lgh hp presentation
DESCRIPTION
TRANSCRIPT
Living Green HomesLiving Green HomesPRESENTSPRESENTS
www.www.LivingGreenOn319.LivingGreenOn319.comcom
A Safe, Healthy and A Safe, Healthy and
Energy Efficient HomeEnergy Efficient Home
Presented by:Presented by:
Jason ScheurerJason Scheurer
Environmental Building ScientistEnvironmental Building Scientist
Living Green HomesLiving Green HomesA Green Consulting CompanyA Green Consulting Company
Building Performance Institute (BPI) CertifiedBuilding Performance Institute (BPI) Certified
GreenPoint Rater for New Homes GreenPoint Rater for New Homes
& Existing Homes& Existing Homes
Home Performance with Energy Star Contractor Home Performance with Energy Star Contractor
(Home Star)(Home Star)
LGH Specializes in:LGH Specializes in:
Building Science Education and Energy Efficient RetroBuilding Science Education and Energy Efficient Retro--fitsfits
Whole House Approach to Remodeling of Existing HomesWhole House Approach to Remodeling of Existing Homes
New Construction and Development of SFRNew Construction and Development of SFR
Living Green HomesLiving Green Homes
Jason ScheurerJason Scheurer
Licensed General Contractor Since 1995Licensed General Contractor Since 1995
Green Consultant for Indoor Air Quality, Green Consultant for Indoor Air Quality, Energy Efficiency, Building Envelope and Energy Efficiency, Building Envelope and Green ProductsGreen Products
GreenPoint Rater (GPR) with Build It GreenGreenPoint Rater (GPR) with Build It Green
Living Green HomesLiving Green Homes
Penny ScheurerPenny Scheurer
Licensed General Contractor Since 1995Licensed General Contractor Since 1995
Green Consultant for Indoor Air Quality, Green Consultant for Indoor Air Quality,
Energy Efficiency, Interior Design and Energy Efficiency, Interior Design and
Green ProductsGreen Products
Existing HomesExisting Homes
Energy Efficient RetroEnergy Efficient Retro--fitsfits
Air InfiltrationAir Infiltration
HVAC SystemsHVAC Systems
Insulation LevelsInsulation Levels
Indoor Air Quality Products Indoor Air Quality Products
(Finish Materials)(Finish Materials)
AIR INFILTRATION PROBLEMSAIR INFILTRATION PROBLEMS
Electrical holes in Electrical holes in
wood framing wood framing
members.members.
Ceiling fan with trim Ceiling fan with trim
cover plate falling off.cover plate falling off.
AIR INFILTRATION PROBLEMSAIR INFILTRATION PROBLEMS
Pipe penetration from Pipe penetration from
Garage to inside of Garage to inside of
house.house.
Laundry wall with Laundry wall with
drywall damage from drywall damage from
a water leak.a water leak.
HVAC SYSTEMS THAT FAILHVAC SYSTEMS THAT FAIL
Ducts disconnected at Ducts disconnected at main air handler.main air handler.
4 out of 5 duct systems 4 out of 5 duct systems leak an average of 35%leak an average of 35%--50% of conditioned air.50% of conditioned air.
Disconnected duct Disconnected duct bringing in hot/cold air bringing in hot/cold air from attic.from attic.
HVAC SYSTEMS THAT FAILHVAC SYSTEMS THAT FAIL
Disconnected duct Disconnected duct
coupling that has coupling that has
Asbestos wrap around it.Asbestos wrap around it.
Indoor Air Quality is Indoor Air Quality is
terrible in our existing terrible in our existing
homes.homes.
Looks like rats are eating Looks like rats are eating
their Asbestos Dinner.their Asbestos Dinner.
INSULATION DEFECTSINSULATION DEFECTS
Sloppy and missing Sloppy and missing
attic insulation.attic insulation.
Completely missing Completely missing
insulation and rat insulation and rat
traps.traps.
INSULATION DEFECTSINSULATION DEFECTS
Insulation that has Insulation that has
been just thrown into been just thrown into
the attic, stepped on the attic, stepped on
and misplaced.and misplaced.
Interstitial wall cavity Interstitial wall cavity
connecting the floors connecting the floors
and attic together.and attic together.
INDOOR AIR QUALITY INDOOR AIR QUALITY
PROBLEMSPROBLEMS
Rat droppings at the Rat droppings at the
leaky HVAC handler to leaky HVAC handler to
duct work. This must be a duct work. This must be a
warm/cold spot.warm/cold spot.
Whole house fan blowing Whole house fan blowing
air into the attic. air into the attic.
WhatWhat’’s wrong with this ?s wrong with this ?
INDOOR AIR QUALITY INDOOR AIR QUALITY
PROBLEMSPROBLEMS
Waste drain vent Waste drain vent
disconnected with disconnected with
Methane gases Methane gases
seeping into the attic.seeping into the attic.
How clean is your How clean is your
HVAC return filter ?HVAC return filter ?
Effects of Air LeakageEffects of Air Leakage
These are typical pictures of These are typical pictures of what we see when we test the what we see when we test the average home.average home.
Cold air infiltrates from below.Cold air infiltrates from below.
Hot air escapes from up Hot air escapes from up above.above.
This creates a stack effect, This creates a stack effect, which makes homes drafty, which makes homes drafty, hot/cold, which in turn, costs hot/cold, which in turn, costs more money to operate more money to operate efficiently. efficiently.
Not to mention the Asthma and Not to mention the Asthma and Allergy problems we see on a Allergy problems we see on a daily basis.daily basis.
AIR INFILTRATION SOLUTIONSAIR INFILTRATION SOLUTIONS
Seal and caulk all blocks, brackets, and Seal and caulk all blocks, brackets, and
nail penetrations coming into the home. nail penetrations coming into the home.
Also install moisture barrier at all Also install moisture barrier at all
openings.openings.
AIR INFILTRATION SOLUTIONSAIR INFILTRATION SOLUTIONS
Rim joists from first story to second story and Rim joists from first story to second story and electrical penetrations all need to be sealed electrical penetrations all need to be sealed and/or insulated properly. This will help prevent and/or insulated properly. This will help prevent air from traveling inside the walls and to other air from traveling inside the walls and to other floors.floors.
AIR INFILTRATION SOLUTIONSAIR INFILTRATION SOLUTIONS
Stairways have major air infiltration problems to Stairways have major air infiltration problems to
each floor. Sealing them off helps stop any dirt, each floor. Sealing them off helps stop any dirt,
dust, and possible mold spores from traveling dust, and possible mold spores from traveling
from basement to floors and walls.from basement to floors and walls.
AIR INFILTRATION SOLUTIONSAIR INFILTRATION SOLUTIONS
All electrical boxes (especially exterior) should All electrical boxes (especially exterior) should be sealed tightly, this stops conditioned air from be sealed tightly, this stops conditioned air from moving around between basement, floors and moving around between basement, floors and walls.walls.
HVAC SYSTEMS THAT WORKHVAC SYSTEMS THAT WORK
Properly installed Properly installed
Liquid Mastic, Metal Liquid Mastic, Metal
Tape, Zip Ties, and Tape, Zip Ties, and
Insulation Wrap.Insulation Wrap.
these are great ways these are great ways
to seal duct vents to seal duct vents
from leaking from leaking
conditioned air into conditioned air into
the basements, walls the basements, walls
and attic areas.and attic areas.
HVAC SYSTEMS THAT WORKHVAC SYSTEMS THAT WORK
Properly sealed ducts Properly sealed ducts
at the Plenum, will at the Plenum, will
help stop air leakage help stop air leakage
and make your HVAC and make your HVAC
System perform at itSystem perform at it’’s s
highest levels.highest levels.
Insulation at Plenum Insulation at Plenum
will distribute the air will distribute the air
where it needs to go. where it needs to go.
PROPERLY INSTALLED PROPERLY INSTALLED
INSULATIONINSULATION
BlownBlown--in Cellulose in Cellulose
(Recycled Newspaper) (Recycled Newspaper)
covering the attic ceiling covering the attic ceiling
joists a minimum 12joists a minimum 12””..
Fiberglass Insulation Fiberglass Insulation
properly installed.properly installed.
PROPERLY INSTALLED PROPERLY INSTALLED
INSULATIONINSULATION
Quality of Insulation Quality of Insulation installation (QII) and installation (QII) and touching all sides of touching all sides of wall cavity.wall cavity.
88””+ of Spray+ of Spray--in foam in foam at roof rafters. at roof rafters.
This is what we call a This is what we call a tightly sealed Building tightly sealed Building Envelope.Envelope.
INDOOR AIR QUALITY INDOOR AIR QUALITY
SOLUTIONSSOLUTIONS
ZeroZero--VOC paints VOC paints
throughout the interior throughout the interior
of the home.of the home.
Fireplace that is 94% Fireplace that is 94%
efficient and vented to efficient and vented to
the outside.the outside.
INDOOR AIR QUALITY INDOOR AIR QUALITY
SOLUTIONSSOLUTIONS
Tankless Water Tankless Water
Heater to the outside Heater to the outside
of house.of house.
Sealing off the return Sealing off the return
chase Plenum of the chase Plenum of the
HVAC System.HVAC System.
HOME PERFORMANCE with HOME PERFORMANCE with
ENERGY STARENERGY STAR
One One ““HOTHOT”” computer. computer.
One One ““HOTHOT”” Jason !!!Jason !!!
HOME PERFORMANCE with HOME PERFORMANCE with
ENERGY STARENERGY STAR
Infrared Camera tells Infrared Camera tells us a lot about hot and us a lot about hot and cold spots throughout cold spots throughout the houses.the houses.
Temperature changes Temperature changes are easy to see and are easy to see and to define with to define with diagnostic testing diagnostic testing equipment.equipment.
Missing Insulation as Missing Insulation as seen from inside the seen from inside the attic area.attic area.
Infrared picture as Infrared picture as seen from in the seen from in the bedroom side of bedroom side of missing attic missing attic insulation.insulation.
HOME PERFORMANCE with HOME PERFORMANCE with
ENERGY STARENERGY STAR
BLOWER DOOR TESTBLOWER DOOR TEST
Blower door tests will tell us how leaky Blower door tests will tell us how leaky someonesomeone’’s home really is. Then we can use s home really is. Then we can use Building Science Techniques to correct the Building Science Techniques to correct the issues within the home.issues within the home.
DUCT BLASTER TESTDUCT BLASTER TEST
Duct Blasters show us how leaky the duct Duct Blasters show us how leaky the duct
systems are. Then we take the necessary systems are. Then we take the necessary
measures to correct those issues as well.measures to correct those issues as well.
INFRARED CAMERAINFRARED CAMERA
Entry front door not Entry front door not
performing properly.performing properly.
Walls have multiple Walls have multiple
air infiltration issues air infiltration issues
that need to be that need to be
resolved.resolved.
Home PerformanceHome Performance
Once we implement Once we implement Home Performance with Home Performance with Energy StarEnergy Star--
We DO NOT need all this We DO NOT need all this solar to be green.solar to be green.
Take care of the Take care of the ““Building Building EnvelopeEnvelope”” firstfirst--
Then we need as little Then we need as little solar as possible.solar as possible.
Living Green HomesLiving Green Homes
Jason ScheurerJason Scheurer
Office (714) 841Office (714) 841--30803080
Cell (714) 330Cell (714) 330--39443944
Jason@[email protected]
Penny@[email protected]