JRAIA The Japan Refrigeration and Air Conditioning Industry
Association
October 3-5, 2011
Niagara-on-the-Lake
Canada
2
Contents
1. Future Industry Trend 2. Regulatory Trend 3. Energy Efficiency and Minimum Performance
Standard 4. MEPS and Labeling Requirement 5. Refrigerant Policies
♦ Conversion to HFCs ♦ Recovery ♦ Containment ♦ Alternatives
6. Certification/Verification and Testing 7. Renewable Energy Regulation
1-1 Transition of yearly shipment Residential Air Conditioner
Inverter
1. Future Industry Trend
Transition of yearly shipment Residential heatpump water heater
Transition of yearly shipment Commercial refrigeration and air conditioning equipment
Transition of yearly shipment Commercial Air Conditioner
Inverter
Transition of yearly shipment Centrifugal Chiller
8
1-2. Establishment of JRECO Name: JAPAN Refrigerants Environment Conservation Organization(JRECO) Date : October 1 2011 Task: ・Promotion of refrigerant emissions reduction in maintenance and equipment disposal ・Training and qualifying of engineers for refrigerant recovery ・Development of refrigerant recovery equipment ・Certification of refrigerant reclamation facilities ・Equipment registration system of refrigeration and air conditioning equipment
Back ground: Refrigerants Recycling Promotion and Technology Center, the predecessor of the current had been promoting refrigerant recovery and training engineers since its establishment in 1993.These days as refrigerant leaks have had a great effect on global warming, JAPAN Refrigerants Environment Conservation Organization was set up as an independent organization to enhance the activities against refrigerant leaks.
9
JRECO
Refrigerants Recycling Promotion and Technology Center
General Affairs Department
Engineering Department
Equipment registration center
Regulations related to environmental protection for HVAC&R products
. Law concerning the protection of the ozone layer through the control of specified substances and other measures (1988) . Law for recycling of specified kinds of home appliances ( Home appliance recycling law ) (1998) . Law regarding the rationalization of energy use (1999) . Law concerning the recovery and destruction of fluorocarbons (2001) . Law concerning the promotion of procurement of eco-friendly goods and services by the state and other entities ( Law on promoting green purchasing ) (2001)
2. Regulatory Trend
3-1 National policy to greenhouse gas control and energy saving
Kyoto Protocol
Ministry of Economy, Trade and Industry
Ministry of Land, Infrastructure and Transport
Ministry of Environment
Revision of Energy-Conservation Low (Top runner etc. 1999) (1) 1999 , (2) 2003, (3) 2006
(1) 1998 Green government building plan indicator (2) 2000 Green diagnosis / repair plan indicator (3) 2005 Green government building standard
(1) 1999 "The battle-against-global-warming promoting method" (2) 2001 "Green Purchasing Law"
Achievement Plan
- Efficient CO2 heat pump for hot-water supply: 2010 target number of 5,200,000 sets - Efficient air-conditioning machines for business use: 2010 target number of 12,000 sets
3. Energy Efficiency and Minimum Performance Standard
Specified Dimensions of Indoor Unit: Width=800mm Height=295mm Depth=free
3-2 APF Target of Wall Mounted Split A/Cs and Heat Pumps
APF Target
Indoor Unit
Cooling Capacity Under 3.2kW Under 4.0kW
Under Specified Dimensions
5.8 4.9 Over Specified
Dimensions 6.6 6.0
22.4% Energy Reduction is expected in 2010 from present value
Scope: Commercial Refrigerators,Refrigerator-freezers and Freezers. Refrigerant: Limited to those that include HFC-125,143a, 134a
Act on the Rational Use of energy
Classification
category type Inverter driven
compressor
Energy Efficiency Standards
1A Refrigerators
Upright ○ The prescription of Annual energy consumption by the volume and form division, and it is based on the calculation methods of METI
1B × 1C Chest ― 2A Refrigerator-
freezers Upright ―
2B Chest ― 3A
Freezers
Upright ― 3B Chest ― 4A Chest freezer ― 4B Frozen Stocker ―
Classification of Energy Efficiency Standards
14
New Nationwide Energy-saving Label
Label Example (Air-conditioner)
18
The Label is attached to the Products
by retailers
・Energy-saving Level shown by 5 Stars
・Green “e” mark means APF more than the top runner target, while Orange does not ・APF Performance Level (%) ・Annual Power Consumption(kWh/year)
・Annual Electricity Cost (Yen)
・Manufacturer and Model Name
“How high is the Performance of this Product ? “
4. MEPS and Labeling Requirement
15
Conversion rate reached 95% in 2004, and 100% in 2007.
0%
20%
40%
60%
80%
100%
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
CFC
HCFC HFC
5-1 Conversion to HFCs in new products
5. Refrigerant Policy
16
5-1 (2) Phaseout of HCFCs Consumption of R22 is far below the MP
level, and it is only 14.1% of baseline.
0
1,000
2,000
3,000
4,000
5,000
6,000
消費量(ODP㌧) 議定書基準量(ODP㌧)
14.1%
100%
65%
25%
10%
Phase out Schedule of HCFCs by Montreal Protocol (1995) and consumption amount of Japan
Phase out Schedule of HCFCs by Montreal Protocol (1995) Consumption amount of Japan
(ODP ton)
17
5-2 JRAIA Vision on Environmental Issues
Responsible Use Principles for HFCs
EQUIPMENT Energy Saving Emission control on a CO2 basis
REFRIGERANTS
Direct Emission Control
· Recovery activities
· Emission control in production
· Leakage reduction in use
ALTERNATE REFRIGERANTS
· Research and investigation
· Low GWP refrigerants
· Natural refrigerants
18
Current and future Bank Estimated Refrigerant Bank in Japan
0
50
100
150
200
250
300
350
400
450
Ban
k am
ount
(M
Met
ric-to
n C
O2
eq.) CFC HCFC HFC
19
5-3 Refrigerant Recovery
Three major legislation for “the end of life of products”. These laws require the recovery of refrigerant from the EOL products, and ban the release. 1) Home appliances
2) Commercial A/Cs and Refrigeration equipment 3) MAC
Total recovered amount exceeded 6,000 Metric-tons/year. ( approx. 11 M Metric-tons CO2 eq. )
This figure of 6,000 Metric-tons/year means 20% of total consumption of 33,000 Metric-tons/year of Japan.
20
0
1000
2000
3000
4000
5000
6000
7000 to
n
Residential
MAC
Commercial Industrial
Maintenance Service
End of Life
Recovery amount
11M Metric-tons CO2 eq.
21
1.Requirements for manufacture, installation, testing, operation, maintenance, repair, and disposal.
2.Requirement for leak check with log
record. - Leak check interval is determined
according to the system design and refrigerant charge in CO2 equivalent.
JRAIA Action for Containment (JARAC assisted)
Guideline (has been issued last September) ‐ Guideline for prevention of the refrigerant leakage from refrigerating and
air-conditioning equipment and systems
5-4 Refrigerant Containment
22
Conditions required for Alternatives
Note)LCCP(Life Cycle Climate Performance)
CO2 Emission origin from energy in product usage
Refrigerant Leaks in product usage
Refrigerant Leaks at product disposal
CO2 Emission at refrigerant destruction
CO2 Emission at refrigerant production
・Reasonable Cost ・Acceptable in Developing Countries
Economic Feasibility
・Ozone Depletion Potential =0 ・Low Global Warming Potential
Environment Performance
・Low Toxicity ・Low Risk of Flammability
Safety
・Superior for LCCP value ・Similar performance at high load cooling
Energy Efficient
Note)
5-5 Alternate refrigerants
23
Next Generation Refrigerants candidate for A/C
Property
Pressure (MPa)
VoL Cooling Capacity
COP Without P.drop
Flammable Class. Toxicity ODP
GWP (IPCC 4AR)
R22 1.73 100 100 Non flammable Low 0.05 1810
R410A 2.72 141 92 Non flammable Low 0 2090
HFC32 2.80 160 97 2L Low 0 675
HFO1234yf 1.16 57 90 2L Low 0 4
HFO-Mix ? ? ? 2L? ? 0 300~500 ?
R717 (NH3) 1.78 116 106 2L High 0 0
R290 (Propane) 1.53 83 98 3 Low 0 <3
R744 (CO2) 10.00 243 41 Non flammable Low 0 1
Nat
ural
Sy
nthe
tic
24
Combustion Test Results
Propane Ammonia R152a R32
24
R32 R22 + mineral oil R32 + ether oil
25
Requirement for Alternatives
Low-GWP refrigerants
- High flammable - Toxic
Low flammable 2L Class
Cannot be used High risk application
Maybe used Risk Assessment is necessary
CO2
Limited temperature on application
1234yf(100%) 32(100%)
Property of R32 and R1234yf blend
0
1 Baseline(410A)
-NEDO project revealed low GWP such as 150 blends have significantly lower efficiency than 410A. - Blends stay within flammability class 2L.
2
Composition
Rat
io to
R41
0A
Risk assessment for low flammable refrigerant
NEDO Project leader : professor Hihara Assistant leader : Mr.Fujimoto
Tokyo University
AIST Research institute for innovation
in sustainable chemistry
Tokyo University of Science, Suwa
AIST Research institute of science for safety and sustainability
Instruction discussion
Consignment
Reconsignment Reconsignment
Safety Review WG
Work together (committee)
28
A2L Refrigerant (R32,yf,ze) Risk Assessment NEDO Project by JRAIA, AIST, Tokyo Univ., Suwa Tokyo Sci. Univ. etc
Frequently Occurred 10-4 case/y C B3 A1 A2 A3
Often Occurred 10-5 case/y C B2 B3 A1 A2
Some times Occurred 10-6 case/y C B1 B2 B3 A1
Not Often Occurred 10-7 case/y C C B1 B2 B3
Might not Occurred 10-8 case/y C C C B1 B2
Not Occurred 10-9 case/y C C C C C
A Unacceptable B Acceptable in case of low risk C Acceptable
0 Ⅰ Ⅱ Ⅲ Ⅳ
No Injury Slight Injury
Light Injury
Serious Injury
Fatal Injury
Position of Severity will be studied by AIST and Univ.
Like
lihoo
d
Posi
tion
of L
ikel
ihoo
d w
ill b
e st
udie
d by
JR
AIA
Higher Severity
29
6. Certification and Testing
Testing Laboratory named JATL has been established for new organization as “Third-Party” in this April.
In near future, that laboratory will be certified national laboratory.
30
Certification
(1) Factory Audit
(2) Test Facility Calibration
(3) Product Registration and Certification Label
(4) Product Test at Random Sampling
31
Testing Facilities of JRAIA Testing Lab.
Room Type Capacity Testing product
RAC 1 Balanced Ambient Room
1.8 – 10 kW Residential AC
RAC 2 Tunnel Type Air-Enthalpy
1.8 – 10 kW Residential AC
PAC 1 Room Air-Enthalpy 5 – 28 kW Commercial AC
PAC 2 Room Air-Enthalpy 5.6 – 56 kW Commercial AC GHP
WH1 Room Air-Enthalpy 4.0 – 10kW Heat pump water heater
32
7. Renewable energy regulation There is no renewable energy regulation but some support program
Program Applied year
Required Condition subsidy
High Efficient Heat pump Water heater (Eco cute) Introduction Support Program
2002- 2010
Usage of CO2 refrigerant
For residential use 40000 yen For Commercial use 80000yen to 830000yen
High Efficient Air Conditioner Introduction Support Program
2004-2010
Vapor compression system high efficient commercial air conditioner out door unit or heat source unit
1/3 of difference cost with existing equipment
Advanced Load leveling Model Introduction Encouragement Program
2004-2010
Cold heat storage type Central air conditioning system at factory or plant
Within 1/3 of the project cost (Engineering, Facility, Installation)