Photo/isometric drawing provided by manufacturer Kingspan Thermataper TT47 LPC/FM Description of Product This is an assessment of Thermataper TT47 LPC/FM, a rigid tapered board insulation that is designed to be used in flat roofing applications with a fully adhered and mechanically fixed single-ply, partially bonded built up felt, mastic asphalt and cold liquid applied waterproofing. The Thermataper board is used to form a “warm” unvented roof system and can be installed over a range of common deck types. The product is manufactured in a thickness to suit the required roof falls, although this cannot be less than 25mm. It has a thermal conductivity of 0.024-0.026 W/mK and is manufactured with a blowing agent that has zero depletion potential and low global warming potential. The product also holds certification from the BBA certificate number 06/4372 and Certification from the Loss Prevention Certification Board certificate number 388 – 1b. Key Factors Assessed Mechanical Resistance & Stability Safety in case of Fire Hygiene, health and environment Safety in Use Energy Economy and heat retention Durability serviceability and identification Validity This certificate was first issued on 15 th December 2015 and is valid until 15 th December 2022 Issue Dated 2 nd January 2020 Certificate No: EWWS548D

Upload: others

Post on 16-Oct-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Kingspan Therma taper TT47 LPC/FM - LABC

Photo/isometric drawing

provided by manufacturer

Kingspan Thermataper TT47 LPC/FM

Description of Product

This is an assessment of Thermataper TT47

LPC/FM, a rigid tapered board insulation that is

designed to be used in flat roofing applications

with a fully adhered and mechanically fixed

single-ply, partially bonded built up felt, mastic

asphalt and cold liquid applied waterproofing. The Thermataper board is used to form a

“warm” unvented roof system and can be

installed over a range of common deck types.

The product is manufactured in a thickness to

suit the required roof falls, although this

cannot be less than 25mm. It has a thermal

conductivity of 0.024-0.026 W/mK and is

manufactured with a blowing agent that has

zero depletion potential and low global

warming potential. The product also holds certification from the

BBA certificate number 06/4372 and

Certification from the Loss Prevention

Certification Board certificate number 388 –

1b.

Key Factors Assessed

Mechanical Resistance & Stability

Safety in case of Fire

Hygiene, health and environment

Safety in Use

Energy Economy and heat retention

Durability serviceability and identification

Validity

This certificate was first issued on 15th December 2015 and is valid until 15th December 2022

Issue Dated 2nd January 2020

Certificate No: EWWS548D

Page 2: Kingspan Therma taper TT47 LPC/FM - LABC

The TT47 board product is registered as a “Tapered Insulation Board for Flat Roofing”. It is suitable for use in a variety of

flat roof types including Steel, Concrete or Timber.

Depending on the roofing system a fire rating designation of AA, AB and AC for various constructions incorporating timber,

metal and calcium silicate board decking and is acceptable for use less than 6 m from a relevant boundary. For other roof

constructions designers should refer to the relevant guidance in the documents and Kingspan technical.

The product has a thermal conductivity of as low as 0.024-0.026 W/mK and is manufactured with a blowing agent that has

zero depletion potential and low global warming potential.

The product performance as always is dependent on correct selection and installation for each roof type/system.

It is therefore important that each board application is installed as per the manufacturer’s requirements so as to avoid, a

reduction in thermal performance.

The boards may require additional fixings if the building is to be subjected to high wind loads, therefore consultation must

take place with Kingspan for such installations and an assessment carried out in accordance with BS6399-2: 1997 or BS/I.S.

EN 1991-1-4: 2005

The deck should be clean and dry on installation and it should have been checked to see if it is free of dust, grease or other

defects that would detrimentally affect adhesion of the board.

The boards should be laid on an appropriate supporting structure and the design of the board layout and falls of a

successful system must take several factors into account such as, the position of the roof outlets, the extent of water run–off

required, the dimensions of the roof, presence of any existing falls or steps on the roof, location and dimensions of

permanent projections (such as roof lights, vents) and perimeter restrictions. For new roofs this information can be usually

identified from an architect’s drawing, on existing a survey of the roof will be required to provide a suitable solution. To

overcome any condensation issues the boards should be installed over a separate vapour control layer unless it is over a

sealed metal deck system, this vapour control layer should consist of a 1000 gauge (250 micron) polythene sheet, with all

joints lapped and sealed with double sided tape.

For applications where the insulation boards are to be bonded to the vapour control layer the minimum vapour control

layer should consist of a coated roofing felt complying with type 3B to BS747:2000 or S1P1 to BS8747:2007 for roofing.

For Scotland purposes:

The specifications and materials referred to have been assessed in accordance with the Building (Scotland) Regulations

2004 and in accordance with the supporting guidance in the Domestic Technical Handbooks which came into force with

effect from 1 October 2015.

Page 3: Kingspan Therma taper TT47 LPC/FM - LABC

Where reference is made on a plan or specification document to any Code of Practice, British or European Standard or

manufacturer’s instruction it shall be construed as a reference to such publication in the form in which it is in force at the

date of this Registered Detail.

The materials specified shall be for purposes of this Registered Detail and should not be changed without first gaining

approval so to do from Local Authority Building Standards Scotland [LABSS]. Failure to do so will invalidate the Registered

Detail.

The Registered Detail shall be valid for a period of 12 months from the date of issue or until otherwise invalidated by

formal notice by LABSS. The Registered Detail may be re-validated after 12 months following a request and payment of an

annual renewal fee from the Registered Detail Holder.

This Registered Detail should not be regarded as a formal approval under the building warrant process prescribed by the

Building (Scotland) Act 2003 enacted from 1 May 2005

This Registered Detail shall contribute to compliance with relevant Mandatory Standards specified under the Building

(Scotland) Regulations 2004 as amended when read with the scope, conditions and regulations sections to this Registered

Detail.

For LABC Warranty purposes:

Suitable for use as a thermal insulation layer on concrete, metal or timber pitched or flat roofs, with access limited to

maintenance only.

Roofs should incorporate an effective VCL below the boards.

The current BBA Certificate 06/4372 product sheet 1 must remain valid and not withdrawn.

Page 4: Kingspan Therma taper TT47 LPC/FM - LABC

LABC consider that, Thermataper TT47 LPC/FM will meet the functional requirements of the Building

Regulations (listed below) if the criteria detailed in this certificate are met;

The Building Regulations 2010 (as amended) England & Wales

Regulation 7 Materials and workmanship

Note: The product is acceptable.

AD A1 Structure

Note: Subject to limitations detailed in the Conditions section.

AD B4 External Fire Spread

Note: The product can contribute to meeting this requirement.

AD C2 Resistance to Moisture

Note: Subject to limitations details in Conditions section.

AD L1 Conservation of fuel and power

Note: The thermal insulation performance of this system should be considered in the

context of the contribution made to the overall performance of the roof structure.

The Building Regulations 2010 (as amended) England

AD L1 Conservation of fuel and power

Note: The thermal insulation performance of this system should be considered in the

context of the contribution made to the overall performance of the roof structure.

The Building Regulations 2010 (as amended) Wales

AD L1 Conservation of fuel and power

Note: The thermal insulation performance of this system should be considered in the

context of the contribution made to the overall performance of the roof structure.

The Building (Scotland) Regulations 2004 (as amended)

Technical Handbooks Domestic and Non-Domestic

Regulation 8 Durability, workmanship and fitness of materials

0.8.5: Ways of establishing the fitness of materials

Regulation 9 Building Standards applicable to construction

Note: Construction shall be carried out so that the work complies with the applicable

requirements of schedule 5.

Page 5: Kingspan Therma taper TT47 LPC/FM - LABC

Mandatory

Standard 1.1 Structure

Note: This product is acceptable, with reference to clauses 1.1.1, 1.1.2 and 1.1.3 of the

Domestic and Non Domestic Technical Handbooks. Refer to section 7.1 of the BBA

certificate.

Mandatory

Standard 2.8 Spread from neighbouring buildings

Note: Roofs incorporating this product can meet this Standard, with reference to clause

2.8.1 of the Domestic and Non Domestic Technical Handbooks. Refer to section 8.2

of the BBA certificate.

Mandatory

Standard 3.15 Condensation

Note: The product will contribute to a roof meeting this Standard with reference to

clauses 3.15.1, 3.15.3, 3.15.4, 3.15.5 and 3.15.6 of the Domestic and Non Domestic

Technical Handbooks. Refer to section 6.1, 6.4 and 6.6 of the BBA certificate.

Mandatory

Standard 6.1(b) Carbon Dioxide Emissions

Note: The thermal insulation performance of this product should be considered in the

context of the contribution made to the overall performance of the building.

Mandatory

Standard 6.2 Building Insulation Envelope

Note: The thermal insulation performance of this product should be considered in the

context of the contribution made to the overall performance of the building.

Page 6: Kingspan Therma taper TT47 LPC/FM - LABC

LABC Warranty

LABC Warranty conditionally accepts the use of Thermataper TT47 LPC/FM when installed and used

in accordance with the Scope and Conditions of this Certificate. Visit www.labcwarranty.co.uk for

our LABC Warranty Technical Manual requirements and Warranty conditions of acceptance.

BBA Agrément Certificate No. 16/5332 Product Sheet 1 Issue Dated 30th June 2016

Loss Prevention Certification Board, Certificate No. 388 -1B

Kingspan Data Sheet Issue 6, March 2011

Page 7: Kingspan Therma taper TT47 LPC/FM - LABC

Kingspan Insulation Ltd

Pembridge

Leominster

Herefordshire

HR6 9LA