lg pi485 gateway -...

15
LG PI485 GATEWAY INSTALLATION MANUAL LG Models: PHNFP14A0 PSNFP14A0 IMPORTANT • Please read this installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this installation manual for future reference after reading it thoroughly.

Upload: others

Post on 12-Oct-2019

1 views

Category:

Documents


0 download

TRANSCRIPT

LGPI485 GATEWAYINSTALLATION MANUAL

LG

Models: PHNFP14A0PSNFP14A0

IMPORTANT

• Please read this installation manual completely before installing the product.

• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

• Please retain this installation manual for future reference after reading it thoroughly.

2 485 Gateway(M)

Central Control Unit Use & Care Manual

TABLE OF CONTENTS� Part Installation & Operation precution .....................3~4

� Part Description ...........................................................5

� Installation Guide ..........................................................7

� Installation Steps .................................................................................7

� DIP Switch Configuration.....................................................................8

� Simple Central Controller - Connection Diagram ..............................10

� Deluxe Central Controller - Connection Diagram ..............................12

� Examples For Product Installation.....................................................13

� Accessory Parts .........................................................14

Safety Precautions

Installation Manual 3

Don't touch with thehands while the power ison

• There is risk of fire or electricshock.

Use standardparts(connector).

• Do not disassemble or repairthe product. There is risk of fireor electric shock.

For electrical work, contactthe dealer, seller, a qualifiedelectrician, or an AuthorizedService Center.

• Do not disassemble or repairthe product. There is risk of fireor electric shock.

� Installation

ON

L1 2 3 4

KSDO4H

ON

L1

2 3

4

KSD

O4H

ON

L1

2 3

4

KSD

O4H

Safety PrecautionsTo prevent injury to the user or other people and property damage, the following instructionsmust be followed.� Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is

classified by the following indications.

� Meanings of symbols used in this manual are as shown below.

WARNING

CAUTION

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage.

Be sure not to do.

Be sure to follow the instruction.

WARNING

Safety Precautions

4 485 Gateway(M)

When the product is soaked (flooded orsubmerged), contact an Authorized ServiceCenter.• There is risk of fire or electric shock.

Be cautious that water could not enter theproduct.

• There is risk of fire, electric shock, or productdamage.

ON

L1

2 3

4

KSD

O4H

ON

L1

2 3

4

KSD

O4H

� Operation

Use the correctly ratedbreaker or fuse.

• There is risk of fire or electricshock.

Do not install, remove, or re-install the unit by yourself(customer).

• There is risk of fire, electricshock, explosion, or injury.

For installation, alwayscontact the dealer or anAuthorized Service Center.

• There is risk of fire, electric

shock, explosion, or injury.

ON

L1

2 3

4

KSD

O4H

ON

L1

2 3

4

KSD

O4H

ON

L1

2 3

4

KSD

O4H

Part Description

Installation Manual 5

Part DescriptionPHNFP14A0

PI485 GATEWAY(C)

CN_OUT: Indoor Unit Connector

BUS_B: RS-485 (-) Terminal

BUS_A: RS-485 (+) Terminal

LED01G,02G,03G: Communication Status LED

LED1: RS-485 Communication Status LED

Reset Switch: PI485(C) Reset

DIP Switch: Product Select (Refer Page 8)

S1

BR1

TANS01Y

ZNR01Y

U02YU04YU03Y

SWITCH

LED1

LED0

1GLE

D02G

LED0

3G

OSC0

1BL0

2DL0

1D C01A

IC01

A

CN_COMM

C03Y

C04Y

ON

L1 2 3 4

1

2

3

4

5

6

7

1

234

567

6 485 Gateway(M)

Part Description

PSNFP14A0

PI485 GATEWAY(R)

CN_OUT: Indoor Unit Connector

BUS_A: RS-485 (+) Terminal

BUS_B: RS-485 (-) Terminal

LED01G,02G,03G: Communication Status LED

LED1: RS-485 Communication Status LED

Reset Switch: PI485(C) Reset

DIP Switch: Product Select (Refer Page 9)

ONL1 2 3 4

1

2

3

5

7

6

4

1

234

567

Installation Manual 7

Installation Guide

Installation Steps (PHNFP14A0/PSNFP14A0)

1. Select DIP Switch Configuration(Refer page 8 or 9)

2. Connect The RS-485 BUS_A(+), BUS_B(-) with Other Network Products (ex,Simple Central Controller , CNU.....)

3. Connect CN_OUT with Outdoor Unit by the cable (provided)

4. Check the Communication Status LED

- LED01G(Red): Ok operation-LED blinks for 5times and is OFF. This process is repeated after every 3 minutes• NG operation : Check The Indoor unit address & Wiring Connections

- LED02G(Yellow) ,LED03G(Orange): Ok operation-LED's blinks continuously• NG operation : Check The DIP Switch setting & Wiring Connections

5. Check the RS-485 Communication Status LED:

� Ok operation

(1) LED's blinks 2 Times in every 10~30 seconds (In case Connected CNU)

(2) LED's blinks continuously (In case Connected Simple Central Controller)

� NG operation : Check The Wiring Connections

6. Finally if all the above steps are OK then , Tie the cables by Tie Wraps & Clamp

Installation Guide

1

7

4

5

2 3

8 485 Gateway(M)

Installation Guide

ON KSDO 4HS1

BR1

TANS01Y

ZNR01Y

U02YU04YU03Y

SWITCH

LED1

LED0

1GLE

D02G

LED0

3G

OSC0

1BL0

2DL0

1D C01A

IC01

A

CN_COMM

C03Y

C04Y

ON

L1 2 3 4

L1 2 3 4

Select AirConditioner Type

Select NetworkType

ON KSDO4H

ON KSDO4H

L1 2 3 4

L1 2 3 4

DIP Switch Configuration

3 ON+ALL OFF: Using LGAP CAC/RAC/SRAC/PAC ProductsConfiguration Methods

3, 4 ON+ALL OFF: LGAP CAC/RAC/SRAC/PAC Products + CentralController (ALL type)-Using LGAP

Using LGAP CAC/RAC/SRAC/PAC Products Configuration Methods

• PHNFP14A0

CAUTION: Wrong Products Configuration can lead to malfunctioning

Installation Guide

Installation Manual 9

ON KSDO 4H

L1 2 3 4

Select AirConditioner Type

Select NetworkType

ONL1 2 3 4

ON KSDO4H

ON KSDO4H

L1 2 3 4

L1 2 3 4

3 ON+ALL OFF: LGAP CAC/RAC/SRAC/PAC Products + CentralController (ALL type)-Without LGAP

3, 4 ON+ALL OFF: LGAP CAC/RAC/SRAC/PAC Products + CentralController (ALL type)-Using LGAP

Using LGAP CAC/RAC/SRAC/PAC Products Configuration Methods

• PSNFP14A0

CAUTION: Wrong Products Configuration can lead to malfunctioning

10 485 Gateway(M)

Installation Guide

S1

BR1

TANS01Y

ZNR01Y

U02YU04YU03Y

SWITCH

LED1

LED0

1GLE

D02G

LED0

3G

OSC0

1BL0

2DL0

1D C01A

IC01

A

CN_COMM

C03Y

C04Y

ON

L1 2 3 4

Indoor Main PCB

Simple Central Controller

DC 10V

VCC

Bus BCN_OUTCN_COMM

Bus A

GNDDC

Indoor Main PCB

CN_CC

CN_CC

PI485 GATEWAYSimple Central Controller

CENTRALCONTROLUNIT

Simple Central Controller - Connection Diagram

CAUTION: After Product Installation Tie the cables with the clamps & Tie-Wraps provided.

• PHNFP14A0

Installation Guide

Installation Manual 11

Indoor Main PCB

Simple Central Controller

DC 10V

VCC

Bus B

Bus AGND

DC

Indoor Main PCB

CN_CC

CN_CC

PI485 GATEWAY Simple Central Controller

CENTRALCONTROLUNIT

ONL1 2 3 4

ONL1 2 3 4

CAUTION: After Product Installation Tie the cables with the clamps & Tie-Wraps provided.

• PSNFP14A0

12 485 Gateway(M)

Installation Guide

S1

BR1

TANS01Y

ZNR01Y

U02YU04YU03Y

SWITCH

LED1

LED0

1GLE

D02G

LED0

3G

OSC0

1BL0

2DL0

1D C01A

IC01

A

CN_COMM

C03Y

C04Y

ON

L1 2 3 4

Indoor Main PCB

Bus B

Bus A

Bus B

Bus A

Bus B

Bus A

PI485 GATEWAYPCB

PI485 GATEWAYPCB

CN_CC

Indoor Main PCB

CN_CC

CNUPCB

Bus B

Bus A

CNUPCB

ONL1 2 3 4

Deluxe Central Controller - Connection Diagram

CAUTION: After Product Installation Tie the cables with the clamps & Tie-Wraps provided.

• PHNFP14A0

• PSNFP14A0

Installation Guide

Installation Manual 13

Examples For Product Installation

CAUTION: It can be Different location of installation in order to Each Product structure

(1) The Installation for 4Way CassetteProduct

� Check Screw boss for PCB in 4wayCassette Product Then fix It

(2) The Installation for DUCT Product� Using PCB Holder provided

(3) The Installation for Cassette ProductCover� Check Screw boss for PCB in 4way

Cassette Product Then fix It

14 485 Gateway(M)

Acceassory Parts

Acceassory Parts

S1

BR1

TANS01Y

ZNR01Y

U02YU04YU03Y

SWITCH

LED1

LED0

1GLE

D02G

LED0

3G

OSC0

1BL0

2DL0

1D C01A

IC01

A

CN_COMM

C03Y

C04Y

ON

L1 2 3 4

PCB :6871A20484B Holder for DUCT :3110A 20056A WIRE ASSY 1(for RAC/SRAC/CAC)

Screw 4 EA Installation Manual WIRE ASSY(for Others)

ONL1 2 3 4

PCB :6871A20484C

WIRE ASSY 1(for RAC/SRAC/CAC) WIRE ASSY(for Others)

Screw 4 EA Installation Manual

* Others : Tie Wrap (3 EA) - Cable TieClamp (1 EA)

• PSNFP14A0

• PHNFP14A0

P/No.: 3828A20365QAfter reading this manual, keep it in a place easily accessible to the user for future reference.

Printed in Korea