kimia analitik 2 pengantar spektroskopi

84
Kimia Analitik 2 PENGANTAR SPEKTROSKOPI Sonny Widiarto Jurusan Kimia FMIPA Universitas Lampung

Upload: pilar

Post on 23-Feb-2016

286 views

Category:

Documents


2 download

DESCRIPTION

Kimia Analitik 2 PENGANTAR SPEKTROSKOPI. Sonny Widiarto Jurusan Kimia FMIPA Universitas Lampung. Bahan Pelajaran / Silabus. Kolorimetri dan Spektroskopi Radiasi elektomagnetik Sifat cahaya (sebagai gelombang - partikel) Absorpsi dan emisi Aspek kuantitatif (hukum Beer) Instrumen - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Kimia Analitik 2

PENGANTAR SPEKTROSKOPI

Sonny WidiartoJurusan Kimia FMIPAUniversitas Lampung

Page 2: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Bahan Pelajaran / Silabus

• Kolorimetri dan Spektroskopi• Radiasi elektomagnetik• Sifat cahaya (sebagai gelombang - partikel)• Absorpsi dan emisi• Aspek kuantitatif (hukum Beer)• Instrumen • Spektrofotometri UV-Vis, IR dan serapan atom

(AAS)

Page 3: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Pustaka / referensi

• Harvey ch. 10• Skoog ch. 24 dan 25 (26-28)• Pecsok ch. 8, 9, 10 (11-13)

Page 4: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Kolorimetri dan Spektroskopi

Page 5: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 6: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Radiasi Elektomagnetik

• Radiasi elektomagnetik merupakan kombinasi medan listrik dan medan magnet yang berosilasi dan merambat lewat ruang dan membawa energi dari satu tempat ke tempat yang lain

Page 7: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Dualisme Gelombang-Partikel

• Cahaya adalah energi berbentuk gelombang elekromagnetik yang kasat mata dengan panjang gelombang sekitar 380–750 nm. Pada bidang fisika, cahaya adalah radiasi elektromagnetik, baik dengan panjang gelombang kasat mata maupun yang tidak. Selain itu, cahaya adalah paket partikel yang disebut foton. Kedua definisi tersebut merupakan sifat yang ditunjukkan cahaya secara bersamaan sehingga disebut "dualisme gelombang-partikel"

Page 8: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

• Electromagnetic radiation moves in waves

Sifat gelombang

Page 9: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 10: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 11: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 12: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Sifat partikel

Page 13: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 14: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 15: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Interaksi Radiasi dan Materi

Spektroskopi

Page 16: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spektrum Elektromagnetik

Page 17: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spektrum Elektromagnetik

Page 18: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 19: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Warna dan Panjang gelombangCOLOR WAVELENGTH (λ in nm)

Ultraviolet < 380

Violet 380 – 435

Blue 436 – 480

Greenish-blue 481 – 490

Bluish-green 491 – 500

Green 501 – 560

Yellowish-green 561 – 580

Yellow 581 – 595

Orange 596 – 650

Red 651 – 780

Near Infrared > 780

Visib

le L

ight

Page 20: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Colorimetry?

• The solutions of many compounds have characteristic colors.

• The intensity of such a color is proportional to the concentration of the compound.

Page 21: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spectroscopy and Spectrophotometry??

• Light can either be transmitted or absorbed by dissolved substances

• Presence & concentration of dissolved substances is analyzed by passing light through the sample

• Spectroscopes measure electromagnetic emission

• Spectrophotometers measure electromagnetic absorption

Page 22: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

22

Jenis – jenis Analytical Spectroscopy

• Absorption• Fluoresence and Phosphoresence• Emission (atomic with flames, arcs, sparks,

and palsmas)• Chemilumenesence and Biolumenesence• Reflection

Page 23: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Absorpsi Cahaya

• White light– All colors– Polychromatic light

Page 24: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

• Monochromatic light– Light of one color

Red light is absorbedby the green solution

Page 25: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

The Spectrophotometer

Page 26: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Definitions & Symbols

• Intensity (I)• Transmittance (T)

– It’s also referred to as %T or T x 100– T = I/Io

• Where Io is the intensity of the blank

Page 27: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Graphical Relationship

• % transmission and % absorption are not linearly related to concentration

• For a graph to be useful, a straight line is needed

• ABSORBANCE = log(1/T) = -log(T)

Page 28: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Hukum Absorpsi /Hukum Beer / Hukum Beer-Lambert

• The intensity of a ray of monochromatic light decreases exponentially as the concentration of the absorbing medium increases.

• More dissolved substance = more absorption and less transmittance

Page 29: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 30: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 31: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Pengukuran Transmitansi / Absorbansi

Page 32: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 33: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 34: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 35: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 36: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 37: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 38: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spektra lebih dari satu komponen

Page 39: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Contoh: Titanium dan vanadium membentuk kompleks berwarna dengan hidrogen peroksida. Dua larutan terpisah yang mengandung 5,00 mg dari kedua logam ini ditambahkan dengan asam perklorat dan hidrogen peroksida dan dilarutkan hingga 100 mL. Larutan ketiga dibuat dengan melarutkan 1,00 g suatu alloy (campuran logam) yang hanya mengandung Ti dan V saja kemudian diperlakukan sama dengan larutan standar. Absorbansi dari ketiga larutan diukur pada panjang gelombang 410 dan 460 nm. Lebar sel 1 cm, hitunglah % V dan % Ti

Larut an A410 A460

Ti 0,760 0,513V 0,185 0,250Alloy 0,715 0,657

Page 40: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Contoh: Titanium dan vanadium membentuk kompleks berwarna dengan hidrogen peroksida. Dua larutan terpisah yang mengandung 5,00 mg dari kedua logam ini ditambahkan dengan asam perklorat dan hidrogen peroksida dan dilarutkan hingga 100 mL. Larutan ketiga dibuat dengan melarutkan 1,00 g suatu alloy (campuran logam) yang hanya mengandung Ti dan V saja kemudian diperlakukan sama dengan larutan standar. Absorbansi dari ketiga larutan diukur pada panjang gelombang 410 dan 460 nm. Lebar sel 1 cm, hitunglah % V dan % Ti

Larutan A410 A460

Ti 0,760 0,513V 0,185 0,250Alloy 0,715 0,657

Page 41: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 42: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 43: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 44: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Penyimpangan Hukum Beer• Penyimpangan Riil merupakan keterbatasan

dari Hk Beer itu sendiri, dimana Hk tersebut hanya berlaku pada keadaan larutan encer <0,01M

• Penyimpangan instrumen Beer’s law strictly applies only when measurements are made with monochromatic source radiation. In practice, polychromatic sources that have a continuous distribution of wavelengths are used in conjunction with a grating or a filter to isolate a nearly symmetric band of wavelengths surrounding the wavelength to be employed

Page 45: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

• Penyimpangan kimia Polychromatic Radiation deviations from Beer’s law appear when the absorbing species undergoes association, dissociation, or reaction with the solvent to give products that absorb differently from the analyte.

• Penyimpangan kimia (Stray radiation), commonly called stray light, is defined as radiation from the instrument that is outside the nominal wavelength band chosen for the determination. This stray radiation often is the result of scattering and reflection off the surfaces of gratings, lenses or mirrors, filters, and windows

• Mismatched Cells deviation from adherence to Beer’s law is caused by mismatched cells. If the cells holding the analyte and blank solutions are not of equal path length and equivalent in optical characteristics

Page 46: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Pengukuran foton sebagai SinyalSpektroskopi hanya dimungkinkan jika interaksi foton dengan sample menghasilkan suatu perubahan (energi, kecepatan, amplitudo, frekuensi, sudut fasa, polarisasi atau arah perambatan)

Page 47: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 48: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 49: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Absorpsi

Page 50: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 51: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spektra Absorpsi

Page 52: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 53: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Absorpsi AtomJika suatu sinar radiasi ultra violet atau visible melalui suatu medium mengandung atom-atom dalam polikromatik dilewatkan bentuk gas, maka hanya sebagian kecil dari frekuensinya yang berkurang karena serapan atom-atom. Spektra yang dihasilkan merupakan sejumlah garis-garis absorpsi yang sempit

Page 54: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 55: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 56: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 57: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Absorpsi MolekulMolekul-molekul akan mengalami 3 jenis transisi jika tereksitasi dengan adanya radiasi UV, visible maupun IR. Untuk radiasi UV maupun Vis, eksitasi berlangsung pada saat suatu elektron yang berada pada orbital atom atau molekul yang lebih rendah (energinya) dipromosikan ke orbital yang lebih tinggi. Untuk itu foton harus memiliki energi hν yang persis sama dengan ΔE. Transisi ini dinamakan transisi elektronikTransisi jenis yang lain adalah transisi vibrasional dan transisi rotasionalTransisi vibrasional terjadi disebabkan karena molekul memiliki tingkat energi yang dikaitkan dengan ikatan kimia (antara atom dengan atom) yang terdapat pada molekul

Page 58: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 59: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 60: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Contoh spektra absorpsi molekul

Page 61: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Emisi

Emisi suatu foton terjadi jika suatu analit pada tingkat energi yang lebih tinggi kembali ke tingkat energi yang lebih rendah. Keadaan energi yang lebih tinggi dapat dicapai dengan beberapa cara termasuk energi termal, energi radiasi (disebut fotoluminesensi) atau melalui reaksi kimia (kemiluminesensi)

Page 62: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 63: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spektra Emisi

Page 64: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Fluoresensi/Fosforesensi

Page 65: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 66: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 67: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Komponen Dasar Instrumentasi Spektroskopi

Page 68: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 69: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Desain Instrumen SpektrofotometerBasic Design

An instrument used to make absorbance or transmittance measurements is known as a spectrophotometer

Page 70: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 71: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 72: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Sumber Radiasi EM

Page 73: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

40V Electric Arc

Electrode

Filament

D or H Gas2 2

Sealed Quartz Tube

Sumber Energi

Spectrophotometer

Light Source: provides the light to be passed through the sample- Tungsten Lamp: visible light (320-2500 nm)

- Deuterium Lamp: ultraviolet Light (160-375 nm)

In presence of arc, some of the electrical energy is absorbed by D2 (or H2) which results in the disassociation of the gas and release of light

D2 + Eelect D*2 D’ + D’’ + h n (light produced)

Excited state

Low pressure (vacuum)

Tungsten Filament

- based on black body radiation:heat solid filament to glowing, light emitted will be characteristic of temperature more than nature of solid filament

Page 74: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 75: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 76: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Wavelength Selector

Page 77: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Filter

Page 78: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI
Page 79: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spectrophotometer

1.) Basic Design Wavelength Selector (monochromator): used to select a given wavelength of light

from the light source- Prism:

- Filter:

Page 80: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Grating

Page 81: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Monokromator

Page 82: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spectrophotometer

1.) Basic Design Wavelength Selector (monochromator): used to select a given wavelength of light

from the light source- Reflection or Diffraction Grating:

Page 83: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spectrophotometer

1.) Basic Design Sample Cell: sample container of fixed length (b).

- Usually round or square cuvet- Made of material that does not absorb light in the wavelength range of

interest

1. Glass – visible region

2. Quartz – ultraviolet

3. NaCl, KBr – Infrared region

Page 84: Kimia Analitik 2 PENGANTAR SPEKTROSKOPI

Spectrophotometer

1.) Basic Design Light Detector: measures the amount of light passing through the

sample.- Usually works by converting light signal into electrical signal

Photomultiplier tube Process: a) light hits photoemissive cathode and e- is emitted. b) an emitted e- is attracted to electrode #1 (dynode 1), which is 90V more positive. Causes several more e- to be emitted. c) these e- are attracted to dynode 2, which is 90V more positive then dynode 1, emitting more e-. d) process continues until e- are collected at anode after amplification at 9 dynodes. e) overall voltage between anode and cathode is 900V. f) one photon produces 106 – 107 electrons. g) current is amplified and measured