led 175w tm 87% over in - led replacement bulbs | hid light … · 2019-03-14 · hylite high...

2
Page: 1 of 2 Lamp can be oriented in any position - does not affect or diminish the life of the Lamp Universal Burning Positioning Incandescent HPS/HID CFL HyLite 275W 175W 100W 36W 87% 79% 64% Energy Savings (%)* * Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%! Replace with 36W HL-OC-36W-E39 4.3” (109mm) 9.5” (242mm) Ø 3.7” (93mm) E39/E40 5.2” (133mm) 1.6” (40mm) 36W HL-OC-36W-E39 100-277V, AC 3.7" (93mm) 3.7" (93mm) Base Down Base Sideways Base Up Designed for easy installation in new and existing fixtures, HyLite LED Omni-Cob Lamps are suitable for a variety of applications. They feature excellent optics for increased visibility, and low power consumption, saving from 70% to 90% on electricity costs. With a lamp life of up to 60,000 hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs. HyLite LED Omni-Cob Lamp enhances vision for better Optical Acuity, reduces Light Pollution, and provides 360° of clean, bright light. Suitable for fully enclosed Fixtures, its compact size makes it the ideal replacement for CFL, MV, HID, and HPS lamps in existing E26/E27 (Medium) and E39/E40 (Mogul) Base Fixtures. • Extremely Efficient: High Lumen Efficacy: 140 LpW • Fully Encapsulated: Shatter-proof, High-Shock & High-Vibration Resistant • Omni-Directional with Optimized Lighting Beam provides Maximum 360° Luminance. Perfect for Post Tops and Low Bays • Bright white light for greater Visibility and Safety. High >80 CRI • Easy Installation: No Ballast necessary. Direct Retrofit into existing socket • Instant Start and Restart: No warm-up time required • Heat & Impact Resistant, UV Protected, Non-yellowing, Optical Grade Lens • Good Heat Dissipation with proprietary-designed Heat Sink • Cool Operation: Does not add to Heat Load while producing brilliant light • Safe and Reliable: Isolated Circuit Design. Integral 1 kV Surge Suppressor & Protection. Includes a Free 20kA in-line Surge Protection Device for added Protection • No Electro-Magnetic (EMi) or Radio Frequency Interference (RFi) • Ingress Protection: IP65. Complete protection against Contact, Dust Infiltration, and Splashed Water • Safe: Contain No Hazardous Materials; RoHS Compliant: No Lead, Mercury, Toxic Metals or Arsenic Gases. No Disposal requirements. Facilitates LEED ® points. • Environmentally Friendly: 98% of the HyLite LED Lamp is Recyclable HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality of Light with Energy Savings of 87% over Incandescent, 79% over HPS / MH Lamps and 64% over CFL. OMNI-COB TM LED 175W MH / HPS Equivalent *Depending upon the ambient temperature of the installation location High Performance LED Omni-Cob Lamp, 36W FREE! 20 kA In-line Surge Protection Device Included. Additional Protection for your HyLite Omni-Cob Lamp at no Cost! NO LEAD, MERCURY, HEAVY METALS OR TOXIC GASES 98% RECYCLABLE LED Product Partner Reliable and Long-Lasting Warranty 5 years Vibration and Shock Resistant Solid State Radiation-Free No Humming IR UV No IR/UV No Noise 140 LpW LM-79 Tested High Efficacy LM-80 Tested ISTMT Tested Reliability Reduction of up to 87% Energy Costs Up to 60,000 Hours Low Voltage Longer Life & For Enclosed Luminaires Suitable 360° Illumination Zero Interference No EMi / RFi Suitable for Damp Locations Enclosed Fixtures

Upload: others

Post on 15-Aug-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LED 175W TM 87% over In - LED Replacement Bulbs | HID Light … · 2019-03-14 · HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality

Page: 1 of 2

Lamp can be oriented in any position - does not affect or diminish the life of the Lamp

Universal Burning Positioning

Incandescent HPS/HID CFL HyLite

275W 175W 100W 36W

87% 79% 64% Energy Savings (%)*

* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!

Replacewith

36WHL-OC-36W-E39

4.3”

(109m

m)

9.5”

(242

mm

)

Ø 3.7” (93mm)

E39/

E40

5.2”

(133m

m)

1.6” (

40m

m)

36WHL-OC-36W-E39

100-277V, AC

3.7" (93mm)

3.7"

(93m

m)

Base Down

Base Sideways

Base Up

Designed for easy installation in new and existing fixtures, HyLite LED Omni-Cob Lamps are suitable for a variety of applications. They feature excellent optics for increased visibility, and low power consumption, saving from 70% to 90% on electricity costs. With a lamp life of up to 60,000 hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs.

HyLite LED Omni-Cob Lamp enhances vision for better Optical Acuity, reduces Light Pollution, and provides 360° of clean, bright light. Suitable for fully enclosed Fixtures, its compact size makes it the ideal replacement for CFL, MV, HID, and HPS lamps in existing E26/E27 (Medium) and E39/E40 (Mogul) Base Fixtures.

• ExtremelyEfficient:HighLumenEfficacy:140LpW

• FullyEncapsulated:Shatter-proof,High-Shock&High-VibrationResistant

• Omni-DirectionalwithOptimizedLightingBeamprovidesMaximum 360° Luminance. Perfect for Post Tops and Low Bays

•BrightwhitelightforgreaterVisibilityandSafety.High>80CRI

• EasyInstallation:NoBallastnecessary.DirectRetrofitintoexistingsocket

•InstantStartandRestart:Nowarm-uptimerequired

• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens

• GoodHeatDissipationwithproprietary-designedHeatSink

• CoolOperation:DoesnotaddtoHeatLoadwhileproducingbrilliantlight

• SafeandReliable:IsolatedCircuitDesign.Integral1kVSurgeSuppressor &Protection.IncludesaFree20kAin-lineSurgeProtectionDevicefor added Protection

•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)

• IngressProtection:IP65.CompleteprotectionagainstContact,Dust Infiltration, and Splashed Water

•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalrequirements. Facilitates LEED® points.

•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable

HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality of Light with Energy Savings of 87%overIncandescent, 79% over HPS / MH Lamps and 64% over CFL. OMNI-COB TM

LED 175WMH / HPSEquivalent

*Depending upon the ambient temperature of the installation location

High Performance LED Omni-Cob Lamp, 36W

FREE!20 kA

In-line Surge Protection Device Included.

Additional Protection for your HyLite

Omni-Cob Lampat no Cost!

NOLEAD, MERCURY, HEAVY METALS

OR TOXIC GASES

98%RECYCLABLE

LED Product Partner

Reliable andLong-Lasting

Warranty

5years

Vibration andShock Resistant

Solid State

Radiation-FreeNo Humming

IRUV

No IR/UV

No Noise

140 LpWLM-79 Tested

High Efficacy

LM-80 TestedISTMT Tested

Reliability

Reduction ofup to 87%

Energy Costs

Up to 60,000 Hours

Low Voltage

Longer Life&

For Enclosed Luminaires

Suitable

360°

IlluminationZero

Interference

No EMi / RFi

Suitable for

Damp Locations Enclosed Fixtures

Page 2: LED 175W TM 87% over In - LED Replacement Bulbs | HID Light … · 2019-03-14 · HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality

Page: 2 of 2

• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)

• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)

• Efficacy:140LpW • CRI:>80 • BeamAngle:360º • Max.THD(%):<15% • UniversalInputVoltage

• PowerFactor:>0.9 • Protection:IP65 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.

• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-50VA-480-277V Spec. Sheet at: https://hyliteledlighting.com/resources/specification-sheets/

• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times

Model Delivered Maximum InputLine Base Dimensions&Weight(each) No. Watts Lumens InstallHeight Current Type Diameter Height Weight

HL-OC-36W-E39 36 5040 <20ft.(6m) 130~360mA E39/E40(Mogul) 3.7”(93mm) 9.5”(242mm) 2lb.(900g)

OMNI-COB TM

LEDAs part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.

High Performance LED Omni-Cob Lamp, 36W

Photometrics

Intensity: (Unit, cd) C0/180C90/270

0° 90° 135°90°135°180° 45°45°

80

20

40

100

60

Intensity: (Unit, cd) C0/180C90/270

135° 150° 165° 180° 165° 150° 135°

45° 30° 15° 0° 15° 30° 45°

60°

120°

105°

90°

75°

60°

120°

105°

90°

75°

100806040

180°

η = 100%

Ideal for high-quality illumination in:

• AreaLighting • ParkingLot • DecorativeLighting

• FloodLighting • AccentLighting • CarriageLanterns

• PendantLights • Driveway&WalkwayLighting • LowBayLighting

• TaskLighting • Historic/VintageFixtures • Stairwells,CorridorsLighting

• JellyJarLights • IndustrialBeacons • PedestrianTunnels

• GlobeFixtures • Explosion-proofFixtures • RailRoadStationPlatforms

• WallPacks • Freezer&ColdStorageLights • Site Lighting

• WallScones • DownLights • Security Lighting

© 2012-2019 HyLite LED, LLC., USA For more information, please visit: https://hyliteledlighting.com/ 031219

Installation: HyLite LED Lamps are designed to work off 100V to 277V, AC. Ballast(ifequipped)mustbebypassedor removed from the fixture before installing the lamp. Eliminating the Ballast saves additional costs related to Maintenance, Energy Consumption and Performance. By-passing Ballast will also ensure that there is no EMi/RF interference. The installer MUST ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.

Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an Electric Shock, or Fire.

Warning - Risk of Fire or Electric Shock

• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will create a Hazardous and Fatal Working Environment.

• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.

• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. This will ensure Lumen Maintenance and extend its Working Life. When products are used in Outdoor Fixtures, ensure the space is Waterproof and Well Ventilated.

• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.

• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.

• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protect the Metal-threaded base of the LED Lamp to prevent Water and/or Moisture Incursion that can lead to Premature Degradation of the Lamp Base and eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.

• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.