keyence sr650 complete
DESCRIPTION
Keyence 2d Code ReaderTRANSCRIPT
Max: 305 mm 12.01"Long-range
Ethernet-compatible EtherNet/IP+PoE
NEW
NEW
SR-652
SR-650HA/650/651
A NEW 2DCODE READERthat further expandsthe possibilities
NEW Ethernet-compatible Compact 2D Code ReaderHigh-resolution type SR-650HA
Close-range type SR-650Middle-range type SR-651
Long-range type SR-652
SR-650 Series
Create Space
MAX:305 mm 12.01”
With its compact body but ability to read from a max. distance of 305 mm 12.01", its capabilities have been
expanded to handle applications that require reading distance, including applications in which the reading
position is undetermined, applications in which the target workpiece is set manually and applications in which
there is limited installation space.
OOOOOOffffffffffeeeeeeeeeeeerrrrrrssssss aaaaa lllllloooonnnnnggggg-----rrrrrraaaaaaaannnnnnnngggggggeeeeeeeee ooooooooofffffff 33333330000000005555555 mmmmmmmmmmmm (((((((11111112222222222......0000000111111111""""""")))))))))))))) mmmmmmmmaaaaaaaaxxxxxxxx... iiiinnnnnn aaaaaa ccccccooooooooooooooommmmmmmmmmmmmmpppppppppppaaaaaaaaccccccccttt ssssssssiiiiizzzzzeeeee.
2
NEW
Ethernet compatible compact 2D code reader
SR-650HA/650/651 SR-652
Easy with Advanced Reading Capabilities
Ethernet + PoETCP/IP & EtherNet/IP
AAAAAAnnyyyoooonnnneeee ccccaaaannnn eeeaaaaassssiiiilllyyyy uuuusssseeee iiiittttssss aaaaddddvvvvaaannnnnccccceeeedddd rrrrreeeeaaaaaddddiiiinnnnggggggg cccccaaaaaapppppaaaabbbbiiilllliiitttttiiiiiiieeeeeessssss....
High-Performance with Easy Tuning
Tuning is executed automatically just by setting the code
and clicking once. Easily detects the optimal conditions,
even for reading that is high in difficulty, thus allowing
anyone to quickly introduce this device.
We have consolidated KEYENCE’s original optical
design with decoding technology. It has been equipped
with advanced reading capabilities that not only support
difficult-to–read codes but flexibly support codes whose
reading conditions change.
Click
Connect to the Network
In addition to addressing the need “to manage multiple readers in batches”, with Ethernet connection, it is
also possible to address the need “to check read images in real time”.
Also, because it is possible to supply power via PoE, there is no need to prepare a separate power source.
Easy & High-Performance
3
Reverse Ernostar lens
Examples of codes that can be read with the SR-650 Series
A reverse Ernostar lens is utilized to
minimize aberration. Although small,
the reverse Ernostar lens is practically
free from image distortion and offers
excellent reading performance. Since
it is glass, the reverse Ernostar lens
resists environmental changes and
maintains stable reading, even under
severe manufacturing conditions.
A WELL THOUGHT OUT OPTICAL DESIGNA WELL THOUGHT OUT OPTICAL DESIGNPrecisely captures codes with sufficient light intensity and a high-sensitivity sensor to
achieve accurate and high-speed decoding.
Provides a high illumination light source to improve reading capabilities on moving objects and diffcult-to-read codes.
Provides faster imaging speed and improved stability
Enables high-speed decoding
Reduces aberrations to improve image clarity and reading stability
Bleeding
Powerful against difficult-to-read codes!
HIGH-INTENSITY LED
REVERSE ERNOSTAR LENS
HIGH-SPEED,HIGH-SENSITIVITY CMOS
HIGH-SPEED DSP
Light intensity:
2.5 times greater
than conventional readers
Approx. 40x
greater code recognition
Accurately position the reader
LASER POINTER
Uses the best READING and RESPONSE capabilities “Clearly” reads difficult-to-read codes and moving objects.
Also supports and reads codes that have changed in state due to variations in the print density or material.
KEYENCE’s knowhow on decoding technology has been consolidated in its compact body.
Image clarity:
2 times greater than
conventional readers
Sensitivity:
8 times greater than
conventional readers
Imaging speed:
3 times greater
than conventional readers
Processing speed:
3 times greater
than conventional readers
Approx. 3x
greater reading speed
Primary noise Low contrast Scratched Stray dots Thick printing Thin printing
Dot printing Misaligned dotsTrapezoidaldistortion Narrow quiet zone Thin pattern
Tread barreldistortion Parallel distortion
Nylon resin Black resin Stainless steel Aluminum Brass PCB Ceramic
4
PositioningLights up the pointer
Searches reading conditionsReading test
Selects bank numberBank registration
TUNE
TUNE
Settings through the settings softwareSettings through main unit control
1
1 2 3
2
3
Set the target code to the reading area
for the reader
Automatically finds the optimal reading
conditions
Registers reading conditions to the
main unit
TUNETEST
Push!
Push!
Push!
Laser-Aim Monitor Just click
Displays on
the monitor...
Just click "Tuning"!
Multi-LED display
Displays reading stability and bank numbers
Tuning
Settings that offer ease of use through procedures that are as short as possibleAnyone can easily bring out the best reading capabilities. Compact but can be setup and tested using the switches on the
main unit. Settings are completed in the shortest possible procedures using software control, too. It has inherited “features that
support the SR Series”.
EASY TUNING IN 3 STEPSEASY TUNING IN 3 STEPSTuning can be performed from the main unit or the settings software.
You can experience the best reading capabilities with easy procedures.
Even from the settings softwareEven from the main unit
TUNE switch/TEST switch
Activates tuning mode or test mode
POSITIONING
BANK REGISTRATION
TUNING
5
NEW
SR-650 Series Settings Software
AutoID Network Navigator SR-H65W
The four models of the SR-650 Series cover a wide range of applications from reading tiny codes printed on very small parts to reading
codes from long distance. In addition, KEYENCE’s Parameter Bank function enables stable reading even if the size or shape of the
parts change.
Featuring a four model lineup to accommodate various applications
EXPANDING APPLICATION POSSIBILITIES
Checks through software
Read image data
Can supply power via PoE
Power can be supplied from the Ethernet cable, making it possible to streamline the laying of
power source cables and allowing for reduction in cost, and manhours.
PoE
PC
PCPLC
SR-650 Series
FTP
In addition to data, it can also transfer captured images in real time. Can quickly check a reading status and read error images. Also,
by making it possible to construct a multi-vendor network, it easily achieves connection with other devices.
Supports Ethernet (TCP/IP and EtherNet/IP) + PoE
SUPPORTS MULTIPLE MONITORS
Can check image data captured
at the manufacturing site in real
time (up to 16). Can instantly
judge a reading status during
operation.
POWER
SUPPLY
6
High-resolution
SR-650HA
Close-range
SR-650
Middle-range
SR-651
Long-range
SR-652
Minimum resolution 0.082 mm 3.23 Mil 0.127 mm 5 Mil 0.25 mm 9.84 Mil 0.19 mm 7.48 Mil
Focal distance 38 mm 1.50" 60 mm 2.36" 100 mm 3.94" 250 mm 9.84"
0
50 1.97"
100 3.94"
150 5.91"
200 7.87"
250 9.84"
300 11.81"
* The reading range is a value measured with a KEYENCE test label. Max 305 mm 12.01" is for DataMatrix (cell size 0.5 mm 0.02")
Reading distance(mm inch)
Max
305 mm (12.01")
Minimum resolution
0.082 mm
(3.23 Mil)
SIMPLE CONFIGURATIONS & SETUP
Connected Device Settings
Can check the No. of banks that have been read.
Arranges frequently used command buttons.Parameter bank function See P. 8
Exposure time calculation for reading moving objects
Reading field of view simulation
Can create condition settings for each code type
Can check real-time images while executing test mode.
It is possible to find the best model and execute a simulation of the field of view when using that model just by entering the code size
and operating distance.
Easy-review introduction guide for installation conditions, etc.
TUNING TESTING & SETUP NETWORK SETTINGS BASIC SETTINGS
Reading test can be easily executed. Can check read ratio, cycle time, and banks that are used for reading.
Reduces manhours for setup with live view
IP address settings for the connection destination and settings for transferring images when a read error occurs can both be
completed by intuitively checking and then entering the settings as numerical data.
Communication settings with a control device can be performed intuitively
7
NEW SR-650 Series Settings Software AutoID Network Navigator SR-H65W
EXCELLENT READING CAPABILITIES
The Hi-DR function suppresses luster to improve code contrast
Difficult-to-read workpiece due to
low contrast caused by high luster
Difficult-to-read workpiece due to dark
background (black resin)
Expands the printed portion of the code to
make it more uniform for simple decoding.
Shrinks the printed portion of the code,
making thick printed codes easier to read.
Combining both the expansion and
shrink filters enables printed dots to be
connected without changing the print
thickness.
Expansion Filter
CAUSES OF
READING
DIFFICULTY
Supports reading even in changing conditions
In some cases, codes with
varying marking conditions
are read, such as when
different workpieces run
along the same line.
Dot direct parts marking
requires reading that has
been processed by filtering
because there are spaces
between each cell.
With material such as resin,
coloration variation will occur
once direct parts marking has
been performed, resulting in
the lowering contrast.
Even codes that have been
marked under the same conditions
will have brightness conditions that
vary in the corners of the field of
view, making reading unstable.
Ordinary Marking Dot Marking Contrast low Misalignment
REGISTER REGISTER REGISTER REGISTER REGISTER
BANK 1BANK 1
BANK 2BANK 2
BANK 3BANK 3
BANK 4BANK 4
BANK 16BANK 16
NK 1
B
Automatically alternates 16 banks. Reads using the best conditions
The easiest way to improve code reading capability is to improve
code clarity. The SR-650 combines the proper balance of lighting and
processing to improve code clarity on all surface types.
“New” Optical Design makes Codes Brighter & Clearer
Illuminates codes withsufficient light intensity
After being clearly recognized, the code is decoded through KEYENCE’s original image filters. This provides stable reading by
reducing poor printing and noise factors.
Built-in Image Filters Provide-Stable Reading
Even if difficult-to-read codes are mixed in with ordinary codes, by registering previously read conditions to the parameter bank, it
automatically alternates between registered banks and performs reading using conditions that match the code.
Parameter Bank & Alternate Function
Shrink Filter Close Processing
Black/White Inversion
8
Displays the reading success rate.
Displays the time required for reading using a level display.
Displays the displacement from the center of the code reading area using a level display.
Reading rate measurement mode
Tact measurement mode
Code position measurement mode
TEST button
A AB C D
Read data output
Continuous imaging Decode
A B
Continuous imaging
C D
B C D
EASY TO USE ADVANCED FEATURES
An ultrahigh-intensity LED was adopted to illuminate codes that move at high
speeds. This displays the code clearly to enable high-speed, high-sensitivity
imaging. Furthermore, the built-in high-speed digital signal processing (DSP) has
greatly increased the speed of decoding as well.
* Using a test code containing the data: KEYENCE read by the SR-651
Speedy image capture performance <Max.160 m 524.93'/min*>
Burst Read mode acquires up to 8 consecutive images as
a part quickly passes through the SR-650’s field of view.
The decoding process is not performed until all images
have been captured. Conventional readers decode each
image after it is captured, preventing additional imaging
until the decode process is complete. The Burst Read mode
allows for higher speed code detection as decoding is not
performed until multiple images have been captured.
Built-in Burst Read Mode
Pressing the TEST button enables
you to start various test modes.
On-Board Test Mode
The reading area can be split into smaller focus
areas to read multiple codes in the field of view.
Data can be output in any order.
Reading Area Limitation Function
Output of data from each area in specified orderArea limitation 1
Read data 1
Read data 2
Read data 3
Area limitation 2
Area limitation 3
Power can be supplied through a direct 24 VDC power source.
Making it possible to plug in a direct power source from the
device or line equipment, allows for significant reductions in cost
and manhours that until now had to be spent for setup.
24 VDC Power Supply
The main body has been designed from environmentally
resistant magnesium die-cast, which meets IP65 specifications
for use, even in harsh environments.
Environmentally-Resistant [IP65]
9
High-resolution type
SR-650HA
SR-650: Close-range type
SR-652: Long-range typeSR-651: Middle-range type
SR-650HA: High-resolution type
MAIN UNIT
CABLE CONFIGURATION SOFTWARE
Close-range type
SR-650
Control cable
2 m : OP-87224
5 m : OP-87225
10 m : OP-87226
NFPA79 compliant Control cable
2 m : OP-87353
5 m : OP-87354
10 m : OP-87355
NFPA79 compliant Ethernet cable
2 m : OP-87359
5 m : OP-87360
10 m : OP-87361
Middle-range type
SR-651
Long-range type
SR-652
AutoID Network Navigaitor
SR-H65W
Code typeCell size
Narrow bar width
A B
DataMatrixQR
0.127 50 70
0.25 40 80
Composite character(CC-A)
0.25 36 86
Code390.127 46 74
0.33 30 100
Code128 0.25 34 90
Code typeCell size
Narrow bar width
A B
DataMatrixQR
0.19 220 260
0.25 210 270
0.33 200 280
0.5 180 305
Composite character(CC-A)
0.25 200 270
Code390.17 220 260
0.5 180 330
Code128 0.25 195 275
Code typeCell size
Narrow bar width
A B
DataMatrixQR
0.25 65 130
0.5 45 165
Composite character(CC-A)
0.25 55 135
Code390.127 75 110
0.5 45 195
Code128 0.25 50 150
Code type Cell size A B
DataMatrixQR
0.0831 39
0.127 27 42
0.25 22 50
Unit: mm inch
100
50
0
B
A
Reading
distance
(mm inch)
40 30 20 10 -20 -30 -400 -10
Focaldistance60mm
200
250
300
150
0
B
A
Reading
distance
(mm inch)
40 30 20 10 -20 -30 -400 -10
Focaldistance250mm
20
40
60
0
B
A
Reading
distance
(mm inch)
20 15 10 5 -10 -15 -200 -5
Focaldistance38 mm
100
150
200
50
0
B
A
Reading
distance
(mm inch)
80 60 40 20 -40 -60 -800 -20
Focaldistance100mm
PRODUCT L INEUP
READ ING R ANGE CHAR ACTER I ST ICS [ T YP ICA L]
10
Main unit Mounting bracket
Control cable
NFPA79 compliant Ethernet cable
SR-650/651/650HA SR-652
With port cover With cable
(79)(84.4)
9.5 9.5
(114)
28
47
28
17
(110)
4-M4
(Depth 5)
(52.5)
(51)(5.5)
(2.5)
(10.5)
(7.5)
47
37.5
17.6
30.8
34.3
1.2
13.2
7.5
10° 10°
20
33
(142)(145)
65
2
Insulating
sheet
15° 15°
5.3
R32
ø5.3
46.4
65
17.6
42.1
39.1
1.2
11.1
L
180
150
120
5
5
5
45
ø6.7
ø15
(46.5)
ø15
ø6.4
L
(27.4)
(43.2)
(13.5)
M12
Model L
OP-87224 / 87353 2 m
OP-87225 / 87354 5 m
OP-87226 / 87355 10 m
Model L
OP-87359 2 m
OP-87360 5 m
OP-87361 10 m
D I M ENS IONSUnit: mm inch
11
Model SR-650HA SR-650 SR-651 SR-652
Type High resolution Close-range Mid-range Long-range
ReceiverSensor CMOS Image Sensor
Number of pixels 752×480 pixels
LightingLight source High intensity red LED 630 nm
LED class Class 1 LED Product (IEC60825-1)
Laser pointer
Light source Visible semiconductor laser, Wavelength 660 nm
Output 60μW
Pulse duration 200μs
Laser class Class 1 Laser Product (IEC60825-1, FDA(CDRH) Part 1040.10*2)
Reading
specifications
Supported symbol
2D QR, MicroQR, DataMatrix(ECC200), PDF417, MicroPDF, MaxiCode, Composite character (CC-A, CC-B, CC-C)
Barcode *1GS1Databar, CODE39, ITF, Industrial2of5, NW-7 (Codabar), CODE128, GS1-128, CODE93,
JAN/EAN/UPC, TriopticCODE39, Postal
Minimum resolution2D 0.082 mm 0.127 mm 0.25 mm 0.19 mm
Barcode — 0.127 mm 0.127 mm 0.17mm
Reading distance
(typical examples)
DataMatrix
QR
22 to 50 mm
(Cell size= 0.25 mm)
40 to 80 mm
(Cell size= 0.25 mm)
45 to 165 mm
(Cell size= 0.5 mm)
180 to 305 mm
(Cell size= 0.5 mm)
Barcode —30 to 100 mm
(Narrow bar width = 0.33 mm)
45 to 195 mm
(Narrow bar width = 0.5 mm)
180 to 330 mm
(Narrow bar width = 0.5 mm)
Focal distance 38 mm 60 mm 100 mm 250 mm
Reading view range (focal distance) 26.6 mm×17.0 mm 42.5 mm×27.1 mm 70.6 mm×45.0 mm 65.0 mm×41.5 mm
I/O specifications
Control input
Points 2
Input type Bidirectional voltage input
Maximum rating 26.4VDC
Minimum ON voltage 15VDC
Maximum OFF current 0.2 mA or less
Control output
Points 3
Output type Photo MOS relay output
Maximum rating 30VDC
Maximum load current 1 output: 50 mA or less, 3 Total output 100 mA or less
Leakage current when OFF 0.1 mA or less
Residual voltage when ON 1 V or less
EthernetCommunication standard 10BASE-T/100BASE-TX Cat.5
Supported protocol TCP/IP, EtherNet/IP, FTP, BOOTP
Serial communication
Communication standard RS-232C compliant
Transmission speed 9600, 19200, 38400, 57600, 115200 bps
Synchronization method Asynchronous
Environmental
resistance
Enclosure rating IP65
Ambient temperature 0 to 45°C
Ambient storage temperature -10 to +50°C
Relative humidity 35 to 95% RH (No condensation)
Storage ambient humidity 35 to 95% RH (No condensation)
Ambient luminance Sunlight: 10000 lux, Incandescent lamp: 6000 lux, Fluorescent lamp: 2000 lux
Operating environment No dust or corrosive gas present
Vibration 10 to 55 Hz Double amplitude 1.5 mm/55 to 500 Hz: Acceleration 5G, 3 hours each in X, Y and Z directions
RatingPower voltage*3 Control port: 24 VDC ±10% or Ethernet port: PoE TypeA/B 36 to 57 V (Cannot supply at the same time)
Current consumption Control port: 220mA or less (When 24 VDC power supply is used) Ethernet port: PoE Power Class 2*4
Weight Approx. 160 g Approx. 175 g
Model SR-H65W
Supported OS
Microsoft Windows XP (SP3 or later)
Microsoft Windows Vista Business/Ultimate SP2 or later
Microsoft Windows 7 Professional or above
• 64-bit edition supports operation on WOW64.
Running environment*RAM: System memory 1 GB or more (2 GB or more for Windows 7)
• HDD: 512 MB or more of free space
*1 Barcodes fitted into the visual field range in size can be read.
*2 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
*3 To comply with CSA No.61010-1/UL61010-1/IEC61010-1, use the following power supply.
- one that provides Class 2 output as defined in the CEC and NEC, or
- one that has been evaluated as a Limited Power Source as defined in CAN/CSA-C22.2 No.60950-1/UL60950-1/IEC60950-1.
*4 Peak operating current for PoE Power Class 2: 210mA maximum.
*.NET Framework 3.5 SP1 or above has been installed
PRODUCT L INEUP