Page 1: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

Tender Report for Supply and installation of LAN in *Biomedical Imaging and

Bioinformatics Lab*

General Scope of Work: Supply and installation of Computer Laboratory setup in MIU

Location of Installation:ISI Kolkata,203, B.T. Road,Kolkata – 700108,West Bengal, INDIA BILL OF MATERIALS

Sl no. Item Quantity1 Category 6A Information

Outlet22 pc

2 Cat 6A UTP Cable ( Each box 305mtrs)

1 box

3 Cisco UC Phone 6945 Charcoal Standard Handset

1 pc

4 Cat 6A Patch Panel (Unloaded)

1 pc

5 Single Port Face Plate 11 pc 6 Back Box 11 pc7 Service8.(i) Cat 6A cable Laying through

PVC conduit including supply of PVC Conduit

300mtr

8.(ii) Cat 6A I/O termination 228.(iii) Face Plate & Back Box

installation11

Page 2: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

DETAIL SPECIFICATION

CAT 6A Information Outlet

1. Featuresa. Electrical performance guaranteed to meet or exceed the channel specifications of

Amendment 1 to ISO/IEC 11801 : 2002 Class EA and ANSI/TIA-568-C.2 Category

b. 6A when used as part of a CAT 6 A UTP Channel in registered installationsc. Crossing of straddling pair contacts enables efficient Alien Crosstalk reduction in

the channeld. Should be non-keystone product.e. Snaps into standard faceplates, surface-mount boxes, consolidation point boxes,

and Modular Panel.f. Can also be mounted either at 90 degrees (straight) or 45 degrees (angled) in any

faceplateg. Universal design and label supports both T568 A & B wiringh. IDC connector terminations on rear of base allow quick and easy installation of

22 to 24 AWG cablei. UL® and cUL listedj. Can support network line speeds up to at least 10 gigabits per secondk. Qualifies for the 20-Year Extended Product Warranty and Applications Assurancel. RoHS Compliant

1. Physical Specifications:a. Dimensions: 0.8 x 0.8 x 1.2 in (2.0 x 2.0 x 3.1 cm) Universal A/B labelingb. Plastic Material: High-impact, flame retardant, thermoplasticc. Flammability Rating: UL-rated 94 V-0d. Operating Temperature: 1 4°F to 1 40°F (-10°C to 60°C)e. Storage Temperature: -40°F to 1 58°F (-40°C to 70°C)f. Humidity 95% (non-condensing)g. Contact Material & Planting: Copper alloy, Planting: Gold over nickelh. Under plate. Insulation displacement connectors accept solid ori. Stranded wire (7strands)j. Nominal Solid Conductor Diameter: 0.016 in to 0.025 ink. (0.40 mm to 0.64mm) (26 to 22 AWG)l. Nominal Stranded Conductor Diameter: 0.020 in to 0.025 in m. (0.51 mm to 0.64 mm) (24 to 22 AWG)n. Insulation Size: 0.030 in to 0.046 in (0.76 mm to 1.1 7 mm)o. Outlet Wires: Copper alloy, 50 micro-inch (1.27 microns) hard gold plating over 1

00 micro-inch (2.54 microns) nickel under plate

Page 3: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

p. Plug Retention Force: 30 lbs (133 N) minimum between modular plug and jackq. Plug Insertion Life: 750 minimum insertions of an 8-position IEC 60603-7

compliant plug

CAT 6A Cable

1. Featuresa. Outer diameter 0.285 in. (7.24mm)b. Packaged in we-tote box.c. 4 pair construction with finned inner jacket surface and isolator provides the extra

margin of performance required for high band-with applicationsd. The cable should be round in shapee. In the Channel, the cable length should be as low as 3 meter and 5 meter in total

channel.f. The Channel shouldg. Non-Plenum constructionh. ETL Listed – Riser rated CMR and CMGi. Electrical performance guaranteed to meet or exceed the channel specifications of

Amendment 1 to ISO/IEC 1180:2001 Class EA, and ANSI/TIA-568-C.2 Category 6A up to 500 MHz when used as part of a CAT 6 A U/UTP Channel installations.

j. Can support network line speeds up to 10 gigabits per secondk. Qualifies for the 20- Year Extended Product Warranty and Applications

Assurance l. RoHS Compliantm. The cable, patch cords and connecting hardware shall be UTP components that do

not include internal or external shields, or drain wires.

Category 6A Patch Panel

1.1 Category 6A modular patch panels

1. 24 port patch panels with 110 IDC connector terminations on rear2. The Electrical performance guaranteed to meet or exceed the channel

specifications of Amendment 1 to ISO/IEC 11801:2002 Class EA and ANSI/TIA-568-C.2 Category

3. The panel shall have vertical and horizontal cord organizers available as to improve patch cord management.

4. The panel shall be available in 24-port configurations with universal A/B labeling and 110 connector terminations on rear of panel allowing for quick and easy installation of 22 to 24 AWG cable.

5. The panel shall have a black powder finish over high-strength steel.6. The pane; shall be equipped with s removable rear mounted cable

management bar and front and rear labels.

Page 4: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

7. The panel shall be UL listed, UL-C certified and ACA approved.8. The panel shall support network line speeds in excess of 10 gigabit

per second and be backward compatible with Category 6, 5e, 5 and 3 cords and cables.

9. The panels shall be either wall or 19-inch rack mountable.

2. Electrical Specifications:a. Insulation Resistance: 500 MΩ minimumb. Current Rating: 1.5 A at 68°F (20°C)c. Dielectric Withstand Voltage: 1,000 VAC RMS, 60 Hz minimum, contact-to-

contact and 1,500 VAC RMS, 60 Hz minimum to exposed conductive surfaced. UL and cUL Listed

Faceplates

Flush-mounted modular faceplates Faceplates shall be available in single, duplex, triplex, quadplex, or sixplex

arrangement in a single gang configuration. Faceplate outlet openings shall be numbered on both sides for installation

and maintenance identification. Faceplates shall be High-impact, flame retardant, UL-rated 94V-0

thermoplastic.

Page 5: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

Consortium:

If the Bidder is not a manufacturer he should provide documentary evidence (e.g. Manufacturers’ Authorization Form) for having tied up with all the participating agencies.

Bid Currencies: Bids are to be quoted in Indian Rupees only.

Cancellation of Tender:

1. The Institute may cancel the tender processing at any point of time prior to the issuance of purchase order without assigning any reason whatsoever for unforeseen and unavoidable circumstances. 2. The Institute may also cancel the tender processing for want of any participating Bidder or if all the participating Bidders fail to qualify eligibility in terms with technical or other reasons.

Technical & commercial bids should be submitted in separate sealed envelopes mentioning the contents on it. Any Technical Bid not containing the above specifications may be rejected. The Technical Bid should not contain any price information, such proposal will be rejected.

Page 6: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

Bill of Material(To be included in Technical Bid)

The Bidder should provide Bill of Material (details of all Modules / Components of Software including those bought-out, off-the-shelf or third-party products / items required) Module-wise, in the following format.

Module/Item Description Make/ Model/ Version Part Number

Principal Vendor/ Manufacturer

Quantity/ No. of Licenses per installation

Signature of Bidder : Name :

Business address :

Place :

Date:

Page 7: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

Bill of Material(To be included in Commercial Bid)

Module/ Item

Make/ Model/ Version

Part Number

Principal Vendor/

Manufacturer

Quantity/ No. of

Licenses per

installation

Unit Price

Total Price

without Tax

Tax % Tax Estimate

Total Price with Tax

Signature of Bidder :

Name :

Business address :

Place :

Date:

Page 8: lab tendor.docx · Web viewBengal, INDIA BILL OF MATERIALS Sl no. Item Quantity 1 Category 6A Information Outlet 22 pc 2 Cat 6A UTP Cable ( Each box 305mtrs) 1 box 3 Cisco UC Phone

Quotation Address :

To Prof. Pradipta MajiMachine Intelligence Unit

Indian Statistical Institute 203 B.T. Road, Kolkata – 700108