kiln pre heater fan power calculation
DESCRIPTION
kiln Pre heater Fan Power calculationTRANSCRIPT
![Page 1: Kiln Pre Heater Fan Power Calculation](https://reader038.vdocuments.net/reader038/viewer/2022100421/55cf8fa7550346703b9e767b/html5/thumbnails/1.jpg)
Fan Power Calculator
Height above MSL : 300 Elevation Factor :
Description Preheater
Fan
Plant TPD : 7500
Am3/Hr 1000000
Nm3/Hr 434333
1.39
Mbar 54
300
Fan Efficiency % 80
40
(of the mediam handled) 1.42
0.617
Nm3/Kg Clinker
Temp. oC
Dust load gm/m3
Air Density Kg/m3
Air Density Kg/m3
![Page 2: Kiln Pre Heater Fan Power Calculation](https://reader038.vdocuments.net/reader038/viewer/2022100421/55cf8fa7550346703b9e767b/html5/thumbnails/2.jpg)
0.657
Kw - without dust 1875.00
Kw - with dust 1996.60
Margin on shaft power 5%
Min. Motor Kw 2096.43
Motor loss + Cable Losses 0.95
Power Consumption 6.73
( At Meters ) kwh/t
Air Density Kg/m3- with dust
![Page 3: Kiln Pre Heater Fan Power Calculation](https://reader038.vdocuments.net/reader038/viewer/2022100421/55cf8fa7550346703b9e767b/html5/thumbnails/3.jpg)
Fan Power Calculator
Elevation Factor : 1.036
![Page 4: Kiln Pre Heater Fan Power Calculation](https://reader038.vdocuments.net/reader038/viewer/2022100421/55cf8fa7550346703b9e767b/html5/thumbnails/4.jpg)