EVAPORATIVE AIR COOLER 1 11. 26 OWNER’S MANUAL READ AND SAVE THESE INSTRUCTIONS Read all instructions carefully before setting up and operating this unit. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty. EVAPORATIVE AIR COOLER MODEL NO.: KS2P-18C10

Upload: hanhan

Post on 18-Mar-2018

243 views

Category:

Documents


5 download

TRANSCRIPT

EVAPORATIVE AIR COOLER

1

11. 26

OWNER’S MANUAL READ AND SAVE THESE INSTRUCTIONS

Read all instructions carefully before

setting up and operating this unit.

This manual is designed to provide

you with important information

needed to setup, operate, maintain,

and troubleshoot your cooler.

Failure to follow these instructions

may damage and/or impair its

operation and void the warranty.

EVAPORATIVE AIR COOLER

MODEL NO.: KS2P-18C10

EVAPORATIVE AIR COOLER

2

11. 26

PREFACE

We really appreciate you credit and support in advance. Our evaporative air cooler will bring you

breeze health with least energy.

Adopting the most advanced evaporative cooling technology in the world and the contemporary

production management system, this installation manual is specific for KS2P-18C10 evaporative air

cooler. To ensure the optimal efficiency, we recommend you to read the manual carefully before use.

How Evaporative cooling works

Evaporation cooling is to cool and humidify air by water evaporation to absorb heat. Do you ever

wonder why you feel cooler by the ocean? It is because hot air is blown over water causing some of

the water to evaporate and absorb heat. Evaporative air cooler working this evaporation principle.

In an evaporative cooler a circulation pump keeps the cellulose filter pads fully soaked. As warm air

passes over wet filter pads water naturally evaporates into the air. The air is cooled as it gives up the

heat required to evaporate the water.

Application areas of evaporative air cooler

(1) Relative dry and hot areas

Most of the areas which need to reduce temperature and increase ventilation can use our product,

such as mall, supermarket, office, hotel, Hospital, station, gymnasium, exhibition, restaurant, dancing

room, hall, meting-room, school, factory and villa.

(2) Relative humid areas

Evaporative air cooler is also suitable for the high-temperature or peculiar smelly factories, such as

textile mill, dress mill, printing and dyeing mill, tannery, shoes mill, plastic mill, steel works, electronic

manufacture and chemical plant. You can use our cooler to full cooling. Our cooler is also suitable for

the fuggy areas such as game or disco parlor, kitchens, refectory or hotel, you can use the cooler to

cooling and vent.

EVAPORATIVE AIR COOLER

3

11. 26

Evaporative air coolers features

(1) Well designed system ensures best cooling effect;

(2) Energy efficient and environmental friendly saving more than 80% of electricity as compare with

conventional air conditioners;

(3) The patented filter pad has over 90% of soak rate;

(4) High quality sealed aluminum motor, with good sinking effect, IP44 high level protection, stable

temperature, water-proof and good appearance;

(5) The exclusive fan blades produce large airflow and create little noise;

(6) Filter pads are easy to clean and maintain;

(7) Patented open-style water diffuser ensures high efficiency and stable water supply;

(8) Multi-lever air flow regulator.

KS2P-18C10 Technical Details

Model No. KS2P-18C10

Voltage 220V

Frequency 50Hz

Speeds 16 speed

Wattage 1100W

Max airflow 18000 m3/h

Air pressure 180 Pa

Fan type axial flow

Size of machine 1050*1050*890mm

Size of air outlet 665*665mm

Size of cooling pad (625+30)x770x100 mm

Control type LCD wall controller and remote control

Water consumption 15-20 L/h

Filter material Honeycomb

Effective area 120-150 square meters

Net/Gross Weight 65kg/70kg

Noise ≤73db

EVAPORATIVE AIR COOLER

4

11. 26

Spare parts

Main components:

Motor:

high efficiency, low noise, strong power volume

Full protection against over current, over voltage and overload

Unsurpassed reliability

Control box:

Micro-computer control, easy upgrade, can design for customer special requirement

High reliability, suit for used in various industrial environments

High protective control box, networked control system

N-hour automatic cleaning and drainage functions, keep the evaporative air coolers blow fresh

and cool air

Various optional features, increase products value

Water level probe:

Water level control

Precisely and accurately checks the water level

Device to prevent damage if the circulation pump lack of water

LCD Controller and remote control:

To control power supply and components, and implement instructions from the MCU

A large LCD screen display simplifies operations

Multi function MCU control system includes a programmed on/off function

EVAPORATIVE AIR COOLER

5

11. 26

Fan blade:

Made up of 6 pieces of high-rigid and fibrous plastic

All pieces can be adjusted the prefer angle

Strong wind volume

Drain valve:

Automatic water draining every 8hours

Prevents algae growth

Maintains clean unit

Clean and dry function

Inlet valve:

New type, smart designed, permanent magnetic valve

Small buoy, unsurpassed reliability

Water pump:

Professionally manufactured, good heat-radiating performance

Permanent magnetic synchro motor inside

Powerful, durable, high lift, low noise

Exceptional reliability in extreme conditions

EVAPORATIVE AIR COOLER

6

11. 26

Check up and adjustment before operation:

1. Is the cooler installed horizontally?

2. Is drain pipe connected to the machine?

3. Is the water supply leaking?

4. Adjust water level in the sump?

5. Is the power supply connected correctly (particularly for three phase machine)?

6. Is the power line for the control panel correctly connected?

7. Is the operation current within the rated range?

8. Is there unwanted object in the vent?

9. Is the voltage correct?

10. Does cooler vibrates noticeably while operating?

11. Is there any foreign objects in the sump?

Important notes

1. The best effect is achieved when the unit is used in a well ventilated and dry place, where the unit

takes in 100% fresh air from outside and no re-circulation occurs.

2. Avoid discharging cool air into an closed space. There must be enough space for discharged air,

even use exhaust fans

3. For a place without powered exhaust, 0.8m² of exhaust area is needed for every 3600m³/h air

discharge. When using a powered exhaust, the designed exhaust volume shall not be less than

85% of air intake.

4. Keep the unit away from welding sparks or any source of fire during the installation and when the

unit is running.

5. The unit must be tested and adjusted. E.g.: adjusting water level floats before operation. Ensure

that the unit is operating within the rated electrical currency.

6. Ensure correct wiring of the power and controller. The section in the power socket shall not be

less than 1.5mm². the units shall use a dedicated power line instead of sharing a power line with

other equipments.

7. Voltage of power supply shall be within 10% vibration from the rated voltage. Lower voltage may

cause motor start failure or undue frequent starts and stops. Long-term low voltage or high

voltage will cause damage to the motor.

8. The controller and its wire shall be kept away form strong electronic and magnetic interference,

such as frequency converter, silicon speed and temperature controller, high frequency heater

circuit or high power motor. Avoid wiring the power supply lines parallel to these sources. In the

case of unavoidability, the power line must maintain a distance of more than 30cm from parallel

interference source.

Inspection and preparation before installation

(1) Check the components and documentation (e.g.: instruction, certificate and maintenance card)

against the packing list. If there in anything missing or damaged, keep it as it was and report to the

factory or local distributor.

EVAPORATIVE AIR COOLER

7

11. 26

(2)Check the power supply for correct voltage.

Ways of installation

(1) Cooler can be installed on the outer wall, with a side diffuser (an electromotive swing air diffuser

can be used to cover larger area);

(2) Cooler can be installed on the roof, with a multi-side air diffuser penetrate through the roof and into

the room;

(3) One or more coolers can be installed on the roof or outer wall, each connected to a duct to deliver

the cooled air evenly to the room or to the desired spot;

(4) A number of coolers can be installed on the roof or on the outer wall, connected to a single duct,

and with a powered blower in case of necessity.

(1) wall:

(2) diagram of bracket:

(3) diagram for duct adaptor

EVAPORATIVE AIR COOLER

8

11. 26

Notes:

As shown above the four installation holes at the bottom of the cooler are fixed on the four steel tubes

welded on the bracket to the cooler from moving out of place.

Circuit diagram of control box of KS2P-18C10

EVAPORATIVE AIR COOLER

9

11. 26

Tips for better duct work

(1).The duct uses zinc coated steel, glass steel and plastic duct also can be used.

(2).The air diffuser should be installed in the places where the temperature actual need to be cooled. It

depends on volume and velocity to select the specification of the air diffuser. The air diffuser is made of

aluminum, alloy or wood and the type can be selected according to the actual situation. We

recommend both single and double deflection grille. The average velocity in the duct is supposed to be

at 3-6m/s. The air draft can be controlled by a regulating valve.

(3).The specification of duct depends on flow velocity, the wind velocity in the main duct is kept at

6-8m/s while in the branch is 4-5m/s and 3-4m/s in the end.

(4).The duct system is required to be economical and to be kept smooth as well as quiet, which makes

the perfect air draft. To reduce flow resistance, the elbow’s radius of curvature is not less than 1.5

times the width of duct.

(5).The air duct should not be too long, the maximal length is 20m.

(6).Keep the duct in a straight line is much better. To reduce the pressure drop, some unnecessary

elbow and branch should be refrained.

(7).Try to use motor driven diffuser in the plane layout. The air duct should be designed as short as

possible in some places where air duct must be applied.

(8).According to the volume air, different specification of the duct is used in different section.

(9).The air duct and cooler should be connected with hose.

(10).If there are branches in design, a valve and verge board can be used to control the air volume

which reach the design requirement.

EVAPORATIVE AIR COOLER

10

11. 26

Operating approach of RTC LCD controller

1. TURN ON/ TURN OFF

1) Press the button of , you can turn on and turn off evaporative air cooler manually .

2) Hold button down for 5 seconds, the wall controller will get back to the ex-factory setting,

restart.

2. SETTING THE CLOCK

Set the clock on the wall controller before proceeding with any other programs. The picture of 2-1, the

current time is 12:00. The setting as follows:

1) Press the button, the hour will flash. Use to change hours.

2) Press the button again, the minute will flash. Use to change minutes.

3) Press the button one more time, time setting been finished.

Picture 2-1show the current time Picture 2-2 change hours

Picture 2-3 change minutes

EVAPORATIVE AIR COOLER

11

11. 26

3. FAN

The button is used to select VENT(fresh air been delivered into rooms, but the air doesn’t been

cooled).

Press button can turn on and turn off VENT function. To increase or decrease the fan speed

required, press the buttons.

4. COOL

COOL function will make the pump to work, take out water from tank to wet cooling pad. Cooled air will

be delivered.

Press button can turn on and turn off COOL unction.

When you press button, if the water level on tank is too low, the pump will stop running while

the water is enough. The COOL icon is flashing on screen, that means the pump stop running at the

moment.

Note: The pump protection also happens on water shortage when cool function been turned on.

Picture 4-1 turn on VENT and COOL Picture 4-2 pump stop running (low water)

5. CLEAN

Drain function makes motor run by contraries to clean cooling pad, turn on the drain valve, drain the

dirty water out.

Press button can turn on and turn off CLEAN unction.

Drain function running for 5 minutes, will stop automatically.

When draining, the water level will decline rapidly, so if the COOL function is still keep on, the pump

will pause automatically to protect pump, and running again when DRAIN stop and water filled enough.

EVAPORATIVE AIR COOLER

12

11. 26

Picture 5-1 turn on VENT, COOL and CLEAN

6. AUTO-CLEANING

When FAN and COOL functions work together for N hours(N can be set), air cooler will open the clean

function, drain out the dirty water in tank, and add clean water automatically.

The default of Auto- cleaning cycle is 08-hour.

Press button to set up Auto-cleaning cycle , press for 3 seconds, the Auto-cleaning cycle

will be 00 → 04 → 08 → 16 → 32 → 48 → 00 (in hours). If the Auto-cleaning cycle is 00H, the

Auto-cleaning function been cancelled.

When set Auto-cleaning cycle, the screen will show the cycle of Auto-cleaning(as shown in picture 6-1),

Auto-cleaning cycle is 08-hour. The time will disappear when setting finish.

Note: Auto-cleaning function turns on under FAN and COOL functions work together.

Picture 6-1 Auto-cleaning cycle is 08-hour

7. SWING

EVAPORATIVE AIR COOLER

13

11. 26

Note: if there is no electronic swing air diffuser, this function will not available.

Swing function means change wind direction circularly.

Press button can turn on and turn off SWING unction.

Picture 7-1turn on VENT, COOL, and SWING

8. TIMER

can turn on/turn off the timing function, the wall controller will work according to the last setting

before shutdown.

TIMER function can work on any working modes, the setting methods are same in any working modes,

take an example of manual mode (MANUAL).

8.1 TIMING TURN ON

The processes are as follows:

1) Press the button, the screen will show “--:--“, “ON” is flashing, means timing turn on function

doesn’t be set, like the picture of 8-1.

2) Press button, --:-- changes to 00:00, and the hour is flashing, use button to changes

hour, like the picture of 8-2.

2 Then Press button, the hour stop blinking, the minute is flashing, use button to changes

minutes, like the picture of 8-3.

3 Press button once again, finish the setting, the screen shows the current time 16:35 and “ON”,

means the timing turn on function is finished, like the picture of 8-4.

EVAPORATIVE AIR COOLER

14

11. 26

Picture 8-1timing turn on Picture 8-2 setting hours

Picture 8-3 setting minutes Picture 8-4finish the setting

8.2 TIMING TURN OFF

The processes are as follows:

1)Press the button, and the screen will show “18:40”, “ON” is flashing, means the machine will

be turned on at 18:40; see the picture of 8-5.

2) Press button, and the screen will show “--:--“, “OFF” is flashing, means timing turn off function

doesn’t be set; see the picture of 8-6.

3) Then Press button, “--:--” change to 00:00, the hour is blinking, press button to change

hours; like the picture of 8-7.

4) Press button, the hour stop blinking, the minute is flashing, press button to change minutes;

like the picture of 8-8.

4) Press button once again, finish the setting, the screen shows the current time “16:35”, “ON”

and “OFF”, means the timing turn on and turn off functions have been finished, like the picture of 8-9.

EVAPORATIVE AIR COOLER

15

11. 26

Picture 8-5 setting of timing turn on Picture 8-6 setting of timing turn off

Picture 8-7 setting hours Picture 8-8 setting minutes

Picture 8-9 finish the settings of timing turn on/off

8.3 CANCEL TIMING

The processes are as follows:

1)Press the button, the screen shows “18:40”, “ON” is flashing, time of turn on is 18:40,

see the picture of 8-5.

2) Press button, the screen shows “23:30”, “OFF” is flashing, time of turn off is 23:30; see the

picture of 8-10.

EVAPORATIVE AIR COOLER

16

11. 26

3) Then Press button, the screen shows “ON” and “OFF”, “--:--” is flashing, timing been canceled;

see the picture of 8-11.

4) Press button, timing function been canceled, the screen just shows current time 18:35, no any

timing setting.

Picture 8-10 setting of timing turn off Picture 8-11 cancel the setting

Picture 8-12 timing function been cancel

9. MODE

Note: This feature does not apply to all machines, it will be taken effect only for evaporative air coolers

with Relative Humidity and Temperature Detecting functions.

If your controller does not support the Relative Humidity and Temperature Detecting functions, will

show 00 ℃ and 00% on screen. (like the pictures 9-1 and 9-2)

EVAPORATIVE AIR COOLER

17

11. 26

Picture 9-1 Picture 9-2

does not support the temperature control does not support the humidity control

press button for 3 seconds, can switch air cooler’s working modes, that is MANUAL, AUTO℃,

AUTO%.

9.1 MANUAL MODE

With the wall controller on, press the button until MANUAL is shown on the top left corner of

screen. Current temperature and relative humidity will be shown on the screen. If FAN is selected, the

wall controller will show a constant fan speed, indicated on the bar graph on the bottom of screen.

If the water is enough in tank, press button, will turn on or turn off pump.

9.2 AUTO℃ MODE

Under the mode of AUTO℃, the wall controller will adjust fan speed and pump’s work to maintain the

preconcerted temperature.

When the mode switch to AUTO℃, the icons of AUTO℃, FAN and COOL will be shown on screen,

FAN and COOL functions will be turned on automatically, use buttons to change speed.

As shown in picture 9-3, current temperature is 27℃, the preconcerted temperature is 25℃, FAN and

COOL functions been turned on.

The default temperature on AUTO℃ mode is 25℃, if want to change, press button, the

preconcerted temperature will flash (as shown in picture 9-4), button will change the

preconcerted temperature, press button again, the setting is finished. The temperature has been

change to 23℃. (as shown in picture 9-5).

EVAPORATIVE AIR COOLER

18

11. 26

Picture 9-3 AUTO℃ mode Picture 9-4 set temperature

Picture 9-5 Finish the setting

9.3 AUTO% MODE

Under the mode of AUTO%, the wall controller will adjust fan speed and pump’s work to maintain the

relative humidity.

When the mode switch to AUTO%, the icons of AUTO%, FAN and COOL will be shown on screen,

FAN and COOL functions will be turned on automatically, use button to change speed.

(as shown in picture 9-6), the current relative humidity is 56%, preconcerted relative humidity is 60%,

FAN and COOL functions been turned on.

The default temperature on AUTO% mode is 60%, if want to change, press button, the

preconcerted temperature will flash(as shown in picture 9-7), use buttons to change,

press button again, the setting been finished. (as shown in picture 9-8). The relative humidity has

been change to 57%.

EVAPORATIVE AIR COOLER

19

11. 26

Picture 9-6 AUTO% mode Picture 9-6 set relative humidity

Picture 9-8 Finish the setting

10. PRE-COOLING MODE

If your wall controller is designed to allow for the saturation of the cooler’s cooling pads before the fan

is switched on. The default of pre-cooling mode is closed.

On the state of shutdown, press the buttons of and for 5 seconds, can turn on and turn

off the cooling mode. (picture 10-1 and 10-2). If the cooling mode been enabled, press the button,

the cooler will operate as follows:

(1) If the water level is low, the tank will be filled automatically. FAN icon flashes on screen. (like the

picture of 10-3).

(2) 2 minutes later, the pump will be turned on and saturate for filter pads. if the water tank still in low

water level, the pro-cooling action will be closed, and start to vent.

(3) 1 minute later, the pump stops, and fan starts running, the FAN icon shows on the screen.

Note 1: PRE-COOLING mode will not be activated if FAN been chose again shortly after turned off.

Note 2: The settings on PRE-COOLING mode will be stored automatically and continue to use in next

reboot.

EVAPORATIVE AIR COOLER

20

11. 26

Picture 10-1 Turn on PRE-COOLING mode Picture 10-2 Turn off PRE-COOLING mode

Picute10-3 PRE-COOLING function is running

11. INTELLIGENT CLEANING MODE

Note: This feature does not apply to all machines, it will be taken effect only for evaporative air coolers

with EXHAUST function. We suggest you consult to sellers before you operate this setting.

If your wall controller is designed to intelligent cleaning mode, when clean the air cooler, the motor will

run by contraries, and cooling pad been soaked. The default of intelligent cleaning mode is closed.

On the state of shutdown, press the button of and for 5 seconds, can turn on and turn

off the intelligent cleaning mode.

If intelligent cleaning mode is enabled, press the button, the cooler will operate as follows:

(1) The motor will run by contraries and exhaust air.

If the current air cooler is venting, the venting function will be stopped. 25 seconds later, exhaust

function be opened automatically. If the COOL function is working at this moment, the drain valve will

be turned on automatically, or else, no action on drain valve.

(2) 5 minutes later, the drain valve will self-closing (if been opened), air cooler resumes to the state

before cleaning.

Note: The settings on Intelligent cleaning mode will be stored automatically and continue to use in next

EVAPORATIVE AIR COOLER

21

11. 26

reboot.

Picture 11-1 Turn on INTELLIGENT Picture11-2 Turn off INTELLIGENT CLEANING

CLEANING MODE MODE

12. SHUTDOWN CLEANING MODE

If your wall controller is designed to shutdown cleaning mode, the cooler will open the clean function

automatically when shutdown. The default of shutdown cleaning mode is closed.

On the state of shutdown, press the button of and for 5 seconds, can turn on and turn

off the shutdown cleaning mode.

If shutdown cleaning mode is enabled, turn the cooler off, the cooler will operate as follows:

(1) All functions will be closed except the clean function, CLEAN icon shows on wall controller.

(2) 5 minutes later, cleaning function will turn off automatically. The screen shows nothing.

Note: The settings of shutdown cleaning mode will be stored automatically and continue to use in next

reboot.

Picture 12-1 turn on the SHUTDOWN picture 12-2 turn off the SHUTDOWN CLEANING

CLEANING MODE MODE

13. SUGGESTIONS

EVAPORATIVE AIR COOLER

22

11. 26

COOL ICON FLASHING

COOL icon flashing (as shown in picture 4-2), indicates the water tank with low water level.

In order to product the pump, the pump will pause, and work again when water is enough.

FAN ICON FLASHING

When the FAN icon flashing (as shown in picture 10-3), that means, the air cooler is pre-cooling, pump

works for 1 minute, the FAN will be opened automatically. If the water level is too low, will water

automatically.

14. MALFUNCTIONS

E1

"E1" flashing indicates, (as shown in picture 14-1) the power supply to air cooler is over-current.

Please break the power off, and check the power supply.

Picture 14-1 over-current

E2

”E2” flashing indicates, the voltage supply to air cooler is over-voltage (more than 265V). Please break

the power off, and check the power supply.

E3

”E3” flashing indicates, the voltage supply to air cooler is under-voltage, (lower than 140V or phase

failure). Please break the power off, and check the power supply.

E8

"E8" flashing indicates, the wall controllers can’t receive the signal from air cooler, try to pull out the

signal line, and re-plug, pay attention to the good connection on communication interface.

E9

“E9” flashing indicates, the failure in water supply, if the water supply action can’t be finished within 15

minutes, please turn the COOL function off, and check the water supply system. Restart the COOL

function, the machine will add water again, that can solve the water failure caused by small water flow.

EVAPORATIVE AIR COOLER

23

11. 26

Maintenance

(1).It is to be noted to change the water while the cooler is in work to avoid incrustation.

(2).The filter pads should be cleaned more often to keep the cooling efficient. Do not use water above

40℃. Banister brush can be used softly to scrub away the dust on the pads.

(3)The water supply should be shut off to avoid bacteria as well as cold weather. It is also

recommended covering to protect the cooler in some dusty and snowy cities.

Cleaning:

(1).All the type of this series has the function of auto timing cleaning. (the cooler will operates auto

cleaning function after accumulative 8 hours under persistence power supply.)

(2).We recommend to clean the pad every month to keep the cooler under best condition.

to our related standard.

Water and power supply

(1).the water must be clean, tap water is often used and water source pressure should more than

1.0kgf/cm.

(2).there should be a stop valves in the hose and obligate a pine joint.

(3).keep the voltage only between 210-250V.

(4).there should be a switch to prevent creepage. It also should avoid short circuit, overload and

electric shock.

Temperature of Evaporative air Cooler

Vent℃

OUTSIDE℃

Relative humidity(%)

10 20 30 40 50 60 70 80 90

10 3.2 4.0 4.8 5.6 6.4 7.2 8.0 8.6 9.4

15 6.6 7.8 8.8 9.8 10.8 11.7 12.6 13.4 14.3

20 10.1 11.4 12.8 13.9 15.2 16.2 17.2 18.2 19.2

25 13.4 15.0 16.6 18.0 19.4 20.6 21.8 22.9 24.0

30 16.6 18.6 20.4 22.0 23.6 25.0 26.4 27.7 28.9

35 19.8 22.2 24.2 26.2 28.0 29.6 31.0 32.4 33.7

40 23.0 25.6 28.1 30.4 32.3 33.9

45 25.9 29.2 32.0 34.3

50 29 32.7 35.8

EVAPORATIVE AIR COOLER

24

11. 26

Troubleshooting

The following troubleshooting guide is intended to address the most common symptoms and is by no

means exhaustive. If symptoms persist, call a qualified serviceman. Only a certified electrician should

complete electrical work. Turn off all power to the cooler before attempting to troubleshoot any of following

symptoms.

Number Symptom Problem Cause Remedy

1

Unit fails to start

or deliver air

No electrical power to unit:

A. Fuse blown

B. Circuit breaker tripped

C. GFCI tripped

D. Cords unplugged or

Damaged

Check power:

A. Replace fuse

B. Reset breaker

C. Reset GFCI

D. Plug in cord or replace if damaged

Motor overheated Try restart after cool down

Motor frozen Replace motor

Motor able to free spin Replace capacitor

2

Unit starts but

air Delivery

inadequate

Insufficient air exhausts Open windows or doors

Insufficient water-pad not wet:

A. Cooling pads plugged

B. Dry streaks on pads

C. Large dry spots on pads

D. Pump not working

E. Loose water connections

Check water distribution system:

A. Clean or replace pads

B. Check water level

C. Make sure cooler is level

D. Clean or replace pump

E. Check for leaks and correct

3

Musty or

unpleasant odor

Stale or stagnant water in

sump

Drain, flush and clean sump

Pads mildewed or clogged Replace pads

Pads not completely wet

before cooler is turned on

Turn on pump before starting fan

4 Knocking,

shaking or

rattling sounds

Loose parts Check and tighten where needed

Blower wheel loose or rubbing Inspect and adjust, or replace

5

Water droplets

in the discharge

air stream

Too much water delivered to

the cooling pads

make sure pads are properly positioned in

the pad frames and The unit is level. If

necessary, reduce the flow of water to the

pads by tightening the screw on the hose

restrictor clamp found on the pump

discharge hose.

Outdoor humidity level is too

high or it is raining

Use cooler as a fan only (turn pump off)

or discontinue use of cooler until outdoor

humidity level drops.