lf series premium - asybco.com · lf series premium asybco low pressure 300 series lf series...

16
ASYBCO LF SERIES PREMIUM LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES

Upload: vanmien

Post on 17-Apr-2019

225 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

ASYB

CO

LF SERIES PREMIUM

LOW PRESSURE

300 SERIES

LF SERIES QUALITY

PRESSURE GAUGES

Page 2: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

DUPLEX

DIFFERENTIAL

3A SANITARY GAUGES

Available in following versions

A - Panel mountB - Bottom connectionC - Back connections

ASYB

CODIFFERENTIAL PRESSURE

SANITARY GAUGE

Page 3: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

ASYB

CO

INDUSTRIAL DIAL BIMETALS THERMOMETERS

THERMOWELLS

300250

oF

200

150

10050

350

400

450

500

STRAIGHT - BACK CONNECTION3’’ - 5’’ Dial

ADJUSTABLE ANGLE3’’ - 5’’ Dial Bimetals

STRAIGHT - BOTTOM CONNECTION3’’ - 5’’ Dial

POCKET THERMOMETER WITH CASE

Page 4: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ER

ROTARY AUTOMATIC LEVEL INDICATOR

Model GR - General Purpose

Popular low cost unit featuring compactsize and simple design for greater depend-ability. Ideal for use with pratically anymaterial. Quickly mounted in any positionwhere level detection is desired. Fits into1/2 of standard 1 1/4” coupling welded tobin wall. Special flexible mounting plates also available. Castaluminum housing, choise of stainless steelpaddles. 115V A.C. motor, two SPDTswitches. U/L Listed.

Model GRX - Explosion proof

Has all the features and advantages of themodel GR, but also meets critical machin-ing and tolerance specifications. Listed byU/L for use in hazardous locations. Class II,Groups E, F and G.

Optional motors with different voltages andfrequencies available upon request.

High & Low Level Indicator

Iterchangeable with other bin level controlunits

Most Compact

Unit on the market, U/L approved... for usein hazardous locations.

Built-In Slip Clutch

Manually turns motor in either direction without damaging equipment.

FULL COUPLINGFor use with Bin-Master Rotary Models GRand GRX. This model is used for top of bininstallations where shaft extensions andshaft guards are required.

HALF COUPLINGFor use with Bin-Master Rotary Models GRand GRX. This model is used primarily forthe side of bin installations.

SPECIFICATIONS

TOP MOUNT SIDE MOUNT

Drilled andTappped for 3/4”Rigid Comduit One half of 1-1/4” Pipe

Coupling Weided to Pin

BinWall

BinWall

Short solid withunits should be usedon side mount

With Flexible Shaft With Short Solid Shaft

Insertable Paddle1-1/4” Pipe CoulpingWelded ton Bin

4” Pipe Extension Tretedinto flexible coupling

1 - 1/4” Support Pipe

1/4” Pipe Coupling

Bin Wall

To requiredMaterial level

Page 5: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ERLEVEL INDICATORS

• High/Low level indicator for liquids and granular solids

• 64 capacitance settings for maximum sensitivity• Automatic compensation for material

buildup on probe• Digital switches make installation quick

and simple

Point level indicator for high-, intermediate-,or low-level detection of liquids or free flowing granular solids. The Probe is suitable for side ortop installation in hoppers, silos, tanks or other containment vessels. The single assembly solidstate electronics are protected within a weatherproof, corrosive resistant, glass-filled nylonenclosure. An optional remote probe is availablefor use in high vibration or high temperature locations or where mounting limitations exist.

MULTI-SET GP1000RF Capacitance Probe

PRO II X 3ADairy Grade Capacitance Probe

SPECIFICATIONSPowerRequirements: 120/240 VAC, 50/60 Hz +

15%, 5VA.Output Relay: DPDT 10 Amp at 250 VAC.

TemperatureElectronics: -40 to 185oF (-40 to 85oC).Probe: up to 250oF (121oC).Pressure: 200 PSI.

SensitivitySetting: Adjustable sensitivity

to < 1 Picofarad.

Calibration: “Quick Set” coarse/fine”single turn potentiometers.

Fail-Safe: Switch selectable, High/Low.

Time Delay: Adjustable .25 to 10 seconds.

Enclosure: Cast aluminum, bolt-on cover,USDA approved finish.

Mounting: 1” sanitary ferrule with optional.Tri-clover “Quick Release” clamp.

ApprovalRatings: CSA, NRTL/C

NEMA 4X, 5, 9 & 12Explosion proof for class II, div. 1 & 2, groups E, F & G3A dairy food grade.

• Design for dairy and food applications.• Holds calibration across entire

temperature span.• Operates below RF range, eliminating

RF interference.• PRO Shield protection ignores

material build-up.• Fail-safe protection.• Static discharge protection - a big plus for

pneumatically conveyed products!

The probe assembly is made of 5/8” 316 SS, and covered by a Delrin plastic sleeve, making it extremely durable, abrasion resistant, and suitablefor use in almost any material.

One Size Fits All

• Suitable for use in solids, liquids, and slurries.• Corrosion resistant.• Suitable for use in conductive and/or

abrasive material.

Page 6: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ER

PRO AUTO-CALCapacitance Sensor for Point Level Detection of Solids, Liquids and Slurries

SPECIFICATIONSPower

Requirements: 120/230 VAC + 10%, -15%56/60 Hz, 5VA

Output Relay: DPDT 10 Amp at 250 VAC

Temperature

Ambient: -40oF to +160oFElectronics: -40oC to +70oC)Probe: up to 250oF Delrin / up to 500oF

Teflon

Pressure: 500 PSI, 3/4” mountSensitivity: Adjustable sensitivity

to < 1 PicofaradFail-Safe: Switch selectable, High/LowTime Delay: Adjustable .3 to 10 secondsEnclosure: Cast aluminum, bolt-on cover,

FDA approved finishConduit Entry: 3/4” NPTMounting: 1 1/4” NPT, 3/4” NPT, or

1” sanitary fitting 316 SSPro-Shield: Compensates for material build-up

Approval

Ratings: NRTL/CPending: NEMA 4X, 5, 9 & 12

class II, div. 1 & 2, groups E, F & GStatus indicator: Visual LED Indicates

sensor status:covered, uncovered,power failure,and calibration

Status Probe: Standard food grade, flush

mount.Options: Flexible extension, high temp,stubby,

and extended shield

Auto-calibrate

Calibration initiated through the cover with mag-netic applicator, or internal push button; 5 switchselectable sensitivity settings.

External Test Feature

Simulates covered or uncovered conditionsthrough the cover using magnetic applicator

Additional features

• Pro-Shield technology eliminates false readingscaused by material buildup.

• Unique circuitry design eliminates seasonal recalibration

• Operates below the radio frequency range to eliminate RF interference

• Four levels of static electric discharge protectionguard against false alarms and unit damagethat commonly occur with pneumatic conveying.

LEVEL INDICATORS

VR SERIES VIBRATING SENSORS

SPECIFICATIONSPower

Requirements: 115/230 VAC, 50/60 Hz,

24VDC

Consumption: 2 VA

Output: SPDT relay, 5a @ 250 VAC

Fail-Safe: High/low switch selectable

Temperature

Electronics: -40 to 150oF (-40 to 65oC)Process: -40 to 190oF (-40 to 88oC)

Pressure: 500 psi

Sensitivity: High / Low switch selectable

Time Delay: 1 sec. from stop of vibration2-5 sec. from start of vibration

Enclosure: Die cast aluminum

Probe: 304 SS, 7.37” - 19.5’insertion length

Conduit Entry: PG 13.5 or 1/2” NPT

Mounting: 1 1/2” NPT

Status Indicator: Relay: Red LED on PCBPower: Yellow LED on PCB

Min. MaterialDensity: 2 lb./cu. Ft. (32 kg / m3)

Principle of Operation

The VR Series are piezoelectric deviceswith a single blade shaped vibrating element.When material comes into contact with theprobe,the vibration is dampened. This change isdetected by the unit’s electronics, activating a relay signal. Conversely, when the materi-al falls away, the probe resumes normalvibration, and the relay switches back.

Sensitivity and buildup

Are tip sensitive, allowing them to overlooksidewall buildup. Not recommended for use in sticky or stringy materials. VR series fea-ture a low sensitivity setting for productsthat leave a light residue on the probe.

• Suitable for high and low level indication,or plugged chute detection

• Detects extremely light, fluffy materials and materials with low dielectric constants

• Unique “Blade” probe design reducesfalse

alarms caused by buildup• Insertion length of 7.37”. The VR 41

is extendable up to 13’, through the use of a solid extension tube. The VR 51 is extendable up to 19.5’ through the use of a flexible cable extension.

Page 7: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ERSmartbob INVENTORY MEASUREMENT SYSTEM

WORKS IN ANY ENVIRONMENT

The remote sensor quickly lowers a weightedBob at 2 ft/sec from the top of the storage

vessel to the surface of the material inside. Asthe Bob desends, a microprocessor in theremote measures the amount of the cable

releaced. When the Bob makes contact withthe material surface, the information is

digitally transmitted, and the Bob instantlyretracts to a neutral position at the top of the

vessel. The retract distance is also measuredfor diagnostic purposes to assure that an

accurate mesurement was taken. The systemcompletely ignores dust, echo, vapors,

temperature fluctuations, steam, or materialdesities. This system is capable of measuring all

your liquid, slurry, or powder and dry bulksolid applications.

CHOICE OF REMOTE SENSORS

SENSOR PROBE OPTIONS

SBRGeneral purpose remote sensorwith diecast aluminum housing

and NEMA 4, 5, and 12 enclosure.

BBP-1Spike designed for granular

materials with angle of repose.

BBP-2Hollow stainless steel inverted

cone designed for liquids and light materials.

SBRXExplosion-proof remote sensor

with powder coated white hous-ing and Class I, Groups C & D and Class II, Groups E, F & G

hazardous location approvals

BBP-3Bottle Bob filled with material

compatible with the materialstored in the vessel. Designed

for material with a bulk densityof 20 lbs. per cu/ft or greater.

BBP-4Submersible torpedo probedesogned to measure solids

submersed in liquids.

Page 8: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ER

CONSOLE CONTROLLED SYSTEM

PC CONTROLLED SYSTEM

PLC/DCS SYSTEM

ROTARY AUTOMATIC LEVEL INDICATOR Smartbob

System runs manually from a SBC console which can control fromone (1) to thirty (30) SBR/SBRX Remote Sensors. A measurementis initiated with a push of a button, giving accurate inventory read-ings in feet of product, feet to product, and percent full. The lastmeasurement on each remote is stored in non-volatile memory.

System Equipment Requirements

• One SBR/SBRX per vessel• One SBC console per system• One transformer per system

(Additional may be required when using heaters)

System is designed to work in conjunction with an IBM compatiblepersonal computer using BinMaster’s Inventory Management

System (IMS) software. This system can control up to 30SBR/SBRX Remote Sensors per com port. The software provides agraphical representation of the measurement in distance, weight,and percent full.The IMS software also provides current inventory, extended inven-tory, date/time, and measurement scheduling capabilities.

System Equipment Requirements

• One SBR/SBRX per vessel • One IMS Software program with RS-232 to RS-485

interface per system• One transformer per system

(Additional may be required when using heaters)

System for a simple interface between the SBR/SBRX RemoteSensor and PLC or DCS system. The PLC/DCS can initiate ameasurement by providing a dry contact closure to the BinMasterRemote Start Unit (RSU). The PLC/DCS can then retrieve themeasurement from analog 4-20 mA current loop output from theRSU. The RSU will also provide a remote display.

System Equipment Requirements

• One SBR/SBRX per vessel• One RSU remote start unit per vessel• One transformer per system

(Additional may be required when using heaters)

Page 9: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ERDIAPHRAGM POINT LEVEL CONTROLS

GENERAL PURPOSE, MOUNTED INTERNALLY• For nonhazardous applications

BM45-R Standard Neoprene diaphragm

BM45-RH Heavy duty neoprene diaphragm

BM45-RHT Heavy duty silicone diaphragm

Specifications: BM 45 Series

Housing : Rugged die-cast aluminumDiaphragm : Neoprene (standard or heavy), siliconeSwitch : Snap-action, 15 amp, 125, 250, or 480 VACMounting plate : 16 ga. galvanized steelDimensions : 6 5/8” wide, 7” high, 2 5/8” deepShipping weight : 2 1/2 lbs.

GENERAL PURPOSE, MOUNTED EXTERNALLY• This variation of the BM45 series permits mounting of the entire unit

outside the bin, making the operating mechanism readily accessible.

BM45-F Standard neoprene diaphragm

BM45-FH Heavy duty neoprene diaphragm

BM45-FHT Heavy duty silicone diaphragm

Note: For all BM45 and BM65 Series

On the heavy duty versions the diaphragm is thicker and the snap-action switch is less sensitive. These units are designed for heavier mate-rials.

The silicone diaphragm versions are designed to remain more resilientand sensitive in extreme temperature conditions.

EXPLOSION-PROOF, MOUNTED INTERNALLYThe BM65 series has the same operating benefits as the BM45 series butis designed for use in hazardous atmospheres charged with grain dust,carbon black, and metal dust. The BM65 series is listed by U/L for Class II, Groups E, F and G.

BM65-R Standard neoprene diaphragmBM65-RHT Heavy duty silicone diaphragm

Specifications: BM65 Series

Housing : Heavy cast aluminumDiaphragm : Neoprene (standard), siliconeSwitch : Snap-action, 15 amp, 125, 250, or 480 VAC

EXPLOSION-PROOF, MOUNTED EXTERNALLYThis variation of the BM65 series permits mounting of the entire unitoutside the bin, making the operating mechanism readily accessible.

BM65-F Standard neoprene diaphragmBM65-FHT Heavy duty silicone diaphragm

Specifications

Dimensions : 6 1/2” wide, 6 5/8” high, 2 5/8” deepShipping weight : 3 lbs.Additional specifications : BM65-F, BM65-FHTMounting plate : 16 ga. galvanized steel

• For use with dry, free flowing materials

• Simple rugged construction

• Low initial cost

• High or low level applications

• Materials pressing against the flexible diaphragm actuates the sensitivemicro switch, which immediately sets off a light and/or a horn,starts or stops a motor.

• Can be wired to deliver response whenever you want it automatically

Page 10: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ER

PROBE

PRO POINTFor reliable level measurement and plug chute detection in liquid, powder, granular,and pelletized materials

SPECIFICATIONS

Power

Requirements : 120 VAC 1.5 VA

Output : SPDT relay, 5a @ 250 VAC

Temperature

Electronics : -40 to 185oF (-40 to 85oC)Probe : -40 to 240oF (-40 to 116oC)

Enclosure : NEMA 4X, Dust tight,water resistant sensitivity

Setting : Adjustable sensitivity to < 1 Picofarad

Calibration : Multi-turn potentiometer

Fail-Safe : Switch selectable,High/Low

Time Delay : Adjustable 1 to 30 seconds

Enclosure : PVC

Probe : CPVC

Mounting : 1” NPS (1 1/4” NPS adapter available)

LED : Indicates material presence or absence

Features

• Works where proximity switches don’t• For tanks, bins, silos, chutes, conveyors,

pipes, and load out hoppers• ProShield feature ignores material buildup• LED on housing indicates sensor status• Easy “one-time” calibration• For metal, plastic or other

non-metallic vessels• ProPoint offers the same features found

in more expensive capacitance probe sensors.

• Visual LED on housing indicates sensor status

• Operation is not effected by changes in temperatures - eliminates the need for bothersome re-calibration

• Four levels of static discharge protection - important for pneumatically conveyed materials

• 5 Amp, SPDT fail-safe relay output (switch selectable high/low fail safe)

High Level

Plug Detection

Low Level

Page 11: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

GARN

ER

PROBE

FLOW / NO FLOW DETECTION FOR SOLIDS AND POWERS

Features

• Reliable doppler technology.• Indicates flow/no flow conditions of solids and

powders in pipelines,chutes, and feeders.

• Non-intrusive flush mounting senses through non-metallic surfaces.

• Non-contact operation eliminates flow stream interruption and equipment wear.

• Control settings can be made without accessing the remote sensor probe.

• Fail-safe power protection and loop fault monitor.• “Quick Set” selectable, single turn calibration.• Explosion-proof design.

Process of operation

The flow detect 1000 is capable of sensing through non-metallic surfaces. A low energy signal is transmitted through a teflon processseal into the material flow stream. Some of this signal is reflectedback to the sensor with a frequency shift resulting from the motionis called the doppler shift and is used by the sensor to determinematerial flow. This state of the art Doppler method of flow detection is far more accurate and dependable than mechanical,triboelectric, or ultrasonic methods. It is virtually unaffected byhumidity, ambient light, pressure, vacuum, temperature, noise,electrical signals, non-metallic build-up, or dust.

REMOTE SENSOR PROBE

Enclosure : Aluminum, urethane powder coat,NEMA 4X

Operating To : -22o to +158oF (-30o to +70oC)

Process : 250oF (121oC0 if ambient air temp.Temp Max : is below 150oF (65oC)

Power : Provided by FDC1000 controlRequirement : Console, low voltage

Process Seal : TFE Teflon

Process connection : 1 1/4” NPT (flush mount with half coupling)

Conduit Connection : 3/4” NPT

Detection : Up to 10’

Range : depending on target

Interconnect : 4 conductor cable to FDC1000

Wiring : Control console

Indicators : Green LED - powerRed LED - loop current

Emission : 24.125 GHz, less than ImW/cm2(OSHA limit is 10mW/cm)2

Approval Pending : Intrinsically safe when connected toFDC1000

control unit, class II groups E, F & G

CONTROL CONSOLE

Enclosure : 8” x 6” x 4” fiberglassNEMA 4X, 12, 13, flange mount

Operating To : -31o to +158oF (-35o to +70oC)

Power requirement : 115 VAC 50/60 Hz, 5VA (230 VAC available)

Output : DPDT dry contacts, 5A @ 240 VAC,or 30 VDC

Indicators : Green LED - powerRed LED - loop faultYellow LED - sence flowRed LED - alarm

Interconnect wiring : 4 conductor cable to FDS1000 sensor,intrinsically safe

Sensitivity adjustment : High/low selectable,single turn adjustment

Time : FLOW delay, single turn 0.1 - 15 seconds

Alarm Fail-Safe : Switch selectable FLOWor NO FLOW

Approvals Pending : Ordinary locationsIndustrial control equipment

Page 12: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

JO-B

ELL

Jo-Bell LIQUID LEVEL CONTROL

TYPE MT

• Internal side mount• Pressures to 600 PSIG• Temperature to 400oF• SP.Gr as low as 0.6

TYPE B

• Internal top mount• Pressures to 300 PSIG• Temperature to 400oF• Sp. Gr. as low as 0.8

TYPE CB

• External side mount• Pressures to 3000 PSIG• Temperature to 750oF• SP.Gr as low as 0.375

TYPE DA

External side mount •Pressures to 600 PSIG •Temperature to 750oF •SP.Gr as low as 0.375 •

TYPE S

External side mount •Pressures to 1500 PSIG •

Temperature to 750oF •SP.Gr as low as 0.375 •

TYPE F

External side mount •Pressures to 1500 PSIG •

Temperature to 250oF •SP.Gr as low as 0.5 •

TYPE R

• External side mount • Temperature to 400oF

• Pressures to 250 PSIG • SP.Gr as low as 0.8

TYPE PS

• Internal side mount • Temperature to 250oF•Pressures to 600 PSIG• SP.Gr as low as 0.6• Pneumatic operation

SWITCHES

Precision, snap action, dry-contact • pneumatic; and solid state •

TYPE FL

Internal top mount •Pressures to 2500 PSIG •

Temperature to 250oF •SP.Gr as low as 0.6 •

TYPE MT-2TA

External side mount •Pressures to 600 PSIG •Temperature to 400oF •

SP.Gr as low as 0.7 •

TYPE KC

External top mount •Pressures to 300 PSIG •Temperature to 750oF •

SP.Gr as low as 0.5 •

TYPE AF & ASF

Internal side mount •Pressures to 300 PSIG •Temperature to 400oF •

SP.Gr as low as 0.5 •

TYPE KT

• Internal top mount• Pressures to 150 PSIG• Temperature to 750oF• Sp. Gr. as low as 0.75

TYPES A

• Internal side mount• Pressures to

500 PSIG• Temperature

to 400oF• SP.Gr as low as 0.5

Page 13: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

ASYB

CO

RÈGLE ÉLECTRONIQUE

LECTURE INSTANTANNÉE DE LA TEMPÉRATURE

Deux opérations en une:

• La prise de la température de l’essence contenue dans vos réservoirs

• La lecture du niveau de l’essence (façon traditionnelle)

• En raccordant le boîtier électronique à la règle thermomètre,l’afficheur vous indique en quelques secondes le degré detempérature de vos stocks

• Toutes les composantes électroniques sont isolées, sécuritaires et répondent aux normes de l’industrie

RÈGLE DE JAUGE EN BOIS FRANC

• Mesure exacte du niveau

• Protégée et renforcée à une extrémité par un embout enpolyuréthane qui résiste à l’action corrosive de l’essence et amortit la chute, évitant les dommages possibles aux réservoirs.

• Aucun élément de la règle ne peut provoquer d’électricité statique, ce qui en fait un instrument que l’on utilise en toute sécurité.

• Permet de prévenir les fuites d’essence et de gérer adéquatement vos inventaires tout en respectant l’environnement.

• Disponible en centimètre et en pouce

MODÈLE ÉCONOMIQUE

• Une règle de qualité standard ayant à une extrémité un ajout de nylon

Page 14: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

PIPE INSPECTION - LOCATION SYSTEM Gen-Eye2

COMMAND MODULE : PORTABLE CONTROL CENTER

No need to worry about an expensive TV and VCR bouncingaround in your truck. The Gen-Eye Command Module packs a 9”color TV and VCR combination into a compact, fully padded design- for maximum protection from shock and abuse.

The Gen-Eye Command module is guaranteed to make your jobeasier. The waterproof, fan cooled, high impact plastic carrying caseoperates in any of three positions: on its back, at a 45 degree angle,or a 90 degree angle - for convenient viewing from virtually anywork angle. Bothered by glare? Just snap on the handy four sidedsun shield to block bright light from any direction.

Dimmer Control

It lets you adjust the light level of the camrera’s LED’s to match the size and reflectivity of the pipe you’re working in.

Picture Inverter

No more standing on your head when the camera turns upside down.Just push the invert button and the picture is right side up again.

Built-In Voice Over Unit

Internal microphone and push on/push off button let you add commen-tary to the videos you give to your customers. Or get the optional externalmicrophone for noisy environments.

Built-In On-Screen Distance Counter • in feet or meters

Lets you keep track of the amount of push rod you’ve fed into the line.It helps you zero in on the area to start locating the camera.

Built-in Titler

You get two lines, 27 characters each, to add your company name andphone number to every video you make. Make sure your customersrememberwho did the job.

On-Screen Date and Time Stamp

You can document the day and time of each job for your records. Turnvideos into legal documents.

Built-In Camera Transmitter

No separate components to install or wire. The transmitter is built into the control panel. Just push the button to turn it on.

AC/DC Switchable

A 12 volt power inverter allows you to operate in the field with truck power alone.

Extra Storage Space

In the command module lid, there’s room for the power cord, sunshield and optional full scale video titler.

Other Standard Features Include

Panel mount fuses and a compartment under the TV/VCR that holds two tapes and the power converter. GE

NERA

LW

IRE

SPRI

NG

Page 15: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

TWO SKID DESIGNS

Skids keep the camera centered and riding higher in the pipe for a better view. They also reduce drag onlonger runs. A unique trap skid that protects the LED casing from abrasion as it slides through cast iron

P-traps comes with each camera system. An optional 3-in-1 skid assembly easily adapts to 3 differentpipe diameters - 4”, 6” and 8” - is also available.

THE MINI CAMERA

Spot problems in vents, laterals, laundry drains and more. Explore 4” lines through roof vents, slidethrough 3” cast-iron P-traps, 2” plastic P-traps, and 1 1/2” 90 degree bends with ease. Its fifteen high

intensity red LED’s spread the light evenly so you can see clearly in 1 1/2” through 6” lines.

THE COLOR CAMERA

At just 1.7” in diameter, this camera gives you a sharp picture in 2” through 12” lines. Its twenty-oneultra bright white LED lights give you plenty of light in up to 12” lines. Ideal for dye-testing, or to see

what type of pipe you are in. Black and white and color cameras are interchangeable so you can upgradeat any time.

Gen-Eye 2 PIPE INSPECTION - LOCATION SYSTEM

SMALL SIZE REELS

The standard reel holds up to 400 ft. of push rod in a sturdy framewith a convenient handle set at the right height. 7” wheels ensureeasy transport to and from the job. The mini reel carries up to 200ft. of push rod in a compact frame for easy handling without takingup too much room in your truck. You can even use mini reel on thestandard frame. Saves you money, too.

GENE

RAL

WIR

ESP

RING

Page 16: LF SERIES PREMIUM - asybco.com · LF SERIES PREMIUM ASYBCO LOW PRESSURE 300 SERIES LF SERIES QUALITY PRESSURE GAUGES. DUPLEX DIFFERENTIAL 3A SANITARY GAUGES Available in following

PIPE INSPECTION - LOCATION SYSTEM Gen-Eye2

DIGITAL LOCATOR

The Gen-Eye Pipe Locator uses high tech digital technology to tell you instantly the depth of the pipe downto the inch. With the push of a button, you can locate castiron pipe to a depth of 10 ft. and plastic and clay pipe to 20 ft.

NO GUESSWORK INVOLVED

The Gen-Eye Digital Locator lets you know exactly where the problems are. 100 sensitivity levels let you home in onthe transmitter’s signal. The LCD display panel produces aclear digital readout, as well as a graphic display and anaudible tone. It’s faster and more precise than analog locators. The Gen-Eye Locator lets you locate almost anything underground with its built-in three-way signalfinder. You can find the Gen-Eye camera even when it’sdeep inside cast iron pipe. When you turn on the digitallocator, it looks for a 512 hz signal transmitted from theGen-Eye camera.

Switch the locator to 60 hz and you can locate undergroundpower lines before you start digging. Switch again and you can locate gas lines, fiber optic cables, and CATV cableswith the optional 65 khz transmitter.

LOCATORS SPECIFICATIONSOperating modes • frequency :

Camera locator / 512 hz Pipe locator / 65 khzPower line locator / 60 hzDynamic range :

92 dbDepth range :

20 ft. (6 m) 10 ft. (3 m) in cast iron pipeSearch Antennas :

2 dual wound symmetrical response.Indicators :

LCD Digital signal read-out, graphic display,audible tone, digital depth indicator battery status.Locator Weight :

4.8 lbs. / 2.2 kgLocator Batteries :

12 x AA (30 hrs. of life at 68 oF)

THE GEN-EYE 2 TOTAL SYSTEM

The Gen-Eye Video Pipe Inspection/Location System gives your operation a new dimension. Until now you’ve been inspecting and locating pipes while working in the dark. The Gen-Eye system opensyour eyes with full spectrum of cameras reels plus a powerful digital locator.

Camera Specification Mini Camera Color CameraLine Capacity : 1 1/2” to 6” (3.8 cm to 15 cm) 2” to 12” (5 cm to 30 cm)Maximum Distance : 200 ft. (61 m) 400 ft (122 m)Operating Depth : 350 ft (150 psi) 350 ft (150 psi)Resolution : 380 (H) x 380 (V) 570 (H) x 495 (V)Pixel : 512 (H) x 492 (V) 768 (H) x 494 (V)Sensitivity : 0.5 Lux 0.3 LuxLighting : 15 Ultra Bright LEDs 21 Ultra Bright LEDs

18 000 Mcd Bright 42 000 Mcd BrightCamera Dimensions : 1” x 2.07” 1.68” x 2.7”

(25 mm x 53 mm long) (43 mm x 69 mm long)Push-Rod Diameter : .35” (9 mm) .47” (12 mm)Slip Ring : Litton Slip Ring Capsule Litton Slip Ring CapsuleReel and Frame Dimensions:17 1/2” L x 10 1/2” W x 22 1/2” H 25 1/2” L x 12” W x 33” H

(44.4 cm x 26.6 cm x 57 cm) (64.7 cm x 30 cm x 83.8 cm)TV / VCR Case Dimensions: 20” L x 16” W x 20” H 20” L x 16” W x 20” H

(50.8 cm x 40.6 cm x 50.8 cm) (50.8 cm x 40.6 cm x 50.8 cm)VCR Video Format : VHS in NTSC or PAL VHS in NTSC or PALPower : 110 v / 60 hz AC, 12v DC 110 v / 60 hz AC, 12v DCOperating Temperature : 14oF to 122oF / -10oC to 50oC 14oF to 122oF / -10oC to 50oC

GENE

RAL

WIR

ESP

RING