lighting
TRANSCRIPT
![Page 1: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/1.jpg)
1
Fundamentals of Energy Efficient Lighting
Presented By:
Ken Currie, PhD, P.E.
July 17, 2013
![Page 2: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/2.jpg)
2
Building Lighting Energy
![Page 3: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/3.jpg)
3
Lighting Type First Cost
![Page 4: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/4.jpg)
4
Lighting Type Life Cycle Cost
![Page 5: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/5.jpg)
5
Lighting Energy Efficiency
![Page 6: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/6.jpg)
6
Efficient Lighting
![Page 7: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/7.jpg)
7
Amount of Light
![Page 8: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/8.jpg)
8
Other Considerations
![Page 9: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/9.jpg)
9
Light & Color
![Page 10: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/10.jpg)
10
Color Temperature
Color Temperature is noted in degrees Kelvin* or °K
3,000°K - Warm White
3,500°K - Neutral
4,100°K Cool White
* The Kelvin Scale is defined as Celsius plus 273.
![Page 11: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/11.jpg)
11
Color Temperature Definition
• the electromagnetic radiation emitted from an ideal black body
• 1,700 K Match flame
• 1,850 K Candle flame, sunset/sunrise
• 2,700–3,300 K Incandescent lamps
• 3,000 K Soft White compact fluorescent lamps
• 3,200 K Studio lamps, photofloods, etc.
• 3,350 K Studio "CP" light
• 4,100–4,150 K Moonlight
• 5,000 K Horizon daylight
• 5,000 K tubular fluorescent lamps or Cool White/Daylight CFL
• 5,500–6,000 K Vertical daylight, electronic flash
• 6,500 K Daylight, overcast
• 5,500–10,500 K LCD or CRT screen
• 15,000–27,000 K Clear blue poleward sky
![Page 12: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/12.jpg)
12
Typical Color Temperatures
Incandescent ……... 2,750°K – 3,400°K
Fluorescent ……….. 2,700°K – 6,500°K
Mercury vapor ….. 3,300°K – 6,000°K
Metal Halide ……… 3,000°K – 4,300°K
High Pressure
Sodium …………...... 1,900°K – 2,200°K
Induction …………… 3,000°K – 4,000°K
![Page 13: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/13.jpg)
13
Color Rendering Index (CRI)
Color Rendering Index is a scale from 0-100 that indicates the accuracy with which a lighting source can reproduce colors. The higher the CRI value the more accurate the color reproduction.
![Page 14: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/14.jpg)
14
Color Rendering Index (CRI)
Typical high CRI values: 80 to 90
Typical good CRI values: 65 to 80
Typical poor CRI values: <65
Note: The CRI for standard Low Pressure Sodium lamps is extremely poor.
![Page 15: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/15.jpg)
15
Typical CRI Values
Incandescent …………….. 100
Fluorescent ………………. 60 - 90
Mercury vapor …………….15 - 30
Metal Halide ……………… 60 - 90
High Pressure Sodium ….. 10 - 60
Low Pressure Sodium ….. Negative
Induction ………………….. 85
LEDs……………………………. 30 - 60
![Page 16: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/16.jpg)
16
Lamp Life Comparison
![Page 17: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/17.jpg)
17
Light & Distance
![Page 18: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/18.jpg)
18
Light & Distance
The lighting level drops off as the square of the distance.
E = I/d2
Where: E = Illuminance (footcandles or lux) I = Intensity of lighting in Candelas D = Distance from the source
![Page 19: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/19.jpg)
19
Light & Distance
Therefore, even small changes in the mounting height of a luminaire can have a significant impact on the lighting level.
![Page 20: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/20.jpg)
20
Lighting Levels
• Specific tasks to be performed
• Time required for each task
• Speed and accuracy
• Age of occupants
• Safety and security
• Aesthetics
• System operating cost
![Page 21: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/21.jpg)
21
Lighting Sources
![Page 22: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/22.jpg)
22
Lighting Sources
![Page 23: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/23.jpg)
23
Sources Efficacy
0
20
40
60
80
100
120
140
160
Tungsten LEDwarm Mercury Vapor LEDcool Fluorescent Induction Metal Halide HPS LPS
Lum
en
s/W
att
Lighting Source Efficiency
![Page 24: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/24.jpg)
24
Source Efficacy
![Page 25: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/25.jpg)
25
Reflectors
![Page 26: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/26.jpg)
26
Reflectors
• Reflectors allow the user to direct most of the light downward toward surfaces of interest instead of lighting the ceiling.
• Reduce electric consumption by reducing the number of lamps required for desired light output.
• 3 Types (Reflective Efficiency) – Standard Aluminum Reflector (86%)
– Reflective White Paint (91%)
– Enhanced Specular Aluminum (95%)
![Page 27: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/27.jpg)
27
LED Lamps – Efficacy
![Page 28: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/28.jpg)
28
Basic Principles of Lighting Energy Management
1. If you don’t need it, turn it off
- Employee Awareness, Sensors,
Timers, Photocells, Timed Switches, Energy Management Systems, etc.
2. Proper maintenance
- Group cleaning and relamping
![Page 29: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/29.jpg)
29
Basic Principles of Lighting Energy Management
3. Enhanced lighting control
- Photocells and occupancy sensors
4. More efficient sources
- Electronically ballasted fluorescent fixtures,
- Compact fluorescents - Induction lamps - Light emitting diodes (LEDs)
![Page 30: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/30.jpg)
30
Comparisons & Case Studies
![Page 31: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/31.jpg)
31
Incandescent Upgrades
![Page 32: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/32.jpg)
32
Case 1: Manufacturer
![Page 33: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/33.jpg)
33
Case 1: Manufacturer
![Page 34: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/34.jpg)
34
Case 1: Manufacturer
![Page 35: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/35.jpg)
35
Case 2: Automotive Components Manufacturer
Electric Rates: Usage: $.040/kWh Demand: $0.0/kW
Operating Hours of Fixtures: 8,760 hours/yr
Background: (31) Exit fixtures are equipped with (2) 20-watt lamps each
Power Rating: 40-watts Annualized Maintenance Cost per fixture: $25.81
Recommendation: Replace with (31) LED exit fixtures, each with (2) 2-watt LED lamps
Power Rating: 4-watts Annualized Maintenance Cost per fixture: $9.32
![Page 36: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/36.jpg)
36
Savings: Usage: 9,776 kWh/yr $391 / yr
Demand: 13 kW/yr $0 / yr Maintenance: $511 / yr Total Savings: 902 / yr
Implementation Cost: $1,513
TVA Rebate: $978
Simple Payback Period: 1.68 years (0.59 yrs)
Case 2: Automotive Components Manufacturer
![Page 37: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/37.jpg)
37
Case 3: Auto Parts Manufacturer
Electric Rates: Usage: $.065/kWh Demand: $12.47/kW
Operating Hours of Fixtures: 8,736 hours/yr
Background: There are (114) 400-watt metal halide fixtures throughout the facility
Power Rating: 450-watts/fixture Annualized Maintenance Cost per fixture: $19.71
Recommendation: Replace with (114) 220-watt T8 fluorescent fixtures
Power Rating: 220-watts Annualized Maintenance Cost per fixture: $11.76
![Page 38: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/38.jpg)
38
Savings: Usage: 229,058 kWh/yr $14,889 / yr Demand: 314.6 kW/yr $3,924 / yr Maintenance: $906 / yr Total Savings: $19,719 / yr
Implementation Cost: $45,326
TVA Rebate: $22,906
Simple Payback Period: 2.30 years (1.14 yrs)
Case 3: Auto Parts Manufacturer
![Page 39: Lighting](https://reader033.vdocuments.net/reader033/viewer/2022060115/557c5b5bd8b42a0b4b8b4cfd/html5/thumbnails/39.jpg)
39
Questions ???????????