Single Pole (One location) or 3-Way (Multi-location) Scene Capable Incandescent Dimmer Cat. No. VRIØ6-1L, 600W (Lighted) 120VAC, 60Hz INSTALLATION INSTRUCTIONS DI-000-VRI06-02A WARNINGS AND CAUTIONS: To be installed and/or used in accordance with appropriate electrical codes and regulations. If you are unsure about any part of these instructions, consult a qualified electrician. To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer-operated appliance. Use with incandescent or 120V halogen fixtures only. Vizia RF + TM dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia +™ or Vizia RF + TM remotes for multi-location dimming. Use only one (1) Vizia RF +™ dimmer in a multi-location circuit with up to 9 coordinating remotes (without LEDs) or up to 4 matching remotes (with LEDs). The remote(s) will turn the light on at the brightness level selected at the dimmer. WARNINGS AND CAUTIONS: Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™). Total minimum load must exceed 40W. Dimmer may feel warm to the touch during normal operation. Recommended minimum wall box depth is 2-1/2”. Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. INSTALLING YOUR DIMMER NOTE: Use check boxes when Steps are completed. BK RD YL/RD 2 Terminal Screw marked Red (RD) Coordinating Remote 2 4 Dimmer BK RD YL/RD 1 3 5 3 5 Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD) 1 4 Hot (Black) Neutral (White) Load Dimmer Coordinating Remote (no LEDS) YL/RD YL/RD RD WH RD BK BK Black Do not use for incandescent applications. White Line 120VAC, 60Hz Green Ground Green Ground Tools needed to install your Dimmer Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler 3-Way Wiring with Coordinating Remote (no LEDs) Application: Step 4b Single-Pole Wiring Application: Step 4a Hot (Black) Neutral (White) Load Dimmer BK Black White RD Green Ground Line 120VAC, 60Hz YL/RD Use terminal for 3-way or more applications only. For single pole applications, do not remove this label. Terminal Screw marked Red (RD) 2 BK RD YL/RD Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD) Terminal Label: Use Terminal for 3-Way or More Applications Only. For Single Pole Applications, Do Not Remove This Label. 4 1 3 Strip Gage (measure bare wire here or use gage on back of the dimmer) 5/8” (1.6 cm) cut (if necessary) Step 3 Preparing and connecting wires: This dimmer can be wired using side wire terminal screws or through backwire openings. Choose appropriate wire stripping specifications accordingly. IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. Step 2 Identifying your wiring application (most common): NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician. 2 4 3 1 2 4 1 5 3 3-Way 1. Line or Load (See important instruction below) 2. Neutral 3. Ground 4. First Traveler – note color 5. Second Traveler – note color Single-Pole 1. Line (Hot) 2. Neutral 3. Ground 4. Load Step 1 WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! INTRODUCTION Leviton’s Vizia RF + TM components are designed to communicate with each other via Radio Frequency (RF) to provide remote control of your lighting. Using RF technology allows Leviton to provide the greatest signal integrity possible. Each module in Leviton’s Vizia RF + TM component line is a Z-Wave ® enabled device. In a Z-Wave ® network, each device is designed to act as a router. These routers will re-transmit the RF signal from one device to another until the intended device is reached. This ensures that the signal is received by its intended device by routing the signal around obstacles and radio dead spots. The Scene Capable Incandescent Dimmer is compatible with any Z-Wave ® enabled network, regardless of the manufacturer and can also be used with other devices displaying the Z-Wave ® logo. CAUTION: Remember to exercise good common sense when using the Timer features of your remote, especially when scheduling unattended devices. There can be some unexpected consequences if not used with care. For example, an empty coffee pot can be remotely turned on. If that should happen, your coffee pot could be damaged from overheating. If an electric heater is turned on by remote control while clothing is draped over it, a fire could result. DO NOT USE the remote for the control of high power heating appliances such as portable heaters. This device will not control lighting that is used with electronic low-voltage and high frequency power supply transformers, nor high pressure discharge lamps (HID lighting). This includes mercury-vapor, sodium vapor and metal halide lamps. Back Wire (either hole may be used) Back wire openings use #14-12 AWG solid copper wire only. Side Wire Connection Side wire terminals accept #14 AWG solid copper wire only. WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot wall box wire to terminal screw marked “BK”. Load wall box wire to terminal screw marked “RD”. Dimmer terminal screw marked “YL/RD” should have Red insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked “YL/RD”, use electrical tape to cover. Proceed to Step 5. WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked “BK”. First Traveler wall box wire to terminal screw marked “RD” (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “RD”. Remove Red insulating label from terminal screw marked “YL/RD”. Second Traveler wall box wire to terminal screw marked “YL/RD” (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300ft. Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to terminal screw marked “BK”. First Traveler wall box wire (note color as above) to terminal screw marked “RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “RD”. Second Traveler wall box wire (note color as above) to terminal screw marked “YL/RD”. This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD”. Remote terminal screw marked “WH” should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked “WH”, use electrical tape to cover. Proceed to Step 5. Soft fade ON/OFF Scene capable Two way communication RF reliability No Neutral wire required FEATURES ON/OFF LED and Brightness level LED Ease of installation – No new wiring Compatible with other Z-Wave ® enabled devices Changing the color of your Dimmer: Your device may include color options.To change color of the face, proceed as follows: Line up tabs and press in sides one at a time to attach Push in side at tab to release Installing Dimmer by itself or with other devices If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi- device application, proceed as follows: MULTI-DEVICE APPLICATION: In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer. MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE Cat. No. VRIØ6 600W Single 500W Two Devices 400W More than 2 Devices Hot (Black) Neutral (White) Load Dimmer Matching Dimmer Remote (with LEDs) YL/RD YL/RD RD WH BK BK Black White Line 120VAC, 60Hz Green Ground Green Ground 1 BK RD YL/RD 2 Additional Neutral Wire Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD) BK RD YL/RD 4 3 5 Terminal Screw marked Red (RD) Matching Dimmer Remote Dimmer 4 3 1 2 5 Step 4c 3-Way Wiring with Matching Remote (w/LEDs) Application: Make sure that the ends of the wires from the wall box are straight (cut if necessary). Remove insulation from each wire in the wall box as shown. For Single Pole Application, go to Step 4a. For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b. For 3-Way Matching Remote (with LEDs) Application, go to Step 4c. NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. WIRING MATCHING REMOTE (wall box with Line Hot connection): Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to remote terminal screw marked “BK”. Second Traveler wall box wire from dimmer to remote terminal screw marked “YL/RD” (note wire color). This traveler from the remote must go to the terminal screw on the dimmer marked “YL/RD”. Line Neutral wall box to remote terminal screw marked “WH”. WIRING DIMMER (wall box with Load connection): Connect wires per WIRING DIAGRAM as follows: Green or bare copper wire in wall box to Green terminal screw. Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked “RD”. First Traveler Line Hot to dimmer terminal screw marked “BK”. Remove Red insulating label from terminal screw marked “YL/RD”. Second Traveler wall box wire (note color as above) to dimmer terminal screw marked “YL/RD”. This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. Proceed to Step 5.

Upload: alarm-grid

Post on 26-May-2015

233 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Leviton vri06 1 lz product manual and setup guide

Single Pole (One location) or 3-Way (Multi-location) Scene Capable Incandescent Dimmer

Cat. No. VRIØ6-1L, 600W (Lighted) 120VAC, 60Hz

INSTALLATION INSTRUCTIONSDI-000-VRI06-02A

WARNINGS AND CAUTIONS:• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,fluorescentlighting,amotor-oratransformer-operatedappliance.• Usewithincandescentor120Vhalogenfixturesonly.• Vizia RF +TMdimmersarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziaRF+TMremotesformulti-locationdimming.• Useonlyone(1)ViziaRF+™dimmerinamulti-locationcircuitwithupto9coordinatingremotes(withoutLEDs)orupto4matchingremotes(withLEDs).Theremote(s)willturnthe

lightonatthebrightnesslevelselectedatthedimmer.

WARNINGS AND CAUTIONS:• Dimmermaynotoperatewithdiodedlamps(SylvaniaDesigner16™orPhilipsPAR-16™).• Totalminimumloadmustexceed40W.• Dimmermayfeelwarmtothetouchduringnormaloperation.• Recommendedminimumwallboxdepthis2-1/2”.• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingfixture.• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.

INSTALLING YOUR DIMMER

NOTE: UsecheckboxeswhenStepsarecompleted.√

Bk

RDYL/RD

2

TerminalScrew marked

Red (RD)

Coordinating Remote

2

4

Dimmer

Bk

RDYL/RD

1

3

5

3

5

TerminalScrew marked

Black (Bk)

TerminalScrew marked

Yellow/Red(YL/RD)

1

4

hot (Black)

Neutral (White)

Load

DimmerCoordinating Remote (no LEDS)

YL/RD YL/RD RD

Wh

RD

Bk Bk Black

Do not use forincandescentapplications.

White

Line 120vAC, 60hz

GreenGround

GreenGround

Tools needed to install your Dimmer

Slotted/PhillipsScrewdriver ElectricalTapePliers Pencil Cutters Ruler

3-Way Wiring with Coordinating Remote (no LEDs) Application:

Step 4b

Single-Pole Wiring Application:Step 4a

hot (Black)

Neutral (White)

Load

Dimmer Bk

Black

White

RDGreenGround

Line 120vAC, 60hz

YL/RD

Use terminal for 3-way ormore applications only.for single pole applications, do not remove this label.

TerminalScrew marked

Red (RD)

2

Bk

RDYL/RD

TerminalScrew marked

Black (Bk)

TerminalScrew marked

Yellow/Red(YL/RD)

Terminal Label:Use Terminal for 3-Way or More Applications Only.for Single Pole Applications, Do Not Remove This Label.

4

1

3

Strip Gage (measure bare wire here or use gage on back of the dimmer)

5/8”(1.6 cm)

cut (if necessary)

Step 3 Preparing and connecting wires:Thisdimmercanbewiredusingsidewireterminalscrewsorthroughbackwireopenings.Chooseappropriatewirestrippingspecificationsaccordingly.

IMPORTANT: For3-Wayapplications,notethatoneofthescrewterminalsfromtheoldswitchbeingremovedwillusuallybeadifferentcolor(Black)orlabeledCommon.Tagthatwirewithelectricaltapeandidentifyasthecommon(LineorLoad)inboththedimmerwallboxandremotewallbox.

Step 2 Identifying your wiring application (most common): NOTE:Ifthewiringinthewallboxdoesnotresembleanyoftheseconfigurations,consultaqualifiedelectrician.

2

4

3

1 2

4

1

5

3

3-Way1. Line or Load

(See important instruction below)

2. Neutral3. Ground4. FirstTraveler

– note color5. SecondTraveler

– note color

Single-Pole1. Line (Hot) 2. Neutral 3. Ground 4. Load

Step 1 WARNING: TO AvOID fIRE, ShOCk, OR DEATh; TURN Off POWER atcircuitbreakerorfuseandtestthatpowerisoffbeforewiring!

INTRODUCTION

Leviton’sVizia RF +TMcomponentsaredesignedtocommunicatewitheachotherviaRadioFrequency(RF)toprovideremotecontrolofyourlighting.UsingRFtechnologyallowsLevitontoprovidethegreatestsignalintegritypossible.EachmoduleinLeviton’sVizia RF +TMcomponentlineisaZ-Wave®enableddevice.InaZ-Wave® network,eachdeviceisdesignedtoactasarouter.Theserouterswillre-transmittheRFsignalfromonedevicetoanotheruntiltheintendeddeviceisreached.Thisensuresthatthesignalisreceivedbyitsintendeddevicebyroutingthesignalaroundobstaclesandradiodeadspots.TheSceneCapableIncandescentDimmeriscompatiblewithanyZ-Wave®enablednetwork,regardlessofthemanufacturerandcanalsobeusedwithotherdevicesdisplayingtheZ-Wave® logo. CAUTION:RemembertoexercisegoodcommonsensewhenusingtheTimerfeaturesofyourremote,especiallywhenschedulingunattendeddevices.Therecanbesomeunexpectedconsequencesifnotusedwithcare.Forexample,anemptycoffeepotcanberemotelyturnedon.Ifthatshouldhappen,yourcoffeepotcouldbedamagedfromoverheating.Ifanelectricheateristurnedonbyremotecontrolwhileclothingisdrapedoverit,afirecouldresult.DO NOT USEtheremoteforthecontrolofhighpowerheatingappliancessuchasportableheaters.Thisdevicewillnotcontrollightingthatisusedwithelectroniclow-voltageandhighfrequencypowersupplytransformers,norhighpressuredischargelamps(HIDlighting).Thisincludesmercury-vapor,sodiumvaporandmetalhalidelamps.

Back Wire (either hole may be used)Backwireopeningsuse#14-12AWGsolidcopperwireonly.

Side Wire ConnectionSidewireterminalsaccept#14AWGsolidcopperwireonly.

WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHotwallboxwiretoterminalscrewmarked“BK”.• Loadwallboxwiretoterminalscrewmarked“RD”.• Dimmerterminalscrewmarked“YL/RD”shouldhaveRed

insulationlabelaffixed. NOTE: Ifinsulatinglabelisnotaffixedtoterminalscrewmarked

“YL/RD”,useelectricaltapetocover.• ProceedtoStep5.

WIRING DIMMER:Connect wires per WIRING DIAGRAM as follows:NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmercanbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.NOTE: Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremovingoldswitchto

terminalscrewmarked“BK”.• FirstTravelerwallboxwiretoterminalscrewmarked“RD”(note wire color).This

travelerfromthedimmermustgototheterminalscrewontheremotemarked“RD”.• RemoveRedinsulatinglabelfromterminalscrewmarked“YL/RD”.• SecondTravelerwallboxwiretoterminalscrewmarked“YL/RD”(note wire color).

Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked“YL/RD”.

WIRING COORDINATING REMOTE:Connect wires per WIRING DIAGRAM as follows:NOTE: Maximumwirelengthfromdimmertolastremoteis300ft.• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchtoterminalscrew

marked“BK”.• FirstTravelerwallboxwire(note color as above)toterminalscrewmarked“RD”.

Thistravelerfromtheremotemustgototheterminalscrewonthedimmer marked“RD”.

• SecondTravelerwallboxwire(note color as above)toterminalscrewmarked“YL/RD”.Thistravelerfromtheremotemustgototheterminalscrewonthedimmermarked“YL/RD”.

• Remoteterminalscrewmarked“WH”shouldhaveWhiteinsulationlabelaffixed. NOTE: Ifinsulatinglabelisnotaffixedtoterminalscrewmarked“WH”,useelectrical

tapetocover.• ProceedtoStep5.

• SoftfadeON/OFF• Scenecapable• Twowaycommunication• RFreliability• NoNeutralwirerequired

fEATURES

• ON/OFFLEDandBrightnesslevelLED

• Easeofinstallation–Nonewwiring

• CompatiblewithotherZ-Wave® enableddevices

Changing the color of your Dimmer:Yourdevicemayincludecoloroptions.Tochangecoloroftheface,proceedasfollows:

Line up tabs and press in sides one at a time to attach

Push in side at tab to release

Installing Dimmer by itself or with other devices

IfinstallingDimmerinasingledeviceapplication,proceedwiththeINSTALLING YOUR DIMMERsection.IfinstallingDimmerinamulti-deviceapplication,proceedasfollows:

MULTI-DEvICE APPLICATION:Inmulti-dimmerinstallations,thereductionofthedimmer’scapacityisrequired.Refertothechartformaximumloadperdimmer.

MAXIMUM LOAD PER DIMMER fOR MULTI-DEvICE

Cat. No.

VRIØ6 600W

Single

500W

TwoDevices

400W

More than 2 Devices

hot (Black)

Neutral (White)

Load

DimmerMatching Dimmer

Remote (with LEDs)

YL/RD YL/RDRD

Wh Bk Bk

Black

White

Line 120vAC, 60hz

GreenGround

GreenGround

1

Bk

RDYL/RD

2

AdditionalNeutral Wire

TerminalScrew

markedBlack (Bk)

TerminalScrew

markedYellow/Red

(YL/RD)

Bk

RDYL/RD

4

3

5

TerminalScrew marked

Red (RD)

Matching Dimmer Remote Dimmer

4

3

1

2

5

Step 4c 3-Way Wiring with Matching Remote (w/LEDs) Application:

• Makesurethattheendsofthewiresfromthewallboxarestraight (cut if necessary).

• Removeinsulationfromeachwireinthewallboxasshown.• for Single Pole Application, go to Step 4a.• for 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b.• for 3-Way Matching Remote (with LEDs) Application, go to Step 4c.

NOTE: ThedimmermustbeinstalledinawallboxthathasaLoadconnection.ThematchingremotemustbeinstalledinawallboxwithaLineHotconnectionandaNeutralconnection.ANeutralwiretothematchingremoteneedstobeaddedasshown.Ifyouareunsureaboutanypartoftheseinstructions,consultaqualifiedelectrician.NOTE:Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.WIRING MATChING REMOTE (wall box with Line hot connection):Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• LineHot(common)wallboxwireidentified(tagged)whenremoving

oldswitchandFirstTravelertoremoteterminalscrewmarked“BK”.• SecondTravelerwallboxwirefromdimmertoremoteterminal

screwmarked“YL/RD”(note wire color).Thistravelerfromtheremotemustgototheterminalscrewonthedimmer marked“YL/RD”.

• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.WIRING DIMMER (wall box with Load connection):Connect wires per WIRING DIAGRAM as follows:• GreenorbarecopperwireinwallboxtoGreenterminalscrew.• Loadwallboxwireidentified(tagged)whenremovingoldswitchto

dimmerterminalscrewmarked“RD”.• FirstTravelerLineHottodimmerterminalscrewmarked“BK”.• RemoveRedinsulatinglabelfromterminalscrewmarked“YL/RD”.• SecondTravelerwallboxwire(note color as above)todimmer

terminalscrewmarked“YL/RD”.Thistravelerfromthedimmermustgototheterminalscrewontheremotemarked“YL/RD”.

• ProceedtoStep5.

Page 2: Leviton vri06 1 lz product manual and setup guide

D) ThePrimaryProgrammer/ControllerwillassignanodeIDnumber(Name)forthismodule.

NOTE: ThisIDnumber(Name)willbestoredinthecontrollerlibrarytobeusedforfuturereference.

NOTE: Youmayeditthenameofthisdeviceatthistime.

E) The dimmer is now installed in the network.

NOTE: IfadimmerhasbeensuccessfullyIncludedinthenetworkandtheusertriestoIncludeitagainwithoutfirstexcludingitfromthenetwork,themodulewillretainthefirstnodeIDithadreceivedandignorethesecond.

Testing your Dimmer prior to mounting in wall box:

LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLevitonwarrantstotheoriginalconsumerpurchaserandnotforthebenefitofanyoneelsethatthisproductatthetimeofitssalebyLevitonisfreeofdefectsinmaterialsandworkmanshipundernormalandproperuseforfiveyearsfromthepurchasedate.Leviton’sonlyobligationistocorrectsuchdefectsbyrepairorreplacement,atitsoption,ifwithinsuchfiveyearperiodtheproductisreturnedprepaid,withproofofpurchasedate,andadescriptionoftheproblemtoLeviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591.Thiswarrantyexcludesandthereisdisclaimedliabilityforlaborforremovalofthisproductorreinstallation.Thiswarrantyisvoidifthisproductisinstalledimproperlyorinanimproperenvironment,overloaded,misused,opened,abused,oralteredinanymanner,orisnotusedundernormaloperatingconditionsornotinaccordancewithanylabelsorinstructions.There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandfitnessforaparticularpurpose,islimitedtofiveyears.Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation.Theremediesprovidedhereinaretheexclusiveremediesunderthiswarranty,whetherbasedoncontract,tortorotherwise.

• Restorepoweratcircuitbreakerorfuse.• PresspaduntillocatorlightisOFF.Lights

shouldturnON.IflightsdonotturnON,presstherighthalfofDIM/BRIGHTbaruntilthelightsbrighten.

If lights still do not turn ON, refer to the TROUBLEShOOTING section.

DI-000-VRI06-02A

ProtectedunderU.S.PatentNumber6,388,399andpatentspending andlicensedunderU.S.PatentsNumbers5,905,442,and5,982,103

• Lights flickering - Lamphasabadconnection. - Wiresnotsecuredfirmlyunderterminalscrewsofdimmer

and/orremote. - Localswitch,ON• Light does not turn ON and Locator LED does not turn ON - Circuitbreakerorfusehastripped. - Lampisburnedout. - LampNeutralconnectionisnotwired. - Confirmthatthedeviceisbeingsuppliedfroma120V,60HzAC

sourceONLY. - Confirmthatunitisprogrammedproperly.Repeat“TOINSTALL”

sectiontoverifythatithasbeenincludedintheZ-Wave™network.

• Intermittent dimmer operation - Minimumloadisunder40W. - ConfirmthattheLoadbeingcontrolleddoesnotexceedthe

600Wdimmerlimit.• Remote does not operate lights - Ensurethattotalwirelengthdoesnotexceed300ft.

TROUBLEShOOTING

for additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at

www.viziaRf+.com

NOTE:ThelocatorlightwillilluminatewhentheloadisintheOFFpositiontofacilitateaccessinthedark.NOTE:Ifusingthedimmerina3-wayapplication,thelightswillturnONatbrightnesssetondimmer’sDIM/BRIGHTbar.Thelightingcanbecontrolledfromeitherthedimmerortheremotelocation.Push Pad (Default settings) Turn ON from Off position: Tap–LightsturnONtopresetlevel. PressandHold–LightsturnONtofullbright.Turn Off from ON position:Tap–LightsturnOFF.

LED Brightness Display

DIM/BRIGhT Bar

Push Pad

Locator Light

OPERATION

Installationmaynowbecompletedbytighteningmountingscrewsintowallbox.Attachwallplate.

Dimmer Mounting: TURN Off POWER AT CIRCUIT BREAkER OR fUSE.

Restore Power: Restorepoweratcircuitbreakeror fuse.Installation is complete.

Step 7

Step 6

NOTE: ItisveryimportanttoaccuratelyExcludedevicesfromthenetworkwhenmovingorremovingadevicefromaZ-Wave®network.ThisensuresthatallinformationhasbeenremovedfromyourPrimaryProgrammer/Controller’sinformationtableandisnotcountedontobeapartofthemeshnetwork.A)IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,

presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.

B) Whilestandingclosetothedimmer,pressthecenterbuttonto<Exclude>devicefromthenetwork.WhiletheProgrammer/ControllerisintheExclusionmodeandthelocatorLEDisONonthedimmer,pressthepushpadonthedimmer.TheProgrammer/ControllerwillverifyExclusionandthelocatorLEDwillturnOFFonthedimmer.

IfthedimmerisflashingAmberwhileintheExlusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsflashing,thenpressthepushpad.

factory Default:Ifyourdimmerisnotresponding,oryouareunabletocontrolitafteryouhavetriedtoInclude/Excludeitmultipletimes,itmaybenecessarytoresetthedimmertoitsoriginalfactorysettings.Toaccomplishthis,proceedasfollows:• Onthedimmer,engagetheair-gapswitch(refer to Operation

section)andwait5seconds.PresspushpadbackintoframeandholdpushpaduntilthelocatorLEDturnsAmberandthenflashesRed.Thedimmerisnowreset.Oncethedimmerisreset,itwillbenecessarytoRe-Includeittoanetworkbeforeitcanbeused.

CAUTION:SETTINGADEVICETOAFACTORYDEFAULTDOESNOTEXCLUDETHATDEVICEFROMANETWORK.THEEXCLUSIONPROCEDUREMUSTSTILLBEFOLLOWEDTOREMOVETHEDEVICEFROMTHEPRIMARYCONTROLLER’SINFORMATIONTABLE.FAILURETODOSOMAYRESULTINASYSTEMTHATISSLOWTORESPOND,ORMAYFAILTORESPONDTOSOMEDEVICES.

Step 9 Excluding Dimmer from Network:

NOTES:• Ifusinganon-LevitonProgrammer/Controller,

refertotheProgrammer/ControllerinstructionsheetforIncludingadevice.

• IfusingtheVRCPG'sInstallChecklistfeature,godirectlytoStepB.

A)IfusingaLevitonZ-Wave®Programmer/Controller,Cat.No.VRCPG,presstheMenubuttonandscrolldowntoSystemSetup.PressthecenterbuttontoselectSystemSetupMenu.ChooseAdvancedSettings.PressthecenterbuttontoselectNetwork.

B)Whilestandingclosetothemodule(approx.2-5ft),pressthecenterbuttonto<Include>deviceinthenetwork.

NOTE:Onlyonedevicemaybeincludedatatime.DO NOTputmultipledevicesintotheInclusionmodeatanytime.

C) WhiletheProgrammer/ControllerisintheInclusionmodeandtheLocatorLEDisONonthedimmer,pushthepushpadtoturnONthedimmer.TheProgrammer/ControllerwillverifyinclusionandthelocatorLEDwillturnOFFonthedimmer.

IfthedimmerisflashingAmberwhileintheInclusionmode,theProgrammer/Controllerisstilltryingtocommunicatewiththedimmer.Waituntilthedevicestopsflashing,thenpresspushpad.

NOTE:IfthelocatorLEDonthedimmerturnssolidRedwhileincluding,therehasbeenacommunicationerror.RefertoTroubleshootingsection.

Programmer/Controller Cat. No. vRCPG

Menu Button

1 ON

2 ON

3 ON

4 ON

OFF

OFF

OFF

OFF

Center Button

Including Scene Capable Dimmer into Z-Wave® Network:

Step 8

NOTE: Dresswireswithabendasshownindiagraminordertorelievestresswhenmountingdevice.

• Positionallwirestoprovideroominoutletwallboxfordevice.

• Ensurethattheword“TOP”isfacingupondevicestrap.

• Partiallyscrewinmountingscrewsinwallboxmountingholes.

Step 5

A-2) TheLocatorLEDwillblink2timespersecondtoindicatethedeviceisinProgramModeA-2, Minimum Brightness Level. TochangetheMinimum Brightness Levelfrom1-50%,usetheDIM/BRIGHTBar.Thelightoutputwillreflecttheminimumbrightnesslevelselected.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,A-3.

A-3) TheLocatorLEDwillblink3timespersecondtoindicateProgramMode A-3, Preset ON Level.TochangethecurrentPreset ON Levelfrom1-100%,usetheDIM/BRIGHTBar.Ifthisfeatureisnotdesired,pressandholdthelefthalfoftheDIM/BRIGHTBar(v) untilnoLEDislit(defaultsetting).BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeA.

Program Mode BTo enter Program Mode B:PressandholdthePushPadandthenthelefthalfofthe DIM/BRIGHTBar(v)for5secondsuntiltheLocatorLEDandrightmostLED(LED7)begintoblink.B-1) UponreleasingthePushPadandthelefthalfofthe

DIM/BRIGHTBar(v),theLocatorLEDwillcontinuetoblinkoncepersecondindicatinghedimmerisinProgramModeB-1, ON fade Rate.TochangetheON fade Rate,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccordingtoChart B.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,B-2.

B-2) TheLocatorLEDwillblink2timespersecondtoindicateProgramMode B-2, Off fade Rate.TochangetheOff fade Rate,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetlevelaccording to Chart B.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,B-3.

LED BrightnessDisplay

1 2 3 4 5 6 7

Definition of A ModesA-1) EnergySave:Setsthemaximumbrightnesslevelforenergy

savings.A-2) MinimumBrightnessLevel:Setstheminimumdimminglevel.A-3) PresetONLevel:Setstheturnonbrightnesslevelregardlessof

theprevioussetlightlevel(formerlyDimLock).Definition of B ModesB-1) ONFadeRate:Setstheamountoftimeinsecondsittakesthe

lightstoturnONtomaximumbrightness.B-2) OFFFadeRate:Setstheamountoftimeinsecondsittakesthe

lightstoturnOFFfrommaximumbrightness.B-3) LEDOptions:SetsthetimeperiodinsecondstheLocatorLED

andBrightnessdisplaywillstayonbeforeextinguishing.

Definition of LEDsLeftmostLED=LED1RightmostLED=LED7NOTES:• Thedevicewillexitprogramming

modeafter3minutesofinactivity.• Pressingthepushpadatanytime

duringprogrammingwilladvancethedevicetothenextprogrammingmode.

ADvANCED PROGRAMMING fEATURES

Program Mode ATo enter Program Mode A:PressandholdthePushPadandthentherighthalfofthe DIM/BRIGHTBar(^)for5secondsuntiltheLocatorLEDandleftmostLED(LED1)begintoblink.A-1) UponreleasingthePushPadandtherighthalfofthe

DIM/BRIGHTBar(^),theLocatorLEDwillcontinuetoblinkoncepersecondandtherightmostLEDwillilluminatetodisplaythedeviceisinProgramModeA-1, Energy Save.Thedefaultenergysavemodeis100%i.e.fullbright.Tochangethe Energy Savelevel,usetheDIM/BRIGHTBartomovethecorrespondingLEDtothedesireddiscretepresetlevelaccording to Chart A.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewilladvancetothenextprogrammingmode,A-2.

B-3) TheLocatorLEDwillblink3timespersecondtoindicateProgramMode B-3, LED Options.TochangetheLED Optionssettings,usetheDIM/BRIGHTBartomovetheLEDtothedesiredpresetsettingaccordingtotheChart B-3.BytappingthePushPadthissettingwillautomaticallybesavedandthedevicewillexitProgrammingModeB.

LED

LED 1

LED 2 (Default)

LED 3

LED 4

LED 5

LED 6

LED 7

FADE ON

0 seconds (instant)

0.5 seconds

1.5 seconds

3.0 seconds

6.0 seconds

10 seconds

25 seconds

0 seconds (instant)

0.5 seconds

1.5 seconds

3.0 seconds

6.0 seconds

10 seconds

25 seconds

FADE OFF

Chart B

When indicatorlight is at LED #

7654321

Light output is at

100%97%95%90%85%80%75%

Energy consumptionsavings amounts to

0%5%8%

11%14%17%20%

Chart A Chart B-3

LED

LED 1

LED 2

LED 3

LED 4

LED 5

LED 6

LED 7

LOCATOR LED TIMEOUT

Active

Active

Active

Active

Turns off 5 sec. after use

Turns off 5 sec. after use

Turns off 5 sec. after use

LED BRIGHTNESS DISPLAY OPTIONS

Active

Turns off 5 sec. after use

Active

Turns off 5 sec. after use

LED Bar active

LED Bar turns off 5 sec. after use

LED Bar turns off 5 sec. after use

vRCPG Programmer/

Controller

NOTE: Remotemustbeincloseproximitytodimmerwhenincludinginnetwork.

DIM/BRIGhT Bar BRIGhTEN:PressrighthalfofDIM/BRIGHTBar–Lightsbrightentodesiredlevel.DIM:PresslefthalfofDIM/BRIGHTBar–Lightsdimtodesiredlevel. IfyoucontinuetoholdthelowerhalfoftheDIM/BRIGHTBar,thelightswillDIMtominimumlevelandthenturnOFF. NOTE:WhenlightsareOFFyoucanchangethelightlevelthatthelightswillturnONtousingtheDIM/BRIGHTBar.Ifthereisapoweroutage,whenthepowerisrestoredthelightswillreturntothelastsettingbeforethepowerinterruption.Air-Gap Switch:Onthedimmeronly,engage theair-gapswitchbygentlypressingthetopofthepushpaduntilthebottomliftscompletelyoutoftheframeandaclickisheard (refer to figure).LEDswillturnOFF. Thiswillcutpowertothefixturetoreplacethebulb.Afterservicingiscomplete,pushthepushpadbackfornormaloperation.Cleaning: Cleanwithadampcloth.DO NOT usechemicalcleaners.

Gently press top of push pad

ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBDigitalDevice,pursuanttoPart15oftheFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentOFFandON,theuserisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowingmeasures:• ReorientorrelocatethereceivingAntenna.• Increasetheseparationbetweentheequipmentandthe

receiver.• Connecttheequipmentintoanoutletonacircuitdifferentfrom

thattowhichthereceiverisconnected.• Consultthedealeroranexperiencedradio/tvtechnicianfor

help.

fCC COMPLIANCE STATEMENT

2008©LevitonMfg.Co.,Inc.