LI Complete Control Level Interior (LIC8, LIC24, LIC48, LICA8, LICA24, LICA48)
Complete scheduling, monitoring, and reporting capabilities via exclusive WinControl software
Priority array based logic engine for simple execution of complex control scenarios
• Networkupto500panelsviaopentopologydigitaldatabus
• CreateuserprogrammingofflineusingWinControlsoftwareandtransfertopanels
• ImportsitedocumentationfromWinControlDesignerprojectdesignanddocumentationsoftware
• Programmablegroupcodeswithscenariobasedlogicprovidesystem-widecontrol
• PowerfuldataloggingfeaturewithmanualandautomaticlogtransfertoPC
•OptionforseamlessbuildingsystemintegrationusingBACnetprotocol
• SupportsWattStopperoccupancysensorsdirectlywithoutpowerpacks
TheWattStopperLightingIntegratorCompleteControl(LIC)systemisafullfeaturednetworkedcontrolsystemthatprovidesthemaximumflex-ibilityforlightingcontrolbyprovidingbothpanelbasedanddistributedloadcontroloptions.Adigitalcommunicationbusallowsuserprogram-minggeneratedattheWinControlworkstationtobetransferredtothepanelswhereitrunsautonomously.Onceloadedintothepanels,thelightingautomationfeaturesoperatewithouttheneedforanonlinePC.Thisdistributedprocessingcapabilityensuresahighdegreeofreliability.LICincorporatesallthebasefeaturesoftheLightingIntegratorhardwareplatformincludingtheHDRmechanicallylatching,heavydutyrelay.
LICApanels,withlocaldatalinesupport,providelocalDatalineSwitchfunctionality.
OperationDescriptionProduct Overview
Features • GeneratedetaileddocumentationreportsofallaspectsofsystemhardwareandsoftwareviaWinControlsoftware
• Programmableanaloginputsprovidemultiplesetpointsforphotocellsorotheranalogdevices
• Programmabledatalineswitchesconnecttopanelwith4wireopentopologydigitaldatabus
• ProvidesfullsupportforWattStopperASseriesAutomaticWallSwitch
• RemotenetworksupervisionandprogrammingviaTCP/IPconnectionusingoptionalWebLinkdevice
• QualifiesforuseonARRA-fundedprojects
Compatible with legacy Complete Control systems
Distributed processing architecture with robust 2-wire digital network communications
EachLICpanelstorestheusergeneratedpro-gramminginnonvolatilememoryhousedwithintheCompleteControlintelligencecard.Thiscontrollermonitorsallinputsandusesauniquepriorityarraybasedlogicenginetogeneratetheappropriateloadresponse(relaycontrol)basedonsimpleorcomplexcombinationsofinputtrig-gersthatcanincludeschedules,overrideswitches,occupancysensors,photocellsandsignalsfromotherbuildingsystems.
LICfeaturesalibraryofscenariobasedcontrolschemesthatprovidepowerfulcontroloptionswithoutthecomplexityoflowleveluserprogram-ming.Thesecontrolscenariosincludeprovisionsforcommonarealogicwithegress,cleaningcrewoverrides,loadshed,forceon,forceoff,blinkwarn,andafterhourtimedelay.
Syste
m&
Enclo
sures
12:00
Lig
ht
ing
Co
nt
ro
L P
an
eL
Sy
St
em
S
www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5
Syste
m&
Enclo
sures
LIC System Layout
LIC Specifications
• Panelconfigurationsprovide8,24,or48relaysizeinteriors
• Standardrelay,individuallyreplaceableWattStopperHDRseries,latchingSPST,meetsnewNEMAelectronicballastrequire-ments,14,000AmpsSCCR,withintegralmanualoverride
• Digitalnetworkdataline,onepairtwistedandshielded,opentopologyallowslinear,star,andTnetworkconfigurationsforpanels/con-nectivity4000’maxlength
• NetworklinkdeviceprovidesRS-232connec-tiontodigitaldatalineforPCorWebLinkandvisualindicationofsystemoperation
• Analoginput,12VDCsourceprovided,0–4VDCinput,8inputsprovidedpergroupswitchingcard
• Optionallocaldataline,twopairtwisted,opentopologyallowslinear,star,andTconfigu-rations,63HDLSseriesswitchaddressesavailableperdataline,1500’maxlength(LICAoption)
• Analogsetpoints,32maximumperpanel,highset/lowsetwithindividualhigh/lowtimedelays
• Directwireswitchinputs,oneeachperrelayandgroupswitchchannel,automaticallycon-figureforoccupancysensoroperation
• Pilotlightoutputperrelayandgroupswitchchannel,configurableforanyClass2voltage
• DINrailmountingforautomationmodules
• ULlisted,oneyearwarranty
Panel System Layout and Configuration
Local Dataline (4-wire)
OccupancySensor
Analogphotocell
DatalinePower Supply
CompleteControl Cards
Global dataline (2-wire)
DataComunications
link
LIC LIC LICA
Dataline Switches
WinControlPC
OptionalLocalDataline
Note:Datalinepowersupplyrequiredinonepanelonly.
12:00
Lig
ht
ing
Co
nt
ro
L P
an
eL
Sy
St
em
S
www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5
WattStopper’sLightingIntegrator(LI)isalowvoltage,relaybasedlightingcontrolpanel.Panelinteriorsareconfiguredas8,24or48relaycapacitywiththequantityofrelaysinstalledascalledforontheorder.Theinteriormountsintotheappropriateenclosure.TheLIpanelenclosureandcoverareshippedseparatelyfromthepanelinteriortofacilitateprojectrough-inrequirements. Group Switching
Description
Groupswitching,alsoreferredtoasSmartwiredswitching,isasimplebuttonpressinterfacethatallowsanyquantityofrelaysinapaneltobeassignedquicklytoeachgroupswitchingchannelforcommonon/offcontrolorforpattern(scene)control.Eachoftheeightchannelsisprovidedwithanoverridepushbutton,LEDstatusindicatorandterminalsforconnectionofwallswitchesandoccupancysensors.Aneightor24sizepanelcanbeorderedwithonegroupswitchcard(8channels),48sizepanelscanhavetwogroupswitchcardsforatotalof16channels(8controllablebyscheduling,eightbyswitchingonly).
Operation
LIrelaysaredriventoalatchedonoroffpositionviaa24voltDCpulsegeneratedbytherelaydrivercards.Amomentarypushbuttonisprovidedforeachrelaytomanuallytoggletherelay’sstatewitheachbuttonpress.Anisolatedcontactintherelaysprovidespositivestatusfeedbacktotherelaydrivercircuits,whichareannunciatedbyanLEDassociatedwitheachrelay.Removableterminalblocksallowconnectionofdirectwiredlowvoltagedevicesforremotecontrolofrelays.
Inputscanbewiredtoaccommodatemaintainedormomentarythreewireortwowireinputs.TheswitchinputcircuitsareautosensingandwillautomaticallyconfigureappropriatelywhenWattStopperoccupancysensorsareconnected.
Operation (cont’d.)General LI Information
Syste
m&
Enclo
sures
• InteriorprovidescompleteisolationbetweenlineandlowvoltagewhenusedwithanLIenclosure(LENC)
• Individualplug-in,latchingstylesinglepoleHDRrelayswithisolatedpilot/statuscontacts
• Integralpushbuttonoverride,statusLED,andpilotlightoutputperrelay
• Twoslotsavailableforoptionalautomation,networkingandintegrationcontrolcards
• SupportsWattStopperlowvoltageoccupancysensorswithoutneedforseparatesensorpowerpacks
• Smartwiringfeatureallowsgroupingofrelaysforcommoncontrol
• DINrailmountingprovidedwithintheClass2sectionformountingofoptionalaccessories
• Controlmulti-polecircuitswithoptionalcontactorsandcompatibleLENCenclosure
• Optionalconfigurationavailableforuseonemergencylightingcircuits
12:00
Lig
ht
ing
Co
nt
ro
L P
an
eL
Sy
St
em
S
www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5
Panel Interior Dimensions
General LI Specifications
• Interiorcapacity:
-8SPSTrelays
-24SPSTrelays
-48SPSTrelays
• Inputvoltageoptions,120/277V60Hz,120/347V60Hz,240V50Hz
• Groupswitching,eightchannelsperinstalledgroupswitchingcard.OnecardmaxperLI8andLI24.TwocardsmaxLI48.
• Lowvoltageswitchinputs,removableterminalblockswithtool-lessconnection,configurableforthreewiremomentary,twowiremomentary(toggle),andtwowiremaintaineddrycontactswitchesorWattStopperoccupancysensors.
•Accessorypoweravailable
-LI8:1000MA@24VACor800MA@24VDC
-LI24andLI48:1400MA@24VACor800MA@ 24VDC
•SCCR(shortcircuitcurrentrating)14,000ampswithHDRHeavyDutyRelay
•HDRSPSTrelays:
-Coilvoltage,24VDC,pulseONandpulseOFF
-Mechanicallylatchedcontacts
-½”K,O,mounting,LVplug-connection,individuallyreplaceable
-Contactratings 30ampsballast@277V 20ampsballast@347V 20ampstungsten@120V 30ampsresistive@347V 1.5HP@120V -Endurance:300,000mechanicalcycles
• Pilotlightoutput,24Vrectifiedor24VAC,othervoltagesconfigurablewithexternalpowersupply
• Oneyearwarranty
Ordering Information
CapacityVoltageOptionsRelayCountGroupSwitchCardEmergencyRelaysCoilVoltageDatalinePowerSupply
115/277
115/347
240
LIC8
LIC24
LIC48
LICA8
LICA24
LICA48
___HDRrelaysinstalled(maxofinteriorcapacity)
___GScards(max1in8,24,2in48)
115
240
277
347
InstalledOptions
Pub.No.21906rev.5/2013
10.5"26.67 cm
23.37"59.37 cm
13"33.02 cm
14"35.56 cm
14"35.56 cm
8 relayinterior capacity
24 relayinterior capacity
48 relayinterior capacity
35.75"90.80 cm
Syste
m&
Enclo
sures
___EMrelaycount(Notavailablein8-relaysizepanels;max.of24in24-relayor48-relaysizeinterior)
Interior
___DPdatalinepowersupply(onerequiredpereachnetwork)