JDSU T-BERD 6000A RFC-2544 Ethernet
Testing Guide
Version 1.0 December 19, 2011
Page 2 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
Table of Contents Scope ......................................................................................................................................................... 2
Revision History ....................................................................................................................................... 2
1. Overview ........................................................................................................................................... 3
1.1 Hardware Description ................................................................................................................ 3
2. RFC-2544 Test Procedures ............................................................................................................... 4
2.1 T-BERD 6000A RFC-2544 test ................................................................................................. 5
2.2 T-BERD 6000A Loopback ...................................................................................................... 11
2.3 T-BERD 5800 Loopback ......................................................................................................... 14
2.4 HST-3000 Loopback ................................................................................................................ 17
3. RFC-6349 Test Procedures ............................................................................................................. 21
3.1 JDSU T-BERD 6000A RFC-6349 TCP Throughput Test ....................................................... 22
3.2 JDSU T-BERD 6000A TCP Server setup ................................................................................ 27
Scope
This document covers Ethernet testing procedures used for Business Services customer activation,
fault isolation, and troubleshooting using the JDSU T-BERD 6000A portable business services tester.
This document provides procedures for Metro Ethernet service up to 1 Gbps, including:
Layer 2 and Layer 3 IPv4 RFC-2544 tests between two T-BERD 6000A’s
Layer 2 and Layer 3 IPv4 RFC-2544 tests between the T-BERD 6000A and T-BERD 5800
Layer 2 and Layer 3 IPv4 RFC-2544 tests between the T-BERD 6000A and HST-3000
Layer 4 RFC-6349 TCP Throughout tests between two T-BERD 6000A’s.
RFC-2544 is a recommended test suite for verifying key performance indicators or Metro Ethernet
service with a single class of service
RFC-6349 is a recommended test suit for verification of TCP Throughput on Metro Ethernet networks.
This document mandates proper care, cleaning, inspection, and handling of fiber optic connectors. All
fibers and connectors must be cleaned and inspected when service is turned up on these fibers and
whenever a fiber is disconnected and reconnected.
Revision History
Revision Description Name
1.0 Initial Draft Dave Baker, JDSU
Page 3 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
1. Overview
This document covers Ethernet testing procedures used for Business Services customer activation,
fault isolation and troubleshooting. At customer activation, test equipment is used to validate the
performance of an Ethernet circuit and to verify conformance to the agreed upon Service Level
Agreement (SLA).
1.1 Hardware Description
The T-BERD 6000A is a portable test tools for Ethernet testing. The product comes in Ethernet only
or Ethernet/T1/T3/SONET variations and works in conjunction with a fiber cleaning and inspection kit
to help turn-up and maintain Ethernet links. Menu selections are made from the T-BERD 6000A front
panel and touch screen.
T-BERD 6000A Front Panel:
Page 4 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2. RFC-2544 Test Procedures
The following procedures describe how to measure throughput, frame loss, round trip delay, and jitter
with the T-BERD 6000A in accordance with the RFC-2544 Metro Ethernet benchmarking
methodology.
Test procedures are described for:
Electrical and Optical handoffs
10Mbps, 100Mbps, and 1Gbps links
Layer 2 and Layer 3 IPv4 testing
JDSU T-BERD 6000A, T-BERD 5800, and HST-3000 loopback devices
Procedures are described for RFC-2544 Tests to verify throughput, round trip delay, jitter, and frame
loss SLA metrics. Technicians should follow procedure in one of the following sections, depending on
his location (A-side or Z-side) and whether he is using a T-BERD 6000A, T-BERD 5800, or HST-
3000 test equipment. The RFC-2544 test is run from the A-Side. The Z-side is placed in loopback.
Meter A-Side Z-Side
T-BERD 6000A Section 2.1 Section 2.2
T-BERD 5800 Not applicable Section 2.3
HST-300 Not applicable Section 2.4
Page 5 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2.1 T-BERD 6000A RFC-2544 test
Use this procedure to set up a TBERD 6000A to test a 10Mbps, 100Mbps, or 1000Mbps link.
Step Action Details
1. Install PIM Install the SFP Physical Interface Module (PIM) in the T-BERD 6000A.
2. Insert SFP Insert desired SFP (1000BASE-TX, 1000BASE-SX, 1000BASE-LX, or
1000BASE-ZX) in the MSAM’s SFP PIM.
3. Power On Press the ON/OFF button to turn on the T-BERD 6000A. Wait
approximately 1 minute for the Base Unit software to load.
4. Launch MSAM Press the SYSTEM button. The MSAM is represented by a BERT icon
on the upper image of the test set. If the BERT icon is not already
highlighted in yellow, tap the icon twice to start the application. The
icon should be yellow with a green border.
5. View Results Press the RESULTS button to watch the progress of the BERT Module
startup.
6. Clean & Inspect While the BERT module is starting up, and before connecting to an
optical link, make sure the fiber and connector are clean using a Fiber
Inspection probe.
7. Connect Connect the SFP on the T-BERD 6000A to the Ethernet switch port.
Use Orange Multimode jumper cables for 850 nm 1000BASE-SX.
Page 6 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
Use Yellow Single Mode Fiber jumper cables for 1310 nm
1000BASE-LX and 1550 nm1000BASE-ZX.
Use CAT 5E or better cable for copper 1000BASE-TX connections
8. Select Test In the Test menu, select one of the following:
For Layer 2 Electrical (Copper) Testing:
Ethernet>10/100/1000>Layer 2 Traffic> Terminate.
For Layer 2 Optical Testing:
Ethernet>1GigE Optical>Layer 2 Traffic> Terminate.
For Layer 3 IPv4 Electrical Testing:
Ethernet>10/100/1000>Layer 3 Traffic> IPv4>Terminate.
For Layer 3 IPv4 Optical Testing:
Ethernet>1GigE Optical>Layer 3 Traffic> IPv4>Terminate.
9. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
10. Setup Press the SETUP soft key on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other
values at default, unless specified in the Work Order. Folder Option Value(s) Comment
Interface,
Connector
Electrical
Connector SFP1 or SFP2
For Electrical tests, select
ETHERNET 1000BASE-T SFP
Interface,
Connector
Optical
Connector SFP1 or SFP2
For Optical tests, select desired optical
SFP (1000BASE-SX, 1000BASE-LX,
etc.)
Interface,
Physical
Layer
Auto
Negotiation See Work Order Set to same value as Ethernet switch port.
Duplex See Work Order
Options only displayed if Auto Negotiate
= Off Speed
Ethernet
Encapsulation See Work Order None or VLAN
VLAN ID See Work Order Options displayed after tapping VLAN
field if Encapsulation = VLAN
Page 7 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
For Layer 3 IPv4 testing, configure the following additional settings: Folder Option Value(s) Comment
IP
Source IP Type Static
Options displayed after tapping
Source IP Address field.
Source IP See Work Order
Default Gateway See Work Order
Subnet Mask See Work Order
Destination IP See Work Order Options displayed after tapping
Destination IP Address field.
11. View Results Press the RESULTS button, to display the Results screen.
12. Turn Laser On If testing an Optical link, select the Laser tab in the lower part of the
screen and press Laser Off. The button will turn Yellow and be
relabeled to indicate the Laser is On.
13. Check LEDs Press the Restart soft key on the Right side of the display to reset test
results. A Green Signal Present LED indicates that the T-BERD is
receiving an optical signal from the near end Ethernet Switch. Green
Sync Acquired and Link Active LEDs indicate that the T-BERD has
successfully connected to the near end Ethernet switch and the Ethernet
link is active.
14. Check ARP Status If you are running a Layer 3 IPv4 Test, verify that the final message in
the Message bar is “ARP Successful. Destination MAC obtained.” If
the message bar displays: “Messages logged,” tap the down arrow next
to “Messages logged” and verify that the final message is “ARP
Successful. Destination MAC obtained.” Click OK to exit the log.
If “ARP Successful” is not displayed, verify that the T-BERD’s IP menu
is configured correctly, as outlined above.
15. Start RFC Press the Enhanced RFC 2544 soft key on the Right side of the Results
screen.
16. Select Config Select the Configs tab. If this is the first time using the RFC2544 test,
tap [New], enter a name for the new configuration, then tap [OK].
Otherwise, choose the saved Test Configuration.
Page 8 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
17. Setup Select the indicated folders and configure your test as follows:
Folder Option Value(s) Comment
Symmetry Symmetric
Setup,
All Tests
Tests Throughput, Latency,
Packet Jitter, Frame Loss
Frame or Packet Frame
Option only
displayed if test =
Layer 3 IPv4
Frame Lengths to Test 64 and 1518 if no VLAN
68 and 1522 if VLAN
If the MTU is
greater than 1518
or 1522 w/ VLAN,
also select one
User Selected
frame length and
enter the MTU
Maximum Bandwidth See Work Order for CIR
Load Format Mbps
Setup,
Throughput
Measurement Accuracy (%) To within 1.0 Mbps
Zero-in Process JDSU Enhanced
Trial Duration (seconds) 60
Frame Loss Tolerance (%) 0
Show Pass/Fail Status Selected
Throughput Threshold
(Mbps) See Work Order for CIR
Setup,
Latency
(RTD)
Number of Trials 1
Trial Durations (seconds) 60
Show Pass/Fail Status
Select for VoIP, IPTV,
Circuit Emulation, or
Cell Backhaul service
Latency Threshold (µsec) See Work Order
If not specified:
250,000 for VoIP
250,000 for IPTV
50,000 for Circuit
Emulation
20,000 for Mobile
Backhaul
Setup,
Packet
Jitter
Number of Trials 1
Trial Durations (seconds) 60
Show Pass/Fail Status
Select for VoIP, IPTV,
Circuit Emulation, or
Cell Backhaul service
Packet Jitter Threshold (µs) See Work Order
If not specified:
40,000 for VoIP
250,000 for IPTV
20,000 for Circuit
Emulation
3,000 for Mobile
Backhaul
Setup,
Frame Loss
Test Procedure RFC 2544
Trial Durations (seconds) 60
Bandwidth Granularity (%) 1Mbps
Page 9 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
18. Run QuickCheck Ensure that the Z-side loopback device has been setup, then select the
J-QuickCheck tab, and tap [Run J-QuickCheck] to verify local and
remote test connectivity and available bandwidth.
19. Run RFC 2544 Tap [Run RFC 2544 Test]. The T-BERD will loop up the far end unit,
and test Throughput, Delay, Jitter, and Frame Loss. The test will take 6
to 9 minutes to complete. At the conclusion of the test, the T-BERD
6000A will automatically loop down the far end JDSU loopback device.
20. Save Results At the conclusion of the test, enter Customer name, Technician Name,
Test Location, and Comments at the prompt. Select the Append option,
and tap [Yes] to save the test report to the T-BERD 6000A hard drive in
PDF format. The filename, including a time and date stamp, will be
displayed in the Progress log.
Page 10 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
21. View Summary Select the Summary tab to view status of all tests. Verify that all tests
PASS and the displayed values meet the performance objectives of the
line under test.
22. Exit Tap [Exit] to return to the main Results view.
23. RFC-6349 If the Z-side test equipment is a T-BERD 6000A and both units are
equipped with the LAYER4 TCP Wirespeed option, proceed to section 3.
Page 11 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2.2 T-BERD 6000A Loopback
Use this procedure to set up a T-BERD 6000A as a far-end (Z-side) loopback device.
Step Action Details
1. Install PIM Install the SFP Physical Interface Module (PIM) in the T-BERD 6000A.
2. Insert SFP Insert desired SFP (1000BASE-TX, 1000BASE-SX, 1000BASE-LX, or
1000BASE-ZX) in the MSAM’s SFP PIM.
3. Power On Press the ON/OFF button to turn on the T-BERD 6000A. Wait
approximately 1 minute for the Base Unit software to load.
4. Launch MSAM Press the SYSTEM button. The MSAM is represented by a BERT icon
on the upper image of the test set. If the BERT icon is not already
highlighted in yellow, tap the icon twice to start the application. The
icon should be yellow with a green border.
5. View Results Press the RESULTS button to watch the progress of the BERT Module
startup.
6. Clean & Inspect While the BERT module is starting up, and before connecting to an
optical link, make sure the fiber and connector are clean using a Fiber
Inspection probe.
7. Connect Connect the SFP on the T-BERD 6000A to the Ethernet switch port.
Use Orange Multimode jumper cables for 850 nm 1000BASE-SX.
Page 12 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
Use Yellow Single Mode Fiber jumper cables for 1310 nm
1000BASE-LX and 1550 nm1000BASE-ZX.
Use CAT 5E or better cable for copper 1000BASE-TX connections
8. Select Test In the Test menu, select one of the following:
For Layer 2 Electrical (Copper) Testing:
Ethernet>10/100/1000>Layer 2 Traffic> Terminate.
For Layer 2 Optical Testing:
Ethernet>1GigE Optical>Layer 2 Traffic> Terminate.
For Layer 3 IPv4 Electrical Testing:
Ethernet>10/100/1000>Layer 3 Traffic> IPv4>Terminate.
For Layer 3 IPv4 Optical Testing:
Ethernet>1GigE Optical>Layer 3 Traffic> IPv4>Terminate.
9. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
10. Setup Press the SETUP soft key on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other
values at default, unless specified in the Work Order. Folder Option Value(s) Comment
Interface,
Connector
Electrical
Connector SFP1 or SFP2
For Electrical tests, select
ETHERNET 1000BASE-T SFP
Interface,
Connector
Optical
Connector SFP1 or SFP2
For Optical tests, select desired optical
SFP (1000BASE-SX, 1000BASE-LX,
etc.)
Interface,
Physical
Layer
Auto
Negotiation See Work Order Set to same value as Ethernet switch port.
Duplex See Work Order
Options only displayed if Auto Negotiate
= Off Speed
Page 13 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
For Layer 3 IPv4 testing, configure the following additional settings: Folder Option Value(s) Comment
IP
Source IP Type Static
Options displayed after tapping
Source IP Address field.
Source IP See Work Order
Default Gateway See Work Order
Subnet Mask See Work Order
Destination IP See Work Order Options displayed after tapping
Destination IP Address field.
11. View Results Press the RESULTS button, to display the Results screen.
12. Turn Laser On If testing an Optical link, select the Laser tab in the lower part of the
screen and press Laser Off. The button will turn Yellow and be
relabeled to indicate the Laser is On.
13. Check LEDs Press the Restart soft key on the Right side of the display to reset test
results. A Green Signal Present LED indicates that the T-BERD is
receiving an optical signal from the near end Ethernet Switch. Green
Sync Acquired and Link Active LEDs indicate that the T-BERD has
successfully connected to the near end Ethernet switch and the Ethernet
link is active.
14. Check ARP Status If you are running a Layer 3 IPv4 Test, verify that the final message in
the Message bar is “ARP Successful. Destination MAC obtained.” If
the message bar displays: “Messages logged,” tap the down arrow next
to “Messages logged” and verify that the final message is “ARP
Successful. Destination MAC obtained.” Click OK to exit the log.
If “ARP Successful” is not displayed, verify that the T-BERD’s IP menu
is configured correctly, as outlined above.
15. Test Inform the A-side technician that you are ready for test.
16. Run RFC-6349 If the A-side and Z-side test equipment are both equipped with the
LAYER4 TCP Wirespeed option, proceed to section 3.
Page 14 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2.3 T-BERD 5800 Loopback
Use this procedure to set up a T-BERD 5800 as a far-end (Z-side) loopback device.
Step Action Details
1. Power On Press the ON/OFF button to turn on the T-BERD 5800. Wait
approximately 2 minutes for the Base Unit software to load.
2. Insert SFP For optical testing, insert desired SFP (1000BASE-SX, 1000BASE-LX,
or 1000BASE-ZX) in the desired T-BERD 5800’s SFP port.
3. Clean & Inspect While the BERT module is starting up, and before connecting to an
optical link, make sure the fiber and connector are clean using a Fiber
Inspection probe.
4. Connect Connect the Ethernet test port on the top of T-BERD 5800 to the
Ethernet switch port under test.
Use Orange Multimode jumper cables for 850 nm 1000BASE-SX.
Use Yellow Single Mode Fiber jumper cables for 1310 nm
1000BASE-LX and 1550 nm1000BASE-ZX.
Use CAT 5E or better cable for copper 1000BASE-TX connections
Page 15 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
5. Select Test In the Test menu, select one of the following:
For Layer 2 Electrical (Copper) Testing:
Ethernet>10/100/1000>Layer 2 Traffic> Terminate.
For Layer 2 Optical Testing:
Ethernet>1GigE Optical>Layer 2 Traffic> Terminate.
For Layer 3 IPv4 Electrical Testing:
Ethernet>10/100/1000>Layer 3 Traffic> IPv4>Terminate.
For Layer 3 IPv4 Optical Testing:
Ethernet>1GigE Optical>Layer 3 Traffic> IPv4>Terminate.
6. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
7. Setup Press the SETUP soft key on the top right side of screen. Select the
indicated folders and configure your test as follows. Leave all other
values at default, unless specified in the Work Order. Folder Option Value(s) Comment
Interface,
Physical
Layer
Auto
Negotiation See Work Order Set to same value as Ethernet switch port.
Duplex See Work Order
Options only displayed if Auto Negotiate
= Off Speed
For Layer 3 IPv4 testing, configure the following additional settings: Folder Option Value(s) Comment
IP
Source IP Type Static
Options displayed after tapping
Source IP Address field.
Source IP See Work Order
Default Gateway See Work Order
Subnet Mask See Work Order
Destination IP See Work Order Options displayed after tapping
Destination IP Address field.
8. View Results Press the RESULTS soft key, to display the Results screen.
Page 16 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
9. Turn Laser On If testing an Optical link, select the Laser tab in the lower part of the
screen and press Laser Off. The button will turn Yellow and be
relabeled to indicate the Laser is On.
10. Check LEDs Press the Restart soft key on the Right side of the display to reset test
results. A Green Signal Present LED indicates that the T-BERD is
receiving an optical signal from the near end Ethernet Switch. Green
Sync Acquired and Link Active LEDs indicate that the T-BERD has
successfully connected to the near end Ethernet switch and the Ethernet
link is active.
11. Check ARP Status If you are running a Layer 3 IPv4 Test, verify that the final message in
the Message bar is “ARP Successful. Destination MAC obtained.” If
the message bar displays: “Messages logged,” tap the down arrow next
to “Messages logged” and verify that the final message is “ARP
Successful. Destination MAC obtained.” Click OK to exit the log.
If “ARP Successful” is not displayed, verify that the T-BERD’s IP menu
is configured correctly, as outlined above.
12. Test Inform the A-side technician that you are ready for test.
Page 17 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2.4 HST-3000 Loopback
Use this procedure to set up an HST-3000 as a far-end Z-side loopback device.
Step Action Details
1. Install SIM Install Ethernet Module on the HST-3000.
2. Power On Press the green Power Key to turn on the HST-3000. Wait
approximately 25 seconds for the Base Unit software to load.
3. Insert SFP For optical testing, insert desired SFP (1000BASE-SX, 1000BASE-LX,
or 1000BASE-ZX) into the optical SFP connector labeled R/T 1.
4. Clean & Inspect While the BERT module is starting up, and before connecting to an
optical link, make sure the fiber and connector are clean using a Fiber
Inspection probe.
5. Connect Connect the Ethernet test port to the Ethernet switch port under test.
Use Orange Multimode jumper cables for 850 nm 1000BASE-SX.
Use Yellow Single Mode Fiber jumper cables for 1310 nm
1000BASE-LX and 1550 nm1000BASE-ZX.
Use CAT 5E or better cable for copper 1000BASE-TX connections
Page 18 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
6. Launch Test App Launch test application as follows:
For Layer 2 Electrical (Copper) Testing, press the ETH ELEC Soft
key, select Terminate, and press the OK key. Select Layer 2
Traffic at the Test prompt
For Layer 2 Optical Testing, press the ETH OPTIC Soft key, select
1G Terminate, and press the OK key. Select Layer 2 Traffic at the
Test prompt
For Layer 3 IPv4 Electrical (Copper) Testing, press the ETH ELEC
Soft key, select Terminate, and press the OK key. Select Layer 3 IP
Traffic at the Test prompt
For Layer 3 IPv4 Optical Testing, press the ETH OPTIC Soft key,
select 1G Terminate, and press the OK key. Select Layer 3 IP
Traffic at the Test prompt.
Page 19 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
7. Configure Test Press the Configure Navigation key to configure test setting. Using the
Right Arrow key or Settings soft key, scroll through Settings menus
and configure your test as follows. Leave all other values at default,
unless specified in the Work Order.
For Layer 2 Testing:
For Layer 3 IP Testing:
8. View Results Press the Home key to display Summary Results.
9. Turn Laser On For optical testing, press the Action soft key and select Laser On.
10. Restart Press the Restart soft key to reset test results.
11. Check LED Results Press the Right Arrow key until LED Results are displayed. A Green
Signal Present LED indicates that the HST-3000 is receiving an optical
signal from the near end Ethernet Switch. Green Sync Acquired and
Link Active LEDs indicate that the HST-3000 has successfully
connected to the near end Ethernet switch and the Ethernet link is active.
Menu Option Value Comment
Test Mode Test Layer 2 Traffic .
RFC 2544 Mode Disable
Link Init
Auto Negotiation See Work Order Set to same values as
Ethernet switch port. Speed See Work Order
Duplex Full
Menu Option Value Comment
Test Mode Test Layer 3 IP Traffic .
RFC 2544 Mode Disable
Link Init
Auto Negotiation See Work Order Set to same values as
Ethernet switch port. Speed See Work Order
Duplex Full
IP Init
ARP Mode Disable
Source Type Static IP
Source IP See Work Order
Subnet Mask See Work Order
Default Gateway See Work Order
Page 20 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
12. Check ARP Status If you are running a Layer 3 IPv4 Test, verify that the final message in
the Message bar is “ARP Successful”
If “ARP Successful” is not displayed, verify that the HST-3000’s IP
menu is configured correctly, as outlined above.
13. Test Inform the A-side technician that you are ready for test.
Page 21 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
3. RFC-6349 Test Procedures
The following procedures describe how to measure Layer 4 TCP throughput with the T-BERD 6000A
in accordance with the RFC-6349 benchmarking methodology. The RFC-2544 procedure outlined in
Section 2 should be completed prior to RFC-6349 testing.
Test procedures are described for:
Electrical and Optical handoffs
10Mbps, 100Mbps, and 1Gbps links
Technicians should follow procedure in one of the following sections, depending on his location (A
side or Z side). The RFC-6349 test is run from the A-Side. The Z-side is configured as a TCP Server.
Meter A-Side Z-Side
T-BERD 6000A Section 3.1 Section 3.2
Page 22 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
3.1 JDSU T-BERD 6000A RFC-6349 TCP Throughput Test
Use this procedure to set up a T-BERD 6000A to test TCP Throughput.
Step Action Details
1. Select Test For electrical handoffs: In the Test menu at the top of the Results screen,
and select Ethernet>10/100/1000>Layer 4 TCP Wirespeed>
IPv4>Terminate.
For optical handoffs: In the Test menu at the top of the Results screen,
and select Ethernet>1GigE Optical>Layer 4 TCP Wirespeed>
IPv4>Terminate.
Page 23 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
3. Setup Press the SETUP soft key on the top right side of screen.
For Electrical handoffs: Select the indicated folders and configure your
test as follows. Folder Option Value(s) Comment
Interface,
Connector Electrical Connector
SFP1 or
SFP2
Select
ETHERNET 1000BASE-T SFP
Interface,
Physical Layer
Auto Negotiation See Work
Order
Set to same value as Ethernet
switch port.
Duplex See Work
Order
Options only displayed if Auto
Negotiate = Off Speed
For Optical handoffs: Select the indicated folders and configure your
test as follows. Folder Option Value(s) Comment
Interface,
Connector Optical Connector
SFP1 or
SFP2
Select desired optical SFP
(1000BASE-SX, 1000BASE-LX,
etc.)
Interface,
Physical Layer Auto Negotiation
See Work
Order
Set to same value as Ethernet
switch port.
Leave all other values at default, unless specified in the Work Order.
4. View Results Press the RESULTS button, to display the Results screen.
5. Start TrueSpeed Press the TrueSpeed Test soft key.
6. Select Config Select the Configs tab. If this is the first time using the RFC2544 test,
tap [New], enter a name for the new configuration, then tap [OK].
Otherwise, choose the saved Test Configuration.
Page 24 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
7. Setup Select the Setup tab, select the indicated folders, and configure your test
as follows: Folder Option Value(s) Comment
Setup,
All Steps
Steps RTT only
Bottleneck
Bandwidth (Mbps) See Work Order for CIR
Connect to Server See Work Order For Layer 2 handoffs,
set to 192.168.1.3
Type of Service See Work Order For Layer 2 handoffs,
set to None
Connect to Port 5001
Source IP Type Static
Source IP See Work Order For Layer 2 handoffs,
set to 192.168.1.2
Default Gateway See Work Order For Layer 2 handoffs,
set to 192,168.1.1
Subnet Mask See Work Order For Layer 2 handoffs,
set to 255.255.255.0
Encapsulation See Work Order None or VLAN.
Setup, RTT Duration (seconds) 10
8. Run RTT Scan Ensure that the Z-side has been setup as a TCP Server, then tap
[Run TrueSpeed Test] at the bottom of the screen. The T-BERD will
measure the Baseline RTT.
9. Save Results At the conclusion of the test, tap [No]. Do not save the test report yet.
Page 25 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
10. Setup Select the Setup tab, select the indicated folders. and configure your test
as follows: Folder Option Value(s) Comment
Setup,
All Steps Steps
Path MTU, RTT, Walk the
Window, TCP Throughput,
Traffic Shaping
Setup, Path
MTU
MTU Upper Limit
(Bytes)
See Work Order or enter
1500 if unknown
Maximum
Transmission Unit
Setup,
Walk the
Window
Window Size 1 (KB) 32
Window Size 2 (KB) 64
Window Size 3 (KB) 128
Window Size 4 (KB) 256
Duration 30
Setup,
Traffic
Shaping
Duration (seconds) 30
Other Traffic Shaping
fields will be
autopopulated by the
TrueSpeed application
Setup, TCP
Throughput
Window Size
Set as close as possible to
the Ideal the “Ideal TCP
Window” displayed in the
Step #4 Help box) without
exceeding it.
See highlighted field
in the screenshot
below.
File Size per
Connection (MB)
Set to value that file
transfer time value in the
Step #4 help box to be at
least 10 seconds
See highlighted field
in the screenshot
below.
Number of
Connections 1
11. Run Test Ensure that the Z-side has been setup as a TCP Server, then tap
[Run TrueSpeed Test] at the bottom of the screen. The T-BERD will
test Path MTU, RTT, Walk the Window, TCP Throughput, and Traffic
Shaping.
Page 26 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
12. Save Results At the conclusion of the test, enter Customer name, Technician Name,
Test Location, and Comments at the prompt. Select the Append option,
and tap [Yes] to save the test report to the T-BERD 6000A hard drive in
PDF format. The filename, including a time and date stamp, will be
displayed in the Progress log.
13. View Summary Select the Summary tab to view status of all tests. Verify that all tests
PASS and the displayed values meet the performance objectives of the
line under test.
14. Exit Tap [Exit] to return to the main Results view.
Page 27 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
3.2 JDSU T-BERD 6000A TCP Server setup
Use this procedure to set up a T-BERD 6000A as a TCP Server.
Step Action Details
1. Select Test For Electrical handoffs: In the Test menu at the top of the Results screen,
and select Ethernet>10/100/1000>Layer 4 TCP Wirespeed>
IPv4>Terminate.
For Optical Handoffs: In the Test menu at the top of the Results screen,
and select Ethernet>1GigE Optical>Layer 4 TCP Wirespeed>
IPv4>Terminate.
Page 28 of 28
Technical Support [email protected] 1 866 228-3762
Systems Engineer [email protected] 321-243-0600
2. Reset to Defaults In the Tools menu, select Reset Test to Defaults. Press OK to continue.
3. Setup Press the SETUP soft key on the top right side of screen.
For Electrical Handoffs: Select the indicated folders and configure your
test as follows. Folder Option Value(s) Comment
Interface,
Connector
Electrical
Connector SFP1 or SFP2
Select
ETHERNET 1000BASE-T SFP
Interface,
Physical
Layer
Auto
Negotiation See Work Order Set to same value as Ethernet switch port.
For Optical Handoffs: Select the indicated folders and configure your
test as follows. Folder Option Value(s) Comment
Interface,
Connector
Optical
Connector SFP1 or SFP2
Select desired optical SFP (1000BASE-
SX, 1000BASE-LX, etc.)
Interface,
Physical
Layer
Auto
Negotiation See Work Order Set to same value as Ethernet switch port.
For all handoffs: Select the indicated folders and configure your test as
follows. Leave all other values at default, unless specified in the Work
Order. Folder Option Value(s) Comment
All Streams
Source IP
Type Static
Source IP See Work Order For Layer 2 handoffs, set to 192.168.1.3
Default
Gateway See Work Order
For Layer 2 handoffs, set to 192,168.1.1
Subnet Mask See Work Order For Layer 2 handoffs, set to
255.255.255.0
1, Ethernet
Encapsulation See Work Order None or VLAN
VLAN ID See Work Order Options displayed after tapping VLAN
field if Encapsulation = VLAN
1, IP Destination IP See Work Order
Options displayed after tapping
Destination IP Address field. For Layer
2 handoffs, set to 192,168.1.2
TCP Host,
Ethernet
Encapsulation See Work Order None or VLAN
VLAN ID See Work Order Options displayed after tapping VLAN
field if Encapsulation = VLAN
TCP Host,
TCP Host
Settings
TCP Host
Mode Client
4. View Results Press the RESULTS button, to display the Results screen.
5. Test Inform the A-side technician that you are ready for test.