ledgecircle rf manual - defa · 100% 100% 100% 100% 10% off off off 100% 100% 100% 100% 2 - a...
TRANSCRIPT
1www.defa.com
122577 EN Rev. E04 - 0920
LedgeCircle RF Manual
NB! Pleasefindthemanualinotherlanguages onwww.defa.comorscantheQRcode.
Norsk Svensk
www.defa.com2
RF Radar | MinMaxOff
About the productLedgeCircle®RFisaRadarMinMaxOfffittingwithabuilt-inradiocommunication.ThiscombinationmakesLedgeCircle®RFidealforapplicationslikestairwaysandcorridorswherethelightcanremainofforatareducedlevelwhennooneispresent.
Before your start! - Readtheconnectionandconfigurationinstructionsbeforeyoustartmounting!Thisprocessmay beeasiertodowiththefittingsinfrontofyou. - NotethattheRadarsensormaybetriggeredbymotionontheothersideofdoorsandwindows. Adjustthesensitivity/rangeofsensorsaccordingtotheconditions. - LedgeCircle®RFfittingscommunicateatthe868Mhzfrequency.Telecomantennasusingthe 800Mhzand900Mhzbandsmaycausefittingstobepermanentlyon.Thisismostlikelytooccur atthetopfloorsofbuildingswithornearsuchantennas.
How it worksEachLedgeCircle®RFfittingcanreceiveactivationsignalsfromupto30otherfittingsandbesettorespondeitherbyturningontotheMaxlevel(usually100%)ortotheselectedStandby/Minlevel(10,20,30or50%).Byconfiguringthesensorandcommunicationsettings,aLedgeCircle®RFinstallationmaybesetuptobe-haveinawidevarietyofways,dependingonyourneeds.Seefurtherinstructionsonconnectionandconfigurationinthefollowingsections.
Radar activation - example 1:AllconnectedfittingsreactrespondtoactivationsignalsbyturningONtotheMaxlevel(100%).MinMaxOnOffmode.
100% 100% 100%
- AllfittingsareOFFbydefault. - ThefirstfittingtodetectmotionsendsanactivationsignalandturnsONtotheMaxlevel. - Allconnectedfittingsrespondtotheactivationsignalinthesameway. - Thisensuresthatthelightwillbeonwellaheadofthepersonmovingthroughthebuilding.
3www.defa.com
RF Radar | MinMaxOff
100% 100% 100%
- Asapersonmovesthroughthebuilding,eachfittingdetectsmotionandcontinuestosignalthe otherstostayon. - TheHoldPeriodandsubsequentStandbyPeriod(seeSensorManual)doesnotstartrunning untilnomoreactivationsignalsarereceived. - TheHoldandStandbyPeriodsstartrunningatthesametimeforallconnectedfittings. Thismeansthattheyalsoturnoffatthesametime.
100% 100% 100%
- SinceallconnectedLedgeCircle®RFfittingsdetectmotionforwardactivationsignalstoeachother, theinstallationbehavesinthesamewaynomatterwhichfittingfirstdetectsmotion.
100% 100% 100% Hold Period
10% 10% 10% StandbyPeriod
Off Off Off Off
- TheHoldPeriodstartswhenafterthelastdetection/activationsignalhasbeenreceived.Thelight remainsattheMaxlevelduringthisperiod.OncetheHoldPeriodexpiresthelightgoesdowntothe totheselectedMinlevelfortheStandbyPeriod. - Detectionrange,HoldandStandbyPerioddurationandStandbydimminglevelcanbeconfigured withtheremote.
www.defa.com4
Off Off OffOff
Off Off OffOff
10% Off Off Off
100% 100% 100% 100%
1
Radar activation - example 2:Groupedresponses.ConnectedfittingsrespondeitherbyturningONtotheMaxlevelorbyturningONtotheselectedStandby/Minlevel.MinMaxOffmode.
- AllfittingsintheinstallationareOFFbydefault.- Thefirstconnectedfittingtodetectmotionsends anactivationsignalandturnsontotheMaxlevel.- Fittingsonthesamefloorrespondtothe activationsignalinthesameway.- Thefirstfittingonthefloorsaboveandbelow respondbyturningONtotheselectedStandby/ Minlevel,andtheStandbyPeriodstartsrunning.
Off Off OffOff
100% 100% 100% 100%
10% Off Off Off
100% 100% 100%100%
2- Apersonmovingtothesecondfloorisdetected bythefirstfitting,alreadyattheStandbyMinlevel.- ThefittinggoesfromtheselectedMinlevelto 100%andsendsanactivationsignal.- Fittingsonthesecondfloorrespondbyalso turningONtotheMaxlevel.- Thestairwellfittinginthethirdfloorrespondsby turningONtotheselectedStandbylevel.- ThefittingsinthefirstfloorremainattheMaxlevel forthedurationoftheHoldPeriod.- Notethatwhenthefittingsinthefirstfloorarenot alreadyon(e.g.thepersonisleavingfromthe secondfloor),thestairwellfittingonthefirstfloor willalsorespondbyturningONtotheselected Minlevel.
RF Radar | MinMaxOff
5www.defa.com
Off Off Off Off
100% 100% 100% 100%
10% 10% 10%10%
100% 100% 100% 100%
4- Allfittingsinthefirstfloorturnoffatthesame timewhentheStandbyPeriodexpires,except whentheStandbyPeriodissettoindefinite (MinMaxmode/Eternitysign).- Thefittingsinthesecondfloorgototheselected Standby/MinlevelforthedurationoftheStandby Period.- Detectionrange,HoldandStandbyperiod durationandStandbydimminglevelcanbe configuredwiththeremote.
RF Radar | MinMaxOff
10% 10% 10% 10%
100% 100% 100% 100%
100% 100% 100%100%
10% Off Off Off
3- Asthepersoncontinuestomoveupthestairs,the fittingsonthosefloorsbehaveinthesameway.- WhentheHoldPeriodexpiresforthefittingson thefirstfloor,theyturndowntotheselectedMin levelforthedurationoftheStandbyPeriod.- SinceallconnectedLedgeCircle®RFfittings detectmotionandforwardactivationsignalsto eachother,theinstallationbehavesinthesame waynomatterwhichfittingfirstdetectsmotion.
www.defa.com6
How to set up your installationTosetupyourLedgeCircle®RFinstallation,firstconsiderwherefittingswillbeinstalled,whichfittingsthatshouldobeyeachotherandhowyouwanteachfittingtorespondtoanactivationsignal.YoushouldalsoconsiderwhatdurationstheHoldandStandbyperiodsshouldhave,whatyouwanttheStandbydimming/MinlightleveltobeandwhetheryoushouldadjusttheSensorSensitivityincertainfittingstopreventthemfrombeingtriggeredbymotionbehinddoorsorwindows.
Connection - Setonefittingaside.Thiswillbethefirstfittingthattheotherslearntoobey(Fitting1). - Inturn,pointtheremotetoeachoftheotherfittingsandpressandholdthe“Learn/Erase” buttonontheremote. - WhenthefittingsenterLearn-mode,theywillstarttobeeponcepersecond. - RepeatthisforallfittingsyouwanttoreceiveactivationsignalsfromFitting1. - Eachfittingwillremaininlearnmodefor3minutes,unlessmanuallycancelled. - Now,pointtheremotetotheFitting1andpress“Transmit”. - ThefittingsinLearn-modewillconfirmthatthepairinghasbeenestablishedbybeepingrapidly 3times.TheywillnowallrespondtoactivationsignalsfromFitting1. - Tointerconnectallfittings,nowpointtheremotetoFitting1andpressandholdthe“Learn/Erase” buttonuntilitentersLearn-mode. - Placefittingsthathavecompletedthe"Transmit"tooneside,apartfromthosewhohavenot. - Nowselectanotherfitting(Fitting2)andtakeitoutofLearn-modebypointingtheremotetoitand pressingthe“Learn/Erase”button. - PointtheremotetoFitting2againandpress“Transmit”. - Asbefore,allfittingsinlearnmodewillbeeprapidly3timestoconfirmthatthepairingissuccessful. - Repeatabovestepsuntilallfittingshavelearnttorespondtoactivationsignalsfromallotherfittings.
Selecting responses - ResponsesareselectedwiththeRX100%andRXSTBY%buttonsontheremote. - ByselectingRXSTBY%thefittingwillgotoyourselectedStandbydimming/Minlevelwhenactivated. - ThisalsomeansthatthefittingwillgostraighttotheStandbyPeriod.OnceyourselectedStandby Perioddurationexpires,thefittingwillturnOFF. - Pointtheremotetoeachfittingandpressthebuttoncorrespondingwithyourpreferredresponse. - ThefactorysettingforLedgeCircle®RFfittingsisRXSTBY%.
Mounting - NOTE!Pleasereadthesensorandconfigurationinstructionsbeforemounting. - Beawarethateachfittingasamaximumindoorcommunicationrangeof30meters. - Forinstructions,seetheseparatemountingmanualprovidedwitheachfitting.
RF Radar | MinMaxOff
Using the Remote Control, follow the procedure described below:
TheRotarySwitchislocatedinsidethefitting
RF grouping via Rotary SwitchByselectingthesamechannelontheRotaryswitchforallfittingsinapreferredgroupthegroupingisautomaticallycompleted.Useascrewdrivertopointthearrowtotheselectedchannel.
Connect fittings, select responsesTomakethesetupandconnectionprocedureasefficientaspossible,placethefittingsyouwishtoconnectinfrontofyou.
7www.defa.com
Remote Control | RF Wireless
Description TheHRC-11providesafastandeasywaytocustomizeLedgeCircle®RFfittings.Alterthesettingsusingthefunctionsasdescribedbelow.Thefixturewillemitabeepwhenanewsettinghasbeenreceived.
Permanent On/Off functionPress“ON/OFF”toselectpermanentONorpermanentOFFmode.Press“AUTO”,“RESET”toquitthismode.
Auto ModePress“AUTO”toinitiateautomaticmode.Inthismodethesensorandfittingbehaveaccordingtoyourselectedsettings.
Reset functionPress“RESET”,torestoredefaultsettings.
Shift +ThisfeatureisnotavailablewithLedgeCircle® RF fittings.
Power outputPress"Power80%"toreducepowerinputto80%.Thiscanbedoneduringthefirstyearorthefirst10,000hoursofuse,whenthelightoutputisusuallyabovetherequiredamount.Notethatfittingsmustbereturnedto100%manually(withtheremote).
Scene programming1. Press“Start”tobeginprogramming.2. Chooseyoursettingsforthescenewiththeappropriatebuttons.3. Press“Memory”tosavethecreatedsceneintheremotecontrol.4. Press“Apply”tousethesceneineachfitting.
ShiftPress"shift"tousesecondarybuttonvaluesmarkedinred."Shift-mode"isactivefor20seconds.
Brightness +/-UsethesebuttonstoadjustthelightOutputduringtheHoldPeriod.
www.defa.com8
Standby Period (Standby Time)Usethesebuttons(+Shiftforredvalues)tosettheStandbyPeriodto0s/10s/1min/5min/10min/30min/1h/+.Use"0s"tosetthefittingstoOn/Offmode(noStandbyPeriod).Use("+")tosetthefittingstoMinMaxmode.ThefittingwillremainattheselectedMinlevelindefinitely.
Hold Period (Hold Time)UsethesebuttonstosettheHoldTimeto2s/30s/1min/5min/10min/15min/20min/30min.TosetHoldTimeto30s/5min/15min/30min,pressthe“Shift”buttonfirst.
Standby dimming levelSettheStandbydimming/Minlevelto10%/20%/30%/50%.
Remote Control | RF Wireless
Dual Tech & RF modeUsetheLearn/EraseandTransmitbuttonssetupconnectionsbetweenfittings,see"Howtosetupyourinstallation"onpage6.UseRX100%AndRXSTBY%toselectwhetherthefittingshouldgoto100%ortotheselectedStandbylightlevelviaradiocommunication.
Factory settings:-Sensitivity: 100%-Holdperiod: 1min.-Standbyperiod: 5min.-Standbydimlevel: 20%-Daylightthreshold: Disable
Detection range Pressthesebuttonstosetdetectionrangeto100%/75%/50%/10%.