led 175w tm 87% over in - led replacement bulbs | hid light … · 2019-03-14 · hylite high...
TRANSCRIPT
Page: 1 of 2
Lamp can be oriented in any position - does not affect or diminish the life of the Lamp
Universal Burning Positioning
Incandescent HPS/HID CFL HyLite
275W 175W 100W 36W
87% 79% 64% Energy Savings (%)*
* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!
Replacewith
36WHL-OC-36W-E39
4.3”
(109m
m)
9.5”
(242
mm
)
Ø 3.7” (93mm)
E39/
E40
5.2”
(133m
m)
1.6” (
40m
m)
36WHL-OC-36W-E39
100-277V, AC
3.7" (93mm)
3.7"
(93m
m)
Base Down
Base Sideways
Base Up
Designed for easy installation in new and existing fixtures, HyLite LED Omni-Cob Lamps are suitable for a variety of applications. They feature excellent optics for increased visibility, and low power consumption, saving from 70% to 90% on electricity costs. With a lamp life of up to 60,000 hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs.
HyLite LED Omni-Cob Lamp enhances vision for better Optical Acuity, reduces Light Pollution, and provides 360° of clean, bright light. Suitable for fully enclosed Fixtures, its compact size makes it the ideal replacement for CFL, MV, HID, and HPS lamps in existing E26/E27 (Medium) and E39/E40 (Mogul) Base Fixtures.
• ExtremelyEfficient:HighLumenEfficacy:140LpW
• FullyEncapsulated:Shatter-proof,High-Shock&High-VibrationResistant
• Omni-DirectionalwithOptimizedLightingBeamprovidesMaximum 360° Luminance. Perfect for Post Tops and Low Bays
•BrightwhitelightforgreaterVisibilityandSafety.High>80CRI
• EasyInstallation:NoBallastnecessary.DirectRetrofitintoexistingsocket
•InstantStartandRestart:Nowarm-uptimerequired
• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens
• GoodHeatDissipationwithproprietary-designedHeatSink
• CoolOperation:DoesnotaddtoHeatLoadwhileproducingbrilliantlight
• SafeandReliable:IsolatedCircuitDesign.Integral1kVSurgeSuppressor &Protection.IncludesaFree20kAin-lineSurgeProtectionDevicefor added Protection
•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)
• IngressProtection:IP65.CompleteprotectionagainstContact,Dust Infiltration, and Splashed Water
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalrequirements. Facilitates LEED® points.
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality of Light with Energy Savings of 87%overIncandescent, 79% over HPS / MH Lamps and 64% over CFL. OMNI-COB TM
LED 175WMH / HPSEquivalent
*Depending upon the ambient temperature of the installation location
High Performance LED Omni-Cob Lamp, 36W
FREE!20 kA
In-line Surge Protection Device Included.
Additional Protection for your HyLite
Omni-Cob Lampat no Cost!
NOLEAD, MERCURY, HEAVY METALS
OR TOXIC GASES
98%RECYCLABLE
LED Product Partner
Reliable andLong-Lasting
Warranty
5years
Vibration andShock Resistant
Solid State
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
140 LpWLM-79 Tested
High Efficacy
LM-80 TestedISTMT Tested
Reliability
Reduction ofup to 87%
Energy Costs
Up to 60,000 Hours
Low Voltage
Longer Life&
For Enclosed Luminaires
Suitable
360°
IlluminationZero
Interference
No EMi / RFi
Suitable for
Damp Locations Enclosed Fixtures
Page: 2 of 2
• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)
• Efficacy:140LpW • CRI:>80 • BeamAngle:360º • Max.THD(%):<15% • UniversalInputVoltage
• PowerFactor:>0.9 • Protection:IP65 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.
• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-50VA-480-277V Spec. Sheet at: https://hyliteledlighting.com/resources/specification-sheets/
• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times
Model Delivered Maximum InputLine Base Dimensions&Weight(each) No. Watts Lumens InstallHeight Current Type Diameter Height Weight
HL-OC-36W-E39 36 5040 <20ft.(6m) 130~360mA E39/E40(Mogul) 3.7”(93mm) 9.5”(242mm) 2lb.(900g)
OMNI-COB TM
LEDAs part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
High Performance LED Omni-Cob Lamp, 36W
Photometrics
Intensity: (Unit, cd) C0/180C90/270
0° 90° 135°90°135°180° 45°45°
80
20
40
100
60
Intensity: (Unit, cd) C0/180C90/270
135° 150° 165° 180° 165° 150° 135°
45° 30° 15° 0° 15° 30° 45°
60°
120°
105°
90°
75°
60°
120°
105°
90°
75°
100806040
180°
η = 100%
Ideal for high-quality illumination in:
• AreaLighting • ParkingLot • DecorativeLighting
• FloodLighting • AccentLighting • CarriageLanterns
• PendantLights • Driveway&WalkwayLighting • LowBayLighting
• TaskLighting • Historic/VintageFixtures • Stairwells,CorridorsLighting
• JellyJarLights • IndustrialBeacons • PedestrianTunnels
• GlobeFixtures • Explosion-proofFixtures • RailRoadStationPlatforms
• WallPacks • Freezer&ColdStorageLights • Site Lighting
• WallScones • DownLights • Security Lighting
© 2012-2019 HyLite LED, LLC., USA For more information, please visit: https://hyliteledlighting.com/ 031219
Installation: HyLite LED Lamps are designed to work off 100V to 277V, AC. Ballast(ifequipped)mustbebypassedor removed from the fixture before installing the lamp. Eliminating the Ballast saves additional costs related to Maintenance, Energy Consumption and Performance. By-passing Ballast will also ensure that there is no EMi/RF interference. The installer MUST ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.
Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an Electric Shock, or Fire.
Warning - Risk of Fire or Electric Shock
• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will create a Hazardous and Fatal Working Environment.
• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. This will ensure Lumen Maintenance and extend its Working Life. When products are used in Outdoor Fixtures, ensure the space is Waterproof and Well Ventilated.
• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protect the Metal-threaded base of the LED Lamp to prevent Water and/or Moisture Incursion that can lead to Premature Degradation of the Lamp Base and eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.