light output uniformity for csi(tl) as supplied by manufacturers…
DESCRIPTION
Light Output Uniformity of Long CsI(Tl) crystals - the “bottle-neck” for gamma and proton spectroscopy. Light Output Uniformity for CsI(Tl) as supplied by manufacturers…. …and Energy Resolution for gammas, measured by a APD ( 5x5), when irradiating the whole crystal volume…. *. source. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Light Output Uniformity for CsI(Tl) as supplied by manufacturers…](https://reader036.vdocuments.net/reader036/viewer/2022083006/56813b21550346895da3d892/html5/thumbnails/1.jpg)
Light Output Uniformity of Long CsI(Tl) crystals -
the “bottle-neck” for gamma and proton spectroscopy
C sI (T l ), 20x20x100 + A P D
K har ' kov, 05 St. G obain, J 701
D istance form C sI fr ont face
C hannels
C hannels
dL/L
Cou
nts
Cou
nts
C o60 C o60
C s137 C s137
9. 4%
12. 2%
%
16. 0%
0. 96
0. 98
1
1. 02
1. 04
0 2 4 6 8 10
0. 96
0. 98
1
1. 02
1. 04
0 2 4 6 8 10
0
250
500
750
1000
200 400 600 800 10000
250
500
750
1000
200 400 600 800 1000
0
500
1000
100 200 300 400 5000
500
1000
100 200 300 400 500
Light Output Uniformity for CsI(Tl) as supplied by manufacturers…
…and Energy Resolution for gammas, measured by a APD ( 5x5), when irradiating the whole crystal volume…
*
CsI(Tl), L=110 mm
source
20x20
Lund-Dubna, VC_2007_12_13
L=110 mm
![Page 2: Light Output Uniformity for CsI(Tl) as supplied by manufacturers…](https://reader036.vdocuments.net/reader036/viewer/2022083006/56813b21550346895da3d892/html5/thumbnails/2.jpg)
D istance along C sI , mm50 100
Ligh
t var
iatio
n, d
L/L
1. 0
0. 95
0. 90
a) dL /L = 0. 0%
b) dL /L = 5. 0%
c) dL /L = 10. 0%
a)
b)
c)
P roton E nergy, M eV
Ligh
t Out
put (
arb
. un
its) dL O = 3. 6%
dL O = 0. 0%
dL O = 1. 75%
3000
3500
4000
4500
5000
5500
100 120 140 160 180 200
Effect of crystal Light Output nonuniformity ( a)- 5%, b)-10% on the Light collected by Photodetector.
Calculated for Protons.
For Gammas – the picture looks similar, but with energy scaled by factor 1/4 - 1/5 .
Conclusion – dLO/LO must be less than 1% along the length of crystal
Straggling and Nonlinearity for Protons and Gammas due to dL/L
Lund-Dubna, VC_2007_12_13
![Page 3: Light Output Uniformity for CsI(Tl) as supplied by manufacturers…](https://reader036.vdocuments.net/reader036/viewer/2022083006/56813b21550346895da3d892/html5/thumbnails/3.jpg)
2007/12/11 18. 15
5
L = 110 mmC sI (T l )
20x2
0
23x2
3
L=11
0 m
m
Ene
rgy
Res
olut
ion,
%
C hannels
E nergy, M eV
Source
5. 6%
1. 17 M eV
1. 33 M eV
M easured by P D , 10x10
by A P D , 5x5
by A P D , 10x10
0
200
400
600
800
1000
1200
1400
1600
200 400 600 800 1000 1200 1400
1
10
10-1
1
Test with highly uniform in Light Output Crystal , L=110 mm, dL/L <0.7%
CsI(Tl) – 20x20 – 110 – 23x23 mm**3
Irradiated for 110 mm distance…
Photodetectors:
PD – 10x10 mm**2
APD – 5x5 mm**2 / <M>=40
APD – 10x10 mm**2 / <M>=50
Our data… compare APD of 5x5 and 10x10 mm**2 !!!!
Published data,
10x10x10 mm**3 CsI(Tl)+ 10x10 APD!!!
Lund-Dubna, VC_2007_12_13
![Page 4: Light Output Uniformity for CsI(Tl) as supplied by manufacturers…](https://reader036.vdocuments.net/reader036/viewer/2022083006/56813b21550346895da3d892/html5/thumbnails/4.jpg)
C hannels
P ulser1. 17 M eV1. 33 M eV
A P D , 10x10C sI (T l )
C sI (T l )A P D , 5x5
P ulser
V M 2000(refl ector )
S_ A P D / S_ L ighG uide= 1.
S_ A P D / S_ L ighG uide = 0. 25
L (5x5)/L (10x10)= 0. 65
0
100
200
300
400
500
200 400 600 800 1000 1200 1400
0
100
200
300
400
500
600
200 400 600 800 1000 1200 1400
a)
b)
Effect of VM200 ( ESR) Light Guide reflector on Light collection and Energy Resolution
a) - Active area of APD = Active area of Light Guide, 10x10 mm**2. S_APD/S_LG =1.0
b) - Active area of APD = 0.25 of Active area of Light Guide, 5x5 mm**2.
S_APD/S_LG =0.25
Light Collection coefficient,
L(5x5)/L(10x10) = 0.65, due to the VM2000
(ESR) reflector, covering an extra surface
By using an APD of 10x10 mm**2 we can gain around 12% in the energy resolution as compared with the APD of 5x5 mm**2
Lund-Dubna, VC_2007_12_13
![Page 5: Light Output Uniformity for CsI(Tl) as supplied by manufacturers…](https://reader036.vdocuments.net/reader036/viewer/2022083006/56813b21550346895da3d892/html5/thumbnails/5.jpg)
Some Conclusions and Plans for Future R&D
Lund-Dubna, VC_2007_12_13
1. Light Output uniformity for Long crystals is more important than the active area of the APD2. For the highly uniform in L.O. crystals we can get almost ideal Energy Resolution3. New groups must be involved in the Uniformity Problem for real Califa geometries
Plans for nearest future:
1. Light Uniformity adjustment for the real CALIFA crystal geometry
2. Tests with APD’s, PMT’s / like R7400U-3, 20 – insensitive to magnetic field
3. To mount CsI(Tl) “demonstrator” for bench and in-beam tests