last date of receiving tender date of opening the … · last date of receiving tender 2nd...

81
Tender –August 2016 Page No. : 1 COST OF TENDER FORM : Rs.1000/- WALCHAND COLLEGE OF ENGINEERING, SANGLI An Autonomous Institute TENDER DOCUMENT LAST DATE OF RECEIVING TENDER 2 nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2 nd September, 2016 at 3.30 pm In Conference Hall, Main Building

Upload: others

Post on 18-Apr-2020

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page No. : 1

COST OF TENDER FORM : Rs.1000/-

WALCHAND COLLEGE OF ENGINEERING,

SANGLI An Autonomous Institute

TENDER DOCUMENT

LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon

DATE OF OPENING THE TENDER

2nd September, 2016 at 3.30 pm

In Conference Hall, Main Building

Page 2: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page No. : 2

INVITATION FOR TENDERS UU

Ref No; - WCE/CS/ Date: - 18/8/2016 To ___________________________________ ___________________________________ Dear Sir, Sub: Invitation of Tender for supply of Equipments for Instruments, Computers, Furniture, Stationary etc. You are invited to submit your most competitive tender for supply of Equipments for various departments under the terms and conditions as enclosed herewith.

This tender form is also available on college website www.walchandsangli.ac.in While submitting the Tender, the offer must be submitted in following fashion. 1. Two separate envelopes are to be used. 2. First envelope should be titled as “Specifications Envelope” and it should contain documents such as: i) Shop Act license ii) I-Tax Return iii) Experience certificate iv) Sales Tax Registration v) Authorized dealer / distributor certificate vi)Proprietary item certificate , if applicable, viii) Copy of the receipt for Rs 1000/- for purchase of the tender form from the college office OR D.D. for Rs 1000/- if the tender form is down loaded from the college web site (for cost of tender form which is non refundable & without which tender will not be considered), viii) Separate (not a single) E.M.D. D.D.s for each of the department as per page number 81. All of the above D.D.s must be drawn from nationalized bank, favoring “The Director, Walchand College of Engineering, Sangli” payable at Sangli, ix) Detailed Specification of the offered item (if it differs from what is indicated in the tender) as per the tender form, but with no indication of offered cost of the respective item. Each Page must be signed and rubber stamped. This envelope must be sealed. At the time of tender opening, if the specifications and the other documents in this envelope are found correct, second envelope will be opened, otherwise the tender submission is likely to be rejected. The tender form is not transferable. Each bidder shall submit only one tender for one particulary department or section. 3. Second envelope should be titled as “Commercial Offer Envelope” and it must be sealed. Your “Commercial Offer” sealed envelope should contain competitive offered prices for the items. Taxes for VAT and other if any (except LBT) should be clearly indicated in the column “Total Amount”. LBT is to be paid at actual by the tenderer, while supplying items. The LBT receipt must be in the name of the Director, Walchand College of Engineering Sangli. Separate envelopes (and not a single envelope) are to be used for each of the departments. All the department specific pages of the tender form should be filled with the competitive prices offered, signed and rubber stamped on each page. The other specifications of the item, its make and model number, its detailed other features, leaflet of the items, customer list along with their contact details (where the tenderer has earlier supplied the item) etc., must be supplied in the department specific envelopes. If the space provided in the tender form is insufficient, additional pages may be attached appropriately. 4. Two of the separate sealed envelopes, namely, “Specification Envelope” and “Commercial Offer Envelope” must be sealed together in a “common” single envelope. 5. Each of these envelopes should be also titled, as per the case for either “Supply of Equipments for (Name of the resp. department)”. Tenderer must also mention their Company name, Address, email, contact person, cell no. etc. on envelopes. 6. If tenderer has SSI registration, the tenderer will be exempted from paying E.M.D. The valid SSI registration documents, for this purpose, must be enclosed in “Specifications Envelope”.

Page 3: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page No. : 3

7. If the tenderer is selected for supply of items, the selected tenderer will give an undertaking for supply of items as per the college’s terms and conditions, and the tenderer will supply the items accordingly. If the tenderer fails to supply the items as per college’s terms and conditions, the EMD amount of the tenderer will not be returned. EMD will be returned to all other “not selected” tenderers only when the selected tenderer supplies all the items as per college’s terms and conditions. The selected tenderer has to submit Bank guarantee for 10 % of total purchase value. The Bank Guarantee will be returned, if no violation of terms and conditions are found, only at the end of the warranty period or at the end of contract to the tenderer. The supply place is normally respective departments of college and supply period is usually 15 days from the date of placing order. We look forward to receive your tender and thank you for your interest in this system. Yours faithfully,

                                                                                                                       Director  Walchand College of engineering, Vishrambag, Sangli

Page 4: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 4 of 81

1. Civil Engineering Department:

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1 Dell New Inspiron 15 3558 15.6-inch Laptop/equivalent ,2.7GHz Intel 5th Gen, Core i5 processor,4GB DDR3L RAM,1TB hard drive,15.6-inch screen, 920M DDR3 Graphics,Windows 10 operating system,HD (720p) capable webcam, microphone

1

2 Peristatic Pump 2 microliter/min  to 2000 ml/min,0.25 HP with silicon wire  

1

3 Rotary  Evaporator    20‐280  rpm,  Dimensions  500mm  x 430mm x 410mm, Heat output 1300 W, RS 232 interface 1

4 Bacteriological incubator  100 L capacity, 0 to 50oC   

1

5 Sieve  Shaker   Measuring  range  20  µm  ‐  25 mm,  Sieving motion:  throwing  motion  with  angular  momentum, Amplitude: digital, 0.2  ‐ 3 mm, Time display: digital, 1  ‐ 99 min.,  Suitable  sieve  diameters:  100 mm  /  150 mm  /  200 mm / 203 mm   

1

6 Set of sieves ‐Brass  150 microns to 4.75 mm   

1

7 10KVA Online UPS:  Sukam/Microtek or equivalent make  ‐ online ups 10KVA with 20 No. of Batteries with  fabricated frame  for  battery  security  &  storage,Battery  Type  12V  ,Charging  Current  4A  ,(Expandable) Rated  Battery  Voltage  240VDC,  Adjustable  Input  Voltage 110  ~  276VAC,Adjustable  By  Pass  Voltage  110  ~  276VAC,Frequency  Range  45Hz  ~  55Hz  /  54Hz  ~  66Hz,Phase  Single  phase  with  ground,  OUTPUT  Voltage 200/208/220/230/240VAC,  Output  Waveform  Pure  Sine Wave ,Backup time 2 Hrs with full load of 50 no. of desktop 

1

Page 5: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 5 of 81

8 Epson L1800 A3 Size Color Printer/equivalent ,Printing Type: Colour Printing Technology: Inkjet Print Resolution: 5760x1440 DPI Paper Size: 4R, 5 R, A3, A3+, A4, A5, A6 Network: USB 2.0 Color: Black Paper Tray: 100 Sheets Warranty: 1 Year(s) Printer Type: Single Function 

1

9 Sony HDR‐PJ675 HD Video Recording Handycam Camcorder with Built‐in Projector with Standard Accessories(Carrying Case + Tripod etc.) /equivalent Model number HDR‐PJ675 Resolution 1920 x 1080 Included Components Rechargeable Battery, AC Adaptor, USB Cable, Micro HDMI Cable, AC Power Cord, User Manual Screen Size 3 Inches Optical Zoom 30 X Optical Sensor Resolution 9.2 Megapixels Video Capture Resolution 1280 x 720 

1

10 Desktop Corei7/4gbram/500Hard Disk/18.5”Led Screen/Key Board/Mouse/Atx Cabinet + SMPS or Intel® i7 Quad Core,1TB HDD,8 GB RAM,DVD RW Drive,20" Monitor ,USB Keyboard and mouse OR LENOVO Think Center 

8

11 Laptop‐  Dell Inspiron 15R‐5558 15.6‐Inch FHD Touch Screen Laptop/equivalent 2.20GHz 5th Gen Intel Core i5‐5200U Processor/12GB RAM/1TB HDD/Windows 8.1/1.5 GB Graphics  OR LENOVO Z510‐ i7/8gb ram/1tb hdd/4gb graphic/card reader/Bluetooth/Wi‐Fi/lan/HDMI/win8. 

1

12 Permeability  apparatus  as  per  IS  2720  (PTXVII)  constant and falling Head setup  

2

13 Overhead Tank Made of Steel for above Permeability test  2 14 Triaxial outfit Motorised with electronic sensors for38mm 

dia. Specimens as per IS 2720 (PTXIII)  Load Frame Motorised 50 KN capacity,  Triaxial Cell stationary bushing constant pressure system, Oil water type & elctronics  converation kit complete as above 

1

15 Proving Ring 500 KN capacity with dial guages and calibration 

1

16 Hydraulic Jack and Pump 50 Ton. Capacity  1 17 Sieves 20cm dia brass                            

 4.75mm‐2 Nos  600Micron 1 Nos  300 Micron 1 Nos  150 Micron 1 Nos  75 Micron 3 Nos 

Page 6: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 6 of 81

18 Shrinkage Limit set                                             Porcelein Evaporating Dish, Shrinkage Dish                          Perspex Plate with 3 metal prongs    spatula, Mercury 750gm, Straight Edge, Glass cylinder Graduated 25ml X 0.5 ml 

1

19 3D RAISED MODEL/MAP‐INDIA GEOLOGY  1 20 3D GEOGRAPHICAL/GEOLOGICAL PLASTIC RELIEF MODELS 

made of rigid PVC sheet with a markable & washable surface Size of each Model 100 x 75 cms supplied with hard backing aluminium frame & hanging hooks 

10

21 3D RAISED RELIEF PLASTIC MODEL/MAPS OF STATES (Maharashtra) 

1

22 Compression Testing Machine (automatic)‐Capacity 2000kN with least count of 0.1kN, Digital, Micro Processor Based, Servo Controlled, Automatic Pace Rate Control Piston Stroke 50mm, Min. Clearance Between Platens 370mm, Min. Distance Between Side Plates 340mm. •  Automatic stress determination and display. •  Overload safety protection. •  Self‐aligning platen with fast accessory change capability.•  Display of Peak Load,  •  Different modes for Compression, Flexure., Prism Testing, Tensile Splitting strength.  Password protection for system & calibration setup. •  2% overload facility to calibrate the machine upto ful capacity.•  Start, Stop, Pause & Reset. Brick Platens 220 V/230 V, single phase, 50 Hz, AC supply 

1

23 Accelerated Curing Tank  ‐Capacity  to accommodate 12‐18 Concrete Cubes of 150mm size, Boiling water method up to temperature range : 100 +/‐ 2 deg.C as per IS standard IS : 9013. Also  it will have  capacity  for  curing by warm water method at temperature 55 +/‐ 2 deg.C, rectangular double walled metal  cabinet,  inside  lined with  stainless  steel,  A slow  speed  stirrer,  lid  with  lifting  handle  to  cover  the chamber.DIGITAL  auto  tuning  PID  Temp.  Controller  with soak timer to control the duration of heating, 220 V, 50 Hz single phase, AC supply 

1

24 Digital Universal Penetrometer with Bitumen Penetration Kit (AIM 512‐1) 

1

25 Desiccator ‐  Vacuum Type, 250mm dia, polypropylene stopcock has a PTFE plug,  with Cartridge Desiccant 

2

26 Desiccator ‐ Vacuum Type, 300mm dia, polypropylene stopcock has a PTFE plug,  with Cartridge Desiccant 

1

Page 7: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 7 of 81

27 Vacuum Pump ‐ 115/230V, 50/60 Hz, single phase, 1/4hp, pressure gauge,  Max. Vacuum ‐25.5"Hg / ‐840mbar @60Hz / ‐24"Hg/‐810mbar @50Hz 

1

28 Degasification Apparatus‐ For deaeration of water 

1

29 Electronic Precision Balances ‐Maximum capacity 3.2kg, Readability 0.1g, TFT display, interfaces  USB Host / USB Device / RS232, fully automatic temperature‐controlled internal adjustment, Overload protection, Passcode protection, MinWeigh warning function 

1

30 Electronic Analytical Balances‐Maximum capacity 220gm, Readability 0.1 mg, TFT display, interfaces  USB Host / USB Device / RS232, fully automatic temperature‐controlled internal adjustment, Overload protection, Passcode protection, MinWeigh warning function 

1

31 Bottle type, Manually operated  Hyd.Jacks of 5T & 10 T    2 no each

32 Fabrication of  Loading Frame‐ Necessary fabrication work for strengthening the existing steel frame (having size‐1.00m*1.75m,I section‐100*200) to be used as a loading frame for block manufacturing and compression testing, inclusive of erection and concreting work, as per instruction by lab In‐charge. 

1

33 Total Station: Magnification / Resolving power‐ 30x / 2.5" Others Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect, Field of view: 1°30' (26m/1,000m),Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels Accuracy (ISO 17123‐3:2001): 5"  Measuring range: 0.3 to 500m(1.0 to 1,640ft.) Battery: Li‐ rechargeable battery 

1

34 Auto level :  32X Magnification, resolving power 3" , with tripod and two telescopic staves  minimum focusing distance 1.2.m 

2

35 Tilting Level  Magnification 24X , Normal accuracy 5mm/km, with tripod and two telescopic staves 

1

36 Repairs and Standardization of ‐ a) Experimental setup of Flow Measurement by  Venturimeter and Orifice meter b) Reynolds Experimental Setup  c) Bernoulli’s  Theorem Experimental Setup  d) Experimental Setup of Flow Measurement by  ‘V’‐ NotchNOTE : The rate should be quoted  by the contractor after physically visiting the equipment’s at the Hyd.lab in the civil engg  dept WCE sangli. 

Page 8: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 8 of 81

2. Mechanical Engineering Department:

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT + Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

1 Epson Class Room Projector EB-X31/equivalent (Qty-03): Resolution -XGA (1024X768), Brightness -3200 lumens, 3-in-1 USB, HDMI, Contrast Ratio-15000:1, Lamp Life-5000Hr (Normal), 10000Hr (Eco), Wireless –Optional, Projection System-RGB Liquid Crystal Shutter Projection system (3LCD), onsite service for projector or 1000 hours - whichever comes first with Ceiling Mount Kit and Wireless Dongle.Warranty-3Years on Site.

03

2 RENUTRON/equivalent Online UPS 6 KVA Capacity -10 KVA / 240 V DC, Pure Sine Wave, IGBT Based PWM Technology, Base-Dual Micro - controller Based with LCD Pannel, Isolation Transformer-Built in, Power Factor-IGBT based Input Power Factor Corrected Rectifier, Output Power Factor 0.8, Input Range Wider Input Range: 415 V +15% & - 20%, Phase -3 Phase Input 1 Phase Output, Charger-Heavy Duty Charger 15 Amp, Battery -AMARON. Warranty-3Years on Site.

01

3 3-Axis CNC Router

XYZ Guide T screw XYZ working area 210 x 190x 75 (mm) Drive type Stepper motor Spindle Mini Miller 400w, 30000rpm/min Feed Speed 1800mm/min (1500mm/min Recommend) Lead screws M10x1.5 pitch (mm) Repeat accuracy Better Than 0.04mm Interface NcStudio or Mach 3 Machine Size 385/380/390 mm (Length/Width/Height). Warranty-3Years on Site.

01

4 Commercial Water cooler with UV & RO Purifier Capacity: 80 LPH for Water cooler and purifier

3

5 *MAKIT – Master kit (Purely Mechanical components kit with precision manufactured links, joints, gears etc)

1

Page 9: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 9 of 81

6 MAKIT – HITECH (Electronic kit with built in programming controller kit with facility to simulate with the prototypes built out of MAKIT Master kit)

1

7 Pressure measurement using various instrument : bourdon gauge, diaphram gauge, bellow gauge etc. up to 15 Bar.

1

8 Displacement measurement using various instrument : Static and dynamic displacement measurement upto 20mm

1

9 Upgrading existing ANSYS software 25 users : 25 users perpetual

1

10 Data acquisition system trainer kit : 8 Channel data acquisition trainer kit compatible with USB port

1

11 Strain Gauge instrument : 1)static strain gauge with one, two and four arm type dynamic strain gauge with one, two and four arms type with minimum 5000 samples/ second

1

12 Small volume sample holder for Thermal conductivity analyzer (TCA): Small Volume Test Kit for testing as little as 3/8 tsp of powder or 1/4 tsp of liquid. Must be sold as an upgrade to either standard TCi System or Replacement sensor. Includes: spoon, spatula, weight, collar, test cell, SOP and all associated parts outlined in SOP.

1

13 Furnace for TCA to analyze thermal conductivity with respect to temperature (THERMAL CHAMBER): Temperature range: - 75 oC to +200 oC Interior Dimensions: 16" wide x 11" deep x 12" high Exterior Dimensions: 37" wide x 22-1/2" deep 30-5/8" high Voltage: 115V-120V 1 Phase 60Hz KW: 0.5kW Amp Draw: 18 Amps Type: Lunaire Test Chambers Air Flow

1

Page 10: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 10 of 81

14 Fiber Laser Machining Set-up Fiber laser machining set-up with rotary attachment as per following details Effective working area with or without Galva Mechanism = 100 *100 mm Laser Power = 50 – 60 W Laser Frequency = 40 – 100 KHz Work table = Table with up and down scan head Bed size – 300 * 300 mm Minimum character size – 0.20mm Maximum depth of cut in 10 passes – 0.5 – 1mm (for ferrous and non-ferrous metal) Cooling system – air / water cooled Maximum cutting/ marking speed – 6000 mm /s (for Mild steel) Computer system – industrial computer with WINDOWS Xp/ Win 7 / Win8 Data transfer – USB transmission With compatible software and graphic format supported

1

* MAKIT- MASTER CONTAINS SL NO. ITEM NAME CODE.No QUANTITY

1 BREAD - BOARD 001.1 2 nos 2 BREAD - BOARD 001.2 2 nos 3 BREAD - BOARD 001.4 1 nos 4 LEG 002 12 nos 5 LEVELLING SCREWS 003 12 nos 6 SIDE POST 004 6 nos 7 L - POST 005.1 6 nos 8 L - POST 005.2 8 nos 9 PIVOT 006 10 nos

10 BUSH BEARING 007 10 nos 11 SPACER 008.1 30 nos 12 SPACER 008.2 30 nos 13 SPACER 008.3 30 nos 14 SPACER 008.4 30 nos 15 LINK 009.03 8 nos 16 LINK 009.04 8 nos 17 LINK 009.05 8 nos 18 LINK 009.06 8 nos 19 LINK 009.07 8 nos

Page 11: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 11 of 81

20 LINK 009.08 8 nos 21 LINK 009.09 8 nos 22 LINK 009.10 8 nos 23 LINK 009.11 8 nos 24 LINK 009.12 8 nos 25 LINK 009.13 8 nos 26 LINK 009.14 8 nos 27 LINK 009.15 8 nos 28 DRIVE LINK 010.1 4 nos 29 DRIVE LINK 010.2 4 nos 30 DRIVE LINK 010.3 4 nos 31 DRIVE LINK 010.4 4 nos 32 SLIDER 011.1 4 nos 33 SLIDER 011.2 6 nos 34 SLIDER 011.3 6 nos 35 PIN 012.1 15 nos 36 PIN 012.2 15 nos 37 PIN 012.3 15 nos 38 PIN 012.4 15 nos 39 PIN 012.5 15 nos 40 PIN 012.6 15 nos 41 CIRCLIP 013 120 nos 42 STOPER BUSH 014 30 nos 43 PENCIL 015 1 nos 44 TRACING BOARD 016 1 nos 45 DRIVE HANDLE 017 1 nos 46 SHAFT 018.1 10 nos 47 SHAFT 018.2 8 nos 48 SHAFT 018.3 8 nos 49 SHAFT 018.4 6 nos 50 SHAFT 018.5 6 nos 51 SPUR GEAR 019.2 6 nos 52 SPUR GEAR 019.3 6 nos 53 SPUR GEAR 019.4 6 nos 54 SPUR GEAR 019.5 6 nos 55 SPUR GEAR 019.6 6 nos 56 SPUR GEAR 019.7 6 nos 57 SLEEVE COUPLING 020 20 nos 58 SMALL POST 021 6 nos 59 BOX 022 1 nos

Page 12: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 12 of 81

60 MOTOR WITH ADAPTER 023 1 nos 61 PULLEY 024 6 nos 62 ROPE 025 1 nos 63 GUIDE 026 6 nos 64 ANGLE 027.1 3 nos 65 ANGLE 027.2 3 nos 66 ANGLE 027.3 3 nos 67 ANGLE 027.4 3 nos 68 SPRINGS 028.T1 6 nos 69 SPRINGS 028.T2 6 nos 70 SPRINGS 028.T3 6 nos 71 SPRINGS 028.C1 6 nos 72 SPRINGS 028.C2 6 nos 73 SPRINGS 028.C3 6 nos 74 HINGER BASE 101 15 nos 75 SHAFT HINGER 102.1 6 nos 76 SHAFT HINGER 102.2 10 nos 77 SHAFT HINGER 102.3 10 nos 78 BEVEL GEARS 103.1 4 nos 79 BEVEL GEARS 103.2 4 nos 80 WORM & WHEEL 104 1 nos 81 U - JOINT 105 4 nos 82 DOUBLE U - JOINT 201 2 nos 83 SCREW ROD 202 4 nos 84 GENEVA MECHANISM 203 2 nos 85 NUT 204 4 nos 86 OLDHAN COUPLING 205 2 nos 87 RACK 206.1 2 nos 88 RACK 206.2 2 nos 89 CAM - HOLDER 207 10 nos 90 DISC CAM 208.1 4 nos 91 DISC CAM 208.2 4 nos 92 DISC CAM 208.3 4 nos 93 DISC CAM 208.4 4 nos 94 DISC CAM 208.5 4 nos 95 DRUM CAM OUTER 209.1 5 nos 96 DRUM CAM OUTER 209.2 5 nos 97 DRUM CAM OUTER 209.3 5 nos 98 DRUM CAM OUTER 209.4 5 nos

Page 13: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 13 of 81

Sl.No. Item.Name Code.No Quantity 99 DRUM CAM OUTER 209.5 5 nos 100 DRUM CAM INNER 210.1 5 nos 101 DRUM CAM INNER 210.2 5 nos 102 DRUM CAM INNER 210.3 5 nos 103 DRUM CAM INNER 210.4 5 nos 104 DRUM CAM INNER 210.5 5 nos 105 ROLLER 211 10 nos 106 ROLLER 212 10 nos 107 CROSS JOINT 213 10 nos

NEWLY ADDED COMPONENTS 108 15 DEGREE ANGLE LINK 3 NOS 109 30 DEGREE ANGLE LINK 3NOS 110 45 DEGREE ANGLE LINK 3NOS 111 60 DEGREE ANGLE LINK 3NOS 112 75 DEGREE ANGLE LINK 3NOS 113 90 DEGREE ANGLE LINK 3NOS 114 T DEGREE ANGLE LINK 3NOS 115 120 DEGREE ANGLE LINK 3NOS 116 135 DEGREE ANGLE LINK 3NOS 117 150 DEGREE ANGLE LINK 3NOS 118 90 DEGREE ANGLE LINK 3NOS 119 180 DEGREE ANGLE LINK 3NOS

Total number of components 944 NOS 944 nos

HARDWARE Sl.No. Item.Name Specs Code.No Quantity

1 CHEESE HEAD SCREWS M5 x 20 HO1 50 nos 2 CHEESE HEAD SCREWS M5 x 15 HO2 50 nos 3 CHEESE HEAD SCREWS M5 x 8 HO3 50 nos 4 HEXAGONAL NUT M5 HO4 100 nos 5 WING NUT M5 HO5 50 nos 6 WASHER M5 HO6 100 nos 7 CHEESE HEAD SCREWS M3 x 12 HO7 50 nos 8 CHEESE HEAD SCREWS M3 x 8 HO8 50 nos 9 CHEESE HEAD SCREWS M3 x 6 HO9 50 nos

Page 14: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 14 of 81

10 NUT M3 H10 50 nos 11 WASHER M3 H11 50 nos

TOTAL 650 nos

TOOLS SUPPLIED ALONG WITH THE KIT

1 SPANNER SET 2 NOS 2 NOSE PLAYER 1 NOS 3 SCREW DRIVERS 4 NOS 4 INSTRUCTION MANNUAL 1 NOS

Standard built in features supplied along with MAKIT-HITECH KIT

01. Inputs with Micro switches ------------------------------ 08 nos

02. Potential free outputs--------------------------------------- 08 nos

03. Dc Motors------------------------------------------------------02nos

04. Stepper Motors------------------------------------ ----------- 02 nos

05. Built in counters---------------------------------------------- 24 nos

06. Built in Timers------------------------------------------------- 24 nos

07. Built in Memory Flags---------------------------------------- 24 nos

All with user friendly MAKIT – HITECH S P M software. (Compatible with windows xp with service pack 2 ) *

Page 15: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 15 of 81

3. Electrical Engineering Department

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT + Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

1 Slip Power recovery scheme for 3-Ph, 440 volt, 3 H P, 50 Hz Induction Motor with suitable eddy current loading arrangement. The setup consists of 3-Ph diode bridge and line commutated Inverter, Associated firing angle control circuits AC, DC voltmeter and ammeter & wattmeter

01

2 Supplying, installation & Commissioning on old foundation with C channel. The machine  specification are as follows  Single Phase Induction Motor: 

Capacitor Start # Brake Drum: 230V, 1420 RPM, 50 Hz, 2 HP, 6 A 

Universal Motor # Brake Drum: 230V, 1420 RPM, 50 Hz, 2 HP, 6A.  The above machines are individually coupled to brake drum equipped with spring balances.

01set

3 dSPACE ACE kit 1104 and CLP1104: dSPACE ACE kit 1104 – software Implementation software = RTI, MLIB/MTRACE, Experimental Software-control Desk developer version CCPPPC- Microtec C complier for Motorola power PC dSPACE ACE kit 1104 –Hardware Processor power PC type= PPC803e, CPU clock=250 MHz, Cache=2x16 KB memory, SDRAM=-32 MB, SDRAM flash=8MB, 4 general purpose timers, 32 bit down counter, 80 nanosecond resolution AD converter, 4 multiplexed 16 bit,2 microsecond, 4 parallel, 12 bit 800 nanosecond 10 volt or higher D/A converter, 8 channel,16 bit,+-10 V, D/A converter 8 channel 16 bit +- 10V, 10 micro second or higher, SLAVE DSP TMS320F240, 20 MHz CLP1104-connector/ LED combi panels for DS1104 Connector panel provides easy access to all input and output signals on the controller board, analog signals via BNC connector, digital signals on SUB D connector. Connector/ LED combi panel contains additional LED panels to indicate the current level of digital signal.

01

Page 16: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 16 of 81

4 Digital multi meter: 31/2 digit LCD display with facility to measure following parameters. Resistance DC voltage AC voltage DC current AC current Diode test function Continuity test function

01

5 Upgrading MiPower 8.0 power system analysis software to latest version MiPower 9.1 or above, with 5 days L2 level training for two persons at PRDC Bangalore. Annual software support for new version of MiPower from date of contract signing, providing updated user manuals in softcopy, providing technical support

01

6 STATIC VAR – THYRISTOR CONTROLLED SERIES COMPENSATION TRAINER/KIT

It shall consists of 1. Generating Station Module 2. Thyristor-controlled series compensator

(TCSC- a typical series FACTS controller) composed of a series capacitance which shall have a parallel branch including a thyristor-controlled reactor. TCSC shall provide reactive power compensation for varying the reactance of the transmission line. TCSC shall operate in different modes depending on when the thyrsitor for the inductive branch are triggered. The modes of operation that shall be a. Blocking mode: Thyristor valve is

always off, opening inductive branch, and effectively causing the TCSC to operate as FSC

b. Bypass mode: Thyristor valve is always on, causing TCSC to operate as capacitor and inductor in parallel, reducing current through TCSC

c. Capacitive boost mode: Forward voltage thyristor valve is triggered slightly before capacitor voltage crosses zero to allow current to flow through inductive branch, adding to

01

Page 17: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 17 of 81

capacitive current. 3. TCSC shall provide 75% capacitive

compensation of the total 3 phase line reactance.

4. SCR power circuit components to meet the above requirements.

5. Inbuilt controller board for controlling the firing angle 0-90° or 90-180° as per the reference of voltage waveform shall be taken.

6. 3-ph Artificial Transmission Line of 180 Km long. The line shall have six pi section of 30km each so that different types of fault at every 30km length can be created by fault breakers.

7. Three phase fault breaker/creater to create different types of fault e.g. LG, LL, LLG, LLL, LLLG at step of 30 km in total line length of 180km (i.e. 6 pi line sections).

8. RLC Load setup (Distributed Load System): – 3 Nos.variable Resistive Load 0-250Wwith Selector Switch 2 Nos. Inductive Load 1 HP 3Ф Induction Motor with Mechanical Load.

9. 2 Nos. of Digital multifunction meters shall be provided to measure various electrical Parameters of transmission line

10. 4 Pole miniature circuit breaker and fuses for protection. Pilot lamp indications to represent healthy source

11. External connector terminals for performing external experimental Connection.

12. Interface cards to export the measured electrical parameters of transmission line to PC.

13. A detailed manual shall be provided which describes the connection of experimental Procedures.

14. FC-TCR module with necessary control equipment and measurement unit shall be provided to act as load end compensator. This unit shall give a smooth variation of Reactive Power compensation to improve the voltage profile.

Page 18: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 18 of 81

7 Laptop : Intel Core I3 6th generation processor/equivalent, 2.3 GHz Processor, Windows 10, 8GB RAM DDR3L 1600MHz, Harddisk 1TB 5400rpm SATA Harddrive, 15.6 inch HD LED display, Graphics Card AMD Radeon R5 2GB DDR3, Wifi IEEE 802.11b/g/n, CD/DVD writer

4

8 DSP Kit : ezdsp™ F28335 board (w/out socket) with Code Composer Studio DSK tools and power supply with XDS510USB JTAG Emulator and Code Composer Studio for C2000 supporting windows 8

2

9 Three phase Hall Effect Voltage and Current Sensors Hall effect current sensor Input to Current Sensor: 0-30A rms , Output of curentSensor = 0-5volts Hall effect voltage sensor Input to voltage Sensor 0-440volts, Output of voltage sensor=0-5volts

2

10 Tektrronix make 70 MHz, 2 Ch, 1GS/s, TFT Digital Storage Oscilloscope: TBS1000B Series Features: Key Performance Specification: 70 MHz Bandwidth models, 2-Channel Models, 1GS/s sample rate on all channels, 2.5k point record length on all channels, Advanced triggers including pulse and line selectable video triggers, Key Features: 7 inch WVGA (800X480) Active TFT color Display, 34 automated measurements, Dual window FFT, simultaneously monitors both the time and frequency domains, Built-in waveform limit and Dual channel frequency counter, Zoom Function, Automated, extended data logging feature, Auto set and auto ranging functions, USB 2.0 host port on the front panel for quick and easy data storage, USB 2.0 device port on rear panel for easy connection to a PC, Standard Accessories: Passive probes, one per channel: TPP0051: 50MHz passive probe for TBS1052B, TPP0101: 100 MHz passive probe for: TBS1072B, TB1102B, TPP0201: 200 MHz passive probe for: TBS1152B, TBS1202B, Power cord (Please specify plug option), NIM/NIST Traceable certificate of calibration, printed documentation Installation and safety manual, CD with customer documentation-customer documentation including detailed user manuals

04

11 Dual Power supply : 0-30 V, 5A, Variable with Short circuit and current limiting protection

04

12 Function Generators : Sine, Cosine, Triangular, Square wave generation with variable frequency (10 Hz-10MHz, 0 to 30 Volts PP)

02

13 Desktop: OptiPlex 24 7000 Series All-in-One (7440) Desktop/equivalent:

02

Page 19: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 19 of 81

Technical specifications – • Intel® 6th generation Core™ i7 processor, Chipset

Intel Q170, Windows 8.1 Pro 64-bit operating system, Up to 2 DIMM slots Non-ECC dual-channel 2133 MHz DDR4 SDRAM Supporting up to 16GB, Integrated Intel® HD Graphics 530, 1 TB HDD (7200rpm), With a 60.5cm (23.8) screen with Full HD or 4K Ultra HD, External USB 3.0 – 6 (2 side, 4 rear) USB 2.0 – 2 (rear) HDMI 1.4 In/Out – 1 (Full HD Only) DisplayPort 1.2 – 1 RJ-45 – 1 Universal Headset (side) – 1 Line-out – 1 (rear), Keyboard Dell Wired Keyboard with Multimedia functionality, Limited Hardware Warranty Standard 3-year On Site Service after Remote Diagnosis (3-3-3)

14 Power factor meter : 0.1 to 1 – lead + lag arrangement ( Digital )

02

15 Power factor meter : 0.1 to 1 – lead + lag arrangement (Analog)

02

16 Frequency meter : 0-90 cs/s ( Digital ) 02 17 Frequency meter : 0-90 cs/s ( Analog ) 02 18 Phase Shift Transformer : 0 to 1800 01 19 R-L-C resonance Model variable resistance ( 1K

ohm-2 to 10K ohm) variable capacitance ( 0.1 to 100 micro farad variable inductance 0.1 mega henri to 100 mega henry

01

20 LCR meter: R = 1 milli to 100 k ohms, C = 1 micro farad to 10000 micro farad and L = 1 milli h. To 100 milli henry OR Digital LCR meter: 3 ½ Digit LCD display with indication of polarity, over range, & Low battery. Resistance measurement range: 20ohm to 20 mega ohm Inductance measurement range: 200 micro H to 200 H Capacitance measurement range: 200 pF to 2000MFD (Accuracy better than +/- 6% for L & C and better than 3% for R on all ranges) Diode Test functions.

01

21 DC variable power supply : 0-30 volts- 10 Amps 05 22 Variable R ( Resistance ) boxes = 0 – 100 milli ohms 04 23 Variable reactance boxes = 0 – 100 milli henry 04 24 Variable Capacitance Boxes = 0 – 100 micro farad 04 25 Kelvin double bridge : 1 milli ohms to 100 ohm

resistance measurements & prescience galvanometer , rated current 10 A DC & rated voltage 0-30V DC, accuracy 0.00001 ohm ± 0.2 %, 10 steps of 0.001 ohms

02

26 Murrays loop test Kit 02

Page 20: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 20 of 81

27 Trivector meter : 110 volts, 20/5 Amps, C.T. operated digital, accuracy ± 5 %, measured value KWH, Kvarh, Kvah

01

28 3-Ph, ½ HP induction motor VFD drive, suitable for 1-Ph, 230V Supply frequency variation : 5 Hz to 50 Hz, Induction motor rated 230V, 3-Ph, 50 Hz , 1/2 HP induction

01

29 Wheaston Bridge : 0.1 to 1 mega ohm, 230V AC and 0.5 V DC

01

30 DC Potentiometer : variable resistance box 0.1 ohm to 10000 ohm

01

31 Liquid Flow-Ultra Sonic : Parametric Fluid velocity 0 to12 m/sec +/-0.5%

01

32 Air Flow : Telescopic Vane type anemometer Air Flow- m/sec 0.4 to 40m/sec +/-(0.2m/s + 2% of mv)

01

33 Pitot Tube (L Types) : Velocity Pressure 01 34 Temperature : Thermal Imaging Camera : -20

to100°C/0-280°C +/-2°Cor+/-2%of reading (whichever is greater)

01

35 Thermocouple (K Type) : Temperature in °C -14 to 400°C

01

36 Thermocouple (K Type) : Temperature in °C -200 to1000°C

01

37 4-Channel temperature data logger Temperature in °C -20°C to130°C

01

38 Humidity : Thermo hygro meter with data logging Temperature & RH 0-100% RH, +/-2.5% of RH&+/-0.5°C

01

39 Pressure meter : Air Pressure 0 to100 hPa +/-0.03 hPa (0 to30 hPa)

01

40 Bourdon Type Dial Pressure gauges: Liquid, 10 & 40 kg/cm2

01

41 Lux Meter : Illumination level 0 to 99,999 Lux, +/-3%

01

42 Printer: All in one (Scan with printer and copy) HP make Printer (Model No. HP 1005) /equivalent details specification 14 ppm (ISO) –A4 print & copy, 150-sheet input tray+ 10- sheet priority feed, 1200x1200 dpi print resolution, manual duplex & Booklet printing, watermarks, Economode,230 MHz with 32 MB Ram

02

Page 21: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 21 of 81

Under Electrical Maintenance 43

14 SWG CRCA sheets using erecting of 4way or 6 way LT feeder panel (Feeder pole )with aluminium busbar including following switchgear. Incoming : 100A TP MCCB-1 No, 0-200A ammeter-1 No, ammeter selector switch - 1 No, 200/5A current transformer -3 No, 0-500V voltmeter - 1 No, Voltmeter selector switch- 1 No, RYB indicating lamp -3 No, control fuse- 3 No and neutral link - 1 No, Outgoing : 63A TP MCCB - 5 Nos, Outgoing 63A + 3-Ph plug socket - Nos, Plug socket - 1 Nos. Panel should be installed as feeder pole given ISI

04

44 Cable Jointing at minimum two points, cable having (70 Sqmm 3.5 core aluminum cable) cable joint must be given in ISI and as per proper standard.

02

45 Inspection and maintenance of 11 KV H.T. substation (flow pole mounted 3-ph, 125 KVA, two transformer) in WCE campus, In necessary change the following parts: Provision of AB Switch 1 set Provision of lighting Arrester Qty: 3 No, oil level indicator :2 No, Silica gel breather: 2 Nos and supply of transformer oil. In the maintenance for structure, painting, concerting (if required) and any other work should be carried out as per ISI standard.

01 set

46 AC & DC Distribution panel for Electrical machine lab for following switchgear specification:

• 14 SWG CRCA sheets panel and busbar should be copper

• HRC Fuse : 100A : 3 Nos • MCCB : 4 pole, 100A : 01 No • MCCB: 4 pole 63A: 06 Nos. • MCCB 2 Pole DC Supply 63A : 02 Nos • R,Y,B, 400V, AC Supply and DC supply

indicator lamps: 04 Nos • 100A Ammeter with 100A/5A CT and

Ammeter selector switch: 01 Nos • 0-500 voltmeter with selector switch : 01 Nos • 0-50A DC Ammeter : 01 Nos • 0-300V DC voltmeter : 01 Nos

Note : Refer single line diagram of panel provided with tender

02 Panel

Page 22: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 22 of 81

3A. Electrical Engineering Department

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT + Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

1 200 kVA DG set (brief details below) 01

200 kVA DG set for W.C.E. Sangli TECHNICAL SPECIFICATIONS FOR DG SET

PREAMBLE:

The scope of work includes supply & installation of lx 200 KVA DG set mounted inside acoustic enclosure and associated works. The outgoing cables are through trench.

1.0 GENERAL

1.0 This specification covers the turnkey installation of 1 X 200 KVA standby AMF diesel generating system covering the diesel engine, alternator, engine control panel, associated accessories, cooling system, ventilation system, fuel and exhaust system, acoustic endosure and switchgear etc.

The contractor shall assume full responsibility of co-ordinating the work with various sub-vendors and other contracting agencies at site and execute the work to the total satisfaction of the clients and statutory agencies.

2.0 SITE CONDITIONS:

Temperature Maximum : 45 deg. C

Minimum : 20 deg C

Humidity : 100% during monsoon.

Rainfall : approximate 500 mm per annum.

Altitude : MSL.

3.0 ELECTRICAL SUPPLY SPECIFICATIONS :

Nominal voltage : 415V ± 5%

No. of Phases : 3 + Neutral (R,Y,B,N)

Frequency : 50 Hz ± 3%

Neutral earthing : Solidly Grounded.

Control supply : 24V, 2-wire DC.

Page 23: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 23 of 81

4.0 SCOPE OF WORK & EXCLUSIONS:

4.1 The scope of work shall include but not be limited to the supply, installation, testing and commissioning of the following items. The supplier shall study the requirements stipulated in the specification and also to suit the site conditions and offer a complete system with guaranteed performance under the severest operating conditions specified.

a.1 No. 415V, 3-phase + Neutral, 200 KVA 1500 RPM, DG set with accessories as specified.

b. Set mounted microprocessor based engine control panel

c. Radiator cooling system.

d. Exhaust piping including supports.

e. Thermal insulation for exhaust piping.

f. Exhaust stacks with steel supporting system for the two sets.

g. Fuel piping.

h. Integral Acoustic enclosure (canopy).

i. Switchgear panel as specified

j. Obtaining approval of the installation from pollution control board and all other statutory authorities.

k. Preparation of related schematic and GA drawings for DG installation, exhaust piping, fuel piping, ventilation system, acoustic enclosure, etc.

I. Co-ordination with other agencies to ensure timely completion.

m. Obtaining Diesel Engine manufacturer's approval of the installation with specific emphasis on alignment, exhaust & fuel piping and ventilation before commissioning.

n. Testing and commissioning of the installation.

o. House keeping during the installation work and removal of debris & unwanted materials on day to day basis and clearing the site on completion.

p. Any related work covering supply of installation materials, consumables, etc. whether specified or not, to render the system fully functional and conforming to the best engineering standards. This shall include battery charging.

q. The tenderer shall arrange for all civil construction works for making foundation for DG sets, diesel tan, making trench in panel room. The design of the foundation shall be approved by Dean planning/Civil works of WCE Sangli.

Page 24: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 24 of 81

5.0 DIESEL ENGINE & ACCESSORIES:

5.1 ENGINE

a. The diesel engines shall be of approved make, direct injection, four stroke, multi cylinder (six), water cooled, radiator type, turbo charged, operating at a nominal speed of 1500 R.P.M and capable of developing requisite BHP.

b. The engine and the governing system shall be suitable for standby and AMF duty power generating application and shall conform to BS: 5514 / ISO 3046. The unit shall be suitable for operation on high speed diesel oil available in Indian Market.

c. The engine shall be electric start and shall be suitable for battery assisted manual/ auto starting.

d. The governing system of the engine shall be electronic type and suitable to control frequency variation within ± 3% whenever a load of 200 KVA is switched in or thrown off.

e. The engine fitments shall include but not be limited to the following.

i) Flexible coupling and flywheel with guard.

ii) Dry type air filter with clogged condition indicator.

iii) Cooling radiator.

iv) Fuel pump.

v) Step timing control inject with Electronic governor.

vi) Dual fuel filter with on line filter changing provision.

vii) Lube oil pump, oil cooler and filter.

viii)Turbo charger.

ix) 24V DC starter & battery charging alternator.

x) Engine mounted microprocessor based control panel to display the following engine and electrical parameters:

a. Lube oil pressure indicator and temperature gauge.

b. Tacho meter for speed indication with hour meter.

c. Battery charging Ammeter.

d. Starting switch with key.

e. Over speed stop switch with contacts.

Page 25: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 25 of 81

f. Low lube oil pressure switch.

g. High water temperature alarm & trip

xi) Wiring harness using temperature resistant insulation and flexible copper conductor wires. The wiring should be damped at egular intervals and terminated using lugs and terminals.

xii) Stainless steel flexible for engine exhaust.

xiii) Stop solenoid.

xiv) Control cables from Engine to AMF panel using 12 core,4 core copper armored and 3 core 2.5 sq.mm screened cables.

f. The engine speed shall be regulated through an electronic governing system which shall also provide the over speed protection. The governor shall ensure that the speed of the set is regulated within 1% of the nominal speed under normal operating conditions.

h. The DG set shall be capable of handling step load upto 80% of the capacity without dropping other loads due to voltage dips. Further the engine shall be capable of taking full load within 10 seconds of starting.

i. All moving parts of the engine and other associated equipment shall be provided with guards to prevent accidental contact. The guard shall be designed to facilitate easy removal and reinstallation.

j. The engine supplied with first filling of oil of required quantity as recommended by the manufacturers.

5.2 ACCESSORIES

The following accessories shall be supplied with the DG set.

a. Common base frame for the engine and alternator.

b. Antivibration mounts of requisite capacity (Dunlop series S make)

c. Residential Silencer.

d. Protective guards for all rotating parts.

e. Electric driven lube oil priming pump complete with hosepipes and couplers.

f. Diesel tank of 500 Ltrs. Capacity fabricated out of 6mm thick sheet steel including first filling of diesel.

The tank shall be further complete with overflow pipe, drain pipe, fuel level indicator, valves, manhole with cover, low level contact & alarm.

g. 16 SWG galvanised sheet steel trays beneath the engine and day tank to collect the leakage oil.

Page 26: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 26 of 81

h. Batteries

The batteries shall be of heavy duty, high performance lead acid type of Exide make. Each battery shall be rated 12V. The number and AH capacity shall be selected to suit the engine requirements.

Battery shall be suitable for six successive starting attempts each of 10 seconds duration with a gap of 5 seconds between successive starts.

The battery shall be supplied complete with electrolyte and accessories. The accessories shall include battery stand, battery leads with terminal ends acrylic top cover and inter battery connectors.

Each battery is provided with a charger to charge the batteries when the set is not running. The charger shall get disconnected while the generator set is running automatic.

i. Control Panel :

Each set shall be supplied with an engine mounted Microprocessor based control panel. The control panel shall display all the engine, alternator & battery parameters. It shall not only display faults but also keep a record of faults. An emergency stop push button will be provided to stop the DG during emergency. For Engine faults, the set will be stopped in emergency mode & for electrical faults it shall be stopped with a time delay for cooling down. An audible alarm shall be provided in the main panel to announce tripping of DG's. The panel shall have output port for monitoring.

J. Alarms

The following alarms shall be provided in the DG control Panel to indicate & protect against abnormal operations.

Condition Status Function

Low Oil Pressure 2 stage Alarm Engine Stop

High Water Temperature 2 stage Alarm Engine Sop

Over Speed Alarm Engine Stop

Low Fuel Level. Diesel Alarm

High Fuel Level. Diesel Alarm

Earth fault on Alternator Alarm Engine Stop

Fail to start Alarm

Battery charger fault Alarm

Page 27: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 27 of 81

k. Automatic Mains Failure :

On receiving signal from voltage monitor relay ( shall be supplied by the DG vendor to the panel builder) provided in the EB incomer panel for low voltage,power failure or phase failure, the set shall start & on developing the voltage the respective DG breaker shall close & start feeding loads. On resumption of EB power the voltage monitor will monitor the voltage for a preset time ( 3-10 min ) & then trip the DG breakers & subsequently close the EB breaker. Necessary control wiring between the DG Control Panel & the DG breakers in the DG panel shall be in the scope of work of the DG vendor.

6.0 ALTERNATOR

1500 RPM, 415V, 3-Phase, 200 KVA, star connected, 50 Hz, 0.8 P.F (lag), 50Hz, 3 phase, 4 wire system conforming to BS 5000 / IS 4722. The alternator shall be horizontal foot mounted, single bearing, self excited, self-regulated, brushless, screen protected drip proof, continuous duty alternator with class "H" insulation in IP-23 enclosure incorporating the following.

a. Continuous damper winding.

b. 6 Nos. RTDs and one anti condensation heaters wired to a separate terminal box.

c. Pilot exciter.

d. 3 Phase sensing AVR with ± 0.5% voltage regulation.

e. A neutral CT of adequate ratio and class for REF relay for DG Protection..

f. Separately mounted adapter box suitable for cable termination of size 2R x 3.5C x 300Sqmm armoured Aluminium XLPE cable between alternator terminals and adapter box.

6.1 The alternator shall further meet the following specifications.

a. The alternator shall conform to IS 4722 / BS 5000.

b. The alternator shall be suitable for 20% over speed for two minutes.

c. The alternator shall be capable of carrying 50% overload for a duration of one minute.

d. The alternator shall be capable of carrying 10% overloading for one hour in any period of 12 hrs running.

e. The inertia constant shall be 0.26 second or above.

f. The alternator terminal voltage for any load variation should be maintained within ± 5%..

g. The prime mover response should be such that with 200KW load throw OFF 1 ON for the generator both transient and steady state frequency variation should be within ± 3%. The generator terminal voltage for this load variation should be maintained with ± 5%.

Page 28: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 28 of 81

h. The field coil terminals shall be wired to terminal box for external speed control.

i. Both ends of each phase winding shall be brought to the terminal box.

j. The alternator shall withstand a 3-phase short circuit at the terminals for a period of 3 seconds.

k. The total harmonic distortion shall n of exceed 3% and the design shall permit upto 30% unbalance between phases while in operation.

7.3 Performance:

With the integral acoustic enclosure, the sound pressure levels when measured at a distance of 1 mtr outside the DG enclosure louvers shall be not more than 70 dB/ aspiration as per MCPB, CPCB under free field conditions.

7.4. Painting:

The entire system shall be coated with Red oxide paint.

After erection rust preventive painting must be essential.

After erection one coat of Grey color synthetic enamel or color is left to the choice of the WCE Sangli.

7.5 Dimensions:

The overall dimensions of the enclosure shall be such as to provide free movement all round the DG set inside the enclosure. Two sliding doors of adequate size shall be provided on either side of the DG Set to facilitate easy inspection and carry out maintenance works.

8.0 PIPING & ACCESSORIES:

a. The piping shall be of Class 'B" M.S pipe of 80mm dia.

b. All accessories such as strainer, isolating valves, non-return valves etc. shall be supplied as required based on approved piping layout d rawings.

c. The piping schematic shall be submitted wi from engine & drain pipes. h the bid. Which should include supply, over flow return

d. The piping shall be painted with one coat color. of primer and two coats of finishing paint of approved

e. One number manual gear pump for filling the diesel tank shall be supplied per DG.

Page 29: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 29 of 81

9.0 Spares :

The DG set will be supplied with the following spares, which shall be handed over at the time of commissioning.

2 sets of renewable parts of oil, fuel & air filters.

2 Nos. fan belts.

5 Nos. spare fuses of each type & size used.

2 spare relays of each type.

sets of fuel injectors.

1 No. Manual gear pump

11.0 INSTALLATION:

The bidder shall undertake the installation work at site. The general scope of installation work shall include but not be limited to the following.

11.1 DIESEL GENERATOR SET:

a. The assembled Diesel Generator set shall be installed in the container on anti-vibration mounts. The unit shall be visually inspected for any transit damage.

b. The contractor shall arrange for the inspection of the set by the diesel engine manufacturers authorized representative and obtain his approval before rolling the set.

c. The fuel oil day tank shall be installed over the drip tray at the location indicated.

d. The batteries shall be fully charged, installed and connected.

e. The battery charger shall be heavy duty.

11.2 FUEL PIPING:

a. The fuel piping shall include supply and installation of Class "B" MS pipes of adequate size with necessary valves and accessories required for the supply & return lines from day tank to the engines. The pipes shall be painted with primer over which 2 coats approved colour paint shall be applied.

b. The joints in the line shall be properly sealed to avoid any leakage of fuel.

11.3 EXHAUST PIPING

a. The exhaust piping shall be fabricated from 6mm thick MS pipes.

b. The exhaust piping and the silencers shall be insulated using 50mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded with 24G aluminum sheet.

c. The exhaust pipe shall be supported using spring suspension supports.

Page 30: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 30 of 81

d. The shipping sections of the stack shall be welded at site and erected over the MS frame work. The entire length including the flanges, bolts and washers shall be aluminised inside and outside to inhibit corrosion. A weather cowl shall be provided on top.

e. All tools and tackles used for the erection shall have valid safety certification.

11.4 ELECTRICAL INSTALLATION:

a. The electrical power cabling from alternator to the panel will be carried out by other agencies. However the DG control cabling from the DG to the DG Panel will be carried out by the DG vendor.

b. The contractor shall appoint an experienced full time engineer throughout the installation period till the set is handed over. One month maintenance from the date of commissioning shall be carried out by the DG vender.

c. The contractor shall carry out the control cabling from the engine control panel to the breakers in the main panel.

d. Connecting block with wiring diagram shall be provided in the DG Panel for integrating with the EB Panel.

12.0 TESTING:

12.1 AT MANUFACTURER'S WORKS

The routine tests and full load test on Engine, Alternator shall be carried out at manufacturer's work in accordance with applicable Indian standards in the presence of Industrial expert.

12.2 TESTING AT '0EA's WORKS

Following tests shall be conducted at the assembler's work in the presence of client's representatives.

a. Full load testing for 8 hours with load bank (minimum 80 to 85 % efficiency).

b. Overload testing at 10% overload for one hour immediately after the full load test.

c. Operation of protective devices.

d. Noise level and vibration test should be within tolerance limit of ISI.

Page 31: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 31 of 81

12.3 SITE TESTING:

Following tests shall be conducted at site in the presence of the client's representative before energisation. The contractor shall provide all testing equipment, labour and consumables required for the testing.

a. Checking the alignment by engine manufacturer's representative and obtaining approval.

b. Insulation resistance test on alternator, control panel and cabling / Bus bar trunking.

c. Checking the AMF operation both on auto and manual mode.

d. Checking the engine safeties for satisfactory operation.

e. Checking vibration levels.

f. Testing of individual protective devices on engine and alternator and ensuring that the wiring is carried out properly.

g. Full load running for 8 hours continuously. All the readings shall be logged to evaluate the fuel consumption, lube oil pressure, water & oil temperature vis-à-vis the electrical load.

h. One hour overload testing at 110% load shall be carried out at the end of the full load trial.

i. The guaranteed specific fuel consumption shall not exceed 150 grams / BHP. HR with a tolerance of + 2.5 %. The same shall be proved during the load trial.

j. The noise level at 1m from the enclosure and the temperature rise inside the enclosure shall be measured.

k. Any deviation from the guaranteed parameters shall be made good and these performance parameters should be measured once again till the required results are achieved.

I. The DG set shall be deemed to be commissioned after satisfactory performance of all associated equipment.

13.0 TAKING OVER

The clients will take over the DG set for operation on completion of the following.

a. DG set are installed, tested and commissioned as per the specifications.

b. Original test certificates are furnished for engine, alternator, acoustic enclosure, centrifuge and all other bought out items.

c. Load trials are successfully conducted including the performance of acoustic enclosure and ventilation fans.

d. Approvals are obtained from Pollution Control Board and Electrical Inspectorate.

Page 32: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 32 of 81

e. 4 sets of AS BUILT documentation. spare parts list, maintenance chart and operation and maintenance manual are to be submitted.

f. The set shall be handed over with first fill of lubeoil and day tank along with spares mentioned.

14.0 GUARANTEE

14.1 DG SET

The DG set and accessories shall be guaranteed for satisfactory operation for a period of 24 months from the date of commissioning or 5000 running hours from the date of supply whichever is earlier. Any defects noticed during this period shall be rectified free of cost.

The supplier shall indicate the type of records to be maintained so that the warranty claims if any are honoured by the manufacturer.

The design and installation of acoustic treatment shall ensure that the noise level at lm from the DG Room at any point shall not exceed 70dBA while operating the set at rated load.

15.0 MAINTENANCE

15.1 The bidder shall be required to maintain the installation at no extra cost to the owner for a period of two year from the date of commissioning. During this period, the contractor shall make good any defects caused due to faulty design, bad workmanship and poor quality of materials.

15.2 The response time for any break down call shall not be more than 2 hours.

15.3 During the guarantee period, the bidder shall carry out regular servicing of the unit at regular interval as recommended by the manufacturer. The consumables required for this will be made available by the clients.

16.0 DOCUMENTATION

As a part of the equipment supply, following documentation shall be furnished.

a. General arrangement plan of DG set.

b. Piping schematic diagram

c. Chimney fabrication drawing.

d. Layout of fuel and exhaust piping.

e. Layout and constructional details of acoustic treatment.

f. Calculations for ventilation system design.

g. Engine wiring diagram.

h. Test certificate for engine and alternator.

Page 33: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 33 of 81

i. Installation, operation and maintenance instructions for diesel engine, alternator.

j. Spare parts list.

k. Approval from Pollution Control Board and Central Electrical Inspector.

l. Manufacturing certificate inclusive date and time for Alternator1 and diesel engine set.

17.0 PREFERED MAKES

(In case the tenderer proposes to supply any make other than in the approved list. Then the tenderer should submit,

1. Full technical specifications,

2. The proposed model should have been installed in at least 3 locations not less than 200 kVA each. Completion certificate and performance certificate should be submitted in the technical bid. It may be noted that this criteria in addition o the eligibility criteria mentioned in the tender notice and is required only if new make of Engine and alternator is proposed)

17.1 Diesel engine with residential silencer. : Caterpillar / Cummins / Perkins /MTU/equivalent

17.2 Alternator : Stamford / Leroysomer/equivalent

17.3 Antivibration mounts : Dunlop - S class

17.4 Battery : Exide

17.5 DG Panel : Microprocessor based engine mounted as per DG Set Manufacturer

17.6 Motors : Crompton / Siemens.

17.7 Fans : Almonard/Equivalents

17.8 Pipes : TATA.

17.9 Starters : L & T/Siemens.

18.0 SCHEDULE OF TECHNICAL PARTICULARS

18.1 All the installation shall fully conform to the requirement stipulated and the tests shall be carried out as stipulated. Deviations if any shall be clearly brought out in the tender.

Page 34: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 34 of 81

TECHNICAL SPECIFICATION FOR AMF PANEL

1.1 The panels shall be metal clad, totally enclosed, rigid, floor mounting, air insulated, cubical type for use on 415 volts, 3 phase, 4 Wire 50 cycles system. The equipment shall be designed for operation in high ambient temperature and high humidity tropical atmospheric conditions. Means shall be provided to facilitate ease of inspection, cleaning and repairs, for use in installations where continuity of operation is of prime importance.

1.2 The panel shall consists of

POWER CONTROL GEARS

2 Nos. Four pole MCCB with overload and short circuit protections for Mains, Generator with suitable rating (630Amps)

PROTECTION RELAY: Electronic earth fault relay

MICROPROCESSOR CONTROL UNIT (BE-21) incorporating

a) Functions:

Mains supply failure monitor (3 phase voltage sensing)

Supply failure timer

Restoration timer

3 impulse automatic engine start / stop & failure to start lock out

Generator Voltage, current & Frequency sensing — RPM indication

Battery voltage sensing

b) Selector switches & push buttons:

Manual / Auto / Test Selector switch

Generator START / STOP

Generator Breaker Close / Trip; Mains Breaker Close I Trip

c) Indications:

DG ON, DG Breaker ON; Mains Breaker On; Mains ON

d) Metering:

Combined digital meter to measure Volts; Amps; Frequency

Combined digital meter for kVA,kW,PF

Page 35: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 35 of 81

Digital display type kWH

• Battery charger shall consisting of: SMPS based automatic battery charger with DC Voltmeter; DC Ammeter Selector switch for trickle/off/boost, auto/manual switch for boost to float changeover

• Copper bus bar

1.3 The equipment shall be designed to confirm to the requirements of:

a) IS 4237 - General requirements for switchgear and control gears for voltages not exceeding 1100 volts.

b) IS 2147 - Degree of protection provided by enclosures for low voltages switchgear and control gear.

c) IS 375 - Marking and arrangements of busbars. Individual equipment housed in the power control to the following IS specifications:

i) Air /Moulded case circuit breakers - IS 2516 (Part I & II/Sec.1) 1977

ii) Fuse switch and switch fuse units - IS 4064: 1978.

iii) HRC fuse links - IS 1108: 1962 or IS 9114: 1979.

iv) Current Transformer - IS 2705.

v) Voltage Transformer - IS 3156.

vi) Relays - IS 3231.

vii) Indicating Instruments - IS 1248.

viii) Integrating Instruments - IS 711.

ix) Control Switches and push buttons IS 6875.

xi) Auxiliary contractors - IS 2959.

Page 36: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 36 of 81

1.4 CONSTRUCTIONS:

The panels shall be:

i) Of the metal enclosed, indoor, floor mounted free standing type.

ii) It shall be made up of the requisite vertical section, which when coupled together shall form continuous dead front switch boards.

iii) Provide dust and dump protection, the degree of protection being IP 65 to IS 13947.

iv) Be readily extensible on both sides by the addition of vertical sections after removal of the end covers. Each vertical section shall comprise:

i) A front framed structure rolled / folded sheet steel channel section of minimum 3mm thick, rigidly bolted together. This structure shall house the components contributing to the major height of the equipment, such as circuit breaker cassettes, fuse switch units, main horizontal bus bars, vertical risers and other front mounted accessories.

ii) The structure shall be mounted on a rigid base frame of folded sheet steel of minimum 3mm thick and 100mm height. The design shall ensure that the weight of the components is adequately supported without deformation or loss of alignment during transit or during operation.

iii) A cable chamber shall house the cable end connections of power / control cable termination. The design shall be to ensure generous availability of space for easy installation and maintenance of cabling, and adequate safety for making in one vertical section without coming into accidental contact with live parts in and adjacent sections.

iv) A cover plate at the top of the vertical section, provided with a ventilating hood where necessary. Any aperture for ventilation shall be covered with a perforated sheet having less than 1mm diameter perforated to prevent entry of vermin.

v) Front and rear doors shall be fitted with nuts/bolts including neoprene gaskets with fasteners designed to ensure proper compression of the gaskets. When covers are provided in place of doors, generous overlap shall be assured between sheet surfaces with closely space fasteners to preclude the entry of dust. The height of the panel should not be more than 2400mm. The maximum height of any operating mechanism shall not be more than 2100mm. The total depth should be adequate to cater for proper cabling space.

vi) Doors and covers shall be of minimum 14 guage sheet steel. All sheet steel work forming the exteriors or switchboards shall be smoothly finished, leveled and free from flaws. The corners should be rounded. The apparatus and circuits in the power control panels shall be so arranged as to facilitate their operation and maintenance and at the same time to ensure the necessary degree of safety.

Apparatus forming part of the power control panels shall have the following minimum clearances:

i) Between phases - 25 mm

ii) Between phases and neutral - 25 mm

iii) Between phases and earth - 25 mm

Page 37: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 37 of 81

iv) Between neutral and earth - 25 mm

If for any reason, the above clearances are not available suitable insulation shall be provided. Clearance shall be maintained during normal services conditions.

Creepage distances shall comply to those specified in relevant standards. All insulating materials used in the construction of the equipment shall be arranged in multi-tier formation, except that not more than two air circuit breakers shall be housed in a single vertical section. Metallic / insulated barriers shall be provided within vertical sections and between adjacent sections to ensure prevention of accidental contact with:

i) Main bus bars and vertical risers during operation, inspection or maintenance of functional units and front mounted accessories.

ii) Cable termination of one functional units, where working of those of adjacent unit / units.

All covers providing access to live power equipments / circuits shall be provided with tool operated fasteners to prevent unauthorized access. Provision shall be made for permanently earthing the frames and other metal parts of the switch gear by two independent connections.

1.4 METAL TREATMENT AND FINISH:

All steel work used in the construction of the switchboards should have undergone a rigorous metal treatment process as follows:

a) Effective cleaning by hot alkaline degreasing solution followed by cold water rinsing to remove traces of alkaline solution.

b) Picking in dilute sulfuric acids to remove oxide scales and rust formation, if any, followed by cold water rinsing to remove traces of acidic solution.

c) A recognized phosphating process to facilitate durable coating of the paint on the metal surfaces and also to prevent the spread of rusting in the event of paint film being mechanically damaged. This again, shall be followed by hot water rinsing to remove traces of phosphate solution.

d) Passivating in de-oxalite solution to retain and augment the effects of phosphating.

e) Drying with compressed air in a dust free atmosphere.

f) Primer coating, with two coats of highly corrosion resistant primer, applied wet on stove dried under strictly controlled conditions of temperature and time.

g) A finishing coat of stoving synthetic enamel paint to the specified shade of IS. The total thickness of paint should not be less than 25 microns.

Page 38: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 38 of 81

1.5 BUS BARS

1. The bus bars shall be air insulated and made of high conductivity, electrolytic grade tinned copper conductor. High tensile bolts and spring washers shall be provided at all bus bar joints.

2. The main phase bus bars shall have continuous current rating throughout the length of each power control panel, and the neutral busbars shall have a continuous rating of atleast 50% of the phase bus bars.

3. Bus bars shall be colour coded for easy identification of individual phases and neutral and protective earth.

4. CURRENT TRANSFORMER: Current transformer shall comply with the requirements of IS 2705. They shall have ratios, outputs and accuracy's as specified / required.

5. INDICATING / INTERGRATING METERS: All indicating instruments shall be of flush mounting industrial pattern, conforming to the requirements of IS 1248. The instrument shall have non-reflecting dial, clearly divided and legibly marked scales and shall be provided with adjusting devices in the front.

6. CABLE TERMINATION: Cable entries and terminals shall be provided in the switch-board to suit the number, type and size of aluminum conductor, power cable and copper conductor control cable specified in the detailed specifications.

7. Provision shall be made for top or bottom entry of cables as required. Generous size of cabling chambers shall be provided, with the position of cable glands and terminals such that cables can be easily and safely terminated. The minimum depth of the panel shall be restricted to 1600 mm for this purpose.

8. Barriers or shrouds shall be provided to permit safe working at the terminals of one circuit currents without accidentally touching that of another live circuit. Cabling risers shall beadequately supported to withstand the effects of rates short circuit currents without damage and without causing secondary faults. Cable sockets shall be of copper and of the crimping type as specified.

1.6 CONTROL WIRING:

1. All control wiring shall be carried out with 1100 / 660 V grade single core PVC cable

conforming to IS 694 / IS 8130 having standard copper conductor of minimum 2.5 Sqmm section for potential circuits and 2.5 mm section for current transformer circuits. Wiring shall bear neatly bunched, adequately supported and properly routed to allow for easy access and maintenance.

3. Wire shall be identified by numbered ferrules at each end. The ferrules shall be of the ring and of non-detoriating materials. They shall be firmly located on each wire so as to prevent free movement. All control circuit fuses shall be mounted in front of the panel and shall be easily accessible.

Page 39: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 39 of 81

1.7 TERMINAL BLOCKS:

Terminal blocks shall be of 500 volts grade of finger touch proof type. Insulating barriers shall be provided between adjacent terminals.

1.8 LABELS:

Labels shall be on anodized aluminum, with white engraving on black background. They shall be properly secured with fasteners.

1.9 TESTS:

Routine tests shall be conducted on each power control panel in accordance with CI 81,2.2 of IS

8623 and shall comprise:

i) Inspections of the power and control circuits including inspection of wiring and electrical operational tests where necessary.

ii) Dielectric tests.

iii) Checking of protective measures and electrical continuity of the protective circuits.

1.10 STORING:

The panels shall be stored in a well ventilated dry places. Suitable polythene covers shall be provided for necessary protection against moisture.

1.11 ERECTION:

Switch boards shall be installed on suitable foundation. Foundation shall be per the dimensions supplied by the panel manufacturer. The foundation shall be flat and level. Suitable grouting holes shall be provided in the foundation. Suitable MS base channel shall be embedded in foundation on which the panel can be directly installed. The switch boards shall be properly aligned and bolted to the foundation by bottom plate or top plate as the case may be, by using brass Siemens type compression glands. The individual cables shall then be led through the panel to the required feeder compartments for necessary terminations. The cables shall be clamped to the supporting arrangements. The switch board earth bus shall be connected to the local earth grid.

1.12 PRE-COMMISSION TESTS:

Panels shall be commissioned only after the successful completion of the following tests.

The tests shall be carried in the presence of architect's representative.

a) All main and auxiliary bus bar connections shall be checked and tightened.

b) All wiring terminations and bus bars joints shall be checked and tightened.

c) Wiring shall be checked to ensure that it is according to the drawings.

Page 40: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 40 of 81

d) All wiring shall be tested for insulation resistance by a 1000 Volts Megger.

e) Phase rotation tests shall be conducted.

f) Suitable injection tests shall be applied to all the measuring instruments to establish the correctness and accuracy of calibration and working order.

g) Suitable injection tests shall be applied to all the measuring instruments to establish the correctness and accuracy of calibration and working order.

h) All relay and protective devices shall be tested for correctness of settings and operation by introducing a current generator and ammeter in the circuit.

2.0 Moulded Case Circuit Breakers:

2.1 General

• Moulded case circuit breakers shall be incorporated in the PCC/MCC wherever required and shall be of current limiting type and preferably double break.

• MCCBs shall confirm to IS 13947-1/IEC 947-1 for general rules and IS 13947-2/IEC 947-2 for circuit breakers in all respects.

• MCCB should be suitable for horizontal & vertical mounting and Line -Load reversibility and shall be suitable for Isolation.

• MCCB shall be suitable for three phase 690 V, 50Hz, AC with a rated insulation voltage of 750 V AC and impulse withstand of 8 kV .

• The MCCB shall be available in four pole version (selectable neutral protection at 0, 50% & 100%).

• The MCCB shall provide Class II insulation between the front and internal circuits.

• All the breakers shall have tropicalisation as a standard feature.

2.2 Construction:

• The MCCB case & cover shall be made of high strength heat resistant and flame retardant thermosetting insulating material.

• The operating handle shall be quick make, quick break trip free type.The operating handle shall have suitable 'ON','OFF','TRIPPED' indicators.

• In order to ensure suitability for isolation complying with IS13947-2/1EC947-2, the operating mechanism shall be designed such that the toggle or handle can only be in 'OFF' position.

• Three phase MCCBs shall have a common operating handle for simultaneous operation and tripping of all the three phases.

• It shall be possible to "seal on" the thermal-magnetic or electronic trip units to prevent unauthorized access to the settings.

Page 41: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 41 of 81

• It should be possible to interchange the trip units at site.

2.3 Rating & Breaking Capacity:

• The rating of the circuit breaker shall be as per the drawings and schedule of quantities.

• The Service Breaking Capacity (Ics) in kA for different ratings at 415V AC, 50Hz, at 0.2 p.f shall be as follows:

25kA for ratings upto 100A

35KA for ratings above 100A and upto 250A

45KA for ratings above 250A and upto 630A.

2.4 Protection:

• All breakers upto 250A shall have thermal-magnetic trip unit with adjustable overload protection and fixed magnetic protection.

• The MCCBs ratings above 250A shall be fitted with electronic trip unit. The overload setting adjustable from 40% to 100% of the nominal current(In).

• It should be possible to have one or more LED indication(s) on the electronic release -

(1) for overload as a pre-trip alarm

glowing at 90% of rated current(Ir).

flashing at 105% of rated current(Ir).

(2) fault trip indication by LED locally on the electronic release for 0/C, S/C & E/F( if supplied) wherever release with Communication option(COM) is specified.

• The short circuit protection should be adjustable from 2 to 10 times the rated current (Ir) . The Instantaneous Short Circuit protection to be fixed, without any time delay at 11 times the nominal current (In).

• The Earth fault protection, if specified in schedule, shall have adjustable sensitivity with adjustable time delay settings.

• It shall be possible to fully co-ordinate the over-load & short-circuit tripping of the circuit breakers with the upstream and downstream circuit breakers to provide Total Discrimination.

2.5 Accessories:

• MCCBs shall be provided with the following accessories, if specified in schedule and all these devices shall be fittable at site. Each of these units shall incorporate a pre-wired terminal strip which is accessible from the front of the breaker without removing the cover. Preferably, the Shunt trip release and under voltage release shall be snap-in type.

- Under voltage

Page 42: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 42 of 81

- Shunt trip

- Alarm switch

- Auxiliary switch

- Motor operated Mechanism

2.6 Interlocking:

• MCCBs shall be provided with the following interlocking devices for interlocking the door of the switchboard.

• Handle interlock to prevent unnecessary manipulations of the breaker.

• Door interlock to prevent door being opened when breaker is in ON or OFF position

• Door-interlock defeat to open the door even if the breaker is in ON position.

• Front operated rotary handle should have OFF-position pad-locking facility.

2.7 Testing:

• Test certificate

• Original Test certificate of the MCCB as per IS13947-2/1EC947-2 shall be provided on request

4.0 Contactors

• Contactors shall comply with IS 13947 1 for general rules and IS13947-4-1 for standards pertaining to contactors and motor starters. The contactor shall be capable of withstanding breaking & making capacities per following:

AC3 Category AC4 Category

Making Current - 10 times Rated Current 12 times rated current

Breaking current - 8 times Rated current 10 times rated current

• Contractor shall be capable of withstanding an impulse voltage of 8KV and have an insulation voltage of 1000V.

• The Contractors shall be capable of frequent switching and should operate without any deration at 55 deg. C for AC3 application..

• The coil shall have 3 terminals and the insulation class shall be preferably H class, to sustain frequent switching operations. The auxiliary contact block shall have a switching capacity of 240V at 2A.

• Contactors shall have one auxiliary in-built and it shall be possible to have additional NO & NC contacts in steps of two.

Page 43: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 43 of 81

4.1 Thermal Overload Relay

• The Thermal Overload Relay (TOR) shall comply with IS 13947-1 for general rules and IS 13947-1 for standards pertaining to contactor and motor starters and shall be designed for AC3.

• The TOR shall be suitable for Type 1 and Type 2 coordination as per suitable clause in the relevant Indian Standards.

• The TOR shall be capable of offering differential protection and shall be ambient compensated type, operable upto 70 deg. C.

• The TOR shall be capable of withstanding short circuit equal to seventeen times the rated thermal current (17 le).

• The TOR will be tripping class 10A as a standard or class 20 for certain applications where specified.

• The TOR should have built in single phasing protection and phase unbalance protection as per IEC947-4.

• It shall be possible to mount the TOR on the underside of the contactor directly.

• The design of the terminal shroud shall be such that it offers complete protection against direct finger contact with the power terminal, as under IP 20 protection.

• The TOR shall have in built NO & NC contact.

• The "Reset" operation shall be clearly distinguished from the "Stop" operation.

• The TOR shall have separate "Stop" and "Test" button.

• The setting shall be of the adjustable type and there should be a provision of sealing to make the same tamper proof.

• The TOR shall be suitable for Aluminium termination, with a maximum permissible temperature rise of 65K, at the terminals, with an ambient temperature of 40 deg. C.

• All the TORs shall have tropicalization as IEC 68 series as a standard feature.

3.0 INSTRUMENT TRANSFORMERS:

a) Current Transformers:

Current Transformers shall be in conformity with IS: 2705 (Part I, II and III) in all respects. All current transformers used for medium voltage applications shall be rated for 1.1KV, current transformers shall have rated primary current, rated burden and class of accuracy as specified in the schedule. However, the rated secondary current shall be 5 A unless otherwise specified. The acceptable minimum class of various applications shall be as given below:

Measuring : Class I

Page 44: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 44 of 81

Protection : Class 10 P. Current transformers shall be capable of withstanding without damage, magnetic and thermal stresses due to short circuit fault of 35 MVA on medium voltage system. Terminals of the current transformers shall be marked permanently for easy identification of poles. Current transformers shall be provided with Earthing terminals for earthing chassis frame work and fixed part of the metal casing (if any).

Current transformers shall be mounted such that they are easily accessible for inspection, maintenance and replacement. The wiring for CTs shall be copper conductor, PVC insulated wires with proper termination lugs wiring shall be bunched with cable straps and fixed to the panel structure in a neat manner. TESTING: 1. Instrument transformers shall be tested at factory as per IS: 2705 and IS: 3156. The test shall incorporate routine tests. Original test certificates in triplicate shall be provided. 2. Meters shall be tested as per IS: 1148. The tests shall include routine tests. Original test certificate in triplicate shall be furnished. 3. Suitable injection tests shall be applied to the secondary: a) Circuit of every instrument to establish the correctness calibration and working order. a) All relays and protective devices shall be tested to establish correctness of setting and operation by introducing a current generator and an ammeter in the circuit.

TECHNICAL SPECIFICATION FOR ACOUSTIC ENCLOSURE 1. SCOPE OF SUPPLY: Supply of containerized type ACOUSTIC ENCLOSURE suitable for 1 No. 200 KVA DG set driven by radiator cooled diesel engine. 2. DESCRIPTION: The acoustic enclosure shall be of free standing, floor mounting type integral with the DG set. The enclosure shall be provided with rugged heavy-duty structural steel base frame with chequered plate flooring on which the DG set is to be mounted. The enclosure shall be prefabricated factory-built and modular in construction, so that it can be easily assembled at site around the DG set. The enclosure shall consist of acoustically treated panels housed in rugged steel frames, which shall be bolted together to from the body of the enclosure. Sliding doors shall be provided, on either side, which shall also be acoustically treated, thereby providing easy access to the DG set while minimizing the operating space requirements. The construction of the acoustic enclosure shall be such that with both the acoustic doors open on the either side, full access is available to the engine and alternator. For fresh air inlet into the system a parallel baffle air inlet silencer shall be provided. Additionally, to augment the fresh air inlet requirements, a forced air ventilation duct with associated silencer shall be provided above the alternator. For hot air discharge, an acoustic discharge plenum shall be provided in front of the engine radiator, for discharge of hot air into the surroundings through a parallel baffle air outlet silencer. The enclosure shall have suitable openings in the roof module for exhaust piping.

Page 45: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 45 of 81

3. CONSTRUCTIONAL FEATURES : a. The construction and design of the Acoustic enclosure shall be very rugged, durable and shall be virtually maintenance free. b. The acoustic panels shall be filled with a special grade high-density mineral wool retained on the inside by perforated GI sheets specially designed for optimum sound attenuation. c. The outer surface of the Acoustic Panels shall be fabricated of performed 16G corrugated CRCA sheet steel of a SAIL make only. All sheet steel frames shall be of 16G CRCA sheets of SAIL make only. d. All structural members such as angles / channels used in the construction of the enclosure frame shall of TISCO / SAIL make only. e. All materials used for Acoustic Enclosure shall be fire resistant / fire retardant grade. f. The sheet steel treatment shall consist of degreasing, derusting and phosphating followed by two coats of zinc chromate primer, followed by two coats of Zinpholite surface for superior corrosion resistance and two coats of finish paint. g. For effective Acoustic sealing, necessary gasketing material shall be provided. h. All hardware and fittings used shall be passivated with zinc. 1. PERFORMANCE: With the above Enclosure, the sound pressure levels when measured at a distance of 1 meter outside the Acoustic Enclosure shall be around 70 dB (A) under free field conditions. Notes: i. The above noise level is defined with all background ambient noise levels from any other source being less than 70 db (A) so as not to influence this noise level. ii. The section of the exhaust piping within the acoustic enclosure from the engine exhaust manifold onwards upto and including the Residential silencer, must be adequately cladded with thermal insulation to limit surface temperature as also reduce noise level to less than 70 db (A). 5. DIMENSIONS: It shall be ensured that at least 1000 mm (min.) clear space is available all around the Acoustic Enclosure to ensure free air flow for the Genset as required and to facilitate accessibility for generator operation and routine maintenance. The enclosure shall be provided with suction fans to ensure that the adequate cooling and combustion air is made available to the engine and the temperature within the enclosure is limited to 5 deg. C above ambient. The fan shall be designed with sufficient static to draw the requisite quality of air from the duct provided for this purpose. Calculations shall be furnished to prove the adequacy of the ventilation system offered. The suction fans shall start automatically when the temperature in the enclosure reaches 40 OC and shall continue to run for 5 to 10 minutes after the load is disconnected. A temperature controller shall be provided for this purpose housed in sheet steel enclosure. Two light points controlled by a switch complete with 36W fluorescent Luminaire and lamps shall be provided. Provision shall also be made for fixing a heat detector inside the Necessary openings shall be made for the entry of power cable and control cables, fuel piping, exhaust piping, air inlet pipe etc. With the installation of the acoustic enclosure, there shall not be any de-rating of the DG set. The maximum temperature of oil and water shall not exceed the limits prescribed by the manufacturer of the engine. The DG set shall give rated output continuously. The ventilation system shall be designed to provide an air volume of not less than 80,000CFM whenever the DG set is in operation.

Page 46: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 46 of 81

The ventilation fan shall be of the axial flow type designed to handle the static pressure estimated based on the inlet air duct size and length.

Brief Technical Particulars of Diesel Generator Set (To be filled up by Vendors)

No change in make and model will be changed after submission of tender S.No. Description Bidder’s Compliance

1 Source 2 Manufacture 3 Engine

3.1 Engine Model 3.2 Engine Rating 3.3 Engine Power:

a) Gross BHP b) Net BHP

3.4 No.of Cylinders 3.5 Engine RPM 3.6 Aspiration 3.7 Type of starting 3.8 Type of Fuel 3.9 Type of Cooling 3.10 Recommended lube oil change 3.11 Over haul 3.12 Systems ( flow diagram is to be enclosed)

a) Governing arrangement b) Cooling systems c) Fuel d) Lubrication e) Exhaust f) Air filtration, dry type/other type h) Protection

3.13 Type of coupling 3.14 Type of silencer 3.15 Maximum ambient temperature 3.16 Speed Regulation 3.17 Efficiency 3.18 Standard/optional accessories 3.19 Weight of the Engine 3.20 Engine Protections provided 3.21 Noise level at 1 mtr from the set

4 Alternator

4.1 Alternator make 4.2 Alternator Rating (Design) 4.3 Continuous output rating

Page 47: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 47 of 81

4.4 Maximum rating kW @ 0.8 P.F 4.5 Harmonic distortion level

4.6 Rated voltage 4.7 Full load current 4.8 Excitation:

a) Excited voltage, DC volts b) Excided current

4.9 Overload capacity 4.10 Voltage regulation 4.11 Accessories required 4.12 Degree of protection 4.13 Class insulation 4.41 Weight of the Alternator

5 General

5.2 After sales service 5.3 Annual maintenance charge 5.4 Spares availability 5.5 Spares required for Engine & Alternator 5.6 Over all Dimensions 5.7 Weight of the total set 5.8 Foundation details 5.9 Operating cost 5.1 If any other requirements

6 Acoustic Enclosure

6.1 Dimensions 6.2 Sound level at 1 mtr from the enclose

Signature of the Contractor

Page 48: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 48 of 81

Brief Technical Specifications for 200 kVA Genset. Engine: The engine shall be of In Line multi-cylinders, vertical, 4 stroke, Direct injection, water Lice c type, developing the rated Horsepower at a speed of 1500 .krpm. The engine shall be provided with an Hour meter to record the hours of operation. Suitable engine heaters shall be provided to ensure quick starting of the engine after prolonged shut off where necessary. Aspiration ( TC.TA or suitable) Engine Cooling: An engine driven centrifugal pump shall be-employed to circulate the coolant through a cooling, radiator with an axial blower fan. A temperature gauge shall be provided with contacts for stopping the engine on high temperature Lubrication: Pressure lubricating oil system with an engine driven pump shah be provided to cover to complete engine, with built in oil coolant heat exchangers. Full foam filters removable elements, shall be provided and these Shall he located at easily accessible location for ease of maintenance The supply shall include first filling of lubricating oil. An oil, pressure gauge shall be provided to monitor the lubrication oil pressure. The gauge shall, be provided with contacts for stopping the engine on Failure of lubricating oil flow. Governor: The governor shall be of electronic type suitable for monitoring constant engine speed within the specified limits For auto parallel and auto load sharing operation. Exhaust: The exhaust piping system shall be supplied with a residential silencer. The exhaust the piping the silencer shall be wrapped with rock wool and/or calcium silieate. The outside shall be neatly wrapped with aluminum cladding. The exhaust line shall he extended beyond the beyond the height of the utility building roof as required by pollution control norms. Daily Service Tank: The supplier shall supply and install Daily Service Tank of sufficient capacity 350 Its to enable running of the generator set for min 8 hrs to max 12 hours continuous run. The Daily service Tank shall be fitted with necessary fuel gauge with shut off cocks.

Engine Specification: 1. In line 6 Cylinder Engine 2. Rated output kW 3. Rated output HP 4. Cubic Capacity: 8.86 Hrs 5. Aspiration: TA 6. Speed: 1500 rpm

• Lubricants oil Change period hrs : 500 Hrs • Lubricants oil Sump Capacity Ltr : 27 Ltr

Page 49: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 49 of 81

• Coolant Capacity Hrs : 32 • Governing ISO8528 part V : G3 • Noise level : dBA < 75 • Fuel Consumption :

@ 100% load Ltr/hrs: 45.9 @ 75% load Ltr/hrs: 34.4 @ 50% load Ltr/hrs: 25.2 • Fuel tank Capacity : 460 to 500 Ltr • Dry Genset weight canopy in kg : 3900 kg • Wet Genset weight with canopy in kg : 4300 kg • Overall dimensions LxWxH (mm) : 4300 x 1700 x 1970 mm • Height Including Silencer (mm) : 2615 mm • Canopy : Whether Proof • Rating: control system, starting facility, Safety, Shutdown, Display

Note: Kindly refer detailed specification attached herewith filling the tender.

Page 50: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 50 of 81

4. Electronics Engineering Department :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

High Definition USB Document Camera                              8.0 Megapixel camera; For Microsoft Windows Vista, 7, 8, 8.1, 10, 3264 x 2448 pixels when directly connected to PC or Mac Up to 30 fps live video capture (at full HD) 12x continuous digital zoom Full autofocus lens; USB 2.0 Video Class (UVC) interface  

2

LCD Projector                                                                         Smart LCD Projector model EB-575Wi or equivalent, 0.59” with MLA (D8), WXGA, White Light Output (Normal / Eco) 2,700lm / 1,500lm, Sound Output (built in speaker) etc. 

3

Wacom tablet                                                                      Intus modelWacom CTH‐490/B1‐CX Small Comic Pen and Touch Tablet (6.7 inch), Mint Blue  

4

 Microwave Test Bench (Klystron Based)                          Solid State Klystron Power Supply, VSWR Meter  • Components : Klystron Mount, Klystron Tube 2K25, Isolator, Frequency Meter (DRF), Variable Attenuator, Slotted Section with probe carriage, Tunable Probe, Detector Mount, Movable Short, Matched Termination, Slide Screw Tuner, Fixed Short • Accessories :Cooling Fan, Waveguide Stands, BNC Cable, Mains Cords, Fasteners, Nvis 9002A

5

 Microwave Test Bench (Gunn Based)                               Solid State GunnPower Supply, VSWR Meter  • Components : Gunn Dioide, Isolator, Frequency Meter (DRF), Variable Attenuator, Slotted Section with probe carriage, Tunable Probe, Detector Mount, Movable Short, Matched Termination, Slide Screw Tuner, Fixed Short • Accessories :Cooling Fan, Waveguide Stands, BNC Cable, Mains Cords, Fasteners, Nvis 9002A

6

  Sampling & Reconstruction                                               Crystal controlled pulse generator Demonstrates sampling and reconstructed as per Nyquist criterion On‐board synchronized analog signal generator Six, switch selectable sampling frequencies Sampling 

Page 51: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 51 of 81

pulse duty‐cycle selectable Internal/ External sampling signal selectable Separate sample and sample/hold outputs available 

7

 TDM Pulse Amplitude Modulation/Demodulation        Crystal controlled clock On‐board sine wave generator(synchronized) On‐board pulse generator8 4 Analog input channels sampled and time division multiplexed Four switch selectable sampling frequencies Pulse duty cycle selectable Internal/External sampling selectable 

8

TDM Pulse Code Modulation Transmitter                        Crystal Controlled Clock On‐board Sine wave generator(Synchronized) 2 TDM Analog Channels Fast & Slow modes for real time operation and data flow examination Error check code options (odd‐even parity, Hamming Code) 4 Switched faults allow different Error Check Options PC ‐ PC Communication via RS232 interface

9

 TDM Pulse Code Modulation Receiver                                                                                  Input accepts two channel multiplexed data On board De‐multiplexed PCM Receiver On board L. P. Filter Fast & Slow modes for real time operation and data flow examination On board PLL for clock regeneration On board sync code detector Error +check code options Odd or Even Parity‐Single bit error detection Hamming code single bit error detection and correction 4 Switched faults allow different error check code option PC ‐ PC Communication via RS232 interface

10

 Delta, Adaptive Delta and DeltaSigma Modulation/ Demodulation                                                                        Transmitter and Receiver on same board Clock generation from crystal Switch selectable sampling rates Four on‐board generators at 4 different frequencies (synchronized) Separate adjustable DC level Selectable integrator gain setting (by switch or control circuit) On board 4th order Butterworth low pass filter Unipolar to Bipolar converter on board

Page 52: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 52 of 81

11

 Data Formatting and CarrierModulation/ Transmitter                                                                             On‐board Carrier generation circuit (Sine waves synchronized to  transmitter data) On‐board in phase and quadrate phase carrier for QPSK modulation  and DQPSK Different data conditioning formats NRZ (L), NRZ (M), RZ, Biphase (Manchester), Biphase (Mark), AMI, RB, differentially encoded dibit pair  FSK, PSK, ASK ,QPSK & DQPSK carrier modulation Variable carrier and modulation Off‐Set Variable carrier gain On‐board Unipolar to Bipolar conversion On‐board data inverter 

12

Data Reformatting & Carrier Demodulation Receiver                                                                                                      7 different data reconditioning formats NRZ (M), RZ, AMI, RB Biphase     (Manchester), Biphase (Mark), differentially encoded dibit to NRZ data  ASK, FSK, PSK, DPSK ,QPSK & DQPSK carrier demodulation Output gives 2 Channels TDM multiplexed data output On ‐ Board Biphase Clock recovery circuit On ‐ Board data squaring circuit and differential decoder On ‐ Board Butterworth filters ‐ 4th Order

13

 PAM‐PPM‐PWM  Modulation & Demodulation             PAM‐PPM‐PWM modulation & demodulation techniques using natural & flat‐top sampling,On‐board filter and ac amplifier

14  Differential Pulse Code Modulation (DPCM)                   On board  DPCM  transmitter & receiver , audio input & output processing on same board

15

 PN Sequence Generator                                                     On board four selectable clock frequencies & six selectable data sequence External clock upto 1 MHz Functional blocks indicated on board mimic

16

 Error Detection and Correction‐Cyclic Code                   On‐board Data and Code clock generation On‐board data generator, BCD rotary switches for Data Selection LED Numeric display Multiple data rate and code rate selection Seven bit code for four bit running or Static data

Page 53: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 53 of 81

17

 Understanding Block Code Encoder                                 On‐board clock generation for Data and Code. On‐board data generator. On board error generator block BCD rotary switches for Data Selection. LED Numeric display. Single bit error detection and correction. Default and manual H‐matrix selection Exhaustive learning material 

18

 Understanding Block Code Decoder                                 On‐board clock generation for Data and Code. On‐board data generator. On board error generator block BCD rotary switches for Data Selection. LED Numeric display. Single bit error detection and correction. Default and manual H‐matrix selection Exhaustive learning material 

19

Convolutional Encoder Selectable rate: N=3, rates ½ ; N = 7, rate ¾. Manual and Continuous mode operation Encoder Code tree On‐board data and clock generation On board error generation 

20

  Convolutional Decoder                                                      Selectable rate: N=3, rates ½; N = 7, rate ¾. State and trellis diagram Support Hard decision and soft decision decoding Decoded data bit display Single Supply 

21

  DSB/SSB AM Transmitter                                                   On‐board audio oscillator, band pass filters, 455 Khz &1Mhz carrier generator, transmitting antenna and speaker & DSB/SSB transmitter on same board 

22

  DSB/SSB AM Receiver                                                         On‐board local oscillator,mixer,bit frequency oscillator, RF Amp, IF Amps, detectors, audio output, receiving antenna &DSB/SSB receiver on same board

23

 Frequency Modulation/Demodulation                            On‐board audio oscillator, 2 types of FM modulators & 5 different types of demodulator samplitude limiter & filter, effect of  noise in FM on same board 

24

 Four Channel Analog Time Division Multiplexing           Experiments can be performed like: DSB & DSBSC AM reception & detection  by envelope detectors & Study of time division multiplexing &demultiplexing of analog signals 

Page 54: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 54 of 81

25

 Frequency Division Multiplexer /Demultiplexer             On board frequency division multiplexing & demultiplexing with sinusoidal &Audio Input, DSBSC modulation/demodulation on same board &Study of fourier transform of DSBSC modulation

26

 Powerscope                                                                           Floating measurements with completely isolated inputs; X100 and X10 attenuation for floating measurements; Built‐in Ramp and Pedestal Firing Circuit; 1500 V max input for floating measurements; 30 MHz ‐ 5 mV Dual Trace Oscilloscope; Algebraic sum & difference of both channels; Alternate Triggering; Line Trigger; 

27

 Experimental Setup‐Phase Control  using opto‐triac firing circuit                                              firing at ZCD/random firing, Load capacity 1 A, Lamp Load 

28

  Experimental Setup‐Study of Protection Circuits for Power Devices                                                                       Short circuit, Overload and overvoltage, dv/dt, di/dt protections for SCR, IGBT, Power MOSFET 

29

 Embedded practicals and project kit                               8051 Development Board 10 kits Technical Specification:Serial Communication with MAX232, Eight 5mm LEDs, Eight Switches in DIP package, LCD 16x2, Four Seven Segment Displays,ADC 0808 with 555 timer for sampling frequency,ULN 2803 Driver,Two Relays for Switching AC devices.,4x4 Keypad,L293D Motor Driver for DC and Stepper Motors,DS1307 based Real Time Clock,AT2404 EEPROM,ISP or with USB programmer,Serial and USB cables,Power Adapter  LPC2148 Development Board 10 kits: Four or eight LEDs, 16x2 LCD, 4X4 or 1X4 keypad, Two Serial Ports, ISP or with USB programmer, With serial and/or USB cables, With power Adapter PIC Development Board 10 kits(Technical Specification): Support Microcontrollers PIC16F877(and/or PIC18F2520) LCD 16x2, Seven Segments 4 numbers, RTC with battery, Buzzer, Two Relays, Eight DIP Switch, Eight 5mm LEDs, 4 x 4 Keypad, Two Serial Ports

10 

Page 55: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 55 of 81

30

Table top PCB Drill machine Specification: Motor Speed : 20000 RPM Drill bit range : 0.6 mm to 3 mm Working area : 20cm to 30cm Illumination at work area Soldering station SLD‐936ESD or equi. ,HOT Air Gun (SMD Rework StationAST‐850 or equi. ),Magnifying lensesLens Size: 8.5” 

31 Multifunction Printer all in one laserprinter, scanner ,copier and duplex printing  HP or equivalent                 quote auto duplex printing separately 

32

Laptop DELL        /equivalent                                               Specification: Model 3542, Processor: Ci5‐4210U, OS:WIN8, RAM:4GB, HD: 1TB, Graphics: NVIDIA@GeForce@820M 2GB, DVD, 15.6" Screen with warranty and Bag 

Page 56: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 56 of 81

5. CSE Engineering Department

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

1

Desktop Computer Systems Intel Core i5 4570 3.2GHz, 6MB Cache or betterMotherboard Chipset Intel Q85 Series Memory: 4 GB DDR 3 RAM expandable to 16GB; Two DIMM slots; Non-ECC dual-channel upto 1600 MT/s DDR3 SDRAM, Hard Disk Drive: 500GB HDD, 7200 RPM, NCQ Optical Drive: SuperMulti DVD Writer, Graphics: Integrated Graphics, Audio : High Definition Integrated Audio with Internal Speaker, Ethernet : Integrated Gigabit (10/100/1000 NIC) LAN, Slots: min. 3 PCI slots, Bays: 3 bays or more, Ports: Rear I/O (2) USB 2.0 ports, (2) USB 3.0 Ports (1) VGA video port, (1) RJ-45 network connector, (1) RS-232 serial port, 3.5mm audio in/out jacks, PS/2 keyboard and mouse ports, Front I/O, (2) USB 2.0 ports, 3.5mm headphone/microphone jack, Form Factor: MT ( Micro Tower), Power Supply: 180W or higher Active PFC power supply with 85% efficiency, Keyboard/Mouse: PS/2 104 keys keyboard (Same make as PC), PS/2 2 Button Scroll Mouse, Monitor: 18.5” TFT LED Monitor Operating System: Genuine OEM install Microsoft Windows 10 Pro 64-bit, Diagnostic Tool: BIOS Diagnostics, Security: TPM 1.2 Security Chip, SATA port disablement (via BIOS), Serial, parallel, USB enable/disable (via BIOS Optional USB Port Disable at factory (user configurable via BIOS), Removable media write/boot control, Power-On password (via BIOS), Administrator password (via BIOS), Setup password (via BIOS), Support for chassis padlocks and cable lock devices Warranty: 3 yrs onsite warranty Compliance And Certification: Energy Star ver 6 for the given form factor, EPEAT certified in India for the given form factor, WIFI Adapter Integrated in Desktop IEEE and WiFi compliant 64 / 128 bit WEP encryption for a/b/g mode only, AES‐CCMP: 128 bit in hardware, 802.1x authentication, WPA, WPA2: 802.1x. WPA‐PSK, WPA2‐PSK, TKIP, and AES. WPA2 certification, IEEE 802.11i, Cisco Certified Extensions, all versions through CCX4 and CCX Lite WAPI

30

Page 57: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

2

3

4

5

6.

LCD ProjHITACHI 2700 ANS3.5KG, 162 VIDEO INPUT, MCONTROPRESENTOPTION SECURITTEMPLATHDMI ONLINE U3KVA / 96PFC ChaIsolation tequivalen Battery 2for 60 minBackup foLED Mon 600VA UPIn-built 12POWERSFitting of Aand labou2 Tr Split ACopper CMake: Bluequivalen Fitting of Steel withWith all naccessorModel SDCooling CMake: Blu

ector CP-X2541WSI LUMENS6W, 6000-1

MONITOR OL,USB FORTATION , &

TY LOCKINTE FUNCTI

UPS 6 V DC withrger, IGBT ransformert

8 AH, SMFnutes or 10 Numitor)

PS 2V/7 AH SMSAFE or equAir Conditio

ur: Air Conditioondenser 3

ue Star, Volt

f Storage Wh water punecessary ries and lab

DLX 240, StCapacity 20 ue Star or e

WN or equiS, XGA, 100000HRS 2

OUT + USBR JPEG & DONGLE

G (PIN&BAION, NETW

h Dual microbased & O

r, Make :- D

F, Make- Mt

ber PC.( C

MF Battery, uivalent oner with al

oner 3 Star ratedtas, Toshib

Water Coolrifier plumbing bour orage CapaLtr / Hr

equivalent

ivalent : 0000:1, 2PC INPUT

MOUSE

, WIRELES

AR), WORK, 2

o controllerOutput Dualtek or

tek / Okaya

Considering

Make :-

l accessori

d ba or

er Stainles

material,

acity 40 Ltr

T,

SS One

r,

a,

g

1 No

8 No.

5 No.

es

6 Nos.for 3 labs

ss

r, 1 No

.

.

T

Tender –Augus

Page 57 o

t 2016

of 81

Page 58: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 58 of 81

7.

Fitting of Storage Water Cooler Stainless Steel With all necessary plumbing material, accessories and labour Model SDLX 480, Storage Capacity 80 Ltr, Cooling Capacity 40 Ltr / Hr Make: Blue Star or equivalent

1 No

8

Branded Workstation (HP / DELL / EQUIVALENT)Specifications:

NVDIA Quadro K2200 4GB DL-DVI(I) + 2xDP 1s

NO cables included Graphics Operating system load to SATA/SAS 4TB 7200 RPM SATA 1st hard drive 240GB SSD Hard-disk Drive 4TB 7200 SATA 2nd Hard drive 4TB 7200 SATA 3rd Hard drive USB keyboard Optical mouse Linux Installer kit 9.5 mm Slim DVD-ROM 1st ODD single unit packaging Intel Xeon E5-1630v3 3.70 GHz 10MB 2133 4C

CPU 32GB DDR4-2133 (2 X 16 GB) Registered RAM 3/3/3 Warranty Processor Air Cooling Kit

1 No.

9

Fish eye camera Make: Cadcye / Dahua/ CP plus / / EQUIVALENT Specifications:

12 MP camera, Inbuilt Audio, IR-10 Meter, Lens- 1.57mm WDR-DWDR, Day/night (ICR) , ultra DNR IP rating-IP rating, IP 67 and IK10, SD card storage

1 No.

10

Network PTZ camera Make: Cadcye/ Dahua/ CP plus / / EQUIVALENT

1/3’ CMOS image sensor Powerful 20x optical and 16x digital zoom 25/30 fps @ 1.3 MP resolution DWDR, Day/night (ICR) , ultra DNR Up to 255 presets, 8 tour, 5 patterns, 5 auto scan Max 300o /s pan speed, 360o endless pan rotation Built in 2/1 alarm in/out IP66 Mobile s/w: iCMOB, gCMOB CMS s/w : KVMS Pro, vOptimus

1 No.

11 LAN wire (Cat 6) extra with casing capping App 30 meters

12 Installation charges and setting charges - 13 POE (Power over Ethernet) switch – 4 port 1 No.

Page 59: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 59 of 81

14

4 channel NVR Up to 4/8 channel IP camera input H.264/MJPEG dual codec decoding Max 200Mbps incoming bandwidth Up to 5Mp resolution preview & playback HDMI/VGA simultaneous video output 4 channel synchronous real-time playback,

GRID interface ONVIF Version 2.4 conformance 3D intelligent positioning with PTZ camera 2 SATA HDDs up to 8TB, 2 USB(1 USB3.0) Multiple network monitoring: Web viewer,

CMS(DSS/PSS) & DMSS Multi-brand network cameras Support Main Processor Dual-core embedded

processor Operating System Embedded LINUX IP Camera Input 4 channel Two-way Talk 1channel Input, 1channel

Output, RCA Interface 1 HDMI,1 VGA Resolution : minimum 1920× 1080/ 1280×

1024 Compression H.264/MJPEG Resolution 5Mp(2560× 1920)/3Mp(2048×

1536) Record Rate 200Mbps Bit Rate 48~ 8192kbps Record Mode Manual,

Schedule(Regular(Continuous), MD, Alarm), Stop Record Interval 1~120 min, Pre-record: 1~30

sec, Post-record: 10~300 sec Search Mode Time/Date, Alarm, MD & Exact

search (accurate to second), Smart search Backup Mode: USB Device/Network/Internal

SATA burner Ethernet : 1 RJ-45 port (10/100/1000Mbps) Network Function : HTTP, TCP/IP, Ipv4/Ipv6,

UPNP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter,PPPOE, DDNS, FTP,

Alarm Server, IP Search. Max. User Access : 128 users Smart Phone support ( iPhone, iPad,

Android)

1 No.

15 12 v 5 amp power supply for each camera 2 No.

16

2KVA ONLINE UPS system with battery backup o one hr @ full load, Battery VAH reqd.=3024 VAH

Micro controller Based Double Conversion Topology with better control over the voltage Freq. Wide input Voltage & Frequency Window Built in Galvanic Isolation Transformer Auto Sense intelligent control smart PFC charges

1 No.

Page 60: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 60 of 81

Very Low Third Harmonic Distortion < 3% Cold Start High Frequency PWM Based Inverter Using IGBTs Computer Inter face(optional) LCD Display(optional)

17

2KVA Offline UPS 50 min backup, total VAH reqd. = 1560 VAH

Output Power: 1600 Watts Features: Built in automatic Voltage regulation,

Cold Start Capability, Extended Battery Run Time Models, Full Time EMI or

RFI Suppression, Generator Compatibility, Microprocessor Based

Design, PC Interface and Advanced Power Monitoring Software, Printer

Surge Protection, Smart Battery Management, Ethernet line Surge

production, User Replaceable Battery Wave Form: Stepped Sine Wave UPS Type: Line Interactive Segment: Home, Office

1 No.

18

CSE Private Cloud : VMWare View Deployment and Configuration Existing Cloud Infrastructure :

1. Dell Vertex PowerEdge Chasis for 4 Blades, 12 TB storage, PowerEdge M620 4 blades, with 2 x IntelI XeonI CPU E5-2603 0 @ 1.80GHz, 64 GB RAM in each blades, 2 TB HDD in each 4 blades.

2. CSE dept. is having required licenses of VMWare softwares under “Vmware Academic Program“ (VAP)

Proposed Scope of work :

1. Installation of appropriate ESXi stack 2. Installation of vSphere 6.0 or

above. 3. Configuration of vCenter, HA,

Networking, Storage & vMotion. 4. Installation Of View Connection

Server & Replica server with AD Integration.

5. Creation of Base Images with Application set installed inside the VM.

6. Configure the Dedicated Pool for desktop.

7. Configure the Entitlement with

1 No.

Page 61: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 61 of 81

desktop 8. Configure the Workspace &

ThinApp 9. Access of VM/VDI from existing Dell

Wyse Thin Client / browser

19

CSE Private Cloud : Hardware accessories

1. 32 GB RAM compatible to Dell PowerEdge M620 blades and / or

2. 64 GB RAM compatible to Dell PowerEdge M620 blades

3 No.

4 No.

20

RFID Tags Intermec RFID Tags (IT04U00YTT002B) or equivalent Intermec’s flexible RFID Smart Labels and tags provide a versatile architecture that can be used in open or closed loop environments. Thermal transfer or direct thermal printing and chip encoding enable on demand generation of durable RFID labels and tags that can be deployed with confidence to meet a broad range of customer requirements.

25 No.

21

RFID Reader RF Ideas (RDR-7582AKU) RFID Reader AIR ID RF IDEASD READER, 13.56 MHz I CLASS/MIFARE, USB

04 No.

22

RFID Software RedBeam or Impinj RFID Asset Tracking (RB-RAT-1) Android support apps for Inventory, Asset Tracking, Surveillance, Printing

01 No.

23

RFID Sling Bag Tatonka or equivalent Check in RFID B Sling Bag

RFID system for Identification and reminder app [Document wallet with integrated read protection. The new RFID technology is advancing: data stored electronically on RFID chips that are used, for instance, on debit and credit cards, mobile phones, passports and ID cards, are read quickly and without physical contact using remote technology. However, this also attracts criminal interest, so you should protect any of your documents and devices that have this feature. The CRYPTALLOY foil in the Check In RFID B blocks these radio waves, making data theft impossible. Check In RFID B can be worn over the shoulder or attached to a belt. Two zips provide access to the large main compartment. Under the lid are various zip-up pockets for all the various little odds and ends you need when travelling.]

01 No.

24

RFID Wristbands/ MI bands (multi activity) BCI New PDC Smart Woven RFID Wristbands are the ultimate multi-day, high-security event management solution! The special mix of nylon and cotton materials creates wristbands that are soft and extremely comfortable to wear. The combination of precise, multi-color weaving of custom graphics, a high-strength plastic one-way sliding closure and integrated RFID slider result in wristbands that are secure, non-transferable and impossible to counterfeit!

01No.

Page 62: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 62 of 81

25

E-health sensor shield v2.0 for arduinoRaspberry pi and Intel Galileo

02 No.

26

ATIENT POSITION SENSOR (ACCELEROMETER) FOR E-HEALTH PLATFORM unit

01 No.

27

GLUCOMETER SENSOR FOR E-HEALTH PLATFORM

01 No.

28

BODY TEMPERATURE SENSOR FOR E-HEALTH PLATFORM

01 No.

29 Raspberry Pi 2 Starter Kit 06 No.

30

PULSE AND OXYGEN IN BLOOD SENSOR (SPO2) FOR E-HEALTH PLATFORM

01 No.

Page 63: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 63 of 81

31

AIRFLOW SENSOR (BREATHING) FOR E-HEALTH PLATFORM

01 No.

32

GALVANIC SKIN RESPONSE SENSOR (GSR – SWEATING) FOR E-HEALTH PLATFORM

01 No.

33

ELECTROCARDIOGRAM SENSOR (ECG) FOR E-HEALTH PLATFORM

01 No.

34

ELECTROMYOGRAPHY SENSOR (EMG) FOR E-HEALTH PLATFORM

01 No.

35

RFID 13.56 MHz / NFC Module for Arduino / Raspberry Pi

02 No.

36 MATRIX IoT Toolkit with 15 sensors Samsung or equivalent Smart office automation

1 No.

37

Drones with remote control BLADE 180 QX HD quadcopter with SAFE™ (Sensor Assisted Flight Envelope) technology

1 No.

Page 64: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 64 of 81

38

Video Surveillance: IP based PTZ Camera unit with software IDE CP / Sony IoT project Context Awareness

2 No.

camera per unit

39

GPS tracker with navigation system

Map My India Lx350 Car GPS - 3D Navigation System

• OS: Windows CE 6.0 • CPU:Sirf V, 600 MHz • Memory: In-built 4GB Flash memory, DDR2

128MB • SD card: supports up to 8GB

1 No.

40 Sensors with electronic actuators like Zigbee & IR communicators 10 No.

41 IDE & software API tools For connected integrated device app development

01 No.

44

ADXL335 Module 3-axis Analog Output Accelerometer for Raspberry Pi Arduino

05 No.

43

Robohaat-Vibration Sensor Module Vibration analysis Shock detection and event capture health Instrumentation, diagnostics Safety,

02 No.

Page 65: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 65 of 81

44

DHT11 – Humidity and Temperature Sensor

1 No.

45

TCS230 TCS3200D Color Recognition Sensor Module with wide angle lens

On-board the TCS3200 color sensor With removable wide-angle lens, can

2 No.

46

IR Infrared Obstacle / Distance Sensor Module

sensor module output port OUT can be directly connected with the microcontroller

IO port .

1 No.

Page 66: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 66 of 81

47

eZ430-Chronos - Wireless development tool in a watch from Texas Instruments

Texas Instrument

1 No.

48

CDAC IOT Kit CDAC Research kit(Proprietary items) CDAC Ubimote Wi-Fi Mote BLE mote WINGZ Ubi-Sense Ubi-DAQ Debugger

1 Set of 6 kit

49

New

Mini Top

HP Pavilion Mini Laptop S003TU

11.6inch,ProcessorIntel Celeron N3050 1.6GHz ProcessorRAM2GB RAMStorage500GB HDD

1 No.

50

Anti Virus

For ASE lab and ARS PC

2 No.

51

5 in 1 Colour Printer

HP 1036

ARS Staff Advisor work and other promotional imp activities

01No.

52

UPS Invertor 2 KVA 4 Battery T150 H ARS cabin

01 No.

53

External Hard Disk 1 TB ARS cabin

01 No.

Page 67: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 67 of 81

54

Fingure reader Bio metric system ASE Lab for auto student attendance

May be used in other labs 01 No.

55

Visual Presenter high resolution SVGA HitachiHitachi HV1700SX

May be used in other labs 01 No.

56

White Interactive Board Windows supported

E-800 Portable Interactive Whiteboard (Converts Yours Whiteboard to Interactive)

With Interactive Device, Small Mount,10 mtr USB Connector, LED Interactive PEN

Windows supported

aka E - 800 Interactive whiteboard Device converts whiteboard with projector to smart board,you can interactive with the image using stylus. Suitable for Classroom and office. For presentation and Interactive Trainings

01 No.

57

Dell Laptop 3558 or Equivalent Intel Core i3 5th Generation 4GB DDR3 RAM 1TB Harddisk Drive Dedicated 2GB Graphics DVDRW 15.6” Anti Glare LED WIFI, BT, CR Dell Original Carrycase Dell 1 Year Complete Cover Warranty 

3 Nos.

58

ProSAFE® Business 3 x 3 Dual Band Wireless‐AC Access Point  NETGEAR® ProSAFE® WAC730 or equivalent  High Performance 802.11ac Wireless Access Pointfor Multimedia content with Quad Mode Management

4 No.

59

Extreme Switch 48 10/100/1000BASE‐T, 2 1000BASE‐X unpopulated SFP (2 SFP ports shared with 10/100/1000BASE‐T ports), 2 10GBASE‐X SFP+, 1 AC PSU, ExtremeXOS Edge license, connector for external power supply Power Cord,10A,BS546,C13 

2 No.

Page 68: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 68 of 81

60

Public Address System (PA System): Ahuja make DPA-770 amplifier or equivalent 75 WATTS including USB player

2 No.

61

Public Address System (PA System): Ahuja make AWM-520VHL PA VHF Wireless Microphone or equivalent

2 No.

63

Public Address System (PA System): PA Gooseneck Microphones: GM-611M or equivalent With base unit GMB-6C  

1 No.

1 No.

64

Public Address System (PA System): Headband Microphone: HBM-50 or equivalent

2 No.

65

Public Address System (PA System): 2-Way Compact PA Wall Speakers: PS-400T or equivalent

8 Nos.

66

Public Address System (PA System): For Mini-CCF Professional VHF Wireless PA Microphone: AWM-520V2 or equivalent

1 No.

67

Public Address System (PA System): Wiring, Fitting and System Installation

For 2 Class-Rooms

Page 69: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 69 of 81

6. Information Technology Department :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

Q a b (a+b)*q

1

 Dell Laptop L (i5 Win 8.1 Pro) /equivalent Intel core i5 4210U (1.7GHz with Turbo boost upto 2.7GHz, 3M cache), 4GB 1600MHz RAM, DDR3L Memory, 1 TB SATA HDD, Nvidia Geforce Graphics, 15.6” screen size, QM87 chipset, Resolution 1366x768 pixel, HD webcam, Dell Wireless – N 1705 LAN, v4.0 Bluetooth, 4 cell battery with 65W AC power supply, 3in1 card Reader, 2xUSB 2.0, 1xUSB 3.0 (Qty‐2) 

2

2

HP or equivalent ENVY 700xt Desktop Processor: 4th Generation Intel(R) Core(TM) i7‐4790 processor quad‐core [3.6GHz, 8MB Shared Cache] Hard drive: 1TB 7200 RPM SATA Hard Drive Memory: 12GB DDR3‐1600MHz, Graphics: 2GB Nvidia GeForce GT720, Networking: HP WLAN 802.11 b/g/n 1x1 MCard BT Premium Wireless‐N LAN card and   Bluetooth(R )(2x2) Ports: 15‐in‐1 Multi‐slot Media Card Reader, 4 USB Ports (Front/Top), Audio [Front 2USB2.0, Top 2USB3.0] Optical drive: SuperMulti DVD Burner Blu‐ray player and SuperMulti DVD burner Monitor with TFT LED, Keyboard & mouse: HP USB keyboard & optical mouse Memory slots: 4 DIMM Operating system : DOS (5 Qty)

3

3

UPS Emerson /APC/ or Equivalent Make online UPSCapacity – 6 KVA 192v 1 Phase Input/ 1 Phase Output With 1 hour backup Battery should SMF 12v Including Batteries M.S.Rack, Installation.  

1

4

 2.0 ton, 3 star Split Air Conditioner  Nominal Capacity : 1.5 ton.  Cooling capacity : 5.25 kW ± 2%   Function modes: Auto/Cool /Fan/Dry–shall have sleep and power saving modes  Remote handset : LCD display with night glow

1

5

Hewlett‐Packard LaserJet Mono Multi Function Printer –M1005/equivalent Print Resolution – True 1200 x 1200 dpi, Scan resolution – 600 x 600 dpi, Print speed – 14 ppm, connectivity – USB 2.0 High speed, Economode print quality settings prints text with less toner, Input Tray – 150 sheets paper cassette, Network – N. A. , Duplex – Manual, Warranty – 1 Year on site service, by HP (1 Qty) 

1

Page 70: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 70 of 81

6

 Desktop Computer:  Intel 4th generation Core i5/equivalent ‐4570 Processor (Quad Core, 6MB Cache, 3.2GHz, W/HD Graphics 4600), 8GB DIMM (8GB ) DDR3 @ 1600MHz, 500GB @7200 RPM 3.5" SATA Hard Drive, 16 x Half Height DVD +/‐ RW Drive, Intel H 81 Chipset Mother Board, Integrated Intel HD Graphics 4600 (with select CPUs), Integrated Reaktek RTL8151GD Ethernet LAN 10/100/1000, USB Entry Keyboard, Optical Mouse, 18.5" Widescreen Monitor with TFT LED, Internal Business Audio Speaker. Microsoft Windows 8 Professional 64 bit (English) with media CD Tower Chassis + Standard SMPS Warranty: 3 year Next Business Day On‐site Service. (Note: Make DELL or HP only)  

30

7

 Networking Items:1. D‐Link® Passive (Copper) Information  outlet ‐ Part No : NKJ‐C6WHI1B21 & NFP‐0WHI11 Jack Cat 6 Keystone UTP +Face Plate – Single (Keystone Jack, square) (Qty=80)2. D‐Link® Passive (Copper) G600 Cat 6 LAN  cable 305 meter ‐ Part No :NCB‐C6UGRYR‐305 (Qty=05)3. Labour Charges   Rack Dressing (Qty=03)                                                       4. D‐Link® Passive (Copper) Patch cord UTP cat 6 24 AWG ‐ 1 meter Part No : NCB‐C6UGRYR1‐1 (Qty=80)5. D‐Link® Passive (Copper) Patch cord UTP cat 6 24 AWG ‐ 2 meter Part No : NCB‐C6UGRYR1‐2 (Qty=80)6. Labour Charges Cat 6 Cable Laying per Meter & At actual (Qty=300 Meter)7. Labour Charges  I.O Fixing and Punching (Qty=80)8. Labour Charges  Cassing  Running Per Meter ‐ 1", 2" (Qty=250 Meter) 

8

Quanta / EXIDE / Rocket / Leaoch or equivalent make SMF batteries: Capacity: 12V‐100AH, Qty. 30 Nos.  (1) New batteries with installation, commissioning and preventive maintenance per month & with necessary accessories and cabling work needed to connect to existing 20KVA UPS. (2) Servicing of existing 20KVA UPS, if needed. After installation and commissioning of batteries, existing UPS should be in working condition, and then only payment of new supplied batteries will be released. (Buy Back 30 Qty)Warranty: 24 months / 36 months. 

30

9

Canon IT 2002N Xerox Printer/equivalent B/W Laser Multifunctional (Reader/Printer Console), Interface: N/w‐Ethernet 100BASE‐TX / 10BASE‐T, Other: USB 1.1/2.0, Paper Size: A3,A4,B4,A4‐R,B5,B5‐R,A5‐R, Paper Capacity: 250 sheets Old Buy Back‐IR 2016  

1

10

EPSON Business Projector EB – 945 H/equivalent Resolution: XGA, Aspect Ratio‐ 4:3, Brightness: 3000 lumens, Contrast, Ratio: 10000:1, Lamp Life: 5000Hr, Wireless Connection (Optional), Network I/O‐ Wired LAN Projection Technology‐ RGB liquid crystal shutter projection system (3LCD), Warranty: 2 years onsite service for projector & 1 year or 1000 hours for Lamp – whichever comes first by EPSON ( wireless and USB connectivity) 

2

11 8‐port KVM switch Rack mountable with 8 KVM USB cable set  3

Page 71: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 71 of 81

7. Physics Department :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

Laptop DELL /equivalent Specification: Model 3542, Processor: Ci5-4210U, OS:WIN8, RAM:4GB, HD: 1TB, Graphics: NVIDIA@GeForce@820M 2GB, DVD, 15.6" Screen with warranty and Bag

1

2

LCD Projector Epson- EB G6970WU LCD/equivalent Resolution : WUXGA (1920X1200) , Brightness : 6000 lumens, Features: HDMI input, LAN, Wi-Fi Audio: Stereo Contrast Ratio : 5000:1, Throw ratio: 1.26 to 2.30 Aspect Ratio: 12/30/1899 Audio Output : 10 Watt Lamp Life : 5000Hr (Normal), 10000Hr (Eco), Wireless Connection (Optional), Projector Lens : Optical Zoom

1

Page 72: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 72 of 81

8. Chemistry :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

 Desktop Computer:  Intel 4th generation Core i5‐4570 Processor /equivalent (Quad Core, 6MB Cache, 3.2GHz, W/HD Graphics 4600), 8GB DIMM (4GB x 2) DDR3 @ 1600MHz, 500GB @7200 RPM 3.5" SATA Hard Drive, 16 x Half Height DVD +/‐ RW Drive, Intel H 81 Chipset Mother Board, Integrated Intel HD Graphics 4600 (with select CPUs), Integrated Reaktek RTL8151GD Ethernet LAN 10/100/1000, USB Entry Keyboard, Optical Mouse, 18.5" Widescreen Monitor with TFT, Internal Business Audio Speaker. Microsoft Windows 8 Professional 64 bit (English) with media CD Tower Chassis + Standard SMPS Warranty: 3 year Next Business Day On‐site Service. (Note: Make DELL or HP only) 

1

Page 73: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 73 of 81

9. Exam Cell :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

Colour Xerox Machine having RAM, HDD, Back to back printing and scanner having feeder for bulk Back to back quality scanning with related software. Tray capacity 2x 500 sheets. Quote separately for 20 cpm /35 cpm / 45 cpm.

1 No.

Page 74: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 74 of 81

10. Office :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

Pioneer/Local made excellent quality                               Equivalent  Plain, size‐ height 1980 mm, width ‐ 915 mm,                   depth‐485 mm, 18 guage, colour‐Graphite Gray,3 Keys 

6

2 UPS –contact Shri.Sawant V.B.   1 3 Pinters‐Canon2900B/Equivalent  5

4 Printer‐Canan/Epson/ equivalent Heavy Capcity Printer for Sevarth‐ 2 side printing –Contact Shri.Ramtirthkar 

1

5 Printer‐ Canan/Epson/Equivalent Heavy duty Triplicate printing –Contact Shri.Jadhav, Cashier  1

6 Desktop Corei7/4gbram/500Hard Disk/18.5”Led Screen/Key Board/Mouse/Atx Cabinet + SMPS or Intel® i7 Quad Core,1TB HDD,8 GB RAM,DVD RW Drive,20" Monitor ,USB Keyboard and mouse OR LENOVO Think Center 

6

Page 75: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 75 of 81

11. Tilak Hall :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

LCD PROJECTOR Specifications:

• Brightness : 4000 to 5000 AL • Contrast Ratio : 5000 : 1/10,000 : 1 • Display Colour : 1.07 Billion/ or similar • Clear Image Size : 60: to 240” • Zoom Ratio : 1.6X • Compatibility : HDTV Compatibility Video

Compatibility • Interface : HDMI

USB RS232 IR receiver

Accessories : 1. HDMI Cable 2.Roof Mounting Stand

1

Page 76: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 76 of 81

12. Applied Mech Department:

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1 Data Acquisition System for Structural Health Monitoring

1.1 ESS-NI-DAQ Hardware with Sensors, Signal

Conditioning and accessories bundle:

• Compact RIO chassis (8 slot USB) • 4 Ch-Ch Isolated, 24-bit, ±60V,100S/s Universal • AI Module 24-Bit Sigma-Delta ADCs, 51.2 kS/s Max

Samp Rate, 4 Input Simultaneous, Software Selectable IEPE and AC/DC Coupling, Anti-Aliasing Filters, 102 dB Dynamic Range

• +/-10 V, 16-Bit, 100 kS/s/ch, 4-Ch, Simultaneous AO C Series Module

• 8-Channel, 100 ns, TTL Digital Input/Output Module • 24 V, 100 µs, 8-Ch, Sinking DI C Series Module • 24 V, 100 us, Sourcing Digital Output Module • DSub terminal block for screw terminal connectivity to

25 pin DSub C Series modules • 4 Input, 24-Bit, 51.2 kS/s, SW Selectable IEPE &

AC/DC • Strain Relief and Operator Protection • Front-mount terminal block for 25-pin D-Sub Modules • Dual SD Secure Digital Removable Storage Module • WSN C Series Gateway • NI WSN Starter Kit

1.2 1.2 ESS-NI-Virtual Instrumentation Software Bundle: LabVIEW Academic Premium Suite (5 User) Research Site License

1

1.3 Sensor’s and accessories • Thermocouples Wire (J, K, E, and T-Type) • 100 Ohm Platinum RTD PCB General Purpose • 10mV/g, ICP® (IEPE) Accelerometer • PCB Low Noise Coaxial Cable, 10 ft w/10-32 plug to

BNCplug • GRAS General Purpose Array Microphone with BNC

Connector: 50mV/PaNI PS-15 Power Supply, 24 VDC, 5 A, 100-120/200-240 VAC Input 4-Ch, 16-bit,+/-10V Programmable Analog Input Node

• Standard Service Program for CompactRIO Systems

1

2 Structural Analysis Software – ABAQUS (5 users) 1 3 LCD Projector 2

Page 77: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 77 of 81

13. Central Computing Faculty Department :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1 48 Port Layer 2 switch with 

Switching fabric  104 Gbps and  77.4 MPPS, Should have minimum  256 MB DRAM and 256 MB Flash, Switching / Security / QOS must have  1. Support Private Vlan , Vlan Translation, 802.1V, MAC Vlan, 

and VMAN (Q‐in‐Q) 2. Should support policy based traffic redirection and IP 

route compression 3. Should support IPv6 in hardware and software from day 1 4. Should support DHCP Snooping , Trusted DHCP server , 

Packet Anomaly detection, DHCP Secured ARP, GARP protection 

5. Should support flexible traffic analysis with NetFlow or sFlow 

6. Support for IEEE 802.1AS ‐ Timing and Synchronization for Time Sensitive Applications in Bridged Local Area, IEEE 802.1Qav ‐ Forwarding and Queuing Enhancements for Time‐Sensitive Streams 

7. SNMPv3, NTP, HTTPS,  SSHv2, SCP2, SFTP 8. L2 Ping &  L2 trace route, IPv6 telnet and TFTP , LLDP and 

CDP 9. Compliant to MEF 9 and MEF 14 , ASTM D3580 , RoHS 6 , 

CISPR 24 A2:2010 , IEC 61000‐4‐5:2005/EN 61000‐4‐5:2006, UL60950‐1 2ndEd.  

Note:Switch should be compatible with extreme x670g2-48x-q L3 Switch and necessary VLAN configuration should be done to our satisfaction with compatible to Trans-receiver SFP Model No. 10301 SR SFP+ Module of extreme. 

6

2 24 Port Layer 2 switch with Switching fabric  56Gbps and  41.6 MPPS, Should have minimum  256 MB DRAM and 256 MB Flash, Switching / Security / QOS must have above 1‐9 details  Note:Switch should be compatible with extreme x670g2-48x-q L3 Switch and necessary VLAN configuration should be done to our satisfaction with compatible to Trans-receiver SFP Model No. 10301 SR SFP+ Module of extreme.

8

3 IR Dome Bullet Camera(CPPLUS/HIKVSION/DAHUA/CADYCE/AXIS/SAMSUNG or equivalent make) HDCVU Min 2MP,1/2 9:, resolution 25/30 FPS@ 1080P, Low power consumption, True D/N with IR cut filter with 1 a.10A power supply. 2.DVR with 16 channel 2MP HDCVI with 1 Audio channel 3.Hard disk‐2 TB  4.Cabling wit Casing‐capping per meter (3+1)   5. Installation (Comparision will be based on total cost of above system quoted) 

Camera-60

DVR with

HDD-6

Page 78: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 78 of 81

4 Wi Fi link between ccf to quadrangle 150 mbps

5 Wireless equipment to cover all class rooms with proper speed 150 mbps

6 Embedded device with in built 32 GB card& linux os with wireless/blue tooth connectivity between lcd projector& laptop/server at ccf deptt

7 PROJECTOR LAMPS FOR DELL,EPSON LCD PROJECTOR

8 Android Lcd projector instead of lamp LED LAMP

9 42/32 with full hdmi LED TV

10 Ip camera 1.3mega pixle

11 8/12 port nvr

12 Hard Disk for recording 4 Tb

13 Continues power back up facility for wireless camera Batt /solar panel etc

Page 79: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 79 of 81

14. Training and Placement Department :

Item No. Particulars Approx.

Qty

Basic Unit Price

VAT +

Other +LBT

Total

Amount Rs.

EMD amount (3 % of the total amount)

q a b (a+b)*q

1

Access point Dual Band wireless-N, Access point WNDAP360 Wi-Fi, Interface 802.11a\b\g [email protected]/5.0 GHz LAN Interface 10/100/1000 Gigait Ethernet

3

Page 80: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 80 of 81

Terms & Conditions Please note following terms and conditions before filling the tender form and return this sheet duly signed along with company’s seal. 1. Essential additional Services to be included Installation and training on college site.

Supplying documentation, Software Media /Software with media. (Licensed Version), Exclusive Warranty for three years. Equipment for its malfunctioning, if any, must be replaced / repaired within 15 days during warranty period.

2. For any proprietary items, attach certificate from the manufacturer that the product is proprietary and also attach the valid certificate of authorized dealer/distributor/channel partner.

3. Local support for three years must be provided by the party/manufacturer. By default warranty/bank guaranty for 3 years will be applicable for all items mentioned in tender.

4. The name of your principal party (if any) is to be indicated for the items, so as to enable to place the order with the principal.

5. Usual payment terms: 80% against successful installation, testing, training, tagging, satisfactory certification from concerned HOD and 20% after submission of Bank guarantee for three years of 10% of the total purchase order.

6. The tender form is not transferable. 7. The offer value is to be calculated on the basis of Rate x Quantity 8. Tender documents should be sealed in an envelope along with duly signed terms & condition sheet in

the college office on or before 2nd September, 2016 (12:00 noon). Late documents will not be accepted.

9. The cost of the TENDER document is in the form of DD of Rs.1000/-- in favour of Director, Walchand College of Engineering, Sangli. This amount is non refundable. The tender document after having downloaded from the college website, www.walchandsangli.ac.in; is to be filled up by the bidder and the filled tender document is to be submitted along with the D.D. Document without D.D. will not be considered.

10. If the space provided in any one of the columns of the tender form is not enough, additional pages may be attached.

11. Earnest Money Deposit (EMD) is to be calculated as 3% of the offered total price of the items for a department. Separate Demand Drafts for each of the departments must be submitted along with the tender documents. Tender submissions, without Demand Drafts will not be considered. Demand Drafts must be drawn on any Nationalized Bank in favour of `The Director, Walchand College of Engineering, Sangli’ payable at Sangli. If the tender offer is not acceptable, the EMD will be refundable.

12. The right to reject or accept any or all offers with or without modifications from any or all parties without assigning any reason is reserved with the Director, Walchand College of Engineering, Sangli.

13. The bidder has to submit an undertaking for terms and conditions, if selected for placing the order. 14. Rates quoted should be valid at least for Two Months. 15. The supply of materials should be done within two weeks after date of purchase order. 16. Legal matter will be restricted to Sangli jurisdiction. 17. Quantity mentioned in tender for item may vary depending on availability of fund. 18. Enough supporting documents, for example, specifications of the items, customer list, Authorization

letter, Sales tax number letter, etc. must be submitted along with the tender documents.

I / We have read the above instructions carefully, and I /we abide by the instructions.

Seal of Company Authorized Signature Name:

Date:

Page 81: LAST DATE OF RECEIVING TENDER DATE OF OPENING THE … · LAST DATE OF RECEIVING TENDER 2nd September, 2016 up to 12:00 noon DATE OF OPENING THE TENDER 2nd September, 2016 at 3.30

Tender –August 2016

Page 81 of 81

Details of EMD Sr. No.

Department Total Amount

Rs. Ps.

EMD

Rs. Ps

D.D. Details D.D. No. D.D. Date

DD/MM/YYYY

Nationalized Bank’s Name

1 CIVIL 2 MECHANICAL 3 ELECTRICAL 4 ELECTRONICS 5 CSE 6 INFORMATION TECHNOLOGY 7 PHYSICS 8 CHEMISTRY 9 EXAM CELL 10 OFFICE 11 TILAK HALL 12 APPLIED MECH. Seal of Company Authorized Signature Name: Date: For more details for filling up of the tender form, following respective head of the department may be contacted.   Sr. No. 

Name of Department  Contact No.  Email Address 

1  CIVIL  (0233)‐2300230  [email protected] 

2  MECHANICAL (0233)‐2300716  [email protected] 3  ELECTRICAL (0233)‐2300933 [email protected] 4  ELECTRONICS (O233)‐2304470 [email protected]  CSE (0233)‐2301327  [email protected] 6  INFORMATION

TECHNOLOGY (0233)‐2301910 [email protected]

7  PHYSICS 9822319324  [email protected] 8  CHEMISTRY 9423273146 [email protected] 9  EXAM CELL (0233)‐2303307 [email protected]  OFFICE (0233)‐2300383 [email protected] 11  CENTRAL COMPUTING

FACULTY (0233)‐2300410  

[email protected]