    Logical Analogy and Electrical Argumentation about Steel Tower as

    Down Conductor is in Accordance with

    Standard Installation Lightning Protection System

    An article for consideration

    By:

    Januargo

    National CME and Design

    HCPT Project

  • 8/14/2019 Lightning Protection Article-E

    2/16

    Author : Januargo S. Baskoro 2

    Date : Feb 04, 2008

    Contents

    I. Introduction ................................................................................................................. 3

    II. Logically Analogy ....................................................................................................... 5

    III. Standard References .................................................................................................. 10

    IV. Electrically Argumentation Regarding Tower as down conductor ........................ 11

    V. Currently Cases and The Analysis ............................................................................ 14

    VI. Conclusion and Solusion Proposal ........................................................................... 16

  • 8/14/2019 Lightning Protection Article-E

    3/16

    Author : Januargo S. Baskoro 3

    Date : Feb 04, 2008

    I. Introduction

    As everybody understood that high building such as telecommunication tower is

    something that inviting lightning. Inviting means that when there is no high building at

    some area then lightning doesnt come to there unless high level ionization in air at thearea carry the ion to jump from cloud to earth. But if the ionization isnt happened then

    lightning jumping only between cloud to another cloud.

    Lightning is a jumping ion which normally spread at the surface of cloud to the

    counterpart ions which have inverse polarity toward neutralization condition. At some

    cloud are not always have same polarity of ion, for example one group of cloud consist of

    negative ion (-) then another group of cloud could consist of positive ion (+). Whenever the

    two of group become closer until a distance which the energy of charged are strong enough

    to jump, so lightning between clouds are exist. But if, in the way of running cloud doesnt

    meet the counterpart ion, then the ions are going down because of earth gravitation effect

    and forming a path from cloud to earth thus lightning may be happened from cloud to earth

    because earth is an extraordinary ions source. The occurrence of lightning from cloud toearth is more possible if there is a better way to reach, those are a high building and tower.

    Figure 1. Lightning between clouds

  • 8/14/2019 Lightning Protection Article-E

    4/16

    Author : Januargo S. Baskoro 4

    Date : Feb 04, 2008

    Figure 2. Lightning between cloud to earth

    Figure 3. Lightning from cloud to earth via tower

  • 8/14/2019 Lightning Protection Article-E

    5/16

    Author : Januargo S. Baskoro 5

    Date : Feb 04, 2008

    II. Logically Analogy

    In accordance with previous explanation that lightning is electrical ions that jump each

    other with counterpart ions to find neutral condition. The moving ions become an electric

    current when it is passed by a conductor. Basic understanding of electrical behavior is

    always corresponding to liquid behavior because liquid is visible to be analyzed of its

    movement. Electricity is flowing from higher potential to lower potential. Similar with thisthat liquid is flowing from higher pressure of place to lower pressure of place. Moving

    electricity need a conductor, liquid need a pipe to move nicely as expected. Size of

    conductor is defining of ability to conduct the electric current, size of pipe is also defining

    of pipe ability to be passed by liquid.

    Logical analogy of lightning protection system at telecommunication tower that on

    struck by lightning can be corresponded with water tank system with its pipe channels and

    dissipation pipes as shown in Figure 4. The picture is showing how liquid from top tank

    flow to bottom via pipe channel, P1 and P2, and the liquid is dissipated completely if the

    dissipation pipes are enough.

    Figure 4. Logical analogy lightning protection system as tank system with the liquid.

    But, when number of dissipation pipes is reduced then liquid will flow to out side via

    any pipe that connected to the system as shown in Figure 5. If any part of the out side pipe

    consist small cross section and thin, then at that part will receive big pressure thus the

    leakage possibility on it can be exist. The illustration is shown in Figure 6.

  • 8/14/2019 Lightning Protection Article-E

    6/16

    Author : Januargo S. Baskoro 6

    Date : Feb 04, 2008

    Figure 5. Liquid flowing to outside via a pipe that connected to the system.

    Figure 6. A small pipe exist at outside pipe.

    In Figure 4, 5 and 6 shown system that using 2 kind of channel pipe, P1 and P2.

    Assuming that using 1 channel pipe, P2, is enough actually then usage of channel pipe, P1,

    giving an extra channel excessively, meaning, the availability of P2 may be removed

    because P1 is so bigger than P2. Figure 7, 8, and 9 are showing the system with single

    channel pipe.

  • 8/14/2019 Lightning Protection Article-E

    7/16

    Author : Januargo S. Baskoro 7

    Date : Feb 04, 2008

    Figure 7. Tank system in figure 4 with single down pipe.

    Figure 8. Tank system in figure 5 with single down pipe.

    Figure 9. Tank system in figure 6 with single down pipe.

  • 8/14/2019 Lightning Protection Article-E

    8/16

  • 8/14/2019 Lightning Protection Article-E

    9/16

    Author : Januargo S. Baskoro 9

    Date : Feb 04, 2008

    Figure 12

    Figure 13

    Figure 14

  • 8/14/2019 Lightning Protection Article-E

    10/16

  • 8/14/2019 Lightning Protection Article-E

    11/16

  • 8/14/2019 Lightning Protection Article-E

    12/16

    Author : Januargo S. Baskoro 12

    Date : Feb 04, 2008

    Capability of conductor to conduct ions is different depending on the material composed

    and it is called conductivity. Conductivity is formulated as:

    nq=

    where,

    n is number of electric charge carries,

    q is the charge of the ion,

    is the mobility of the charged species.

    Conductivity is not familiar at peoples ear and it is not understood generally. People can

    understand about resistivity that simply inverse of conductivity,

    1=

    And resistance is an extrinsic property of a device which is represented by the equation

    A

    lR =

    where,

    R is resistance of material ( ),

    is resistivity of material ( .m),

    l is length of material (m) and

    A is its cross sectional area (m2)

    once more simply equation that taken from basic electronic knowledgement about paralel

    combination of resistance is,

    RxRRR

    1...

    2

    1

    1

    11+++=

    According to Table 1, shown that each material such as Copper, Aluminium, and Steel has

    different resistivity, those are

    - Copper = 1.7241x10-6 .cm or equal with 1.7241x10-8 .m- Aluminium = 2.284x10-6 .cm or equal with 2.284x10-8 .m- Steel = 10.4x10-6 .cm or equal with 10.4x10-8 .mSo, for copper cable with cross-sectional area 50 mm2 and its length is as height as tower,

    lets say 80 m, the resistance value can be calculated as

    6

    8

    1050

    80107241.1

    =R

    =R 2.75856x10-2

    =R 0.027586

  • 8/14/2019 Lightning Protection Article-E

    13/16

    Author : Januargo S. Baskoro 13

    Date : Feb 04, 2008

    Then for resistance value of Aluminium cable with cross-sectional area 70 mm2 is,

    6

    8

    1070

    8010284.2

    =R

    =R 2.6103x10-2

    =R 0.026103

    Thus for galvanized steel that has dimension 50mm x 3mm is,

    4

    8

    10150

    80104.10

    =R

    =R 5.5467x10-4

    =R 0.055467

    Base on standard value of resistance for down conductor that states not bigger than 0.2 so

    the value as result of calculation above are so much less, in that means the three of thosecomponent are acceptable to be used.

    Table 1. Resistivity of material

  • 8/14/2019 Lightning Protection Article-E

    14/16

    Author : Januargo S. Baskoro 14

    Date : Feb 04, 2008

    If the resistance calculation is simply implemented to tower shown as follow. For example

    72 m 4 legged Angular Tower, many angular tower have same type of top 10 m section,

    and the top section has smallest size of legs than bottom section. From tower data, each top

    leg is using angle bar 80 x 80 mm with thickness of 8 mm, see Figure 16.

    Figure 16. Angle bar 80mm x 80mm x 8mm

    The section area is,

    1216)872()880( =+= xxA mm2

    = 12,16x10-4

    m2

    Assume that as height as tower are using leg with same type angle bar, so the resistance of

    single leg is,

    4

    8

    1016.12

    72104.10

    =R

    =R 0.006158

    And value of all leg as paralel combination is

    0.006158

    1

    0.006158

    1

    0.006158

    1

    0.006158

    11+++=

    R

    0.006158

    41=

    R

    006158.04 =R

    =R 0.001539

    This is a very small value (remember the calculation was assuming that tower use same

    smallest size of leg as long as height of tower, so the actual could be smaller than the

    calculation) and it is acceptable to be used as down conductor.

    V. Currently Cases and The AnalysisSo many reports about damage accident that caused by lightning hit the tower such as

    1. KWH meter in tower location is burn.2. Neighbors electric equipments are burn, like TV, Radio, Water pump, Lamp etc.

    Many opinions arise that says:

  • 8/14/2019 Lightning Protection Article-E

    15/16

    Author : Januargo S. Baskoro 15

    Date : Feb 04, 2008

    1. It is happened because of tower doesnt equip with down conductor2. It is happened because there is no control pit and the grounding bar is not copper3. It is happened because the grounding resistance is not below than 1 4. It is happened because of electromagnetic effect when lightning is striking

    Opinion 1,

    It is denied with the explanation in section III and section IV.

    Opinion 2,

    It is said without analysis and logically thinking.

    Opinion 3,

    The value of 1 is not mentioned in installation standard of lightning protection

    system or in any standard. IEC 62305-3 standard is defining grounding resistance

    value as 10 and PUIL (Indonesia Standard) is defining grounding resistance

    value as 5

    . Technical explanation of this value is too long to be mentioned in thisdiscussion.

    Opinion 4,

    From the fact in the field, known that portion of damage devices is at power part,

    for example, TV burn, radio burn, water pump burn, lamp burn, etc. Which is

    electromagnetic field does not cause that defection. Electromagnetic effect as

    impact from lightning may cause, human brain disruption, defection on electronic

    device such as computer, digital radio etc, but not in power part. So clearly clarified

    that all of the defections in these cases are not impacted by electromagnetic field

    effect.

    So, the analysis of the accident is,

    When the lightning striking tower, lightning current is carried down to earth via down

    conductor, any down conductor type as mentioned or the tower itself can do the job. In

    earth, the lightning current is dissipated through the electrodes. The capability of electrode

    to be thru by lightning current depend on surface wide of the electrode that contacted with

    earth and impedance of earth self. If number of electrodes are much enough, so the

    lightning current can be dissipated immediately, otherwise the currents are looking for any

    conductor connected that can be passed, and the alternative selected path is PLN line

    toward outside tower area to the neighbor. If the currents that flowing to outside are big,

    the defection as mentioned can be happened particularly if current pass a small conductoror big inductance.

    Because KWH meter has a coil conductor as inductor inside, so it create high impedance

    when a momentary current flow and burn it. Inductor and impedance are not explained in

    this writing.

  • 8/14/2019 Lightning Protection Article-E

    16/16

    Author : Januargo S. Baskoro 16

    Date : Feb 04, 2008

    Every PLN users are suppose to install lightning protection system in their area, but

    unfortunatelly it is not done in Indonesia, so when something happen as impact of the

    lightning in their neighbor, it may impact to them too.

    V. Conclusion and Solusion ProposalSeveral conclusion are taken after all clarification above,

    1. Tower as down conductor is in accordance with installation standard of lightningprotection system.

    2. All currently defection cases are not caused by the installation lightning protectionsystem without separate down conductor. Those are caused by poor installation of

    lightning protection system underground.

    3. The value of grounding resistance can not be taken as the only reference. The numberof grounding electrode is one of other consideration.

    4. Poor installation of lightning protection system in PLN user, so when lightninghappened in some place, the damage devices can be happened in other placesurrounding.

    The author would like to propose two solusions for rectification,

    1. Install more standard rods in the tower area as other path for lightning current to bedissipated by earth. The number of additional rods are using trial an error method

    because nobody knows the big of lightning current is striking. And also, the author

    never did specially the lightning research and never got detail training about lightning,

    but this discourse is based on references, basic electrical and logically thinking.

    2. Install more standard rods at nearest PLN pole which the line is connected to the site.And pull grounding from each line at the pole via arrestor device. This is intended tointercept lightning current that flowing to out side before touching eighbor devices.