l45 m 25 oxygenfam

Upload: jesus-ocana-calderon

Post on 03-Apr-2018

224 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 L45 M 25 OxygenFam

    1/26

  • 7/28/2019 L45 M 25 OxygenFam

    2/26

    L45 Mx Equipment and FurnishingsM2

    Oxygen System

    Overview Storage and indicating components

    Crew oxygen distribution system

    Passenger oxygen distribution system

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    3/26

    L45 Mx Equipment and FurnishingsM3

    Oxygen OverviewOxygen System

    Supplies crew with

    supplemental

    oxygen

    Supplies oxygen

    during abnormal

    or emergency

    situations

    Uses high-pressure

    storage system

    Indicates quantity

    and system status

    on the EICAS

    PRESSURE GAUGE

    LOW-PRESSURERELIEF PORT

    SHUTOFFREGULATOR

    VALVE

    HIGH-PRESSURERELIEF PORT

    OXYGENCYLINDER

    SERVICINGPORT

    PRESSURE/TEMPERATURETRANSDUCER

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    4/26

    L45 Mx Equipment and FurnishingsM4

    Oxygen Overview

    OXYGEN CYLINDER

    OXYGEN CYLINDER PRESSURE/TEMPERATURE TRANSDUCER

    OXYGEN CYLINDER CHARGING VALVE

    LOW-PRESSURE RELIEF VALVE

    CREW OXYGEN MASK CONNECTION

    PASSENGER OXYGEN CONTROL VALVE

    ALTITUDE COMPENSATING REGULATOR (OPTIONAL)

    PASSENGER OXYGENBLEED FITTING

    PASSENGER OXYGEN

    MASK CONTAINER(CABIN AREA)

    OXYGEN CYLINDER SHUTOFF VALVE

    OVERBOARD DISCHARGEINDICATOR

    OXYGEN CYLINDERSHUTOFF/REGULATOR

    CREW OXYGEN MASK CONNECTION

    PASSENGER OXYGEN

    MASK CONTAINER

    (LAVATORY AREA)

    PASSENGER OUTLET(TEST CONNECTION)

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    5/26

    L45 Mx Equipment and FurnishingsM5

    Oxygen System

    Overview Storage and indicating components

    Crew oxygen distribution system

    Passenger oxygen distribution system

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    6/26

    L45 Mx Equipment and FurnishingsM6

    Components

    Storage cylinder Cylinder shutoff-regulator valve

    Pressure gauge and charging valve

    Cylinder pressure-temperature transducer Pressure switch

    Discharge indicator

    Control switch-indicators

    Indication display

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    7/26

    L45 Mx Equipment and FurnishingsM7

    ComponentsDischarge indicator

    When high-pressure relief

    disc ruptures,

    oxygen cylinder

    pressure expels

    discharge

    indicator from

    its fitting

    High-pressure

    oxygen vents

    overboard

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    8/26

    L45 Mx Equipment and FurnishingsM8

    ComponentsTwo control

    switch-indicatorsPAX OXY/AUTO

    DEPLOY

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    9/26

    L45 Mx Equipment and FurnishingsM9

    ComponentsIndication display

    DAU collectsoxygen pressure

    and temperature

    information

    EICAS displays

    information

    Message Condition

    OXY PRESS HIOxygen pressure above 2500 psi.

    Honeywell Phase II upgrade only.

    OXYGEN OFFThe system pressure upstream of the passenger

    oxygen control valve is less than 50 psi.

    OXYGEN PRESS

    The bottle pressure is not within the normal range

    (either too high or too low).

    Deleted with Honeywell Phase II upgrade.

    OXYGEN QTY LOWOxygen quantity is below 554 liters (with 22-cubic-

    foot bottle). Honeywell Phase II upgrade only.

    PAX OXY FAIL

    A failure of the passenger oxygen valve is detected.

    Passenger oxygen mask deployment may not be

    possible.

    PAX OXY DEPLOYThe passenger masks have been manually or

    automatically commanded to deploy.

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    10/26

    L45 Mx Equipment and FurnishingsM10

    ComponentsIndication display

    DAU collectsoxygen pressure

    and temperature

    information

    EICAS displays

    information

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    11/26

    L45 Mx Equipment and FurnishingsM11

    Oxygen System

    Overview Storage and indicating components

    Crew oxygen distribution system

    Passenger oxygen distribution system

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    12/26

    L45 Mx Equipment and FurnishingsM12

    Crew Oxygen Distribution System

    Pressure-demand system availablewhen oxygen shutoff valve open

    Quick-donning masks (upper

    outboard corner of crew seat backs)

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    13/26

    L45 Mx Equipment and FurnishingsM13

    ComponentsCrew masks

    EROS

    Diluter-demand

    regulator

    Microphone

    One-hand donning

    Four operatingmodes

    -Normal

    -100% oxygen

    -Emergency

    -Test

    NORMAL ANDHALF-CIRCLE

    100% ANDHALF-CIRCLE

    EMERGENCY TEST

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    14/26

    L45 Mx Equipment and FurnishingsM14

    ComponentsPuritan Bennett

    masksDiluter-demand

    regulator

    Quick donning

    Three operating

    modes

    -Normal

    -100%

    -Emergency

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    15/26

    L45 Mx Equipment and FurnishingsM15

    ComponentsFlex hoses

    Attach masksto oxygen

    distribution

    system

    Quick disconnects

    Lower cockpitsidewalls

    Allow seats to be

    removed without

    disturbing oxygen

    system (not shown)

    OXYGEN CUP STOWAGEBOX CREW OXYGEN MASK

    FLEX HOSE ASSY

    CREW SEAT

    OXYGEN OUTLET

    SUPPLY FLEXHOSE ASSY

    CREW SEATFLEX HOSE ASSY

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    16/26

    L45 Mx Equipment and FurnishingsM16

    Oxygen System

    Overview Storage and indicating

    Overview

    Components Crew oxygen distribution system

    Passenger oxygen distribution system

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    17/26

    L45 Mx Equipment and FurnishingsM17

    Passenger Oxygen DistributionSystem Overview

    Oxygen available to control

    valve when shutoff valve is

    open on oxygen cylinder

    System pressurized only

    when control valve is open

    Continuous flow, rebreather-type system

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    18/26

    L45 Mx Equipment and FurnishingsM18

    Components

    Control panel Control valve

    Dispensing units

    Masks Bleed fitting

    Passenger outlet (test connection)

    Altitude compensating regulator(optional)

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    19/26

    L45 Mx Equipment and FurnishingsM19

    ComponentsControl panel

    Passenger oxygensystem controlled

    through PAX

    OXY/AUTO switch

    indicator

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    20/26

    L45 Mx Equipment and FurnishingsM20

    ComponentsControl valve

    Two-way latchingsolenoid valve

    with integral

    pressure switch

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    21/26

    L45 Mx Equipment and FurnishingsM21

    ComponentsSix dispensing units

    Five inpassenger

    compartment

    headliner

    One in aft

    lavatory headliner

    12 masks

    Two in each

    dispensing unit

    Pulling mask

    lanyard line

    initiatesoxygen flow

    OXYGEN CYLINDER

    OXYGEN CYLINDERPRESSURE/TEMPERATURE TRANSDUCER

    OXYGEN CYLINDER CHARGING VALVE

    LOW PRESSURE RELIEF VALVE

    PASSENGER OXYGEN CONTROL VALVE

    PASSENGER OXYGEN

    MASK CONTAINER(CABIN AREA)

    OXYGEN CYLINDER SHUTOFF VALVE

    OVERBOARD DISCHARGEINDICATOR

    OXYGEN CYLINDERSHUTOFF/REGULATOR

    CREW OXYGEN MASKCONNECTION

    PASSENGER OXYGEN

    MASK CONTAINER

    (LAVATORY AREA)

    PASSENGER OUTLET(TEST CONNECTION)

    PASSENGER OXYGENBLEED FITTING

    PASSENGEROXYGEN MASK

    CONTAINER(CABIN AREA)

    PASSENGEROXYGEN

    MASK CONTAINER(LAVATORY AREA)

    M

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    22/26

    L45 Mx Equipment and FurnishingsM22

    ComponentsBleed fitting

    Prevents smallleaks fromdeploying masks

    Relieves pressureafter closingcontrol valve

    Passenger outlet(test connection)Upper rightpassenger cabin(between FS 224and 235)

    Allows periodic

    pressure testsAltitude compensatingregulator (optional)Provides regulatedoutlet pressure as afunction of cabinaltitude

    OXYGEN CYLINDER

    OXYGEN CYLINDERPRESSURE/TEMPERATURE TRANSDUCER

    OXYGEN CYLINDER CHARGING VALVE

    LOW PRESSURE RELIEF VALVE

    PASSENGER OXYGEN CONTROL VALVE

    PASSENGER OXYGEN

    MASK CONTAINER(CABIN AREA)

    OXYGEN CYLINDER SHUTOFF VALVE

    OVERBOARD DISCHARGEINDICATOR

    OXYGEN CYLINDERSHUTOFF/REGULATOR

    CREW OXYGEN MASKCONNECTION

    PASSENGER OXYGEN

    MASK CONTAINER

    (LAVATORY AREA)

    PASSENGER OUTLET(TEST CONNECTION)

    PASSENGER OXYGENBLEED FITTING

    ALTITUDE COMPENSATING

    REGULATOR (OPTIONAL)

    CREW OXYGENMASK CONNECTION

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    23/26

    L45 Mx Equipment and FurnishingsM23

    System Operation

    Automatic operationDeployed by cabin pressure

    control system (CPCS) When cabin altitude reaches 14,000 250 feet,

    CPCS signal opens cabin oxygen valve

    PAX OXY/AUTO switch in

    normal mode (off extinguished)

    CPCS in AUTO mode

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    24/26

    L45 Mx Equipment and FurnishingsM24

    System Operation

    Manual operationPAX OXY/AUTO switch in OFF position

    (OFF illuminates)

    Cabin pressure controller bypassed

    Passenger oxygen masks do not deploy

    by CPCS signal

    To operate passenger oxygen system

    depress DEPLOY switch (ON illuminates)and masks deploy

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam

    25/26

    L45 Mx Equipment and FurnishingsM25

    Questions?

    http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt
  • 7/28/2019 L45 M 25 OxygenFam