jet-rooflight basement system type sjet-gruppe.de/db/docs/5420_1_2_4_1_englisch_web-01.pdf ·...

4
JET-Rooflight Basement System Type S with S-connection rail system ... the secure connection to the roof Brochure No. 1.2.4.1 PRODUCT OVERVIEW very good light yield and outstanding design due to optional RAL 9002 colour coating permanent secure connection of the roof sheeting to the basement with help of the, as an extra available, S-connection rail system The requirements of DIN 18234-3 (version 03 / 03) are fulfilled without additional site-work Reliable drainage of water and condensate thanks to the 8° incline of the continuous rooflight bearing available in 5 construction heights: 25 cm 40 cm 45 cm 50 cm 55 cm statical calculated Advantage of the connection rail: The assembling of the continuous roof- lights can be made independently to the connection of the roof sheeting. JET-rooflight basement system type S with S-connection rail system detail with connection rail type S beading fillers on site Continuous Rooflights with Polycarbonate Chambered Panels

Upload: vanminh

Post on 18-Sep-2018

231 views

Category:

Documents


0 download

TRANSCRIPT

JET-Rooflight Basement System Type Swith S-connection rail system

... the secure connection to the roof

Bro

ch

ure

No

. 1

.2.4

.1

P R O D U C T OV E R V I E W

very good light yield and outstanding

design due to optional RAL 9002 colour

coating

permanent secure connection of the

roof sheeting to the basement with

help of the, as an extra available,

S-connection rail system

The requirements of DIN 18234-3

(version 03 / 03) are fulfilled without

additional site-work

Reliable drainage of water and

condensate thanks to the 8° incline of

the continuous rooflight bearing

available in 5 construction heights:

25 cm

40 cm

45 cm

50 cm

55 cm

statical calculated

Flä

che

ab

schn

eid

en

Advantage of the connection rail:

The assembling of the continuous roof-

lights can be made independently to

the connection of the roof sheeting.

JET-rooflight basement system type S with S-connection rail system

detail with connection rail type S

beading fillers on site

Continuous Rooflights with Polycarbonate Chambered Panels

Industrial Construction Architecture SHEV-Technology & Customer Service

detail: S 25

op

tiona

l25

cm

roof heat insulation on site

vapour barrier on site

sheet metal flashingon site fortrapezoidal sheet metaland insulation

exchangeon site

option:connection rail type S

with sealing profile

10 cm

detail: S 40

option:non-flammable heat insulationaccording DIN 4102-1,60 mm delivery height 30 cm, for adaption of insulation thickness on site (JET or on site)

roof heat insulation on site

vapour barrier on site

25 c

m15

cm

op

tiona

l

40 c

m

10 cm

option:connection rail type S

with sealing profile

JET-rooflight basement system type S

option:non-flammableheat insulationaccording DIN 4102-1,60 mm,(JET or on site)

Lighting technology

The coating of the vertical basements in RAL 9002 significantly increases the intensity of illumination under

the rooflight compared with a galvanized vertical basement!

It is the same when you compare a vertical galvanized basement with an inclined S-basement in RAL

9002. The intensity of illumination of the coated basement is higher, even if it has a 20 cm smaller upper

clear width (see below table).

Additional advantage for you:

A smaller rooflight order width:

- lower price

- less loss of heat in winter

- less heating in summer

Sample calculation according DIN 5034, part 6 (version 06 / 95)

Dimensions of hall: 50 m x 20 m, height: 10 m, 1 continuous rooflight integrated, length: 40 m, basement

height: 50 cm, galvanized, as alternative coated in grey white. In case of inclined basement the upper

incidence of light dimension is reduced by 20 cm in the width.

detail: S 45, S 50, S 55

option:connection rail type S

with sealing profile

option:non-flammableheat insulationaccording DIN 4102-1,60 mm delivery height 30 cm, for adaption of insulation thicknesson site (JET or on site)

vapour barrier on site

roof heat insulation on sitesample: 15 cm thickness

support plate45,5 / 4,5 cm(JET or on site)

splices have to be sealed vapour proof on site

10 cm

20 /

25 /

30 c

m25

cm

45 /

50 /

55 c

m

45,5 cm

4,5

cm

The choice of the necessary basement height

takes place due to the addition of on site used

thicknesses resp. construction heights of

trapezoidal sheet

+ heat insulation

+ sealing

+ necessary free basement height.

For SHEV according DIN 18232 basement height

minimum 25 cm over the upper edge of the roof!

Average intensity of illumination Ep of the hall

clear roof opening width(lower edge basement

system)2,00 m 3,00 m 4,00 m 5,00 m Skizze

vertical basement,50 cm high,

coated in grey whiteRAL 9002, luminous

reflectance value = 67 %

125 lx 193 lx 262 lx 330 lx

vertical basement, 50 cm high,

galvanized, luminous reflectance value = 36 %

114 lx 181 lx 249 lx 317 lx

basement type S,50 cm high,

coated in grey whiteRAL 9002, luminous

reflectance value = 67 %

115 lx 183 lx 252 lx 320 lx

basement type S, 50 cm high,

galvanized, luminous reflectance value = 36 %

108 lx 176 lx 243 lx 311 lx

rooflight order width

clear roof opening width

rooflight order width

clear roof opening width

clear roof opening width – 20 cm

Symbolic presentation of non-self supporting basements

01. rooflight head piece basement

02. rooflight basement long side

03. basement corner angle

04. basement case corner

05. basement joint connector

06. cover for basement joint

07. push-pull brace

08. push-pull diagonal brace

09. bearing

10. head piece cross bracing

11. cross bracing

04

03

0110

09

0502

07

11

08

06

distance fro

m basement joint

to the next push-pull b

race

distance fro

m

head piece to

first push-pull

brace

distance fro

m

push-pull

brace to

push-pull

brace

Symbolic presentation of self supporting basements

0103

04

07

08

06

05

02

09

11

10

distance m

iddle of

girder to m

iddle

of girder

distance

head piece

to first m

iddle

of girder

01. rooflight head piece basement

02. rooflight basement long side

03. basement corner angle

04. basement case corner

05. basement joint connector

06. cover for basement joint

07. push-pull brace

08. push-pull diagonal brace

09. bearing

10. support plate

11. spacer according

statical need

VdSVdS-approved manufacturer for

smoke and heat exhaust systemsLIGHT DOMES ~ ROOFLIGHTS ~ SHEV ~ SPECIAL GLASS AND GRILLODUR® ~ SURFACE VENTILATORS

JET Tageslicht & RWA GmbH

Weidehorst 28D- 32609 Hüllhorst

Tel. +49 (0) 5744 / 503-0Fax +49 (0) 5744 / 503-40

[email protected]

Certified in com-pliance withDIN EN ISO

9001

Bro

ch

ure

No

. 1

.2.4

.1

Valid

fro

m d

ate

of p

ublic

atio

n un

til n

ew

ed

itio

n. U

pd

ate

d: A

ugus

t 201

1. N

ot r

esp

ons

ible

for p

rintin

g e

rrors

, mist

ake

s a

nd te

chn

ica

l alte

ratio

ns.

Industrial Construction Architecture SHEV-Technology & Customer Service