keeping you the perfect temperature...homes. often only installed in london penthouse apartments,...

12
LG ELECTRONICS UK LIMITED AIR CONDITIONING AND ENERGY SOLUTIONS AIR CONDITIONING FOR YOUR HOME KEEPING YOU THE PERFECT TEMPERATURE

Upload: others

Post on 17-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

LG ELECTRONICS UK LIMITEDAIR CONDITIONING AND ENERGY SOLUTIONS

AIR CONDITIONING FOR YOUR HOME

K E E P I N G Y O U T H E P E R F E C T T E M P E R A T U R E

Page 2: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

LGU

KRAC

EUv1

_10_

19

LG Electronics participates in the Eurovent Certification Programme for Variable

Refrigerant Flow (AC) ; the certified models are listed in the Eurovent Directory.

LG Electronics Air Conditioning and Energy SolutionsEmail: [email protected] Web: www.lg.com/uk/business/residential-air-conditioning

Copyright © 2019 LG Electronics. All rights reserved.

Information on the complete range of LG Air Conditioning products is available on the website.

LG Electronics UK Limited has been working closely with their suppliers to reduce their environmental impact on the world.

Products in this brochure contain Fluorinated Greenhouse Gases (R32)

linkedin.com/LGElectronicsUKBusinessSolutions

@LGUK_B2B

Page 3: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

ThinQ

LG Electronics Air Conditioning and Energy Solutions

LG is committed to providing reliable, innovative and technically advanced air conditioning systems, heat pumps, ventilation and smart controls offering users a completely energy efficient and comfortable environment.

LG’s units maximises interior aesthetics, that’s appropriate for any space, with their stylish designs, and simple yet functional comfort features.

With the LG ThinQ™ app, users can simply control their air conditioner remotely anytime from anywhere.

“ ”LG residential air conditioning features.

WI-FI & SMARTTHINQTM APP: Enjoy smartphone access to your unit anytime, anywhere

1-TOUCH CONTROL:Change airflow direction, sound level and cooling capacity with one click

PLASMASTERTM IONIZERPLUS:Filter out any bad odours and contagious airborne particles

DESIGN: Select a unit that blends in perfectly with your décor

CUSTOMISATION:Set a temperature schedule, personalised preferences and more

GO GREEN:Live eco-consciously with a solution that runs on R32 Refrigerant

Page 4: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

Suitable for your homes’ heating needs (and cooling during the summer)

What is Air Conditioning?

You may already be familiar with air conditioning as it is in our cars, places of work and shops that we visit. DId you know that it is also on the rise in our homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes across the UK, the irse of summer houses, home offices and property renovations all play a part in this rise, due to the trend of flexible working, working from home as well as the increase in hotter, drier summers.

What ever your reasons and what ever you need their will be an air conditioning system to meet your needs.

The basic principles of an air conditioning system is to provide the process of cooling down or heating up an area often refered to as ‘space heating’. This brochure will go through, the different types of air conditioning systems avilable and which one best suits your individual needs.

You do need planning permission approval for air conditioning to be installed in your home.

Hom

e he

atin

g an

d co

olin

g

Page 5: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

Types of air conditioning

Sleek, modern designs and the latest innovation is what you can expect from a brand like LG Electronics. Air conditioning systems with control to cool/heat one room or several rooms, at a touch of a button, mobile app or voice control remotley from anywhere. Designed for the way you live, systems from LG are available in a wide range of styles for you to create a space that’s cool, comfortable and stylish.

Whether you need a quite, comfortable room or simply want to heat/cool an area, LG air conditioning products set a high standard for energy efficiency, style and performance.

Which model is right for me?

When choosing an air conditioner, there are various things to take into account. For example, a small room might require a small 2.5kW model, while a large open-plan area might need a require a large 9kW model or even more. To get an accurate idea the following details need to be taken into account and LG would recommend your installer sizes the units for you.

Your installer will look at the size of the room (length, width and height), and the type of room - lounge, kitchen, bathroom or bedroom? The size and orientation of the windows, glass and doors. Does the room have large north facing windows or small window facing a courtyard? Even the regional climate plays a part, will you need more heating than cooling. How well is your home/room insulated.

All of the above factors need to be taken into account and that’s why LG recommend you always talk to your installer.

It is your responsibility as the home owner to ensure that your design and installation is undertaken by suitably qualified engineers. You can contact one of our distributors who will be able to provide you with an installer in your area. https://www.lg.com/uk/business/find-the-dealer

Page 6: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

R32 Refrigerant

Due to accelerated global warming and the destruction of the ozone layer, various international conventions and meetings have been held to enhance restrictions to the use of refrigerant or enforce the use of eco-conscious refrigerants. R32 refrigerant has a low global warming potential.

In order to reduce environmental destruction, refrigerant R32 is internationally acclaimed for being Eco-Concisous. It has the unprecedented feature as a low volume refrigerant that is as efficient as any conventional refrigerant; thus qualifying as a green refrigerant.

Air Conditioning systems operate on fluronitaed greenhouse gases.

Over-sized, under-sized and the right size unit.

LG have air conditioning systems in various capacities to ensure that you have the right size unit for your home.

Models to powerful for your room size will probably run lots of short cycles to achive the ideal temperature. That’s like tapping the accelerator of your car to maintain the ideal speed instead of applying steady pressure and this can result in the room getting too cold or hot and increase the power usage, costing more to run and more maintenance on the system. Models undersized come with their own problems. They will need to constantly run at maximum output in order to try to keep the space cool or hot, reducing the units life due to excessive wear.

It is important to get the right size unit(s) for your home. Contact one of our distributors who will be able to provide you with an installer in your area to size your system correctly. https://www.lg.com/uk/business/find-the-dealer

What is the right size unit?

Heating a home in the UK accounts for around 60% of a homes total energy usage. Using air conditioning to heat your space will reduce your energy costs and lower you CO2 emissions when compared to fossil-fuel boilers for heating, such as gas or oil.

Energy Management

To save energy consumption you need to ensure that your unit has been correctly sized. Air conditioning units under 12kW will have an energy label scaled from A+++ to D scale. You can also improve the efficiency of your home with insulation, double glazing and thermostatic control.

LG Air Conditioners have precise temperature control. Set the thermostat of your air condioning unit to a reasonable temperature so that the unit does not use more power than it needs to. LG’s Active Energy Control Function allows you to cap energy consumption to improve energy efficiency and reduce power consumption at a reduced cooling output.

Hom

e he

atin

g an

d co

olin

g

Page 7: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

Types of Air Conditioning Systems for Your Home

LG ARTCOOL Gallery Unit

The ARTCOOL Gallery unit, designed and manufactured by LG Electronics is a square wall mounted unit that connects to a single outdoor unit or as part of a multi split system. The image inside the frame can be changes to suit your interior or use as a photo frame.

Single splits

A split system air conditioner comprises of an outdoor unit and an indoor unit connected by refrigerant pipework. They are used to cool and/or heat a single room.

Multi splits

A multi split air conditioning system comprises of an outdoor unit, connected by refrigerant pipework to multiple indoor units which will cool and/or heat a number of different rooms within your home (up to 7 indoor units to one outdoor unit).

Types of indoor units

Indoor units come in many different designs and capacities to suit all requirements. Wall mount units, floor standing units, ceiling suspended and ducted (ducted units are hidden in a ceiling and only grilles are visible in the room).

Wi-fi Connectivity smartThinQ

Each individual member of your family can customise the air conditioner temperature and fan speed accordingly and then save the settings in their app to run it later. These settings can be saved for each air conditioner too. Control your air conditioners via the app on smart Internet devices - Android or iOS based smart phones.

Wi-Fi modem (PWFMDD200) is required for the ARTCOOL Gallery (and standard wall mount unit not featured in this brochure).

Unique to LG

Multiple devices

One device - multiple units

Ducted unit Ceiling suspended unit

Page 8: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

Installation

It is important to consider the installation process. An air conditioning system must be installed by a qualified engineer that holds an F-Gas certificate. It is your responsibility as the home owner to ensure the system is installed by a suitably qualifed engineer. Check the website to see if your installer holds an F-Gas certificate here: https://fgasregister.com/f-gas-certified-company-search

In order to gain LG’s extended product warranty the installtion needs to be done by an engineer who has also attended LG’s product technical training course.

Your installer will be able to advise you on the best place to install your indoor unit for maximum efficiency and best product performance.

You will require planning permission as air conditioning offers cooling as well as heating. The outdoor unit will need to be situated outside of the property with enough space around it for optimum airflow and installed either on wall brackets or a hard base. We recommend that the unit, if floor standing is mounted onto vibration feet.

Installation costs can vary due to the amount of different varibles involved.

Hom

e he

atin

g an

d co

olin

g

Page 9: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

Product Specifications - single split wall mounted systems

OUTDOOR DC09RQ.UL2 DC12RQ.UL2 DC18RQ.UL2 DC24RQ.U24 PC09SQ.UA3 PC12SQ.UA3 PC18SQ.UL2 PC24SQ.U24

Operation Range Cooling Min / Max °CDB -15 / 48 -15 / 48 -15 / 48 -15 / 48 -10 / 48 -10 / 48 -15 / 48 -15 / 48Heating Min / Max °CDB -15 / 24 -15 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24

Sound Pressure Cooling High dBA 49 49 53 53 48 48 53 53Heating High dBA 51 51 55 54 50 50 55 54

Sound Power Cooling High dBA 65 65 65 70 65 65 65 70Air Flow Rate Cooling High m3/min 35 35 35 50 27 27 35 50

PipingLength (Odu/Idu) Min / Max m 3 / 20 3 / 20 3 / 20 3 / 30 3 /15 3 /15 3 / 20 3 / 30

Elevation (Odu/Idu) Max m 10 10 10 15 7 7 10 15

RefrigerantType R32 R32 R32 R32 R32 R32 R32 R32GWP 675 675 675 675 675 675 675 675

Net Weight kg 34.1 34.1 34.4 46.0 25.1 25.1 34.4 46.0Dimension mm 770 x 545 x 288 770 x 545 x 288 770 x 545 x 288 870 x 650 x 330 717 x 483 x 230 717 x 483 x 230 770 x 545 x 288 870 x 650 x 330

S : Sleep / L : Low / M : Medium / H : High -Specification, design and feature are subject to change without prior notice.This product contains fluorinated greenhouse gases (R32) an A2L mildly flammable refrigerant.

MODEL NAME DELUXE STANDARD PLUS

INDOOR DC09RQ.NSJ DC12RQ.NSJ DC18RQ.NSK DC24RQ.NSK PC09SQ.NSJ PC12SQ.NSJ PC18SQ.NSK PC24SQ.NSK

CapacityCooling Min / Rated / Max W 890 / 2500 / 3700 890 / 3500 / 4040 900 / 5000 / 5500 900 / 6600 / 7420 890 / 2500 / 3700 890 / 3500 / 4040 900 / 5000 / 5500 900 / 6600 / 7420Capacity Heating +7°C W 890 / 3200 / 5000 890 / 4000 / 6000 900 / 5800 / 6400 900 / 7500 / 8640 890 / 3300 / 4100 890 / 4000 / 5100 900 / 5800 / 6400 900 / 7500 / 8640Capacity Heating -7°C W 3200 3500 4200 4850 2600 3000 4200 4850

Power InputCooling Rated W 572 933 1562 2164 656 1080 1562 2164P o w e r Input Heating +7°C W 711 976 1611 2238 800 1050 1611 2238

EER W/W 4.37 3.75 3.20 3.05 3.81 3.24 3.20 3.05S.E.E.R. 7.9 7.6 7.0 6.9 7.0 6.6 7.0 6.9COP W/W 4.5 4.1 3.60 3.35 4.13 3.81 3.60 3.35S.C.O.P. 4.6 4.6 4.3 4.2 4.0 4.0 4.3 4.2

Energy Label Cooling A++ A++ A++ A++ A++ A++ A++ A++Energy Label Heating A++ A++ A+ A+ A+ A+ A+ A+

Annual Energy Consumption

Cooling kWh 111 161 250 335 125 186 250 335Heating kWh 852 883 1270 1628 875 875 1270 1628

Sound Pressure

Cooling S / L / M / H dBA 19 / 27 / 37 / 42 19 / 27 / 37 / 42 31 / 34 / 39 / 44 31 / 34 / 42 / 47 19 / 27 / 35 / 41 19 / 27 / 35 / 41 31 / 34 / 39 / 44 31 / 34 / 42 / 47Heating L / M / H dBA 27 / 37 / 42 27 / 37 / 42 34 / 39 / 44 34 / 42 / 47 27 / 35 / 41 27 / 35 / 41 34 / 39 / 44 34 / 42 / 47

Sound Power Cooling H dBA 60 60 60 65 59 59 60 65

Air Flow Rate Cooling Sleep m3/min 3.5 / 5.5 / 9.0 / 11.0 3.5 / 5.5 / 9.0 / 11.0 8.0 / 10.5 / 13.0 / 14.5 8.0 / 10.5 / 13.1 / 16.1 3.0 / 4.2 / 7.5 / 10.0 3.0 / 4.2 / 7.5 / 10.0 8.0 / 10.5 / 13.0 / 14.5 8.0 / 10.5 / 13.1 / 16.1Max (Power) m3/min 13.0 13.0 15.5 20.0 12.5 12.5 15.5 20.0

Heating L / M / H m3/min 6.5 / 9.0 / 11.0 6.5 / 9.0 / 11.0 11.0 / 13.5 / 16.0 10.5 / 13.1 / 16.1 5.6 / 7.2 / 10.0 5.6 / 7.2 / 10.0 11.0 / 13.5 / 16.0 10.5 / 13.1 / 16.1

Running CurrentCooling Rated A 2.5 4.0 6.9 9.8 3.3 4.7 6.9 9.8

Current Cooling 6.0 6.0 9.0 14.0 6.0 6.0 9.0 14.0

Current Heating Rated 3.2 4.3 7.1 10.4 4.0 4.7 7.1 10.4Current Heating 7.0 7.0 9.5 14.0 7.0 7.0 9.5 14.0

Starting Current Cooling / Heating Rated A 2.5 / 3.2 4.0 / 4.3 6.9 / 7.1 9.8 / 10.4 3.3 4.0 4.7 4.7 6.9 7.1 9.8 / 10.4

Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Dimension mm 837 x 308 x 189 837 x 308 x 189 998 x 345 x 210 998 x 345 x 210 837 x 308 x 189 837 x 308 x 189 998 x 345 x 210 998 x 345 x 210Net Weight kg 9.1 9.1 11.9 11.9 8.7 8.7 11.9 11.9Fan Motor Output W 30 30 30 60 30 30 30 60

19dBA - extremely low noise feature

Page 10: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

MODEL NAME ARTCOOL GALLERY ARTCOOL MIRROR

INDOOR A09FR.NSF A12FR.NSF AC09BQ.NSJ AC12BQ.NSJ AC18BQ.NSK AC24BQ.NSK

CapacityCooling Min / Rated / Max W 1300 / 2500 / 3500 1300 / 3500 / 4000 890 / 2500 / 3700 890 / 3500 / 4040 900 / 5000 / 5500 900 / 6600 / 7420Capacity Heating +7°C W 1300 / 3000 / 4000 1300 / 3500 / 4500 890 / 3300 / 4100 890 / 4000 / 5100 900 / 5800 / 6400 900 / 7500 / 8640Capacity Heating -7°C W 3000 3200 2600 3000 4200 4850

Power InputCooling Rated W 700 1090 656 1080 1562 2164P o w e r Input Heating +7°C W 930 1090 800 1050 1611 2238

EER W/W 3.57 3.21 3.81 3.24 3.20 3.05S.E.E.R. 5.3 5.3 7.0 6.6 7.0 6.9COP W/W 3.22 3.21 4.13 3.81 3.60 3.35S.C.O.P. 3.8 3.8 4.0 4.0 4.3 4.2

Energy Label Cooling A A A++ A++ A++ A++Energy Label Heating A A A+ A+ A+ A+

Annual Energy Consumption

Cooling kWh 165 231 125 186 250 335Heating kWh 921 921 875 875 1270 1628

Sound Pressure

Cooling S / L / M / H dBA 26 / 28 / 40 / 45 26 / 28 / 40 / 45 19 / 27 / 35 / 41 19 / 27 / 35 / 41 31 / 34 / 39 / 44 31 / 34 / 42 / 47Heating L / M / H dBA 28 / 40 / 46 28 / 40 / 46 27 / 35 / 41 27 / 35 / 41 34 / 39 / 44 34 / 42 / 47

Sound Power Cooling H dBA 60 60 59 59 60 65

Air Flow Rate Cooling Sleep m3/min 3.8 / 4.4 / 5.9 / 7.7 3.8 / 4.4 / 5.9 / 7.7 3.0 / 4.2 / 7.5 / 10.0 3.0 / 4.2 / 7.5 / 10.0 8.0 / 10.5 / 13.0 / 14.5 8.0 / 10.5 / 13.1 / 16.1Max (Power) m3/min 9.5 9.5 12.5 12.5 15.5 20.0

Heating L / M / H m3/min 4.4 / 5.9 / 7.7 4.4 / 5.9 / 7.7 5.6 / 7.2 / 10.0 5.6 / 7.2 / 10.0 11.0 / 13.5 / 16.0 10.5 / 13.1 / 16.1

Running CurrentCooling Rated A 3.5 4.5 3.3 4.7 6.9 9.8

Current Cooling 6.0 6.0 6.0 6.0 9.0 14.0

Current Heating Rated 4.0 5.0 4.0 4.7 7.1 10.4Current Heating 7.0 7.0 7.0 7.0 9.5 14.0

Starting CurrentCooling / Heating

Rated A 3.5 / 4.0 4.5 / 5.0 3.3 / 4.0 4.7 / 4.7 6.9 / 7.1 9.8 / 10.4

Power Supply Ø / V / Hz 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50Dimension mm 600 x 600 x 146 600 x 600 x 146 837 x 308 x 192 837 x 308 x 192 998 x 345 x 212 998 x 345 x 212Net Weight kg 15.0 15.0 9.9 9.9 12.8 13.6Fan Motor Output W 16.7 16.7 30 30 30 60

Remote Control

Outdoor Unit

OUTDOOR A09FR.UL2 A12FR.UL2 AC09BQ.UA3 AC12BQ.UA3 AC18BQ.UL2 AC24BQ.UL2

Operation Range Cooling Min / Max °CDB -10 / 48 -10 / 48 -10 / 48 -10 / 48 -15 / 48 -15 / 48Heating Min / Max °CDB -10 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24 -10 / 24

Sound Pressure Cooling High dBA 49 49 48 48 53 53Heating High dBA 51 51 50 50 55 54

Sound Power Cooling High dBA 65 65 65 65 65 70Air Flow Rate Cooling High m3/min 35 35 27 27 35 50

PipingLength (Odu/Idu) Min / Max m 3 / 15 3 / 15 3 /15 3 /15 3 / 20 3 / 30

Elevation (Odu/Idu) Max m 10 10 7 7 10 15

RefrigerantType R32 R32 R32 R32 R32 R32GWP 675 675 675 675 675 675

Net Weight kg 34.1 34.1 25.1 25.1 34.4 46.0Dimension mm 770 x 545 x 288 770 x 545 x 288 717 x 483 x 230 717 x 483 x 230 770 x 545 x 288 870 x 650 x 330

S : Sleep / L : Low / M : Medium / H : High -Specification, design and feature are subject to change without prior notice.This product contains fluorinated greenhouse gases (R32) an A2L mildly flammable refrigerant.

Standard Plus

Gallery

Deluxe

Mirror

Hom

e he

atin

g an

d co

olin

g

Page 11: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

Indoor Units - Dimensional Drawings

ARTCOOL Gallery indoor unit

RE

SID

EN

TIA

L

H09AP.NSM / H12AP.NSM

A09FR.NSF/A12FR.NSF

Item No. Part Name Remark

1 Front Panel

2 Air Suction Grille

3 Knockout HoleFor pipe and

cable

(Unit: mm)

295

55

875 235

50

1 3

2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

AC09BQ.NSJ / AC12BQ.NSJ / AC09SQ.NSJ / AC12SQ.NSJ

AC18BQ.NSK / AC24BQ.NSK / AC18SQ.NSK

837

308

192

56

9

851

715

150

4

767

1 2

3

(Unit : mm)

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

Receiver

3 Air Filter

4 Knockout hole For pipe and

cable

918

170

998

872

345

60

60

11

2121

4

2

3

(Unit : mm)(Unit : mm)

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

Receiver

3 Air Suction Filter

4 Installation Plate

Item No. Part Name Description

1Refrigerant/Drain pipe

and cable routing holeKnock-out type

2Terminal Block for Power

supply and communication

inside of front

panel

3 Corner Cover -

4Remote Controller

Signal Receiver

for wireles

type

054 055

ARTCOOL Mirror AC09 / AC12

ARTCOOL Mirror AC18 / AC24

RE

SID

EN

TIA

L

H09AP.NSM / H12AP.NSM

A09FR.NSF/A12FR.NSF

Item No. Part Name Remark

1 Front Panel

2 Air Suction Grille

3 Knockout HoleFor pipe and

cable

(Unit: mm)

295

55

875 235

50

1 3

2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

AC09BQ.NSJ / AC12BQ.NSJ / AC09SQ.NSJ / AC12SQ.NSJ

AC18BQ.NSK / AC24BQ.NSK / AC18SQ.NSK

837

308

192

56

9

851

715

150

4

767

1 2

3

(Unit : mm)

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

Receiver

3 Air Filter

4 Knockout hole For pipe and

cable

918

170

998

872

345

60

60

11

2121

4

2

3

(Unit : mm)(Unit : mm)

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

Receiver

3 Air Suction Filter

4 Installation Plate

Item No. Part Name Description

1Refrigerant/Drain pipe

and cable routing holeKnock-out type

2Terminal Block for Power

supply and communication

inside of front

panel

3 Corner Cover -

4Remote Controller

Signal Receiver

for wireles

type

054 055

RE

SID

EN

TIA

L

H09AP.NSM / H12AP.NSM

A09FR.NSF/A12FR.NSF

Item No. Part Name Remark

1 Front Panel

2 Air Suction Grille

3 Knockout HoleFor pipe and

cable

(Unit: mm)

295

55

875 235

50

1 3

2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

AC09BQ.NSJ / AC12BQ.NSJ / AC09SQ.NSJ / AC12SQ.NSJ

AC18BQ.NSK / AC24BQ.NSK / AC18SQ.NSK

837

308

192

56

9

851

715

150

4

767

1 2

3

(Unit : mm)

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

Receiver

3 Air Filter

4 Knockout hole For pipe and

cable

918

170

998

872

345

60

60

11

2121

4

2

3

(Unit : mm)(Unit : mm)

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

Receiver

3 Air Suction Filter

4 Installation Plate

Item No. Part Name Description

1Refrigerant/Drain pipe

and cable routing holeKnock-out type

2Terminal Block for Power

supply and communication

inside of front

panel

3 Corner Cover -

4Remote Controller

Signal Receiver

for wireles

type

054 055

Page 12: KEEPING YOU THE PERFECT TEMPERATURE...homes. Often only installed in London penthouse apartments, air conditoninig is increasingly becoming a popular choice for our homes …

RE

SID

EN

TIA

LWALL MOUNTED DIMENSIONS

INDOOR UNIT

DC09RQ.NSJ / PC12SQ.NSJ / PC09SQ.NSJ / PC12SQ.NSJ / S09EQ.NSJ / S12EQ.NSJ

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

ReceiverHidden

3 Air Filter

4 Knockout hole For pipe and

cable

(Unit : mm)

1

2

4

3

189

837

51

56

308

DC18RQ.NSK / DC24RQ.NSK / PC18SQ.NSK / PC24SQ .NSK / S18EQ.NSK / S24EQ.NSK

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

ReceiverHidden

3 Air Filter

4 Knockout hole For pipe and

cable

(Unit : mm)

345

210

60

60

9981

4

3

2

056 057

Deluxe + Standard Plus 09 / 12

Deluxe + Standard Plus 18 / 24

Single split outdoor unit - 09 / 12

Single split outdoor unit - 18

Single split outdoor unit - 24

RE

SID

EN

TIA

L

AC09BQ.UA3 / AC12BQ.UA3 / AC09SQ.UA3 / AC12SQ.UA3 / DC09RQ.UA3DC12RQ.UA3 / PC09SQ.UA3 / PC12SQ.UA3 / S09EQ.UA3 / S12EQ.UA3

AC18BQ.UL2 / AC18SQ.UL2 / DC18RQ.UL2 / PC18SQ.UL2 / S18EQ.UL2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

* This product contains Fluorinated greenhouse gases (R410A).

235

1425

048

327

0

74 129

89 463

717 2305 267 65 16

Ø413 2

3

5

6

1271

21°21°

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

106

24

267

1554

5

122

304

234

770

277

Ø440

69

14

288

25°25°

558

330

353

1

6

5

2

3

(Unit: mm)

(Unit: mm)

(Unit: mm)

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

H09AP.U24 / H12AP.U24 / AC24BQ.UL2 / DC24RQ.UL2 / PC24SQ.UL2 / S24EQ.UL2

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

°25°

143 586

366

386

26

313

322870

515

7832

330

166

117 17

2

192

19

650

22

1

2

43

65

225°5°2525°

25°

058 059

RE

SID

EN

TIA

L

WALL MOUNTED DIMENSIONS

INDOOR UNIT

DC09RQ.NSJ / PC12SQ.NSJ / PC09SQ.NSJ / PC12SQ.NSJ / S09EQ.NSJ / S12EQ.NSJ

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

ReceiverHidden

3 Air Filter

4 Knockout hole For pipe and

cable

(Unit : mm)

1

2

4

3

189

837

51

56

308

DC18RQ.NSK / DC24RQ.NSK / PC18SQ.NSK / PC24SQ .NSK / S18EQ.NSK / S24EQ.NSK

Item No. Part Name Remark

1 Front Panel

2 Display & Signal

ReceiverHidden

3 Air Filter

4 Knockout hole For pipe and

cable

(Unit : mm)

345

210

60

60

9981

4

3

2

056 057

RE

SID

EN

TIA

L

AC09BQ.UA3 / AC12BQ.UA3 / AC09SQ.UA3 / AC12SQ.UA3 / DC09RQ.UA3DC12RQ.UA3 / PC09SQ.UA3 / PC12SQ.UA3 / S09EQ.UA3 / S12EQ.UA3

AC18BQ.UL2 / AC18SQ.UL2 / DC18RQ.UL2 / PC18SQ.UL2 / S18EQ.UL2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

* This product contains Fluorinated greenhouse gases (R410A).23

5

1425

048

327

0

74 129

89 463

717 2305 267 65 16

Ø413 2

3

5

6

1271

21°21°

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

106

24

267

1554

5

122

304

234

770

277

Ø440

69

14

288

25°25°

558

330

353

1

6

5

2

3

(Unit: mm)

(Unit: mm)

(Unit: mm)

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

H09AP.U24 / H12AP.U24 / AC24BQ.UL2 / DC24RQ.UL2 / PC24SQ.UL2 / S24EQ.UL2

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

°25°

143 586

366

386

26

313

322870

515

7832

330

166

117 17

2

192

19

650

22

1

2

43

65

225°5°2525°

25°

058 059

RE

SID

EN

TIA

L

AC09BQ.UA3 / AC12BQ.UA3 / AC09SQ.UA3 / AC12SQ.UA3 / DC09RQ.UA3DC12RQ.UA3 / PC09SQ.UA3 / PC12SQ.UA3 / S09EQ.UA3 / S12EQ.UA3

AC18BQ.UL2 / AC18SQ.UL2 / DC18RQ.UL2 / PC18SQ.UL2 / S18EQ.UL2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

* This product contains Fluorinated greenhouse gases (R410A).

235

1425

048

327

0

74 129

89 463

717 2305 267 65 16

Ø413 2

3

5

6

1271

21°21°

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

106

24

267

1554

5

122

304

234

770

277

Ø440

69

14

288

25°25°

558

330

353

1

6

5

2

3

(Unit: mm)

(Unit: mm)

(Unit: mm)

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

H09AP.U24 / H12AP.U24 / AC24BQ.UL2 / DC24RQ.UL2 / PC24SQ.UL2 / S24EQ.UL2

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

°25°

143 586

366

386

26

313

322870

515

7832

330

166

117 17

2

192

19

650

22

1

2

43

65

225°5°2525°

25°

058 059

RE

SID

EN

TIA

L

AC09BQ.UA3 / AC12BQ.UA3 / AC09SQ.UA3 / AC12SQ.UA3 / DC09RQ.UA3DC12RQ.UA3 / PC09SQ.UA3 / PC12SQ.UA3 / S09EQ.UA3 / S12EQ.UA3

AC18BQ.UL2 / AC18SQ.UL2 / DC18RQ.UL2 / PC18SQ.UL2 / S18EQ.UL2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

* This product contains Fluorinated greenhouse gases (R410A).

235

1425

048

327

0

74 129

89 463

717 2305 267 65 16

Ø413 2

3

5

6

1271

21°21°

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

106

24

267

1554

5

122

304

234

770

277

Ø440

69

14

288

25°25°

558

330

353

1

6

5

2

3

(Unit: mm)

(Unit: mm)

(Unit: mm)

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

H09AP.U24 / H12AP.U24 / AC24BQ.UL2 / DC24RQ.UL2 / PC24SQ.UL2 / S24EQ.UL2

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

°25°

143 586

366

386

26

313

322870

515

7832

330

166

117 17

2

192

19

650

22

1

2

43

65

225°5°2525°

25°

058 059

RE

SID

EN

TIA

L

AC09BQ.UA3 / AC12BQ.UA3 / AC09SQ.UA3 / AC12SQ.UA3 / DC09RQ.UA3DC12RQ.UA3 / PC09SQ.UA3 / PC12SQ.UA3 / S09EQ.UA3 / S12EQ.UA3

AC18BQ.UL2 / AC18SQ.UL2 / DC18RQ.UL2 / PC18SQ.UL2 / S18EQ.UL2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

* This product contains Fluorinated greenhouse gases (R410A).

235

1425

048

327

0

74 129

89 463

717 2305 267 65 16

Ø413 2

3

5

6

1271

21°21°

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

106

24

267

1554

5

122

304

234

770

277

Ø440

69

14

288

25°25°

558

330

353

1

6

5

2

3

(Unit: mm)

(Unit: mm)

(Unit: mm)

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

H09AP.U24 / H12AP.U24 / AC24BQ.UL2 / DC24RQ.UL2 / PC24SQ.UL2 / S24EQ.UL2

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

°25°

143 586

366

386

26

313

322870

515

7832

330

166

117 17

2

192

19

650

22

1

2

43

65

225°5°2525°

25°

058 059

RE

SID

EN

TIA

L

AC09BQ.UA3 / AC12BQ.UA3 / AC09SQ.UA3 / AC12SQ.UA3 / DC09RQ.UA3DC12RQ.UA3 / PC09SQ.UA3 / PC12SQ.UA3 / S09EQ.UA3 / S12EQ.UA3

AC18BQ.UL2 / AC18SQ.UL2 / DC18RQ.UL2 / PC18SQ.UL2 / S18EQ.UL2

WALL MOUNTED DIMENSIONS

INDOOR UNIT

* This product contains Fluorinated greenhouse gases (R410A).

235

1425

048

327

0

74 129

89 463

717 2305 267 65 16

Ø413 2

3

5

6

1271

21°21°

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

106

24

267

1554

5

122

304

234

770

277

Ø440

69

14

288

25°25°

558

330

353

1

6

5

2

3

(Unit: mm)

(Unit: mm)

(Unit: mm)

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

H09AP.U24 / H12AP.U24 / AC24BQ.UL2 / DC24RQ.UL2 / PC24SQ.UL2 / S24EQ.UL2

Item No. Part Name

1 Air Outlet

2 Control Box

3 Power and Communication Cable Hole

4 Service Valve Cover

5 Gas Pipe Connection

6 Liquid Pipe Connection

°25°

143 586

366

386

26

313

322870

515

7832

330

166

117 17

2

192

19

650

22

1

2

43

65

225°5°2525°

25°

058 059

Outdoor Units - Dimensional Drawings

Hom

e he

atin

g an

d co

olin

g