lecture23_temperature scales maximum performance measures

22
1 Professor: Euiwon Bae Lecture Hours : MWF 1:30-2:20 in ME1130 Office Hours : MWF 2:30-3:30 in ME1091 Email : [email protected] Phone : 765-494-6849 Course website : http://engineering.purdue.edu/ME200 ME200 : Thermodynamics I Lecture 23 : Temperature scales & maximum performance measures

Upload: euiwon-bae

Post on 18-Apr-2015

130 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Lecture23_Temperature Scales Maximum Performance Measures

1

Professor: Euiwon Bae

Lecture Hours : MWF 1:30-2:20 in ME1130

Office Hours : MWF 2:30-3:30 in ME1091

Email : [email protected]

Phone : 765-494-6849

Course website : http://engineering.purdue.edu/ME200

ME200 : Thermodynamics I

Lecture 23 : Temperature scales &

maximum performance measures

Page 2: Lecture23_Temperature Scales Maximum Performance Measures

2

Outline

The Kelvin and temperature scales

Maximum performance measures for cycles operating

Between Two thermal reservoirs

Examples

Page 3: Lecture23_Temperature Scales Maximum Performance Measures

3

Kelvin scales

From the Carnot corollary:

Hot reservoir

System A

Cold reservoir

Q

Q

W

๐œ‚๐ด

Hot reservoir

System B

Cold reservoir

Q

Q

W

๐œ‚๐ต

TH TH

TC TC

๐œผ๐‘จ ๐œผ๐‘ฉ =

=

=

Page 4: Lecture23_Temperature Scales Maximum Performance Measures

4

Kelvin scales

ฮท = 1 โˆ’๐‘„๐‘œ๐‘ข๐‘ก๐‘„๐‘–๐‘›

Can argue that efficiency for the reversible cycle is the function of (TH, TC)

From the Carnot corollary:

All reversible power cycles with the same two thermal reservoirs

have the same ๐œผ

(Regardless of substance making up the system (air, steam etc))

-> Temperature is the important factor

๐‘„๐‘

๐‘„๐‘•๐‘Ÿ๐‘’๐‘ฃ = ๐‘“(TH, TC)

Page 5: Lecture23_Temperature Scales Maximum Performance Measures

5

Kelvin scales

In Kevlin scale, the ratio of temperature is equal to the amount of heat transfer for an reversible cycle.

Define a Kelvin scales as :

๐‘„๐‘

๐‘„๐‘•๐‘Ÿ๐‘’๐‘ฃ =

๐‘‡๐ถ๐‘‡๐ป

Page 6: Lecture23_Temperature Scales Maximum Performance Measures

6

Maximum performance measures

For power cycles

ฮท๐‘š๐‘Ž๐‘ฅ =๐‘Š๐‘๐‘ฆ๐‘๐‘™๐‘’

๐‘„๐‘–๐‘›= 1 โˆ’

๐‘„๐‘œ๐‘ข๐‘ก

๐‘„๐‘–๐‘› = 1 โˆ’

๐‘‡๐ถ

๐‘‡๐ป

Maximum achievable efficiency between two thermal reservoir : Carnot efficiency

Wcycle

= Qin- Qout

TH

(Hot)

Tc

(Cold)

W=Qin-Qout

Qin System

๐‘„๐‘

๐‘„๐‘•๐‘Ÿ๐‘’๐‘ฃ =

๐‘‡๐ถ๐‘‡๐ป

Qout

Page 7: Lecture23_Temperature Scales Maximum Performance Measures

7

Maximum performance measures

For power cycles with Tc=298 K and

TH

ฮท

ฮท๐‘š๐‘Ž๐‘ฅ= 1 โˆ’๐‘‡๐ถ

๐‘‡๐ป

Rate of efficiency increase Is high at tower TH

Decreasing Tc below certain

level is impractical

Real power plant 40% compared to theoretical max.

ฮท๐‘š๐‘Ž๐‘ฅ= 1 โˆ’๐‘‡๐ถ

๐‘‡๐ป

= 1 โˆ’298

745= 0.6 (60%)

Page 8: Lecture23_Temperature Scales Maximum Performance Measures

8

Maximum performance measures

For power cycles with TH=298 K and

TC

ฮท

TC=TH

ฮท๐‘š๐‘Ž๐‘ฅ= 1 โˆ’๐‘‡๐ถ

๐‘‡๐ป

Rate of efficiency decreases as TC increases

Tc=Th, efficiency is zero

Page 9: Lecture23_Temperature Scales Maximum Performance Measures

9

Maximum performance measures

For Refrigeration and heat pump cycles

Maximum achievable efficiency between two thermal reservoir

๐‘„๐‘

๐‘„๐‘•๐‘Ÿ๐‘’๐‘ฃ =

๐‘‡๐ถ๐‘‡๐ป

Wcycle =

Qout- Qin>0

TH Tc

W=Qout-Qin

Qout Qin System

ฮฒ๐‘š๐‘Ž๐‘ฅ =๐‘„๐‘–๐‘›

(๐‘„๐‘œ๐‘ข๐‘ก;๐‘„๐‘–๐‘›)=

๐‘‡๐‘

๐‘‡๐ป;๐‘‡๐‘; Refrigeration cycle

ฮณ๐‘š๐‘Ž๐‘ฅ =๐‘„๐‘œ๐‘ข๐‘ก

(๐‘„๐‘œ๐‘ข๐‘ก;๐‘„๐‘–๐‘›)=

๐‘‡๐ป๐‘‡๐ป;๐‘‡๐ถ

; Heat pump cycle

Page 10: Lecture23_Temperature Scales Maximum Performance Measures

10

Maximum performance measures

For Refrigeration cycles with TH=298 K and

TC

๐›ฝ ๐›ฝ๐‘š๐‘Ž๐‘ฅ =

1

๐‘‡๐ป๐‘‡๐‘

โˆ’ 1

COP will gradually increase until Tc gets closer to the Th

TH

Page 11: Lecture23_Temperature Scales Maximum Performance Measures

11

Maximum performance measures

For Refrigeration cycles with TL=298 K and

TH

๐›ฝ ๐›ฝ๐‘š๐‘Ž๐‘ฅ =

1

๐‘‡๐ป๐‘‡๐‘

โˆ’ 1

COP will gradually increase when TH is closer to the TL

TL

Page 12: Lecture23_Temperature Scales Maximum Performance Measures

12

Example 1 Power cycle

5.30 An inventor claims to have developed a power cycle operating between TH=1000 K and Tc=250 K that develops net work equal to a multiple of the amount of energy Qc rejected to the cold reservoir โ€“ that is Wcycle=NQc, where all quantities are positive. What is the theoretical maximum N?

Page 13: Lecture23_Temperature Scales Maximum Performance Measures

13

Example 1 Power cycle

Given : TH, TC, W=N Qc

Find : maximum N

System :

TH

(Hot)

Tc

(Cold)

W=Qin-Qout

Qin System

Qout

Sol: ๐œ‚ = ๐‘Š๐‘๐‘ฆ๐‘๐‘™๐‘’

๐‘„๐ป= 1 โˆ’

๐‘„๐‘

๐‘„๐ป= 1 โˆ’

๐‘‡๐‘

๐‘‡๐ป

๐‘Š๐‘๐‘ฆ๐‘๐‘™๐‘’= ๐‘๐‘„๐‘

๐‘๐‘„๐‘

๐‘„๐ปโ‰ค 1 โˆ’

๐‘„๐ถ

๐‘„๐ปโ‡’ ๐‘ 0.25 โ‰ค 1 โˆ’ 0.25 โ‡’ ๐‘ โ‰ค 3

Page 14: Lecture23_Temperature Scales Maximum Performance Measures

14

Example 1 Power cycle

5.38 At steady state, a 750 MV power plant receives energy by heat transfer from the combustion of fuel at an average T of 317 C. The plant discharges energy by heat transfer to a river whose mass flow rate is 1.65x105 kg/s. Upstream of the power plant the T is 17 C. Determine the increase in the T of the river if the thermal efficiency of the power plant is 40%

Page 15: Lecture23_Temperature Scales Maximum Performance Measures

15

Example 1 Power cycle

Given : 750 MW power plant, TH=317 m=1.65x10^5 kg/s

Tup=17, efficiency 0.4

Find : ฮ”T

System :

TH

(Hot)

Tc

(Cold)

W=750 MW

Qin System

Qout

T1=17 C

T2=?

M=1.65e5 kg/s

Assumption : steady state, incompressible flow with constant specific heat

Sol: ๐œ‚ =

๐‘Š๐‘๐‘ฆ๐‘๐‘™๐‘’

๐‘„๐ป= 1 โˆ’

๐‘„๐‘๐‘„๐ป

; ๐‘„๐ป =750

0.4๐‘€๐‘Š = 1875 ๐‘€๐‘Š

๐œ‚ = 1 โˆ’๐‘„๐‘๐‘„๐ป

; ๐‘„๐ถ = 0.6 ๐‘„๐ป = 1125 ๐‘€๐‘Š

Page 16: Lecture23_Temperature Scales Maximum Performance Measures

16

Example 1 Power cycle

๐‘„๐‘ = ๐‘š๐ถ ๐‘‡2 โˆ’ ๐‘‡1 ; ๐‘ค๐‘•๐‘’๐‘Ÿ๐‘’ ๐ถ = 4.2๐‘˜๐ฝ

๐‘˜๐‘” ๐‘˜ ๐‘“๐‘Ÿ๐‘œ๐‘š ๐‘‡๐‘Ž๐‘๐‘™๐‘’ ๐ด โˆ’ 19

Qout

T1=17 C

T2=?

m=1.65e5 kg/s Tc

(Cold)

Heat exchanger; Qcv=m (h2-h1)

๐‘‡2 =๐‘„๐‘๐‘š๐ถ

+ ๐‘‡1 =1125 MW

1.65x105kgs 4.2

๐‘˜๐ฝ๐‘˜๐‘” ๐‘˜

+ 290 ๐พ = 291.62 ๐พ

Page 17: Lecture23_Temperature Scales Maximum Performance Measures

17

Example 2 Refrigeration cycle

5.60 The refrigerator operates at steady state with a COP of 4.5 and a power input of 0.8 kW. Energy is rejected from the refrigerator to the surroundings at 20C by heat transfer from metal coils whose average surface temperature is 28 C. Determine (a) ๐‘„ in KW (b) Lowest theoretical T inside the refrigerator in K (c) Maximum theoretical power in kW that could be developed by a power cycle operating between coils and the surroundings. Would you recommend making use of this opportunity for developing power?

Page 18: Lecture23_Temperature Scales Maximum Performance Measures

18

Example 2

Given : COP 4.5 Win=0.8 kW TH=20 C Tcoil=28 C

Find : Q, Tc, max theoretical power

System :

TH=20C Tc

W=0.8 kW

Qout Qin System

COP=4.5

Tcoil=28C

Sol ฮฒ๐‘š๐‘Ž๐‘ฅ =

๐‘„๐‘–๐‘›๐‘Š๐‘–๐‘›

=๐‘„๐‘–๐‘›

(๐‘„๐‘œ๐‘ข๐‘กโˆ’๐‘„๐‘–๐‘›); ๐‘„๐‘–๐‘› = 3.6 ๐‘˜๐‘Š

๐‘„๐‘œ๐‘ข๐‘ก =ฮฒ โˆ’ 1

ฮฒ๐‘„๐‘–๐‘› = 4.4 ๐‘˜๐‘Š

Page 19: Lecture23_Temperature Scales Maximum Performance Measures

19

Example 2

TH=20C Tc

W=0.8 kW

Qout Qin System

COP=4.5

Tcoil=28C

ฮฒ๐‘š๐‘Ž๐‘ฅ =๐‘„๐‘–๐‘›

(๐‘„๐‘œ๐‘ข๐‘กโˆ’๐‘„๐‘–๐‘›)=

๐‘‡๐‘

๐‘‡๐ป โˆ’ ๐‘‡๐‘;

๐‘ ๐‘œ๐‘™๐‘ฃ๐‘–๐‘›๐‘” ๐‘“๐‘œ๐‘Ÿ ๐‘‡๐‘ =๐‘‡๐ป1

ฮฒ๐‘š๐‘Ž๐‘ฅ

:1= 239.72 ๐พ = โˆ’33 ๐ถ

๐œ‚ = 1 โˆ’๐‘‡๐ถ๐‘‡๐ป

= 1 โˆ’๐‘‡๐ป๐‘‡๐‘๐‘œ๐‘–๐‘™

= 1 โˆ’293

301= 0.0266 = 2.6%

๐œ‚ =๐‘Š๐‘๐‘ฆ๐‘๐‘™๐‘’

๐‘„๐ปโ‰ค 1 โˆ’

๐‘‡๐ถ๐‘‡๐ป

โ‡’ ๐‘Š โ‰ค 0.12 ๐‘˜๐‘Š

Page 20: Lecture23_Temperature Scales Maximum Performance Measures

20

Example 3 Heat pump cycle

5.66 A heat pump with a COP of 3.8 provides energy at an average rate of 75,000 kJ/h to maintain a building at 21 C on a day when the outside temperature is 0 C. If electricity cost is 8 cents per kWh (a) Actual operating cost and the minimum theoretical operating

cost in $/day (b) Compare this with the cost of electrical resistance heating

Page 21: Lecture23_Temperature Scales Maximum Performance Measures

21

Example 3 Heat pump cycle

Given : heat pump to maintain temperature Find : theoretical and actual cost/ cost for using electrical resistance System : W

Qin Qout

ฮณ=3.8

Qout=75000 kJ/h

T=0 C

Tin=21 C

Assumption : electricity cost 8 cent KWH Sol :

Since COP is given ๐‘Š =๐‘„ ๐‘œ๐‘ข๐‘ก

๐›พ=

75000๐‘˜๐ฝ

โ„Ž

3.8= 19737

๐‘˜๐ฝ

โ„Ž

Since 1 KWH=3600 kJ => $0.08 per 3600 kJ Therefore for 24 h work input 19737 kJ/h*24h=473688 kJ => 473688 kJ/3600 kJ*0.08=$10.52

Page 22: Lecture23_Temperature Scales Maximum Performance Measures

22

Example 3 Heat pump cycle

If we need the minimum cost -> when the COP is maximum Using two temperature only

๐›พ๐‘š๐‘Ž๐‘ฅ =๐‘‡๐ป

๐‘‡๐ป โˆ’ ๐‘‡๐ถ=

1

1 โˆ’๐‘‡๐ถ๐‘‡๐ป

= 14

Since COP is given ๐‘Š =๐‘„ ๐‘œ๐‘ข๐‘ก

๐›พ=

75000๐‘˜๐ฝ

โ„Ž

14= 5357

๐‘˜๐ฝ

โ„Ž

Since 1KWH=3600 kJ => $0.08 per 3600 kJ Therefore for 24 h work input 5357 kJ/h*24h=128568kJ => 128568 kJ/3600 kJ*0.08=$2.85

For resistance heating 75000kJ/h/3600*24*0.08=$40/day