led t8 tube - lightup.com · product information the syhdee led t8 tube is approved by ul (dual...
TRANSCRIPT
Product information
The Syhdee LED T8 Tube is approved by UL (Dual Mode, Type A and Type B) ,CUL,FCC and DLC 4.0. It can operate on electronic ballasts as Type A, or be usedwithout ballasts as Type B. Directly replacement for 17W/24T8 and 32W/48T8
Features
· Plug and Play as Type A, no need rewire.· Or direct AC input as Type B, bypass the existing ballast.
· Energy saving: up to 70% .
· 50,000 Hrs lifetime, 5 years warranty.· UL/CUL/FCC/DLC 4.0 listed.
LED T8 tube
Shenzhen Syhdee Co., Ltd.Address:Room(619-620)T3 B6-A Building T3 Hi-Tech village 011 Gaoxinnan 7thRd Nanshan district ShenZhen, GuangDong 518057 China Tel : +86-13316918221 +86-755-23088266 Fax : +86-755-23122125www.syhdee.com Emial: [email protected]
Huizhou Syhdee Manufactory Co., Ltd.Address:SYHDEE Industrial Park,8 Zonger Rd.,Zhongxingongye Avenue, Shuikou,Huizhou.516055, China Tel : +86-752-5306888 Fax : +86-752-5306899
Electrical and Photometric Characteristics
Input voltage: depends on ballast or AC120-277VOperating frequency: 50/60HZPower factor: ≥ 0.90Ambient temperature range: -20°C ...+45°CTHD: <20%IP Rating: IP20
08≥:IRCBeam angle: >120°Dimmable:Main materials: Color Temp:Base type:
No
3000K,3500K,4000K,4500K,5000KG13
VER#:V1.417-07-07
5YEAR
WARRANTY
* Exceeding maximum ratings for operating temperature and input voltage will reduce expected life time or destroy the product. All data subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
®
fluorescent lamps, it widely been used in commercial buildings,such as supermarket, factories ,hotels ,conference rooms, school ,and office buildings.
High efficiency:110-130LPW.
· Eco-friendly: no UV or IR radiation,mercury free, no flickering
Aluminum housing and PC diffuser
Due to the special conditions of the manufacturing processes of LED,the typical data of technical parameters can only refect statistical figures anddo not necessarily correspond to the actual parameters of each single product which could differ from the typical value.
Switch off mains supply before installing/removing lamp
Use in fully enclosed fixtures may affect life performance
Operation and Maintenance Tips
SpecificationsRate
Wattage Length (ft)
CCT(Kelvin)
Rated Luminous
flux (lm)CRI(%)
Pack Qty (Pcs)
LED T8 tube
10 2 4000K 1576 5208>
12 4 4000K 1824 >80
15 4 4000K 2140 >80
18 4 4000K 2488 >80
20 4 4000K 2672 >80
Maximum overall length (mm) 2ft 4ft
8911885A
B 1205
3121306C
Dimension Diagram
ItemNumber
Beam angleHousing
SYH-X08-AB0610
SYH-X08-AB1212
SYH-X08-AB1218
SYH-X08-AB1220
SYH-X08-AB1215
25
25
25
25
140°
140°
140°
140°
140°
Aluminum + Optical PC
Aluminum + Optical PC
Aluminum + Optical PC
Aluminum + Optical PC
Aluminum + Optical PC
595
Store and use the lamps the same way as standard fluorescent lamps.•
Lamps should be kept free from contamination.••
Good condition of the lamp-holder contacts is important to ensure proper operation of lamp.•
For direct wire please check the provided installation instructions••
Not for use in emergency lighting circuits
(W) (Degree)
* All data are related to the entire product
For technical information of other CCT, please contact our sales representative.
Shenzhen Syhdee Co., Ltd.Address:Room 210,Block 4A,Software industry base,Nanshan district ShenZhen, GuangDong 518057 China Tel : +86-13316918221 +86-755-23088266 Fax : +86-755-23122125www.syhdee.com Emial: [email protected]
Huizhou Syhdee Manufactory Co., Ltd.Address:SYHDEE Industrial Park,8 Zonger Rd.,Zhongxingongye Avenue, Shuikou,Huizhou.516055, China Tel : +86-752-5306888 Fax : +86-752-5306899
Notes: All the ITEM NO are FCC certificated .X may be M/T
Package
Installation Diagram
ItemNumber
SYH-X08-AB0610SYH-X08-AB1212SYH-X08-AB1215SYH-X08-AB1218
Qty/Carton(Pcs)
Net Weight(Kg)
Gross Weight(Kg)
Size of CartonLxWxH (mm)
0221BA-80X-HYS
1. Swich off the power before replacement2. Remove diffuser ( if provided).3.Remove the existing fluorescent lamp 4. Verify the existing ballast is on our ballast list or not.· If led tube can be compatible with existing ballast: · Plug T8 LED tube into lamp holders of existing fixture.· Put on diffuser (if removed in step 2)· Turn on power and check the light distribution.
· If LED tube can’t be work with existing ballast or the ballast is dead: · A qualified electrician needed· Remove the existing ballast and rewire as AC 100-277V input · Put on LED tube into tube lamp holders of existing fixture.· Put on the cover diffuser (if needed)· Turn on the power and check the light distribution.
* Note: the above quantity full a container based on tubes pack In foam holders+outer carton and without pallets.
Pcs in 1*20’ GP
Pcs in 1*40’ HQ
Shenzhen Syhdee Co., Ltd.Address:Room 210,Block 4A,Software industry base,Nanshan district ShenZhen, GuangDong 518057 China Tel : +86-13316918221 +86-755-23088266 Fax : +86-755-23122125www.syhdee.com Emial: [email protected]
Huizhou Syhdee Manufactory Co., Ltd.Address:SYHDEE Industrial Park,8 Zonger Rd.,Zhongxingongye Avenue, Shuikou,Huizhou.516055, China Tel : +86-752-5306888 Fax : +86-752-5306899
5.50625x195x195 562504.30529.86 287001235x195x195 7.8752
2707513825
525252
9.86 287001235x195x195 7.879.86 287001235x195x195 7.87 138259.86 287001235x195x195 7.87 13825
13825
Modifications to the product avoid the Warranty