level 1 level 2 level 3 level 5 level 4 level 6 level 7 ... links... · mixing system mix pond /...

101
GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Rules Summary LEVEL 6 LEVEL 7 Asset Asset # Network refers to either water or sewerage and refers to all infrastructure owned by GRC within either the collective water or sewerage networks Proposed abbrev key Identifies individual pump station, or treatment plant facility, buried infrastructure sub-system. Proposed abbrev key A facility typically refers to pump stations, treatment plants, water quality stations. Sub- systems refer to buried infrastructure and appurtenances within a service area or catchment. Proposed abbrev key Describes the facility/sub-system process or functional asset grouping. Proposed abbrev key Asset Level 1 describes the asset within the facility/sub-system process or functional asset grouping, often referred to as the parent level Proposed abbrev key Asset Level 2 describes the maintenance managed item level. For example, the pump, and the pump motor, and in some instances the impeller. Asset Level 3: Components can be added to address maintenance managed items such as pump impellers. Activated Carbon Dosing CDACC Access Lid ACLID ACCESSCOVERTYPE Water W 1770 1770 Treatment Plant TP_catchment Air Scour System Elec AIRELEC Active Fire Alarm System FALRM FIREALARMTYPE Wastewater WW Agnes Water AW Pump Station PS_catchment Air Scour System General AIRS Actuator ACTU ACTUATORTYPE Recycled Water RW Benaraby BEN Collection COLL_catchment Air Scour System Mech AIRMECH Aerator AERA AERATORTYPE Bulk Water BW Bororen BOR Air Scour System Pipework AIRPVA Auger AUG AUGERTYPE Boyne Island BI Storage STOR_catchment Alum Dosing CDALM Auto Sampler SAMP SAMPLERTYPE Store ST Calliope CAL Disposal DISP A-Recycle BIOAREC Aviation Lighting AVRLT LIGHTTYPE Curtis Island CI Reservoir RESEV_catchment Backwash System General BACKS Battery BATT BATTERYTYPE Gladstone GLA Reticulation Backwash System Pipework BACKPVA Battery Charging Unit CHAR BATTERYCHARGERTYPE Miriam Vale MV Transmission NET_catchment Backwash System Pump BACKPMP Belt Press BELT PRESSTYPE Mount Larcom ML Distribution Balance Tank and associated Equipment ISTO Bin Hopper BIN BINHOPPERTYPE Tannum Sands TS Bioreactor Aerobic Zone BIOAER Blower BLO BLOWERTYPE Wurdong WUR Bioreactor Anaerobic Zone BIOANE Bore BORE BORETYPE Yarwun YAR Bioreactor Anoxic Zone BIOANO Building BLD BUILDFUNCT Bioreactor Inlet Pipe work BIOIPVA Cable CAB CABLEUSE Bioreactor Scum Management BIOSCM Cathodic Protection CATHP CATHODICTYPE Rotables ROT Bioreactor Structure BIOREAC Centrifuge CENT CENTIFUGETYPE Blowers BIOBLO Chain and Flight System CHAIN CHAINFLIGHTTYPE Bores RBORE Chemical Feed System FEED FEEDERTYPE Communications COM Buildings and Grounds BG Compactor CMPA Bypass System BYPAS Compressor COMP COMPRESSORTYPE Chemical Dosing Systems General CDS Controller CONT CONTOLLERTYPE Combined Rising Main CRSEW Conveyor CONY CONVEYORTYPE Disinfection System DISS Crane CRNE CRANETYPE Disposal Balance Tank DISBTNK Dryer DRYR DRYERTYPE Disposal Irrigation System DISIRR Electronic Data Capture EDC Disposal Outfall DISOUTF Emergency Storage EMS EMSTYPE Disposal System Pipework and Valves DISPVA Fan FAN FANTYPE Effluent System EFFL Fence FENC FENCETYPE Emergency Storage System IEMS Filter FILT FILTERTYPE Ferric Chloride Dosing CDFECL Fire Fighting Equipment FIREQ FIRETYPE Filter Disc System FILDS Fittings FITT FITTINGTYPE Filter Pressure Sand Pumping System FILPSPMP Fuel Storage System FULST Filter Pressure Sand System Pipework FILPSPVA Gear Box GBOX Filtration Pressure Sand System FILPS Generator Set GSET GENERATORTYPE Flocculator Pipework and Valves FLOCPVA Gravity Sewers GSEW SEWERTYPE Flocculator Rapid Mix System FLOMIX Grinder GRND Store Rotables Flocculator Tanks and Structures FLOCHOS Grit Removal GITR GRITCHAMBERTYPE Fluoridation System FLUS Guide Rail GRAIL Gas Pipework UGASPVA Heating Ventilation and Air-Conditioning HVAC HVACTYPE Influent Grit Removal IGTR Human Interface Terminal HITS Influent Dosing with chemical n ICDn Hydrant HYDN HYDRANTTYPE Influent Pipework IPVA Injector INJET INJECTORTYPE Influent Pumping Station IPS Instrument INST INSTRUMENTTYPE Influent Screening ISCR Ladders LADD LADDERTYPE Influent System ISYS Landscaping LANS LANDSCAPETYPE Inlet Aeration System INAIR Lighting Systems LIGT LIGHTTYPE Inlet Channel ICHAN Lightning Protection Systems LTRPROT Inlet Filtration System INFILT Lime Slacker SLAK Inlet Housing INHOU Liner Systems LNR LINERTYPE Inlet Intake Systems ININLT Maintenance Access / Manholes ACMH MANHOLETYPE Inlet Pipework and Valves INPVA Material Protection System MATPROT PROTECTIONTYPE Inlet Surge System INSUR Media MEDR MEDIATYPE Inlet System INLT Meters MET METERTYPE Inlet Water Balance Storage INSTO Mixer MXR MIXERTYPE Inlet Water Pumping System INPMP Motor MOTR MOTORTYPE Lime Dosing CDLIM Motor Control Centre MCC Lime Dosing PCDLIM Node NODE NODETYPE Lime or Acid system PHS Pipe Segment PIPSGM Manholes ACMH Pipes PIPE PIPETYPE Refers to Depot sites or coordinated Storage sites for Spare Equipment that is not placed within any part of the relevant network Term used to describe assets that are 'rotated' in and out of a location,facility or role. For example, there may be a store of submersble pumps that are rotated in and out of sewer pumpstations with a rebuild after each rotation. Asset LEVEL 5 LEVEL 1 LEVEL 2 LEVEL 3 Network Scheme Name Facility/Sub-System Group General Note: The asset level 2 will comprise the individual entries which will be arranged by type where that is of value, otherwise it is the level 3 where the items are listed such as sensor glass, valve spindle etc. NOTE: There is a summary tab for these assets that lists summary and position details of facilities To be finalised LEVEL 4 Function/Process 28/05/2014 1 of 101 Version: 2, Version Date: 09/10/2019 Document Set ID: 4473385

Upload: others

Post on 28-Jun-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Rules Summary

LEVEL 6 LEVEL 7Asset Asset #

Network refers to either water or sewerage and

refers to all infrastructure owned by GRC within

either the collective water or sewerage networks

Prop

osed

abb

rev

key

Identifies individual pump station, or treatment plant

facility, buried infrastructure sub-system.

Prop

osed

abb

rev

key

A facility typically refers to pump stations, treatment plants, water quality stations. Sub-

systems refer to buried infrastructure and

appurtenances within a service area or catchment.

Prop

osed

abb

rev

key

Describes the facility/sub-system process or functional asset grouping.

Prop

osed

abb

rev

key

Asset Level 1 describes the asset within the facility/sub-system process or functional asset grouping, often referred to as the

parent level

Prop

osed

abb

rev

key Asset Level 2 describes the

maintenance managed item level. For example, the

pump, and the pump motor, and in some instances the

impeller.

Asset Level 3: Components can be

added to address maintenance managed

items such as pump impellers.

Activated Carbon Dosing CDACC Access Lid ACLID ACCESSCOVERTYPEWater W 1770 1770 Treatment Plant TP_catchment Air Scour System Elec AIRELEC Active Fire Alarm System FALRM FIREALARMTYPEWastewater WW Agnes Water AW Pump Station PS_catchment Air Scour System General AIRS Actuator ACTU ACTUATORTYPERecycled Water RW Benaraby BEN Collection COLL_catchment Air Scour System Mech AIRMECH Aerator AERA AERATORTYPEBulk Water BW Bororen BOR Air Scour System Pipework AIRPVA Auger AUG AUGERTYPE

Boyne Island BI Storage STOR_catchment Alum Dosing CDALM Auto Sampler SAMP SAMPLERTYPEStore ST Calliope CAL Disposal DISP A-Recycle BIOAREC Aviation Lighting AVRLT LIGHTTYPE

Curtis Island CI Reservoir RESEV_catchment Backwash System General BACKS Battery BATT BATTERYTYPEGladstone GLA Reticulation Backwash System Pipework BACKPVA Battery Charging Unit CHAR BATTERYCHARGERTYPEMiriam Vale MV Transmission NET_catchment Backwash System Pump BACKPMP Belt Press BELT PRESSTYPEMount Larcom ML Distribution Balance Tank and associated Equipment ISTO Bin Hopper BIN BINHOPPERTYPETannum Sands TS Bioreactor Aerobic Zone BIOAER Blower BLO BLOWERTYPEWurdong WUR Bioreactor Anaerobic Zone BIOANE Bore BORE BORETYPEYarwun YAR Bioreactor Anoxic Zone BIOANO Building BLD BUILDFUNCT

Bioreactor Inlet Pipe work BIOIPVA Cable CAB CABLEUSEBioreactor Scum Management BIOSCM Cathodic Protection CATHP CATHODICTYPE

Rotables ROT Bioreactor Structure BIOREAC Centrifuge CENT CENTIFUGETYPEBlowers BIOBLO Chain and Flight System CHAIN CHAINFLIGHTTYPEBores RBORE Chemical Feed System FEED FEEDERTYPE

Communications COM Buildings and Grounds BG Compactor CMPABypass System BYPAS Compressor COMP COMPRESSORTYPEChemical Dosing Systems General CDS Controller CONT CONTOLLERTYPE Combined Rising Main CRSEW Conveyor CONY CONVEYORTYPE Disinfection System DISS Crane CRNE CRANETYPE Disposal Balance Tank DISBTNK Dryer DRYR DRYERTYPE Disposal Irrigation System DISIRR Electronic Data Capture EDCDisposal Outfall DISOUTF Emergency Storage EMS EMSTYPE Disposal System Pipework and Valves DISPVA Fan FAN FANTYPE Effluent System EFFL Fence FENC FENCETYPE Emergency Storage System IEMS Filter FILT FILTERTYPE Ferric Chloride Dosing CDFECL Fire Fighting Equipment FIREQ FIRETYPE Filter Disc System FILDS Fittings FITT FITTINGTYPE Filter Pressure Sand Pumping System FILPSPMP Fuel Storage System FULSTFilter Pressure Sand System Pipework FILPSPVA Gear Box GBOXFiltration Pressure Sand System FILPS Generator Set GSET GENERATORTYPE Flocculator Pipework and Valves FLOCPVA Gravity Sewers GSEW SEWERTYPE Flocculator Rapid Mix System FLOMIX Grinder GRND

Store Rotables Flocculator Tanks and Structures FLOCHOS Grit Removal GITR GRITCHAMBERTYPE Fluoridation System FLUS Guide Rail GRAILGas Pipework UGASPVA Heating Ventilation and Air-Conditioning HVAC HVACTYPE Influent Grit Removal IGTR Human Interface Terminal HITSInfluent Dosing with chemical n ICDn Hydrant HYDN HYDRANTTYPE Influent Pipework IPVA Injector INJET INJECTORTYPE Influent Pumping Station IPS Instrument INST INSTRUMENTTYPEInfluent Screening ISCR Ladders LADD LADDERTYPE Influent System ISYS Landscaping LANS LANDSCAPETYPE Inlet Aeration System INAIR Lighting Systems LIGT LIGHTTYPE Inlet Channel ICHAN Lightning Protection Systems LTRPROTInlet Filtration System INFILT Lime Slacker SLAKInlet Housing INHOU Liner Systems LNR LINERTYPE Inlet Intake Systems ININLT Maintenance Access / Manholes ACMH MANHOLETYPE Inlet Pipework and Valves INPVA Material Protection System MATPROT PROTECTIONTYPE Inlet Surge System INSUR Media MEDR MEDIATYPE Inlet System INLT Meters MET METERTYPE Inlet Water Balance Storage INSTO Mixer MXR MIXERTYPE Inlet Water Pumping System INPMP Motor MOTR MOTORTYPE Lime Dosing CDLIM Motor Control Centre MCCLime Dosing PCDLIM Node NODE NODETYPE Lime or Acid system PHS Pipe Segment PIPSGMManholes ACMH Pipes PIPE PIPETYPE

Refers to Depot sites or coordinated Storage sites for Spare Equipment that

is not placed within any part of the relevant network

Term used to describe assets that are 'rotated' in and out of a location,facility or role. For example, there may be a store of submersble pumps that are rotated in and out of sewer pumpstations with a rebuild

after each rotation.

AssetLEVEL 5LEVEL 1 LEVEL 2 LEVEL 3

Network Scheme Name Facility/Sub-System Group

General Note: The asset level 2 will comprise the individual entries which will be arranged by type where that is of value,

otherwise it is the level 3 where the items are listed such as sensor

glass, valve spindle etc.

NOTE: There is a summary tab for these assets that lists summary and position details of facilities

To be finalised

LEVEL 4Function/Process

28/05/2014 1 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 2: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Rules Summary

LEVEL 6 LEVEL 7Asset Asset #

Network refers to either water or sewerage and

refers to all infrastructure owned by GRC within

either the collective water or sewerage networks

Prop

osed

abb

rev

key

Identifies individual pump station, or treatment plant

facility, buried infrastructure sub-system.

Prop

osed

abb

rev

key

A facility typically refers to pump stations, treatment plants, water quality stations. Sub-

systems refer to buried infrastructure and

appurtenances within a service area or catchment.

Prop

osed

abb

rev

key

Describes the facility/sub-system process or functional asset grouping.

Prop

osed

abb

rev

key

Asset Level 1 describes the asset within the facility/sub-system process or functional asset grouping, often referred to as the

parent level

Prop

osed

abb

rev

key Asset Level 2 describes the

maintenance managed item level. For example, the

pump, and the pump motor, and in some instances the

impeller.

Asset Level 3: Components can be

added to address maintenance managed

items such as pump impellers.

AssetLEVEL 5LEVEL 1 LEVEL 2 LEVEL 3

Network Scheme Name Facility/Sub-System GroupLEVEL 4

Function/Process

Micro filtration System FILuF Platforms PLATMixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPEOutlet Piping OUT Programmable Logic Controller PLC PLCTYPE Overflow System IOVR Pump PMP PUMPTYPE Pipe Segments PIPSGM Radio RAD RADIOTYPE Pipe Structures PIPSTRU Remote Terminal / Telemetry Unit RTUPipework and Valves RPVA Rising Sewer Mains RSEW SEWERTYPE Plant Bypass BYP Road / Parking Area ROADPlant Water Pipework UPWPVA Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE Plant Water Storage UPWSTO SCADA SCDAPolymer Dosing CDPOL Scales SCAL SCALETYPEPotable Water Pipework UWATPVA Screen / Sieve / Strainer SCR SCREENTYPE Potable Water Storage UWATSTO Security System SECSY SECURITYSYSTEMTYPE Potassium Permanganate Dosing CDKM Service Connection Pipe SCONN CONNECTIONTYPE Pre-treatment Activated Carbon Dosing PCDACC Software SOFT SOFTWARETYPE Pre-treatment Alum Dosing PCDALM Standpipe STNDPIPEPre-treatment Chemical Dosing General PCDS Structure STRU STRUCTURETYPE Pre-treatment Potassium Permanganate DosingPCDKM Sub-Meters SUBMPre-treatment Sulphuric Acid Dosing PCDACD Substation SUBS SUBMETERTYPE Primary Aeration 1AER Switchboard SWBRDPrimary Clarification 1CLA Tank TNK TANKTYPE Primary Process Instruments 1PI Telemetry TELE TELEMETRYTYPE Primary Process Power 1PP Transformer TRANS TRANSFORMERTYPE Pump System PSYS Uninterruptible Power Supply UPSPump System RLPMP UV Dosing Unit UVDOSPump System SPMP UV Lamp Cleaning Unit UVCLRRaw Aeration System RAER UV Lamps UVLMPRaw Filtration System RFILT Valve VAL VALVETYPE Raw Housing RHOU Vent / Ventilator VENT VENTTYPE Raw Intake Systems RINLT Walkway WALK WALKWAYTYPE Raw Pipework and Valves RLPVA Weir WEIR WEIRTYPE Raw Surge System RSURRaw Water Balance Storage RSTORaw Water Pumping System RPMPRelift System General RLSReturn Activated Sludge BIORASRising Mains RSEWRO System Electric ROELECRO System General ROSYSRO System Pipework ROPVARO System Pumping ROPMPRoof System ROFSYSR-Recycle BIORRECSecondary Aeration 2AERSecondary Aeration Blower 2BLOSecondary Air System 2AIRSecondary Clarification 2CLASecondary Mixed Liquor Recycling 2MLRSecondary Mixing 2MIXSecondary Pipework and Valves 2PVASecondary Process Instruments 2PISecondary Process Power 2PPSecondary Process Supporting Equipment 2SUPSecondary RAS Pumping 2RAPSecondary Reactor Basin Dewatering Systems2RBDSecondary Supporting Structures 2STRSedimentation Basins MIX SEDMIXSedimentation Basins Pipework SEDPVA

28/05/2014 2 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 3: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Rules Summary

LEVEL 6 LEVEL 7Asset Asset #

Network refers to either water or sewerage and

refers to all infrastructure owned by GRC within

either the collective water or sewerage networks

Prop

osed

abb

rev

key

Identifies individual pump station, or treatment plant

facility, buried infrastructure sub-system.

Prop

osed

abb

rev

key

A facility typically refers to pump stations, treatment plants, water quality stations. Sub-

systems refer to buried infrastructure and

appurtenances within a service area or catchment.

Prop

osed

abb

rev

key

Describes the facility/sub-system process or functional asset grouping.

Prop

osed

abb

rev

key

Asset Level 1 describes the asset within the facility/sub-system process or functional asset grouping, often referred to as the

parent level

Prop

osed

abb

rev

key Asset Level 2 describes the

maintenance managed item level. For example, the

pump, and the pump motor, and in some instances the

impeller.

Asset Level 3: Components can be

added to address maintenance managed

items such as pump impellers.

AssetLEVEL 5LEVEL 1 LEVEL 2 LEVEL 3

Network Scheme Name Facility/Sub-System GroupLEVEL 4

Function/Process

Sedimentation Basins Tanks SEDHOUService Laterals SCONNSite Power Generation SGENSite Wide Elec/Mech/Structural Systems SMEHSolids Dewatering SLDEWSolids Handling SLHANSolids Management System General SLSSolids Pipework SLPVASolids Process Sludge Conveyance SPCVSolids Process Sludge Pumping SPSPSolids Process Sludge Storage SPSSSolids Process Sludge Thickening SPSTSolids Process Waste Activated Solids PumpingSPWPSolids Process Pipework and Valves SPPVASolids Process Scum Control SPSCSolids Process Sludge Dewatering SPDWSolids Process Sludge Odour Control SPOCSolids Pumping SLPMPSolids Recirculation SLRECSolids Thickening SLTHKSolids Waste SLWASStorage Basins ESTORSuction System SUCTSulphuric Acid Dosing CDACDTank Stand STANDTank/Standpipe STORTertiary Aeration 3AERTertiary Chemical Dosing 3CDTertiary Disinfection 3DISTertiary Effluent Filtration 3EFFTertiary Effluent Storage 3ESTOTertiary Pipework and Valves 3PVATertiary Plant Water Pumping 3PWPTertiary Process Instrumentation 3PITertiary Process Power 3PPTreated Water Pipework TWPVATreated Water Pumping TWPMPTreated Water System General TWSUtilities Gas UGASUtilities Plant Water UPWUtilities Potable Water UWATUtilities Power UPOWWaste Activated Sludge BIOWAS

28/05/2014 3 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 4: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Rules Summary

LEVEL 6 LEVEL 7Asset Asset #

Network refers to either water or sewerage and

refers to all infrastructure owned by GRC within

either the collective water or sewerage networks

Prop

osed

abb

rev

key

Identifies individual pump station, or treatment plant

facility, buried infrastructure sub-system.

Prop

osed

abb

rev

key

A facility typically refers to pump stations, treatment plants, water quality stations. Sub-

systems refer to buried infrastructure and

appurtenances within a service area or catchment.

Prop

osed

abb

rev

key

Describes the facility/sub-system process or functional asset grouping.

Prop

osed

abb

rev

key

Asset Level 1 describes the asset within the facility/sub-system process or functional asset grouping, often referred to as the

parent level

Prop

osed

abb

rev

key Asset Level 2 describes the

maintenance managed item level. For example, the

pump, and the pump motor, and in some instances the

impeller.

Asset Level 3: Components can be

added to address maintenance managed

items such as pump impellers.

AssetLEVEL 5LEVEL 1 LEVEL 2 LEVEL 3

Network Scheme Name Facility/Sub-System GroupLEVEL 4

Function/Process

28/05/2014 4 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 5: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WTP

LEVEL 6 LEVEL 7Process Code Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEWater W Agnes Water AW Treatment Plant TP_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Actuator ACTU ACTUATORTYPEBororen BOR Aerator AERA AERATORTYPEBoyne Island BI Auger AUG AUGERTYPECalliope CAL Raw Water R Pipework and Valves RPVA Auto Sampler SAMP SAMPLERTYPECurtis Island CI Housing RHOU Aviation Lighting AVRLT LIGHTTYPEGladstone GLA Aeration System RAER Bearings* BEARMiriam Vale MV Intake Systems RINLT Belt Press* BELT PRESSTYPEMount Larcom ML Filtration System RFILT Bin Hopper BIN BINHOPPERTYPETannum Sands TS Raw Water Balance Storage RSTO Blower BLO BLOWERTYPEWurdong WUR Raw Water Pumping System RPMP Building BLD BUILDFUNCT Yarwun YAR Surge System RSUR Cable CAB CABLEUSE

Bores RBORE Cathodic Protection CATHP CATHODICTYPEChain and Flight System CHAIN CHAINFLIGHTTYPEChemical Feed System FEED FEEDERTYPECompressor COMP COMPRESSORTYPE

Inlet Works IN Pipework and Valves INPVA Conveyor CONY CONVEYORTYPE Housing INHOU Crane CRNE CRANETYPE Aeration System INAIR Electronic Data Capture EDCIntake Systems ININLT Fence FENC FENCETYPE Filtration System INFILT Filter FILT FILTERTYPEInlet Water Balance Storage INSTO Fire Fighting Equipment FIREQ FIRETYPE Inlet Water Pumping System INPMP Gear Box GBOXSurge System INSUR Heating Ventilation and Air-Conditioning HVAC HVACTYPE

Human Interface Terminal HITSInjector INJET INJECTORTYPE Instrument INST INSTRUMENTTYPELadders LADD LADDERTYPE

Pre-treatment Chemical Dosing PCD Pre-treatment Chemical Dosing General PCDSLandscaping LANS LANDSCAPETYPE

Potassium Permanganate Dosing PCDKM Lighting Systems LIGT LIGHTTYPE Activated Carbon Dosing PCDACC Lightning Protection Systems LTRPROTSulphuric Acid Dosing PCDACD Lime Slaker SLAKAlum Dosing PCDALM Liner Systems LNR LINERTYPE Lime Dosing PCDLIM Material Protection System MATPROT PROTECTIONTYPE

Media MEDR MEDIATYPE Meters MET METERTYPE Mixer MXR MIXERTYPE Motor MOTR MOTORTYPE

Flocculation FLOC Flocculator Pipework and Valves FLOCPVA Motor Control Centre MCCFlocculator Tanks and Structures FLOCHOS Pipes Water PIPE PIPETYPE Flocculator Rapid Mix System FLOMIX Platforms PLAT

Pond / Lagoon POND PONDTYPE Sedimentation SED Sedimentation Basins Pipework SEDPVA Power Supply PSUPP ENERGYTYPE

Sedimentation Basins Tanks SEDHOU Programmable Logic Controller PLC PLCTYPE Sedimentation Basins MIX SEDMIX Pump PMP PUMPTYPE

Radio RAD RADIOTYPE Filtration FIL Filtration Pressure Sand System FILPS Remote Terminal / Telemetry Unit RTU

Filter Disc System FILDS Road / Parking Area ROADMicro filtration System FILuF Rollers* ROLL SAFETYEQUIPMENTTYPE Filter Pressure Sand System Pipework FILPSPVA

Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE Filter Pressure Sand Pumping System FILPSPMP

SCADA SCDAScales SCAL SCALETYPE

Air Scour AIR Air Scour System General AIRS Screen / Sieve / Strainer SCR SCREENTYPE Air Scour System Pipework AIRPVA Security System SECSY SECURITYSYSTEMTYPE Air Scour System Mech AIRMECH Structure STRU STRUCTURETYPE Air Scour System Elec AIRELEC Switchboard SWBRD

Tank TNK TANKTYPE Backwash BACK Backwash System General BACKS Telemetry TELE TELEMETRYTYPE

Backwash System Pipework BACKPVA Transformer TRANS TRANSFORMERTYPE Backwash System Pump BACKPMP Uninterruptible Power Supply UPS

UV Dosing Unit UVDOSReverse Osmosis RO RO system General ROSYS UV Lamp Cleaning Unit UVCLR

RO System Pipework ROPVA UV Lamps UVLMPRO System Pumping ROPMP Valve VAL VALVETYPE RO System Electric ROELEC Vent / Ventilator VENT VENTTYPE

Walkway WALK WALKWAYTYPE Weir WEIR WEIRTYPE

Chemical Addition CD Chemical Dosing Systems General CDSPotassium Permanganate Dosing CDKMActivated Carbon Dosing CDACCSulphuric Acid Dosing CDACDAlum Dosing CDALM

*Refer to Appendix B to address level 5 Child assets of Level 5 Parent Assets

Raw Water Inlet, Treatment, Storage and Pumping - From any untreated source to and including the isolation valve to plant inlet or otherwise the terminal length of pipe to any balancing storage.

Plant Inlet System - Commencing at (not including) the isolation or NRV valve from Raw Water Pumping to the Treatment Plant Inlet works, to the isolation valve or relift pump NRV prior to any additional treatment.

Commencing at (not including) the isolation or NRV valve from Inlet Water Pumping to and including the isolation valve or terminal pipe to any further treatment.

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5

In the case of more than one treatment plant per scheme, the sub catchment served by the treatment plant is added to the description.

NOTE: A summary description of the specific Water Treatment Plant is also provided at this

level.

Network Scheme Name Facility/Sub-System Group

28/05/2014 5 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 6: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WTP

LEVEL 6 LEVEL 7Process Code Process Code Parent Asset Code Child Asset Child Asset Number

LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5Network Scheme Name Facility/Sub-System Group

Lime Dosing CDLIMPolymer Dosing CDPOLFerric Chloride Dosing CDFECL

Relift Pumping RL Relift System General RLSPump System RLPMPPipework and Valves RLPVA

Fluoridation FLU Fluoridation System FLUS

Ph Adjustment PH Lime or Acid system PHS

Disinfection DIS Disinfection System DISS

Treated or Clear Water Storage TW Treated Water System General TWSTreated Water Pumping TWPMPTreated Water Pipework TWPVA

Solids Process SL Solids Management System General SLSSolids Pipework SLPVASolids Pumping SLPMPSolids Thickening SLTHKSolids Recirculation SLRECSolids Dewatering SLDEWSolids Handling SLHANSolids Waste SLWAS

Power UPOW Plant Water Storage UPWSTOPlant Water UPW Plant Water Pipework UPWPVAPotable Water UWAT Potable Water Storage UWATSTOGas UGAS Potable Water Pipework UWATPVA

Gas Pipework UGASPVA

Building and Land Improvements BG Buildings and Grounds BG

Site Wide, Common Elements SMEH Site Wide Elec/Mech/Structural Systems

SMEH

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

Treatment Process System - Commencing at (not including) the isolation valve or end of terminal pipe from Pretreatment and including the isolation or NRV valve or terminal pipe to any pumping or chemical injection.

Intermediate System - Commencing at (not including) the isolation valve or end of terminal pipe from treatment , to and including the isolation or NRV valve or terminal pipe to clear water holding. This includes the disinfection, pH adjustment and fluoridation.

Treated or Clear Water Storage - Commencing at (not including) the isolation valve or end of terminal pipe from treatment, or intermediate systems to and including the isolation or NRV valve at the outlet side of the clear water holding.

Solids Process - Commencing at the isolation valve or solids collection structure to and including the final removal of solids waste stream from treatment site

Utilities - Commencing at the point of service entry to site and terminates at the service terminal point on site, ie service tap, plant switchboard, meter.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure.

28/05/2014 6 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 7: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WRESV

LEVEL 6 LEVEL 7Process Sub-Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEWater W Agnes Water AW Reservoir RESEV_catchment Access Roads and Paved Areas ROAD

Benaraby BEN Active Fire Alarm System FALRM FIREALARMTYPEBororen BOR Aviation Lighting AVRLT LIGHTTYPEBoyne Island BI Building BLD BUILDFUNCT Calliope CAL Elevated Tanks Tank Stand STAND Cathodic Protection CATHP CATHODICTYPECurtis Island CI Crane CRNE CRANETYPE Gladstone GLA Electronic Data Capture EDCMiriam Vale MV Fence FENC FENCETYPE Mount Larcom ML Fire Fighting Equipment FIREQ FIRETYPE Tannum Sands TS Ground or Elevated Tanks Inlet System INLT Fittings FITT FITTINGTYPE Wurdong WUR Heating Ventilation and Air-Conditioning HVAC HVACTYPE Yarwun YAR Instrument INST INSTRUMENTTYPE

Ladders LADD LADDERTYPE Landscaping LANS LANDSCAPETYPE Lighting Systems LIGT LIGHTTYPE

Ground or Elevated Tanks Tank/Standpipe STOR Lightning Protection Systems LTRPROTLiner Systems LNR LINERTYPE Material Protection System MATPROT PROTECTIONTYPE Meters MET METERTYPE Mixer MXR MIXERTYPE Motor MOTR MOTORTYPE

Ground or Elevated Tanks Roof System ROFSYS Pipes Water PIPE PIPETYPE Platforms PLATPump PMP PUMPTYPE Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE SCADA SCDASecurity System SECSY SECURITYSYSTEMTYPE Structure STRU STRUCTURETYPE

Ground or Elevated Tanks Shell SHELL Valve VAL VALVETYPE Vent / Ventilator VENT VENTTYPE Walkway WALK WALKWAYTYPE Weir WEIR WEIRTYPE

Ground or Elevated Tanks Mixing System MIX

Ground or Elevated Tanks Outlet Piping OUT

Ground or Elevated Tanks Bypass System BYPAS

Utilities Power UPOWPlant Water UPWPotable Water UWATGas UGAS

Buildings and Grounds Buildings and Grounds BG

Where there is no level4/5 Assets to be Maintained this asset can be managed at the Facility Level, using the Level 3 Summary Assets, with the appropriate Domain Lists.

LEVEL 5

The inlet system to any tank commences at the last isolation valve of the incoming main (whether sluice or backflow check) and terminates at the end of the pipework delivering water to the tank, i.e. if an eductor is used this includes the eductor.

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

Network Scheme Name Facility/Sub-System Group

This refers to the tank stand structure only where the stand is a separate structure to the tank. It includes any foundation works and safety equipment specific to the stand.

LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4

In the case of more than one reservoir per scheme, the subcatchment served by the reservoir is added to the description.

NOTE: A summary description of specific Reservoirs is also provided at this level.

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

The tank/standpipe is the component of the reservoir that stores and contains the fluid. It does not include drain, overflow or outlet works, but does include specific safety, security , instrumentation within intended zone for water storage.

The reservoir roof system includes the roof support system excluding the reservoir shell. That is any internal columns form part of this system. It also includes equipment including safety equipment that is directly attached and structurally dependant on the roof for its function.

The mixing system within the tank is that infrastructure specifically installed to promote even mixing of incoming water including any chemical dosing system where by a chemical is being added during the water storage at this site.

Outlet System includes the drain, overflow and outlet works. It commences from the infrastructure within the stored water zone that initiates the outlet flow and terminates at the terminal element of the pipework, i.e. overflow pipe frog-flap, or at the most upstream valve (sluice or check) above any inlet bypass pipe works. In the event of no bypass system the terminal element of the outlet system is the most downstream valve that isolates the reservoir outflow from the reservoir.

The bypass system is that system of valves, pipes and instrumentation that enables 'bypassing' of the reservoir such that the incoming main is directly flowing to the outgoing main. The bypass system commences at the fitting/valve on the incoming main and terminates at the junction of the bypass pipework to the outgoing main. Note this pipework is often installed within the same pit as inlet and outlet system valves.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

The reservoir shell is the external walls and base of the reservoir to which ladders, and other equipment are attached.

28/05/2014 7 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 8: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WPS

LEVEL 6 LEVEL 7Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEWater W Agnes Water AW Pump Stations PS_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Alternator* ALTBororen BOR Battery BATT BATTERYTYPEBoyne Island BI Battery Charging Unit CHAR BATTERYCHARGERTYPECalliope CAL Suction System SUCT Cable CAB CABLEUSECurtis Island CI Crane CRNE CRANETYPE Gladstone GLA Engine* ENGMiriam Vale MV Electronic Data Capture EDCMount Larcom ML Fence FENC FENCETYPE Tannum Sands TS Fire Fighting Equipment FIREQ FIRETYPE Wurdong WUR Pump System PSYS Fittings FITT FITTINGTYPE Yarwun YAR Fuel Storage System FULST

Gear Box GBOXGenerator Set GSET GENERATORTYPE Human Interface Terminal HITSInstrument INST INSTRUMENTTYPELadders LADD LADDERTYPE

Utilities UPOW Landscaping LANS LANDSCAPETYPE UPW Lighting Systems LIGT LIGHTTYPE UWAT Load Bank* LBNKUGAS Manholes ACMH MANHOLETYPE

Material Protection System MATPROT PROTECTIONTYPE Meters MET METERTYPE Motor MOTR MOTORTYPE Motor Control Centre MCC

Buildings and Grounds BG Pipes Water PIPE PIPETYPE Power Supply PSUPP ENERGYTYPEProgrammable Logic Controller PLC PLCTYPE Pump PMP PUMPTYPE Road / Parking Area ROAD

Site Wide, Common Elements SMEH Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE SCADA SCDASecurity System SECSY SECURITYSYSTEMTYPE Structure STRU STRUCTURETYPE Substation SUBS SUBMETERTYPE Switchboard SWBRDTelemetry TELE TELEMETRYTYPE Transformer TRANS TRANSFORMERTYPE Uninterruptible Power Supply UPSValve VAL VALVETYPE Walkway WALK WALKWAYTYPE

*Refer to Appendix B to address level 5 Child assets of Level 5 Parent Assets

LEVEL 5LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4Network Scheme Name Facility/Sub-System Group

The suction/inlet side of the pump station commences at inlet works foot valve, check valve, non-return valve of incoming network main, or terminal valve of reservoir outlet system and continues to and includes the pump inlet isolation valve.

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.In the case of more than one pump station per

scheme, the catchment served by the pumpstation is added to the description.

NOTE: A summary description of the specific Water Treatment Plant is also provided at this level.

The pump station pumping system commences from the pump inlet isolation valve continues through to pump discharge line non-return valve where the network pipe segments commence. This includes any flow metering instrumentation and flow based chemical dosing systems between these spatial limits

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

28/05/2014 8 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 9: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WNET

LEVEL 5 LEVEL 7 LEVEL 8Parent Level Asset Code Parent Asset # Child Asset Code Sub Child Asset Child or Sub Child Asset #

1770 1770 Network Nodes NNODE Fittings FITT FITTINGTYPE Water W Agnes Water AW Distribution/Reticulation System NET_catchment Hydrant HYDN HYDRANTTYPE

Benaraby BEN Instrument INST INSTRUMENTTYPEBororen BOR Meters MET METERTYPE Boyne Island BI Service Connection Pipe SCONN CONNECTIONTYPE Calliope CAL Pipe Segments PIPSGM Structure STRU STRUCTURETYPE Curtis Island CI Valve VAL VALVETYPE Gladstone GLA GPS Position GGPSMiriam Vale MVMount Larcom MLTannum Sands TS Pipe Structures PIPSTRUWurdong WURYarwun YAR Reticulation Structures for the pipes are those structures required for

the pipe connection function to be maintained. This only refers to pipe bridges, a system of supports, submarine sections.

Nodes represent the beginning and end points of pipe segments. Each node may represent a valve, pipe junction, pit, meter

Pipe segments commence and end with a node. All fittings, hydrants, valves , laterals become pipe children

LEVEL 6Network Scheme Name Facility/Sub-System GroupLEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4

In the case of more than one distribution network per scheme, the network subcatchment/pressure zone name is added to the description.

28/05/2014 9 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 10: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WWTP

LEVEL 6 LEVEL 7Process Code Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEWastewater WW Agnes Water AW Treatment Plant TP_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Aerator AERA AERATORTYPEBororen BOR Alternator* ALTBoyne Island BI Auto Sampler SAMP SAMPLERTYPECalliope CAL Influent and Inlet Systems I Influent Pumping Station IPS Bearings* BEARCurtis Island CI Inlet Channel ICHAN Belt Press* BELT PRESSTYPEGladstone GLA Influent Pipework IPVA Bin Hopper BIN BINHOPPERTYPEMiriam Vale MV Influent Dosing with chemical n ICDn Blower BLO BLOWERTYPEMount Larcom ML Influent Screening ISCR Building BLD BUILDFUNCT Tannum Sands TS Influent Grit Removal IGTR Cable CAB CABLEUSE

Wurdong WURBalance Tank and associated Equipment ISTO

Cathodic Protection CATHP CATHODICTYPEYarwun YAR Overflow System IOVR Compactor CMPA

Emergency Storage System IEMS Compressor COMP COMPRESSORTYPEConveyor CONY CONVEYORTYPE Crane CRNE CRANETYPE

Bypass BYP Plant Bypass BYP Electronic Data Capture EDCEmergency Storage EMS EMSTYPE Engine* ENGFan FAN FANTYPE Fence FENC FENCETYPE Filter FILT FILTERTYPE

Primary 1 Primary Clarification 1CLA Fire Fighting Equipment FIREQ FIRETYPE Primary Aeration 1AER Fittings FITT FITTINGTYPE Primary Process Instruments 1PI Gear Box GBOXPrimary Process Power 1PP Generator Set* GSET GENERATORTYPE

Gravity Sewers GSEW SEWERTYPE This refers to 'primary' treatment process train and elements. Grit Removal GITR GRITCHAMBERTYPE

Guide Rail GRAILSecondary 2 Secondary Aeration 2AER Heating Ventilation and Air-Conditioning HVAC HVACTYPE

Secondary Aeration Blower 2BLO Human Interface Terminal HITSSecondary Mixing 2MIX Injector INJET INJECTORTYPE Secondary Reactor Basin Dewatering Systems 2RBD

Instrument INST INSTRUMENTTYPESecondary Clarification 2CLA Ladders LADD LADDERTYPE Secondary Mixed Liquor Recycling 2MLR Landscaping LANS LANDSCAPETYPE Secondary Air System 2AIR Lighting Systems LIGT LIGHTTYPE Secondary RAS Pumping 2RAP Load Bank* LBNKSecondary Process Instruments 2PI Manholes ACMH MANHOLETYPE Secondary Process Power 2PP Material Protection System MATPROT PROTECTIONTYPE Secondary Process Supporting Equipment 2SUP Meters MET METERTYPE Secondary Supporting Structures 2STR Mixer MXR MIXERTYPE Secondary Pipework and Valves 2PVA Motor MOTR MOTORTYPE

Motor Control Centre MCCThis refers to 'secondary' treatment process train and elements. Pipes Water PIPE PIPETYPE

Pipes Water PIPE PIPETYPE Tertiary 3 Tertiary Effluent Storage 3ESTO Platforms PLAT

Tertiary Effluent Filtration 3EFF Pond / Lagoon POND PONDTYPE Tertiary Disinfection 3DIS Power Supply PSUPP ENERGYTYPETertiary Aeration 3AER Programmable Logic Controller PLC PLCTYPE Tertiary Process Instrumentation 3PI Pump PMP PUMPTYPE Tertiary Chemical Dosing (for each chemical) 3CD

Radio RAD RADIOTYPE Tertiary Plant Water Pumping 3PWP Remote Terminal / Telemetry Unit RTUTertiary Process Power 3PP Rising Sewer Mains RSEW SEWERTYPE Tertiary Pipework and Valves 3PVA Rollers* ROLL

Road / Parking Area ROADThis refers to 'Tertiary' treatment process train and elements. Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE

SCADA SCDABioreactor BIO Bioreactor Structure BIOREAC Screen / Sieve / Strainer SCR SCREENTYPE

Bioreactor Inlet Pipe work BIOIPVA Security System SECSY SECURITYSYSTEMTYPE Bioreactor Anaerobic Zone BIOANE Structure STRU STRUCTURETYPE Anaerobic Zone 1 , Anaerobic Zone n Switchboard SWBRDBioreactor Anoxic Zone BIOANO Tank TNK TANKTYPE Preliminary/Secondary Anoxic Zone Telemetry TELE TELEMETRYTYPE Bioreactor Aerobic Zone BIOAER Transformer TRANS TRANSFORMERTYPE Aerobic Zone 1 , n Uninterruptible Power Supply UPSReturn Activated Sludge BIORAS UV Dosing Unit UVDOSWaste Activated Sludge BIOWAS UV Lamp Cleaning Unit UVCLRA-Recycle BIOAREC UV Lamps UVLMPR-Recycle BIORREC Valve VAL VALVETYPE Blowers BIOBLO Vent / Ventilator VENT VENTTYPE

LEVEL 5LEVEL 4LEVEL 1 LEVEL 2 LEVEL 3Network Scheme Name Facility/Sub-System Group

In the case of more than one treatment plant per scheme, the catchment served by the treatment plant is added to the description.

NOTE: A summary description of the specific Wastewater Treatment Plant is also provided at this level.

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

Depending on where the plant bypass originates from, the extent of the bypass system commences from the bypass activation valve and continues to its terminal location, inclusive of structures, headwall and instrumentation.

From any untreated source to and including the isolation valve to treatment process inlet

28/05/2014 10 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 11: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WWTP

LEVEL 6 LEVEL 7Process Code Process Code Parent Asset Code Child Asset Child Asset Number

LEVEL 5LEVEL 4LEVEL 1 LEVEL 2 LEVEL 3Network Scheme Name Facility/Sub-System Group

Bioreactor Scum Management BIOSCM Walkway WALK WALKWAYTYPE Weir WEIR WEIRTYPE

This refers to overall bioreactor treatment process train, structure and elements.

Solids Process SP Solids Process Waste Activated Solids Pumping SPWP

Solids Process Sludge Thickening SPSTSolids Process Sludge Pumping SPSPSolids Process Sludge Storage SPSSSolids Process Sludge Dewatering SPDWSolids Process Sludge Conveyance SPCVSolids Process Sludge Odour Control SPOCSolids Process Scum Control SPSCSolids Process Pipework and Valves SPPVA

Effluent Management System EFF Effluent Chlorine Contact tank CDOSEEffluent Storage EFFSEffluent Pump Station EFFPSP

Disposal System Infrastructure. DIS Disposal System Pipework and Valves DISPVADisposal Balance Tank DISBTNKDisposal Pump Station DISPSP

Utilities U Utilities Power UPOWUtilities Plant Water UPWUtilities Potable Water UWATUtilities Gas UGAS

Commencing at the point of

Building and Land Improvements

BG Buildings and Grounds BG

To be applied for the overall

Site Wide, Common Elements

SMEH Site Wide Elec/Mech/Structural Systems SMEH

*Refer to Appendix B to address level 5 Child assets of Level 5 Parent Assets

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

Commencing at the isolation valve or solids collection structure to and including the final removal of solids waste stream from treatment site

Effluent Management system ( commences at the inlet to the contank system ie downstream of the last isolation valve or at the discharge end of the pipework from treatment, and concludes at the terminal valve

or pipe leading to recycled water ( or effluent Pumpstation) NRV.

Commencing at (not including) the isolation valve or end of terminal pipe from treatment, or intermediate systems to and including the isolation or NRV valve at the outlet side of the clear water holding.

28/05/2014 11 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 12: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WWPS

LEVEL 6 LEVEL 7Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEWastewater WW Agnes Water AW Pump Stations PS_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Alternator* ALTBororen BOR Building BLD BUILDFUNCT Boyne Island BI Compactor CMPACalliope CAL Controller CONT CONTOLLERTYPE Curtis Island CI Conveyor CONY CONVEYORTYPE Gladstone GLA Influent System ISYS Crane CRNE CRANETYPE Miriam Vale MV Emergency Storage EMS EMSTYPE Mount Larcom ML Engine* ENGTannum Sands TS Fan FAN FANTYPE Wurdong WUR Fence FENC FENCETYPE Yarwun YAR Effluent System EFFL Filter FILT FILTERTYPE

Fire Fighting Equipment FIREQ FIRETYPE Generator Set GSET GENERATORTYPE Grinder GRNDGuide Rail GRAILHeating Ventilation and Air-Conditioning HVAC HVACTYPE Human Interface Terminal HITS

Rising Main RSEW Instrument INST INSTRUMENTTYPELadders LADD LADDERTYPE Landscaping LANS LANDSCAPETYPE Lighting Systems LIGT LIGHTTYPE Load Bank* LBNK

Pump System SPMP Manholes ACMH MANHOLETYPE Meters MET METERTYPE Motor MOTR MOTORTYPE Motor Control Centre MCCPipes Water PIPE PIPETYPE Power Supply PSUPP ENERGYTYPEProgrammable Logic Controller PLC PLCTYPE

Utilities UPOW Pump PMP PUMPTYPE UPW Radio RAD RADIOTYPE UWAT Remote Terminal / Telemetry Unit RTUUGAS Rising Sewer Mains RSEW SEWERTYPE

Road / Parking Area ROADSafety Equipment SAFEQ SAFETYEQUIPMENTTYPE SCADA SCDAScreen / Sieve / Strainer SCR SCREENTYPE

Buildings and Grounds BG Security System SECSY SECURITYSYSTEMTYPE Structure STRU STRUCTURETYPE Switchboard SWBRDTransformer TRANS TRANSFORMERTYPE Uninterruptible Power Supply UPS

Site Wide, Common Elements SMEH Valve VAL VALVETYPE Vent / Ventilator VENT VENTTYPE Walkway WALK WALKWAYTYPE

*Refer to Appendix B to address level 5 Child assets of Level 5 Parent Assets

LEVEL 5Network Scheme Name Facility/Sub-System GroupLEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4

In the case of more than one pump station per scheme, the collection zone name served by the pumpstation is added to the description.

NOTE: A summary description of specific Wastewater Pump Station is also provided at

this level.

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.NOTE: For Wastewater Pump Stations, the following demarcation rules apply: The gravity collection system upstream of a Pump Station is titled by the first pump station it reports to.

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

The pump station system commences at the pump well and continues to and includes the discharge line non-return valve or isolation valve, or the terminal outlet of discharge point to atmosphere if pumping to gravity sewer or pond system.

The rising or force main system commences immediately downstream of the effluent system isolation valve.

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

The influent system of a pump station commences at the flow metering pit or zero manhole which-ever occurs first

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

The effluent system commences immediately downstream of the pump station pumping system NRV and continues to the flow metering pit or isolation valve whichever is the most downstream location which should include any pigging chamber for the pump station

28/05/2014 12 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 13: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WWCOLL

LEVEL 5 LEVEL 7 LEVEL 8Parent Level Asset Code Parent Asset Number Child Asset Code Sub Child Asset Child or Sub Child Asset Number

1770 1770 # Access Lid ACLID ACCESSCOVERTYPEWastewater WW Agnes Water AW Collection Systems COLL_catchment Fitting FITT FITTINGTYPE

Benaraby BEN Grinder GRNDBororen BOR Instrument INST INSTRUMENTTYPEBoyne Island BI Ladders LADD LADDERTYPE Calliope CAL Service Laterals SCONN Manholes ACMH MANHOLETYPE Curtis Island CI Meters MET METERTYPE Gladstone GLA Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE Miriam Vale MV Structure STRU STRUCTURETYPE Mount Larcom ML Valve VAL VALVETYPE Tannum Sands TS Manholes ACMH Vent / Ventilator VENT VENTTYPE Wurdong WURYarwun YAR

Sewer GSEW

Rising Mains RSEW

Combined Rising Main CRSEW

Network Nodes NNODE

LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4Network Scheme Name Facility/Sub-System Group

In the case of more than one collection system per scheme, the collection sub-system name/number is added to the description.

LEVEL 6

Within the Wastewater Collection Network, all sewers are represented as a PIPE, between NODES which are typically manholes (In which case they are ACMH parents, otherwise NNODE). Use of NNODE enables the Sewer or Rising Main to be terminated at isolation valves, pipe tee, of pipe size change where the is no manhole, i.e. within Rising Mains.

Manholes/Maintenance Access Chambers include the structure, lid, rocker jointing, internal/external drops, penstocks and benching.

Combined rising mains extend from the main junction point/manhole and retain the scheme name of their originating Pump Station,

Service Laterals extend from a collection sewer to the property connection, jump up. The service lateral includes the sewer entry and the jump up chamber/pit only.

Rising mains commence immediately downstream of the Pump station isolating valve. Rising mains retain the scheme name of their originating Pump station until meeting

influent system of new pump station or become combined rising main.

Sewers run from manhole to manhole.

NNODE enables the Sewer or Rising Main to be terminated at isolation valves, pipe tee, of pipe size change where the is no manhole, i.e. within Rising Mains.

28/05/2014 13 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 14: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WWSTOR

LEVEL 6 LEVEL 7Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEWastewater WW Agnes Water AW Storage STOR_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Building BLD BUILDFUNCT Bororen BOR Compactor CMPABoyne Island BI Controller CONT CONTOLLERTYPE Calliope CAL Conveyor CONY CONVEYORTYPE Curtis Island CI Crane CRNE CRANETYPE Gladstone GLA Emergency Storage EMS EMSTYPE Miriam Vale MV Fan FAN FANTYPE Mount Larcom ML Fence FENC FENCETYPE Tannum Sands TS Fire Fighting Equipment FIREQ FIRETYPE Wurdong WUR Grinder GRNDYarwun YAR Heating Ventilation and Air-Conditioning HVAC HVACTYPE

Influent System ISYS Human Interface Terminal HITSInstrument INST INSTRUMENTTYPELadders LADD LADDERTYPE Landscaping LANS LANDSCAPETYPE Lighting Systems LIGT LIGHTTYPE Maintenance Access / Manholes ACMH MANHOLETYPE Material Protection System MATPROT PROTECTIONTYPE

Storage Basins ESTOR Meters MET METERTYPE Motor MOTR MOTORTYPE Pipes Water PIPE PIPETYPE Power Supply PSUPP ENERGYTYPEProgrammable Logic Controller PLC PLCTYPE Pump PMP PUMPTYPE

Pump System SPMP Radio RAD RADIOTYPE Remote Terminal / Telemetry Unit RTURising Sewer Mains RSEW SEWERTYPE Road / Parking Area ROADSafety Equipment SAFEQ SAFETYEQUIPMENTTYPE SCADA SCDAScreen / Sieve / Strainer SCR SCREENTYPE

Effluent System EFFL Security System SECSY SECURITYSYSTEMTYPE Structure STRU STRUCTURETYPE Structure Access Ladders and Walkways WALKSwitchboard SWBRDValve VAL VALVETYPE Vent / Ventilator VENT VENTTYPE Walkway WALK WALKWAYTYPE

Utilities UPOWUPWUWATUGAS

Buildings and Grounds BG

Site Wide, Common Elements SMEH

LEVEL 5LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4Network Scheme Name Facility/Sub-System Group

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

In the case of more than one effluent storage system per scheme, the collection system

name/number served by the storage is added to the description.

Wastewater Storage Facility is where waste water is stored for reuse or disposal. In some instances the 'storage' is itself a treatment process stage. In those instances the storage is to be incorporated into the WWTP asset hierarchy. The instances where this asset type is used are where the 'storage' is offsite from the WWTP and is intended to include camper effluent dump tanks, treated effluent storage ponds (i.e. Golf Club), or final effluent evaporation ponds where these are located outside of the WWTP site.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

The influent system of a wastewater storage system commences at the flow metering pit, zero manhole, or isolation valve which-ever occurs first and continues to and includes the entry/inlet structure of basin/tank. This includes the flow measurement flumes and/or meters

The storage basin is a structure for the containment, storage of wastewater. All assets excluding the inlet pit and includes discharge pits, drain, scour pipework, recirculation, instrumentation, baffles within the basin are included

The pump system (if required) extends from and including the pumping system isolation valve (Gate or NRV) to the terminal end of the pump discharge pipework, i.e. the end of the pump discharge manifold, NRV or metering location. It includes all the pumping equipment and instrumentation attached.

The effluent system is pipework, valves, metering and sampling equipment extending from the discharge pit to/from any intermediate pumping system, and where appropriate includes pipework to and including the isolation valve of disposal systems such as outfall discharge piping, metering and structures.

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

28/05/2014 14 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 15: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 WWDISP

LEVEL 6 LEVEL 7Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Active Fire Alarm System FALRM FIREALARMTYPEWastewater WW Agnes Water AW Disposal System DISP Auto Sampler SAMP SAMPLERTYPE

Benaraby BEN Building BLD BUILDFUNCT Bororen BOR Cable CAB CABLEUSEBoyne Island BI Compactor CMPACalliope CAL Controller CONT CONTOLLERTYPE Curtis Island CI Conveyor CONY CONVEYORTYPE Gladstone GLA Crane CRNE CRANETYPE Miriam Vale MV Fan FAN FANTYPE Mount Larcom ML Fence FENC FENCETYPE Tannum Sands TS Fire Fighting Equipment FIREQ FIRETYPE Wurdong WUR Disposal Systems Grinder GRNDYarwun YAR Heating Ventilation and Air-Conditioning HVAC HVACTYPE

Disposal System Pipework and Valves DISPVA Human Interface Terminal HITSDisposal Outfall DISOUTF Instrument INST INSTRUMENTTYPEDisposal Irrigation System DISIRR Landscaping LANS LANDSCAPETYPE

Lighting Systems LIGT LIGHTTYPE Meters MET METERTYPE Motor MOTR MOTORTYPE Motor Control Centre MCCPipes Water PIPE PIPETYPE

Pump System SPMP Power Supply PSUPP ENERGYTYPEProgrammable Logic Controller PLC PLCTYPE Pump PMP PUMPTYPE Radio RAD RADIOTYPE Remote Terminal / Telemetry Unit RTURising Sewer Mains RSEW SEWERTYPE Road / Parking Area ROAD

Utilities UPOW Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE UPW SCADA SCDAUWAT Screen / Sieve / Strainer SCR SCREENTYPE UGAS Security System SECSY SECURITYSYSTEMTYPE

Structure STRU STRUCTURETYPE Switchboard SWBRDValve VAL VALVETYPE Vent / Ventilator VENT VENTTYPE

Buildings and Grounds BG Walkway WALK WALKWAYTYPE

Site Wide, Common Elements SMEH

LEVEL 5

The pump system (if required) extends from and including the pumping system isolation valve (Gate or NRV) to the terminal end of the pump discharge pipework, i.e. the end of the pump discharge manifold, NRV or metering location. It includes all the pumping equipment and instrumentation attached.

LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4Network Scheme Name Facility/Sub-System Group

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

Wastewater Disposal Systems are those which convey wastewater (treated or un-treated) to the terminal placement position. This includes outfalls to creek and/or ocean discharge, land application irrigation systems, and pipework that transports effluent to a third party disposal and/or use scheme.

Commencing at (not including) the isolation valve or end of terminal pipe from treatment, or intermediate systems to the NRV valve at the inlet side of any disposal pumping system, to the terminal placement position of the wastewater.

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

28/05/2014 15 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 16: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 RWPS

LEVEL 6 LEVEL 7Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPERecycled Water RW Agnes Water AW Pump Stations PS_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Alternator* ALTBororen BOR Battery BATT BATTERYTYPEBoyne Island BI Battery Charging Unit CHAR BATTERYCHARGERTYPECalliope CAL Suction System SUCT Cable CAB CABLEUSECurtis Island CI Crane CRNE CRANETYPE Gladstone GLA Electronic Data Capture EDCMiriam Vale MV Engine* ENGMount Larcom ML Fence FENC FENCETYPE Tannum Sands TS Fire Fighting Equipment FIREQ FIRETYPE Wurdong WUR Pump System PSYS Fittings FITT FITTINGTYPE Yarwun YAR Fuel Storage System FULST

Gear Box GBOXGenerator Set* GSET GENERATORTYPE Human Interface Terminal HITSInstrument INST INSTRUMENTTYPELadders LADD LADDERTYPE

Utilities UPOW Landscaping LANS LANDSCAPETYPE UPW Lighting Systems LIGT LIGHTTYPE UWAT Load Bank* LBNKUGAS Manholes ACMH MANHOLETYPE

Material Protection System MATPROT PROTECTIONTYPE Meters MET METERTYPE Motor MOTR MOTORTYPE Motor Control Centre MCC

Buildings and Grounds BG Pipes Water PIPE PIPETYPE Power Supply PSUPP ENERGYTYPEProgrammable Logic Controller PLC PLCTYPE Pump PMP PUMPTYPE Road / Parking Area ROAD

Site Wide, Common Elements SMEH Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE SCADA SCDASecurity System SECSY SECURITYSYSTEMTYPE Structure STRU STRUCTURETYPE Substation SUBS SUBMETERTYPE Switchboard SWBRDTelemetry TELE TELEMETRYTYPE Transformer TRANS TRANSFORMERTYPE Uninterruptible Power Supply UPSValve VAL VALVETYPE Walkway WALK WALKWAYTYPE

*Refer to Appendix B to address level 5 Child assets of Level 5 Parent Assets

LEVEL 5LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

Network Scheme Name Facility/Sub-System Group

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

The suction/inlet side of the pump station commences at inlet works foot valve, check valve, non-return valve of incoming network main, or terminal valve of Reservoir outlet system and continues to and includes the pump inlet isolation valve.

The pump station pumping system commences from the pump inlet isolation valve continues through to pump discharge line non-return valve where the network pipe segments commence. This includes any flow metering instrumentation and flow based chemical dosing systems between these spatial limits

In the case of more than one pump station per scheme, the sub-scheme served by the pump station is added to the description.

NOTE: A summary description of specific Recycled Water Pump Stations is also provided

at this level.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

28/05/2014 16 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 17: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 RWNET

Parent Level Asset Code Parent Asset Number Child Asset Code Sub Child Asset Child or Sub Child Asset Number1770 1770 Network Nodes NNODE # Fittings FITT FITTINGTYPE

Recycled Water RW Agnes Water AW Distribution/Reticulation System NET_catchment Hydrant HYDN HYDRANTTYPE Benaraby BEN Instrument INST INSTRUMENTTYPEBororen BOR Meters MET METERTYPE Boyne Island BI Node NODE NODETYPE Calliope CAL Pipe Segments PIPSGM Service Connection Pipe SCONN CONNECTIONTYPE Curtis Island CI Structure STRU STRUCTURETYPE Gladstone GLA Valve VAL VALVETYPE Miriam Vale MVMount Larcom MLTannum Sands TS Pipe Structures PIPSTRUWurdong WURYarwun YAR

Network Scheme Name Facility/Sub-System Group

In the case of more than one distribution network per scheme, the network subcatchment name is added to the description.

Reticulation Structures for the pipes are those structures required for the pipe connection function to be maintained. This only refers to pipe bridges, a system of supports,

Nodes represent the beginning and end points of pipe segments. Each node may represent a valve, pipe junction,

Pipe segments commence and end with a node. All fittings, hydrants, valves, laterals become pipe children

28/05/2014 17 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 18: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 BWPS

LEVEL 6 LEVEL 7Process Code Parent Asset Code Child Asset Child Asset Number

1770 1770 Access Lid ACLID ACCESSCOVERTYPEBulk Water BW Agnes Water AW Pump Stations PS_catchment Active Fire Alarm System FALRM FIREALARMTYPE

Benaraby BEN Alternator* ALTBororen BOR Battery BATT BATTERYTYPEBoyne Island BI Battery Charging Unit CHAR BATTERYCHARGERTYPECalliope CAL Suction System SUCT Cable CAB CABLEUSECurtis Island CI Crane CRNE CRANETYPE Gladstone GLA Electronic Data Capture EDCMiriam Vale MV Engine* ENGMount Larcom ML Fence FENC FENCETYPE Tannum Sands TS Fire Fighting Equipment FIREQ FIRETYPE Wurdong WUR Pump System PSYS Fittings FITT FITTINGTYPE Yarwun YAR Fuel Storage System FULST

Gear Box GBOXGenerator Set* GSET GENERATORTYPE Human Interface Terminal HITSInstrument INST INSTRUMENTTYPELadders LADD LADDERTYPE

Utilities UPOW Landscaping LANS LANDSCAPETYPE UPW Lighting Systems LIGT LIGHTTYPE UWAT Load Bank* LBNKUGAS Manholes ACMH MANHOLETYPE

Material Protection System MATPROT PROTECTIONTYPE Meters MET METERTYPE Motor MOTR MOTORTYPE Motor Control Centre MCC

Buildings and Grounds BG Pipes Water PIPE PIPETYPE Power Supply PSUPP ENERGYTYPEProgrammable Logic Controller PLC PLCTYPE Pump PMP PUMPTYPE Road / Parking Area ROAD

Site Wide, Common Elements SMEH Safety Equipment SAFEQ SAFETYEQUIPMENTTYPE SCADA SCDASecurity System SECSY SECURITYSYSTEMTYPE Structure STRU STRUCTURETYPE Substation SUBS SUBMETERTYPE Switchboard SWBRDTelemetry TELE TELEMETRYTYPE Transformer TRANS TRANSFORMERTYPE Uninterruptible Power Supply UPSValve VAL VALVETYPE Walkway WALK WALKWAYTYPE

*Refer to Appendix B to address level 5 Child assets of Level 5 Parent Assets

LEVEL 5LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4

The intent of the Sub-Process delimitation is to separate the plant into the identifiable process elements. IDEALLY the process elements are best identified from the Plant P&ID or Process Flow Diagrams with the processes delimited by valves (generally isolation) or at an outfall to another process.

Network Scheme Name Facility/Sub-System Group

Commencing at the point of service entry to site and terminates at the service terminal point on site, i.e. service tap, plant switchboard, meter.

The suction/inlet side of the pump station commences at inlet works footvalve, check valve, non-return valve of incoming network main, or terminal valve of Reservoir outlet system and continues to and includes the pump inlet isolation valve.

The pump station pumping system commences from the pump inlet isolation valve continues through to pump discharge line non-return valve where the network pipe segments commence. This includes any flow metering instrumentation and flow based chemical dosing systems between these spatial limits

NOTE: A summary description of specific Bulk Water Pump Stations is also provided at this

level.

In the case of more than one pump station per scheme, the actual location of the facility should be added to the description.

To be applied for the overall site. Only to be utilised for multiuse structures and infrastructure

Only to be used for items of infrastructure that apply to the site at large as opposed to any individual structure or building and are maintained for site wide usage

28/05/2014 18 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 19: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 BWNET

LEVEL 5 LEVEL 7 LEVEL 8Parent Level Asset Code Parent Asset Number Child Asset Code Sub Child Asset Child or Sub Child Asset Number

1770 1770 Network Nodes NNODE # Fittings FITT FITTINGTYPE Bulk Water BW Agnes Water AW Distribution/Reticulation System NET_catchment Hydrant HYDN HYDRANTTYPE

Benaraby BEN Instrument INST INSTRUMENTTYPEBororen BOR Meters MET METERTYPE Boyne Island BI Node NODE NODETYPE Calliope CAL Pipe Segments PIPSGM Service Connection Pipe SCONN CONNECTIONTYPE Curtis Island CI Structure STRU STRUCTURETYPE Gladstone GLA Valve VAL VALVETYPE Miriam Vale MVMount Larcom MLTannum Sands TS Pipe Structures PIPSTRUWurdong WURYarwun YAR

LEVEL 6Network Scheme Name Facility/Sub-System GroupLEVEL 1 LEVEL 2 LEVEL 3

In the case of more than one distribution network per scheme, the network subcatchment name is added to the description.

Reticulation Structures for the pipes are those structures required for the pipe connection function to be maintained. This only refers to pipe bridges, a system of supports,

LEVEL 4

Nodes represent the beginning and end points of pipe segments. Each node may represent a valve, pipe junction,

Pipe segments commence and end with a node. All fittings, hydrants, valves, laterals become pipe children

28/05/2014 19 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 20: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Level 3 Summary Assets

GRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement

SI Unit Domain List Name

ASSET IDREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no RESERVOIR INSTALLATION INSTALLATIONCAPACITY kilolitres kLCONSTRUCTION TYPE CONSTRUCTIONTYPEDIMENSION 1 (DIAMETER) Metres mDIMENSION 2 Metres mFLOOR LEVEL (RL) Metres mFLOOR MATERIAL CONSTRUCTEDMATERIALWALL MATERIAL CONSTRUCTEDMATERIALHEIGHT / DEPTH Metres mNUMBER OF ACCESS POINTS NumberPRIMARY ACCESS DIMENSION 1 (DIAMETER) Metres mPRIMARY ACCESS DIMENSION 2 Metres mPRIMARY ACCESS LID MATERIAL ACCESSLIDMATERIALPRIMARY ACCESS TYPE ACCESSTYPEROOF ACCESS METHOD Stairs / Ladder ACCESSTYPEROOF / COVER MATERIAL CONSTRUCTEDMATERIAL TOP WATER LEVEL (RL) Metres mSHAPE SHAPEINLET TYPE OUTLET/INLET/OVERFLOWTYPEINLET MATERIAL PIPEMATERIALINLET DIMENSION millimetres mm INLET LEVEL (RL) Metres mOUTLET TYPE OUTLET/INLET/OVERFLOWTYPEOUTLET DIMENSION millimetres mm OUTLET MATERIAL PIPEMATERIALOUTLET LEVEL (RL) Metres mOVERFLOW TYPE OUTLET/INLET/OVERFLOWTYPEOVERFLOW DIMENSION millimetres mm OVERFLOW MATERIAL PIPEMATERIALOVERFLOW LEVEL (RL) Metres mCATHODIC PROTECTED NO/YES ASSET IDACCESSIBILITY ACCESSTYPE

RESERVOIR -- RESV A RESERVOIR IS A SPECFIC TYPE OF TANK STRUCTURE. THE RESERVOIR ASSET TYPE INCLUDES GROUND LEVEL RESERVOIRS AS WELL AS WATER TOWERS. ONLY USE THIS COMPLETE TAB WHERE THERE ARE NO LEVEL 4 OR 5 ASSETS TO BE MAINTAINED, OTHER WISE ONLY USE THE RED SHADED CELLS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 20 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 21: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Level 3 Summary Assets

ASSET ID Conquest Generated number no.REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no PROPERTY PARCEL/LOT textCAPACITY ML/day MLNUMBER OF PUMPS number no.SEPARATE DUTY/STANDBY PROVISION Yes/NoDUTY POINT HEAD Metres mDUTY POINT FLOW Litres/sec L/secFLOOR MATERIAL CONSTRUCTEDMATERIALWALL MATERIAL CONSTRUCTEDMATERIALROOFMATERIAL CONSTRUCTEDMATERIALPRIMARY ACCESS TYPE ACCESSTYPEINLET TYPE OUTLET/INLET/OVERFLOWTYPEINLET MATERIAL PIPEMATERIALINLET DIMENSION millimetres mm OUTLET TYPE OUTLET/INLET/OVERFLOWTYPEOUTLET DIMENSION millimetres mm OUTLET MATERIAL PIPEMATERIALFIRE ALARM Yes/NoACCESS ALARM Yes/NoKEY SECURITY LEVEL number no.

WATER PUMP STATION -- WPS

THIS IS THE WATER PUMP STATION SUMMARY TAB.Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 21 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 22: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Level 3 Summary Assets

ASSET IDConquest Generated number no.

REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no PROPERTY PARCEL/LOT textCAPACITY ML/day MLNUMBER OF PUMPS number no.SEPARATE DUTY/STANDBY PROVISION Yes/No INSTALLATIONDUTY POINT HEAD Metres mDUTY POINT FLOW Litres/sec L/secFLOOR MATERIAL CONSTRUCTIONTYPEWALL MATERIAL CONSTRUCTEDMATERIALROOFMATERIAL CONSTRUCTEDMATERIALPRIMARY ACCESS TYPE ACCESSTYPEINLET TYPE OUTLET/INLET/OVERFLOWTYPEINLET MATERIAL PIPEMATERIALINLET DIMENSION millimetres mm INLET LEVEL (RL) Metres mOUTLET TYPE OUTLET/INLET/OVERFLOWTYPEOUTLET DIMENSION millimetres mm OUTLET MATERIAL ACCESSLIDMATERIALOUTLET LEVEL (RL) Metres mOVERFLOW TYPE OUTLET/INLET/OVERFLOWTYPEOVERFLOW DIMENSION millimetres mm OVERFLOW MATERIAL PIPEMATERIALOVERFLOW LEVEL (RL) Metres mFIRE ALARM Yes/NoACCESS ALARM Yes/No ACCESSTYPEKEY SECURITY LEVEL number no. CONSTRUCTEDMATERIAL

Plan that shows either GA of the asset and/or is specific detail plan

THIS IS THE WASTEWATER PUMP STATION SUMMARY TAB.WASTEWATER PUMP STATION -- WWPS

28/05/2014 22 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 23: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Level 3 Summary Assets

ASSET ID Conquest Generated number no.REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no PROPERTY PARCEL/LOT textTREATMENT CAPACITY ML/day MLPROCESS TYPE textDIMENSION 1 (DIAMETER) Metres mDIMENSION 2 Metres mFLOOR MATERIAL CONSTRUCTEDMATERIALWALL MATERIAL CONSTRUCTEDMATERIALHEIGHT / DEPTH Metres mTOP WATER LEVEL (RL) Metres mSHAPE SHAPEINLET TYPE OUTLET/INLET/OVERFLOWTYPEINLET MATERIAL PIPEMATERIALINLET DIMENSION millimetres mm INLET LEVEL (RL) Metres mOUTLET TYPE OUTLET/INLET/OVERFLOWTYPEOUTLET DIMENSION millimetres mm OUTLET MATERIAL PIPEMATERIALOUTLET LEVEL (RL) Metres mOVERFLOW TYPE OUTLET/INLET/OVERFLOWTYPEOVERFLOW DIMENSION millimetres mm OVERFLOW MATERIAL PIPEMATERIALOVERFLOW LEVEL (RL) Metres mCATHODIC PROTECTED NO/YES ASSET IDACCESSIBILITY ACCESSTYPE

WATER TREATMENT PLANT -- WTP

THIS IS THE WATER TREATMENT PLANT SUMMARY TABPlan that shows either GA of the asset and/or is specific detail plan

28/05/2014 23 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 24: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 Level 3 Summary Assets

ASSET IDConquest Generated number no.

ASSET TAG NUMBER a) P&ID Tag for New Assets number no.ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no PROPERTY PARCEL/LOT textRESERVOIR INSTALLATION INSTALLATIONCAPACITY ML/day MLPROCESS TYPE textDIMENSION 1 (DIAMETER) Metres mDIMENSION 2 Metres mFLOOR LEVEL (RL) Metres mFLOOR MATERIAL CONSTRUCTEDMATERIALWALL MATERIAL CONSTRUCTEDMATERIALHEIGHT / DEPTH Metres mROOF / COVER MATERIAL CONSTRUCTEDMATERIALTOP WATER LEVEL (RL) Metres mSHAPE SHAPEINLET TYPE OUTLET/INLET/OVERFLOWTYPEINLET MATERIAL PIPEMATERIALINLET DIMENSION millimetres mm INLET LEVEL (RL) Metres mOUTLET TYPE OUTLET/INLET/OVERFLOWTYPEOUTLET DIMENSION millimetres mm OUTLET MATERIAL PIPEMATERIALOUTLET LEVEL (RL) Metres mOVERFLOW TYPE OUTLET/INLET/OVERFLOWTYPEOVERFLOW DIMENSION millimetres mm OVERFLOW MATERIAL PIPEMATERIALOVERFLOW LEVEL (RL) Metres mCATHODIC PROTECTED NO/YES ASSET IDACCESSIBILITY ACCESSTYPE

THIS IS THE WASTEWATER TREATMENT PLANT SUMMARY TAB

Plan that shows either GA of the asset and/or is specific detail plan

WASTEWATER TREATMENT PLANT -- WWTP

28/05/2014 24 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 25: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGCOVER RATING ACCESSCOVERTYPEDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL number no.MATERIAL ACCESSLIDMATERIAL

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.ACTUATOR TYPE ACTUATORTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL number no.SERIAL NUMBER number no.MOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASETORQUE SETTINGS CLOSE Kilo newton metres kNmTORQUE SETTINGS OPEN Kilo newton metres kNmTIME TO CLOSE Seconds s

Domain List Name

ACCESS LID -- ACLID ACCESS LID IS FOR ENTRY TO INFRASTRUCTURE OTHER THAN SEWER or STORMWATER CHAMBER , E.G. THEREFOR FOR ACCESS TO TANKS, PITS,HOPPERS, MACHINERY, ETC.

Plan that shows either GA of the asset and/or is specific detail plan

ACTUATOR -- ACTU AN ACTUATOR IS A HYDRAULIC, PNEUMATIC OR ELECTRICAL DEVICE TO ALLOW FOR AUTOMATIC OPERATION OF THE ASSET TO WHICH IT IS ATTACHED (EITHER BY LOCAL SWITCHING OR REMOTE SWITCHING).

Plan that shows either GA of the asset and/or is specific detail plan

GRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

28/05/2014 25 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 26: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.AERATOR TYPE AERATORTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.DISCHARGE FLOW (DUTY) Cubic metres per hour m3/hrMOTOR SIZE Kilowatt kWMOTOR CURRENT Amps AMOTOR VOLTAGE Volts VMOTOR STARTER LOCATION Text chrMOTOR STARTER CURRENT Amps APHASE Number no. MOTORPHASE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGALTERNATOR MANUFACTURER TextDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year dd/mm/yyyyPURCHASE COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITYMODEL Text no.SERIAL NUMBER Text no.SUPPLIERS TextALTERNATOR DESIGN ALTERNATORTYPEBRUSHLESS YES/NOALTERNATOR DESIGN RPM number RPMPRIME OUTPUT AT RATED RPM Kilo Volt Amperes kVA AMMATURE CONNECTION Kilo Volt Amperes kVA ALTERNATOR COOLING textPOWER FACTORFREQUENCY Hertz HzAVAILABLE VOLTAGE FOR DESIGN FREQUENCY

Volts V

AVAILABLE VOLTAGE FOR 3 PHASE OR SINGLE PHASE

Volts V

TESTING FREQUENCY TESTING

ASSET ID Conquest Generated number no.

Plan that shows either GA of the asset and/or is specific detail plan

AUGER -- AUG AN AUGER IS A HYDRAULIC, PNEUMATIC OR

AERATOR -- AERA AN AERATOR IS A MECHANICAL DEVICE THAT INTRODUCES AIR THROUGH AGITATION IN ORDER TO INCREASE DISSOLVED OXYGEN LEVELS. ONLY TO BE USED WHERE AN AERATOR IS MAINTAINED AS A SINGLE AND ENTIRE PIECE OF EQUIPMENT.

ALTERNATOR -- ALT AN ASSET IN THE GENSET UNIT RESPONSIBLE FOR GENERATING ELECTRIC CURRENT FOR USE IN RUNNING ELECTRIC APPLIANCES AND EQUIPMENT

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 26 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 27: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or leave blank

number no.

ASSET TAG NUMBER b) P&ID Sheet no number no.AUGER TYPE AUGERTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL number no.SERIAL NUMBER number no.MOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASE

ELECTRICALLY ACTIVATED SET OF FLIGHTS, OR DRILLING DEVICE THAT USUALLY INCLUDES A ROTATING HELICAL SCREW BLADE, ACTING AS A SCREW CONVEYOR.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 27 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 28: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.AUTO SAMPLER TYPE SAMPLERTPYEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.CAPACITY Litres LSAMPLE NUMBER RANGE number no.MOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.LIGHT TYPE LIGHTTYPEMAST HEIGHT metre mREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.

AUTO SAMPLER -- SAMP THE AUTO SAMPLER PROVIDES THE MEANS TO INTRODUCE A SAMPLE AUTOMATICALLY INTO THE INLETS. MANUAL INSERTION OF THE SAMPLE IS POSSIBLE BUT IS NO LONGER COMMON. AUTOMATIC INSERTION PROVIDES BETTER REPRODUCIBILITY AND TIME OPTIMISATION. Plan that shows either GA of the asset and/or is specific detail plan

AVIATION LIGHTING -- AVRLT THIS FIELD IS FOR INCLUSION WHERE THE LIGHTING IS A MAINTENANCE MANAGED ITEM.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 28 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 29: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.BATTERY TYPE BATTERYTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MAX CURRENT RATING Amps AVOLTAGE Volts V

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.CHARGER TYPE BATTERYCHARGERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.TOTAL INSTALLED CURRENT Amps ATOTAL INSTALLED POWER Kilowatt kWPHASE Number no. MOTORPHASEVOLTAGE Volts V

BATTERY CHARGING UNIT -- CHAR THIS IS DEVICE USED TO PUT ENERGY INTO A SECONDARY CELL OR RECHARGEABLE BATTERY BY FORCING AN ELECTRIC CURRENT THROUGH IT.

Plan that shows either GA of the asset and/or is specific detail plan

BATTERY -- BATT THIS IS AN ENERGY DEVICE INDEPENDENT OF RETICULATED POWER SUPPLY AND OFTEN ABLE TO BE MADE PORTABLE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 29 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 30: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.BELT PRESS TYPE PRESSTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.DUTY number no.TOTAL INSTALLED CURRENT Amps ATOTAL INSTALLED POWER Kilowatt kWPHASE Number no. MOTORPHASEVOLTAGE Volts V

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.BELT PRESS TYPE PRESSTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.SHAFT DIAMETER number mmBEARING RACE DIAMETER number mm

BELT PRESS -- BELT THIS IS ONLY USED IF THE BELT PRESS MAINTENANCE IS MAINTAINED AS A SINGLE AND ENTIRE PIECE OF EQUIPMENT.

Plan that shows either GA of the asset and/or is specific detail plan

BEARINGS -- BEAR THIS IS ONLY USED IF THE BELT PRESS MAINTENANCE IS MAINTAINED AS INDIVIDUAL COMPONENTS, A CHILD ASSET OF BELT PRESS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 30 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 31: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.BLOWER TYPE BLOWERTYPECONTROL TYPE CONTOLLERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSETACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL number no.SERIAL NUMBER number no.NUMBER OF STAGES number no.COOLING METHOD COOLINGMETHODINPUT PRESSURE millimetres water column mmDISCHARGE PRESSURE millimetres water column mmDISCHARGE FLOW (DUTY) Cubic metres per hour m3/hrMOTOR SIZE Kilowatt kWMOTOR CURRENT Amps AMOTOR VOLTAGE Volts VMOTOR STARTER LOCATION Text chrMOTOR STARTER CURRENT Amps APHASE MOTORPHASESPEED (DUTY) revolutions per minute rpmDISCHARGE PIPEWORK DIAMETER millimetre mmDISCHARGE PIPEWORK MATERIAL PIPEMATERIALDISCHARGE PIPEWORK LENGTH metres mDISCHARGE PIPEWORK ISOLATING VALVE Number no.

BLOWER -- BLO A BLOWER IS A MACHINE WHICH CAN INCREASE OR DECREASE AIR/GAS AR AN INCREASED OR REDUCED PRESSURE (VACUUM). THE MECHANICAL INPUT TO THE BLOWER IS PROVIDED BY AN ELECTRIC OR COMBUSTION MOTOR. THIS IS ONLY USED IF THE BLOWER MAINTENANCE IS MAINTAINED AS A SINGLE AND ENTIRE PIECE OF EQUIPMENT. Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 31 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 32: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.BIN HOPPER TYPE BINHOPPERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no DEPTH metres mNOMINAL DIAMETER millimetres mm NOMDIAMETERMATERIAL TYPE CONSTRUCTEDMATERIALCAP TYPE CAPTYPEMAX RATED LOAD Kilograms kgACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.BORE TYPE BORETYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no TOTAL DEPTH OF BORE metres mNOMINAL DIAMETER millimetres mm NOMDIAMETERCASING TYPE CASINGTYPESIZE OF PERFORATIONS millimetres mmPERFORATION DIAMETER NOMDIAMETERPERFORATION LENGTH metres mPERFORATION MATERIAL PIPEMATERIALSURROUND TYPE SURROUNDTYPECAP TYPE CAPTYPECASING GROUTING GROUTINGTYPESWL (STANDING WATER LEVEL) metres reduced level mMAX PUMP INTAKE LEVEL metres mMAX RATED BORE Litres per second L/sACCESSIBILITY ACCESSTYPE

BORE -- BORE A LONG CYLINDRICAL SHAFT USED TO ACCESS UNDERGROUND SOURCE WATER FOR TRANSPORTATION TO THE SURFACE. A BORE AND ITS RESPECTIVE PUMP SHALL BE CONSIDERED AS TWO (2) SEPARATE ASSETS.

Plan that shows either GA of the asset and/or is specific detail plan

BIN HOPPER -- BIN A BIN OR HOPPER IS A STORAGE CONTAINER OR SYSTEM OF CONTAINERS USED TO STORE MATERIALS OFTEN DELIVERED THROUGH A CHUTE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 32 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 33: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.FUNCTION BUILDFUNCTASBESTOS PRESENT YES/NOASBESTOS REGISTER NUMBER number no.REFERENCE DRAWING no.INSTALLATION DATE date dateDESIGN LIFE year no.DESIGN WIND RATING CATEGORY WIND Class no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) MAINTENANCEKEYGPS LOCATION UTM coords no BUILDING DIMENSION 1 Metres mBUILDING DIMENSION 2 Metres mAREA Metres squared m2

EXTERNAL CLADDING MATERIAL CONSTRUCTEDMATERIALROOF CONSTRUCTION CONSTRUCTEDMATERIALWALL CONSTRUCTION CONSTRUCTEDMATERIALFLOOR CONSTRUCTION CONSTRUCTEDMATERIALDOOR CONSTRUCTION CONSTRUCTEDMATERIALWINDOW CONSTRUCTION CONSTRUCTEDMATERIALROOF CONSTRUCTION CONSTRUCTEDMATERIALINTERNAL HEIGHT Metres mRL GROUND LEVEL Metres mRL FLOOR LEVEL Metres mFIRE ALARM SYSTEM NO / or List Asset ID for SystemSECURITY SYSTEM NO / or List Asset ID for SystemLIGHTING TYPE LIGHTTYPEFIXTURES FIXTURESTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.CABLE TYPE CABLEUSEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) MAINTENANCEKEYGPS LOCATION UTM coords no MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.LENGTH mARMOURED YES/NOCORE MATERIAL CABLECOREMATERIALNO. OF CORES Number no.SHEATH MATERIAL CABLESEATHMATERIALACCESSIBILITY ACCESSTYPE

CABLE -- CAB ALL CABLES AND WIRES FOR POWER SUPPLY, POWER DISTRIBUTION, INSTRUMENT SIGNALS AND COMMUNICATIONS. IF NOT RECOGNISED SEPARATELY, CABLES INCLUDE TERMINATION FIELD OUTLET POINTS, JUNCTION BOXES AND CABLE DRAW PITS, DUCTS, CABLE TRAYS ETC. GENERALLY, SEPARATE ASSETS FOR ALL POWER CABLES AND ALL COMMUNICATIONS / INSTRUMENTATION CABLES FOR EACH SITE ARE IDENTIFIED, AND ANCILLARIES E.G. DUCTS CABLE TRAYS, DRAW PITS ARE CONSIDERED EQUALLY SPLIT BETWEEN THE ASSETS.

Plan that shows either GA of the asset and/or is specific detail plan

BUILDING -- BLD A BUILDING INCLUDES FLOOR, WALLS AND ROOF, TOGETHER WITH ALL DOORS, WINDOWS, ATTACHED LIGHTING AND PLUMBING SERVICES (E.G. TOILETS, SHOWERS). INTERNAL CIVIL, MECHANICAL AND ELECTRICAL WORKS ASSOCIATED WITH HOUSED PROCESSES ARE RECOGNISED SEPARATELY.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 33 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 34: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.SYSTEM ELEMENT TYPE CATHODICTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.NORMAL OPERATION RANGE NA or the current.voltage range number no.ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.OWNER/CUSTODIAN Text chrCERTIFICATION EXPIRY DATE date dateLAST INSPECTED date date

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.TYPE CENTIFUGETYPEDATE OF MANUFACTURE date dateREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial PositionMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MOTOR SIZE Kilowatt KWASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPE

CENTRIFUGE -- CENT CENTRIFUGE IS A MECHANICAL DEVICE THAT USES CENTRIFUGAL FORCES TO SEPARATE LIQUIDS FROM SOLIDS.

Plan that shows either GA of the asset and/or is specific detail plan

CATHODIC PROTECTION -- CATHP CATHODIC PROTECTION IS USED TO CONTROL THE CORROSION OF A METAL SURFACE BY MAKING IT THE CATHODE OF AN ELECTROCHEMICAL CELL. A METHOD OF PROTECTION CONNECTS PROTECTED METAL TO A MORE EASILY CORRODED SACRIFICIAL METAL TO ACT AS THE ANODE. Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 34 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 35: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.SYSTEM ELEMENT TYPE FEEDERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.NORMAL OPERATION RANGE number no.ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.SYSTEM ELEMENT TYPE CHAINFLIGHTTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.NORMAL OPERATION RANGE NA or the current voltage range number no.ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPE

CHAIN AND FLIGHT SYSTEM -- CHAIN CHAIN AND FLIGHT (SCRAPER) SYSTEMS ARE GENERALLY USED IN SLUDGE AND SCUM REMOVAL SYSTEMS.

Plan that shows either GA of the asset and/or is specific detail plan

CHEMICAL FEED SYSTEM -- FEED CHEMICAL FEED SYSTEMS ARE A PACKAGE UNIT INCLUDING THE TRANSFER PUMPS, METERING AND VOLUME SENSING SYSTEMS THAT DELIVER A CHEMICAL AT A REQUIRED RATE INTO A PROCESS FLOW.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 35 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 36: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.COMPRESSOR TYPE COMPRESSORTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSETACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.OUTPUT CONTROL CONTOLLERTYPECOMPRESSOR STAGES number no.COOLING METHOD COOLINGMETHODINPUT PRESSURE millimetres water column mmDISCHARGE FLOW (DUTY) Cubic metres per hour m3/hrMOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASECOMPRESSOR SHAFT SPEED RPMCERTIFICATION EXPIRY DATE date dateCERTIFIER Text chrFUEL STORAGE TANK CAPACITY litres LAIR HOSE DIAMETER millimetres mmAIR HOSE LENGTH metres m

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSETACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.

COMPACTOR -- CMPA A COMPACTOR IS A MACHINE OR MECHANISM USED TO REDUCE THE SIZE OF WASTE MATERIAL THROUGH COMPACTION.

Plan that shows either GA of the asset and/or is specific detail plan

COMPRESSOR -- COMP AN AIR COMPRESSOR IS A DEVICE THAT CONVERTS POWER (USUALLY FROM AN ELECTRIC MOTOR OR ENGINE) INTO KINETIC ENERGY BY COMPRESSING AND PRESSURISING AIR. COMPRESSORS TYPICALLY HAVE A HIGH DISCHARGE PRESSURE THAT DELIVERS PRESSURISED GAS TO A RECEIVING VESSEL FOR STORAGE. NOTE SIMILARITY AND DIFFERENTIATION BETWEEN A COMPRESSOR, A BLOWER AND A FAN. AIR CONDITIONING COMPRESSORS ARE RECOGNISED AS AN AIR CONDITIONING ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 36 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 37: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.CONTROLLER TYPE CONTOLLERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSETACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.I / O TO / FROM Text chrPOWER RATING number no.EXPOSURE CLASS EXPOSURECLASS

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.CONVEYOR TYPE CONVEYORTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSETACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.POWER RATING no.PULLEYS SETS no.BELT LENGTH Metres m

CONVEYOR -- CONY A CONVEYOR CONSISTS OF TWO OR MORE PULLEYS, MOTORS AND A SINGLE CONTINUOUS BELT THAT IS ROTATED IN A CONTINUOUS LOOP USED TO TRANSPORT MATERIAL ABOUT A SITE. THIS PARENT LEVEL ASSET SHOULD ONLY BE USED WHERE THE CONVEYOR IS TO BE MAINTAINED AND REPLACED AS A SINGLE UNIT.

Plan that shows either GA of the asset and/or is specific detail plan

CONTROLLER -- CONT A CONTROLLER IS A CHIP, AN EXPANSION CARD, OR A STAND-ALONE DEVICE THAT INTERFACES WITH A PERIPHERAL DEVICE. THIS MAY BE A LINK BETWEEN TWO PARTS OF A COMPUTER (FOR EXAMPLE A MEMORY CONTROLLER THAT MANAGES ACCESS TO MEMORY FOR THE COMPUTER) OR A CONTROLLER ON AN EXTERNAL DEVICE THAT MANAGES THE OPERATION OF (AND CONNECTION WITH) THAT DEVICE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 37 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 38: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.CRANE TYPE CRANETYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.SAFE WORKING LOAD Kilograms kgLIFTING HEIGHT ABOVE GROUND RLTRAVEL MECHANISM Text chrCERTIFICATION NUMBER number no.CERTIFICATION EXPIRY DATE date dateCERTIFIER Text chr

CRANE -- CRNE THIS ASSET TYPE REFERS TO A FIXED LIFTING DEVICE. THESE INCLUDE GANTRIES, DAVITS, AND MONORAILS. THIS DOES NOT INCLUDE PORTABLE VEHICLE DEVICES.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 38 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 39: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.DRYER TYPE DRYERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.DESIGN CAPACITY CUBIC METRES/HOUR m3/hrPOWER RATINGS Kilowatt kwCERTIFICATION NUMBER number no.CERTIFICATION EXPIRY DATE date dateCERTIFIER Text chr

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.COMMUNICATIONS COMMSTYPE

ELECTRONIC DATA CAPTURE -- EDC EDC IS A COMPUTERISED SYSTEM DESIGNED FOR THE COLLECTION OF OPERATIONAL DATA IN AN ELECTRONIC FORMAT FOR TRANSFER TO DATA ARCHIVAL SYSTEMS.

Plan that shows either GA of the asset and/or is specific detail plan

DRYER -- DRYR A DRYER IS A DEVICE WHICH DRAWS IN AIR, COOLS IT AND THEN REHEATS IT SO THAT THE AIR EXPELLED HAS LESS MOISTURE/HUMIDITY. A DRYER IS TYPICALLY USED WITH AN AIR COMPRESSOR TO REMOVE MOISTURE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 39 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 40: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGENGINE MANUFACTURERDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year dd/mm/yyyyCONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEENGINE MANUFACTURER TextMODEL TextSERIAL NUMBER number no.SUPPLIERS TextENGINE DESIGN ENGINETYPEDISPLACEMENT number LPOWER RATING AT RATED SPEED Kilo Volt Amperes kVA ENGINE RPM number RPMCONFIGURATION textDIMMENSIONS (L x W x H) number mmTARE WEIGHT number kgsNUMBER OF CYLINDERS CYLINDERCOOLING SYSTEM COOLINGSYSTEMFUEL SYSTEM FUELSYSTEMFUEL TYPE FUELTYPEFUEL TANK CAPACITY number LFUEL CONSUMPTION rate L/HrOPERATING TIME PER FULL TANK number HRSNOISE PROTECTION decibel dB(A)

ENGINE -- ENG AN ASSET COMPRISING A PRIMARY DRIVE SOURCE (E.G. A DIESEL ENGINE) AND AN ALTERNATOR TO GENERATE ELECTRICAL POWER.WHERE THE UNIT IS NOT OPERATED AND MAINTAINED AS A SINGLE ITEM OF EQUIPMENT, RATHER IS REPRESENTATIVE OF AN ASSET SYSTEM, THEN TREAT AS A PARENT ASSET AND CREATE RELEVANT CHILDREN ASSETS UNDER THIS PARENT FUNCTION.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 40 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 41: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.EMS TYPE EMSTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.SHAPE SHAPEFLOOR MATERIAL CONSTRUCTEDMATERIALWALL MATERIAL CONSTRUCTEDMATERIALINTERNAL WALL PROTECTION PROTECTIONTYPECOVER MATERIAL CONSTRUCTEDMATERIALNO. OF INLET PIPES Number no.NO. OF OUTLET PIPES Number no.LID DIMENSION 1 (DIAMETER) Metres mLID DIMENSION 2 Metres mACCESS LID MATERIAL ACCESSLIDMATERIALRL ACCESS LID Metres mRL CENTRE FLOOR Metres mDEPTH Metres mBENCHING WIDTH millimetres mmINTERNAL ACCESS YES/NOBACKDROP MANHOLE MANHOLEDROPTYPE - IL BACKDROP1 Metres m - IL BACKDROP2 Metres m - IL BACKDROP3 Metres mCONFINED SPACE YES/NOSOIL TYPE SOILTYPETERRAIN SLOPE number no.HEIGHT DATUM Text chrACCESSIBILITY ACCESSTYPE

EMERGENCY STORAGE -- EMS EMERGENCY STORAGE IS AN ASSET USED TO CAPTURE OVERFLOW. THIS CAN INCLUDE CONCRETE STRUCTURES, SPECIFICALLY FOR USE IN ADDITIONAL STORAGE FOR OVERFLOW.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 41 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 42: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.FAN TYPE FANTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION Adopt 1-5 in terms of remaining life class number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ACCESSIBILITY ACCESSTYPEASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.DISCHARGE FLOW (DUTY) Cubic metres per hour m3/hrMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASE

FAN -- FAN A FAN IS A POWERED DEVICE USED TO CREATE FLOW WITHIN A GAS, USUALLY AIR (FANS DIFFER FROM BLOWERS AND COMPRESSORS IN THAT THE DIFFERENCE BETWEEN SUCTION AND DELIVERY PRESSURE IS NORMALLY VERY LOW).

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 42 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 43: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets number no.ASSET TAG NUMBER b) P&ID Sheet no number no.FENCE TYPE FENCETYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA / Asset ID where item firmly affixed to ASSET number no.FENCE MATERIAL CONSTRUCTEDMATERIALFENCE COATING CONSTRUCTEDMATERIALPOST SIZE millimetres mmPOST DISTANCE Metres mFENCE LENGTH Metres mFENCE HEIGHT Metres mGATE HEIGHT Metres mGATE WIDTH Metres mGATE MATERIAL CONSTRUCTEDMATERIALGATE COATING PROTECTIONTYPEAUTOMATIC OPENER TYPE ACTUATORTYPEGATE POST SIZE Metres mEARTHED ELECTRICALLY YES/NOLIGHTING LIGHTTYPEGATE KEY LEVEL KEYLEVELGATE INTERCOMMUNICATIONS TYPE COMMSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.FILTER TYPE FILTERTYPEMEMBRANE/MEDIA TYPE MEDIATYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MEDIA LAST RECHARGED date dateCAPACITY Cubic metres per hour m3/hrFILTER DIMENSION 1 metre mFILTER DIMENSION 2 metre mFILTER DIMENSION 3 metre mINLET PIPE DIAMETER millimetres mmOUTLET PIPE DIAMETER millimetres mm

FILTER -- FILT A FILTER IS USED FOR THE SEPARATION OF SOLIDS FROM FLUIDS (LIQUIDS OR GASES) BY INTERPOSING A MEDIUM THROUGH WHICH ONLY THE FLUID CAN PASS. OVERSIZE SOLIDS IN THE FLUID ARE RETAINED, BUT THE SEPARATION IS NOT COMPLETE; SOLIDS WILL BE CONTAMINATED WITH SOME FLUID AND FILTRATE WILL CONTAIN FINE PARTICLES (DEPENDING ON THE PORE SIZE AND FILTER THICKNESS).

Plan that shows either GA of the asset and/or is specific detail plan

FENCE -- FENC THE FENCE ASSET INCLUDES GATES (AND AUTOMATION EQUIPMENT IF AUTOMATED) AND LOCKS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 43 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 44: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.FIRE EQUIPMENT TYPE FIRETYPEFIRE EQUIPMENT CLASS number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET, CARE REQUIRED TO ENSURE THE TAG IS TO THE MOST RELEVANT BUILDING or FACILITY ASSET LEVELACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.FIRE SERVICES BLOCK PLAN YES/NOFIRE SERVICES INTERFACE MATRIX YES/NOFIRE SERVICES TEST RECORD YES/NOCERTIFICATE OF OCCUPANCY YES/NO

FIRE BRIGADE BOOSTER ASSEMBLY LOCATION GPS and GIS Spatial Position UTM coords no

FIRE PUMP LOCATION GPS and GIS Spatial Position UTM coords no NUMBER OF FIRE PUMPS Number no.SELF CONTAINED BREATHING APPARATUS HOOKER SYSTEM

ENERGYTYPE

FIRE PUMP DUTY L/s @ m head L/s @ mFIRE PUMP/S LAST TEST DATE date dateEQUIPMENT CERTIFICATION EXPIRY DATE date dateEQUIPMENT CERTIFIER Text chrEQUIPMENT HAZARD RATING Text chrEQUIPMENT LAST TEST DATE date date

FIRE FIGHTING EQUIPMENT -- FIREQ THIS IS THE DEDICATED ONSITE FIRE FIGHTING EQUIPMENT USED TO PUT OUT FIRES.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 44 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 45: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.FIRE ALARM TYPE FIREALARMTYPEREPORTS TO Text chrBACKUP ENERGY SOURCE YES/NOREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET, CARE REQUIRED TO ENSURE THE TAG IS TO THE MOST RELEVANT BUILDING or FACILITY ASSET LEVELACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.NUMBER number no.ELEMENT TEST DATE date dateELEMENT TEST ORGANISATION Text chr

ACTIVE FIRE ALARM SYSTEM -- FALRM

THIS IS A DISCRETE ASSET TYPE THAT INCLUDES THE FIRE CONTROL PANEL, SMOKE DETECTORS, HEAT DETECTORS, ALARMS ETC.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 45 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 46: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

PIPE SEGMENT NUMBER Asset ID number no.FITTING TYPE FITTINGTYPENODE NUMBER Asset ID number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chr

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.STORAGE TYPE TANKTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET, CARE REQUIRED TO ENSURE THE TAG IS TO THE MOST RELEVANT BUILDING or FACILITY ASSET LEVELACCESSIBILITY ACCESSTYPENUMBER number no.STORAGE SYSTEMS TEST DATE date dateALARM SYSTEM REPORTING YES/NO TEST ORGANISATION Text chr

FUEL STORAGE SYSTEM -- FULST THIS IS A DISCRETE ASSET TYPE THAT ENABLES THE STORAGE AND CONTROL OF FLAMMABLE FLUIDS OR GASES. THIS INCLUDES THE PRESSURE VESSELS, THE MONITORING AND MEASURING EQUIPMENT.

Plan that shows either GA of the asset and/or is specific detail plan

FITTINGS -- FITT THIS IS A DISCRETE ASSET TYPE THAT IS ONLY USED FOR THE WATER AND SEWERAGE NETWORKS. IT IS USED ONLY WHERE THE FITTING IS TO BE MAINTAINED. OTHERWISE IT IS A TYPE ATTRIBUTE OF A NODE AND THEREFORE DOES NOT REQUIRE A FURTHER ASSET ID.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 46 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 47: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESS TYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.GEAR RATIO number no.COUPLE METHOD COUPLEMETHODMATERIAL CONSTRUCTEDMATERIALPROTECTION PROTECTIONTYPEMOUNTINGS MOUNTINGSTYLEINPUT RPM Revolutions per minute rpmOUTPUT RPM Revolutions per minute rpm

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGGENERATOR TYPE GENERATORTYPEDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.ENGINE SIZE Kilowatt kWKVA RATING Kilo Volt Amperes kVA LOAD BANK INSTALLED YES/NOFUEL TYPE FUELTYPEFUEL TANK CAPACITY Litres LOPERATING TIME PER FULL TANK hours hrTESTING FREQUENCY Text chrdB RATING number no.NOISE PROTECTION YES/NO

GENERATOR SET -- GSET AN ASSET COMPRISING A PRIMARY DRIVE SOURCE (E.G. A DIESEL ENGINE) AND AN ALTERNATOR TO GENERATE ELECTRICAL POWER.WHERE THE UNIT IS NOT OPERATED AND MAINTAINED AS A SINGLE ITEM OF EQUIPMENT, RATHER IS REPRESENTATIVE OF AN ASSET SYSTEM, THEN TREAT AS A PARENT ASSET AND CREATE RELEVANT CHILDREN ASSETS UNDER THIS PARENT FUNCTION.

Plan that shows either GA of the asset and/or is specific detail plan

GEAR BOX -- GBOX A GEAR BOX IS AN ASSET THAT USES GEARS AND GEAR TRAINS TO PROVIDE SPEED AND TORQUE CONVERSIONS FROM A ROTATING POWER SOURCE TO ANOTHER DEVICE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 47 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 48: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) Sewer Segment Number number no.NETWORK SUB-CATCHMENT Relevant Sewer Network Sub-Catchment Tag number/text no.SEWER TYPE SEWERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position , UTM coords no NOMINAL DIAMETER millimetres mm NOMDIAMETERPIPE MATERIAL PIPEMATERIALPIPE LINING CONSTRUCTEDMATETRIALPIPE CLASS PIPEPRESSURECLASSPIPE JOINT METHOD PIPEJOINTTYPEPIPE LENGTH metres mSUBSTANCE CONTAINED INTERNALMEDIAUPSTREAM MANHOLE ASSET ID number no.DOWNSTREAM MANHOLE ASSET ID number no.RL SURFACE UPSTREAM metres mRL SURFACE DOWN STREAM metres mIL PIPE UPSTREAM metres mIL PIPE DOWNSTREAM metres mSOIL TYPE SOILTYPEHEIGHT DATUM DATUMPIPE PROTECTION /WRAPPING TYPE PROTECTIONTYPEBEDDING TYPE/ SUPPORT TYPE BEDDINGSUPPORTTYPEGRADE percent in 100 metres %CATHODIC PROTECTION YES/NOENVELOPER AND TYPE ENVELOPERTYPECCTV RECORD If Yes provide Reference Record Number YES/NODATE OF CCTV date dateACCESSIBILITY ACCESSTYPE

GRAVITY SEWERS -- GSEW THIS ASSET TYPE IS ONLY TO BE USED FOR WASTEWATER SEWERS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 48 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 49: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGMOUNTING TYPE MOUNTINGTYPEINSTALLATION INSTALLATIONTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.CAPACITY litres per second l/sSCREW DIAMETER millimetres mmBRIDGE YES/NOAGITATOR YES/NOMOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWPULLEYS AND DRIVE BELTS YES/NOSIEVE millimetres mmCOVER CONSTRUCTEDMATERIAL

GRINDER -- GRND GRINDER/ MACERATOR IS AN ALL-PURPOSE GRINDING MACHINE CAPABLE OF BREAKING DOWN RAGS, CELLULAR MATERIAL AND GRINDABLE SOLIDS FOUND WITHIN A FLUID FLOW.

Plan that shows either GA of the asset and/or is specific detail plan

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 49 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 50: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGCHAMBER TYPE GRITCHAMBERTYPEDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.CAPACITY litres per second l/sSCREW DIAMETER millimetres mmBRIDGE NO/ if yes list Asset ID NumberAGITATOR NO/ if yes list Asset ID NumberMOTOR CURRENT Amos AMOTOR SIZE Kilowatt kWGRIT PADDLE YES/NOGRIT PADDLE MOTOR NO/ if yes list Asset ID NumberGRIT PADDLE GEARBOX NO/ if yes list Asset ID NumberPULLEYS AND DRIVE BELTS YES/NOGRIT PUMP NO/ if yes list Asset ID NumberFEED PIPE TO GRIT PUMP millimetres mmSUMP PUMP NO/ if yes list Asset ID NumberGRIT CONVEYOR NO/ if yes list Asset ID NumberSIEVE millimetres mmCOVER CONSTRUCTEDMATERIAL

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE date dateCONSTRUCTION COST year no.REPLACEMENT VALUE $ $CRITICALITY $ $CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEGUIDE RAIL MATERIAL CONSTRUCTEDMATERIALGUIDE RAIL SIZE (DIAMETER) millimetres mmGUIDE RAIL SHAPE SHAPEGUIDE RAIL LENGTH Metres m

GRIT REMOVAL -- GITR GRIT REMOVAL IS AN ASSET THAT IS PART OF SEWERAGE PRE-TREATMENT, WHERE THE VELOCITY OF THE INCOMING SEWAGE IS ADJUSTED TO ALLOW THE SETTLEMENT OF SAND, GRIT, STONES, AND BROKEN GLASS. THESE PARTICLES ARE REMOVED BECAUSE THEY MAY DAMAGE PUMPS AND OTHER EQUIPMENT. GRIT CHAMBERS COME IN 3 TYPES: HORIZONTAL GRIT CHAMBERS, AERATED GRIT CHAMBERS AND VORTEX GRIT CHAMBERS.IF NOT OPERATED, MAINTAINED AND REPLACED AS A SINGLE ASSET, TREAT AS PARENT AND CREATE RELEVANT CHILDREN ASSETS UNDER THIS PARENT..

Plan that shows either GA of the asset and/or is specific detail plan

GUIDE RAIL -- GRAIL PUMP GUIDE RAIL IS RECOGNISED AS A SEPARATE ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 50 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 51: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.TYPE HYDRANTTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED PIPE ASSET number no.ASSOCIATED SERVICE CONNECTIONPIPE ASSET

Only complete where hydrant is on a service connection main number no.

ACCESSIBILITY ACCESSTYPEDIAMETER millimetre mm NOMDIAMETERNUMBER OF HEADS number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.DATE OF PRESSURE TEST date datePRESSURE TEST ORGANISATION Text chrDATE OF LAST MAINTENANCE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.TYPE CONTROLPANELFUNCTIONREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MODEL number no.SERIAL NUMBER number no.DATE OF LAST MAINTENANCE

HYDRANT -- HYDN A WATER HYDRANT IS A SPECIAL TYPE OF CONTROLLABLE FITTING PLACED ON TRUNK AND RETICULATION MAINS FOR PROVIDING WATER FOR EMERGENCY USE. THERE ARE TWO SUBTYPES AVAILABLE – HYDRANT (SPRING) AND OFFTAKE. THE ASSET BY DEFINITION INCLUDES ITS COVER BOX. Plan that shows either GA of the asset and/or is specific detail plan

This should be an autofill from CMMS system. Is that possible.

HUMAN INTERFACE TERMINAL -- HITS

A HUMAN (OR OPERATOR) INTERFACE TERMINAL IS A TERMINAL AND CONTROL SYSTEM INTERFACE DEVICE PLACED AT THE EQUIPMENT BEING OPERATED.

Plan that shows either GA of the asset and/or is specific detail plan

This should be an autofill from CMMS system. Is that possible.

28/05/2014 51 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 52: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.HVAC TYPE HVACTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MODEL Text chrSERIAL NUMBER number no.CAPACITY BTU. no.DATE OF LAST MAINTENANCE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.INJECTOR TYPE INJECTORTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED PIPE ASSET number no.ACCESSIBILITY ACCESSTYPEDIAMETER millimetre mm NOMDIAMETERNUMBER OF HEADS number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.SUBSTANCE INJECTED INTERNALMEDIAOPERATION RANGE kPaDOSING RATE L/sDATE OF LAST MAINTENANCE

HEATING VENTILATION AND AIR-CONDITIONING -- HVAC

THE THREE CENTRAL FUNCTIONS OF HEATING, VENTILATING, AND AIR-CONDITIONING ARE INTERRELATED, ESPECIALLY WITH THE NEED TO PROVIDE THERMAL COMFORT AND ACCEPTABLE INDOOR AIR QUALITY WITHIN REASONABLE INSTALLATION, OPERATION, AND MAINTENANCE COSTS. HVAC SYSTEMS CAN PROVIDE VENTILATION, REDUCE AIR INFILTRATION, AND MAINTAIN PRESSURE RELATIONSHIPS BETWEEN SPACES.

Plan that shows either GA of the asset and/or is specific detail plan

This should be an autofill from CMMS system. Is that possible.

INJECTOR -- INJET AN INJECTOR IS A TYPE OF PUMP THAT FORCIBLY INTRODUCES A FLUID OR GAS INTO THE FLOW STREAM OR PROCESS IN A CONTROLLED MANNER.

Plan that shows either GA of the asset and/or is specific detail plan

This should be an autofill from CMMS system. Is that possible.

28/05/2014 52 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 53: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.INSTRUMENT TYPE INSTRUMENTTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.RANGE number no.MEASUREMENT MEASUREMENTTYPEINSTRUMENT METHOD MEASUREMENTMETHODOUTPUT TYPE (ANOLOG / DIGITAL) Text chrI / O LINK Text chrMATERIAL MEASURED INTERNALMEDIAVOLTAGE Volts V

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.LADDER TYPE LADDERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MODEL Text chrSERIAL NUMBER number no.LADDER MATERIAL CONSTRUCTEDMATERIALLOAD LIMITS kilograms kgOWNER/CUSTODIAN Text chrCERTIFICATION EXPIRY DATE date dateLAST INSPECTED date date

INSTRUMENT -- INST INSTRUMENTS INCLUDE DEPTH GAUGES, FLOW METERS, LEVEL GAUGES, LEVEL MONITORING, PH ANALYSERS, SENSORS, TRANSMITTERS, ETC.

Plan that shows either GA of the asset and/or is specific detail plan

LADDERS -- LADD PURPOSE BUILT AND MAINTAINED LADDERS, WALKWAYS OR PLATFORMS THAT ARE MAINTAINED SEPARATE TO AN ASSOCIATED ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 53 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 54: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.LANDSCAPE TYPE LANDSCAPETYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.IRRIGATION SYSTEM IRRIGATIONTYPELANDSCAPE LENGTH Metres mLANDSCAPE WIDTH Metres m

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.LIGHTING TYPE LIGHTTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL number no.SERIAL NUMBER number no.RANGE number no.WATTAGE /LUMENS number no.VOLTAGE Volts V

LANDSCAPING -- LANS A SOFT ASSET USED TO DEFINE LANDSCAPING FEATURES SUCH AS GARDENS AND LAWNS THAT INCUR A COST TO CONSTRUCT AND MAINTAIN.

Plan that shows either GA of the land parcel and its RPL number and/or is specific detail plan of the bed elements.

LIGHTING SYSTEMS -- LIGT THE ELECTRICAL LIGHTING USED TO ILLUMINATE AN ASSET OT ITS SURROUNDS. LIGHTING COULD BE INTERNAL OR EXTERNAL.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 54 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 55: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chr

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.LINER TYPE LINERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrSHAPE SHAPEMAJOR DIMENSION Metre mMINOR DIMENSION Metre mTHICKNESS millimetres mm

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chr

LIGHTNING PROTECTION SYSTEMS -- LTRPROT

A LIGHTNING PROTECTION SYSTEM IS DESIGNED TO PROTECT A STRUCTURE FROM DAMAGE DUE TO LIGHTNING STRIKES BY INTERCEPTING SUCH STRIKES AND SAFELY PASSING THEIR EXTREMELY HIGH CURRENTS TO GROUND. A LIGHTNING PROTECTION SYSTEM INCLUDES A NETWORK OF AIR TERMINALS, BONDING CONDUCTORS, AND GROUND ELECTRODES DESIGNED TO PROVIDE A LOW IMPEDANCE PATH TO GROUND FOR POTENTIAL STRIKES.

Plan that shows either GA of the asset and/or is specific detail plan

LIME SLAKER -- SLAK LIME SLAKERS CONVERT CALCIUM OXIDE INTO CALCIUM HYDROXIDE SLURRY FOR THE INTRODUCTION INTO PLANT PROCESS.

Plan that shows either GA of the asset and/or is specific detail plan

LINER SYSTEMS -- LNR LINER SYSTEMS USED FOR WATER STORAGE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 55 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 56: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGLOAD BANK MANUFACTURER TextDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year dd/mm/yyyyPURCHASE COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.ACCESSIBILITYMODEL Text no.SERIAL NUMBER Text no.SUPPLIERS TextLOAD BANK DESIGN LOADBANKDESIGNSLOAD STEPS RESOLUTION TexTCAPACITY Kilowatt kWVOLTAGE Voltage VFREQUENCY Hertz HzDUTY CYCLE textAMBIENT TEMPERATURE number degreeAIR INTAKE TEMPERATURE number degreeRATING Kilowatt kWTOLERANCE percent %LOAD CONNECTIONS textLOAD STEPS RESOLUTION Voltage VCONTROL PANEL volts alternating current VAC/HzPOWER CONTROL volts alternating current VAC/HzCOOLING SYSTEM COOLINGSYSTEMDIMENSIONS (W x L x H) number mmUNIT WEIGHT number kgTESTING FREQUENCY TESTING

Load Bank -- LBNK AN ASSET IN THE GENSET UNIT, USED TO DEVELOP ELECTRICAL LOAD, APPLIED THE LOAD TO AN ELECTRICAL POWER SOURCE AND CONVERTS OR DISSIPATES THE RESULTANT POWER OUTPUT OF THE SOURCE Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 56 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 57: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets number no.ASSET TAG NUMBER b) P&ID Sheet no number no.MANHOLE TYPE MANHOLETYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no. - ACCESS CONDITION number no. - CHAMBER CONDITION number no. - H2S ATTACK YES/NO - BENCH CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET 1 number no.ASSOCIATED ASSET 2 number no.MAINTENANCE ACCESS DIMENSION1 Metres mMAINTENANCE ACCESS DIMENSION2 Metres mSHAPE SHAPEFLOOR MATERIAL CONSTRUCTEDMATERIALFLOOR TYPE CONSTRUCTEDMATERIALFLOOR LINING CONSTRUCTEDMATERIALWALL MATERIAL CONSTRUCTEDMATERIALWALL TYPE CONSTRUCTEDMATERIALWALL LINING millimetres mmCOVER/LID RATING COVERTYPENO. OF INLET PIPES Number no.NO. OF OUTLET PIPES Number no.OVERFLOW YES/NOLID DIMENSION 1 (DIAMETER) Metres mLID DIMENSION 2 Metres mACCESS LID MATERIAL ACCESSLIDMATERIALRL ACCESS LID Metres mRL CENTRE FLOOR Metres mDEPTH Metres mBENCHING WIDTH millimetres mmINTERNAL ACCESS YES/NOBACKDROP MANHOLE MANHOLEDROPTYPE - IL BACKDROP1 Metres m - IL BACKDROP2 Metres m - IL BACKDROP3 Metres mSOIL TYPE SOILTYPETERRAIN SLOPE percent in 100 m %HEIGHT DATUM DATUMACCESSIBILITY ACCESSTYPE

MANHOLES -- ACMH A MANHOLE IS AN ASSET USED TO ALLOW ACCESS TO SEWER AND STORMWATER MAINS. THERE ARE TWO PRIMARY TYPES OF MANHOLES: STANDARD MANHOLES AND END MANHOLES. A STANDARD MANHOLE IS AN OPENING ALLOWING ACCESS BY OPERATORS OR EQUIPMENT. IT MAY ALSO BE CALLED AN ACCESS HOLE OR MAINTENANCE HOLE. END MANHOLES OCCUR AT THE BEGINNING OF A MAIN HAVING ONLY AN OUTLET MAIN AND NO INLET (OTHER THAN A CUSTOMER SERVICE). END MANHOLES GENERALLY HAVE NO ACCESS LID BUT DO HAVE THE ABILITY TO BE MODIFIED SHOULD THE SEWER LINE BE EXTENDED.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 57 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 58: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.PROTECTION TYPE PROTECTIONTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.APPLICATION METHOD APPLICATIONMETHODMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.THICKNESS millimetres to 1 decimal place mm

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets number no.ASSET TAG NUMBER b) P&ID Sheet no number no.MEDIA TYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESS TYPEMANUFACTURER Text chr

MATERIAL PROTECTION SYSTEM -- MATPROT

A SYSTEM IMPLEMENTED TO PROTECT THE INTEGRITY OF AN ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

MEDIA -- MEDR THIS ASSET PARENT SHOULD ONLY BE USED WHERE THERE IS TO BE MAINTENANCE OF A FILTER MEDIA UNDERTAKEN SEPARATE TO THAT OF THE FILTER UNIT ITSELF I.E. ACTIVATED CARBON FILTERS, PRESSURE SAND ETC. Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 58 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 59: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.METER TYPE METERTYPEMEASURING MEASUREMENTTYPEMETER INFORMATION USE IF METERTYPE Volumetric THEN COMPLETE METERUSETYPE

NUMBER OF SUBORDINATE METERSIF METERUSETYPE SUBMETER THEN COMPLETE WITH Numeric

number number no.

REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED PIPE ASSET number no.PROPERTY IDENTIFIER MATERIAL MEASURED INTERNALMEDIAINSTALLATION TYPE INSTALLATIONACCESSIBILITY ACCESS TYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.RECORDING LOCATION REMOTE/FIXEDNOMINAL DIAMETER millimetres mm NOMDIAMETERFLOW RANGE kLSUPPLY VOLTAGE VOLTAGEANALOGUE RANGE (4 - 20 mA) kLPULSE SETTING LNO. OF DIALS Number no.MINIMUM COUNTER REGISTRATION LMAXIMUM COUNTER REGISTRATION kLCALIBRATION METHOD Text chrDATE LAST CALIBRATED date dateDATE OF LAST MEASUREMENT date dateREADING WHEN INSTALLED number no.READING WHEN REMOVED number no.

METERS -- MET A METER IS AN INSTRUMENT DEVICE USED FOR MEASURING AN ATTRIBUTE AT A PARTICULAR POINT. A METER MAY BE EITHER A CUSTOMER FLOW METER WHICH IS USED TO MEASURE USAGE BY AN INDIVIDUAL CONSUMER, A NETWORK METER WHICH IS USED BY FIELD OPERATIONS TO MEASURE USAGE AT A PARTICULAR LOCATION ON THE NETWORK, OR A PROCESS METER TO MEASURE PROCESS FLOWS AT TREATMENT PLANTS. NOTE MEASURING FLUMES ARE CONSIDERED TO BE FLOW METERS. THE ELECTROMAGNETIC FLOW METERS ARE RECOGNISED TO INCLUDE SENSING HEADS, AMPLIFIERS, DISPLAY AND TRANSMITTING COMPONENTS. FLOW METER ASSET WAS PREVIOUSLY NOT TO INCLUDE 20 MM RESIDENTIAL METERS AS SAME ARE REGISTERED SEPARATELY IN RELATION TO RATING FIELDS) - (AWAITING ADVICE RE PREFERRED PATH, ASSUMING, THESE METERS WILL NOW BE INCLUDED).

Plan that shows either GA of the asset and/or is specific detail plan

Of value if being used to manage meters to individual properties only

28/05/2014 59 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 60: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.MIXER TYPE MIXERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.FLUID TYPE INTERNALMEDIAACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MIXER CONSTRUCTION MATERIAL CONSTRUCTEDMATERIALMOTOR CURRENT Amps AMOTOR SIZE Kilowatt kWMOTOR VOLTAGE Volts VNO. OF BLADES Number no.MIXER BLADE MATERIAL CONSTRUCTEDMATERIALNOMINAL DIAMETER millimetres mm NOMDIAMETEREXTENDED SHAFT Yes / NoLENGTH OF SHAFT Metres mPHASE Number no. MOTORPHASESPEED (DUTY) Revolutions per minute rpm

MIXER -- MXR A DEVICE USED TO MIX A CHEMICAL WITH ANOTHER MEDIA VIA BLENDING OR AGITATION. A MIXER IS AN ASSET THAT CAN BE RECOGNISED AS ONE OR MANY ASSETS. DISCRETION IS NEEDED AS TO WHETHER TO RECOGNISE A MIXER AS A SINGLE ASSET OR AS A MIXER, GEARBOX AND MOTOR. TYPICALLY THE MOTOR AND GEARBOX/MIXER WOULD AT LEAST BE RECOGNISED SEPARATELY AS THEY REQUIRE SEPARATE PLANNED MAINTENANCE WORK ORDERS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 60 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 61: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.MOTOR TYPE MOTORTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MOTOR CONTROLLER YES/NOMOTOR SIZE Kilowatt kWEXPOSURE CLASS Text chrFRAME SIZE Text chrMOUNTING MOUNTINGSTYLEMOTOR CURRENT Amps AFULL LOAD CURRENT Amps ACB TYPE AND RATING Amps AMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASENUMBER OF CORES PER PHASE no.POLES Number no. MOTORPOLESSTART METHOD MOTORSTARTMETHODSPEED (DUTY) Revolutions per minute rpmFREQUENCY Hertz HzMOTOR SPEED AT 50 Hz Revolutions per minute rpmMOTOR CABLE LENGTH Metres mVARIABLE SPEED DRIVE YES/NO - MANUFACTURER Text chr - MODEL Text chr - SERIAL NUMBER number no.

MOTOR -- MOTR A MOTOR IS AN ELECTROMECHANICAL DEVICE THAT CONVERTS ELECTRICAL ENERGY INTO MECHANICAL ENERGY. MOTORS ARE USED FOR ASSETS SUCH AS INDUSTRIAL FANS, BLOWERS AND PUMPS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 61 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 62: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.MOTOR CONTROL TYPE MOTORSTARTMETHODREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MOTOR SIZE Kilowatt kWEXPOSURE CLASS Text chrFRAME SIZE Text chrMOUNTING MOUNTINGSTYLEMOTOR CURRENT Amps AFULL LOAD CURRENT Amps ACB TYPE AND RATING Amps AMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASENUMBER OF CORES PER PHASEPOLES Number no. MOTORPOLESFREQUENCY Hertz Hz

MOTOR CONTROL CENTRE -- MCC A MOTOR CONTROL CENTRE IS A DEVICE OR GROUP OF DEVICES THAT SERVERS TO GOVERN IN SOME PREDETERMINED MANNER THE PERFORMANCE OF AN ELECTRIC MOTOR. A MOTOR CONTROLLER MIGHT INCLUDE A MANUAL OR AUTOMATIC MEANS FOR STARTING AND STOPPING THE MOTOR, SELECTING FORWARD OR REVERSE ROTATION, SELECTING AND REGULATING THE SPEED, REGULATING OR LIMITING THE TORQUE AND PROTECTING AGAINST OVERLOADS AND FAULTS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 62 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 63: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

NODE TYPE NODETYPEASSOCIATED PIPE SEGMENT 1 number no.ASSOCIATED PIPE SEGMENT 2 number no.ASSOCIATED PIPE SEGMENT 3 number no.IF VALVE TYPE NODE, LIST VALVE ID number no.GPS LOCATION GPS and GIS Spatial Position UTM coords no DATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEY

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.PIPE TYPE PIPETYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYINSTALLATION TYPE INSTALLATIONNOMINAL DIAMETER millimetres mm NOMDIAMETERPIPE MATERIAL PIPEMATERIALPIPE LINING CONSTRUCTEDMATETRIALPIPE CLASS PIPEPRESSURECLASSPIPE JOINT METHOD PIPEJOINTTYPEPIPE LENGTH metres mSUBSTANCE CONTAINED INTERNALMEDIAUPSTREAM NODE ASSET IDDOWNSTREAM NODE ASSET IDRL SURFACE UPSTREAM metres mRL SURFACE DOWNSTREAM metres mIL PIPE UPSTREAM metres mIL PIPE DOWNSTREAM metres mSOIL TYPE SOILTYPEHEIGHT DATUM DATUMPIPE PROTECTION /WRAPPING TYPE PROTECTIONTYPEBEDDING TYPE/ SUPPORT TYPE BEDDINGSUPPORTTYPEGRADE percent in 100 metres %CATHODIC PROTECTION YES/NOENVELOPER AND TYPE ENVELOPERTYPEACCESSIBILITY ACCESSTYPE

NODE -- NODE NODES ARE DEFINED FOR NETWORK PIPE SYSTEMS, TO DEFINE THE TERMINAL POINTS OF EACH PIPE SEGMENT. NODES MAY BE VALVES, FITTINGS OR INTERSECTION LOCATIONS WITH OTHER PIPE SEGMENTS IN WHICH CASE THE NODE IS A GIS POSITION.

PIPES-- PIPE A SINGLE SECTION OF CYLINDRICAL SHAPED TUBING THAT CARRIES MATERIAL E.G. WATER, GAS, STEAM, POWDERS ETC. THIS ASSET TYPE IS ONLY TO BE USED WHERE THE PIPE IS LEVEL 5 CHILD ASSET OF PIPEWORK AND VALVE PARENT ASSETS I.E. ONLY WITHIN FACILITIES WHERE THE PIPE IS DELIMITED BY A SIMILAR LEVEL 5 ASSET SUCH AS A VALVE, PUMP OR INSTRUMENT.

Plan that shows either GA of the asset and/or is specific detail plan

Need to use the ASSET ID , and within FACILITIES the nodes are typically VALVES

28/05/2014 63 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 64: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.PREVIOUS PIPE SEGMENT NAME/NUMBER Previous Pipe Segment Name/Number number no.NETWORK SUB-CATCHMENT Relevant Water Network Sub-Catchment Tag number/test no.PIPE SEGMENT TYPE PIPETYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYINSTALLATION TYPE INSTALLATIONNOMINAL DIAMETER millimetres mm NOMDIAMETERPIPE MATERIAL PIPEMATERIALPIPE LINING CONSTRUCTEDMATETRIALPIPE CLASS PIPEPRESSURECLASSPIPE JOINT METHOD PIPEJOINTTYPEPIPE LENGTH metres mSUBSTANCE CONTAINED INTERNALMEDIAUPSTREAM NODE ASSET ID NODE ASSET ID number no.DOWNSTREAM NODE ASSET ID NODE ASSET ID number no.PIPE SEGMENT COVER metres mSOIL TYPE SOILTYPEPIPE PROTECTION /WRAPPING TYPE PROTECTIONTYPEBEDDING TYPE/ SUPPORT TYPE BEDDINGSUPPORTTYPEENVELOPER AND TYPE ENVELOPERTYPEACCESSIBILITY ACCESSTYPE

PIPE SEGMENT -- PIPSGM THIS IS A PARENT ASSET IN THE NETWORK ASSETS WHERE VALVES, METERS, HYDRANTS, SERVICE CONNECTIONS AND STRUCTURES ARE CHILD ASSETS OF THE PIPES.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 64 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 65: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.PLATFORM MATERIAL CONSTRUCTEDMATERIALPLATFORM SUPPORT METHOD MOUNTINGSTYLELOAD LIMITS kilograms kgCERTIFICATION EXPIRY DATE date dateLAST INSPECTED date date

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.POND TYPE PONDTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.CAPACITY kilolitres kLEMBANKMENT MATERIAL CONSTRUCTEDMATERIALTOP OF EMBANKMENT LEVEL (RL) mFLOOR MATERIAL CONSTRUCTEDMATERIALLINING MATERIAL CONSTRUCTEDMATERIALLINING THICKNESS millimetres mmSHAPE SHAPEDIMENSION 1 (DIAMETER) Metres mDIMENSION 2 Metres mHEIGHT / DEPTH Metres mEMBANKMENT GRADE percent in 100 m %INLET LEVEL (RL) mINLET DIAMETER millimetres mmOUTLET TYPE OUTLET/INLET/OVERFLOWTYPEOUTLET LEVEL (RL) mOUTLET DIMENSION millimetres mmOVERFLOW TYPE OUTLET/INLET/OVERFLOWTYPEOVERFLOW LEVEL (RL) Metres mOVERFLOW DIMENSION millimetres mmWAVEBAND EDGE PROTECTION MATERIAL CONSTRUCTEDMATERIALAERATION YES/NO

POND / LAGOON -- POND POND OR LAGOON IS A SPECIFIC EARTH EMBANKMENT SUPPORTED RESERVOIR TYPE FOR STORAGE.

Plan that shows either GA of the asset and/or is specific detail plan

PLATFORMS -- PLAT PURPOSE BUILT AND MAINTAINED PLATFORMS THAT ARE MAINTAINED SEPARATE TO AN ASSOCIATED ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 65 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 66: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.POWER SUPPLY TYPE ENERGYTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPELOT NUMBER number no.CLOSEST POWER POLE NUMBER number no.POWER SUPPLY MAX CURRENT CAPACITY amps AINPUT VOLTAGE Volts VOUTPUT VOLTAGE Volts V415 VOLTS MANUFACTURER Text chr415 VOLTS MODEL Text chr415 VOLTS SERIAL NUMBER number no.415 VOLTS ERGON ACCOUNT NUMBER number no.240/12 VOLT DC MANUFACTURER Text chr240/12 VOLT DC MODEL Text chr240/12 VOLT DC SERIAL NUMBER number no.240 VOLTS ERGON ACCOUNT NUMBER number no.

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.PLC TYPE PLCTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.SCAN TIME Minutes to 1 decimal place minNO. ANALOGUE INPUT Number no.NO. ANALOGUE OUTPUT Number no.NO. DIGITAL INPUT Number no.NO. DIGITAL OUTPUT Number no.HUMAN MACHINE INTERFACE Number no.COMMUNICATION PROTOCOL COMMSTYPEPROGRAMMING PROTOCOL COMMSTYPE

POWER SUPPLY -- PSUPP A POWER SUPPLY IS AN ASSET THAT SUPPLIES ELECTRIC POWER TO AN ELECTRICAL LOAD. A POWER SUPPLY CONTROLS THE OUTPUT VOLTAGE OR CURRENT TO A SPECIFIC VALUE; THE CONTROLLED VALUE IS HELD NEARLY CONSTANT DESPITE VARIATIONS IN EITHER LOAD CURRENT OR THE VOLTAGE SUPPLIED BY THE POWER SUPPLY'S ENERGY SOURCE. This ASSET TYPE would be expected to include UPS.

Plan that shows either GA of the asset and/or is specific detail plan

PROGRAMMABLE LOGIC CONTROLLER -- PLC

PROGRAMMABLE LOGIC CONTROLLER (PLC) IS AN ELECTRICAL DEVICE THAT WHEN CONNECTED TO AN ASSET PROVIDES A CONTROL FUNCTION WHICH INITIATES A DESIRED OPERATION. THE PLC IS TYPICAL LOCATED WITHIN A CONTROL SYSTEM.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 66 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 67: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.PUMP TYPE PUMPTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMANUFACTURER CURVE NO. number no.MODEL number no.SERIAL NUMBER number no.STAGES number no.PUMP MASS Kilograms kgPUMP MOUNTING MOUNTINGSTYLEPUMP SPEED HzIMPELLER - TYPE IMPELLERTYPE - MANUFACTURER Text chr - MODEL Text chr - SERIAL NUMBER number no. - DIAMETER millimetres mm - MATERIAL CONSTRUCTEDMATERIAL - PROTECTION PROTECTIONTYPE - NUMBER number no.PUMP HOUSING MATERIAL CONSTRUCTEDMATERIALSTATOR HOUSING MATERIAL CONSTRUCTEDMATERIALSHAFT MATERIAL CONSTRUCTEDMATERIALSHAFT SEALING CONSTRUCTEDMATERIALCAPACITY (DUTY) Litres per second L/sHEAD (DUTY) Metres mSHUT OFF HEAD Metres mDUTY / STANDBY YES/NOOPERATING POINT (1 PUMP) Litres per second at Metre L/s@mOPERATING POINT (2 PUMPS) Litres per second at Metre L/s@mGUIDE RAIL SIZE millimetres mmSHAPE OF GUIDE RAILS SHAPENUMBER OF GUIDE RAILS PER PUMP number no.INLET DIAMETER millimetres mmOUTLET DIAMETER millimetres mmDISCHARGE STYLE (OFFSET / CENTRE)MOTOR - INCLUDED YES/NO - MANUFACTURER Text chr - MODEL Text chr - SERIAL NUMBER number no. - CONTROLLER YES/NO - SIZE / RATED POWER Kilowatt kWMOTOR CURRENT Amps AFULL LOAD CURRENT Amps APEDESTAL SIZE millimetres mmPEDESTAL MATERIAL CONSTRUCTEDMATERIAL

PUMP -- PMP PUMPS CAN BE RECOGNISED AS A SINGLE ASSET OR AS SEPARATE PUMP AND MOTOR ASSETS. PUMP SETS WITH A MOTOR POWER RATING OF LESS THAN 25 KW OR MOTORS THAT ARE NOT PHYSICALLY SEPARATED FROM THE PUMP FOR IDENTIFICATION, MAINTENANCE OR ROTATION PURPOSES ARE RECOGNISED AS A SINGLE ASSET. ALL OTHER PUMP SETS ARE RECORDED AS A SEPARATE PUMP AND MOTOR ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 67 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 68: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.RADIO TYPE RADIOTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.FREQUENCY Hertz HzSIZE number no.TELEMETRY PROTOCOL TELEMETRYTYPEPOWER TYPE ENERGYTYPEACCESSIBILITY ACCESS TYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.ASSOCIATED ASSET number no.FREQUENCY Hertz HzSIZE number no.POWER TYPE ENERGYTYPEDIGITAL/STATUS INPUTS number no.ANALOGUE INPUTS number no.DIGITAL/CONTROL OUTPUTS number no.ANALOGUE OUTPUTS number no.COMMUNICATIONS PROTOCOL COMMSTYPEINTELLIGENT END DEVICE (IED) YES/NOTELEMETRY PROTOCOL TELEMETRYTYPEACCESSIBILITY ACCESSTYPE

RADIO -- RAD A RADIO IS AN ASSET THAT USES WIRELESS TRANSMISSION OF SIGNALS THROUGH FREE SPACE BY ELECTROMAGNETIC RADIATION OF A FREQUENCY SIGNIFICANTLY BELOW THAT OF VISIBLE LIGHT, IN THE RADIO FREQUENCY RANGE.

Plan that shows either GA of the asset and/or is specific detail plan

REMOTE TERMINAL / TELEMETRY UNIT -- RTU

A REMOTE TERMINAL UNIT (RTU) IS A MICROPROCESSOR-CONTROLLED ELECTRONIC DEVICE THAT INTERFACES OBJECTS IN THE PHYSICAL WORLD TO A DISTRIBUTED CONTROL SYSTEM OR SCADA (SUPERVISORY CONTROL AND DATA ACQUISITION) SYSTEM BY TRANSMITTING TELEMETRY DATA TO A MASTER SYSTEM AND BY USING MESSAGES FROM THE MASTER SUPERVISORY SYSTEM TO CONTROL CONNECTED OBJECTS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 68 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 69: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.EXISTING SEWER BRANCH NAME (ALIAS) Only complete if relevant text chrNETWORK SUB-CATCHMENT Relevant Sewer Network Sub-Catchment Tag number/text no.SEWER TYPE SEWERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.CCTV RECORD If Yes provide Reference Record Number YES/NODATE OF CCTV date dateMAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYNOMINAL DIAMETER millimetres mm NOMDIAMETERPIPE MATERIAL PIPEMATERIALPIPE LINING CONSTRUCTEDMATETRIALPIPE CLASS PIPEPRESSURECLASSPIPE JOINT METHOD PIPEJOINTTYPEPIPE LENGTH metres mINSTALLATION TYPE INSTALLATIONTYPEUPSTREAM ISOLATION VALVE ASSET ID. number no.DOWNSTREAM ISOLATION VALVE ASSET ID.

number no.

DOWNSTREAM MANHOLE ASSET ID number no.RL SURFACE UPSTREAM metres mRL SURFACE DOWN STREAM metres mIL PIPE UPSTREAM metres mIL PIPE DOWNSTREAM metres mSOIL TYPE SOILTYPEHEIGHT DATUM DATUMPIPE PROTECTION / WRAPPING TYPE PROTECTIONTYPEBEDDING TYPE / SUPPORT TYPE BEDDINGSUPPORTTYPEGRADE percent %CATHODIC PROTECTION YES/NOENVELOPER AND TYPE ENVELOPERTYPEACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.REFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ROAD WIDTH Metres mLENGTH Metres mAREA Metres squared m2SURFACE ROADSURFACESUB-SURFACE/SUBGRADE CLASS SUBGRADETYPEDRAINAGE TYPE DRAINAGETYPEKERB YES/NOMAXIMUM LOAD tonnes

ROAD / PARKING AREA -- ROAD A PREPARED SURFACE THAT IS SUITABLE FOR THE PASSAGE OF VEHICLES. THIS INCLUDES ACCESS ROADS TO PUMP STATIONS AND BUILDINGS.

Plan that shows either GA of the asset and/or is specific detail plan

Plan that shows either GA of the asset and/or is specific detail plan

Only complete the relevant field

RISING SEWER MAINS -- RSEW THIS ASSET TYPE IS ONLY APPLIED TO RISING SEWER MAINS WHETHER LOW PRESSURE, SMALL DIAMETER OR NOT.

28/05/2014 69 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 70: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.EQUIPMENT TYPE SAFETYEQUIPMENTTYPEREFERENCE USER MANUAL Text chrDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.PURCHASE COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.ASSOCIATED ASSET number no.OPERATIONAL LIMITS/RANGE number no.OWNER/CUSTODIAN Text chrINSTALLATION TYPE INSTALLATIONCERTIFICATION EXPIRY DATE date dateLAST TESTED date dateACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSETHUMAN-MACHINE INTERFACE DEVICE number no.REMOTE TERMINAL UNITS number no.PROGRAMMABLE LOGIC CONTROLLER number no.REPORTS TO Text chrMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.SOFTWARE Text chrPOWER SOURCE ENERGYTYPEINSTALLATION TYPE INSTALLATIONACCESSIBILITY ACCESSTYPE

SAFETY EQUIPMENT -- SAFEQ ASSETS HAVE A PRIMARY PURPOSE BEING ABLE TO ASSIST SAFE WORK. USES INCLUDE FALL PROTECTION, SAFETY CHAINS, GAS DETECTORS, SCBA AND MASKS. SAFETY EQUIPMENT IS TO BE MAINTAINED AS A SINGLE ASSET.

SCADA -- SCDA SCADA (SUPERVISORY CONTROL AND DATA ACQUISITION) IS AN INDUSTRIAL CONTROL SYSTEM (ICS), WHICH IS A COMPUTER CONTROLLED SYSTEM THAT MONITORS AND CONTROLS INDUSTRIAL PROCESSES THAT EXIST IN THE PHYSICAL WORLD. SCADA SYSTEMS ARE USED FOR LARGE SCALE PROCESSES THAT CAN INCLUDE MULTIPLE SITES, AND LARGE DISTANCES. This tab is to fully completed where there are no maintainable Level 5 assets associated with this Level 4 asset, otherwise do not use.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 70 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 71: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.EQUIPMENT TYPE SCALETYPEREFERENCE USER MANUAL DATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.PURCHASE COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.ASSOCIATED ASSET number no.OPERATIONAL LIMITS/RANGE kg/TonnesOWNER/CUSTODIAN Text chrINSTALLATION TYPE INSTALLATIONCERTIFICATION EXPIRY DATE date dateLAST TESTED date dateACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.SCREEN TYPE SCREENTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.CLEANING METHOD CLEANINGMETHODHYDRAULIC CAPACITY Cubic metres per hour m3/hrMOTOR SIZE Kilowatt kWMOTOR CURRENT Amps AMOTOR VOLTAGE Volts VPHASE Number no. MOTORPHASESCREEN SIZE millimetres mmACCESSIBILITY ACCESSTYPE

SCREEN / SIEVE / STRAINER -- SCR A SCREEN, SIEVE OR STRAINER IS AN ASSET WHICH THE FILTRATION ELEMENTS ARE A MESH, NET OR BARS THAT CAN BE MECHANICALLY CLEANED TO RESTORE FULL PERFORMANCE. SIEVES DO NOT USE FILTRATION MEDIA (E.G. MECHANICALLY RAKED TRASH SCREEN, AUTOMATIC BACKFLUSH WEDGE WIRE SCREEN, Y-STRAINER). A SCREEN IS A COURSE STRAINER.

Plan that shows either GA of the asset and/or is specific detail plan

SCALES -- SCAL SCALES ARE UTILISED FOR THE WEIGHING OF CHEMICAL PRIOR TO MIXING WITHIN THE PROCESS. USE THIS WHEN THE SCALES ARE MAINTAINED AS A SINGLE ASSET RATHER THAN WITHIN THE CHEMICAL DOSING SYSTEM.

28/05/2014 71 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 72: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.SYSTEM TYPE SECURITYSYSTEMTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.NO. ACCESS READERS number no.NO. CCTV CAMERAS number no.NO. INFRARED MOVEMENT SENSORS number no.NO. ZONES number no.NO. INTERCOMS number no.NO. ALARMS number no.CENTRAL CONTROL PANEL ASSET ID number no.KEY LEVEL number no.

ASSET ID Conquest Generated number no.EXISTING SEWER BRANCH NAME (ALIAS) Only complete if relevant text chrSUBURB Post Code number no.CONNECTION TYPE CONNECTIONTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYASSOCIATED PIPE SEGMENT NUMBER number no.ASSOCIATED VALVE ASSET 1

Only complete where the Valve has been identified as a MMI. number no.

ASSOCIATED VALVE ASSET 2 Only complete where the CONNECTION TYPE is 'RIDR' . number no.ASSOCIATED SERVICE CONNECTION PIPE Only complete where the CONNECTION TYPE is 'RIDR' . number no.ASSOCIATED METER ASSET If connection type multi only list the Master Meter ID. number no.ASSOCIATED SEWER ASSET Only complete where CONNECTIONTYPE is "SEW" number no.PROPERTY 1 IDENTIFIER Parcel/Lot number Text chrPROPERTY 2 IDENTIFIER Parcel/Lot number (Leave blank for sewer SCONN) Text chrLENGTH metres mMATERIAL CONSTRUCTEDMATERIALNOMINAL DIAMETER millimetres mm NOMDIAMETER ISOLATING VALVE YES/NOCONNECTION CHAMBER YES/NOACCESSIBILITY ACCESSTYPE

SERVICE CONNECTION PIPE -- SCONN A SERVICE CONNECTION PIPE IS THE ASSET THAT CONNECTS THE WATER MAINS OR SEWER MAINS TO THE SERVICE POINT. THE WATER SERVICE PIPE DOES NOT INCLUDE THE PIPE CONNECTING THE CUSTOMER’S HOUSE TO THE SERVICE POINT OF THE CUSTOMER'S SUBMETER TO THE MASTER METER. NOTE: THE SERVICE PIPE WILL ALWAYS HAVE AN UPSTREAM NODE AS THE MAINCOCK VALVE ON THE PARENT PIPE SEGMENT , YET ONLY NEED TO RECORD THE PIPE SEGMENT UNLESS THE MAINCOCK VALVE IS A MAINTENANCE MANAGED VALVE WITH AN ASSIGNED ASSET ID. THE DOWNSTREAM NODE IS THE CUSTOMER METER, BEING THE TERMINAL POINT OF GRC OWNERSHIP, WITH THE EXCEPTION BEING FOR STRATA-TITLED DEVELOPMENT WHERE THE SERVICE PIPE FROM THE MASTER METER TO SUBORDINATE METERS IS NOT A GRC ASSET. THE SEWER CONNECTION EXTENDS FROM THE COLLECTION SEWER TO THE HOUSE JUNCTION PIT JUMP UP.

SECURITY SYSTEM -- SECSY A SECURITY SYSTEM IS AN ELECTRONIC SYSTEM USED TO MONITOR AN ASSET AND RAISE AN ALARM WHEN A PERSON/S ATTEMPT TO ENTER WITHOUT CLEARANCE.

Plan that shows either GA of the asset and/or is specific detail plan

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 72 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 73: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.SOFTWARE TYPE SOFTWARETYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSETMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.ASSOCIATED ASSET number no.

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no STANDPIPE NUMBER number no.

METER NUMBER/ASSOCIATED METER ASSET Are meters being treated as single or a class of asset by size and function. number no.

BACKFLOW PREVENTION YES/NOBACKFLOW PREVENTION ASSET NO. number no.OUTLET SIZE millimetres mmAUTOMATIC YES/NO

SOFTWARE -- SOFT THE SOFTWARE ASSET INCLUDES COMPUTER SOFTWARE FOR OFFICE, PC’S, BUSINESS AND COMMUNICATIONS DRIVERS. THIS ASSET SPECIFICALLY EXCLUDES PLC.

Plan that shows either GA of the asset and/or is specific detail plan

STANDPIPE -- STNDPIPE A STANDPIPE IS AN ASSET THAT IS USED TO REFILL WATER TRUCKS AND OTHER VEHICLES (USE THIS PARENT WHEN THE STANDPIPE IS TO BE TREATED AS A SPECIAL TYPE OF BULK FLOW METERING SYSTEM ASSET). Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 73 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 74: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.STRUCTURE TYPE STRUCTURETYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no.ASSOCIATED ASSETASSOCIATED PIPE SEGMENT NO.CONSTRUCTED MATERIAL CONSTRUCTEDMATERIALSTRUCTURE LINING / PROTECTION PROTECTIONTYPEVERMIN PROTECTION YES/NOSHAPE SHAPEDIMENSION 1 (DIAMETER / LENGTH) Metres mDIMENSION 2 (WIDTH) Metres mHEIGHT / DEPTH Metres mINSTALLATION INSTALLATIONACCESS COVER MATERIAL ACCESSLIDMATERIALCOVER TYPE COVERTYPEACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

SERVICE CONNECTION PIPE ASSET NO. number no.SUB METER TYPE SUBMETERTYPE

NUMBER OF SUBORDINATE METERS IF NOT Master Meter THEN COMPLETE WITH Numeric number number no.

DATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYASSOCIATED PIPE ASSET number no.

PROPERTY IDENTIFIER Of value if being used to manage meters to individual properties

onlynumber no.

UNIT, TENANT, TITLE IDENTIFIERonly complete for where SUBMETERTYPE is 'subordinate', not

'MASTER'.number no.

INSTALLATION TYPE INSTALLATIONACCESSIBILITY ACCESSTYPEMANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.MINIMUM COUNTER REGISTRATION LMAXIMUM COUNTER REGISTRATION kLCALIBRATION METHOD Text chrDATE LAST CALIBRATED date dateDATE OF LAST MEASUREMENT date dateREADING WHEN INSTALLED number no.READING WHEN REMOVED number no.

STRUCTURE -- STRU THIS ASSET TYPE HAS BEEN DEFINED TO REFER TO STRUCTURAL ASSETS THAT ARE NOT BUILDINGS, CHAMBERS, MANHOLES, TANKS, WALKWAYS, ROADS, LADDERS OR FENCES WHICH EACH HAVE THEIR OWN ASSET CATEGORY. EXAMPLES OF STRUCTURES COULD INCLUDE BRIDGES, MONOPOLES, LATTICE TOWERS, GUIDE POLES (THE SEWER NETWORK RECOGNISES PIERS AND CONCRETE STOPS AS STRUCTURES).

Plan that shows either GA of the asset and/or is specific detail plan

SUB-METERS -- SUBM A SUB-METER IS A CUSTOMER FLOW METER WHICH IS USED TO MEASURE USAGE BY AN INDIVIDUAL CONSUMER THAT IS LOCATED WITHIN A MULTI-RESIDENTIAL OR COMMERCIAL, INDUSTRIAL LAND PARCEL. TYPICAL SITES INCLUDE UNITS, APARTMENT GROUPS, ETC.

Either field but not both. If structure is in water network list the pipe segment, other the associated asset.

number no.

28/05/2014 74 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 75: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.INPUT VOLTAGE Volts VOUTPUT VOLTAGE Volts VEXPOSURE EXPOSURECLASSNO. OF PANELS Number no.ENCLOSURE MATERIAL CONSTRUCTEDMATERIALENCLOSURE MATERIAL COATING PROTECTIONTYPEFIRE CONTROL / SUPPRESSION TYPE YES/NOSIZE Kilowatt kWACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.EXPOSURE EXPOSURECLASSNO. OF PANELS Number no.ENCLOSURE MATERIAL CONSTRUCTEDMATERIALENCLOSURE MATERIAL COATING PROTECTIONTYPEFIRE CONTROL / SUPPRESSION TYPE YES/NOSIZE Kilowatt kWACCESSIBILITY ACCESSTYPE

SWITCHBOARD -- SWBRD SWITCHBOARD ASSET CAN ALSO BE REFERRED TO AS A MOTOR CONTROL CENTRE (MCC). COMPONENTS OF SWITCHBOARDS ARE RECOGNISED AS SEPARATE ASSETS E.G. CIRCUIT BREAKERS, STARTERS, ELECTRICAL FILTERS, POWER FACTOR CORRECTION UNITS, CONTROLLERS, PLC’S, RADIOS AND LOCAL POWER DISTRIBUTION.

Plan that shows either GA of the asset and/or is specific detail plan

SUBSTATION -- SUBS A POWER SYSTEM UTILISED TO TRANSFORM VOLTAGE FROM LOW TO HIGH OR VICE VERSA.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 75 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 76: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.TANK TYPE TANKTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSETCAPACITY Metres cubed m3

INTERNAL MATERIAL INTERNALMEDIATANK INSTALLATION TYPE INSTALLATIONDIMENSION 1 (DIAMETER) Metres mDIMENSION 2 Metres mFLOOR MATERIAL CONSTRUCTEDMATERIALFLOOR LEVEL (RL) Metres mWALL MATERIAL CONSTRUCTEDMATERIALROOF SHEETING / LID MATERIAL CONSTRUCTEDMATERIALROOF LEVEL (RL) Metres mROOF SUPPORT STRUCTURE CONSTRUCTEDMATERIALTANK EXTERNAL COATING PROTECTIONTYPEHEIGHT / DEPTH Metres mINLET DIMENSION millimetres mmINLET MATERIAL PIPEMATERIALINLET LEVEL (RL) Metres mOUTLET DIMENSION millimetres mmOUTLET MATERIAL PIPEMATERIALOUTLET LEVEL (RL) millimetres mmOVERFLOW TYPE OUTLET/INLET/OVERFLOWTYPEOVERFLOW DIMENSION millimetres mmOVERFLOW MATERIAL PIPEMATERIALOVERFLOW LEVEL (RL) Metres mLID MATERIAL CONSTRUCTEDMATERIALLID LEVEL (RL) Metres mNATURAL SURFACE LEVEL (RL) Metres mACCESSIBILITY ACCESSTYPE

TANK -- TNK THIS ASSET TYPE REFERS TO ALL TYPES OF NON-PRESSURISED TANKS, INCLUDING HOLDING TANKS, SUMPS, SILOS ETC. RESERVOIRS AND PONDS/LAGOONS ARE CONSIDERED AS A SEPARATE ASSET TYPE.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 76 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 77: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.TELEMETRY TYPE TELEMETRYTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.PHONE NUMBER number no.RANGE SETTING number no.PULSE SETTING number no.REPORTS TO (LOCATION/ASSET) number no.ACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.TRANSFORMER TYPE TRANSFORMERTYPEREFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.KVA RATING Kilo Volt Amperes kVA PRIMARY VOLTAGE Volt VSECONDARY VOLTAGE Volt VACCESSIBILITY ACCESSTYPE

TELEMETRY -- TELE TELEMETRY IS THE WIRELESS TRANSMISSION AND RECEPTION OF MEASURED QUANTITIES FOR THE PURPOSE OF REMOTELY MONITORING ENVIRONMENTAL CONDITIONS OR EQUIPMENT PARAMETERS.

Plan that shows either GA of the asset and/or is specific detail plan

TRANSFORMER -- TRANS A TRANSFORMER IS A STATIC ELECTRICAL DEVICE THAT STEPS UP AND DOWN THE VOLTAGE OF A POWER SUPPLY BY TRANSFERRING ENERGY BY INDUCTIVE COUPLING BETWEEN ITS WINDING CIRCUITS.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 77 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 78: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEPOWER SUPPLY MAX CURRENT CAPACITY amps AINPUT VOLTAGE Volts VOUTPUT VOLTAGE Volts VBATTERY CAPACITY Amp hours AhrMAXIMUM SUPPLY DURATION Hours hr

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPE

UNINTERRUPTIBLE POWER SUPPLY -- UPS

A UPS PROVIDES PROTECTION POWER SUPPLY TO AN ELECTRICAL LOAD UNDER POWER FAILURE/BLACKOUT. A POWER SUPPLY CONTROLS THE OUTPUT VOLTAGE OR CURRENT TO A SPECIFIC VALUE; THE CONTROLLED VALUE IS HELD NEARLY CONSTANT DESPITE VARIATIONS IN EITHER LOAD CURRENT OR THE VOLTAGE SUPPLIED BY THE POWER SUPPLY'S ENERGY SOURCE.

Plan that shows either GA of the asset and/or is specific detail plan

UV LAMP CLEANING UNIT -- UVCLR A UV LAMP CLEANING UNIT IS A DEVICE THAT PERIODICAL AND AUTOMATICALLY CLEANS THE UV LAMPS (ONLY USE IF UNIT IS MAINTAINED SEPARATE TO THE UV DOSING UNIT).

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 78 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 79: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.ACCESSIBILITY ACCESSTYPEPOWER RATING Kilowatts kWDOSE INTENSITY Mega joules/square cm MJ/cm2MAX THROUGHPUT Litres/sec L/s

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.POWER RATING Kilowatts kWDOSE INTENSITY RATINGS Mega joules/square cm MJ/cm2ACCESSIBILITY ACCESSTYPE

UV DOSING UNIT -- UVDOS A UV DOSING UNIT IS A DEVISE THAT EMITS A MEASURED DOSE OF UV LIGHT ACROSS A STREAM OF WATER DESTROYING MICROORGANISMS THAT EXIST IN WATER. This ASSET is for use at level 4 where there are no lower level maintainable assets. Plan that shows either GA of the asset and/or is specific detail plan

UV LAMPS -- UVLMP A UV LAMP IS THE SYSTEM OF CREATING ENERGY FOR FOCUS INTO THE FLUID FLOW PATH (ONLY USE IF UNIT IS MAINTAINED SEPARATE TO THE UV DOSING UNIT).

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 79 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 80: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.VALVE TYPE VALVETYPEREFERENCE DRAWINGVALVE FUNCTION VALVEFUNCTIONBACKFLOW VALVE TYPE Only complete for backflow valves. VALVENONRETURNTYPEIF BACKFLOW, DATE CERTIFICATION EXPIRES

date date

DATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MODEL number no.SERIAL NUMBER number no.BODY MATERIAL VALVEMATERIALFLOW RESTRICTOR MATERIAL VALVEMATERIALNOMINAL DIAMETER millimetres mm NOMDIAMETERPRESSURE RATING kilopascals kPaVALVE COATING PROTECTIONTYPEINSTALLATION CONFIGURATION INSTALLATIONACTUATION VALVEACTUATIONCLOCKWISE CLOSING CLOCKWISECLOSINGNO. OF TURNS TO CLOSE number no.SEAT MATERIAL CONSTRUCTEDMATERIALSTEM MATERIAL VALVEMATERIALVALVE POSITION STATUS VALVESTATUSRISING STEM YES/NOINSTALLATION INSTALLATIONACCESSIBILITY ACCESSTYPEPILOT SET POINT NA/ or Setting in kPa

VALVE -- VAL A DEVICE USED FOR CONTROLLING AND ISOLATING THE FLOW OF A LIQUID, GAS OR STEAM BY ISOLATION, REGULATION AND PREVENTION OF A RETURN FLOW. A VALVE CAN BE MANUALLY OPERATED OR ACTUATOR CONTROLLED. SEPARATE ASSET CATEGORIES HAVE BEEN DEFINED FOR AIR VALVES, CONTROL VALVES, NON RETURN VALVES, BACKFLOW PREVENTION VALVES AND PENSTOCKS. ISOLATION, STOP, SCOUR AND BOUNDARY VALVES SHOULD ALL BE RECOGNISED AS VALVE ASSET TYPE. IF A VALVE HAS AN ACTUATOR, THEN BY DEFINITION, THE ACTUATOR AND VALVE MUST BOTH BE RECOGNISED. A SOLENOID AND HYDRAULIC PILOT ARE BOTH TYPES OF ACTUATORS, BUT NEEDN'T BE RECOGNISED SEPARATELY. BY DEFINITION ACTUATOR IS INCLUDED IN THE VALVEACTIVATON ATTRIBUTE AND AN ASSET RECOGNITION RULE THAT IF THE VALVE IS ACTUATED, A SEPARATE ASSET SHOULD BE RECOGNISED TO PICK UP MORE ATTRIBUTES.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 80 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 81: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.VENT TYPE VENTTYPEIF ODOUR CONTROLLED, TYPE OTHERWISE NA

ODOURCONTROLTYPE

REFERENCE DRAWINGDATE OF MANUFACTURE date dateINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL number no.SERIAL NUMBER number no.DUTY Cubic Metres per Minute m3/minHEIGHT metres mMECHANICAL VENTILATION YES/NO - MOTOR SIZE kilowatt kW - MOTOR MANUFACTURER Text chr - MOTOR MODEL number no. - MOTOR SERIAL NUMBER number no.ACCESSIBILITY ACCESSTYPE

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.WALKWAY TYPE WALKWAYTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL number no.SERIAL NUMBER number no.WALKWAY MATERIAL CONSTRUCTEDMATERIALWALKWAY SUPPORT METHOD MOUNTING STYLELOAD LIMITSASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.OWNER/CUSTODIANCERTIFICATION EXPIRY DATE date dateLAST INSPECTED date dateACCESSIBILITY ACCESSTYPE

WALKWAY -- WALK PURPOSE BUILT ABOVE GROUND AND MAINTAINED WALKWAYS THAT ARE MAINTAINED SEPARATED TO AN ASSOCIATED ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

VENT / VENTILATOR -- VENT AN ASSET THAT ALLOWS POTENTIALLY DANGEROUS GASES TO BE VENTED TO THE ATMOSPHERE E.G. FROM A SEWER NETWORK. VENTS INCLUDE VERTICAL RISERS AND NON-MOTORISED VENTILATION EQUIPMENT. MECHANICAL FANS AND ODOUR CONTROL ASSETS WILL BE RECOGNISED AS A SEPARATE ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 81 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 82: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014 LEVEL 5 ASSETS

Domain List NameGRC Asset Type Asset Type Description Asset Type Attributes Attribute Defined Units of Measurement (If Applicable) SI Unit

ASSET ID Conquest Generated number no.ASSET TAG NUMBER a) P&ID Tag for New Assets , previous or existing asset number or

leave blanknumber no.

ASSET TAG NUMBER b) P&ID Sheet no number no.WEIR TYPE WEIRTYPEREFERENCE DRAWINGINSTALLATION DATE date dateDESIGN LIFE year no.CONSTRUCTION COST $ $REPLACEMENT VALUE $ $CRITICALITY number no.CONDITION number no.MAINTENANCE (TYPE / STRATEGY) Type/Strategy Key MAINTENANCEKEYGPS LOCATION GPS and GIS Spatial Position UTM coords no ASSOCIATED ASSET number no.MANUFACTURER Text chrMODEL Text chrSERIAL NUMBER number no.WEIR MATERIAL CONSTRUCTEDMATERIALWEIR SUPPORT METHOD MOUNTINGSTYLEFLOW LIMITS Flow Range Limits m3/HrASSOCIATED ASSET NA/ Asset ID where item firmed affixed to ASSET number no.LAST CALIBRATED/CHECKED date dateACCESSIBILITY ACCESSTYPE

WEIR -- WEIR PURPOSE DESIGNED AND MAINTAINED ASSET FOR REGULATING FLUID FLOW WITHIN BUT MAINTAINED SEPARATE TO AN ASSOCIATED ASSET.

Plan that shows either GA of the asset and/or is specific detail plan

28/05/2014 82 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 83: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATION

FACTORY CONDITION APPLICATION FACTMANUAL HAND APPLICATION HANDSPRAY APPLICATION SPRYCLASS A CL ACLASS B CL BCLASS D CL DNON TRAFFICABLE NOTRAFNOT APPLICABLE NAALUMINIUM GRATE ALMGRTALUMINIUM PLATE ALMPLTASBESTOS CEMENT ACCAST IRON CICONCRETE CONCDUCTILE IRON DI FIBRE REINFORCED PLASTIC FRPFIBRE REINFORCED PLASTIC GRATE FRPGRTFIBREGLASS FGLMILD STEEL GRATE MSGRTMILD STEEL PLATE MSPLTOTHER OTHPLASTIC PLASSTAINLESS STEEL GRATE SSGRTSTAINLESS STEEL PLATE SSPLTTIMBER TIMBUNKNOWN UKNABOVE GROUND PEDESTAL ABVGRDBELOW GROUND CONFINED SPACE ENTRY BGCONFCONFINED SPACE ENTRY-GROUND LEVEL CONFELEVATED CONFINED SPACE ENTRY ELECONFGRC-APPROVAL REQUIRED GRCAPPOTHER OTHPRIVATE LAND PRIVSTANDARD OPERATING PROCEDURE TO FOLLOW SOPAUNRESTRICTED OPENCLOSED GEARBOX (LOCAL) LCLGBOXCLOSED GEARBOX (REMOTE) REMGBOXELECTRIC (LOCAL) LCLELCELECTRIC (REMOTE) REMELCHYDRAULIC (LOCAL) LCLHYDHYDRAULIC(REMOTE) REMHYDLOCAL OR REMOTE LCLMANUAL OPERATION MANOPEN GEARS (LOCAL) LCLGEAROPEN GEARS(REMOTE) REMGEARPNEUMATIC (LOCAL) LCLPNUPNEUMATIC (REMOTE) REMPNUSOLENOID (LOCAL) LCLSOLNSOLENOID (REMOTE) REMSOLN

APPLICATIONMETHOD

ACCESSCOVERTYPE

ACCESSTYPE

ACCESSLIDMATERIAL

ACTUATORTYPE

28/05/2014 83 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 84: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONSUBMERGED- DIFFUSED AIR SUBDIFSURFACE AERATOR WITH HORIZONTAL AXIS SURHORSURFACE AERATOR WITH VERTICAL AXIS SURVETCENTRAL DUCTED DUCTMULTI SPLIT SYSTEM MSPLTOTHER OTHPORTABLE PORTSPLIT SYSTEM SPLTTHROUGH WINDOW / WALL PENTLOG PERIODICPARABOLICYAGIOTHERDRYERFRIDGEMICROWAVEWASHING MACHINEOTHERDATA PROJECTORELECTRONIC WHITEBOARDOVERHEAD PROJECTORWHITE BOARDOTHERAIR DRIVEN AIRDHYDRAULICALLY DRIVEN HYDDMANUAL OPERATION MANPOWER DRIVEN POWDEVENT EVTPERIODIC PERDPROGRAMMABLE PROGFAST FASTINDUCTIVE INDUINTELLIGENT INTLOTHER OTHPULSE PULZSIMPLE SIMPSOLAR SUNTIMER-BASED TIMRTRICKLE TRICUSB-BASED USBFAST FASTINDUCTIVE INDULEAD ACID ACIDLITHIUM ION LITHNICKEL CADMIUM NICDNICKEL IRON NIFEOTHER OTHABOVE GROUND PEDESTAL ABVGRDBURIED ENGINEERED DESIGN BURSPECBURIED TYPE2 BUR2BURIED TYPE1 BUR1PIPE BRIDGE PBRIDMULTI HOPPER- AUTOMATICALLY EMPTIED MHOPAMULTI-BIN, MANUALLY EMPTIED MBINMASINGLE BIN, MANUALLY EMPTIED SBINMASINGLE HOPPER- AUTOMATICALLY EMPTIED SHOPA

SAMPLERTYPE

BINHOPPERTYPE

APPLIANCETYPE

AIRCONDITIONERTYPE

ANTENNATYPE

AUDIOVISUALTYPE

BEDDINGSUPPORTTYPE

AUGERTYPE

BATTERYCHARGERTYPE

AERATORTYPE

BATTERYTYPE

28/05/2014 84 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 85: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONAXIAL AXLCENTRIFUGAL CENTRPOSITIVE DISPLACEMENT POSTDABANDONED\NO Longer in Use ABNDECOMMISSIONED AND REMOVED DECOMINJECTION/DISPOSAL INJMONITORING MONPRODUCTION PRODUNKNOWN UKNADMINISTRATION ADMINCONTROL ROOM CONTRMLABORATORY LABOPERATIONS OPEROTHER OTHPUMP STATION PSTNSTORES STORALUMINIUM ALMCOPPER CUGLASS FIBRE OPTIC OPTICOTHER OTHERAERIAL (SELF SUPPORTING) SELFBARE BAREDIRECT BURIAL BURLSZH (LOW SMOKE ZERO HALOGEN) LSZHOFNP (OPTICAL FIBRE NONCONDUCTIVE PLENUM) OFNPOFNR (OPTICAL FIBRE NONCONDUCTIVE RISER) OFNROTHER OTHPLENUM PLENPVC PVCCOMMUNICATION COMMSINSTRUMENT SIGNAL SIGNPOWER POWROTHER OTHNONE NONELOCKED LOCKSCREW SCRWABS ABSFIBREGLASS FGLMILD STEEL MSNONE NONEPVC PVCSTAINLESS STEEL SSIMPRESSED CURRENT INCURIMPRESSED CURRENT REMOTELY MONITORED INCURMSACRIFICIAL ANODES SACRHYDRAULIC HYDMANUAL MANMECHANICAL MECHOTHER OTHSCRAPPER SCAPRSKIMMER SKIMSWEEP SWEEP

CHAINFLIGHTTYPE

CABLEUSE

CABLECOREMATERIAL

CATHODICTYPE

BLOWERTYPE

CASINGTYPE

BORETYPE

CENTIFUGETYPE

CABLESEATHMATERIAL

CAPTYPE

BUILDFUNCT

28/05/2014 85 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 86: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONAIR BACKFLUSH AIRBCKAUTOMATIC STEP SCREEN STSCRMANUAL RAKE RAKEMANUAL WASH WASHOTHER OTHWATER BACKFLUSH WATBCKNO NONOT APPLICABLE NAUNKNOWN UKNYES YESAXIAL AXLCENTRIFUGAL CENTROTHER OTHRECIPROCATING RECPROTARY LOBE RLOBROTARY SCREW RSCRWROTARY VANE RVANECARD ACTIVATED CARDDNP3 DNPETHERNET ETHNIEC 6087-5 IECMODBUS MODRS 232, RS 485, RS 442 RSTHIRD PARTY 3PTVOICE AND VISUAL VOICVVOICE ONLY VOICCOMMERCIAL SUPPLY COMCCOMMUNITY SUPPLY/RIDER MAIN RIDRMULTI TENNANT MULTIRESIDENTIAL SUPPLY RESSEWERAGE SEWALUMINIUM ALASBESTOS CEMENT ACBRICK BRCKCAST IRON CICONCRETE CONCONCRETE BLOCKS CONBCONCRETE LINED DUCTILE IRON DICLCONCRETE LINED STEEL MSCLDUCTILE IRON DIFIBRE REINFORCED PLASTIC FRPFIBREGLASS FGGALVANISED STEEL GSPLASTIC LINED EARTH EMBANKMENT PLEEMILD STEEL MSPOLYETHYLENE PEPOLYPROPYLENE PPPOLYVINYL CHLORIDE PVCROCK ROCKRUBBER RUBSPIRAL WELDED STEEL SWSSTAINLESS STEEL SSTIMBER TIMBUNKNOWN UNKNOTHER OTH

COMPRESSORTYPE

CLOCKWISECLOSING

CONNECTION TYPE

COMMSTYPE

CLEANINGMETHOD

CONSTRUCTEDMATERIAL

28/05/2014 86 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 87: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONPLASTIC LINED EARTH EMBANKMENTPOST TENSIONED TILT SLABCAST IN SITUPRECASTWELDED STEELBOLTED STEEL PANELSPOST TENSIONED TIMBEROTHERMULTITRODE CONTROLLER MULCONTPROGRAMMABLE LOGIC CONTROLLER (PLC) PLCCONTROL PANEL CONPADISPLAY PANEL DISPAMIMIC PANEL FIELD DEVICE MIMICOTHER PANEL OTHBELT BELTPARENT ASSET SYSTEM PARENTPLATFORM PLATSCREW SCRWHORIZONTAL HORZVERTICAL VERTCLASS A CL ACLASS B CL BCLASS D CL DNON TRAFFICABLE NOTRAFCHAIN OVERHEAD CHOVHDAVIT DAVLIFTING JIB JIBMANUAL, CHAIN-OPERATED, GANTRY MANGANTMANUAL, CHAIN-OPERATED, MONORAIL MANRAILMOTORISED OVERHEAD MOTROVHOTHER OTHASSUMED HEIGHT DATUM ASSAUSTRALIAN HEIGHT DATUM AHDNONE NILOTHER NAMEROAD EDGE V-DRAIN VDRNSUBSOIL DRAINAGE TO STORMWATER SUBSTMSUBSOIL DRAINAGE TO V-DRAINS SUBVMULTISTAGE MULTISINGLE STAGE WITH INTEGRAL RECEIVER VESSEL SINGCONCRETE ENCASED CONCDICL DICLMSCL MSCLSTEEL RAIL SLTINSITU CAST INSITOTHER OTHPRECAST PRE

COUPLEMETHOD

COVERTYPE

EMS TYPE

CONSTRUCTIONTYPE

CONTROLLERTYPE

CONVEYORTYPE

DRYERTYPE

DATUM

DRAINAGETYPE

CRANETYPE

ENVELOPER TYPE

CONTROLPANELFUNCTION

28/05/2014 87 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 88: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONONSITE GENERATED POWER SITEPWROTHER OTHPOWER/BATTERY/UPS BACKUP BATTRETICULATED MAINS POWER RETPOWREXTERNAL EXTINTERNAL INTAXIAL AXLCENTRIFUGAL CENTROTHER OTHOTHER OTHROTARY ROTSCREW SCRWBLOCK BLOCNETTING WITH SECURITY SECOTHER OTHPOST AND WIRE POSTSTEEL RAIL STLRALTIMBER TIMBCENTRAL CONTROL UNIT CENUNTHEAT SENSOR HTSENSMOKE SENSOR SMSENBLANKET BLNKDOUSE SPRINKLER/FLOOD SPRINKFIRE EXTINGUISHER-DRY POWDER DEXTNFIRE EXTINGUISHER-FLUID FEXTNHOSE REEL HREELOTHER OTHCARTRIDGE (CARBON) ACARBMEMBRANE MEMBOTHER OTHREPLACEABLE MEDIA RMEDAKITCHEN KITCHLABORATORY LABOTHER OTHSANITARY SANTBEND BNDBLANK FLANGE ACCESS BLKFLEND CAP ECAPOTHER OTHPIGGING STATION PIGSTREDUCER REDUTEE TEEWYE WYEDIESEL DIESGAS LPGPETROL PETRDISPATCHED WHEN NEEDED DISPATMOBILE MOBLON-SITE FIXDPARENT ASSET SYSTEM PARENTAERATED CHAMBER AERCHAMHORIZONTAL HORZPARENT ASSET SYSTEM PARENTVORTEX VORT

FITTINGTYPE

ENERGYTYPE

GRITCHAMBERTPYE

FIXTURETYPE

EXPOSURE CLASS

FANTYPE

FEEDERTYPE

FILTERTYPE

FUELTYPE

FIREALARMTYPE

GENERATORTYPE

FENCETYPE

FIRETYPE

28/05/2014 88 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 89: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONCEMENT GROUTED FROM SCREENS SCRGRONONE NONEPRESSURE GROUTED PREGROSURFACE CASING GROUTED TO REGULATED REQUIREMENTS SURGROADIABATIC WHEELDYNAMIC SCRAPED SURFACEFLUID HEAT PHASE-CHANGEPLATE FIN PLATESHELL AND TUBEWASTE HEAT RECOVERY UNITSOTHERDUAL FIRE PLUG DUALOFFTAKE OFFSINGLE FIRE PLUG SINGSPRING SPRGUNDERGROUND UNDGAIR CONDITIONING ACCHEATING HEATVENTILATION VENTARCHIMEDEAN SCREW ARCSCRWDOUBLE ENCLOSED DBLENLNOT APPLICABLE NAOPEN OPENOTHER OTH SEMI-OPEN SOPENSINGLE ENCLOSED SINGENLVORTEX VORTBAYONET INSERTION BAYNNIPPLE NIPLBURIED UNDERGROUND UGRNDCOVER AT GROUND LEVEL (+/- 1 m) SHALELEVATED ELEVFIXED TO STRUCTURE FIXFLOOR AT GROUND LEVEL (+/- 1 m) FLOOROTHER OTHPARTIAL IN GROUND PARTPORTABLE MOBLANALYSER ANALANALYSER / INDICATOR ANAINDANALYSER / INDICATOR / TRANSMITTER ANAINDTRANANALYSER / TRANSMITTER ANATRANCONTROLLER CONTRCONTROLLER / LIMITER CONTRLIMELEMENT (SENSOR) SENSINDICATOR INDCINDICATOR / TRANSMITTER INDTRANLIMITER LIMOTHER OTHERSWITCH SWTTRANSMITTER TRAN

HYDRANTTYPE

GROUTINGTYPE

INSTRUMENTTYPE

HVACTYPE

HEATEXCHANGERTYPE

INJECTORTYPE

INSTALLATION

IMPELLERTYPE

28/05/2014 89 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 90: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONAIR AIRALUMINIUM SULPHATE ALSCLEAN WATER WATEFFLUENT EFFFLUORIDE FLUORLIME LIMENONE NONEOTHER OTHPOLYMER POLYPOTASSIUM PERMANGANATE KMRAW SEWAGE SEWRRAW SLUDGE SLDGRAW WATER RWATSODIUM ALUMINATE NAALSODIUM HYPOCHLORITE NACLSTORMWATER STRMUNKNOWN UKNNONE NONEPOTABLE MANUAL PMANRECLAIMED MANUAL RMANPOTABLE AUTOMATED PAUTORECLAIMED AUTOMATED RAUTOOUTSOURCED OUTSCOMMUNICATIONSELECTRICALHYDRAULICINSTRUMENTATIONPNEUMATICOTHERDIGITAL DIGLEVEL X LXMASTER MASTERNONE NONECHLORINE ANALYSERMEASURING SCALEMICROSCOPEPH METERSPECTROPHOTOMETEROTHER>45 DEGREE WITH HANDRAIL G45H>45 DEGREE WITH HANDRAIL AND FALL PROTECTION G45HFINCLINED <45 DEGREE WITH HANDRAIL L45HINCLINED <45 DEGREE WITH HANDRAIL AND FALL PROTECTION L45HFNON-FIXED PORTOTHER OTHFLOWER GARDEN FLWRHEDGE HEDGLAWN LWNOTHER OTHTREES TREEMERGENCY EMEXTERNAL EXTINTERNAL INTOTHER OTHREGULATORY TYPE REG

LABORATORYEQUIPMENTTYPE

JUNCTIONBOXTYPE

LANDSCAPETYPE

INTERNALMEDIA

LADDERTYPE

LIGHTTYPE

IRRIGATIONTYPE

KEYLEVEL

28/05/2014 90 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 91: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONCLAY CLAYHDPE FULLY LINED HDPEHYPALON HYPAPLASTIC PLASPVC PVC GRC CYCLIC/PREVENTATIVE PROGRAM CYCPMEXTERNAL PROVIDER CYCLIC/PREVENTATIVE PROGRAM EXTNOT MAINTAINED NILREPAIR ON FAILURE ROFRUN TO FAIL and RENEW RTFEXTERNAL DROP EXTDINTERNAL DROP INDSTRAIGHT THROUGH THRUOTHER INFRASTRUCTURE ACCESS INFRSTORMWATER STRMWASTEWATER WWATCONDUCTIVE CONDDIAPHRAGM (MECHANICAL) MECHDOPPLER DOPPELECTROMAGNETIC ELMAGGALVANIC CELL GLVCELLHYDRAULIC HYDRAHYDROSTATIC HYDROINFRA RED INFREDLIGHT INTENSITY LGHTINLUMINESCENT LUMOPTICAL OPTPNEUMATIC PNEUPRESSURE GAUGE PRSGARADAR (MICROWAVE) RADARRADIO FREQUENCY (RF) RFROTAMETER ROTASITE GLASS GLASSTHERMAL MASS THMASSULTRASONIC ULSONVIBRATING FORKS VIBFOTHER OTH

MAINTENANCEKEY

MEASUREMENTMETHOD

MANHOLEDROPTYPE

MANHOLETYPE

LINERTYPE

28/05/2014 91 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 92: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONAMMONIA AMMCONDUCTIVITY CONDCURRENT CURRDENSITY DENSDIFFERENTIAL PRESSURE DIFPRESDISSOLVED OXYGEN DOELECTRICITY ELECFLOW FLOWFREE CHLORINE FCHLOFREQUENCY FREQHUMIDITY HUMDHYDROGEN SULPHIDE H2SLEVEL LVLMOISTURE MOISTMONOCHLORAMINE NH2CLMOTION MOTNITRATE NO3NITRITE NO2OXIDATION REDUCTION POTENTIAL ORPPH PHPHOSPHOROUS PHOSPOWER POWERPRESSURE PRESRADIATION RADSILT DENSITY INDEX SDISPECIFIC GRAVITY SGSPEED SPEEDSUSPENDED SOLIDS SSTEMPERATURE TEMPTORQUE TORQTOTAL CHLORINE TCTOTAL ORGANIC CARBON TOCTURBIDITY TURBUV INTENSITY UVINUV IRRADIANCE UVIRRUV WAVELENGTH UVWAVEVACUUM VACVIBRATION VIBVISCOSITY VISVOLTS VOLTVOLUME VOLWEIGHT WGHTOTHER OTHSAND/GRAVEL SANDRESIN RESINNANO MEMBRANE MEMB

MEDIATYPE

MEASUREMENTTYPE

28/05/2014 92 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 93: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONCOMBINATION COMBELECTROMAGNETIC ELECTFLUME FLUMEHELICAL VANE HELVANMULTI JET MJETOTHER OTHSINGLE JET SJETULTRASONIC ULTRVOLUMETRIC VOLBULK BLKFIRE FIREINDUSTRIAL/COMMERCIAL INDLEAK MANAGEMENT LEAKOTHER OTHPROCESS PROSREPLACED/REMOVED REMRESIDENTIAL RESSOURCE SOURSUBMETER SUBMMASTER MASTSUBORDINATE SUBRAGITATOR AGTPADDLE PADLPROPELLER PROPPARENT ASSET SYSTEM PARENTSTATIC STAT1 13 32 24 46 68 8AUTO-TRANSFORMER AUTODIRECT ON LINE DOLINTELLIGENT INTLSOFT STARTER SFTSTVARIABLE SPEED VARAC ACBRUSHED DC SERVO DCSERVBRUSHLESS AC SERVO ACSERVBRUSHLESS DC DC-BSHDC DCLINEAR LINSERVO SERVBOLT-ON BOLTDIN RAIL MOUNTED DINDRAWOUT MOUNT DRAWFIXED MOUNT FIXOTHER OTHPLUG-IN PLUG

METERUSETYPE

MOUNTINGSTYLE

MOTORSTARTMETHOD

MIXERTYPE

SUBMETERTYPE

MOTORPOLES

MOTORPHASE

MOTORTYPE

METERTYPE

28/05/2014 93 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 94: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATION15 1520 2025 2532 3240 4050 5075 7580 80100 100125 125150 150200 200225 225250 250300 300350 350375 375400 400450 450500 500600 600700 700750 750800 800900 9001000 10001050 10501200 12001350 13501500 1500FITTING FITTGIS/GPS POSITION GGPSJUNCTION JUNCVALVE PIT PITVALVE VALACTIVATED CARBON SYSTEM ACARBBIOFILTER BED BIOLFBIOSCRUBBER BIOSRBCHEMICAL SCRUBBER CHMSRBFLUIDISED BED SCRUBBER FLUSRBPACKED TOWER TOWRPLATE OR TRAY TOWER PTOWRSPRAY TOWER SPTOWRVENTURI SCRUBBER VENSRBFLOOR FLRFLOOR WITH VORTEX PLATE FLRVORSIDE SIDESUMP SUMPTOP ENTRY CASCADE TOPCASTOP ENTRY CONDUCTOR TOPCONACTUATED MANUALLY ACTUDIGITAL/SENSOR CONTROL AUTOMANUAL CONTROL VALVE/LEVER MAN

OUTPUTCONTROLTYPE

ODOURCONTROLTYPE

NOMDIAMETER

OUTLET/INLET/OVERFLOWTYPE

NODETYPE

28/05/2014 94 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 95: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONPROPERTYWORKS OPERATIONWORKS CONSTRUCTIONWATER AND SEWERAGESPORT AND RECREATIONSUSTAINABILITY AND WASTE SERVICESENVIRONMENTAL HEALTH AND COMPLIANCEPARKS AND CONSERVATIONAIRPORTOTHERBY-PASSEQUALIZERINLETOUTLETREGULATINGWASHOUTOTHERBUTT JOINT WELDED BUTWELECTROFUSION WELDED EFUSFLANGED FLGRUBBER RING JOINTED (RRJ) RRJSPHERICAL SOCKET JOINTED (SSJ) SSJWELD COLLAR JOINTED COLWELDED SSJ WLDALKATHENE ALKASBESTOS CEMENT (AC) ACBRASS BRSCAST IRON (CI) CICONCRETE (CONC) CONCCONCRETE LINED CAST IRON (CICL) CICLCONCRETE LINED DUCTILE IRON (DICL) DICLCONCRETE LINED MILD STEEL (MSCL) MSCLDRAIN COIL DRNDUCTILE IRON (DI) DI FIBRE REINFORCED CONCRETE (FRC) FRCFIBRE REINFORCED PLASTIC (FRP) FRPFIBREGLASS FGLGALVANISED IRON GAVGLASS REINFORCED PLASTIC (GRP) GRPM-POLYVINYL CHLORIDE (mPVC) MPVCMILD STEEL (MS) MS O-POLYVINYL CHLORIDE (oPVC) OPVCOTHER OTHPOLYETHYLENE HD (HDPE) HDPEPOLYETHYLENE MD (MDPE) MDPEPOLYPROPYLENE PLYPPOLYVINYL CHLORIDE (PVC) PVCSPIRAL WELDED STEEL WSTLSTAINLESS STEEL (SS) SS STEEL STLUNKNOWN UKNU-POLYVINYL CHLORIDE (uPVC) UPVCVITRIFIED CLAY (VC) VC

OWNERTYPE

PENSTOCKTYPE

PIPEJOINTTYPE

PIPEMATERIAL

28/05/2014 95 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 96: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONBULK RECYCLED WATER BLKRECBULK WATER BLK BY-PASS BYPACOMPRESSED AIR CAIRDISTRIBUTION RECYCLED WATER DISRECDISTRIBUTION WATER DISWATEDUCTOR EDUCTHOUSE DRAIN HDRNOVERFLOW OVRPRESSURE MANIFOLD PMANIPROCESS FLOW PROWATSCOUR SCOURSERVICE CONNECTION SCONNTRUNK RECYCLED WATER TRECTRUNK WATER TWATUNDERDRAIN DRAINVACUUM MANIFOLD VMANIAS4087 PN 16 16AS4087 PN20 20AS4087 PN25 25AS4087 PN35 35OTHER (STATE MAP RATING) NUNKNOWN UKNEARTHERN EMBANKMENT , NO LINER EMBKEARTHERN EMBANKMENT WITH CAY LINER EMBKCLGEOFABRIC LINED FABRHDPE FULLY LINED HDPEOTHER OTHMANUAL DOWNLOAD MANOTHER OTHRTU/TELEMETRY LINKED TELEBELT BLTHYDRAULIC HYDPARENT ASSET SYSTEM PARENTVACUUM VACCATHODIC PROTECTION CATHPEPOXY EXPXFUSION BONDED EPOXY FEXPXGALVANISED GALVNONE NONEOTHER OTHPAINTED PNTTAPE WRAP TAPWUNKNOWN UKNCENTRIFUGAL CENTRDIAPHRAGM DIAPDRY MOUNT DRYMTPACKAGE SYSTEM PACKPISTON PISTPOSITIVE DISPLACEMENT/PERISTALTIC PDAPROGRESSIVE CAVITY PROCAVPROPELLER PROPSCREW SCRWSELF PRIMING SPRIMSUBMERSIBLE SUBANALOG AM AMDIGITAL UHF UHFOTHER OTH

PONDTYPE

PIPETYPE

RADIOTYPE

PROTECTIONTYPE

PLCTYPE

PRESSTYPE

PIPEPRESSURECLASS

PUMPTYPE

28/05/2014 96 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 97: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONASPHALT ASPBITUMASTIC CHIPSEAL BITBLOCK PAVERS PAVCONCRETE CONCGRAVEL GVLNONE NONEEYE WASH EYEEYE WASH/SHOWER COMBINATION ESCOMFALL PROTECTION MECHANISM FALLGAS DETECTOR GASGRATING GRTHAND RAIL HRAILHARNESS HARNLIGHTING LIGTSAFETY CHAIN CHNSelf Contained Breathing Apparatus Hooker System HOOKSelf Contained Breathing Apparatus MASK SCBASHOWER SHWDIGITAL DIFFERENCE DIGSPRING SPRBAR BARDRUM DRMINCLINED DISC IDSCMESH MSHSTEP STPWIRE-WOUND, STEEL CAGE WELDED WIRECOMBINED RISING SEWER CRSEWLOW PRESSURE SEWER LPSEWPROCESS FLOW PROWATSCOUR SCOURSERVICE CONNECTION SCONNSEWER GRAVITY GSEWSEWER RISING RSEWTRUNK RECYCLED WATER TRECARCH ARCCIRCULAR CIRIRREGULAR IRRRECTANGULAR RECTSQUARE SQRTRAPEZOIDAL TRAZUNKNOWN UKNVARIABLE VARLOAMY/SAND LOAMCLAYEY SAND CLSANDCLAY CLAYREACTIVE CLAYS REACLAY

SHAPETYPE

SCALETYPE

SCREENS

SOILTYPE

ROADSURFACE

SAFETYEQUIPMENTTYPE

SEWERTYPE

28/05/2014 97 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 98: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONCOMMUNICATIONS DRIVERS COMMOFFICE / PC / BUSINESS LCLPLC PLCSCADA (HMI) SCDAAQUEDUCT AQUABASIN BASNBRIDGE BRIDCABLEWAY CABWAYCHAMBER CHAMCLARIFIER CLARCOLUMNS CLMSCONCRETE STOP CONSTOPDAM DAMDRY WELL DWELFOUNDATION FTDNFLOW CONTROL FSPLTHEADWALL HDWLOTHER OTHEROSION PROTECTION (RIP RAP) ERPRPIERS PIERPIT PITPLATFORM PLATPOLE POLEROOF ROOFSHELL SHELSILO SILOSUBMARINE CROSSING SUBMSURCHARGE SURCTHICKENER THCKTOWER TOWRTROUGH TROUTUNNEL TUNLUNDER BORE DIRECTIONALLY DRILLED UNDBRWEIR WEIRWET WELL WWELCBR 2 CB2CBR 3 CB2CBR5 CB5NONE NONEDESIGNED FILTER PACK FILTGRAVEL/SANDS DEVELOPED INSITU ISITINTRODUCED GRAVEL GRVLNONE NONE

SURROUNDTYPE

SUBGRADETPYE

STRUCTURETYPE

SOFTWARETYPE

28/05/2014 98 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 99: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONALARM ONLY ALMALARM AND CAMERA ALMCAMBACK TO CENTRAL BASE BKBASOTHER OTHBIN BINCONTACT CHAMBER CLCHFUEL TANK BUNDED FTBUNFUEL TANK UNBUNDED FT HOLDING HOLDHOPPER HOPPOTHER OTHPRESSURE CELL PCELSUMP SMPSURGE SURGCITEC CITCLEARSCADA CLRMIRRI MIRRAIR CORE AIRIRON CORE IRONOIL CORE OILOTHER OTHFIXED FIXMANUALLY PROGRESSED AT GROUNDLEVEL MANNMOTORISED AT GROUNDLEVEL MOTRRAIL/CHAIN RAILELECTRONIC UNITMAGNETIC CIRCUIT BREAKERSMAGNETIC-HYDRAULIC CIRCUIT BREAKERSTHERMAL OVERCURRENT CIRCUIT BREAKERTHERMAL MAGNETIC CIRCUIT BREAKEROTHERACTUATOR ACUTBARE SHAFT BSHFTHYDRAULIC PILOT HYDMANUAL MANOTHER OTHSOLENOID SOLN

TANKTYPE

TRANSFORMERTYPE

VALVEACTUATION

TRAVELMECHANISM

SECRUITYSYSTEMTYPE

TELEMETRYTYPE

TRIPUNITTYPE

28/05/2014 99 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 100: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONAIR RELEASE AIRRALTITUDE CONTROL ALTBACKFLOW PREVENTION BKFLOBOUNDARY BOUNBYPASS BYPACHECK CHKCOMBINATION AIR / VACUUM RELEASE COMRFLOW CONTROL FCONTISOLATION ISOPRESSURE REDUCTION PR PRESSURE RELIEF PRVPRESSURE SUSTAINING PSVSCOUR SCOURVACUUM RELEASE VACRALLOY ALLYBRASS BRSCAST IRON CI OTHER OTHSTAINLESS STEEL SSSTEEL STLU- POLYVINYL CHLORIDE UPVCUNKNOWN UKNBALL CHECK BALLBALL-AND-CONE CHECK BALLCONDIAPHRAGM CHECK DIAFDOUBLE BALL CHECK 2BALLDOUBLE CHECK 2CHKDUCKBILL DUCKLIFT CHECK LFTCHKOTHER OTHREGISTERED AIR GAP AIRGAPRPZ (REDUCED PRESSURE ZONE) RPZSTOP CHECK STCHKSWING CHECK (DOUBLE GATE) 2SWGCHKSWING CHECK (SINGLE GATE) SWGCHKTESTABLE DOUBLE CHECK TSTCHKUNKNOWN UKNWAFER CHECK WAFCHK

VALVENONRETURNTYPE

VALVEMATERIAL

VALVEFUNCTION

28/05/2014 100 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385

Page 101: LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 5 LEVEL 4 LEVEL 6 LEVEL 7 ... Links... · Mixing System MIX Pond / Lagoon POND PONDTYPE Network Nodes NNODE Power Supply PSUPP ENERGYTYPE Outlet Piping

GRC Water_Sewerage Base Asset Heirarchy Descriptions, Assets and Domains_28_05_2014DROPDOWN SELECTIONS

DOMAIN LIST NAME DOMAIN VALUESDOMAIN

ABBREVIATIONMODULATING MODUNORMALLY CLOSED CLOSNORMALLY OPEN OPENOPERATOR SET SETACTUATED VALVE ACUTAIR RELEASE AVBACKFLOW PREVENTION BVBALL BALLBUTTERFLY BUTFYCHOKE CHOKDIAPHRAGM DIAGATE GVGLOBE GLOBKNIFE GATE KNIFNEEDLE NEEDNON RETURN NRVOTHER OTHPINCH PINCPISTON PISTPLUG PLUGSELF REGULATED REGSLEEVE SLEVSLUICE SLUCSTOP BOARDS SBRDUNKNOWN UKNODOUR ODOUROH&S FORCED AIR OHSOTHER OTH12 VOLT DC 12DC24 VOLT DC 24DCHV HVLV 240 LV240LV 415 LV415OTHER DC OTHDCELEVATED ELVOTHER OTHSUSPENDED SUSPBROAD CREST BCRSTV-NOTCH VNOTNO NOYES YES

YES/NO

VALVESTATUS

WEIRTYPE

VENTTYPE

WALKWAYTYPE

VOLTAGE

VALVETYPE

28/05/2014 101 of 101

Version: 2, Version Date: 09/10/2019Document Set ID: 4473385