lg fan coil unit

25
LG AIR CONDITIONING We always pursue highly advanced t echnologies to improve the quality of your life. Enjoy a clean, quiet & comfortable life with LG Air Conditioners.    w    w    w  .      l     g     e     a      i     r     c     o     n  .     c     o     m LG Electronics Air Conditioning Marketing 20 Yeouido-dong, Yeongdeungpo-gu, Seoul 150-721, Korea Phone: 82-2-3777-1114 E-Mail : [email protected]m http://www.lge.com F  o r  c  o n t  i  n  u  a l   p r  o  d  u  c t   d  e v  e l   o  p m  e t   , L  G r  e  s  e r v  e  s t  h  e r i   g h t  t   o  c h  a n  g  e  s  p  e  c i  f  i   c  a t  i   o n  s w i  t  h  o  u t  n  o t  i   c  e .  ©  L  G E l   e  c t  r  o n i   c  s I   c . P r i  n t   e  d i  n K  o r  e  a 2  0  0 9 ME-CA091

Upload: raghuragoo

Post on 12-Oct-2015

1.160 views

Category:

Documents


91 download

DESCRIPTION

details of fan coil unit

TRANSCRIPT

  • LG AIR CONDITIONINGWe always pursue highly advanced technologies to improve the quality of your life. Enjoy a clean, quiet & comfortable life with LG Air Conditioners.

    ww

    w.l

    ge

    air

    co

    n.c

    om

    LG Electronics Air Conditioning Marketing20 Yeouido-dong, Yeongdeungpo-gu, Seoul 150-721, KoreaPhone: 82-2-3777-1114 E-Mail : [email protected]://www.lge.com

    F

    o

    r

    c

    o

    n

    t

    i

    n

    u

    a

    l

    p

    r

    o

    d

    u

    c

    t

    d

    e

    v

    e

    l

    o

    p

    m

    e

    n

    t

    ,

    L

    G

    r

    e

    s

    e

    r

    v

    e

    s

    t

    h

    e

    r

    i

    g

    h

    t

    t

    o

    c

    h

    a

    n

    g

    e

    s

    p

    e

    c

    i

    f

    i

    c

    a

    t

    i

    o

    n

    s

    w

    i

    t

    h

    o

    u

    t

    n

    o

    t

    i

    c

    e

    .

    L

    G

    E

    l

    e

    c

    t

    r

    o

    n

    i

    c

    s

    I

    n

    c

    .

    P

    r

    i

    n

    t

    e

    d

    i

    n

    K

    o

    r

    e

    a

    2

    0

    0

    9

    ME-CA091

  • Contents

    LG Electronics, The Worlds Best Seller

    06

    Single Packaged Type

    14

    Ducted Split Type

    20

    Fan Coil Unit

    24

    MULTI M & M DX

    36

    Ceiling Concealed DuctType

  • Models Line upThe Worlds Number 1 Choice in Air Conditioners!

    Single Packaged Type Ducted Split Type

    Btu/h

    3~6tons3~6tons 7.5~30tons 3~5tons 7.5~12.5tons 15~20tons

    7,000 9,000 12,000 18,000 22,000 24,000 26,000 30,000 36,000 42,000 48,000 60,000 80,000 100,00072,000 150,000

    Ceiling Concealed Duct Type

    Fan Coil Unit Type

    * The exact appearance of products may vary from the images shown here.

    Single Split Wall Mounted Type

    Ceiling Cassette Type

    Floor Standing Type

    Ceiling and Floor Type

    Ceiling Suspended Type

    18,0007,000Btu/h 9,000 12,000 18,000 22,000 24,000 26,000 30,000 36,000 42,000 48,000 60,000 80,000 100,00072,000 150,000

  • Ce

    i

    l

    i

    n

    g

    C

    o

    n

    c

    e

    a

    l

    e

    d

    D

    u

    c

    t

    T

    y

    p

    e

    06

    07

    Ceiling Concealed Duct TypeLG AIR CONDITIONERS 2009

    Ceiling Concealed Duct TypeHidden in the ceiling, this model is designed for buildings that require floorlevel air conditioning for many individual rooms or large areas, likerestaurants, concert halls and hotels. Installation is not restricted by lightingfixtures or the building layout, and interior renovation is made easy byinstalling ventilation diffusers.

    The air volume and sound level is kept constant as designedregardless of changes in E.S.P.(External Static Pressure)E.S.P. technology - Optimizes Duct Installation- Keeps Capacity & Sound Levels within desired ranges- Reduces the number of models

    Phase control motor technology reduces installation costs. Thedesired air flow is obtained by adjusting the phase motor duringinstallation of the product, giving you more flexibility whensetting up your duct system. The E.S.P can be adjusted linearlyfrom 0 to 10mmAq.

    *E.S.P: External Static Pressure

    The integrated PLASMA Air Purifying System removesmicroscopic contaminants and dust, eliminates offensive odorsand prevents allergic reactions. It can also be used as an air-purifying unit only, without running the air conditioner.

    Evaluated by CSIRO Australia (DBCE Doc 98/204)Tested by Korean Food Research Institute and Japanese EnvironmentalCentre and Yonsei Univ. College of Medicine. (Allergy Research Lab.)

    PLASMA Air Purifying System (Accessory)

    Respirable particles from 5 cigarettes in a sealedroom removed by the LG Plasma Air PurifyingSystem.

    LG's Plasma Air Purifying unit effectively removeshigh concentrations of tobacco odors (Confirmedin sensory tests carried out in Korea and Japan.)

    In clinical tests, the LG Plasma Air Purifying Systemreached a satisfaction level of 82% .

    Dust Reduction

    Deodorization

    Anti-Allergy

  • Ce

    i

    l

    i

    n

    g

    C

    o

    n

    c

    e

    a

    l

    e

    d

    D

    u

    c

    t

    T

    y

    p

    e

    08

    09

    1) Basic Operation- With a temperature sensor controlling every diffuser, the

    temperature for each zone can be monitored and adjustedautomatically.

    2) Control Features- If every damper is closed, the compressor and outer fan are

    turned off, to protect the compressor.

    1) Basic Operation- Linking several units, one Central Control Unit can manage

    and turn off several units individually or as a group.

    2) Control Features - Each indoor unit is connected to a Central Control Unit via a

    data communication cable and can be operated or turned offindividually or together with a group of units with the centralcontroller.

    - The Central Control Unit can manage up to 8 * 16 indoorunits.

    Ceiling Concealed Duct TypeLG AIR CONDITIONERS 2009

    Zone Controller (Accessory)

    - Eliminates waste of electricity in standby mode.- Electricity is wasted when an appliance is connected to an

    outlet, even though the appliance is turned off. - Development of a super power-saving SMPS

    (Swiching Mode Power Supply)- Minimal standby power consumption

    (90% reduction of standby power).- No need to pull the main power plug when the appliance is not

    in use.

    Zero standby power consumption

    Central Controller (Accessory)

    LG Air Conditioners (Cassette and Duct-type models) can beinstalled at long distances (max 50m) and high heightdifferences (30m) from the outdoor unit.

    Plz refer to the picture below.

    Ceiling Concealed Duct TypeLG AIR CONDITIONERS 2009

    Long Distance Piping High Elevation

    Need not control on each times at big diurnal range areas.

    Auto Changeover

    The dual thermistor control regulates the difference betweenthe indoor temperature and the temperature of the conditionedair by monitoring both temperatures, to ensure a uniform roomtemperature. The sensor readings are adjusted for optimumroom temperature.

    Two Thermistor Control

    If desired, you can set operation times for up to one week inadvance.

    Timer-controlled Operation

    The High Head Drain Pump pumps water up to 700mm high forsmooth drainage.

    High Head Drain Pump (Accessory)

    50m 30m

    Heating

    Dehumidifying

    Cooling

    Micro Processor

    Analyze 3 Temperature

    Measure Periodically

    Target Temperature

    Outdoor Temperature

    Indoor Temperature

    LCD Wired Remote Controller

    24-Hour ON/ OFF Timer with 1 hour intervals

    TEST RUN Mode

    Self-Diagnosis feature

    3-Step Fan Speed selection

    Operation Indicator

    Room Temperature Display

    Only 20mm thick

    OptionWireless Remote controller

    Pipe fixture

    FlexibleDrain Hose

    Drain pump

    Wall

    Drain pipe

    700mm

    Zone A

    Zone C

    Zone D

    Zone B

    On Off

    1 2 3 4

    5 6 7 8

    9 10 11 12

    13 14 15 16

    1 2 16

    Controller#1

    Controller#2

    On Off

    1 2 3 4

    5 6 7 8

    9 10 11 12

    13 14 15 16 Controller#8

    On Off

    1 2 3 4

    5 6 7 8

    9 10 11 12

    13 14 15 16

    1 2 16

  • 1) Basic Operation - Linking several units, one Group Control Unit can manage a

    number of indoor units.

    2) Control Features- Through a data cable connected to each indoor unit, a group

    of units can be managed from the group controller. - The Group Control function is enabled by cutting an optional

    jump wire in the wired remote control, which prevents datacollision.

    - One Group Control Unit can control up to 16 indoor units.

    Ceiling Concealed Duct TypeLG AIR CONDITIONERS 2009

    Group Control

    LGs Outdoor Heat Exchanger is coated with a gold-coloredanti-corrosive epoxy treatment on the aluminum coil, toprevent corrosion. This maintainsexcellent heat transferproperties of the coil for an extended time, whereas non-GoldFin coils progressively lose efficiency due to surfacecorrosion. Gold Fin fin is perfect for areas with high pollutionor locations exposed to saltwater spray from the sea.

    Gold Fin Anti Corrosion

    Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)

    Features

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TB-H246HSS0

    24,000

    24,000

    1, 220~240,50

    2,700 / 2,700

    12.0 / 12.0

    8.89

    2.61

    18/16.5/14

    2.7

    37/35/33

    55

    6

    3*2.5

    5*0.75*220

    880*260*450

    870*800*320

    35/60

    44/85

    6.35/15.88

    LB-C246HSS1

    24,000

    -

    1, 220~240,50

    2,750 / -

    12 / -

    8.73

    -

    18/16.5/14

    2.7

    37/35/33

    55

    6

    3*2.5

    4*0.75*220

    880*260*450

    870*800*320

    35/60

    44/85

    6.35/15.88

    TB-H186HSS0

    18,000

    18,000

    1, 220~240,50

    2,020 / 2,020

    9.5 / 9.5

    8.91

    2.90

    16/14.5/13

    1.5

    36/34/32

    55

    6

    3*2.5

    5*0.75*220

    880*260*450

    870*655*320

    35/55

    52/107

    6.35/15.88

    LB-C186HSS1

    18,000

    -

    1, 220~240,50

    2,020 / -

    9.5 / -

    8.91

    -

    16/14.5/13

    1.5

    36/34/32

    55

    6

    3*2.5

    4*0.75*220

    880*260*450

    870*655*320

    35/55

    52/107

    6.35/15.88

    Ceiling Concealed Duct Type

    LB-C186HSS1 TB-H186HSS0LB-C246HSS1 TB-H246HSS0

    10 11

    2 16........

    ........

    Gold Coated Aluminum Uncoated Aluminum

    LG Gold FinCorrosion Free

    ConventionalStarting to corrode

    After 15 Days After 15 Days

    Salt Spray Test for 15 Days

  • Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)

    Features

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TB-H366GSS0

    36,000

    36,000

    1, 220~240,50

    4,100 / 4,100

    18.8 / 18.8

    8.78

    2.57

    32/29/26.5

    3.5

    43/42/40

    58

    8

    3*5.5

    5*0.75*220

    1,180x298x450

    870x1,038x320

    38/78

    30/63

    6.35/15.88

    LB-C366GSS1

    36,000

    -

    1, 220~240,50

    4,100 / -

    18.8 / -

    8.78

    -

    32/29/26.5

    3.5

    43/42/40

    58

    8

    3*5.5

    4*0.75*220

    1,180x298x450

    870x800x320

    38/70

    31/69

    9.52/15.88

    TB-H306GSS0

    30,000

    30,000

    1, 220~240,50

    3,400 / 3,400

    15 / 15

    8.82

    2.59

    28/26/24

    3

    43/42/40

    56

    8

    3*3.5

    5*0.75*220

    1,180x298x450

    870x800x320

    38/65

    31/69

    6.35/15.88

    LB-C306GSS1

    30,000

    -

    1, 220~240,50

    3,600 / -

    17.0 / -

    8.33

    -

    28/26/24

    3

    43/42/40

    56

    8

    3*3.5

    4*0.75*220

    1,180x298x450

    870x800x320

    38/65

    31/69

    6.35/15.88

    Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)

    Features

    12 13

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TB-H428GSS0

    42,000

    42,000

    3, 380~415, 50

    5,100 / 5,400

    8 / 8.5

    8.24

    2.41

    32/29/26.5

    4.5

    43/42/40

    59

    8

    5*2.5

    5*0.75*220

    1,180x298x450

    900x1,165x370

    38/95

    27/55

    9.52/19.05

    LB-C428GSS1

    42,000

    -

    3, 380~415, 50

    5,000 / -

    7.8 / -

    8.40

    -

    32/29/26.5

    4.5

    43/42/40

    59

    8

    5*2.5

    4*0.75*220

    1,180x298x450

    870x1,038x320

    38/78

    30/63

    9.52/19.05

    TB-H368GSS0

    36,000

    36,000

    3, 380~415, 50

    4,100 / 4,100

    6.3 / 6.3

    8.78

    2.57

    32/29/26.5

    3.5

    43/42/40

    58

    8

    5*2.5

    5*0.75*220

    1,180x298x450

    870x1,038x320

    38/78

    30/63

    6.35/15.88

    LB-C368GSS1

    36,000

    -

    3, 380~415, 50

    4,100 / -

    6.3 / -

    8.78

    -

    32/29/26.5

    3.5

    43/42/40

    58

    8

    5*2.5

    4*0.75*220

    1,180x298x450

    870x1,038x320

    38/78

    30/63

    6.35/15.88

    Ceiling Concealed Duct Type

    LB-C306GSS1 TB-H306GSS0LB-C366GSS1 TB-H366GSS0

    Ceiling Concealed Duct Type

    LB-C368GSS1 TB-H368GSS0LB-C428GSS1 TB-H428GSS0

  • Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)

    Features

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TB-H608RSS0

    56,000

    58,000

    3, 380~415, 50

    6,800 / 6,250

    10.5 / 9.8

    8.24

    2.72

    50/45/40

    5.5

    49/47/45

    60

    10

    5*3.5

    5*1.25*220

    1,230x380x590

    900x1,165x370

    52/105

    24/48

    12.7/19.05

    LB-C608RSS1

    56,000

    -

    3, 380~415, 50

    6,800 / -

    10.5 / -

    8.24

    -

    50/45/40

    5.5

    49/47/45

    60

    10

    5*3.5

    4*1.25*220

    1,230x380x590

    900x1,165x370

    52/105

    24/48

    12.7/19.05

    TB-H488RSS0

    48,000

    48,000

    3, 380~415, 50

    5,600 / 5,000

    8.7 / 7.7

    8.57

    2.81

    40/35/30

    5

    46/44/42

    59

    10

    5*3.5

    5*1.25*220

    1,230x380x590

    900x1,165x370

    52/95

    24/48

    9.52/19.05

    LB-C488RSS1

    48,000

    -

    3, 380~415, 50

    5,750 / -

    9 / -

    8.35

    -

    40/35/30

    5

    46/44/42

    59

    10

    5*3.5

    4*1.25*220

    1,230x380x590

    900x1,165x370

    52/95

    24/48

    9.52/19.05

    Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)

    Features

    14 15

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    LB-C246HSA4

    24,000

    -

    1, 220~240, 50

    2,880 / -

    13 / -

    8.6

    -

    18/16.5/14

    2.50

    37/35/33

    57

    6

    3*3.5

    4*0.75

    880x260x450

    870x655x320

    35/55

    52/106

    6.35/15.88

    LB-C186HSA4

    18,000

    -

    1, 220~240, 50

    2,000 / -

    9.2 / -

    9.0

    -

    16/14.5/13

    2.0

    36/34/32

    55

    6

    3*3.5

    4*0.75

    880x260x450

    801x555x262

    35/50

    63/134

    6.35/15.88

    Ceiling Concealed Duct Type

    LB-C488RSS1 TB-H488RSS0LB-C608RSS1 TB-H608RSS0

    Ceiling Concealed Duct Type

    LB-C186HSA4 LB-C246HSA4

  • Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)

    Features

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    LB-C428GSA0

    42,000

    -

    3, 380~415, 50

    5,000 / -

    7.8 / -

    8.4

    -

    32/29/26

    4.5

    42/40/38

    60

    8

    4*2.5

    4*0.25

    1,180x298x450

    870x1,038x320

    38/78

    34/73

    9.52/15.88

    LB-C366GSA0

    36,000

    -

    1, 220~240, 50

    4,500 / -

    20.0 / -

    8

    -

    32/29/26

    3.50

    42/40//38

    59

    8

    3*5.5

    4*0.75

    1,180x298x450

    870x800x320

    38/70

    34/73

    9.52/15.88

    LB-C306GSA0

    30,000

    -

    1, 220~240, 50

    3,500 / -

    16.0 / -

    8.6

    -

    28/26/24

    3.00

    42/40/38

    60

    8

    3*3.5

    4*0.75

    1,180x298x450

    870x800x320

    38/60

    34/73

    6.35/15.88

    Gold Fin Anti Corrosion et CoolTM Auto Cleaning Auto Restart Natural Wind By CHAOS Swing Wireless Remote Controller Quiet Operation Sleep Mode Auto Operation One-Touch Air Filter(Anti-Bacteria) Healthy Dehumidification 24-Hour ON/OFF Setting Timer

    Features

    16 17

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    Power Input Cooling / Heating W

    Running Current Cooling / Heating A

    Performance

    EER Cooling Btu/hr.W

    COP Heating W/W

    Air Circulation Indoor(H/M/L) CMM

    Moisture Removal l /hr

    Noise Level Indoor(H/M/L) dB(A)3

    Outdoor Max dB(A)3

    External Static Pressure mmAq

    Cable Main No.*(mm2)*Max L.(m)

    Conneting No.*(mm2)*Max L.(m)

    Installation & Stuffing

    Net Dimensions Indoor mm

    (WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40ft

    Service Valve Liquid/Gas (mm)

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    LB-C608RSA0

    60,000

    -

    3, 380~415, 50

    6,500 / -

    10.2 / -

    9.2

    -

    50/45/40

    5.50

    46/44/42

    61

    10

    4*3.5

    4*1.25

    1,230x380x590

    900x1,165x370

    52/105

    24/49

    12.7/19.05

    LB-C488RSA0

    48,000

    -

    3, 380~415, 50

    5,100 / -

    8.0 / -

    9.4

    -

    40/35/30

    5.00

    44/42/40

    62

    10

    4*3.5

    4*1.25

    1,230x380x590

    900x1,165x370

    52/95

    24/49

    9.52/15.88

    Ceiling Concealed Duct Type

    LB-C306GSA0 LB-C366GSA0LB-C428GSA0

    Ceiling Concealed Duct Type

    LB-C488RSA0 LB-C608RSA0

  • Si

    n

    g

    l

    e

    P

    a

    c

    k

    a

    g

    e

    d

    T

    y

    p

    e

    18

    19

    Single Packaged TypeLG AIR CONDITIONERS 2009

    Single Packaged TypeEconomical and user-friendly model, designed for medium-sized housesand shops. Features include a number of operation modes, auto restart anda washable anti-bacterial filter.

    The unit can be installed outdoors to save valuable indoorspace, or in locations where no ceiling space is available.Ground or roof installation options provide total flexibilityaccording to your requirements.

    Easy Installation

    The all-in-one design, with all access panels located on oneside of the unit and color-coded wiring, greatly facilitatesmaintenance and service.

    Easy Maintenance & Service

    All units are designed for reverse-cycle operation, which meanselectric heating functions can be added by specialized dealers.This model also allows complete control over fresh air intake,ratio of air purification, as well as monitoring and automaticzone control (additional features available from specializeddealers), through the powerful LG control system.

    Additional functions available with ductsystem

    Selecting an air conditioner with the right capacity is veryimportant. A unit that is too small or too big will not only affectyour comfort, but may also unnecessarily increase your initialpurchasing cost and operational expenses. The LG cooling loadcalculation program helps you choose the right system for yourspecific needs.

    LGs Cooling Load Calculation Program

    A duct system allows you to freely control air-circulation.

    Free & Easy Air-Circulation

    Roof Jack Installation Roof Curb Installation Slab-on-Ground Installation

    Typical Installation

  • Compact & Lightweight Design U-shape Air Flow Safety Condenser Fin Guard Forklift Base rail Easy access Panel Time Delay Relay is Standard Component Low Pressure Switch is Standard Component Durable Painted Steel Cabinet Scroll Compressor with internal high-pressure & Over-current Protector Factory Charged Refrigerant Direct-drive multi-speed PSC Blower Motor Direct-drive PSC Condenser Fan Motor Phase reversal Protection

    Features

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions (WxHxD) mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TK-C0608HA0

    59,900

    -

    3, 380~415,50

    21.6

    6,400

    56.7

    8.0

    1,111x824x734

    140

    30/64/96

    TK-C0488HA0

    48,400

    -

    3, 380~415,50

    17

    4,900

    45.3

    7.9

    1,111x824x734

    120

    30/64/96

    TK-C0368HA0

    35,700

    -

    3, 380~415,50

    13.2

    4,000

    34

    7.7

    1,111x824x734

    110

    30/64/96

    Wired LCD Remote Controller Easy Installation Auto Restart Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System

    Features

    20 21

    ModelCapacity

    Cooling Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions (WxHxD) mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TK-C0908H00

    96,000

    -

    3, 380~415,50

    24.7

    9,500

    81.3

    8.5

    1,784x1,147x1,202

    310

    8/18/18

    TK-C0728H00

    72,000

    -

    3, 380~415,50

    22.8

    8,600

    73.1

    7.6

    1,784x1,147x1,202

    260

    8/18/18

    Single Packaged Type

    TK-C0368HA0 TK-C0488HA0TK-C0608HA0

    Single Packaged Type

    TK-C0728H00 TK-C0908H00

    * The exact appearance of products may vary from the images shown here. * The exact appearance of products may vary from the images shown here.

  • Washable Anti-bacteria Filter Wired LCD Remote Controller Easy Installation Oversized moter (Accessory) Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Auto Restart

    Features

    ModelCapacity

    Cooling (Gross) Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions (WxHxD) mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TK-C1508H00

    129,600

    -

    3, 380~415,50

    33

    15,600

    155

    8.6

    2,110x1,250x1,280

    400

    4/9/18

    TK-C1208H00

    112,600

    -

    3, 380~415,50

    24.9

    13,500

    104

    8.5

    2,110x1,250x1,280

    400

    4/9/18

    Washable Anti-bacteria Filter Wired LCD Remote Controller Easy Installation Oversized moter (Accessory) Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Auto Restart

    Features

    22 23

    ModelCapacity

    Cooling (Gross) Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions (WxHxD) mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    GK-C3608H00

    360,000

    -

    3, 380~415,50

    86.4

    33,000

    311

    10

    2,688x1,720x2,220

    1,070

    2/4/4

    GK-C1808C00

    175,000

    -

    3, 380~415,50

    52.7

    18,000

    165

    9.2

    2,230x1,244x1,540

    550

    3/7/14

    GK-C2108C00

    197,000

    -

    3, 380~415,50

    57

    20,500

    198

    9.2

    2,230x1,244x1,540

    600

    3/7/14

    GK-C2408C00

    238,900

    -

    3, 380~415,50

    68.4

    25,000

    226

    9.2

    2,893x1,250x2,200

    870

    1/4/8

    GK-C3008C00

    280,400

    -

    3, 380~415,50

    80.1

    28,500

    280.0283

    9.2

    2,893x1,250x2,200

    870

    1/4/8

    Single Packaged Type

    TK-C1208H00 TK-C1508H00

    Single Packaged Type

    GK-C1808C00 GK-C2108C00GK-C2408C00 GK-C3008C00GK-C3608H00

    * The exact appearance of products may vary from the images shown here. * The exact appearance of products may vary from the images shown here.

  • Ducted Split TypeEconomical and user-friendly model, designed for medium-sized housesand shops. Features include a number of operation modes, auto restart anda washable anti-bacterial filter.

    4way Convertibility-horizontal(Left & right), up-flow, down-flow Plastic drain Pan High efficient Evaporator Coil Galvanized Steel with painting Washable and Anti-fungus Filter Multi-speed blower Time delay PCB 220V primary & 24V secondary transformer Defrost sensor Hi-Reliability Compressor Factory supplied charge of R-22 Compressor internal overload protection Internal pressure relief valve provides high pressure protection for compressor Outside pressure taps for refrigerant system check.

    Features

    ModelCapacity

    Cooling (Gross) Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions Indoor mm(WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TN-C0368SA0

    37,000

    -

    3, 380~415,50

    9.7

    4,100

    21.6

    6

    470x1,014x480

    870x800x320

    59/65

    32/66/66

    TN-C0488SA0

    49,500

    -

    3, 380~415,50

    13.9

    5,000

    50.9

    6.2

    600x1,135x500

    900x1,135x370

    63/100

    12/26/26

    TN-C0608SA0

    60,000

    -

    3, 380~415,50

    16.5

    5,800

    53.8

    6.2

    600x1,135x500

    900x1,135x370

    65/115

    12/26/26

    Ducted Split Type

    TN-C0368SA0 TN-C0488SA0TN-C0608SA0

    25

    LED Wired Remote Controller

    Air Filter Guide

    Blower Housing Assembly

    A Type Indoor Coil

    Plastic Drain Pan

  • Compact Size Quick and Easy Service Panels Anti-fungus, Hygienic and Easy-to-Clean filter Convertible lnstallation Safety Condenser Fin Guard High/Low Static Driver Kit, Over Sized Motor(Accessory) LCD Wired Remote Control

    Features

    ModelCapacity

    Cooling (Gross) Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions Indoor mm(WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TN-C1208T00

    111,200

    -

    3, 380~415,50

    30

    11,800

    102

    6.3

    1,760x890x840

    1,330x1,570x740

    190/300

    6/15/19

    TN-C0908T00

    80,900

    -

    3, 380~415,50

    20

    8,100

    76.4

    6.0

    1,760x890x840

    855x1,570x740

    190/175

    6/15/22

    Compact Size Quick and Easy Service Panels Anti-fungus, Hygienic and Easy-to-Clean filter Convertible lnstallation Safety Condenser Fin Guard High/Low Static Driver Kit, Over Sized Motor(Accessory) LCD Wired Remote Control

    Features

    26 27

    ModelCapacity

    Cooling (Gross) Btu/hr

    Heating Btu/hr

    Electrical Data

    Power Supply ,V,Hz

    M.C.A(with standard motor) Cooling / Heating Amps

    Power Input Cooling / Heating W

    Performance

    Air Circulation Indoor CMM

    Sound Rating bell

    Installation & Stuffing

    Net Dimensions Indoor mm(WxHxD) Outdoor mm

    Net Weight Indoor/Outdoor Kg

    Stuffing Quantity Without S/Parts 20/40/40ft Hi

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    TN-C1508T00

    135,200

    -

    3, 380~415,50

    35

    13,200

    125

    8.0

    1,760x890x840

    1,130x1,180x1,100

    190/250

    7/14/19

    TN-C1808T00

    179,700

    -

    3, 380~415,50

    57.2

    20,400

    150

    8.0

    2,065x680x1,160

    1,640x1,130x880

    200/280

    7/14/19

    TN-C2408T00

    240,000

    -

    3, 380~415,50

    76.2

    27,200

    200

    8.0

    1,870x980x1,230

    1,840x1,130x970

    230/340

    7/14/19

    Ducted Split Type

    TN-C0908T00 TN-C1208T00

    Ducted Split Type

    TN-C1508T00 TN-C1808T00TN-C2408T00

  • Fa

    n

    C

    o

    i

    l

    U

    n

    i

    t

    28

    29

    Fan Coil UnitLG AIR CONDITIONERS 2009

    Fan Coil UnitThe FCU (Fan Coil Unit) is supplied with cold or hot water by the controlcenter and circulates indoor air through the cooling and heating coils.

    The structures using CAD & CAE technology helps users reduceinstallation spaces.Slim and compact design based on CAD/CAE systems enablesuser to reduce installation space.

    Slim & Compact Size

    PCM Fin coated with anti corrosive & hydrophilic layersprevents corrosion and make itself remains as like initialcondition, therefore it saves power & maintenance cost.Heat Exchanger fins are coated with anticorrosive & hydrophiliclayers. It prevents the corrosion of heat exchanger. Fins remainas new even after long time of operation and maintainsefficiency of heat exchanger constant.

    Durable & Energy Saving PCM Fin

    Easily removable motor & blower and removable panels helpusers maintain units more conveniently.Each unit is designed to occupy a minimum space. This feature,along with convenientwiring and piping connections, means reduces costs onrenovations or new construction sites.

    Easy Maintenance

    230230 260260

    LG (WxHxD):

    1,090x230x524

    The other companies (WxHxD):

    1,020x260x515

    LG PCM FIN The other companies UNCOATED AL

    230 260

  • Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System District Cooling / Low Static

    Features

    ModelPerformance

    Nominial Air Flow H / M / L CFM

    Nominial Total Capacity H / M / L Btu/h

    Water Flow Rate GPM(US)

    Water Pressure Drop kPa / ft.wg.

    Indoor Noise Level

    Noise Level L / M /H dB(A)

    Coil

    Tube Size inch(mm)

    No. of Rows, Columns & FPI

    Face Area sq.m

    Face Velocity m/s

    Motor

    Type

    No. of motor #

    Class

    Power Supply Ph/Hz/V

    Total Rating Input watt

    Fan

    Material

    Type

    No. of Fans #

    Water Content

    3 Rows Liter

    Drain Pan

    Drain Pan (Material / Thickness)

    Insulator (Meterial / Thickness)

    Filter

    Material

    No. of Filter

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    YBNC146GCA0

    1,422/1,195/948

    38,150/35,280/28,217

    4,840

    30,330 / 9,948

    38 / 43 / 48

    3 / 8 (9.52)

    4R 8C 11FPI

    0.345

    1.95

    3

    B

    1 / 50 / 220~240

    280

    5

    3.352

    1

    YBNC036ACA0

    416/354/283

    10,130/9,144/6,960

    1,320

    3,740 / 1,227

    32 / 35 / 40

    3 / 8 (9.52)

    4R 8C 11FPI

    0.122

    1.61

    1

    B

    1 / 50 / 220~240

    67

    2

    1.183

    1

    YBNC046BCA0

    508/424/341

    14,252/11,874/9,519

    1,850

    7,590 / 2,490

    28 / 34 / 40

    3 / 8 (9.52)

    4R 8C 11FPI

    0.142

    1.69

    1

    B

    1 / 50 / 220~240

    75

    2

    1.381

    1

    YBNC066CCA0

    640/512/430

    17,783/15,968/12,590

    2,270

    11,540 / 3,785

    35 / 40 / 43

    3 / 8 (9.52)

    4R 8C 11FPI

    0.189

    1.60

    1

    B

    1 / 50 / 220~240

    102

    2

    1.834

    1

    YBNC086DCA0

    869/736/577

    24,921/22,656/17,640

    3,190

    12,050 / 3,952

    35 / 40 / 44

    3 / 8 (9.52)

    4R 8C 11FPI

    0.244

    1.68

    2

    B

    1 / 50 / 220~240

    152

    3

    2.366

    1

    YBNC106ECA0

    1,100/924/742

    28,893/25,999/21,530

    3,650

    13,920 / 4,566

    35 / 40 / 44

    3 / 8 (9.52)

    4R 8C 11FPI

    0.284

    1.83

    2

    B

    1 / 50 / 220~240

    188

    4

    2.761

    1

    YBNC126FCA0

    1,242/1,048/848

    35,089/31,970/25,624

    4,460

    17,550 / 5,756

    37 / 41 / 45

    3 / 8 (9.52)

    4R 8C 11FPI

    0.325

    1.80

    2

    B

    1 / 50 / 220~240

    198

    4

    3.155

    1

    Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System District Cooling / HighStatic

    Features

    30 31

    Fan Coil Unit

    YBNC036ACA0 YBNC046BCA0YBNC066CCA0 YBNC086DCA0YBNC106ECA0 YBNC126FCA0YBNC146GCA0

    Fan Coil Unit

    YBNC126HDA0 YBNC146JDA0YBNC166KDA0 YBNC186KDA0YBNC206DLA0

    4 Rows Coil

    3 - Speed Permanent Split Capacitor Motor

    Galvanized Steel

    Centrifugal Fan (Forward Curve)

    Galvanized Steel / T0.8

    PE / T5.0

    Synthetic Nylon (optional Aluminum)

    ModelPerformance

    Nominial Air Flow H / M / L CFM

    Nominial Total Capacity H / M / L Btu/h

    Water Flow Rate (Middle) GPM(US)

    Water Pressure Drop (Middle) kPa / ft.wg.

    Indoor Noise Level

    Noise Level L / M /H dB(A)

    Coil

    Tube Size inch(mm)

    No. of Rows, Columns & FPI

    Face Area sq.m

    Face Velocity m/s

    Motor

    Type

    No. of motor #

    Class

    Power Supply Ph/Hz/V

    Total Rating Input (Middle) watt

    Fan

    Material

    Type

    No. of Fans #

    Water Content

    3 Rows Liter

    Drain Pan

    Drain Pan (Material / Thickness)

    Insulator (Meterial / Thickness)

    Filter

    Material

    No. of Filter

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    YBNC126HDA0

    1,348 / 1,115 / 1,051

    37,028 / 31,455 / 28,123

    3,800

    7,200 / 2,361

    50 / 53 / 59

    3 / 8 (9.52)

    4R 12C 13FPI

    0.237

    2.39

    2

    B

    1 / 50 / 220~240

    330

    2

    2.66

    1

    YBNC146JDA0

    1,513 / 1,338 / 1,196

    43,099 / 36,650 / 32,745

    4,520

    9,400 / 3,082

    51 / 55 / 60

    3 / 8 (9.52)

    4R 12C 13FPI

    0.274

    2.41

    2

    B

    1 / 50 / 220~240

    440

    2

    3.01

    1

    YBNC166KDA0

    1,702 / 1,562 / 1,296

    47,219 / 41,558 / 37,474

    5,120

    11,000 / 3,607

    49 / 55 / 59

    3 / 8 (9.52)

    4R 12C 13FPI

    0.329

    2.29

    2

    B

    1 / 50 / 220~240

    480

    2

    3.07

    1

    YBNC186KDA0

    1,901 / 1,674 / 1,428

    51,088 / 45,105 / 39,659

    5,560

    12,900 / 4,230

    51 / 57 / 59

    3 / 8 (9.52)

    4R 12C 13FPI

    0.329

    2.59

    2

    B

    1 / 50 / 220~240

    550

    2

    3.07

    1

    YBNC206DLA0

    2,089 / 1,928 / 1,638

    55,530 / 47,889 / 41,737

    5,900

    14,400 / 4,623

    53 / 58 / 62

    3 / 8 (9.52)

    4R 12C 13FPI

    0.411

    2.30

    2

    B

    1 / 50 / 220~240

    650

    2

    3.80

    1

    4 Rows Coil

    3 - Speed Permanent Split Capacitor Motor

    Galvanized Steel

    Centrifugal Fan (Forward Curve)

    Galvanized Steel / T0.8

    PE / T5.0

    Synthetic Nylon (optional Aluminum)

  • Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / Low Static

    Features

    ModelPerformance

    Nominial Air Flow H / M / L CFM

    Nominial Total Capacity H / M / L Btu/h

    Water Flow Rate GPM(US)

    Water Pressure Drop kPa / ft.wg.

    Indoor Noise Level

    Noise Level L / M /H dB(A)

    Coil

    Tube Size inch(mm)

    No. of Rows, Columns & FPI

    Face Area sq.m

    Face Velocity m/s

    Motor

    Type

    No. of motor #

    Class

    Power Supply Ph/Hz/V

    Total Rating Input watt

    Fan

    Material

    Type

    No. of Fans #

    Water Content

    3 Rows Liter

    Drain Pan

    Drain Pan (Material / Thickness)

    Insulator (Meterial / Thickness)

    Filter

    Material

    No. of Filter

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    YBNB146GAA0

    1,728/1,270/1,082

    48,621/43,947/37,020

    10,990

    31,070 / 10,191

    37 / 43 / 48

    3 / 8 (9.52)

    3R 8C 11FPI

    0.345

    1.97

    3

    B

    1 / 50 / 220~240

    250

    5

    2.514

    1

    YBNB036AAA0

    306/253/200

    12,249/11,294/8,803

    2,780

    4,950 / 1,624

    32 / 35 / 40

    3 / 8 (9.52)

    3R 8C 11FPI

    0.122

    1.18

    1

    B

    1 / 50 / 220~240

    60

    2

    0.887

    1

    YBNB046BAA0

    432/379/329

    14,876/13,898/10,884

    3,400

    6,070 / 1,991

    28 / 33 / 40

    3 / 8 (9.52)

    3R 8C 11FPI

    0.142

    1.47

    1

    B

    1 / 50 / 220~240

    70

    2

    1.036

    1

    YBNB066CAA0

    686/570/484

    21,905/19,790/15,968

    5,000

    16,300 / 5,346

    35 / 39 / 42

    3 / 8 (9.52)

    3R 8C 11FPI

    0.189

    1.70

    1

    B

    1 / 50 / 220~240

    97

    2

    1.376

    1

    YBNB086DAA0

    859/765/647

    27,637/24,839/21,018

    6,210

    20,510 / 6,727

    35 / 39 / 42

    3 / 8 (9.52)

    3R 8C 11FPI

    0.244

    1.69

    2

    B

    1 / 50 / 220~240

    148

    3

    1.775

    1

    YBNB106EAA0

    1,059/946/812

    31,049/28,490/24,566

    7,040

    26,630 / 8,735

    35 / 40 / 44

    3 / 8 (9.52)

    3R 8C 11FPI

    0.284

    1.69

    2

    B

    1 / 50 / 220~240

    178

    4

    2.071

    1

    YBNB126FAA0

    1,182/1,053/929

    37,805/34,188/28,081

    8,510

    28,840 / 9,460

    37 / 41 / 45

    3 / 8 (9.52)

    3R 8C 11FPI

    0.325

    1.80

    2

    B

    1 / 50 / 220~240

    182

    4

    2.366

    1

    Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / High Static

    Features

    32 33

    Fan Coil Unit

    YBNB036AAA0 YBNB046BAA0YBNB066CAA0 YBNB086DAA0YBNB106EAA0 YBNB126FAA0YBNB146GAA0

    Fan Coil Unit

    YBNB126HBA0 YBNB146JBA0YBNB166KBA0 YBNB186KBA0YBNB206LBA0

    3 Rows Coil

    3 - Speed Permanent Split Capacitor Motor

    Galvanized Steel

    Centrifugal Fan (Forward Curve)

    Galvanized Steel / T0.8

    PE / T5.0

    Synthetic Nylon (optional Aluminum)

    ModelPerformance

    Nominial Air Flow H / M / L CFM

    Nominial Total Capacity H / M / L Btu/h

    Water Flow Rate GPM(US)

    Water Pressure Drop kPa / ft.wg.

    Indoor Noise Level

    Noise Level L / M /H dB(A)

    Coil

    Tube Size inch(mm)

    No. of Rows, Columns & FPI

    Face Area sq.m

    Face Velocity m/s

    Motor

    Type

    No. of motor #

    Class

    Power Supply Ph/Hz/V

    Total Rating Input watt

    Fan

    Material

    Type

    No. of Fans #

    Water Content

    3 Rows Liter

    Drain Pan

    Drain Pan (Material / Thickness)

    Insulator (Meterial / Thickness)

    Filter

    Material

    No. of Filter

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    YBNB126HBA0

    1,238 / 1,052 / 941

    38,385 / 33,642 / 29,173

    8,640

    21,920 / 7,190

    44 / 48 / 52

    3 / 8 (9.52)

    3R 12C 13FPI

    0.237

    2.47

    2

    B

    1 / 50 / 220~240

    334

    2

    1.99

    1

    YBNB146JBA0

    1,441 / 1,225 / 1,095

    43,844 / 37,123 / 33,608

    9,890

    24,810 / 8,138

    46 / 49 / 54

    3 / 8 (9.52)

    3R 12C 13FPI

    0.274

    2.48

    2

    B

    1 / 50 / 220~240

    396

    2

    2.18

    1

    YBNB166KBA0

    1,594 / 1,403 / 1,265

    47,086 / 41,285 / 37,941

    10,700

    28,040 / 9,197

    47 / 52 / 56

    3 / 8 (9.52)

    3R 12C 13FPI

    0.329

    2.29

    2

    B

    1 / 50 / 220~240

    428

    2

    2.30

    1

    YBNB186KBA0

    1,803 /1,591/ 1,400

    49,815 / 43,674 / 38,556

    11,400

    34,040 / 11,165

    49 / 54 / 57

    3 / 8 (9.52)

    3R 12C 13FPI

    0.329

    2.59

    2

    B

    1 / 50 / 220~240

    517

    2

    2.30

    1

    YBNB206LBA0

    2,006 / 1,759 / 1,548

    56,639 / 49,815 / 42,991

    12,990

    38,300 / 12,562

    51 / 55 / 59

    3 / 8 (9.52)

    3R 12C 13FPI

    0.411

    2.30

    2

    B

    1 / 50 / 220~240

    710

    2

    2.85

    1

    4 Rows Coil

    3 - Speed Permanent Split Capacitor Motor

    Galvanized Steel

    Centrifugal Fan (Forward Curve)

    Galvanized Steel / T0.8

    PE / T5.0

    Synthetic Nylon (optional Aluminum)

  • Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / High Static

    Features

    ModelPerformance

    Nominial Air Flow H / M / L CFM

    Nominial Total Capacity H / M / L Btu/h

    Water Flow Rate (Middle) GPM(US)

    Water Pressure Drop (Middle) kPa / ft.wg.

    Indoor Noise Level

    Noise Level L / M /H dB(A)

    Coil

    Tube Size inch(mm)

    No. of Rows, Columns & FPI

    Face Area sq.m

    Face Velocity m/s

    Motor

    Type

    No. of motor #

    Class

    Power Supply Ph/Hz/V

    Total Rating Input (Middle) watt

    Fan

    Material

    Type

    No. of Fans #

    Water Content

    3 Rows Liter

    Drain Pan

    Drain Pan (Material / Thickness)

    Insulator (Meterial / Thickness)

    Filter

    Material

    No. of Filter

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    YBNC126HBA0

    1,348 / 1,115 / 1,051

    44,066 / 38,764 / 33,927

    8,600

    28,300 / 9,279

    50 / 53 / 59

    3/8 (9.52)

    4R 12C 13FPI

    0.237

    2.39

    2

    B

    1/50/220~240

    330

    2

    2.66

    1

    YBNC146JBA0

    1,513 / 1,338 / 1,196

    53,022 / 46,645 / 40,842

    10,340

    30,000 / 9,836

    51 / 55 / 60

    3/8 (9.52)

    4R 12C 13FPI

    0.274

    2.41

    2

    B

    1/50/220~240

    440

    2

    3.01

    1

    YBNC166KBA0

    1,702 / 1,562 / 1,296

    56,713 / 50,873 / 46,072

    11,280

    31,800 / 10,426

    49 / 55 / 59

    3/8 (9.52)

    4R 12C 13FPI

    0.274

    2.41

    2

    B

    1/50/220~240

    480

    2

    3.01

    1

    Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / High Static

    Features

    34 35

    Fan Coil Unit

    YBNC126HBA0 YBNC146JBA0YBNC166KBA0

    Fan Coil Unit

    YBNC186KBA0 YBNC206LBA0

    4 Rows Coil

    3 - Speed Permanent Split Capacitor Motor

    Galvanized Steel

    Centrifugal Fan (Forward Curve)

    Galvanized Steel / T0.8

    PE / T5.0

    Synthetic Nylon (optional Aluminum)

    ModelPerformance

    Nominial Air Flow H / M / L CFM

    Nominial Total Capacity H / M / L Btu/h

    Water Flow Rate (Middle) GPM(US)

    Water Pressure Drop (Middle) kPa / ft.wg.

    Indoor Noise Level

    Noise Level L / M /H dB(A)

    Coil

    Tube Size inch(mm)

    No. of Rows, Columns & FPI

    Face Area sq.m

    Face Velocity m/s

    Motor

    Type

    No. of motor #

    Class

    Power Supply Ph/Hz/V

    Total Rating Input (Middle) watt

    Fan

    Material

    Type

    No. of Fans #

    Water Content

    3 Rows Liter

    Drain Pan

    Drain Pan (Material / Thickness)

    Insulator (Meterial / Thickness)

    Filter

    Material

    No. of Filter

    Specification

    Note :Due to our policy of innovation some specifications may be changed without notification.

    YBNC186KBA0

    1,901 / 1,674 / 1,428

    63,412 / 54,814 / 47,326

    12,160

    36,500 / 11,967

    51 / 57 / 59

    3/8 (9.52)

    4R 12C 13FPI

    0.329

    2.59

    2

    B

    1/50/220~240

    550

    2

    3.07

    1

    YBNC206LBA0

    2,089 / 1,928 / 1,638

    73,802 / 64,129 / 54,814

    14,220

    54,100 / 17,738

    53 / 58 / 62

    3/8 (9.52)

    4R 12C 13FPI

    0.411

    2.30

    2

    B

    1/50/220~240

    650

    2

    3.80

    1

    4 Rows Coil

    3 - Speed Permanent Split Capacitor Motor

    Galvanized Steel

    Centrifugal Fan (Forward Curve)

    Galvanized Steel / T0.8

    PE / T5.0

    Synthetic Nylon (optional Aluminum)

  • MU

    L

    T

    I

    M

    D

    X

    36

    37

    LG AIR CONDITIONERS 2009

    Multi Mdx are freely interchangeable multi systems withMPS-controlled, constant speed compressors. These systems are perfectly suited for tropical conditions.

    Multi Mdx are freely interchangeable multi systems with MPS-controlled, constant speedcompressors. These systems are perfectly suited for tropical conditions.

  • MU

    L

    T

    I

    M

    D

    X

    38

    39

    LG AIR CONDITIONERS 2009 Tropical MPS Multi System InstallationNext Generation LG MPS Tropical Multi System

    are freely interchangeable multi systems with MPS-controlled, constant speedcompressors. These systems are perfectly suited for tropical conditions.

    Single Piping Type

    MPS Variable Control is LGs unique, energy-saving control technology,which is applied in both the Multi MDX series.

    * Made in Thailand

    Type Btu/h

    Wall-Mounted

    12K 18K 24K 30K 36K 48K

    ARTCOOL Mirror

    High Staic Duct

    Low Staic Duct

    4-Way Cassette

    Color variable

    *Metal

    *Blue

    *White Wood

    *Cherry

    Outdoor Unit Line-up

    Indoor Unit Line-up

    L4UC608FA2 L5UC728FA3L6UH728FA2

    L8UC1008FA3L8UC1008FA2L8UC1508FA1

    MPS Variable System- High efficiency- High reliability- Long piping & high elevation flexibility- Max.8 indoor units by simple piping- Low noise- Central control

  • MU

    L

    T

    I

    M

    D

    X

    40

    41

    LG AIR CONDITIONERS 2009 Tropical MPS Multi System InstallationNext Generation LG MPS Tropical Multi System

    Tropical MPS Multi System Solutions

    Small Office Building

    Small Office Small Shop Restaurant

    For Commercial Sites

    Resort Apartment Villa

    For Residential Sites

    Residential Building

  • MU

    L

    T

    I

    M

    D

    X

    42

    43

    LG AIR CONDITIONERS 2009 Tropical MPS Multi System InstallationNext Generation LG MPS Tropical Multi System

    Energy Saving with Tropical MPS Variable Control

    Basic Principle of Tropical MPS Variable Control Long Distance & High Elevation Piping

    Simple & Cutting Edge Control System

    Tropical Compressor Technology

    The Tropical MPS (multi power system) control two or more constant speed compressors, a hot gas bypass circuit and an linearexpansion valve (LEV). With multiple compressors operating according to increasing cooling requirements, considerable amounts ofenergy can be saved. In case of a low cooling load, only one compressor will operate. When the cooling load increases, bothcompressors will operate and balance the load.

    100%

    Conventional system (On/Off Operation)

    50% 50%

    MPS Variable Control

    Power Consumption Comparison

    MPS Variable Multi system opeates in one cycle with two compressors. Only one compressor or two compressors run together,according to the load conditions.With small load. only one compressor completes the cycle. It saves power consumption at lowoperation. This concept is explained in the picture below.

    BLDC Fan

    BLDC fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC fan motor can cut energy by35%at full velocity. AC motor is operating at full velocity only, but BLDC Motor can change velocity according to load. Energy efficiencylevels at low velocities in particular have been improved by 65%.

    The finely tuned refrigerant return ratio and special accumulatorallow piping lengths of up to 110m at a max. elevation of 45m. Therunback returns refrigerant to the compressor to maintain a safelevel of refrigerant at all times. It allows better flexibility forinstallation under difficult structural conditions.Long Distance &

    High Elevation Piping: Max. Pipe Length:110m/cycle

    - Please Refer to Page 64

    The Tropical compressor is highly reliable, even under extremeconditions (15~60C average), sandstorms and 24 houroperation. At extreme temperatures over 54C only 1 largecompressor operates to protect the smaller compressors and toprevent the indoor temperature from rising due to repeated OLPtriggering.

    INCREASED RELIABILITY- Overload Protector- High Torque Motor- Special Anti-Wear Coating- High Rigidity Crank Shaft

    28

    110

    10%

    Standard

    New Design -muffle -resonator

    33

    115

    15%

    Tropical

    Max Press.(kgf/cm2)

    Td (C)

    Under voltage

    Noise

  • MU

    L

    T

    I

    M

    D

    X

    44

    45

    LG AIR CONDITIONERS 2009 Tropical MPS Multi System InstallationNext Generation LG MPS Tropical Multi System

    Flexible Design & Simple PipingThe MPS Variable multi system uses a simple refrigerant pipe to connect one outdoor unit with multiple indoor units. It is easy to install and very economical.

    Various distributors for flexible design

    For 2 Room For 3 Room For 4 Room

    Connecting distributor without brazing

    Direct Connection Type

    Various Combination

    Piping length : 50m(A), 50m(B) Total system piping length : 100m(50+50)(Please refer to PDB for detail piping spec.)

    Installation of outdoor unit in an elevated position Installation of outdoor unit in a lower position

    Outdoor Unit(L8UC1008FA3)

    Short Tube

    Indoor Unit

    Indoor Unit45m

    Outdoor Unit(L8UC1008FA3)

    Indoor Unit

    Indoor Unit

    45m

    A

    AB

    B

    Distributor Type The Tropical MPS Multi allows simple piping for easy installation by using branch distributors.

    Total main piping length : 50m(A), 50m(B) With L5UC728FA3, L8UC1008FA3, L8UC150FA1Total branch piping length : 60m(L1+L2+L3+L4), 60m(L5+L6+L7+L8)Maximum length of single branch piping: 15m(L1, L2, L3,L4, L5, L6, L7, L8)Total system piping length: 220m = 110m(A+L1+L2+L3+L4)+110m(B+L5+L6+L7+L8)Maximum elevation from outdoor unit to indoor unit : 45m with L5UC728FA3, L8UC1008FA3, L8UC150FA1

    Installation ofoutdoor unitin lower positionInstallation of

    the outdoor unitin an upper

    position

    Outdoor Unit(L8UC1008FA3)

    Outdoor Unit(L8UC1008FA3)

    Indoor Unit

    45m

    45m

    A

    B

    B

    A

    L1

    L2

    L3

    L4

    L1

    L2

    L3

    L4

    L5

    L6

    L7

    L8

    L5

    L6

    L7

    L8

    Branch Distributor

    A,B : Main pipingL1,L2,L3,L4,L5,L6,L7,L8 : Branch pipingThe specifications above are only for two models,L8UC1008FA3/L8UC1508FA1.Please refer to the Product Data Book for other models.

    Branch Distributor

    Branch Distributor

    Branch Distributor

    Indoor Unit

    Distributor

    ForConnectable indoor UnitPower Consumption (W)Running Current Type (A)Net Dimensions (WxHxD) (mm)Net Weight (kg)Piping Connection (Outdoor Unit) Liquid / Gas (mm)Piping Connection (Indoor Unit) Liquid / Gas (mm)

    2 indoors1~210

    0.05300 x 150 x 250

    4.89.52 / 19.05

    6.35x2 / 12.7x2

    3 indoors1~310

    0.05300 x 150 x 250

    4.99.52 / 19.05

    6.35x3 / 12.7x3

    4 indoors1~410

    0.05300 x 150 x 250

    5.09.52 / 19.05

    6.35x4 / 12.7x4

    PMBD5420LUnit PMBD5430L PMBD5440L

    Notes: 1.BD unit BD unit, Indoor Unit Indoor Unit : Max. Height - 10m Set up the BD unit and Indoor Unit in 15m.2. Piping connectors must fit the piping sizes of the indoor unit to be connected.(If required, use the connector which is included with the indoor unit.)3. The BD unit should be installed inside the building.

    Easy installation with various distributors

    A variety of distributors makes installation on any site much easier.

    4 Room Type 5~6 Room Type 8 Room Type

    Use short tube in case of connecting 48K indoor unit to outdoor unit(direct piping) For detailed usage of short tube and Y-branch, please refer to PDB

    Short Tube Y Branch

  • 46 47

    L4UC608FA2 / L5UC728FA3 / L6UH728FA2

    SpecificationHPNomal Capacity Cooling kW(Min~Rating) Btu/h

    Heating kWBtu/h

    Nominal Input Cooling kW(Min~Rating) Heating kWRunning Current Cooling A

    Heating AStarting Current Cooling/Heating APower Supply , V, HzPower Supply Cable (outdoor) No.*mm2

    Power and transmission cable(outdoor to BD) No.*mm2

    Power and transmission cable(BD to indoor) No.*mm2

    Dimensions W*H*D mm(inch)Net Weight kg(Ibs)Max. Number of Connectable indoor UnitsCompressor Typeconstant speed Qty x Model(A+B) Motor Type(MPS cycle 1) Oil Type

    Oil Charge ccCompressor Typeconstant speed Qty x Model(C or C+D) Motor Type(Single or MPS cycle 2) Oil Type

    Oil Charge ccRefrigerant Charge (at 7.5m) g(oz)

    TypeControl EEV

    Short tubeHeat Exchanger (Row x Column x FPI)*No.

    Defrosting MethodFan motor Capacitor F/Vac

    DriveDischarge direction Side/TopAir Flow Rate x No.of fan CMM(cfm)

    Noise Level (H/L) Sound Pressure at 1m dB(A)+3Piping connections Liquid()(Circuit 1) mm(inch)

    Gas()(Circuit 1)Liquid()(Circuit 2)Gas()(Circuit 2)Max.total Piping mMax. OD~BD Piping mMax. total sum of BD~ID Piping mMax. OD~ID Piping mMax. OD~ID Piping m

    Max. Elevation Indoor Unit~Outdoor Unit mDifference Indoor Unit~Indoor Unit m

    MultiMDx

    MPS

    BDPiping

    Direct Piping

    Single

    L6UH728FA23.5~21.1

    12,000~72,0003.5~21.1

    12,000~72,0002.2~7.32.8~7.2

    4.9~14.74.8~14.5

    243, 380~415, 50

    5 * 5.0 (includes earth)4 * 0.75 (includes earth)4 * 0.75 (includes earth)

    806*1,607*730(31.7*63.3*28.7)190 (419)

    6Twin Rotary

    2 x QPT425YAB3 Phase Induction

    ATMOS M60/SUNISO 4GSI1,200

    Twin Rotary1 x QP425YAB

    3 Phase InductionATMOS M60/SUNISO 4GSI

    1,200Cycle 1: 4000(141)/Cycle 2:2000(70.5)

    R22MPS cycle EEV In BD unit

    Single cycle EEV in outdoor unit(079 / - / 079), (085 / - / 096)

    (2Rx17Cx18)*2+(2Rx36Cx18)*2Reverse cycle

    10/450Direct drive

    top90 (3179) x 1

    609.52 (3/8)

    19.05 (3/4)6.35 (1/4)

    15.88 (5/8)Cycle1:60 / Cycle2:45Cycle1:30 / Cycle2:30Cycle1:30 / Cycle2:15Cycle1:50 / Cycle2: -

    -3010

    L4UC608FA25.3~17.6

    18,000~60,000--

    2.9~5.7-

    5.3~10.2-

    243, 380~415, 50

    5 * 50 (includes earth)4 * 0.75 (includes earth)4 * 0.75 (includes earth)

    900*1,165*370 (35.4*45.8*14.5)104 (230)

    4Twin Rotary

    2 x QPT525YAB3 Phase Induction

    SUNISO NM561,200

    -----

    3,400 (120)R22

    MPS cycle EEV In BD unitSingle cycle EEV in outdoor unit

    -(2R x 26C x 18) * 2

    -6/370~400

    Direct driveside

    80 (2,824) x 160

    9.52 (3/8)19.05 (3/4)

    --

    603030--

    3010

    Notes: 1. Capacities are based on the following conditions:Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB

    - Outdoor Temperature 35C(95F) DB /24C(75.2F) WBHeating: - Indoor Temperature 20C(68F) DB /15C(59F) WB

    - Outdoor Temperature 7C(44.6F) DB /6C(42.8F) WBPiping Length: - Interconnecting Piping Length 7.5m

    - Level Difference of Zero.2. At least two indoor units should be connected.

    L5UC728FA33.5~21.1

    12,000~72,000--

    1.9~6.8-

    3.8~12.3-

    243, 380~415, 50

    5 * 5.0 (includes earth)4 * 0.75 (includes earth)4 * 0.75 (includes earth)

    806*1,607*730(31.7*63.3*28.7)205 (452)

    5Rotary

    2 x QPT425Y3 Phase Induction

    ATMOS M60/SUNISO 4GSI1,130

    Rotary1 x QP425Y

    3 Phase InductionATMOS M60/SUNISO 4GSI

    1,130Cycle 1: 4600(162.21)/Cycle 2:2300(81.1)

    R22MPS cycle EEV In BD unit

    Single cycle EEV in outdoor unit(079 / - / 079)

    (2Rx17Cx18)*2+(2Rx36Cx18)*2-

    10/370Direct drive

    top90 (3,179) x 1

    609.52 (3/8)

    19.05 (3/4)6.35 (1/4)

    15.88 (5/8)110506050504510

    SpecificationHPNomal Capacity Cooling kW(Min~Rating) Btu/h

    Heating kWBtu/h

    Nominal Input Cooling kW(Min~Rating) Heating kWRunning Current Cooling A

    Heating AStarting Current Cooling/Heating APower Supply , V, HzPower Supply Cable (outdoor) No.*mm2

    Power and transmission cable(outdoor to BD) No.*mm2

    Power and transmission cable(BD to indoor) No.*mm2

    Dimensions W*H*D mm(inch)Net Weight kg(Ibs)Max. Number of Connectable indoor UnitsCompressor Typeconstant speed Qty x Model(A+B) Motor Type(MPS cycle 1) Oil Type

    Oil Charge ccCompressor Typeconstant speed Qty x Model(C or C+D) Motor Type(Single or MPS cycle 2) Oil Type

    Oil Charge ccRefrigerant Charge (at 7.5m) g(oz)

    TypeControl EEV

    Short tubeHeat Exchanger (Row x Column x FPI)*No.

    Defrosting MethodFan motor Capacitor F/Vac

    DriveDischarge direction Side/TopAir Flow Rate x No.of fan CMM(cfm)

    Noise Level (H/L) Sound Pressure at 1m dB(A)+3Piping connections Liquid()(Circuit 1) mm(inch)

    Gas()(Circuit 1)Liquid()(Circuit 2)Gas()(Circuit 2)Max.total Piping mMax. OD~BD Piping mMax. total sum of BD~ID Piping mMax. OD~ID Piping mMax. total Piping mMax. OD~ID Piping m

    Max. Elevation Indoor Unit~Outdoor Unit mDifference Indoor Unit~Indoor Unit m

    Piping

    length

    spec.

    MultiMDx

    MPS

    BDPiping

    Direct Piping

    Multi M

    L8UC1508FA15.3~44.0

    18,000~150,000----

    3.5~16.3--

    6.39~29.1----

    3, 380~415, 505 * 8.4 (includes earth)

    4 * 0.75 (includes earth)4 * 0.75 (includes earth)

    1,280*1,607*730(50.4*63.3*28.7)320 (661)

    8Twin Rotary3 x QPT525Y

    3 Phase InductionSUNISO NM56

    1200Twin Rotary2 x QPT525Y

    3 Phase InductionSUNISO NM56

    1200Cycle1:7200(254)/Cycle2:4800(169)

    R222 MPS cycles EEV in BD unit

    -(2Rx14Cx18)*2+(2Rx30C x18)*1

    +(3Rx30Cx18)*1--

    10/370Direct drive

    top180 (6357)

    6012.7 (1/2)25.4 (1)

    9.52 (3/8)19.05 (3/4)

    1105060------4510

    L8UC1008FA33.5~29.3

    12,000~100,000----

    1.6~9.9--

    3.4~21.8----

    3, 380~415, 505 * 5.0 (includes earth)

    4 * 0.75 (includes earth)4 * 0.75 (includes earth)

    1,280*1,607*730(50.4*63.3*28.7)250 (551)

    8Rotary

    2 x QP425Y3 Phase Induction

    ATMOS M60/SUNISO 4GSI1130

    Rotary2 x QP425Y

    3 Phase InductionATMOS M60/SUNISO 4GSI

    11304000(141.1)

    R222 MPS cycle EEV In BD unit(079 / - / 079), (085 / - / 096)

    (2R x 14C x 18)*2 +(1R x 30C x 18)*2

    --10/370

    Direct drivetop

    90 (3179) x 260

    9.52 (3/8)19.05 (3/4)9.52 (3/8)

    19.05 (3/4)110506050----4510

    Notes: 1. Capacities are based on the following conditions:Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB

    - Outdoor Temperature 35C(95F) DB /24C(75.2F) WBHeating: - Indoor Temperature 20C(68F) DB /15C(59F) WB

    - Outdoor Temperature 7C(44.6F) DB /6C(42.8F) WBPiping Length: - Interconnecting Piping Length 7.5m

    - Level Difference of Zero.2. At least two indoor units should be connected.3. Wiring cable size must comply with the applicable local and national code.4. The specification may be subject to change without prior notice for purpose of improvement.

    L8UH1008FA23.5~29.3

    12,000~100,0003.5~29.3

    12,000~100,0001.6~9.92.3~9.0

    3.4~21.84.2~16.0

    --3, 380~415, 50

    5 * 5.0 (includes earth)4 * 0.75 (includes earth)4 * 0.75 (includes earth)

    1,280*1,607*730(50.4*63.3*28.7)250 (551)

    8Rotary

    2 x QP425Y3 Phase Induction

    ATMOS M60/SUNISO 4GSI700

    Rotary2 x QP425Y

    3 Phase InductionATMOS M60/SUNISO 4GSI

    7004000(141.1)

    R222 MPS cycles EEV in BD unit(079 / - / 079), (085 / - / 096)

    (2R x 14C x 18)*2 + (1R x 30C x 18)*2

    Reverse cycle10/370

    Direct drivetop

    90 (3179) x 260

    9.52 (3/8)19.05 (3/4)9.52 (3/8)

    19.05 (3/4)60303050----3010

    L8UC1008FA3 / L8UH1008FA2 / L8UC1508FA1

  • 48 49

    Combination of Indoor and Outdoor Unit

    Model TypeCapacity

    Wall Mounted General

    Mirror

    4 Way

    Hight Static

    Low Static

    ARTCOOL

    Ceiling Cassette

    Ceiling ConcealedDuct

    Index

    1218241218241218243036481824303648121824

    Btu/h

    12,00018,00024,00012,00018,50024,00012,00018,00024,00030,00036,00048,00018,00024,00030,00036,00048,00012,00018,00024,000

    kW

    3.525.287.033.525.427.033.2

    5.287.038.79

    10.5514.075.287.038.79

    10.5514.073.525.287.03

    up to 4

    ---------

    up to 5

    up to 8

    up to 6

    up to 8

    ------

    Indoor Units

    Number of Connectible Indoor Units

    L4UC608FA2 L5UC728FA3 L6UH728FA2 L8UC1008FA3L8UH1008FA2

    L8UC1508FA1

    Outdoor Units

    Notes:1. The total capacity index of indoor units is the of capacity index of eachunits and shoul be within the maximum capacity index of the outdoor unit.

    Combination Table L4UC608FA2L5UC728FA3

    Current (A)Input (W)

    Operation

    Unit

    1 unit

    2 units

    3 units

    4 units

    Unit-A

    180002400030000360004800018000180001800018000160002400024000200003000028000180001800016000150002000015000

    Unit-B

    -----

    18000240003000036000440003000036000400003000034000180001800016000150002000015000

    Unit-C

    ---------------

    180002300028000300002000015000

    Unit-D

    --------------------

    15000

    Total

    180002400030000360004800036000420004800054000600005400060000600006000062000540005900060000600006000060000

    285028503000560060505600560060505800630063006300630063006300580057006300630058005900

    5.35.35.59.09.29.09.29.69.69.89.69.610.29.69.610.210.29.69.610.210.6

    Combination of Indoor unit(k Btu/h)Capacity (Btu/h)

    Cooling

    Notes:1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB2. The total capacity of indoor unit of "Circuit 1" is up to 36000 Btu/h (10.6kW). The total capacity of indoor unit of "Circuit 2" is up to 24000 Btu/h (7.1kW).3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]

    Unit-A

    182430364818181818182424243030181818182418

    Unit-B

    -----

    18243036483036483036181818182418

    Unit-C

    ---------------

    182430362418

    Unit-D

    --------------------

    18

    Total

    182430364836424854665460726066546066727272

    Current (A)Input (W)

    Operation

    UnitCircuit

    1

    2

    1 unit

    1 unit

    2 units

    3 units

    4 units

    Unit-A

    480001200018000180001800016000220002400012000120001200011110120001111016670120001100024000

    Unit-B

    -36000180002400030000340002800024000120001200012000111101800016670166701200011000

    -

    Unit-C

    --------

    120001800024000277801800022220166701200011000

    -

    Unit-D

    ---------------

    1200017000

    -

    Total

    480004800036000420004800050000500004800036000420004800050000480005000050000480005000024000

    460042504250425046004600460046004100410042504250425042504250425042502450

    8.28.08.08.08.28.28.28.27.87.88.08.08.08.08.08.08.04.5

    Combination of Indoor units (k Btu/h)Capacity (Btu/h)

    Cooling

    Notes:1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB2. The maximum capacity available for this model is 54k Btu/hr (15.8kW).3. The capacity is based on standard length of interconnecting refrigerant line.4. The number of indoor units that can be installed is from 2 to 4. Below 2 indoor units, installation is not possible.5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of

    indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

    Unit-A

    481218181818242412121212121218121224

    Unit-B

    -36182430363024121212121818181212-

    Unit-C

    --------

    121824301824181212-

    Unit-D

    ---------------

    1218-

    Total

    484836424854544836424854485454485424

    L5UC728FA3

    L4UC608FA2

  • 50 51

    Combination TableCombination Table L8UC1008FA3, L8UH1008FA2Combination TableCombination Table L6UH728FA2

    Notes:1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB2. Heating Capacity is based on : indoor temp.20C(60F) DB; outdoor temp. 7C(44.6F) DB, 6C(42.8F) WB3. The maximum capacity available is 54kBtu/h (15.8kW) per circuit.4. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of

    indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

    Current (A)Input (W)

    Operation

    UnitCircuit

    1

    or

    2

    1 unit

    2 units

    3 units

    4 units

    Unit-A

    48000 / 4800012000 / 1200018000 / 1800018000 / 1800018000 / 1800016000 / 1600022000 / 2200024000 / 2400012000 / 1200012000 / 1200012000 / 1200011110 / 1111012000 / 1200011110 / 1111016670 / 1667012000 / 1200011000 / 11000

    Unit-B

    - / -36000 / 3600018000 / 1800024000 / 2400030000 / 3000034000 / 3400028000 / 2800024000 / 2400012000 / 1200012000 / 1200012000 / 1200011110 / 1111018000 / 1800016670 / 1667016670 / 1667012000 / 1200011000 / 11000

    Unit-C

    - / -- / -- / -- / -- / -- / -- / -- / -

    12000 / 1200018000 / 1800024000 / 2400027780 / 2778018000 / 1800022220 / 2222016670 / 1667012000 / 1200011000 / 11000

    Unit-D

    - / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -

    12000 / 1200017000 / 17000

    Total

    48000 / 4800048000 / 4800036000 / 3600042000 / 4200048000 / 4800050000 / 5000050000 / 5000048000 / 4800036000 / 3600042000 / 4200048000 / 4800050000 / 5000048000 / 4800050000 / 5000050000 / 5000048000 / 4800050000 / 50000

    5300 / 46005300 / 46003800 / 31004500 / 38005300 / 46005400 / 47005400 / 47005300 / 46003800 / 31004500 / 38005300 / 46005400 / 47005300 / 46005400 / 47005400 / 47005300 / 46005400 / 4700

    8.5 / 7.38.5 / 7.36.0 / 4.97.2 / 6.08.5 / 7.38.6 / 7.58.6 / 7.58.5 / 7.36.0 / 4.97.2 / 6.08.5 / 7.38.6 / 7.58.5 / 7.38.6 / 7.58.6 / 7.58.5 / 7.38.6 / 7.5

    Combination of Indoor units (k Btu/h)Capacity (Btu/h)

    Cooling / Heating

    Unit-A

    4812181818182424121212121212181212

    Unit-B

    -36182430363024121212121818181212

    Unit-C

    --------

    121824301824181212

    Unit-D

    ---------------

    1218

    Total

    4848364248545448364248544854544854

    L8UC1008FA3, L8UH1008FA2

    Current (A)Input (W)

    Operation

    UnitCircuit

    1

    2

    1 unit

    1 unit2 unit

    2 units

    3 units

    4 units

    Unit-A

    48000 / 4800012000 / 1200018000 / 1800018000 / 1800018000 / 1800016000 / 1600022000 / 2200024000 / 2400012000 / 1200012000 / 1200012000 / 1200011110 / 1111012000 / 1200011110 / 1111016670 / 1667012000 / 1200011000 / 1100024000 / 2400012000 / 12000

    Unit-B

    - / -36000 / 3600018000 / 1800024000 / 2400030000 / 3000034000 / 3400028000 / 2800024000 / 2400012000 / 1200012000 / 1200012000 / 1200011110 / 1111018000 / 1800016670 / 1667016670 / 1667012000 / 1200011000 / 11000

    - / -12000 / 12000

    Unit-C

    - / -- / -- / -- / -- / -- / -- / -- / -

    12000 / 1200018000 / 1800024000 / 2400027780 / 2778018000 / 1800022220 / 2222016670 / 1667012000 / 1200011000 / 11000

    - / -- / -

    Unit-D

    - / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -- / -

    12000 / 1200017000 / 17000

    - / -- / -

    Total

    48000 / 4800048000 / 4800036000 / 3600042000 / 4200048000 / 4800050000 / 5000050000 / 5000048000 / 4800036000 / 3600042000 / 4200048000 / 4800050000 / 5000048000 / 4800050000 / 5000050010 / 5001048000 / 4800050000 / 5000024000 / 2400024000 / 24000

    4720 / 43304730 / 46404580 / 45604700 / 45604720 / 46304790 / 46804790 / 46804720 / 46304580 / 45604680 / 45604720 / 46404790 / 46704720 / 46404790 / 46704790 / 46704720 / 46404790 / 46702550 / 25702450 / 2570

    9.4 / 9.29.4 / 9.39.2 / 9.09.2 / 9.09.4 / 9.39.6 / 9.59.6 / 9.59.4 / 9.39.2 / 9.09.3 / 9.09.4 / 9.39.6 / 9.49.4 / 9.39.6 / 9.39.6 / 9.49.4 / 9.39.6 / 9.44.9 / 4.94.9 / 4.9

    Combination of Indoor unit(k Btu/h)Capacity (Btu/h)

    Cooling / Heating

    Notes:1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB2. The maximum capacity available for Circuit 1 is 54kBtu/h (15.8kW). The total capacity of indoor unit of "Circuit 2" is up to 24 kBtu/h (7.1kW).3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of

    indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

    Unit-A

    48121818181824241212121212121812122412

    Unit-B

    -36182430363024121212121818181212-

    12

    Unit-C

    --------

    121824301824181212--

    Unit-D

    ---------------

    1218--

    Total

    48483642485454483642485448545448542424

    L6UH728FA2

  • 52 53

    Combination Table L8UC1508FA1 Combination Table L8UC1508FA1

    Cooling : There are two different cycles.

    Cycle 1 : 90 kBtu/h

    Current (A)Input (W)

    Operation

    UnitCircuit

    2 units

    3 units

    4 units

    Unit-C

    18243036482430364830364824303648303636303618181818242424242424

    Unit-D

    18243036243036243024

    Total

    36424854664854607260667872849654606672846672789078849672788496849096909672788490849096909696

    Unit-A

    19000190001900019000150002500025000240002500030000270003200038000360004500018000180001600019000180001600019000190001800019000180001600025000250002400022000240002400022000300002800019000190001800018000180001800016500180001650022500

    338059806220646069406220646567009000670069409370900097001050064606700690090009730694090009370101009370970010400900093009700104009700101001040010100104009000930097001010097001010010400101001040010400

    6.010.711.011.412.211.111.411.816.111.812.216.716.117.318.511.411.812.216.117.312.216.116.717.916.717.318.416.116.717.318.517.317.918.517.918.516.116.717.317.917.317.918.517.918.518.5

    Unit-B

    19000250003100037000450002500031000360004900030000330005000038000480004500018000180001600019000180002200025000250002400031000300002800025000250002400022000300003000034000300002800019000190001800018000180001800016500240002250022500

    Unit-C

    18000240002800037000480002200031000370004800031000360004600025000310003600046000300003600034000300003400019000190001800018000240002400022500240002250022500

    Unit-D

    19000250003000036000240003000034500240002850022500

    Total

    38000440005000056000600005000056000600007400060000600008200076000840009000054000600006000075000840006000075000810009000081000840009000075000810008400090000840009000090000900009000076000820008400090000840009000090000900009000090000

    Combination of Indoor units (k Btu/h)Capacity (Btu/h)

    Cooling

    Unit-B

    18243036482430364830364836484818181818182424242430303024242424303036303018181818181818242424

    Unit-A

    18181818182424242430303036364818181818181818181818181824242424242424303018181818181818181824

    Notes:1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB2. The maximum capacity available for Circuit 1 is 96kBtu/h (28.1kW). The maximum capacity available for Circuit 2 is 72kBtu/h (21.1kW).3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of

    indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

    1

    Cycle 2 : 60 kBtu/h

    Current (A)Input (W)

    Operation

    UnitCircuit

    2 units

    3 units

    4 units

    Unit-C

    1824303624302418

    Unit-D

    18

    Total

    36424854664854607260665460667266727272

    Unit-A

    19000190001900019000150002500025000240001800030000270001800018000160001400016000140002000015000

    3500598061506350675061506350656069006600675063506600675069406750694069406940

    6.010.711.011.311.911.011.311.612.211.611.911.311.611.912.211.912.212.212.2

    Unit-B

    19000250003100037000450002500031000360004200030000330001800018000160001400022000200002000015000

    Unit-C

    1800024000280003200022000260002000015000

    Unit-D

    15000

    Total

    38000440005000056000600005000056000600006000060000600005400060000600006000060000600006000060000

    Combination of Indoor units (k Btu/h)Capacity (Btu/h)

    Cooling

    Unit-B

    18243036482430364830361818181824242418

    Unit-A

    18181818182424242430301818181818182418

    Notes:1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB2. The maximum capacity available for Circuit 1 is 96kBtu/h (28.1kW). The maximum capacity available for Circuit 2 is 72kBtu/h (21.1kW).3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of

    indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.

    2

  • 54 55

    Wall Mounted Split Type

    The air vanes will beadjusted according tothe mode ofoperation. In heatingmode air will bedistributed at a lowerangle due to hot airrising.

    Optimized Cooling & Heating Air Flow

    LG Electronics air conditioner improves the difference betweenhigh and low indoor temperatures . It allows you to reach yourdesired temperatures even faster

    Even & Fast Air flow

    To provide a comfortable, pleasant and well balancedenvironment, LG air conditioners utilize a streamlined air fanand a unique design which create smooth air flow from the air conditionerso that it operates under the lowest noise level. The cross flow fan, stabilizer, and rear guide which are the causes of noise, have been redesigned by hydraulic engineering. The number of revolutions have been decreased or increased whilethe amount of friction has been decreased

    providing the most quiet air conditioners in the world.

    Innovative quiet operation

    New chaos swing

    With the Jet Cool function astrong and cool air stream isblown at high speed for 30minutes, until the roomtemperature reaches 18 C

    JET Cool

    Dehumidification mode reduces uncomfortable humidity fromthe room without over cooling.

    Healthy Dehumidification

    LG AIR CONDITIONERS 2009

    - Triple deodorizing filter is for absorbing VOC ingredient,common odor

    - Deodorizing efficiency:10% up compared to norma deodorizatior filter

    Triple Deodorizing Filter

    The Nano PLASMA Air Purifying System, developed uniquely byLG, not only removes microscopic contaminants and dust, butalso eliminates house mites, pollen and pet fur to preventallergic diseases like asthma. It also eliminates bad odors byneutralizing odor particles. With a reusable filter that cansimply be cleaned with a vacuum cleaner, you can enjoy clean,fresh air without the cost of regular filter changes.

    Air Purifying System

    Model

    Power Supply / V / Hz

    Cooling Capacity kW

    Btu/h

    Heating Capacity kW

    Btu/h

    Current Nominal running current A

    Fan Motor Type

    Fan Type

    Motor Output x Number of Unit

    Air Flow Rate (H) cmm

    cfm

    Capacitor F/Vac

    Drive

    Coil Row x column x FPI mm

    Dimensions (WxHxD) Body mm(inch)

    Weight Body kg(lbs)

    Air Filter

    Sound Level (H/M/L) dB(A)3

    Piping Connections Liquid mm(inch)

    Gas mm(inch)

    Drain(OD/ID) mm

    Dehumidification Rate l/h

    Safety devices

    Temperature Sensor

    Referigerant

    Referigerant Control

    Connectable outdoor unit

    Power and transmission interunit cable No.* mm2

    (including earth)

    LMN(C)H126D4*0

    1 / 220~240 / 50

    3.52

    12,000

    3.52

    12,000

    0.22

    Induction

    Cross Flow Fan

    40 x 1

    10

    353

    9.0 / 400

    Direct Drive

    2R x 15C x 20

    840 x 270 x 153(33.1 x 10.6 x 6.0)

    7 (15.4)

    Long Life Filter

    40 / 35 / 30

    6.35 (1/4)

    12.7 (1/2)

    21.5 / 16.0

    1.5

    R22

    EEV

    Multi M DX

    4 x 0.75 (including earth)

    LMN(C)H186D5*0

    1 / 220~240 / 50

    5.28

    18,000

    5.28

    18,000

    0.28

    Induction

    Cross Flow Fan

    62 x 1

    13

    459

    1.5 / 370

    Direct Drive

    2R x 15C x 20

    1,090 x 300 x 180(42.9 x 11.8 x 7.1)

    13 (28.7)

    Long Life Filter

    40 / 37 / 33

    6.35 (1/4)

    12.7 (1/2)

    21.5 / 16.0

    2.0

    R22

    EEV

    Multi M DX

    4 x 0.75 (including earth)

    LMN(C)H246D5*0

    1 / 220~240 / 50

    7.03

    24,000

    7.03

    24,000

    0.35

    Induction

    Cross Flow Fan

    70 x 1

    14

    494

    2.0 / 370

    Direct Drive

    2R x 15C x 20

    1,090 x 300 x 180(42.9 x 11.8 x 7.1)

    13 (28.7)

    Long Life Filter

    45 / 42 / 37

    6.35 (1/4)

    15.88 (5/8)

    21.5 / 16.0

    3.1

    R22

    EEV

    Multi M DX

    4 x 0.75 (including earth)

    Notes:-1. Capacities are based on the following conditions:

    Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB- Outdoor Temperature 35C(95F) DB /24C(75.2F) WB- Interconnecting Piping Length 7.5m- Level Difference of Zero.

    Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB- Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB- Interconnecting Piping Length 7.5 m- Level Difference of Zero.

    2. Capacities are Net Capacities.3. Due to our policy of innovation some specifications may be changed without notification.4. *: See the page "Combination Table"

    Cooling mode Heating mode

    Fuse, Thermal Protector for Fan Motor

    Thermistor

    Odor Free! Dust Free! Allergy Free!

    The most comfortable airflow for the human body canbe found in nature. After countless analysis, LG hasapplied the scientific chaos theory to its air conditioningrange, which effectively produces a