds or until ng call” voice

ercom and the speaker.

ence:

ed) conditionhe flow chartrom green toen will move

e occupancyd the ‘B’ zon

detected, theB’ door to enn, with minimocked, the ‘A

A

D

sents the Sag shown on tw doors either area is occbove is show

d to status aVideo system

ht of the scewing the ins

ow the B doo If a call is station pressthe call req

e message is

voice mess

n is when alt below). Noo red. The pe into the ‘A’ y of the ‘A’ zone, he/she ise ‘A’ door wilnter the facili

mum delays.A’ zone is un

B

C

fety Entrancthe left, and er open or cupied. Also wn with Entr

nd operationm and the In

reen will swspection tray

or symbol alactive, this ses the call quest is acks also playe

ages is con

l four doorste that when

person enterzone (neare

one (middle s screened bll lock, the ‘Bity. This seq Note that thoccupied, an

I N T E R I O R

1

ce structure athe entry lan

closed and loshown is a

ry and Exit lo

n of the Safentercom syst

witch the disy camera.

llows commsymbol will button, the

knowledgeded when the

ntrolled by t

(A-D) are clon a door is loring will openest the outerview). As th

by the metal B’ door will uquence normhe ‘B’ door wnd there is n

1/22/15

and doors, wne shown onocked or unlclock, showock switches

ety Entrancetem.

play to the

unication witurn yellowsymbol will

by pressinsymbol is fla

he small kn

osed, and thocked and bn the ‘A’ door door). A fohe ‘A’ door cdetector in t

unlock (lowemally happenwill not unlocno metal det

with the exten the bottomocked (via

wing the curres hidden.

e, the main

Video

th the w. If a

l flash ng the ashing.

nob on the

he B and D donded, the d

or (which shoootprint symbcloses and ththe center or view), and ns as a smock until the ‘Atector alarm.

erior m.

ent

lower

doors door ows bol he

of the the oth, A’ .

Page 4: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

An exit sentry lanlock and closed. Tlocked . ALERT S There aredescribedas a popcritical on

e 4

equence (noe. Operatiowill not unlo

The ‘D’ door

SCREENS

e six possibd below. Thup at varioune will appea

ot illustratednally, once t

ock until the r will unlock

le alert screehis chart shos locations oar on the scr

) works in ththe ‘C’ zone exit lane is conce the ‘D’

ens that mayows the varioon the screereen first.

he same fashis occupied

completely u’ zone is occ

y appear deous screen een. In the ca

1

hion, and sy and the ‘C’

unoccupied acupied and t

epending on examples. Tase of the bo

1/22/15

ymbols are thdoor closes

and the ‘D’ dhe ‘C’ door i

various conThese indicaottom four al

he same as s, the ‘C’ doodoor has re-is closed an

ditions that aators will apparms, the m

the or will

d

are pear

most

Page 5: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Metal De

This popobject. Tvoice me The operinspectiocan be moverheadThe persmetal is b Optionallmoves bathe operaconsider A box at “Possiblethe electthis occudetected If the sys‘B’ zone, removed If the “AuRefer to

e 5

etected Alar

up will occuThe Alarm poessage at the

rator then inson tray and wmuted with thd video cameson can thenbeing carried

ly, the systeack to the ‘Aator manuallthis configu

the lower lee Tamper”. ronics cabin

urs, contact y.

stem is equipthe Possible before rese

uto Attendanthe section b

rm:

r when someopup has a Re operator c

structs the pwalk back to he “Mute” buera, the ope

n move throud. If no add

m can be coA’ zone. Thisly reset the aration.

ft of the popIn normal opet is detecte

your dealer f

pped with a e Left Objec

etting the me

nt” function isbelow descr

eone movesRed backgroonsole, as w

person (via tthe ‘A’ zone

utton. After ierator will preugh the metaitional metal

onfigured to s option provalarm. Plea

pup area in thperation, thised, this symbfor troublesh

Left Object Dct symbol wiletal alarm.

s enabled, thribing the “Au

s from the ‘Aound, and iswell as a flas

he intercome. If desirednspecting thess the Metaal detector al is detected

automaticavides less sese see your

he Metal Alas will never bbol will be shhooting. The

Detection Syll show on th

he tones anduto Attendan

1

A’ zone to thes accompanishing red ligh

) to place al, the “metal

he contents oal Detected

again to dem, the ‘B’ doo

lly reset wheecurity, but e

r Isotec Deal

arm mode mbe displayedhown and a e alarm cann

ystem and ahe screen. T

d operator ant” operation

1/22/15

e ‘B’ zone caed by a “meht inside the

l metal objecdetected” voof the tray ubutton, rese

monstrate thaor will now un

en the entereliminates thler if you wo

may show thed; however voice messa

not be reset

an object is dThe object s

ctions will ben.

arrying a meetal detectede ‘B’ door.

cts in the oice messagsing the etting the alaat no additionnlock as abo

ing person he need to huld like to

e words if tamperingage will playif tampering

detected in thould be

e different.

etal d”

ge

arm. nal ove.

have

g with y. If g is

he

Page 6: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

System

The Syst

Ois

Td

T T

During Salternateoperator only be cbutton, tu There is messagebe heard SimilarlyThis is tynon-busiMute but Note that

e 6

Override:

tem OverrideOperator deps pressed); The rear pane

isplays a redThe Key SwiThe building

ystem Overe red and gre

console, accancelled byurn the Key

a Mute buttoe. Once the d again the n

, there is a bypically usedness hours, tton, this disa

t during Sys

e Popup Scrpresses the S

el Override d light on thetch on the SFire Alarm s

ride, all dooreen. Systemcompanied resetting whSwitch bac

on located oOverride is

next time Ov

button to disad when the S

and the useabling is can

tem Overrid

reen is displaSystem Ove

Switch (shoe rear panel Safety Entrasystem open

rs are unlocm Override dby a “systemhatever causk on (green

on the popupcleared, theerride occur

able the alteSystem Overer does not wnceled when

e, the metal

ayed wheneerride button

own above)above the snce has beens the conta

ked, and theisplays the p

m unsecure” sed it to occled), or end

p. Pressing te Mute is autrs

ernating red/rride button iwant the lighn the Overrid

detection is

1

ever one of tn on the scre

is moved toswitch) en turned to act across th

e status disppopup screevoice mess

cur (release tthe Fire Ala

this button wtomatically re

/green lightsis used to dihts flashing ade is cleared

s disabled.

1/22/15

he followingeen (this but

o the “up” po

the off posithe fire alarm

plays on the en shown absage. Systemthe Emergearm).

will disable theset, and th

s in the Safetisable the syat that time.

d.

g events occtton will flas

sition (which

tion (red led)input.

Safety Entrabove on the m Override c

ency Releas

he alarm e message w

ty Entrance.ystem during As with the

ur: h if it

h

);

ance

can se

will

g e

Page 7: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Timeout

A Timeoumore tha(default vthese alaA Timeoucause, atA timeouappropria Assistan

This popRequestor will cleaccompa

e 7

t Alarms

ut Popup is dan 45 secondvalue). Thesarms can be ut alarm cant which poin

ut alarm doesate voice me

nce Reques

up is displayt button. It mear automatianied by a “H

displayed onds (default vse default vadisabled, or

n be clearedt a new times not disableessage alert

st

yed if someomay be canccally after a

Help Reques

n the screenvalue) or anyalues are adr can be set , by pressing

eout countdoe any norma.

one outside tcelled by pre

10 second tsted” voice m

n if any zoney door is heldjustable by yto a differen

g the alarm sown will startal system ope

the Safety Essing the Hetimeout. Th

message.

1

e in the Safetd open for myour Isotec Dnt time, fromsymbol, witht if the Safeterations. It

Entrance preelp Requeshe Assistanc

1/22/15

ty Entrance more than 15Dealer. Eith

m the Dealer hout clearingty Entrance is accompan

esses the Asted symbolce Request p

is occupied 5 seconds her or both osetup scree

g the underlyis still occupnied by an

ssistance l on the popupopup is

for

of ens. ying pied.

up,

Page 8: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The Emebutton(s) In normaapproachsystem ain an em(30 secoand ‘D’ d Once thehas beengraph ontime, the At this poremain uThere areconfigure - By the s- Relock shows in- With anconfigura

Once theor the coinformati

e 8

ergency Egr) on the exit

al operation, hes that dooand the ‘D’ dergency, a pnd optional)

doors will be

e Emergencyn initiated, acn the right is

screen showoint, the voicnlocked unte three methed by the de

system consautomatical this case)

n external swation, a mess

e release couonsole operaon on Emerg

ress popup lane.

if the ‘D’ dooor from the inoor does no

person can p time out, duunlocked an

y Egress butccompaniedalso displayws “Emerge

ce message il reset. hods by whicaler during i

sole, using thly 8 seconds

witch, such asage will ap

untdown is iator until the gency Egres

is only show

or is operatinside, and thot unlock corpress an Emuring which and the horn w

tton is pressd by an “Emeyed showingency Release

also change

ch the Emernstallation:

he Clear buts after D doo

as a Keyed Spear informi

nitiated, it cadoor unlock

ss configura

wn if the syst

ng properly,he ‘C’ door isrrectly, or if t

mergency Ega horn will bwill sound co

sed, a popupergency Egrethe time rem

e Activated”es to “Emerg

rgency Egres

tton shown aor being ope

Switch locateng the opera

annot be canks. Please ction options.

1

tem is equip

the ‘D’ doors closed. If there is a neress button.

beep in that lontinuously.

p screen appess Initiatedmaining. At (while the d

gency Egres

ss event can

above ened and the

ed near the ator to opera

ncelled by thcontact your .

1/22/15

pped with em

r will unlock there is somed to unlock. This will stane. After t.

pears, showid” voice mes

the end of tdoors are actss Activated”

n cancelled.

en closed. (

Entrance. Inate the remo

he Safety EnIsotec Deale

mergency eg

when someme failure in tk the whole ltart a 15 secthe delay, th

ing the releasage. A barhe 15 secontually unlock”. The doors

These are

no clear but

n this ote switch.

ntrance occuer for more

gress

eone the lane

cond e ‘C’

ase r nd ked). s will

tton

upant

Graph

Page 9: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Alternaterelease fdescribedthe ‘C’ orexit lane door doethe ‘D’ do When thi Menu Sc The Menscreen pbuttons oAdditionaare usedscreens, the scree (Note: Oaccess toallows se

e 9

e Timed Emfunction, sepd above. Thr ‘D’ door is unlock. Sec

es not unlockoor will unloc

is occurs, th

creen:

nu screen is rovides acce

on the left. Tally, this scre by your deayou can ret

en.

On systems wo the troubleetting the clo

mergency Reparate from there are twoheld open focondly, if sok for some reck automatic

e exit breac

reached by ess to diagnThese screeeen providesaler for initiaurn to the M

with the duaeshooting anock.)

elease: Ththe function

o features to or the Releasmeone becoeason when cally.

hed symbol

pressing theostic and infns provide us access to tl setup, via aain Screen b

l operator cond setup scre

he System cainvoked withthis time relse Time (Deomes disable

the exit lane

will appear

e Next buttonformation scuseful informthe Dealer Ca special paby pressing

onsole optioeens. The r

1

an also be ch the emergelease. If thisefault = 15 seed in the ‘C’e is occupie

on the scree

n on the Macreens via thmation and sConfigurationassword. Fr

the ”Home”

n, the “Slaveright arrow o

1/22/15

configured wency egresss mode is eneconds), botor ‘D’ zone,

ed, after the R

en.

in Screen. The red and wetup featuren Screens wrom each of symbol at th

e” console dn the Slave

with a timed s pushbuttonnabled, if eitth doors in t, and/or the Release Tim

This white es. which

these he lower righ

does not havconsole onl

ns her the ‘D’

me,

ht of

ve y

Page 10: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The Diag

This showdoor posfailed comscreen. words StOK to be

ABANN

The InpuThis brin

e 10

gnostic Scre

ws a graphicsition, occupamponent or If the systemtatic OK shoe displayed:

All doors closB & D doors lA & C doors uNo occupancNo metal dete

ut/Output Ligs up a disp

een is reach

c similar to tancy, and doinstallation p

m inputs are ows in the re

sed; locked and bunlocked an

cy in any zonector alarm.

ist screen isplay of all the

hed by press

he Main Scroor bonded problem. Alsall in the co

ectangle. All

bonded; nd unbondedne;

s reached bye inputs and

sing the ‘Dia

reen. In addsensors. Thso shown is

ondition they l of the follow

d;

y the ‘Input/Ooutputs of t

1

agnostic’ bu

dition, boxesis can be usa rectangleshould be f

wing conditio

Output’ buttthe PLC, for

1/22/15

utton on the O

s indicate theseful in troub on the top r

for the static ons are requ

ton on the Mtroubleshoo

Options scre

e state of thebleshooting aright side of mode, the

uired for Sta

Menu Screenoting purpos

een.

e a the

atic

n. es.

Page 11: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Yellow sqthe “statisignals amight loo The Self button on“Press toSafety Eturns darturn “on”not illumiself test. In order tentry tescycle. The Statthe butto

e 11

quares surroc ok” configu

are off, or othok different t

f Test Screen the screeno start Self Tntrance, eacrk. After a co, that deviceinate is the l

to test the mt. The opera

tistics Screeon brings up

ound the symuration (unoher ones arehan this exa

en allows the and having

Test” button cch device is omplete ent

e has not cycikely failed c

metal detectoator can clea

en allows va table show

mbols for theccupied, all

e on, somethample screen

e operator to someone wclears all thetested, and ry and exit, acled. They scomponent.

or, a Manufaar the metal

iewing variowing various

e signals thadoors close

hing is not opn.)

o start a selfwalk through e prior valueif it is operatall the circleshould illumiThe exampl

cturer’s Tesalarm from

us statisticss event statis

1

at should be ed and lockeperating corr

test processthe entry an

es. As the petional, the sm

es should shonate in ordele below sho

st Piece shouthis same s

s associated stics:

1/22/15

on when thed properly). rectly. (You

s by simply pnd exit laneserson walks mall circle foow “on”. If a

er, so the firsows the scre

uld be carriecreen to com

with the sys

e system is If any of ther actual scre

pressing ones. Pressing through the

or that devicany one doest one that deen at the sta

ed during themplete the e

stem. Press

in ese een

e the

e e

es not oes art of

e entry

sing

Page 12: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page 12 1/22/15

Entry Attempts is the number of times the ‘A’ door has been opened (ie, someone entered the Safety Entrance from the exterior door). This is a different value than the Completed Entries Counter, which is the number of times the ‘B’ door has been opened. Metal Detector Valid Alarms is the number of times the metal detector has gone off when someone is inside the Safety Entrance. MD Alarm per Entry Attempt is the percentage of the entries that resulted in a metal detector alarm. This may be helpful in determining the sensitivity settings on the metal detector. MD Bypass Resets is the number of times that the operator clears a metal detector alarm when the B zone is occupied, letting someone in who may be unscreened. MD Bypass per Valid Alarm is the percentage of the Metal Detector Alarms that are cleared by an MD Bypass event. Completed Entries is the total number of persons that passed through the B door. This counter is separate from the Customer Counter on the Setup screen and is reset along with the other statistics. Aborted Entries is the number of times someone entered the entry lane, and turned around and left via the ‘A’ door. This event would most likely occur when setting off the metal detector alarm, and the person leaving to remove additional metal objects. Metal Detector False Alarms is the count of times the metal detector went off when no one is in the Safety Entrance. A high value here is generally an indication of external noise that should be corrected. Exit Lockdowns is the number of times that the Exit Lock function is invoked by the operator or via the remote switches.

A button is provided on this screen to allow resetting the counters to zero. This button can be enabled or disabled from the Dealer Setup section. Default is enabled. The system can count up to approximately 30,000 events. In order to not display erroneous values, the system will “Auto-Reset” when the entry attempts counter gets to 30,000. A second button is provided to access the Traffic Graph. This graph shows the number of entries versus the time of day.

Page 13: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The data The Setuthe clock

The Conopened. toggled O The Custapproximreset by IS mainta The systethe Alert

e 13

a on this scre

up Screen dk:

sole can be The button

ON and OFF

tomer Countmation of the

pressing theained when

em can alertON/OFF bu

een is reset

deals with th

configured ton the top le

F to enable o

ter totals the number of p

e green Resepower is rem

t the operatoutton enables

using the Re

e customer

to play a voieft of this scor disable th

e number of people that het button locmoved from

or when a sps this alert (t

eset button o

counter and

ce messagecreen (shownis message.

times the ‘Bhave passedcated adjacethe system.

pecified numthe default is

1

on the Statis

d alert, the en

e for the open as “OFF” i. The factory

B’ door has bd thru the syent to the cou

mber of entries OFF). The

1/22/15

stics Screen

ntry alert ton

erator when tn the view ay default is O

been openedystem. This unter indicat

es has occue trigger valu

.

ne, and setti

the ‘A’ door above) can bOFF.

d. This givescounter cantion. This co

rred. Toggliue can be se

ng

is be

s an n be ount

ing et by

Page 14: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

touching the ENT value, the

The Timescreen: Set the tithe SET Screen o Alarm Lowhen the

e 14

the alert vakey on the ke “Customer

e and Date c

ime and dateCLOCK but

or the Home

og brings uey occurred.

lue box, andkeyboard to r Counter” sy

can be set b

e by touchintton to save button to go

p a screen t

d entering thset the new ymbol will fla

y pressing t

ng each field the settingso to the Main

that provides

e new valuevalue into m

ash on the M

he “Set Cloc

and enterin. Press then Screen.

s a historical

1

e on the keybmemory. WhMain Screen

ck” button.

ng the correce Previous b

l record of va

1/22/15

board that when the coun

n

That brings

ct value. Whbutton to retu

arious alarm

will appear. Hnter reaches

up the follow

hen done, prurn to the Se

m indications

Hit s this

wing

ress etup

s and

Page 15: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The Alar Metal Deoccupied

Metal DeEntrance

Possible

Timeoutlong. Th

Overrideabove fo

Emergen

Power U

Exit Trap

MD Bypanormal pthey can The Alarhistory lopages. T The Alarremoved The Revdisplays

e 15

ms that migh

etected – thed.

etect – Falsee is not occu

e Tamper –

t – either thee times for t

e – whenever those cond

ncy Release

Up – time wh

p Invoked –

assed – an rocedure is be rescreen

m Log Screeog. These mTo erase the

m Log Scree.

isions screthe revision

ht be display

e metal dete

e Alarm – thpied.

shows if the

e Safety Entrthese timeou

er one of theditions.)

e – the emer

hen power w

– the Exit Loc

operator hasto have the

ned after put

en has Focumove the focue Alarm Histo

en stores the

een displaysof the softw

yed, and the

ector has de

he metal det

e system thin

rance was outs can be se

override de

rgency relea

was applied to

ck button ha

s cleared a mperson movtting items in

us UP and Fus about oneory, press an

e most recen

s the revisionware loaded

eir meanings

tected a me

tector has de

nks that the e

ccupied too et by your de

evices has be

ase button ha

o the system

as been pres

metal alarm ve back to thn the inspect

Focus DOWe page at a nd Delete A

nt 1000 even

n of the softwin the system

1

s, are as follo

etal object wh

etected a me

electronics c

long or a doealer.

een tripped.

as been pre

m

ssed

when somehe A zone betion tray.

WN buttons fotime. Hold t

All button and

nts, even if t

ware in the Tm processor

1/22/15

ows:

hen the Safe

etal object w

cabinet has

oor has been

(see Syste

essed.

eone was in efore clearin

or scrolling uthe button tod the alarm

the power to

Touchscreenr.

ety Entrance

when the Saf

been opene

n held open

em Override

the B zone. g the alarm,

up and downo scroll multilist will clear

o the system

n and also

e is

fety

ed.

too

The , so

n the iple r.

m is

Page 16: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The Supdealer’s The Useencounte

e 16

port info Scname and p

r Guide Screred in opera

creen displahone will ap

reen provideating the sys

ays contact ippear where

es access tostem. Conte

nformation fthe characte

o short explaents will vary

1

for service oers are in th

nations of thy based on t

1/22/15

on your systeis view:

he more comhe current s

em. Your

mmon topicssoftware.

s

Page 17: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Night Mo If Night Mmain pag

Putting thunlock th Night Mo

e 17

ode:

Mode is enabge:

he system inhe entry lane

ode Off lets t

bled on your

n Night Modee. Night Mod

the entrance

r system, a N

e On will locde also disa

e operate no

Night Mode s

ck the A doorbles the met

rmally.

1

selection bu

r and requiretal detector.

1/22/15

utton will be v

e a card rea

visible on th

der input to

e

Page 18: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

LOCK B Isotec SaTouchscallowed bfeatures The funcare enab

The A DoDoor NoLocked door lock

Note thatbar) will b

e 18

UTTONS

afety Entrancreen, overridby local codeare allowed

ctions availabbled by your

Switches

oor Normalormal indicatis displayed ked with the

t the ‘A’ doobe displayed

ces have theding the norme authorities, & if so, can

ble are Lockdealer, the s

s hidden

and B Dootes that the dwhen the bulower left bu

r button shod as flashing

e option to bmal Safety Es; your Isoten enable tho

k ‘A’ door, Loscreen lock

r Normal budoor locks wutton is toucutton:

ows LOCKEDg red.

be configuredEntrance logec Dealer case desired.

ock ‘B’ doorbuttons will

uttons each work per the ched to lock

D, and also

1

d so that dogic. This lockan assist you

r, and Exit Labe displayed

Sw

lock their resnormal Safethe door. T

that the ‘A’ d

1/22/15

ors can be loking may or

u with determ

ane Lock Ifd as shown

witches disp

spective dooety Entrancehe following

door symbol

ocked from may not be

mining if thes

f these featubelow:

played

or when touce logic; Doorg shows the

l (the red ve

the

se

ures

ched. r ‘A’

rtical

Page 19: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The Exit button is Once ‘C’ remain lois trappethe occu In additiothe ‘B’ dooption fo ‘B’ Door Your syssomeoneas a persmetal alaafter settfor this futhe funct The ‘B’ Dseconds,unlocked The ‘B’ dThis buttlong as t AUTOMA The systeportions in operat

e 19

NORMAL bdepressed, door closes

ocked, rathed until the Epant can lea

on to lockingoor, or both, r you.

r Momentary

tem has thee inside the bson in a whearm. It is NOting off the munction is “ofion. When e

Door Unlock , the ‘B’ doo

d as long as

door unlock” on must be he button is

ATED ATTE

em can be cof the Automtion, a symbo

button on thethen the ‘C’

s with the exr than unloc

Exit Lock buttave via the ‘D

the Exit lanwhen the E

y Unlock

e option to albuilding to e

eelchair whoOT to be usemetal alarm –ff”, so if it is enabled, “ho

is performedr will unlock the button is

can also beheld for 6 seheld.

ENDANT

configured fomated Attendol will appea

e top left ma’ door will re

xit lane occupcking as it woton is toggleD’ door.

ne, the systexit Locked b

low the opeenter the Saf cannot mov

ed to let som– that shouldrequired in y

old to unlock

d by pressin(and the ‘A’

s held.

operated vieconds befo

or ‘Automatedant functionar on the con

ay be used tomain unlockpied, the ‘C’ould in a nored back to N

m can be cobutton is eng

rator to unlofety Entranceve far enoug

meone exit frod be done byyour applicak” will appear

ng and holdin door will loc

a the right bre the door w

ed Attendantn are optionansole screen

1

o detain somked until som door will locrmal exit. Thormal. Onc

onfigured to gaged. Your

ock the ‘B’ doe at that doo

gh through thom the Safey clearing th

ation, please r below the ‘

ng the ‘B’ Dock if it is clos

button on a wwill unlock, a

t’ operation bal. When thn:

1/22/15

meone in themeone entersck, and the ‘hus the occuce the Exit L

also lock eitr dealer can

oor temporaor to assist she metal detety Entrance he metal alar

ask your de‘B’ Lock butt

oor Lock butsed) and wil

wireless remand will stay

by your deale ‘Automate

e exit lane. Is the exit lanD’ door will

upant of the ock is turned

ther the ‘A’ dconfigure th

rily to allow someone, sutector to avovia the ‘B’ d

rm. The deealer to enabton.

tton. After twl remain

mote (see bely unlocked a

ler. Certain ed Attendant

f this ne.

lane d off,

door, his

uch oid a door fault ble

wo

low). as

t’ is

Page 20: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

The ‘Autoconjuncticase of abe install The operdetector,Entrancethe Safetdetected enter. Thmessage If the pervoice mepoint, theinstructio If an “LefEntrancethe consoThe Metaobject is Detector floor, but

After the lock the ‘video moalarm. As part oIf someoremains forward tpeople in

e 20

omated Atteion with the a metal alarmled, and no i

ration is as f they will he

e, remove allty Entrance,in the high z

he console oe during this

rson remainsessage will pe operator wons or resolv

ft Object” (i.e via the ‘A’ dole, alerting al Alarm will detected duAlarm symb

t will also trig

Safety Entra‘A’ door via tonitor or dire

of the ‘Automne enters thin the ‘A’ zothrough the mn this situatio

endant’ featuvoice promp

m, and it is reinspection tr

follows: If anear a voice pl metal objec both doors zone, the moperator will sequence.

s in the ‘B’ zplay at the cowould need tove the situati

e., a weapodoor, after athe operatonot be rese

uring a metalbol. Note thagger if some

ance is empthe ‘A’ Door

ect inspection

mated Attende Safety Enne, after 5 smetal detecton.

ure allows rept option aleecommenderay be instal

n individual erompt that incts, and reenare closed, etal alarm issee the me

one after theonsole, alerto contact theon.

n) is detecte few secondr that somett automatical alarm, a waat the Left oone is still s

pty and a Lefbutton, eval

n, and remo

dant feature trance and reconds, a votor. This elim

duced operarting the occ

ed that the ‘Bled.

enters the enstructs themnter the Safeand no occu

s automaticatal detector

e voice proming the opere occupant v

ed in the ‘B’ds, the “Metathing has beally if a left oarning text bbject detectotanding in th

ft Object alaluate what isve the offen

set, a seconremains in thoice promptminates the

1

ator workloacupant as to B’ Zone Left

ntry lane anm to turn aroety Entranceupancy is deally cleared,alarm popup

mpt for 10 serator that actvia intercom

zone after aal Detected” een left behinobject has bebox is displayor will not onhe ‘B’ zone.

arm occurs, ts left in the Sding object

nd voice prohe A zone, ois played terequirement

1/22/15

ad. It shouldwhat actionObject Dete

d triggers thound, exit the. Once the etected, and allowing thep, but will no

econds, the “tion is requirto provide f

a person exitvoice mess

nd and actioeen detectedyed adjacennly detect ob

the operatorSafety Entrabefore clear

mpt in the laor two peoplelling the pert for an oper

d only be usen to take in thection option

he metal e Safety individual eno objects a

e next personot hear any v

“Metal Detecred. At this further

ts the Safetyage will play

on is requiredd. When a lent to the Metabjects on the

r should manance via the ring the meta

ane is availae enter and rson to moverator to direc

ed in he n also

exits are n to voice

cted”

y y on d. eft al e

nually

al

able. one

e ct

Page 21: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page 21 1/22/15

CREDENTIAL RESET: As a further method to reduce operator workload, the Safety Entrance also has the capability to be outfitted with a Credential system (card reader/pin device and/or biometric reader) that can be configured to allow a person entering the Safety Entrance who set off the metal detector to clear the metal alarm by presenting their credentials. These credentials would of course only be given to “trusted” individuals who the facility wishes to enter the facility with metal objects. The operation requires no action on the part of the system operator; the entrant simply presents the credential after passing through the metal detector (if an alarm is triggered). The Alarm resets and the person can continue through the Safety Entrance. This system is often utilized in conjunction with the Automated Attendant feature to reduce operator interaction to almost zero. REMOTE TRANSMITTERS: Isotec offers the options of either single or two button remote control transmitters, which allow certain functions to be implemented without having to go to the operator console. This might be useful for other officers in the bank to operate the system in parallel with the console operator. The Single Button Remote, or the top left button on a Multi-Button Remote, is used to clear the metal detector alarm. Depressing that button and holding it for 1 second (to prevent inadvertent presses) ends the alarm immediately. At that point, the Safety Entrance will work normally (for example, the B door will unlock if all the normal logic conditions are met) On the two button remote option, the right button function is programmable by your Isotec Dealer. The functions available are:

‘A’ door Lock ‘B’ door Lock Entry Lock (both ‘A’ and ‘B’ doors locked) Exit Lock (same operation as the Exit lock on the Touchscreen) Release All (same function as depressing the Override button on the console – releases

all doors.) In the case of the first four functions, the operation of the button is “alternate action” – in other words, the first press turns on the function (hold for 1 second – a flashing red light indicates the remote has triggered and you can release the button), and the second press turns off the function. Note that if one transmitter is used to turn on the function, either that transmitter or another transmitter can be used to turn off the function. There is an indicator on the Operator Console that shows when the function is toggled “ON” as shown by the words “Remote On” on the screen example below. Note also the purple rectangle next to the ‘A’ door lock symbol, indicating that is what the remote is controlling:

Page 22: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

In the cadoes not Release release. will only release. button on Similar to‘B unlockto unlockdepresseas the buflashing a“Disabled Third Rebutton. Tused for to lock, pOn will a EXTERN The systeunlock vaThese ininputs av ‘A’ door C‘B’ door CExit Lane

e 22

se of the Relatch as theAll functionThis button

hold the dooIf the system

n the Operat

o the ‘B’ dooks after hold k the ‘B’ dooed for 6 secoutton continuafter about 3d”.

emote ButtoThis button ianother func

press to unlolso show wh

NAL CARD I

em has the carious doorsputs could b

vailable are:

Card in Card in e Unlock in

elease All fue other funct, this button must then b

ors open for m needs to btor Console.

or touchscree6 seconds’ r as well. Wonds, to avoues to be he3 seconds of

on: Isotec sys hard wiredction beside

ock (as with then this butto

NPUTS:

capability tos or lanes. Tbe used for e

unction, the rions do). In must be he

be held dowabout 10 sebe overridde

en button, if setting is en

When using thid inadverteld. Note thaf pressing. T

ystems, stard as a ‘’B’ Dos ‘B’ Door Lthe other buon is active,

be wired to This would bexternal card

remote buttoorder to pre

eld depressen to keep th

econds and ien for a long

the “Unlocknabled, the rhe remote tont unlocking

at the red indThe default f

rting with sofoor Lock’ funock. This buttons, you mas will the s

one or moree wired by yd readers or

1

on acts as a eclude inadved for 1.5 sece doors reles only intend

ger time perio

k B” remote fright button oo unlock the g. The door dicator light ofor the “unlo

ftware rev Hnction. Thisutton is Alte

must hold it osmall diamon

e external coyour dealer a

as a remote

1/22/15

momentaryvertent operaconds before

eased. Holdded for a temod, use the O

function is seon the remot‘B’ door, thewill remain uon the remo

ock after hold

Hr2, can haves allows the 2rnate Action

on for 1 second by the ‘B

ontacts that as part of thee “override” c

push buttonation of the e the doors ing this buttomporary dooOVERRIDE

elected, andte can be use button musunlocked as

ote will stop d-remote” is

e a third rem2nd button to

n as well – prond). Remo’ door.

can be usede installationcapability. T

n (it

on or

d the sed st be long

mote o be ress te

d to n. The

Page 23: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Each of tcontact foSimilarly to multipthe whole When onthe input

If both thalarm is t ANTI-TA If your sydifferent.determinwill not oOccupan Also, if thsame are

e 23

these inputsor the ‘’A’ dofor the othele inputs in pe entry lane.

ne of these ins is on:

e ‘’A’ door uturned off un

AILGATING

ystem is equ In the entrye if more tha

open. When ncy symbol.

he ATG systea as the me

uses a dry oor Card in’ er two inputsparallel. For.

nputs is activ

unlock’ and tntil either or

SYSTEM

uipped with Ay lane, whenan one persothe ATG de

em is triggeetal detector

contact closunlocks the . To unlock r example, w

ve, a symbo

he ‘’B’ door both of the s

Anti-Tailgatinn the occupaon is detecte

etectors are t

red after ther alarms, and

sure input to ‘A’ door, demultiple doo

wiring the ‘A’

ol shows on t

unlock’ switcswitches reo

ng (ATG) deant approached. If multiptriggered, a

e B door unlod will need to

1

activate thepending on ors, the exte and ‘B’ card

the main scr

ches are cloopen.

etectors, the hes the B do

ple occupantsmall yellow

ocks, an ATGo be cleared

1/22/15

e function. Cthe configur

ernal contactd input’s tog

reen indicati

osed, the me

operation isoor, the ATGts are detectw box will ap

G Alarm willd by pressing

Closing the ration settingt(s) can be w

gether unlock

ing that one

etal detector

s slightly G system willted, the B do

ppear near th

pop up in thg the alarm

gs. wired ks

of

r

l oor he B

he box.

Page 24: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Multiple

Synergy operatesconsole cdone by takes theScreen fostation.

The Masto providthe main informati The ‘Off ‘Off Line’volume cstation. Sdisplay. intercom

e 24

Console (M

is available s as alternatecan be in cotouching the

e other consoor the Slave

ter console e access to control scre

on is access

Line’ consol’. If these alcontrol. WheSimilarly, if tOnly the ‘Onand video f

Master-Slave

with a dual e or ‘slave’ o

ontrol of the se ”Enable Thole ‘Off Line console is s

has the ‘Nexthe various

een, and hassed using th

e will providerts are not

en an alarm the portal is n Line’ statiounctions.

e) Option:

console optioperator statsystem at a his Console” e’ and bringsshown above

xt’ button onsetup and d

s no “Next” be Master sta

de audio alerdesired, theoccurs, a flain a ‘System

on can deal w

ion, which ption. The optime. Switc button on t

s control to the; the Offlin

n the lower ridata options.button and nation.

rts when alae volume on ashing ‘Alert

m Override’ cwith these a

1

rovides a seperation is “ohing from onthe current ‘Ohe enabled cne Screen is

ight corner o. The Slave no clock disp

rm events othat station

t Active’ iconcondition, a alerts, contro

1/22/15

econd Synerone at a timene console tOff Line’ conconsole. Thsimilar on th

of the Main oconsole onl

play. All setu

occur, even ifcan be turn

n will show o‘System Ove

ol the portal,

rgy console te” – only oneto the other insole, whichhe Off Line he Master

operator screly allows useup and data

f the station ed down wit

on the ‘Off Lierride’ icon wand utilize t

that e is

h

een e of

is th the ine’ will the

Page 25: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page

Physica The oper

R

SystemSwitch and

DC P

e 25

l User Interf

rator console

InternMicropho

Remote ReceiStatus Lig

m Override d Indicator

Power Input

Et(if equ

face:

e has a few

nal ne

iver ghts

thernet uipped)

physical con

Aler

ntrols that m

Video In

rt and IntercoBalance

1

may be neede

Speake

n

om

1/22/15

ed, as follow

Touchs

r

MasterVolume

ws:

screen

r e

Volume Balance (see below)

InterconnectiCables

on

Page 26: IsotecSec SYNERGY USER Manual 1-22-15 · 1 ion, and sy and the ‘C’ noccupied a upied and t epending on xamples. T se of the bo /22/15 mbols are th door closes nd the ‘D’ d

page 26 1/22/15

The Alert and Intercom Balance controls allow the adjustment of the relative volume between the Alerts that sound when an alarm occurs, and the incoming intercom station sound level. The default is to have the two potentiometers set at roughly 2/3rds clockwise. Using a small flat blade screwdriver, turn down one or the other if you desire that sound to be relatively less than the other. The Main Volume on the front panel adjusts both together.