landing - eurosets · 2 ml/min 300 - 900 1 vo 2 ml/min 10 - 300 1 o 2er % 5 ... p in mmhg (kpa) 0 -...
TRANSCRIPT
CARDIOPULMONARY
DEFINING OPTIMAL PERFUSIONDURING CPB
LANDING
MAP Mean Arterial Pressure
D e f i n i n g o p t i m a l P e r f u s i o n d u r i n g C P B
TECHNICAL DATA ARTERIAL PROBESaO2 measurement method SpectrophotometricTemperature measurement Infrared sensor
Size (H x W x D) 45 x 80 x 28 mmWeight 50 g
Cable lenght 180 cmConnectors sizes 3/8”; 1/4”
TECHNICAL DATA VENOUS PROBESvO2 measurement method SpectrophotometricTemperature measurement Infrared sensor
Size (H x W x D) 45 x 80 x 28 mmWeight 50 g
Cable lenght 180 cmConnectors sizes 1/2”; 3/8”; 1/4”
CALCULATED PARAMETER UNIT RANGE RESOLUTIONDO2 ml/min 300 - 900 1
VO2 ml/min 10 - 300 1
O2ER % 5 - 50 1
SVR dyne*sec/cm5 600 - 2500 1
C.I. l/min/m2 0,5 - 3 1
DO2i ml/min/m2 100 - 500 1
VO2i ml/min/m2 10 - 150 1
O2ERi % 5 - 50 1
SVRi dyne*sec/cm5/m2 600 - 2500 1
dP mmHg (kPa) 0 - 800 1
B.S.A. m2 (ft2) 0,5 - 3,2 1
DATA MANAGEMENT SYSTEM
MEASURED PARAMETER UNIT RANGE RESOLUTION ACCURACYSaO2 % 90 - 100 1 ± 3%
SvO2 % 60 - 90 1 ± 3%
Q Blood l/min 0,5 - 8,0 0,1 ± 3%
Hb g/dl 5 - 16 0,1 ± 0,5 g/dl
Ta °C 4 - 42 °C 0,1 ± 0,5 °C %
Tv °C 4 - 42 °C 0,1 ± 0,5 °C %
P in mmHg (kPa) 0 - 800 1 ± 3% mmHg
P out mmHg (kPa) 0 - 800 1 ± 3% mmHg
MAP mmHg (kPa) 0 - 800 1 ± 3% mmHg
Taux °C 4 - 42 °C 0,1 ± 1 °C %
TECHNICAL DATA FLOW SENSOR EM-TEC Blood Flow measurement method Ultrasound
Size (H x W x D) 25 x 33 x 45 mmWeight 100 g
Cable lenght 280 cmConnectors sizes 3/8”; 1/4”
TECHNICAL DATA LANDINGDimension ( H x W x D) 220 x 290 x 85 mm
Weight (including holder) approx. 3,7 kgPower supply 100 - 243 VAC, 47/63 Hz
Battery runtime approx. 60 minDisplay module 10,4” TFT touchscreen
Resolution 800 x 600 pixelUpdate frequency arterial and venous every 5 sec
Interface1 serial RS-232 for in/out data
1 USB port for data export1 USB port for software update
BETTER PATIENT OUTCOMES
Distribuito daDistributed byDistribuè parVertriebDistribuido por
Prodotto daManufactured byFabriquè parHerstellerFabricado por
Eurosets s.r.l.Strada Statale 12, n°14341036 Medolla (MO) ItalyTel: +39 0535 660311Fax: +39 0535 51248E-mail: [email protected]
Rev. 09 / 2013
© Copyright 2013 by Eurosets S.r.l. - Catalogue, products, pictures may differentiate from the actual product appearance. Specifications are subject to change without prior notice.
AC
CE
SS
OR
IES
Ordering Guide
Code Description n./pack
EU5052 LANDING MONITOR FULL VERSION 01
EU1872 ARTERIAL PROBE 01 EU1873 VENOUS PROBE 01 EU1870 FLOW METER EM-TEC 3/8” 01 EU1869 POWER SUPPLYV 01 MX960P1 REUSABLE PRESSURE TRANSDUCER 03 MX260 HOLDER FOR REUSABLE PRESSURE TRANSDUCER 03 EU6593 CONNECTING CABLE MEDEX-LANDING 03 EU1517 TEMPERATURE PROBE YSI (for oxygenator and cardioplegia heat exchanger) 01EU10122 FLOW METER EM-TEC 1/4” 01
EU1589 SINGLE USE PRESSURE TRANSDUCER MEDEX, type MX960 10MX960P1 REUSABLE PRESSURE TRANSDUCER 01MX260 HOLDER FOR REUSABLE PRESSURE TRANSDUCER 01EU6593 CONNECTING CABLE MEDEX-LANDING 01
T100209A SINGLE USE EDWARDS PRESSURE TRANSDUCER 01DTH400 HOLDER PLATE REUSABLE 01DTSC HOLDER FOR REUSABLE PLATE 01EU6592 CONNECTING CABLE EDWARDS-LANDING 01
EU5053 BASIC LANDING MONITOR 01
EU1873 VENOUS PROBE 01 EU1869 POWER SUPPLY 01
EU3863 VENOUS CUVETTE 1/2” - 1/2” (3 boxes - 15 pcs/box) 45AG3863 VENOUS CUVETTE 1/2” - 1/2” COATED (3 boxes - 15 pcs/box) 45
EU3864 ARTERIAL AND VENOUS CUVETTE 3/8” - 3/8” (3 boxes - 15 pcs/box) 45AG3864 ARTERIAL AND VENOUS CUVETTE 3/8” - 3/8” COATED (3 boxes - 15 pcs/box) 45