led street light - ecowinsun.com€¦ · led street light. zhejiang winsun ... en 60598-2-3...
TRANSCRIPT
WSA7 series lamps with simple structure and curve line as the main element, through different curvature change
enrich the dynamic. Breakthrough the traditional design concepts with LED modules and combine the
characteristics of the LED, ensure the heat radiation space between the LED modules and the air, which is an
excellent outdoor road luminaires.
STANDARDS
EN 60598-1 Luminaires - General requirements
EN 60598-2-3 Luminaires - Road and street lighting
EN 61347-1 Lamp controlgear - Part 1: General and safety requirements
EN 61347-2-13 Lamp controlgear - Part 2-13 : Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules
EN 55015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting
and similar equipment
EN 61547 Equipment for general lighting purposes - EMC immunity requirements
EN 61000-3-2 Electromagnetic compatibility (EMC) - Part 3-2: Limits - for harmonic current emissions
EN 62471 Photobiological safety of lamps and lamp systems
2002/96/EC Waste Electrical & Electronic Equipment (WEEE)
2011/65/EU Restriction of the use of certain Hazardous Substances in EEE (RoHS)
(EC) No 1907/2006 The Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)
Personalized Configuration
Internal components are configured according to customer requirements, meet the personalized needs.
Flexible Installation
Note: V means Vertical installation, H means horizontal installation.
Port reserved for 3pin, 5pin or 7pin socket, convenient for
Photocell or wireless relays for smart city extension.
LED Driver, standard with Inventronics®,
optional for Philips®, Meanwell®, etc.
LED Modules, standard with Philips Lumiled®
LEDs. Light distribution curve available with IESNA
Type I, Type II, Type III, Type IV, Type VS, etc.
Breather, lamp breather
ensures air balance inside and
outside of the lamp which
improved lamp service life.
2 x Latches Design,
tool free entrance
IP68 Waterproof Cable
Connectors for fast
maintenance work.
Surge Production Device (SPD)
V(+15) V ( 0 ) V(-15)
H(+15) H ( 0 ) H(-15)
Technical Parameters
Internal components are configured according to customer requirements, meet the personalized needs.
Product Code WSA7-80 WSA7-100 WSA7-120 WSA7-150 WSA7-180 WSA7-200 WSA7-240
Power 80W 100W 120W 150W 180W 200W 240W
LED Brand Philips Lumileds® 5050
Driver Brand Inventronics®
Drive Current 700mA/ 860mA/ 1050mA
Input Voltage 100-277V AC, 50/60Hz
Dimming 0-5V, 0-10V,PWM, Timer (optional)
Operating
Temp. -40 ºC to +50 ºC
PF >0.95
THD <15%
Lumens (± 5%) 12,400lm 15,000lm 18,600lm 22,500lm 26,100lm 30,000lm 34,800lm
Luminaire
efficacy (± 5%) >150lm/w >150lm/w >150lm/w >150lm/w >145lm/w >150lm/w >150lm/w
Optic IESNA Type I, Short ; IESNA Type II, Medium; IESNA Type III, Medium; IESNA Type VS, Short
CRI >70
CCT 3000K (Warm White), 4000K (Nature White), 5000K (Pure White), 5700K (Cool White)
Rating IP66, IK10
Material Housing: Die-cast aluminum; Heat sink: Stretched Aluminium Alloy, Lens: PC (UV-proof)
Installation Horizontal and vertical installation for optional; Adjustable tilt angle: 0-10-15º
Accessories
(Optional)
Photocell; 3pin, 5pin or 7pin socket
Shell Color Grey (RAL9022), Black (RAL9005) or White, other RAL colors available on request
L70 at 25 º C 100,000 hours
Certifications CE, ROHS, IEC CB, ISO9001,ISO14001, LM79, LM80
Note: Lumens Efficacy above is based on 4000K/5000K/ 5700K, Luminous Efficacy of 3000K is 5-10% lower than other CCTs
Dimension Data:
Power 80W 100W 120W 150W 180W 200W 240W
“L” length 740mm 740mm 820mm 820mm 820mm 900mm 980mm
Weight 8.4kg 8.4kg 9.6kg 9.6kg 9.6kg 10.8kg 12.1kg
Package Data:
Power 80W 100W 120W 150W 180W 200W 240W
“L” length 830mm 830mm 910mm 910mm 910mm 990mm 1070mm
Weight 9.8kg 9.8kg 11.2kg 11.2kg 11.2kg 12.6kg 14.1kg
Dimming
Dimming functions are supported by optional:
Three in One (1-10V DC or PWM Signal or Resistance)
Output constant current level can be adjusted throughout put cable by connecting a resistance or 1 ~
10Vdc or 10V PWM signal between DIM+ and DIM-.
Please DO NOT connect "DIM-" to "-V ".
- Reference resistance value for output current adjustment (Typical)
Resistance value 10KΩ 20KΩ 30KΩ 40KΩ 50KΩ 60KΩ 70KΩ 80KΩ 90KΩ 100KΩ OPEN
% of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%-108%
- 1-10V dimming function for output current adjustment (Typical)
Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN
% of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%-108%
- 10V PWM signal for output current adjustment (Typical): Frequency range: 100Hz ~ 3KHz
Resistance value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN
% of rated current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%-108%
Time Control Dimming
Time control dimming function is supported by optional - Contact WINSUN for Details
Optical Control
Optical control function is supported by optional
If the fixture with OPTICAL CONTROL function, the Optical Receptacle will be installed on the cover of fixture. See picture
above. Fit the 3pins of Optical Sensor to Optical Receptacle, firmly insert and rotate Optical Sensor to proper position.
(3pins with Optical Sensor are provided by WINSUN directly, 7pins socket can be provided, by wireless relay for smart city
should be outsourcing)
AFTER-SALE SERVICE
Zhejiang Winsun Industry Co., Ltd (“WINSUN”) warrants this WINSUN-branded hardware product against defects in materials
and workmanship under normal use for a period of FIVE (5) YEAR from the date of purchase. WINSUN provides free repair
or replacement within warranty period. WINSUN shall charge against defeats by abnormal storage, usage, connection or
change the structure or any components of the product.
*Damage by thunder stroke over 4KV (L, N to FG) /2KV(L to N) will not covered by warranty based on IEC61000-4-5.