l45 m 25 oxygenfam
TRANSCRIPT
-
7/28/2019 L45 M 25 OxygenFam
1/26
-
7/28/2019 L45 M 25 OxygenFam
2/26
L45 Mx Equipment and FurnishingsM2
Oxygen System
Overview Storage and indicating components
Crew oxygen distribution system
Passenger oxygen distribution system
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
3/26
L45 Mx Equipment and FurnishingsM3
Oxygen OverviewOxygen System
Supplies crew with
supplemental
oxygen
Supplies oxygen
during abnormal
or emergency
situations
Uses high-pressure
storage system
Indicates quantity
and system status
on the EICAS
PRESSURE GAUGE
LOW-PRESSURERELIEF PORT
SHUTOFFREGULATOR
VALVE
HIGH-PRESSURERELIEF PORT
OXYGENCYLINDER
SERVICINGPORT
PRESSURE/TEMPERATURETRANSDUCER
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
4/26
L45 Mx Equipment and FurnishingsM4
Oxygen Overview
OXYGEN CYLINDER
OXYGEN CYLINDER PRESSURE/TEMPERATURE TRANSDUCER
OXYGEN CYLINDER CHARGING VALVE
LOW-PRESSURE RELIEF VALVE
CREW OXYGEN MASK CONNECTION
PASSENGER OXYGEN CONTROL VALVE
ALTITUDE COMPENSATING REGULATOR (OPTIONAL)
PASSENGER OXYGENBLEED FITTING
PASSENGER OXYGEN
MASK CONTAINER(CABIN AREA)
OXYGEN CYLINDER SHUTOFF VALVE
OVERBOARD DISCHARGEINDICATOR
OXYGEN CYLINDERSHUTOFF/REGULATOR
CREW OXYGEN MASK CONNECTION
PASSENGER OXYGEN
MASK CONTAINER
(LAVATORY AREA)
PASSENGER OUTLET(TEST CONNECTION)
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
5/26
L45 Mx Equipment and FurnishingsM5
Oxygen System
Overview Storage and indicating components
Crew oxygen distribution system
Passenger oxygen distribution system
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
6/26
L45 Mx Equipment and FurnishingsM6
Components
Storage cylinder Cylinder shutoff-regulator valve
Pressure gauge and charging valve
Cylinder pressure-temperature transducer Pressure switch
Discharge indicator
Control switch-indicators
Indication display
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
7/26
L45 Mx Equipment and FurnishingsM7
ComponentsDischarge indicator
When high-pressure relief
disc ruptures,
oxygen cylinder
pressure expels
discharge
indicator from
its fitting
High-pressure
oxygen vents
overboard
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
8/26
L45 Mx Equipment and FurnishingsM8
ComponentsTwo control
switch-indicatorsPAX OXY/AUTO
DEPLOY
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
9/26
L45 Mx Equipment and FurnishingsM9
ComponentsIndication display
DAU collectsoxygen pressure
and temperature
information
EICAS displays
information
Message Condition
OXY PRESS HIOxygen pressure above 2500 psi.
Honeywell Phase II upgrade only.
OXYGEN OFFThe system pressure upstream of the passenger
oxygen control valve is less than 50 psi.
OXYGEN PRESS
The bottle pressure is not within the normal range
(either too high or too low).
Deleted with Honeywell Phase II upgrade.
OXYGEN QTY LOWOxygen quantity is below 554 liters (with 22-cubic-
foot bottle). Honeywell Phase II upgrade only.
PAX OXY FAIL
A failure of the passenger oxygen valve is detected.
Passenger oxygen mask deployment may not be
possible.
PAX OXY DEPLOYThe passenger masks have been manually or
automatically commanded to deploy.
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
10/26
L45 Mx Equipment and FurnishingsM10
ComponentsIndication display
DAU collectsoxygen pressure
and temperature
information
EICAS displays
information
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
11/26
L45 Mx Equipment and FurnishingsM11
Oxygen System
Overview Storage and indicating components
Crew oxygen distribution system
Passenger oxygen distribution system
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
12/26
L45 Mx Equipment and FurnishingsM12
Crew Oxygen Distribution System
Pressure-demand system availablewhen oxygen shutoff valve open
Quick-donning masks (upper
outboard corner of crew seat backs)
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
13/26
L45 Mx Equipment and FurnishingsM13
ComponentsCrew masks
EROS
Diluter-demand
regulator
Microphone
One-hand donning
Four operatingmodes
-Normal
-100% oxygen
-Emergency
-Test
NORMAL ANDHALF-CIRCLE
100% ANDHALF-CIRCLE
EMERGENCY TEST
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
14/26
L45 Mx Equipment and FurnishingsM14
ComponentsPuritan Bennett
masksDiluter-demand
regulator
Quick donning
Three operating
modes
-Normal
-100%
-Emergency
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
15/26
L45 Mx Equipment and FurnishingsM15
ComponentsFlex hoses
Attach masksto oxygen
distribution
system
Quick disconnects
Lower cockpitsidewalls
Allow seats to be
removed without
disturbing oxygen
system (not shown)
OXYGEN CUP STOWAGEBOX CREW OXYGEN MASK
FLEX HOSE ASSY
CREW SEAT
OXYGEN OUTLET
SUPPLY FLEXHOSE ASSY
CREW SEATFLEX HOSE ASSY
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
16/26
L45 Mx Equipment and FurnishingsM16
Oxygen System
Overview Storage and indicating
Overview
Components Crew oxygen distribution system
Passenger oxygen distribution system
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
17/26
L45 Mx Equipment and FurnishingsM17
Passenger Oxygen DistributionSystem Overview
Oxygen available to control
valve when shutoff valve is
open on oxygen cylinder
System pressurized only
when control valve is open
Continuous flow, rebreather-type system
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
18/26
L45 Mx Equipment and FurnishingsM18
Components
Control panel Control valve
Dispensing units
Masks Bleed fitting
Passenger outlet (test connection)
Altitude compensating regulator(optional)
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
19/26
L45 Mx Equipment and FurnishingsM19
ComponentsControl panel
Passenger oxygensystem controlled
through PAX
OXY/AUTO switch
indicator
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
20/26
L45 Mx Equipment and FurnishingsM20
ComponentsControl valve
Two-way latchingsolenoid valve
with integral
pressure switch
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
21/26
L45 Mx Equipment and FurnishingsM21
ComponentsSix dispensing units
Five inpassenger
compartment
headliner
One in aft
lavatory headliner
12 masks
Two in each
dispensing unit
Pulling mask
lanyard line
initiatesoxygen flow
OXYGEN CYLINDER
OXYGEN CYLINDERPRESSURE/TEMPERATURE TRANSDUCER
OXYGEN CYLINDER CHARGING VALVE
LOW PRESSURE RELIEF VALVE
PASSENGER OXYGEN CONTROL VALVE
PASSENGER OXYGEN
MASK CONTAINER(CABIN AREA)
OXYGEN CYLINDER SHUTOFF VALVE
OVERBOARD DISCHARGEINDICATOR
OXYGEN CYLINDERSHUTOFF/REGULATOR
CREW OXYGEN MASKCONNECTION
PASSENGER OXYGEN
MASK CONTAINER
(LAVATORY AREA)
PASSENGER OUTLET(TEST CONNECTION)
PASSENGER OXYGENBLEED FITTING
PASSENGEROXYGEN MASK
CONTAINER(CABIN AREA)
PASSENGEROXYGEN
MASK CONTAINER(LAVATORY AREA)
M
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
22/26
L45 Mx Equipment and FurnishingsM22
ComponentsBleed fitting
Prevents smallleaks fromdeploying masks
Relieves pressureafter closingcontrol valve
Passenger outlet(test connection)Upper rightpassenger cabin(between FS 224and 235)
Allows periodic
pressure testsAltitude compensatingregulator (optional)Provides regulatedoutlet pressure as afunction of cabinaltitude
OXYGEN CYLINDER
OXYGEN CYLINDERPRESSURE/TEMPERATURE TRANSDUCER
OXYGEN CYLINDER CHARGING VALVE
LOW PRESSURE RELIEF VALVE
PASSENGER OXYGEN CONTROL VALVE
PASSENGER OXYGEN
MASK CONTAINER(CABIN AREA)
OXYGEN CYLINDER SHUTOFF VALVE
OVERBOARD DISCHARGEINDICATOR
OXYGEN CYLINDERSHUTOFF/REGULATOR
CREW OXYGEN MASKCONNECTION
PASSENGER OXYGEN
MASK CONTAINER
(LAVATORY AREA)
PASSENGER OUTLET(TEST CONNECTION)
PASSENGER OXYGENBLEED FITTING
ALTITUDE COMPENSATING
REGULATOR (OPTIONAL)
CREW OXYGENMASK CONNECTION
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
23/26
L45 Mx Equipment and FurnishingsM23
System Operation
Automatic operationDeployed by cabin pressure
control system (CPCS) When cabin altitude reaches 14,000 250 feet,
CPCS signal opens cabin oxygen valve
PAX OXY/AUTO switch in
normal mode (off extinguished)
CPCS in AUTO mode
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
24/26
L45 Mx Equipment and FurnishingsM24
System Operation
Manual operationPAX OXY/AUTO switch in OFF position
(OFF illuminates)
Cabin pressure controller bypassed
Passenger oxygen masks do not deploy
by CPCS signal
To operate passenger oxygen system
depress DEPLOY switch (ON illuminates)and masks deploy
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
25/26
L45 Mx Equipment and FurnishingsM25
Questions?
http://localhost/var/www/apps/conversion/tmp/scratch_6/L45_M_Menua.ppt -
7/28/2019 L45 M 25 OxygenFam
26/26