Method Statement
Task: Keadue WWTP Fencing
Background Information Company Details:
Company Name: KMCF
Address: Dublin Road
Tel.:
Fax:
e-mail:
Site Location: Contact Name:
Address:
Contact No.:
Activity Construction of proposed slab and walls for the
purpose of Keadue WTTP storage
Safety Responsibility of safety:
It is the responsibility of the applicant/engineer to provide a safe working environment, for all people
who may work on that Keadue WWTP, under the Safety, Health, and Welfare at Work Act 1989.
Safety during construction:
Where undertaking any part of the work, it is the responsibilities of the applicant/engineer to seek
competent advice to ensure the stability of excavations, superstructure, stanchion foundations, wall
foundations and to avoid any other foreseeable risk
Personal protective equipment required:
Gloves to be worn at all times
Safety boots
Hard Hats
Overalls
Dust Masks
Eye & ear protection while using post driver
Power Lines:
Keadue WWTP building shall not be constructed under or nearer than 10m to an overhead power
supply.
If advice is required, or if power lines need to be diverted, it is the applicant’s responsibility to contact,
in writing, the local ESB supervisor before construction commences and then to follow the ESB
conditions.
Electric Fencing One or two strands of 2.5 mm high tensile wire shall be used
The top wire shall be 1.1 m above ground level, and where a second line wire is installed, this shall be at
600mm above ground level
Post Requirements Strainer posts shall be, at least, 2100 mm long and a minimum of 175 mm diameter and shall be driven
at least 900 mm into the ground
Strainers shall be provided at the beginning and end of every length of fencing, at gaps or openings, at
every change of direction where the angle is greater than 30º and to accommodate any significant
change in gradient
Method Statement
Where long runs of fencing are to be erected, the maximum distance between strainer posts shall not
exceed 150 m
In soft ground, the strainer length may have to be increased to provide the necessary stability. H-frames
or straining frames may be used in place of straining posts were ground conditions prevent strainer posts
being properly placed
Intermediate posts shall be, at least, 1800 mm long and a minimum of 100 mm diameter and shall be
driven at least 500 mm into the ground. Intermediate posts shall be spaced at no more than 12 m
intervals.
Driving of Posts The posts shall be driven using a purpose built post driver such that on completion of driving, the fence
shall remain stable and upright and within a tolerance of ± 25mm/metre length for the vertical
In order to protect the post from damage, the driving weight shall impact directly on the post top
For fencing, where rock or other obstructions are encountered the posts may be placed in augured holes
rather than driven
Electric Fence Insulators Terminal insulators shall be egg type, heavy duty
Intermediate insulators can be either light duty screw in type; heavy duty ring type; insulated nail type,
or plain staple combined with a short length of 12mm Heavy Duty Polythene Pipe
Wire Fixings Wire should be fixed with galvanised or zinc / aluminium coating staples
Staples shall be galvanised or zinc / aluminium coating, minimum 40 mm x 3.55 mm round. The
coating shall comply with I.S. EN 10244-2
To prevent splitting of the post, staples should be driven at an angle
Staples should not be driven home fully as such staples will the fence insulators
Installation of Electric Fence Box Electric fence shall be powered by mains driven electric fencer
Mains-operated electric fence units shall be installed in accordance with Section 705-555.03 of ET101
(National Rules for Electrical Installations)
Plant Required
Port driver
Tractor
Wire snips
Wire stretchers
Hand Tools
PPE
MATERIALS REQUIRED: Timber posts
Staples
Electric fence wire
Electric fence insulators
MAIN HAZARDS: Uncontrolled use plant and equipment
Lifting
Cutting wire