ledgecircle rf manual - defa · 100% 100% 100% 100% 10% off off off 100% 100% 100% 100% 2 - a...

8
www.defa.com 122577 EN Rev. E04 - 0920 LedgeCircle RF Manual NB! Please find the manual in other languages on www.defa.com or scan the QR code. Norsk Svensk

Upload: others

Post on 17-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

1www.defa.com

122577 EN Rev. E04 - 0920

LedgeCircle RF Manual

NB! Pleasefindthemanualinotherlanguages onwww.defa.comorscantheQRcode.

Norsk Svensk

Page 2: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

www.defa.com2

RF Radar | MinMaxOff

About the productLedgeCircle®RFisaRadarMinMaxOfffittingwithabuilt-inradiocommunication.ThiscombinationmakesLedgeCircle®RFidealforapplicationslikestairwaysandcorridorswherethelightcanremainofforatareducedlevelwhennooneispresent.

Before your start! - Readtheconnectionandconfigurationinstructionsbeforeyoustartmounting!Thisprocessmay beeasiertodowiththefittingsinfrontofyou. - NotethattheRadarsensormaybetriggeredbymotionontheothersideofdoorsandwindows. Adjustthesensitivity/rangeofsensorsaccordingtotheconditions. - LedgeCircle®RFfittingscommunicateatthe868Mhzfrequency.Telecomantennasusingthe 800Mhzand900Mhzbandsmaycausefittingstobepermanentlyon.Thisismostlikelytooccur atthetopfloorsofbuildingswithornearsuchantennas.

How it worksEachLedgeCircle®RFfittingcanreceiveactivationsignalsfromupto30otherfittingsandbesettorespondeitherbyturningontotheMaxlevel(usually100%)ortotheselectedStandby/Minlevel(10,20,30or50%).Byconfiguringthesensorandcommunicationsettings,aLedgeCircle®RFinstallationmaybesetuptobe-haveinawidevarietyofways,dependingonyourneeds.Seefurtherinstructionsonconnectionandconfigurationinthefollowingsections.

Radar activation - example 1:AllconnectedfittingsreactrespondtoactivationsignalsbyturningONtotheMaxlevel(100%).MinMaxOnOffmode.

100% 100% 100%

- AllfittingsareOFFbydefault. - ThefirstfittingtodetectmotionsendsanactivationsignalandturnsONtotheMaxlevel. - Allconnectedfittingsrespondtotheactivationsignalinthesameway. - Thisensuresthatthelightwillbeonwellaheadofthepersonmovingthroughthebuilding.

Page 3: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

3www.defa.com

RF Radar | MinMaxOff

100% 100% 100%

- Asapersonmovesthroughthebuilding,eachfittingdetectsmotionandcontinuestosignalthe otherstostayon. - TheHoldPeriodandsubsequentStandbyPeriod(seeSensorManual)doesnotstartrunning untilnomoreactivationsignalsarereceived. - TheHoldandStandbyPeriodsstartrunningatthesametimeforallconnectedfittings. Thismeansthattheyalsoturnoffatthesametime.

100% 100% 100%

- SinceallconnectedLedgeCircle®RFfittingsdetectmotionforwardactivationsignalstoeachother, theinstallationbehavesinthesamewaynomatterwhichfittingfirstdetectsmotion.

100% 100% 100% Hold Period

10% 10% 10% StandbyPeriod

Off Off Off Off

- TheHoldPeriodstartswhenafterthelastdetection/activationsignalhasbeenreceived.Thelight remainsattheMaxlevelduringthisperiod.OncetheHoldPeriodexpiresthelightgoesdowntothe totheselectedMinlevelfortheStandbyPeriod. - Detectionrange,HoldandStandbyPerioddurationandStandbydimminglevelcanbeconfigured withtheremote.

Page 4: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

www.defa.com4

Off Off OffOff

Off Off OffOff

10% Off Off Off

100% 100% 100% 100%

1

Radar activation - example 2:Groupedresponses.ConnectedfittingsrespondeitherbyturningONtotheMaxlevelorbyturningONtotheselectedStandby/Minlevel.MinMaxOffmode.

- AllfittingsintheinstallationareOFFbydefault.- Thefirstconnectedfittingtodetectmotionsends anactivationsignalandturnsontotheMaxlevel.- Fittingsonthesamefloorrespondtothe activationsignalinthesameway.- Thefirstfittingonthefloorsaboveandbelow respondbyturningONtotheselectedStandby/ Minlevel,andtheStandbyPeriodstartsrunning.

Off Off OffOff

100% 100% 100% 100%

10% Off Off Off

100% 100% 100%100%

2- Apersonmovingtothesecondfloorisdetected bythefirstfitting,alreadyattheStandbyMinlevel.- ThefittinggoesfromtheselectedMinlevelto 100%andsendsanactivationsignal.- Fittingsonthesecondfloorrespondbyalso turningONtotheMaxlevel.- Thestairwellfittinginthethirdfloorrespondsby turningONtotheselectedStandbylevel.- ThefittingsinthefirstfloorremainattheMaxlevel forthedurationoftheHoldPeriod.- Notethatwhenthefittingsinthefirstfloorarenot alreadyon(e.g.thepersonisleavingfromthe secondfloor),thestairwellfittingonthefirstfloor willalsorespondbyturningONtotheselected Minlevel.

RF Radar | MinMaxOff

Page 5: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

5www.defa.com

Off Off Off Off

100% 100% 100% 100%

10% 10% 10%10%

100% 100% 100% 100%

4- Allfittingsinthefirstfloorturnoffatthesame timewhentheStandbyPeriodexpires,except whentheStandbyPeriodissettoindefinite (MinMaxmode/Eternitysign).- Thefittingsinthesecondfloorgototheselected Standby/MinlevelforthedurationoftheStandby Period.- Detectionrange,HoldandStandbyperiod durationandStandbydimminglevelcanbe configuredwiththeremote.

RF Radar | MinMaxOff

10% 10% 10% 10%

100% 100% 100% 100%

100% 100% 100%100%

10% Off Off Off

3- Asthepersoncontinuestomoveupthestairs,the fittingsonthosefloorsbehaveinthesameway.- WhentheHoldPeriodexpiresforthefittingson thefirstfloor,theyturndowntotheselectedMin levelforthedurationoftheStandbyPeriod.- SinceallconnectedLedgeCircle®RFfittings detectmotionandforwardactivationsignalsto eachother,theinstallationbehavesinthesame waynomatterwhichfittingfirstdetectsmotion.

Page 6: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

www.defa.com6

How to set up your installationTosetupyourLedgeCircle®RFinstallation,firstconsiderwherefittingswillbeinstalled,whichfittingsthatshouldobeyeachotherandhowyouwanteachfittingtorespondtoanactivationsignal.YoushouldalsoconsiderwhatdurationstheHoldandStandbyperiodsshouldhave,whatyouwanttheStandbydimming/MinlightleveltobeandwhetheryoushouldadjusttheSensorSensitivityincertainfittingstopreventthemfrombeingtriggeredbymotionbehinddoorsorwindows.

Connection - Setonefittingaside.Thiswillbethefirstfittingthattheotherslearntoobey(Fitting1). - Inturn,pointtheremotetoeachoftheotherfittingsandpressandholdthe“Learn/Erase” buttonontheremote. - WhenthefittingsenterLearn-mode,theywillstarttobeeponcepersecond. - RepeatthisforallfittingsyouwanttoreceiveactivationsignalsfromFitting1. - Eachfittingwillremaininlearnmodefor3minutes,unlessmanuallycancelled. - Now,pointtheremotetotheFitting1andpress“Transmit”. - ThefittingsinLearn-modewillconfirmthatthepairinghasbeenestablishedbybeepingrapidly 3times.TheywillnowallrespondtoactivationsignalsfromFitting1. - Tointerconnectallfittings,nowpointtheremotetoFitting1andpressandholdthe“Learn/Erase” buttonuntilitentersLearn-mode. - Placefittingsthathavecompletedthe"Transmit"tooneside,apartfromthosewhohavenot. - Nowselectanotherfitting(Fitting2)andtakeitoutofLearn-modebypointingtheremotetoitand pressingthe“Learn/Erase”button. - PointtheremotetoFitting2againandpress“Transmit”. - Asbefore,allfittingsinlearnmodewillbeeprapidly3timestoconfirmthatthepairingissuccessful. - Repeatabovestepsuntilallfittingshavelearnttorespondtoactivationsignalsfromallotherfittings.

Selecting responses - ResponsesareselectedwiththeRX100%andRXSTBY%buttonsontheremote. - ByselectingRXSTBY%thefittingwillgotoyourselectedStandbydimming/Minlevelwhenactivated. - ThisalsomeansthatthefittingwillgostraighttotheStandbyPeriod.OnceyourselectedStandby Perioddurationexpires,thefittingwillturnOFF. - Pointtheremotetoeachfittingandpressthebuttoncorrespondingwithyourpreferredresponse. - ThefactorysettingforLedgeCircle®RFfittingsisRXSTBY%.

Mounting - NOTE!Pleasereadthesensorandconfigurationinstructionsbeforemounting. - Beawarethateachfittingasamaximumindoorcommunicationrangeof30meters. - Forinstructions,seetheseparatemountingmanualprovidedwitheachfitting.

RF Radar | MinMaxOff

Using the Remote Control, follow the procedure described below:

TheRotarySwitchislocatedinsidethefitting

RF grouping via Rotary SwitchByselectingthesamechannelontheRotaryswitchforallfittingsinapreferredgroupthegroupingisautomaticallycompleted.Useascrewdrivertopointthearrowtotheselectedchannel.

Connect fittings, select responsesTomakethesetupandconnectionprocedureasefficientaspossible,placethefittingsyouwishtoconnectinfrontofyou.

Page 7: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

7www.defa.com

Remote Control | RF Wireless

Description TheHRC-11providesafastandeasywaytocustomizeLedgeCircle®RFfittings.Alterthesettingsusingthefunctionsasdescribedbelow.Thefixturewillemitabeepwhenanewsettinghasbeenreceived.

Permanent On/Off functionPress“ON/OFF”toselectpermanentONorpermanentOFFmode.Press“AUTO”,“RESET”toquitthismode.

Auto ModePress“AUTO”toinitiateautomaticmode.Inthismodethesensorandfittingbehaveaccordingtoyourselectedsettings.

Reset functionPress“RESET”,torestoredefaultsettings.

Shift +ThisfeatureisnotavailablewithLedgeCircle® RF fittings.

Power outputPress"Power80%"toreducepowerinputto80%.Thiscanbedoneduringthefirstyearorthefirst10,000hoursofuse,whenthelightoutputisusuallyabovetherequiredamount.Notethatfittingsmustbereturnedto100%manually(withtheremote).

Scene programming1. Press“Start”tobeginprogramming.2. Chooseyoursettingsforthescenewiththeappropriatebuttons.3. Press“Memory”tosavethecreatedsceneintheremotecontrol.4. Press“Apply”tousethesceneineachfitting.

ShiftPress"shift"tousesecondarybuttonvaluesmarkedinred."Shift-mode"isactivefor20seconds.

Brightness +/-UsethesebuttonstoadjustthelightOutputduringtheHoldPeriod.

Page 8: LedgeCircle RF Manual - DEFA · 100% 100% 100% 100% 10% Off Off Off 100% 100% 100% 100% 2 - A person moving to the second floor is detected by the first fitting, already at the Standby

www.defa.com8

Standby Period (Standby Time)Usethesebuttons(+Shiftforredvalues)tosettheStandbyPeriodto0s/10s/1min/5min/10min/30min/1h/+.Use"0s"tosetthefittingstoOn/Offmode(noStandbyPeriod).Use("+")tosetthefittingstoMinMaxmode.ThefittingwillremainattheselectedMinlevelindefinitely.

Hold Period (Hold Time)UsethesebuttonstosettheHoldTimeto2s/30s/1min/5min/10min/15min/20min/30min.TosetHoldTimeto30s/5min/15min/30min,pressthe“Shift”buttonfirst.

Standby dimming levelSettheStandbydimming/Minlevelto10%/20%/30%/50%.

Remote Control | RF Wireless

Dual Tech & RF modeUsetheLearn/EraseandTransmitbuttonssetupconnectionsbetweenfittings,see"Howtosetupyourinstallation"onpage6.UseRX100%AndRXSTBY%toselectwhetherthefittingshouldgoto100%ortotheselectedStandbylightlevelviaradiocommunication.

Factory settings:-Sensitivity: 100%-Holdperiod: 1min.-Standbyperiod: 5min.-Standbydimlevel: 20%-Daylightthreshold: Disable

Detection range Pressthesebuttonstosetdetectionrangeto100%/75%/50%/10%.