lab sheet electric machine
TRANSCRIPT
-
8/16/2019 LAB SHEET Electric Machine
1/92
Course"EEM 2 DC Machines"
Photo: Siemens AG
SH5007-1A Version 1.0
Author: M.Germeroth
Lucas-Nülle GmbH · Siemensstraße 2 · D-50170 Kerpen (Sindorf)Tel.: +49 2273 567-0
www.lucas-nuelle.de
Some animations require that a Flash player is installed. Should yoursystem not have a Flash player installed, you can download the latestversion at any time from Macromedia.
Copyright © 2005 LUCAS-NÜLLE GmbH. All rights reserved.
LUCAS-NÜLLE Lehr- und Messgeräte GmbHSiemensstraße 2 D-50170 Kerpen
-
8/16/2019 LAB SHEET Electric Machine
2/92
-
8/16/2019 LAB SHEET Electric Machine
3/92
EEM2 DC machines
Training objectives 1Equipment for 300 W Industrial Series 2
Information page "Alternative Equipment" 3Safety 5DC shunt-wound motors 7
Connection and starting 9Rotation reversal 15Speed control 19Load characteristic 27
DC shunt-wound generators, separately excited 31Voltage control (field control range) 33Voltage polarity 37Load characteristic 41
DC shunt-wound generators, self-excited 47Rotation direction and polarity 49Load characteristic 53
DC series-wound motors 57Connection and starting 59Rotation reversal 63Load characteristic 67
DC compound-wound motors 73Load characteristics for various compound ratios 75
Copyright 85
-
8/16/2019 LAB SHEET Electric Machine
4/92
EEM2 DC machines
-
8/16/2019 LAB SHEET Electric Machine
5/92
EEM2 DC machinesTraining objectives
In this course you will acquire practical knowledge regarding the topic of DCmachines.Experiment-based investigations of series-wound, shunt-wound and compound-wound machines are at the focal point of this course and explore such aspects ashow the machines function, respond and operate.
Training contents
Motors, generators Series-wound, shunt-wound and compound-wound windings Measurement of armature current, exciter current and voltage Nominal data, rating plate Speed adjustment Rotation reversal Magnetic field weakening Armature and field resistors Power measurement with and without load
Prerequisites
Fundamentals of electrical machines Fundamentals of electrical engineering How to handle measuring instruments
Welcome to the DC machines course. The team from LUCAS-NÜLLE
wishes you lots of fun and success in completing the course topics andconducting the experiments. The following pages provide you with anoverview of the course contents and the materials and equipmentrequired.
1
-
8/16/2019 LAB SHEET Electric Machine
6/92
-
8/16/2019 LAB SHEET Electric Machine
7/92
EEM2 DC machinesInformation page "Alternative Equipment"
Universal load (SO3212-6W) for DC motors(connection example: "DC shunt-wound motor")
Starter (SO3212-6B) and field regulator (SO3212-5F) for DC motors
(connection example: "DC shunt-wound motor")
3
-
8/16/2019 LAB SHEET Electric Machine
8/92
EEM2 DC machinesInformation page "Alternative Equipment"
Starter (SO3212-6M) and field regulator (SO3212-5H) for DC motors(connection example: "DC shunt-wound motor")
4
-
8/16/2019 LAB SHEET Electric Machine
9/92
EEM2 DC machinesSafety
Basic safety instructions
In all experiments using mains voltages high, life-threatening voltages arise. For thatreason use only safety measurement leads and make sure that there are no short-circuits.
It is imperative that all of the devices, which are provided with an earth or whereearthing is possible, must be earthed. This is particularly the case for the frequencyconverter being used.
Always be very careful to check the wiring of the application modules and onlyswitch on the mains voltage after a check has been completed. Whenever possibleuse a robust current monitoring instrument in the circuit.
Always use shaft-end guards and coupling guards as protection against contactwith rotating motor parts
All locally applicable stipulations and standards governing how electrical equipmentis handled must be complied with.
5
-
8/16/2019 LAB SHEET Electric Machine
10/92
EEM2 DC machinesSafety
General instructions on handling the equipment
Check that the knurled screws at the base of the motor and the couplingsleeves (power grip) on the motor shaft are all securely fastened. Use shaft and coupling guards. Any prolonged running of the machines when operating under high loads
can subject the machines to excessive heating. The extreme case of the machine being prevented from rotating entirely
may only arise briefly. All of the machines are equipped with a thermal circuit-breaker, which
triggers when the maximum permissible operating temperature isexceeded. These switching contacts are accessible on the terminalboard and must always be connected to the corresponding connection
sockets of the mains supply and control unit. All measurements have been recorded using conventional measuring
instruments (primarily class 1.5) at the standard mains voltage(230/400V +5% -10% 50Hz) using standard production machines.Experience suggests that measurements will lie within the tolerancerange of +/-15% with respect to the specified measurement. For moreinformation on this please refer to VDE0530.
6
-
8/16/2019 LAB SHEET Electric Machine
11/92
EEM2 DC machinesDC shunt-wound motors
DC shunt-wound motors
Over the next few pages you will perform the following exercisespertaining to "DC shunt-wound motors":
Connection and starting Reversing rotation direction Speed control Load characteristics
7
-
8/16/2019 LAB SHEET Electric Machine
12/92
EEM2 DC machinesDC shunt-wound motors
8
-
8/16/2019 LAB SHEET Electric Machine
13/92
EEM2 DC machinesDC shunt-wound motors
Enter the nominal data for the DC machine
Match the winding designations to the windings
Training content: "Connection and starting"
Identify the terminal connections of the motor and operate themotor as a shunt-wound motor
Read the nominal data of the motor based on the rating plate Connect the motor to the starter Be familiar with how the starter works Operate the motor with the brake Subject the motor to a load Measure armature voltage and current
UA= ____ V
IA= ____ A
UE= ____ V
IE= ____ mA
n= ____ rpm
A1/A2 __
B1/B2 __
C1/C2 __
E1/E2 __
D1/D2 __
F1/F2 __
9
-
8/16/2019 LAB SHEET Electric Machine
14/92
EEM2 DC machinesDC shunt-wound motors
Assembly instructions: " Connection and starting"
Note: setting of the DC power supply can only be performed when the motor isconnected.
More detailed information on the brake can be found in the corresponding onlinedocumentation
Circuit diagram for DC shunt-wound motor
"Connection and starting"
Assemble the circuits as specified in the following circuit diagram andset-up instructions
Include an ammeter and voltmeter in the armature circuit Switch on the brake too. This does not yet subject the motor to any
load
10
-
8/16/2019 LAB SHEET Electric Machine
15/92
EEM2 DC machinesDC shunt-wound motors
Set-up for DC shunt-wound motor
"Connection and starting"
Put the shunt-wound motor into operation
Required settings:
Starter: minimum value (0 Ω) DC power supply unit: 220V
Experiment procedure:
Put the motor into operation and observe its operating response
11
-
8/16/2019 LAB SHEET Electric Machine
16/92
EEM2 DC machinesDC shunt-wound motors
The motor demonstrates the following response:
Measure the armature current
Required settings:
Brake mode: "Torque Control"
Experiment procedure:
Apply the brake to slow the motor down to nominal speed In the process of braking measure the armature current
Make sure that the brake is not applied so hard that the motor comes to a halt
What is the magnitude of the armature current?
gfedc The motor rotates at a higher speed than the nominalspeed
gfedc The rotation direction is clockwise
gfedc The rotation direction is anti-clockwise
gfedc The switch-on current is higher than the nominalcurrent
gfedc The motor rotates at nominal speed
gfedc The current increases with increasing speed
More than oneanswer maybe correct
nmlkj The armature current corresponds approximately to
the nominal currentnmlkj The armature current is considerably higher than the
nominal current
nmlkj The armature current is considerably smaller thanthe nominal current
12
-
8/16/2019 LAB SHEET Electric Machine
17/92
EEM2 DC machinesDC shunt-wound motors
Record a load characteristic
Required settings: Starter: maximum value ( Note: 0.3 KW class ~ 47Ω; 1 KW class ~ 16 Ω)
Experiment procedure:
The motor should be subjected to the torque loads as set forth in the table Measure the armature current and armature voltage under load Enter the measured values into the table
M/Nm n/(1/min) I/A U/V0.2
0.4
0.6
0.8
1
1.2
1.4
0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5M/Nm
0
500
1000
1500
2000
2500
3000
n / m i n ¯ ¹
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0 I / A
0
50
100
150
200
250
300
U / V
13
-
8/16/2019 LAB SHEET Electric Machine
18/92
EEM2 DC machinesDC shunt-wound motors
Which of the following statements apply to the load characteristic?
What is the function of the starter?
gfedc The armature voltage is considerably reduced whenthe torque is increased
gfedc The armature current increases linearly with thetorque
gfedc The speed severely drops off once the nominaltorque is reached
gfedc The armature voltage remains practically constant
gfedc The speed remains practically constant (± 3%) in therange of the nominal torque
gfedc The speed increases at higher torques
More than oneanswer maybe correct
nmlkj The starter is primarily used for speed control
nmlkj The starter restricts the switch-on current
nmlkj The starter protects the motor from overload during
standard operation
14
-
8/16/2019 LAB SHEET Electric Machine
19/92
EEM2 DC machinesDC shunt-wound motors
Definit ion of rotation directionIf you look at the drive shaft end of the DC shunt-wound machine from theperspective of the working machine (in our case the brake), the rotating direction ispositive when it is clockwise. If the motor has two workable shaft ends, then it is the
shaft end opposite the cooling vents, collector or slip-rings that is the shaft endwhich defines the rotation direction.
Note: in the "Classic series" (0.3 kW & 1.0 kW) the rotation direction isdetermined by the rotation direction of the brake, i.e. if the asynchronous machinerotates clockwise, i.e. in the positive direction, the control unit of the brake indicatesa negative rotation direction. Thus the rotation direction displayed is always that ofthe brake.
Training content: "Rotation reversal"
Identify the difference between clockwise and anti-clockwiserotation
Put the motor into operation in both rotation directions
15
-
8/16/2019 LAB SHEET Electric Machine
20/92
EEM2 DC machinesDC shunt-wound motors
Assembly instructions: "Rotation Reversal"
Circuit diagram for DC shunt-wound motor
"Rotation Reversal"
Assemble the circuit as specified in the following circuit diagram and set-up instructions.
Include an ammeter and voltmeter in the the armature circuit. Switch on the brake. This does not yet subject the motor to any load.
16
-
8/16/2019 LAB SHEET Electric Machine
21/92
EEM2 DC machinesDC shunt-wound motors
Set-up for DC shunt-wound motor
"Rotation Reversal"
Rotation reversal
Required settings:
Starter: minimum value (0 Ω) DC power supply: 220V
Experiment procedure:
Switch on the motor and observe how it responds
Note: setting of the DC power supply can only be performed when the motor is
connected.
17
-
8/16/2019 LAB SHEET Electric Machine
22/92
EEM2 DC machinesDC shunt-wound motors
What is the motor's direction of rotation?
Switch the motor off and modify the circuit as shown by changing the polarityof the exciter coil
Turn the motor back on and observe its response
Circuit diagram for DC shunt-wound motor
"Rotation reversal" (reversed rotation direction)
What is the motor's direction of rotation now?
nmlkj The motor rotates clockwise
nmlkj The motor rotates anti-clockwise
nmlkj The motor rotates clockwise
nmlkj The motor rotates anti-clockwise
18
-
8/16/2019 LAB SHEET Electric Machine
23/92
EEM2 DC machinesDC shunt-wound motors
Assembly instructions: " Speed Control"
Note: setting of the DC power supply unit can only be performed when the motoris connected.
More detailed information on the brake can be found in the corresponding onlinedocumentation
Circuit diagram for DC shunt-wound motor
"Speed control"
Training content: "Speed Control"
Put the DC motor into operation using the field regulator Investigate speed control by modifying the armature current power Investigate operation in the field weakening range
Assemble the circuits as specified in the circuit diagram and set-up
instructions below. Include an ammeter and voltmeter in the armature circuit . Include an ammeter in the exciter circuit. Switch on the brake. This does not yet subject the motor to any load.
19
-
8/16/2019 LAB SHEET Electric Machine
24/92
EEM2 DC machinesDC shunt-wound motors
Set-up for DC shunt-wound motor
"Speed control"
20
-
8/16/2019 LAB SHEET Electric Machine
25/92
EEM2 DC machinesDC shunt-wound motors
Record characteristics " Ia and "n" as a function of "Ua
Required settings: DC power supply 220V Field regulator: minimum value (0 Ω) Brake mode: "Torque Control"
Experiment procedure:
Reduce the armature voltage in 3 stages via the adjustable DC power supply(220/190/160V)
At the same time measure the variables Iaand n and enter the measured
values into the table
Ua/V n/(1/min) Ia/A
220
190
160
150 160 170 180 190 200 210 220 230 240Ua/V
0
300
600
900
1200
1500
1800
2100
2400
2700
3000
n
/ ( 1 / m i n )
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
0.45
0.50
I a / A
21
-
8/16/2019 LAB SHEET Electric Machine
26/92
EEM2 DC machinesDC shunt-wound motors
Record the characteristic of n" as a function of "M" using the"ActiveDrive/DCMA" software
Required setting:
Brake: Industrial series: "PC Mode" Classic series: "Application Mode" ( Note: when starting the
"ActiveASMA" software you will be prompted to select "Applicationmode")
Field regulator: minimum value (0 Ω) Adjustable DC power supply unit (armature voltage): 220/190/160V DC power supply unit (exciter circuit voltage): 220V
Experiment procedure:
Start the "ActiveDrive/DCMA" software The motor should be subjected to a load equivalent to its nominal torque Label the diagram as given in the placeholder Record a total of three load characteristics for the three specified armature
circuit voltages After completing the measurement export the completed diagram with all three
characteristics and copy it into the appropriate space below
Compute the nominal torque of the motor as given by the following equation:
22
-
8/16/2019 LAB SHEET Electric Machine
27/92
EEM2 DC machinesDC shunt-wound motors
Placeholder for characteristics n(M), Ua=220/190/160V
Record the characteristics of " If " and "n" as a function of Rf
Required settings:
Brake mode: "Torque Control" Field regulator: minimum value (0 Ω) DC power supply unit: (armature & exciter circuit) 220V
23
-
8/16/2019 LAB SHEET Electric Machine
28/92
EEM2 DC machinesDC shunt-wound motors
Experiment procedure:
Switch on the DC power supply Vary the Rf value of the field regulator in 3 steps, 0%, 50% and 90% of themaximum value ( Note: 0.3 kW class ~ 2.2 kΩ; 1kW class ~ 680Ω)
At the same time measure the respective variables If and n for each step andenter the measured values into the table
Rf/Ω n/(1/min) If/mA
0 200 400 600 800 1000 1200 1400 1600 1800 2000Rf/Ω
0
300
600
900
1200
1500
1800
2100
2400
2700
3000
3300
n / ( 1 / m i n )
0
20
40
60
80
100
120
140
160
180
200
I f / m A
24
-
8/16/2019 LAB SHEET Electric Machine
29/92
EEM2 DC machinesDC shunt-wound motors
Record the characteristic " n" as a function of "M" using the"ActiveDrive/DCMA" software
Required setting:
Brake: Industrial series: "PC Mode" Classic series: "Application Mode" ( Note: when starting the
"ActiveASMA" software you will be prompted to select "Applicationmode")
Field regulator: minimum value (0 Ω) DC power supply unit: (armature & exciter circuit) 220V
Experiment procedure:
Start the "ActiveDrive/DCMA" software The motor should be subjected to a load up to its nominal torque Label the diagram as appropriate in the placeholder below Record three characteristics are recorded in sequence for 3 different field
regulator values (Rf ), one each at 0%, 50% and 90% of the maximum setting( Note: 0.3 kW class ~ 2,2 kΩ; 1 kW class ~ 680 Ω)
After completing the measurement export the graph with all 3 characteristicsand copy it into the placeholder below
Placeholder for characteristics n(M), Rf = 0%/50%/90% of the maximum setting
25
-
8/16/2019 LAB SHEET Electric Machine
30/92
EEM2 DC machinesDC shunt-wound motors
Which statements are true of the speed variation?
gfedc A reduction of the armature voltage leads to a drop in
speedgfedc A reduction of the exciter current leads to a drop in
speed
gfedc An increase of the armature voltage leads to a dropin speed
gfedc A decrease of exciter current leads to an increase inspeed
More than oneanswer maybe correct
26
-
8/16/2019 LAB SHEET Electric Machine
31/92
EEM2 DC machinesDC shunt-wound motors
Setup diagram: "Load Characteristic"
Note: setting of the DC power supply can only be carried out when the motor isconnected
More detailed information on the brake and the software used can be found in theappropriate online documentation
Circuit diagram for DC shunt-wound motor
"Load characteristic"
Training content: " Load characteristic"
Record the motor's load characteristic Calculate the nominal torque Determine the highest degree of efficiency Recognise how the motor responds to loads
Assemble the circuit as specified in the following circuit diagram and set-
up instructions Include an ammeter and voltmeter in the armature/exciter circuit Switch the brake on too. This does not yet subject the motor to any load
27
-
8/16/2019 LAB SHEET Electric Machine
32/92
EEM2 DC machinesDC shunt-wound motors
Set-up for DC shunt-wound motor
"Load characteristic"
28
-
8/16/2019 LAB SHEET Electric Machine
33/92
EEM2 DC machinesDC shunt-wound motors
Record the motor's load characteristics with the aid of the"ActiveDrive/DCMA" software
Required setting:
Brake: Industrial series: "PC Mode" Classic series: "Application Mode" ( Note: when starting the
"ActiveASMA" software you will be prompted to select "Applicationmode")
DC power supply unit: (armature & exciter circuit) 220V
Experiment procedure:
Start the "ActiveDrive/DCMA" software The motor should be subjected to a load up to 1.5 times its nominal torque Label the diagram as given in the placeholder The following parameters should be recorded: The degree of efficiency η(M) (η
=> "Eta"), of the armature current IA, the power output P2 and the speed n(M) Before starting the measurement you must have answered the question
concerning the nominal torque, which you should have determined inthe "speed control" experiment
After completing the measurement export the generated graph and copy it into
the corresponding placeholder below Determine from the diagram the highest degree of efficiency obtainable
29
-
8/16/2019 LAB SHEET Electric Machine
34/92
EEM2 DC machinesDC shunt-wound motors
What is the nominal torque?
Placeholder for graph η(M) (η => „Eta“), IA(M), P2(M), n(M)
What is the maximum efficiency "η" for the shunt-wound motor?
MN= ____
Nm
η= ____ % approx.
30
-
8/16/2019 LAB SHEET Electric Machine
35/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Separately excited DC shunt-wound generator
Voltage control (field regulating range) Voltage polarity Load characteristics
Over the next few pages you will be conducting the followingexercises on a "separately excited DC shunt-wound generator":
31
-
8/16/2019 LAB SHEET Electric Machine
36/92
EEM2 DC machinesDC shunt-wound generators, separately excited
32
-
8/16/2019 LAB SHEET Electric Machine
37/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Assembly instructions: " Voltage Control"
Note: setting of the DC power supply can only be carried out when the exciter
circuit is connected
More detailed information on the brake can be found in the corresponding onlinedocumentation
Circuit diagram for DC shunt-wound generator, separately excited
"Voltage Control"
Training contents: "Voltage Control"
Connect up the machine as a separately excited DC shunt-wound generator
Recognise which variables affect the output voltage of thegenerator
Determine the output voltage as a function of the speed Understand the purpose of the field regulator and how it works
Assemble the circuit as specified in the following circuit diagram and set-up instructions
Include an ammeter and voltmeter in the exciter circuit Set the field regulator to the value 0 Ω Set the DC power supply to a voltage of 220 V In this experiment the brake is used as a drive motor
33
-
8/16/2019 LAB SHEET Electric Machine
38/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Set-up for DC shunt-wound generator, separately excited
"Voltage control"
34
-
8/16/2019 LAB SHEET Electric Machine
39/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Record the characteristic of " UG" as a function of " n" for different excitercurrents
Required settings:
Brake mode: "Speed Control" Field regulator: maximum value ( Note: 0.3 kW class ~ 2.2 kΩ; 1 kW
class ~ 680 Ω) DC power supply unit: (exciter circuit) 220 V
Experiment procedure:
Put the generator into operation First run the drive motor up to a speed of 3000 rpm Use the field regulator to set the exciter currents specified in the table Begin at Ierr.= 0 mA Measure the generator voltage UG produced at each speed as you lower the
speed step by step (see table)
Ierr.=0mA Ierr.=50mA Ierr.=70mA Ierr.=90mA
n/(1/min) Ug/V Ug/V Ug/V Ug/V
30002800
2600
2400
2200
2000 2200 2400 2600 2800 3000 3200n/(1/min)
0
50
100
150
200
250
300
350
U g ( I e r r = 0 ) / V
0
50
100
150
200
250
300
350
U g ( I e r r
. = 5 0 m
A ) / V
0
50
100
150
200
250
300
350
U g ( I e r r
. = 7 0 m
A ) / V
0
50
100
150
200
250
300
350
U g ( I e r r
. = 9 0 m
A ) / V
35
-
8/16/2019 LAB SHEET Electric Machine
40/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Why does the generator produce a low voltage at an exciter current of I = 0mA?
Which of the following variables have an immediate impact on the generatorvoltage?
nmlkj The voltage results from the inaccuracy of themeasuring instruments being used
nmlkj The generator charges up statically due to therotating motion of the rotor. This surge in charge ismeasurable as a low voltage
nmlkj This voltage is caused by the residual magnetisation(remanence) of the exciter field
nmlkj The exciter winding's coercive field strength is notsufficient to generate a low voltage when it is off
gfedc Exciter field voltage
gfedc Speed
gfedc No-load torque
gfedc Exciter current
gfedc Polarity of the armature winding
More than oneanswer maybe correct
36
-
8/16/2019 LAB SHEET Electric Machine
41/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Assembly instructions: " Voltage Polarity"
Note: setting of the DC power supply unit can only be performed when the excitercircuit is connected
More detailed information on the brake can be found in the corresponding online
documentation
Circuit diagram for DC shunt-wound generator, separately excited
"Voltage polarity"
Training contents: "Voltage Polarity"
Recognise the relationship between the polarity of the connection ofthe exciter winding, the rotation direction of the generator and howthey relate to the resulting generator voltage
Assemble the circuits as specified in the circuit diagram and set-upinstructions below
Include an ammeter and voltmeter in the exciter circuit. Set the field regulator to the value 0 Ω Set a voltage of 220 V on the DC power supply In this experiment the brake is used as a drive motor
37
-
8/16/2019 LAB SHEET Electric Machine
42/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Set-up for DC shunt-wound generator, separately excited
"Voltage polarity"
38
-
8/16/2019 LAB SHEET Electric Machine
43/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Properties of a generator when the polarity of the exciter winding is reversedand when the rotation direction is reversed
Required settings:
Brake mode: "Speed Control" Field regulator: minimum value (0 Ω) DC power supply unit: (exciter circuit) 220 V
Experiment procedure:
Put the generator into operation First run the drive motor up to a speed of 2000 rpm Measure the generator voltage UG Now change the polarity of the exciter winding and then the rotation direction
of the drive motor Measure the generator voltage UG after each modification
Which of the following statements is true?
nmlkjThe polarity of the generator voltage is independentof the generator's rotation direction
nmlkj The polarity of the exciter winding and the rotationdirection of the generator are determined by thepolarity of the generator voltage
nmlkj The polarity of the generator voltage cannot bechanged as it is fixed to the same polarity by themanufacturer
39
-
8/16/2019 LAB SHEET Electric Machine
44/92
EEM2 DC machinesDC shunt-wound generators, separately excited
40
-
8/16/2019 LAB SHEET Electric Machine
45/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Training contents: "Load Characteristics"
Record and interpret the load characteristics of a DC shunt-woundgenerator
Understand the relationship between the generator voltage,armature current, exciter current and speed
41
-
8/16/2019 LAB SHEET Electric Machine
46/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Assembly instructions: " Load Characteristics"
Note: setting of the DC power supply unit can only be performed when the excitercircuit is connected
More detailed information on the brake can be found in the corresponding onlinedocumentation
Circuit diagram for shunt-wound generator, separately excited
"Load Characteristics"
Assemble the circuit as specified in the circuit diagram and set-upinstructions
Include an ammeter and voltmeter in the exciter/armature circuit The armature circuit is to be ted to the load resistor In this experiment the brake is used as a drive motor
42
-
8/16/2019 LAB SHEET Electric Machine
47/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Set-up for DC shunt-wound generator, separately excited
"Load characteristics"
43
-
8/16/2019 LAB SHEET Electric Machine
48/92
EEM2 DC machinesDC shunt-wound generators, separately excited
Record the load characteristics of the generator with various exciter currents
Required settings: Brake mode: "Speed Control" DC power supply unit: (exciter circuit) 220V Field regulator: minimum setting (0 Ω) Load resistor: maximum ( Note: 0.3 kW class ~ approx. 1 kΩ; 1 kW class ~
approx. 440 Ω)
Experiment procedure:
The drive motor is to be run up to a speed of 3000 rpm with the generator
operating without a load (load resistor set to maximum) Record the load characteristics based on the armature currents specified in
the table with 2 different nominal exciter currents (50% and 100% of thenominal exciter current)
Measure the variables UG (generator voltage) and P2 (power output) when thearmature current IG is increased step by step
Increase the armature current by reducing the load resistance Calculate the power output and enter all the measured values into the tables
The electrical power output is computed as follows:
P2=UG*IG; UG[V], IG[A], P2[W]
44
-
8/16/2019 LAB SHEET Electric Machine
49/92
EEM2 DC machinesDC shunt-wound generators, separately excited
100% of nominal exciter current
50% of nominal exci ter current
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5Ig/A
0
50
100
150
200
250
300
350
U g / V
0
50
100
150
200
250
300
350
P 2 / W
Ig/A 0.3 0.6 0.8 1 1.2 1.4
Ug/V
P2/W
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5Ig/A
0
50
100
150
200
250
300
350
U g / V
0
50
100
150
200
250
300
350
P 2 / W
45
-
8/16/2019 LAB SHEET Electric Machine
50/92
EEM2 DC machinesDC shunt-wound generators, separately excited
46
-
8/16/2019 LAB SHEET Electric Machine
51/92
EEM2 DC machinesDC shunt-wound generators, self-excited
DC shunt-wound generator,
self-excited
Rotation direction and polarity Load characteristics
Over the next few pages you will be conducting exercises on a "self-excited DC shunt-wound generator":
47
-
8/16/2019 LAB SHEET Electric Machine
52/92
EEM2 DC machinesDC shunt-wound generators, self-excited
48
-
8/16/2019 LAB SHEET Electric Machine
53/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Assembly instructions: " Rotation Direction and Polarity"
Note: setting of the DC power supply unit can only be carried out when theexciter circuit is connected
More detailed information regarding the brake can be found in the correspondingonline documentation
Circuit diagram for DC shunt-wound generator, self-excited
"Rotation direction and polarity"
Training content: "Rotation Direction and Polarity"
Recognise how the generator voltage results from the polarity of theexciter winding and the generator's rotation direction
Assemble the circuits as specified in the circuit diagram and set-upinstructions below
Include an ammeter and voltmeter in the armature circuit Include an ammeter in the exciter circuit Connect the armature circuit to the load resistor In this experiment the brake is used as a drive motor
49
-
8/16/2019 LAB SHEET Electric Machine
54/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Set-up for DC shunt-wound generator, self-excited
"Rotation direction and polarity"
Properties of the generator when rotation direction is reversed
Required settings:
Brake mode: "Speed Control" Field regulator: minimum setting (0 Ω) Load resistor: maximum ( Note: 0.3 kW class ~ 1 k Ω; 1 kW class ~ 440 Ω)
50
-
8/16/2019 LAB SHEET Electric Machine
55/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Experiment procedure:
Put the generator into operation by running the drive motor up to a speed ofapprox. 3000 rpm Measure the generator voltage UG and enter this into the box corresponding to
the rotation direction Now reverse the rotation direction of the drive motor Finally measure the generator voltage UG again and enter this value again into
the corresponding box
The generator voltage for anti-clockwise rotation of the generator is:
The generator voltage for clockwise rotation of the generator is:
Which of the following statements is true of the generator voltage?
UG= ____
V
UG= ____ V
nmlkj The amplitude of the generator voltage is the samefor both rotation directions
nmlkj When rotating clockwise the ampltiude of thegenerator voltage is the highest
nmlkj For both rotation directions the generator voltageis zero
nmlkj During clockwise rotation the amplitude of the
generator voltage is somewhat lower than for anti-clockwise rotation
51
-
8/16/2019 LAB SHEET Electric Machine
56/92
EEM2 DC machinesDC shunt-wound generators, self-excited
52
-
8/16/2019 LAB SHEET Electric Machine
57/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Assembly instructions: " Load Characteristics"
More detailed information on the brake can be found in the corresponding onlinedocumentation
Circuit diagram for DC shunt-wound generator, self-excited
"Load characteristics"
Training content: "Load Characteristics"
Record and interpret the load characteristics for a self-excited DCshunt-wound generator
Understand the relationship between the generator voltage, excitercurrent and speed
Assemble the circuits as specified in the circuit diagram and set-up
instructions below Include an ammeter and voltmeter in the armature circuit Include an ammeter in the exciter circuit Connect the armature circuit to the load resistor In this experiment the brake is used as a drive motor
53
-
8/16/2019 LAB SHEET Electric Machine
58/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Set-up for DC shunt-wound generator, self-excited
"Load Characteristic"
54
-
8/16/2019 LAB SHEET Electric Machine
59/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Record the load characteristic o f the generator
Required settings: Brake mode: "Speed Control" Field regulator: minimum setting (0 Ω) Load resistor: maximum ( Note: 0.3 kW class ~ approx. 1 kΩ; 1 kW class ~
approx. 440 Ω)
Experiment procedure:
Put the generator into operation First run the drive motor up to a speed of 3000 rpm Make sure that you have the correct rotation direction of the motor, as
determined in the experiment "rotation direction and polarity" In no-load operation the nominal exciter current must be set with the aid of the
field regulator The the load resistance should be lowered in several steps (see table),
thereby increasing the load In the process measure the generator voltage UG, the armature current IG and
use these measurements to compute the power output P2 Transfer all of these values into the table
55
-
8/16/2019 LAB SHEET Electric Machine
60/92
EEM2 DC machinesDC shunt-wound generators, self-excited
Select those statements that are true about the load characteristic
Ra/Ω Ug/V Ig/A P2/W
1000
500250
150
100
50
22
0 100 200 300 400 500 600 700 800 900 1000Belastungswiderstand R/Ohm
0.0
0.3
0.6
0.9
1.2
1.5
I g / A
0
50
100
150
200
250
300
U g / V
0
50
100
150
200
250
300
P 2 / W
gfedc P2 is dependent on the load resistor
gfedc As R A rises P2 also increases continuously
gfedc The characteristics for P2 & IG have the same pattern
in terms of their curvegfedc The generator voltage UG drops with increasing load
gfedc The armature current is constant
More than one
answer maybe correct
56
-
8/16/2019 LAB SHEET Electric Machine
61/92
EEM2 DC machinesDC series-wound motors
DC series-wound motors
Connection and starting Reversing rotation direction Load characteristics for various voltages
Over the next few pages you will be conducting the following exerciseson "DC series-wound motors":
57
-
8/16/2019 LAB SHEET Electric Machine
62/92
EEM2 DC machinesDC series-wound motors
58
-
8/16/2019 LAB SHEET Electric Machine
63/92
EEM2 DC machinesDC series-wound motors
Assembly instructions: " Connection and Starting"
Note: setting of the DC power supply unit can only be carried out when the motor
is connected
More detailed information on the brake can be found in the corresponding onlinedocumentation
Circuit diagram for DC series-wound motor
Training content: "Connection and Starting"
Identify the terminal connections of the motor and operate themotor as a shunt-wound motor
Put the motor into operation with the brake Connect the motor to the starter Be familiar with how the starter works Measure the motor voltage and the motor current Determine the degree of efficiency
Assemble the circuit as specified in the following circuit diagram andset-up instructions
Include an ammeter and voltmeter in the motor circuit Switch on the brake too. This does not yet subject the motor to any load
59
-
8/16/2019 LAB SHEET Electric Machine
64/92
EEM2 DC machinesDC series-wound motors
"Connection and Starting"
Set-up for of the DC series-wound motor
"Connection and Starting"
60
-
8/16/2019 LAB SHEET Electric Machine
65/92
EEM2 DC machinesDC series-wound motors
Determine the nominal efficiency
Required settings: Brake mode: "Torque Control" ( Note: The brake should definitely be active) Starter: minimum value (0 Ω) DC power supply unit: 220 V
Experiment procedure:
Brake the motor down to its nominal torque In the process measure the motor current Use the provided equation to compute the efficiency of the motor based on the
rated data and the measured variables
Make sure that the motor is not operated without any load, as otherwise themotor could start to "race"
The efficiency is defined as:
P2=Mn*ω, P1=UM*IM, ω=2*π*n
What is the efficiency "η" of the series-wound motor with a nominal load?
η=P2/P1
η= ____
% approx.
61
-
8/16/2019 LAB SHEET Electric Machine
66/92
EEM2 DC machinesDC series-wound motors
Record a load characteristic (with starter)
Required settings: Brake mode: "Torque Control" (the brake should definitely be active) Starter: minimum value (0 Ω) DC power supply unit: 220 V
Experiment procedure:
Brake the motor down to 0.5 times its nominal torque Now adjust the starter in 5 steps from 0 up to 100% of its maximum value (
Note: 0.3 kW class ~ 47 Ω; 1 kW class ~ 16 Ω) At the same time measure the motor current and voltage Transfer the measurement values into the table
Ra/Ω n/(1/min) I/A U/V
0 5 10 15 20 25 30 35 40 45 50Belastungswiderstand R/Ω
0
500
1000
1500
2000
2500
3000
n / ( 1 / m i n )
0
50
100
150
200
250
300
U / V
0.0
0.3
0.6
0.9
1.2
1.5 I / A
62
-
8/16/2019 LAB SHEET Electric Machine
67/92
EEM2 DC machinesDC series-wound motors
Definit ion of rotation directionIf you look at the drive shaft end of the DC shunt-wound machine from theperspective of the working machine (in our case the brake), the rotating direction ispositive when it is clockwise. If the motor has two workable shaft ends, then it is the
shaft end opposite the cooling vents, collector or slip-rings that is the shaft endwhich defines the rotation direction.
Note: in the "Classic series" (0.3 kW & 1.0 kW) the rotation direction isdetermined by the rotation direction of the brake, i.e. if the asynchronous machinerotates clockwise, i.e. in the positive direction, the control unit of the brake indicatesa negative rotation direction. Thus the rotation direction displayed is always that ofthe brake.
Training content: "Rotation Reversal"
Recognise the difference between clockwise and anti-clockwiserotation
Put the motor into operation in both directions
63
-
8/16/2019 LAB SHEET Electric Machine
68/92
EEM2 DC machinesDC series-wound motors
Assembly instructions: "Rotation Reversal"
Note: setting of the DC power supply unit can only be performed with the motorconnected
More detailed information can be found in the corresponding onlinedocumentation
Circuit diagram for DC series-wound motor
"Rotation Reversal"
Assemble the circuits as specified in the circuit diagram and set-upinstructions below Include an ammeter and voltmeter in the motor circuit Switch on the brake too. This does not yet subject the motor to any
load Set the starter to a setting of 0 Ω Set a voltage of 220 V on the DC power supply unit
64
-
8/16/2019 LAB SHEET Electric Machine
69/92
EEM2 DC machinesDC series-wound motors
Set-up for DC series-wound motor
"Rotation Reversal"
Determining the respective rotation direction
Required settings:
Brake mode: "Torque Control" (the brake should definitely be active) Starter: maximum setting ( Note: 0.3 KW class ~ 47 Ω; 1 KW class ~ 16 Ω) DC power supply unit: 220V
Experiment procedure:
Put the motor into operation and observe the following
Make sure that the motor is not operated without any load, as otherwise it could"race"
65
-
8/16/2019 LAB SHEET Electric Machine
70/92
EEM2 DC machinesDC series-wound motors
What is the motor's rotation direction?
Now modify the circuit diagram as shown below:
Circuit diagram for DC series-wound motor
"Rotation Reversal"
(reversed rotation direction)
What is the motor's rotation direction now?
nmlkj The motor rotates anti-clockwise
nmlkj The motor rotates clockwise
nmlkj The motor rotates clockwise
nmlkj The motor rotates counterclockwise
66
-
8/16/2019 LAB SHEET Electric Machine
71/92
EEM2 DC machinesDC series-wound motors
Assembly instructions: " Load Characteristics"
Note: setting of the DC power supply unit can only be performed when the motoris connected
More detailed information regarding the brake can be found in the correspondingonline documentation
Circuit diagram for DC series-wound motor"Load Characteristics"
Training content: "Load Characteristics"
Analyse and understand the relationship between the load of theseries-wound motor and its speed and armature current
Assemble the circuits as specified in the circuit diagram and set-upinstructions below
Include an ammeter and voltmeter in the motor circuit Switch on the brake too. This does not yet subject the motor to any load
67
-
8/16/2019 LAB SHEET Electric Machine
72/92
EEM2 DC machinesDC series-wound motors
Set-up for DC series-wound motor
"Load Characteristics"
68
-
8/16/2019 LAB SHEET Electric Machine
73/92
EEM2 DC machinesDC series-wound motors
Record the load characteristics of the motor using the "ActiveDrive/DCMA"software
Required setting:
Brake: Industrial series: "PC Mode" Classic series: "Application Mode" ( Note: when starting the
"ActiveASMA" software you will be prompted to select "Applicationmode"
DC power supply unit: (motor circuit) 220 V
Experiment procedure:
Start the "ActiveDrive/DCMA" software The motor should be subjected to a load up to 1.5 times its nominal torque Label the graph as given in the placeholder below In the first graph the following parameters are to be plotted: The motor current
I(M), the motor voltage U(M) and the speed n(M) In the second graph the following parameters are to be plotted: the consumed
electical power and the mechanical output power (P1(M), P2(M)) as well as theresulting efficiency η(M) (η => "Eta")
After completing the measurements export the generated graphs and copy
them into the placeholders below Determine the highest possible efficiency from the second graph
69
-
8/16/2019 LAB SHEET Electric Machine
74/92
EEM2 DC machinesDC series-wound motors
Placeholder for graph U(M), I(M), n(M)
Placeholder for graph η(M) (η => "Eta"), P1(M), P2(M)
70
-
8/16/2019 LAB SHEET Electric Machine
75/92
EEM2 DC machinesDC series-wound motors
What is the maximum efficiency "η" for the series-wound motor?
Which of the following statements regarding the load graphs are true?
Why is it imperative that a series-wound motor is never operated without load?
η= ____
% approx.
gfedc The exciter field and the armature current are lowwhen the loads are also low
gfedc The armature current increases linearly with the load
gfedc The efficiency "η" is constant
gfedc The speed is inversely proportional to the torque
gfedc Under low load the speed and armature currentlevels increase
gfedc The rotation speed drops off severely with increasingload
More than oneanswer maybe correct
nmlkj Without a load the speed drops off at a rapid rate
nmlkj Without a load the motor can start to "race"
71
-
8/16/2019 LAB SHEET Electric Machine
76/92
EEM2 DC machinesDC series-wound motors
72
-
8/16/2019 LAB SHEET Electric Machine
77/92
EEM2 DC machinesDC compound-wound motors
DC compound wound motor
Load characteristics for different compound ratios
On the next page the following exercise will be conducted on the DCcompound-wound motor:
73
-
8/16/2019 LAB SHEET Electric Machine
78/92
EEM2 DC machinesDC compound-wound motors
74
-
8/16/2019 LAB SHEET Electric Machine
79/92
EEM2 DC machinesDC compound-wound motors
Training content: " Load Characteristics for Different
Compound Winding Ratios" Identify the terminal connections of the motor and operate the
motor as a DC compound-wound motor Put the motor into operation with the brake Record the load characteristics for different series-wound
components Identify the difference between over-compounded, normal and
under-compounded motors Compare the response of acompound-wound machine with
series and shunt-wound machines
75
-
8/16/2019 LAB SHEET Electric Machine
80/92
EEM2 DC machinesDC compound-wound motors
Assembly instructions: " Load Characteristics"
Note: setting of the DC power supply unit can only be performed when the motoris connected
More detailed information regarding the brake can be found in the correspondingonline documentation
Circuit diagram for compound-wound machine
"Load characteristics for different compound winding ratios"
(100% series-wound component – "over-compounded“)
Assemble the circuit as specified in the following circuit diagram andset-up instructions
Include an ammeter and voltmeter in the motor circuit Switch on the brake too. This does not yet subject the motor to any
load
76
-
8/16/2019 LAB SHEET Electric Machine
81/92
EEM2 DC machinesDC compound-wound motors
Set-up for compound wound machine
"Load characteristic for different compound winding ratios"
(100% series-wound component – " over-compounded“)
77
-
8/16/2019 LAB SHEET Electric Machine
82/92
EEM2 DC machinesDC compound-wound motors
Record the load characteristics of the motor wi th various compoundratios using the software "Act iveDrive/DCMA"
Required settings:
Brake: Industrial series: "PC Mode" Classic series: "Application Mode" ( Note: when starting the "DSMA"
software you will be prompted to select "Application mode") DC power supply unit: (motor circuit) 220 V
Experiment procedure:
Start the "ActiveDrive/DCMA" software The motor should be subjected to a load up to 1.5 times its nominal torque Label the graph as specified in the placeholder below You should perform three measurements for different compound winding
ratios (100%, 70%, 30% series-wound component) recording two graphs,each with different parameters
In the first graph the following parameters are to be plotted: the motor current I
(M), the motor voltage U(M) and the speed n(M) In the second graph the following parameters should be plotted: consumed
electrical power and the mechanical power output (P1(M), P2(M)), as well as
the resulting degree of efficiency η(M) (η => „Eta“) Export the plotted graph and copy it into the placeholder below Determine the optimum efficiency in each case from the second graph
78
-
8/16/2019 LAB SHEET Electric Machine
83/92
EEM2 DC machinesDC compound-wound motors
Placeholder for graph U(M), I(M), n(M) (100% series-wound component – "over-compounded“)
Placeholder for graph η(M) (η => „Eta“), P1(M), P2(M) (100% series-wound component – "over-compounded“)
79
-
8/16/2019 LAB SHEET Electric Machine
84/92
EEM2 DC machinesDC compound-wound motors
Circuit diagram for compound-wound machine
"Load characteristics for different compound winding ratios"
(70% series-wound component – "normal compounded“)
Placeholder for graph U(M), I(M), n(M)
(70% series-wound component – "normally compounded“)
80
-
8/16/2019 LAB SHEET Electric Machine
85/92
EEM2 DC machinesDC compound-wound motors
Placeholder for graph η(M) (η => "Eta"), P1(M), P2(M) (70% series-wound component – "normally compounded“)
Circuit diagram for compound-wound machine
"Load characteristics for different compound winding ratios"
(30% series-wound component – "under-compounded“)
81
-
8/16/2019 LAB SHEET Electric Machine
86/92
EEM2 DC machinesDC compound-wound motors
Placeholder for graph U(M), I(M), n(M) (30% series-wound component – "under-compounded“)
Placeholder for the graph η(M) (η => „Eta“), P1(M), P2(M) (30% series-wound component – "under-compounded“)
82
-
8/16/2019 LAB SHEET Electric Machine
87/92
EEM2 DC machinesDC compound-wound motors
Which compound winding ratio produces the highest efficiency "η"?
What is the optimum efficiency "η" of the compound-wound motor at theappropriate compound winding ratio?
Based on the graphs, which statements are true of the compound wound motor?
nmlkj 100% shunt-wound/70% series-wound
nmlkj 100% shunt-wound/100% series-wound
nmlkj 100% shunt-wound/30% series-wound
η= ____
% approx.
gfedc The speed of the compound-wound motor under loaddrops more severely than for the shunt-wound motorregardless of the compound winding ratios
gfedc The compound-wound motor can start to "race" in
the no-load state just like the series-wound motorgfedc The higher the series-wound component, the lower
the speed drop under load
gfedc The smaller the series-wound component, the lowerthe speed drop under load
gfedc If the polarity of the series-wound winding isreversed, the speed increases, due to the fact thatthe shunt-wound winding is weakened
gfedc When the polarity is reversed in the series-wound
winding, the speed increases because the field of theshunt wound winding is amplified
More than oneanswer maybe correct
83
-
8/16/2019 LAB SHEET Electric Machine
88/92
EEM2 DC machinesDC compound-wound motors
84
-
8/16/2019 LAB SHEET Electric Machine
89/92
EEM2 DC machinesCopyright
Copyr ight © 2004-2006 LUCAS-NÜLLE GmbH.
This course "EEM 2 DC machines" is protected by copyright. All rightspertaining thereto are reserved. Any reproduction of the document as a file or inwritten form be it photocopy, microfilm or any other method or conversion into amachine-compatible language, in particular for data processing systems, without theexpressed written approval of the LUCAS-NÜLLE GmbH is strictly forbidden.
The software as described above is made available on the basis of a generallicensing agreement or in the form of a single license. The use or reproduction of thesoftware is only permitted in strict compliance with the contractual terms statedtherein.
If changes have been performed in a manner which was not strictly authorised bythe LUCAS-NÜLLE GmbH, any product liability or warranty claims pertaining theretoare null and void.
Congratulations!
This is the last page. You have completed the course "EEM 2 DCmachines".
85
-
8/16/2019 LAB SHEET Electric Machine
90/92
-
8/16/2019 LAB SHEET Electric Machine
91/92
-
8/16/2019 LAB SHEET Electric Machine
92/92
16