line product specifications maxi-amp...

24
Printed in USA P/N 32882 Versatile, cost-effective sensor control modules: models available for use with most Banner photoelectric sensors Power supply, photoelectric amplifier (CD and CM Series), programmable timing logic (CD5, CM5, and CL5 models), and output relay in a single, compact plug-in module CD5, CL5, and CM5 models include 12 selectable delay, pulse, and latch timing logic functions (single or dual functions) All models have 5-amp SPDT electromechanical relay output (solid-state switch optional); some models offer additional solid-state dc switch (see table, page 2) MAXI-AMP ® System Stand-alone sensor control modules Product Line Specifications

Upload: others

Post on 19-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Printed in USA P/N 32882

Versatile, cost-effective sensor control modules: modelsavailable for use with most Banner photoelectric sensors

Power supply, photoelectric amplifier (CD and CMSeries), programmable timing logic (CD5, CM5, and CL5models), and output relay in a single, compact plug-inmodule

CD5, CL5, and CM5 models include 12 selectable delay,pulse, and latch timing logic functions(single or dual functions)

All models have 5-amp SPDT electromechanical relayoutput (solid-state switch optional); some models offeradditional solid-state dc switch (see table, page 2)

MAXI-AMP ® SystemStand-alone sensor control modules

Product

Line Specifications

Page 2: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

CM Series MAXI-AMPmodules contain amodulated photoelectricamplifier for use with thefull complement ofBanner high perform-ance modulated remotesensors (pp. 13-17).

CD Series MAXI-AMPmodules contain amodulated photoelectricamplifier for use withSP12 Series preamplifiedremote sensors(pp. 7-9).

See pages18-21

ON/OFF(output follows input)

105 to 130V acor210 to 250V ac

210 to 250V ac, or12 to 28V dc

See page 22

SPDT E/M relay, isolat-ed solid state DC switch

SPDTelectromechanical relay

105 to 130V ac, or12 to 28V dc210 to 250V ac, or12 to 28V dc

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

Supplies 400mA to powerMAXI-AMP modulesand/or other 10-30V dcsensing devices.

SPDT electromechani-cal relay, plus NPNtransistor solid-stateswitch

105 to 130V ac, or12 to 28V dc

ON/OFF(output follows input)

ON/OFF(output follows input)

SUPPLYVOLTAGE

USED WITH (INPUT)

LOGICFUNCTION(S)

REFER TOPAGES ...

MODULEMODEL

210 to 250V ac, or12 to 28V dc

SPDTelectromechanical relay

105 to 130V ac, or12 to 28V dc210 to 250V ac, or12 to 28V dc

105 to 130V ac, or12 to 28V dc ON/OFF

(output follows input)CD3RA

CD3RB

CD5RA

CD5RB

CM3RA

CM3RB

CM5RA

CM5RB

CL3RA

CL3RB

CL5RA

CL5RB

CI3RC

CP12RC

CP12C

Banner MAXI-AMPs are the most versatile and cost-effectivesensor control modules available anywhere. MAXI-AMP systemmodules combine power supply, photoelectric amplifier (CD andCM series), programmable timing logic (CD5, CM5, and CL5models), and output relay in a single, compact plug-in module. Thisintegrated stand-alone design saves both the expense of a separatecontrol chassis and a substantial amount of control panel space.MAXI-AMP modules are powered directly by AC line voltage.Models are available for either 120V ac or 220/240V ac operation.

CD Series MAXI-AMP modules accept input signals from SP12Series preamplified remote sensors. The preamplified design ofthis system produces exceptionally high noise immunity.

CM Series MAXI-AMPs are designed to work with the popular lineof Banner high-performance modulated remote sensors. The CRSeries is a low-gain version of the CM Series, and is designed foruse with the SP100 Series miniature remote sensors.

CL Series MAXI-AMP modules accept input signals from any

Banner dc module and most dc self-contained sensors.

CI Series MAXI-AMPs provide the power supply, current ampli-fier, and output device for an SMI912 Series intrinsically safesensor. CI Series modules are covered in data sheet P/N 03461.

CD5, CM5, and CL5 models include a multi-function timing logiccircuit, which is easily programmed for twelve of the most popularand useful delay, pulse, and latch functions. MAXI-AMPs offer thechoice of either single or dual timing functions in the same module.

MAXI-AMPs offer a 5-amp SPDT electromechanical relay output.Solid-state switches are available as an option. CD3, CM3 and CL3models offer an additional solid state dc switch.

MAXI-AMPs are contained in a tough NORYL® housing whichmeasures a compact 1.6 x 2.3 x 4". Electrical connections are madevia any standard 11-pole round-pin relay socket (model RS-11).

All MAXI-AMP system modules (except model CI3RC) are CSAcertified and UL recognized.

SPDT electromechani-cal relay, plus NPNtransistor solid-stateswitch

MAXI-AMP SystemStand-alone Sensor Control Modules

See data sheet 03461SMI912 series intrinsicallysafe sensors.

SPDT electro-mechanical relay

2

CL Series modulesaccept signals from anyBanner DC sensor ormodule with NPN(current sinking) output. SPDT

electromechanical relay

No logic function(power supply only)

No output device(power supply only)

Selection of 12 prog-rammable functionsincluding delay, pulse,limit, cycle, and latch

Selection of 12 prog-rammable functionsincluding delay, pulse,limit, cycle, and latch

Selection of 12 prog-rammable functionsincluding delay, pulse,limit, cycle, and latch

SPDT electromechani-cal relay, plus NPNtransistor solid-stateswitch See pages

3-9

See pages10-17

OUTPUTCONFIGURATION

Page 3: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

3

LOGICOUTPUT

ON/OFF

12timingfunctions

SPDT electro-mechanicalrelay, plusNPN transistorsolid-stateswitch

SPDT electro-mechanicalrelay (5 ampcontact rating)

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

MODEL

CD3RA

CD3RB

CD5RA

CD5RB

LOGICOUTPUT

ON/OFF

12timingfunctions

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

CD3A

CD3B

CD5A

CD5B

MODELSUPPLY

VOLTAGE

SPST solid-state contactfor switchingAC loads upto 250V acand 3/4 amp,plus solid-state contactfor switchingDC loads upto 30V dc andup to 50mA.

45678

321

11109

LED +

LED -

PT -

PT +

Auxiliary(see table)

CD3A CD3B CD5A CD5B

Common

ACSupply

DC load

AC load

Load common

Isolatedsolid-state contacts:

Generalized Hookup: models with solid-state output

MAXI-AMP™ CD Series amplifier and control modules aredesigned to operate with SP12 Seriessensors (foreground, see page 7).

SUPPLYVOLTAGE

Programmable Modulated Amplifier and Control Modulesfor use with SP12 Series Preamplified Remote Photoelectric Barrel Sensors

MAXI-AMP CD Series

CD Series MAXI-AMP modules combine power supply, modulatedphotoelectric amplifier, timing logic (in CD5 models) and outputswitch in a single compact, cost-saving module. CD Series moduleswork together with Banner SP12 Series preamplified remote sensors.These sensors offer small size and high power, and are built to operatein highly demanding sensing environments. Their preamplified designgives them exceptionally high immunity to electrical noise (see page 7for further information). MAXI-AMP modules themselves are alsoruggedly built for dependable industrial duty.

CD Series MAXI-AMP modules contain a state-of-the-art BannerCMOS modulator/demodulator/amplifier circuit that offers high im-munity to both ambient light and electrical interference plus reliablesensor performance. All models have Banner's exclusive, patentedAlignment Indicating Device (AID™) system, which lights an LEDindicator whenever the receiver sees a "light" condition, and pulses theLED at a rate proportional to the received light signal strength. MAXI-AMP modules operate from a variety of voltages (see tables at right).

All CD Series modules are programmable for LIGHT or DARK oper-ate. Module input response time may be set at either 1.5 or 15 milli-seconds. The 15-millisecond response mode offers maximum sensingpower (excess gain) with SP12 Series sensors. CD Series modules alsofeature selectable sensor modulation frequencies ("A" and "B"). Thismakes it possible to operate two high-powered SP12 Series sensor pairsusing different modulation frequencies (at the same response timesetting) in close proximity to each other without optical crosstalk.

CD5 models include a versatile multi-function timing logic circuit thatis programmable for 12 popular and useful delay, one-shot, and latchfunctions. Each timing function has a choice of three time ranges.Timing and sensitivity adjustments use rugged 15-turn potentiometersfor very accurate settings. CD Series module circuit design preventsfalse outputs on system power-up.

The output circuit for CD3A, 3B, 5A, and 5B modules consists of twoSPST solid-state switches: one for ac loads of up to 250V ac (3/4 amp),and a second for dc loads of up to 30V dc (50 mA). Models CD5RAand CD5RB have a 5-amp SPDT electromechanical relay. CD3RA andCD3RB modules have a 5-amp SPDT electromechanical relay plus anNPN transistor solid-state switch. For more information on outputcircuit load capability, refer to the tables (right) and the Specificationssection on the next page.

Modulated photoelectric amplifier, power supply,output relay, and versatile timing logic (CD5 models)in one compact, stand-alone package

120 or 240V ac or 12-28V dc operation; requires onlythe addition of a Banner SP12 preamplified opposedmode sensor pair to create a powerful sensing system

CD5 models are easily programmed for any of twelvedelay, one-shot, and latch functions (either single ordual timing); interrogation schemes are possibleusing auxiliary input

Exceptionally high immunity to ambient light andelectrical noise; no false pulse on power-up

Rugged, 15-turn potentiometers for precise timingand sensitivity adjustment; tough Noryl® housing

Includes Banner's exclusive AID™ alignment system

Page 4: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

MAXI-AMP ™ CD Series Modules Specifications

4

Noryl® is a registered trademark of General Electric Co.

SUPPLY VOLTAGE: Models CD3(R)A, CD5(R)A: 105 to 130V ac,50/60Hz (4 VA), or 12 to 28V dc* at 70mA. Models CD3(R)B,CD5(R)B: 210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA.*NOTE: do not connect ac power when using external dc power.

OUTPUT CONFIGURATION:CD3A, CD3B, CD5A, CD5B: Two solid-state SPST switches, one forac loads of up to 250V ac and up to 3/4 amp, the other for dc loads of upto 30V dc and up to 50mA. CD3A and CD3B also have a logic levelcurrent sinking NPN transistor switch at pin #9, maximum load 20mAat 12V dc max.

CD3RA and CD3RB: SPDT electromechanical relay (see specifica-tions, below) plus an NPN transistor solid-state logic-level dc switch (atpin #9, maximum load 20mA at 12V dc max.).CD5RA and CD5RB: SPDT electromechanical relay (specs below).

SPDT Electromechanical Relay Specifications:CONTACT RATING: 250V ac max, 24V dc max, 5 amps max.(resistive load), 1/10 H.P. at 240V ac. Install a transient suppressor(MOV) across contacts that switch inductive loads.CLOSURE TIME: 10 milliseconds max.RELEASE TIME: 10 milliseconds max.MAXIMUM SWITCHING SPEED: 20 operations/secondMECHANICAL LIFE: 20,000,000 operations

AMPLIFIER:RESPONSE SPEED: Programmable for 1.5 or 15 milliseconds. NOTE:use 15 millisecond setting for maximum sensor excess gain.MODULATION FREQUENCY: selectable, "A" or "B".

SENSOR LEAD LENGTH: 100 feet (30 m) maximum, each sensor.When splicing, use separate cable for emitter and receiver, or ordersensors with extended cable length.

SENSOR HOOKUP: One SP12 Series opposed mode sensor pair peramplifier module. Additionally, one self-contained sensor may beconnected at pin #9 (CD5 models) to provide a RESET or INHIBITsignal. +15V dc power for this one additional sensor is available atmodule pin #3 (40mA maximum load).

TIMERS (CD5 models only):Timing ranges: LOW range - 10 to 150 milliseconds

MIDDLE range - 0.1 to 1.5 secondsHIGH range - 1 to 15 seconds

Repeatability: +/-2% of set time over all extremes ofsupply voltage and temperature

ADJUSTMENTS: Miniature switches are provided for programmingof LIGHT/DARK operate, amplifier response time, modulation fre-quency, normally open or normally closed output and timing function(CD5 models). 15-turn clutched potentiometer for gain (sensitivity) andtime settings (CD5 models).

OPERATING TEMPERATURE: 0 to 50°C (+32 to 122°F).

INDICATOR LEDs: Two LEDs. A red indicator LED is "ON" whenthe module output is energized. Exclusive Banner Alignment IndicatingDevice (AID™) system lights another red LED indicator whenever thereceiver "sees" its own modulated light source, and pulses it at a rateproportional to the strength of the received light signal.

CONSTRUCTION: Rugged Noryl® polyphenylene oxide (PPO®)housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base.

Functional Schematics

NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dcdevice (see hookup example, page 9). Current available is 40 mA at 120V ac (240Vac) line level; 30mA at 105V ac (210V ac) line level. Alternately, the module may bepowered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage whenusing external dc power.

NOTE #2: pulling pin #9 low (to common) will inhibit the timing, or reset the latchof CD5 models (see "Description of Logic Functions", page 6).

Models CD3RA, CD3RB

Models CD5RA, CD5RB

Dimension Drawing

NOTE #3: pin #9 of CD3 models may be connected directly as the input to Banner CLSeries MAXI-AMPs or to Banner MICRO-AMP™ or Plug Logic modules (seehookup example, page 9).

Generalized Hookup:models with electromechanical relay output

CD3RACD3RBCD5RACD5RB

SPDT 5ARelay

Output

AC Supply 8

76

54

910

111

23 LED +

LED - CommonPT -

Auxiliary(see table)

PT +

Page 5: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Amplifier Programming (all CD Series modules)

The diagram at the left shows the location of switches 1-4,and the table summarizes the settings required for eachresponse condition.

NOTE: An adhesive-backed mylar label is supplied. It maybe marked to indicate switch programming and then ap-plied to the MAXI-AMP housing as a switch cover.

Factory settings areshown at left. The"underlined" settings intable below are factorysettings.

OFF

ON

OFF

AMPLIFIERPROGRAMMING #1 #2 #3 #4

SWITCH SWITCH SWITCH SWITCH

ON

O

F

F

1

2

3

4

Modulation freq. "A"

1.5 millisecond response

15 millisecond response

Light operate

Dark operate

ON

ON

OFF

Modulation freq. "B"

OFF

ON

ON

OFFON

ON ON ON OFF ON OFF ON

PROGRAMMINGTIMING LOGIC

#1 #2 #3 #4 #5 #6 #7 #8 #9 #10

10

ON

O

F1

2

4

3

F

5

6

7

8

9

SWITCH SWITCH SWITCH SWITCH

ON

ON

ONON

OFF

OFF

OFF

SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH

On/Off

On Delay

Off Delay

On and Off Delay

One-shot

Delayed One-shot

Limit

Repeat Cycle

AC Latch

DC Latch

Delay and Latch

Limit and Latch

ON ON OFF ON OFF ON

OFF OFFOFF OFF ON

ONOFFOFF OFF ON OFF ON

OFF OFFOFF OFF OFF

ON ON ONOFFOFF OFFOFF

OFF ON ON OFF ON

OFF ON ON OFF

ON

ONONON

ONON OFF ONONON

ON ON OFF OFF ONONON

ON ON OFF OFF OFF ONON

N/C Output

N/O Output

.15 Sec. Max. Time

1.5 Sec. Max. Time

15 Sec. Max. Time

OFF

OFF OFF

OFF ON

ON OFF ON OFF ON OFF ON

5

A group of ten switches, located on the side of the module opposite the amplifier programswitches, is used to select the timing logic for the CD5 models.

Switches #1 through #7 are used to select the logic function. Switch #8 programs the output foreither NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds,and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timingmode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However,DELAY and HOLD times are independently adjustable within the selected range.

The diagram shows switch locations, and thetable summarizes the program switch posi-tions.

tion frequencies. This makes it possible to use the two sensor pairsin close proximity without optical crosstalk. Both amplifiers mustbe set for the same response time (either 1.5 or 15 milliseconds) toensure freedom from crosstalk.

Switches #2 and #3 are used to program the amplifier responsetime. The 15 millisecond setting allows SP12 Series sensors tooperate at their maximum excess gain.

Switch #4 is used to select LIGHT OPERATE or DARK OPER-ATE. In the LIGHT OPERATE mode, the output will energize (inON/OFF or LATCH operation) or the timing function will initiate (inDELAY, ONE-SHOT, or LIMIT operation) when the receiver"sees" sufficient light (excess gain greater than 1X). In DARKOPERATE, the output will energize or timing will begin when thereceiver is sufficiently dark (excess gain less than 1X).

Amplifier response conditions may be programmed via the group of fourswitches located on one of the narrow sides of the MAXI-AMP™module.

Switch #1 selects the modulation frequency of the amplifier and theemitter light source. When two pairs of SP12 Series sensors are beingused in close proximity to each other, the modulation frequency switchof their respective CD Series modules should be set to different modula-

Settings illustrated below are factory settings. Factory settings are "underlined" in the table.

Timing Logic Programming (CD5 models)

Page 6: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

LIMIT: The output of the LIMIT function follows the action of the input, as it does with the ON/OFF function. However,an input signal which is longer than the adjustable LIMIT ("HOLD") time will turn the output "off". Removing the input signalresets the timer. This function is sometimes called "TIME LIMITED ON/OFF", and is useful for energy conservation.Grounding pin #9 cancels the output. Lifting the inhibit restarts the LIMIT timer, if an input signal is present.

ON/OFF: ON/OFF operation does not involve timing. The output simply follows the action of the input signal.Grounding pin #9 (AUXILIARY) turns the output "off", regardless of the state of the input signal. This may be accomplishedby closing a switch or relay contact between pins #9 and #1 (common), or by connecting an open collector NPN (current sinking)output of any external dc device directly to pin #9. NOTE: connect the COMMON of any external dc device to pin #1 of theMAXI-AMP to establish a voltage reference between the dc supply for the external device and the internal dc supply of theMAXI-AMP.

ON DELAY: The ON DELAY timer keeps the output "off" until the selected LIGHT or DARK signal has been presentfor the preset "DELAY" time. If the input signal is interrupted, the timing is reset and starts over with the next signal. Groundingpin #9 immediately cancels an output in progress and resets the delay timer. The delay timer is restarted when the inhibit signalis removed, if an input signal is present.

OFF DELAY: The output energizes immediately when the input signal occurs, but does not de-energize until the signalhas been removed for the preset OFF-DELAY ("HOLD") time. Grounding pin #9 prevents an output from occuring. If aninhibit input occurs during an output, the output remains "on" for the remainder of the OFF-DELAY time.

ON & OFF DELAY: ON and OFF DELAY logic combines both timing functions into a single mode. The ON-DELAY ("DELAY") time and the OFF-DELAY ("HOLD") time are independently adjustable within the selected time range.Momentary grounding of pin #9 during the ON-DELAY period resets the DELAY timer. An inhibit signal which occurs duringan output will allow the output to stay energized for the remainder of the OFF-DELAY time. ON and OFF DELAY logic isoften used in jam and void control, high/low level control, and edge-guiding applications.

ONE-SHOT: The output of a ONE-SHOT function is a pulse of adjustable "HOLD" duration which is independentof the duration of the input signal. With the MAXI-AMP programmed for LIGHT operate, the pulse occurs when the inputsignal changes from dark to light. In DARK operate, the pulse occurs with a light to dark input transition. Grounding pin #9prevents the one-shot from triggering, but does not affect a pulse already under way.

DELAYED ONE-SHOT: A DELAYED ONE-SHOT is initiated by either a momentary or maintained inputsignal. This input starts the adjustable "DELAY" period, after which the output pulses for an adjustable pulse ("HOLD") time.No further action occurs unless the input is removed and reapplied, beginning a new sequence. Grounding pin #9 during thedelay period will cancel the sequence, and no output occurs. This feature is often used for inspection/rejection control logic.An inhibit signal will not affect a pulse under way.

REPEAT CYCLE: The REPEAT CYCLE function provides an oscillating output when an input signal is present.Presence of an input signal triggers an adjustable "DELAY" timer. After the delay, the output energizes for an adjustable"HOLD" period. If the input remains, the output continues to cycle "on" and "off" at this rate indefinitely. When the signalis removed, any output in progress completes and then remains "off" until the next signal and DELAY period. Grounding pin#9 cancels the sequence, but will allow the completion of a "HOLD" period in progress. Lifting the inhibit signal begins theDELAY period, if an input signal is present.

AC LATCH: An AC LATCH is the combination of a ONE-SHOT and a LATCH. A momentary or sustained inputwill latch the output "on". Grounding pin #9 will reset the latch, even if the input signal remains. The output will not re-latchuntil the input signal is removed and then reapplied.

DC LATCH: The output will latch "on" whenever the selected LIGHT or DARK input condition occurs. Groundingpin #9 of a dc latch will turn the output "off" regardless of the state of the input signal. If the signal is present when the resetis removed, the output will immediately latch "on" again.

DELAY AND LATCH: The DELAY + LATCH is a combination of the ON-DELAY and DC LATCH functions.An input must be present for at least the adjustable "DELAY" time for the output to latch "on". If the input signal is removedduring the timing cycle, the timing is reset. Momentary grounding of pin #9 resets the latch and/or the DELAY timing cycle.Sustained grounding of pin #9 inhibits any output.

LIMIT AND LATCH: The LIMIT + LATCH operates exactly like the LIMIT function, except that the LIMIT("HOLD") timer can be reset only by the auxiliary input. An output remains latched "off" until reset by momentarily groundingpin #9. In addition to resetting the timer, grounding pin #9 will hold the output "off", regardless of the state of the input signal.

Description of Logic Functions for CD5, CL5, CM5, and CR5 models

6

Page 7: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

SP12 Series Opposed Mode Remote Modulated Barrel Sensorsfor use with MAXI-AMP CD Series Modules

Model Type Housing Material

SP12SEL

SP12PEL

SP12SRL

SP12PRL

Emitter

Emitter

Receiver

Receiver

Stainless steel

VALOX ®

Stainless steel

VALOX ®

NOTE: Models with 30-foot attached cable are available (contact factoryfor information). 2- and 3-conductor 50- and 100-foot extension cables(without connectors) are also available. For 2-conductor (emitter) cable:order model EC12E-50 (50') or model EC12E-100 (100'). For 3-conductor(receiver) cable: order model EC12R-50 (50') or model EC12R-100 (100').

SP12 Series Barrel Sensors

VALOX ® is a registered trademark of General Electric Co.

10

0

DISTANCE

100

1000

1 FT

SP12 Seriesopposed modeemitters and receivers

10 FT 100 FT 1000FT

EXCESS

GAINI

15ms response

1.5ms response

Beam PatternExcess Gain Curve

400

0

INCHES

OPPOSED DISTANCE--FEET

80 120 160 200

20

40

60

20

40

60

SP12 Series emitters and receivers

1.5ms response

15ms response

Banner SP12 Series sensors are a family of powerful, modulated,totally-encapsulated opposed mode remote sensor pairs in compact,threaded-barrel type housings. They are the ideal choice for applica-tions that require high excess gain together with small size in difficultsensing environments. SP12 Series sensors are especially effective atpenetrating heavy contaminants when used at close range.

The preamplified design of these sensors results in exceptional noiseimmunity. Signals carried along remote receiver cables are oftensubject to interference (from electrical noise sources) that can be asstrong as (or stronger than) the desired light signal. The severity of thisproblem often worsens with increasing sensor cable length. SP12Series receivers contain a preamplifier that immediately boosts thereceived light signal to a high level before sending it down the cable tothe rest of the sensing system.

SP12 Series sensors are designed for use with the Banner CD SeriesMAXI-AMP™ modules. CD Series modules provide sensor power,additional amplification, a choice of several programmable timinglogic functions (CD5 models), and output circuitry for interfacing toa load. They also allow two different programmable sensor modulationfrequencies, making it possible to use multiple high-powered sensorpairs in close proximity to each other without optical crosstalk. CDSeries modules are available for a wide range of supply voltages. EachCD module powers one SP12 emitter/receiver pair. See page 3 for moreinformation.

SP12 sensors are rated NEMA 6P (IEC IP67) for use in wet locations.There is a choice of either VALOX® or stainless steel housing style (seetable, below). Positive sealing at both ends of the sensors, with noexposed epoxy interfaces, eliminates all leak paths (including capillaryleakage). Electronics are fully encapsulated for maximum resistance tomechanical shock and vibration. Lenses are acrylic, and quad-ringsealed. These sensors may be used with watertight, thread-on aper-tures to create very narrow, very powerful effective beams (see nextpage).

A 1/2" clearance hole is required for mounting. Alternatively, theBanner model SMB12MM mounting bracket may be used (see nextpage). SP12 Series sensors are supplied with 6-1/2 feet of PVC-covered attached cable, or QD connectors (page 8). Options for modelswith attached cable are summarized below. The maximum recom-mended emitter or receiver cable length is 100 feet (each).

Leakproof NEMA 6P threaded-barrel opposed moderemote sensor pairs; VALOX® or stainless steel housing

Compact and powerful: 1/2" (12mm) in diameter by 2"long; 200-foot sensing range. Apertures are available.

Special preamplified circuit design for noise immunityequal to that of self-contained sensors

SUPPLY VOLTAGE: sensors are powered from a Banner CD SeriesMAXI-AMP™ module (see page 3).RANGE: up to 200 feet in opposed mode (see gain curve, above).

RESPONSE SPEED: selectable for 1.5 or 15 milliseconds; a functionof the MAXI-AMP CD Series module.

LIGHT BEAM: infrared LED, 880nm. Effective beam diameter: 3/8".

CONSTRUCTION: NEMA 6P.12mm diameter tubular threaded VALOX® or stainless steel housing;positive sealing at both ends, quad-ring sealed acrylic lens. Electronicsfully epoxy-encapsulated. Two jam nuts are provided: VALOX® forVALOX ® units; stainless steel for stainless steel units. Mountingrequires 1/2" diameter clearance hole.OPERATING TEMPERATURE: -40 to +70°C (-40 to +158°F).

CABLE: sensors are supplied with 6-1/2 feet of PVC-covered 2- or 3-conductor cable. Models with QD connectors are available (page 8).

Dimension Drawing

Specifications, SP12 Sensors

SP12 Series sensors (foreground) shown with MAXI-AMP™CD Series amplifier and logicmodules (see pages 3-6).

Models are also available with QD connectors (page 8).

7

MAXI-AMP ™ System

Page 8: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Model SMB12MM Mounting Bracket

Model SMB12MM is a stainless steel mounting bracket for SP12Series sensors. The sensor mounts to the bracket using the two jamnuts supplied with the sensor. This rugged, slotted bracket allows±10 degrees of lateral movement. Bracket is 12-gauge stainlesssteel. The bracket mounting holes accommodate #8 hardware.

Dimensional Information for MQDC-415 Cable Dimensional Information for MQDC-415RA Cable

SP12 Series Opposed Mode Remote Modulated Barrel Sensorswith Quick Disconnect (QD) Cable Option

AperturesRectangular and circular thread-on water-tight apertures are available for SP12sensors. Apertures are used to shape andsize the sensor's effective beam and toprotect the sensor's lens. Use of apertureswith these high-gain sensors makes itpossible to create very narrow, concentrated sensing beams fordemanding applications. Aperture Kit AP12SC includes threeround apertures with openings of .02", .04". and .10" diameter.Aperture kit AP12SR has three rectangular apertures .02", .04",and .10" wide. Both include lens, o-rings, and thread-on housing.

The stainless steel models of SP12 Series modulated remote barrel sensorsmay be ordered with a built-in connector designed to mate with eurofast™quick-disconnect (QD) cables. The resultant sensor model numbers are:

SP12SELQD (emitter), and

SP12SRLQD (receiver).

The mating cables are ordered separately. Cables are available in 15 footlengths with either of two styles of mating connector. Cable model MQDC-415 has a straight connector, and model MQDC-415RA has a right-angledconnector (see drawings below). In both models, the plug body is moldedto the PVC cable for waterproof integrity. Plug contacts are gold-plated.

Dimension Drawing

SMB12MM bracket:

White wire

Blue wire

Black wire

Brown wire

White wire

Blue wire

Black wire

Brown wire

8

Page 9: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

9

3) Power for External Devices (all models)External 10 to 30V dc devices such asself-contained sensors may be connectedbetween terminals #3 (+) and #1 (-) ofany CD series MAXI-AMP module.Terminal #3 offers 40mA maximum.This is sufficient to power most Bannerself-contained dc sensors.

As the example at the right illustrates,the current sinking output of a self-contained sensor powered by the MAXI-AMP may be used as the input to theAUXILIARY terminal of a CD5 mod-ule.

See Hookup Diagram #1 (above) for load and power connection information.

2) Logic Level NPN Output (CD3 models)Typically, the CM5 module wouldbe programmed for the ONE-SHOTor DELAYED ONE-SHOT logicfunction. If the SP12 pair "sees" anacceptable condition when theSP300D senses the leading (or trail-ing) edge of a product, the CD3 willinhibit a reject pulse from occuring.

The AUXILIARY terminal (#9) of models CD3A, CD3B, CD3RA andCD3RB modules offers a logic-level NPN (current sinking) output which maybe used as a fast-response solid-state inhibit signal to the AUXILIARY inputof MAXI-AMP CD5, CL5, CM5, or CR5 Series modules. This output mayalso serve as an input to any MI-CRO-AMP™, Plug Logic, or CLSeries logic module. In addition,this output may interface to other dcdevices or circuits like counters,rate meters, or programmable logiccontrollers. Switching capacity is20mA maximum at 12V dc max.

The example here shows the use ofSP12 Series sensors and a CD3 mod-ule to provide inspection informa-tion, with the SP300D functioningas a product (GATE) sensor.

greenblack

white

green

redblack

white

Gate(Interrogate)

Data(Inspection)

Inhibit

ACSupply

CD3models

87

65

4

910

111

23

ACSupply

CM5models

87

65

4

910

111

23

SP300D

SP12 Series Emitter SP12 Series Receiver

bluebrown

NOTE: Black wire from SE612

is not used +15V dc(#3)

GATE(Interrogate)

CD5models

Inhibit

White

green

blueblack

white

ACSupply

Blue(#1)Brown

+15V dc @40mA

DATA(Inspection)SE612

87

65

4

910

111

23

brown

SP12 Series Emitter SP12 Series Receiver

CD3RACD3RBCD5RACD5RB

SPDT 5ARelay

Output

AC SUPPLY* 8

76

54

910

111

23

CD3ACD3BCD5ACD5B

LED + (white)

LED - (green)

COMMON (black)

PT - (blue)

AUX

87

65

4

910

111

23

AC SUPPLY* PT + (brown)

AC Load

DC Load

Load Common

Models with isolated solid-state contacts

LED + (white)

LED - (green)

COMMON (black)

PT - (blue)

AUX

PT + (brown)

Emitter Receiver

Emitter ReceiverModels with electromechanical relay contacts

*105 to 130V ac or 210 to 250V ac, 50/60Hz, depending on model. To power the MAXI-AMP™ module from a dc supply, connect+12 to 28V dc at ≥70mA to terminal #3 and dc common to terminal #1. Make no connection to terminal #7 or #8.

SP12 Series sensors are especially designed for use with CD Series modules. The basic hookup is given here (QD sensor models shown). Each MAXI-AMP™CD Series module supports use of one pair of SP12 Series sensors. CD5 Series module models also support use of a GATE or INHIBIT sensor at pin #9 (below,this page).

1) Hookup of SP12 Series Sensors (all models)

SP12 Sensor Hookup to CD Series MAXI-AMP™ Modules

Page 10: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

CM Series MAXI-AMPs combine power supply, modulated photo-electric amplifier, timing logic (in CM5 models) and output relay in asingle compact, cost-saving module. CM-series modules work to-gether with the popular family of Banner high-performance modulatedremote sensors (pages 13-17). These sensors offer small size andexcellent optical performance, and are built to operate in highlydemanding sensing environments. MAXI-AMP modules themselvesare also ruggedly built for dependable industrial duty.

CM Series MAXI-AMP modules contain the state-of-the-art Bannercustom-designed CMOS modulator/demodulator/amplifier circuit, of-fering high immunity to both ambient light and electrical interferenceplus reliable sensor performance. All models have Banner's exclusive,patented Alignment Indicating Device ("AID™") system, which lightsan LED indicator whenever the sensor sees a "light" condition, andpulses the LED at a rate proportional to the received light signalstrength.

All CM Series modules are programmable for LIGHT or DARKoperate and either high or low hysteresis. Input response time may beset at 0.3, 2, or 10 milliseconds. The 10-millisecond response modeoffers enhanced immunity to electrical interference ("noise"), and also

minimizes optical "crosstalk" between adjacent sensors. Unlike otheramplifier designs, input response time settings of the CM Seriesmodules do not affect sensor range.

MODEL OUTPUT LOGIC

SPDT electro-mechanical relay(5 amp contactrating)

ON/OFF

12timingfunctions210 to 250V ac, or

12 to 28V dc

105 to 130V ac, or12 to 28V dc

CM3RA

CM3RB

CM5RA

CM5RB

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

SPDT electro-mechanicalrelay, plus NPNtransistor solid-state DC switch

Solid-state Output Option

MODEL OUTPUT LOGIC

CM3A

CM3B

CM5A

CM5B

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

ON/OFF

12timingfunctions210 to 250V ac, or

12 to 28V dc

105 to 130V ac, or12 to 28V dc

SPST solid-statecontact forswitching ACloads up to 250V ac and up to3/4 amp, plussolid-state con-tact for switch-ing DC loads upto 30V dc and upto 50mA.

SUPPLYVOLTAGE

MODEL OUTPUT LOGIC

CR3RA

CR3RB

CR5RA

CR5RB

SPDT electro-mechanical relay(5 amp contactrating)

ON/OFF

12timingfunctions

MAXI-AMP CR Series Modulated Modules for SP100 Series Miniature Remote Sensors

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

SPDT electro-mechanicalrelay, plus NPNtransistor solid-state DC switch

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

SUPPLYVOLTAGE

The amount of amplification available from CM Series MAXI-AMPmodules is too high to operate with the Banner SP100 Series ofminiature modulated remote sensors. CR Series modules correct thisincompatibility with a modified modulated amplifier design. CR Seriesspecifications are exactly the same as for the standard CM Seriesmodels (listed above) except for the difference in amplifier gain.Available models are listed in the table at the right.

SP100 Series sensors are ideal for OEM machinery and for tight spaceswhere the use of photoelectric sensors was previously consideredimpossible. The SP100 Series is described in the Banner catalog.

CR Series modules are also available with the solid-state output option(see above).

SUPPLYVOLTAGE

CM5 models include a versatile multi-function timing logic circuitwhich is programmable for 12 of the most popular and useful delay,one-shot, and latch functions (see page 6). Each timing function has achoice of three time ranges. Timing and sensitivity adjustments areaccomplish-ed via rugged 15-turn potentiometers for very accuratesettings. CM Series circuitry is designed to prevent false outputs onsystem power-up.

An auxiliary input is available on CM5 models for interrogation or resetof the selected logic function (see example, page 17). Page 6 describesthe function of the auxiliary input for each logic mode. A dc powersupply is included for powering an additional self-contained dc sensor.

The output circuit for all CM Series modules is an SPDT 5-amp electro-mechanical relay. Additionally, CM3 models have an NPN transistorsolid-state switch. The output may be programmed for either normallyopen or normally closed operation. A solid-state relay is offered as anoption to the electromechanical relay (see information below).

Recognized Certified

MAXI-AMP ™ CM SeriesModulated Amplifier Modules

10

CM Series modules are available with a solid-state relay which replaces theelectromechanical relay. This is actually two SPST solid-state contacts. Onecontact will switch ac loads. The contact is rated at 250V ac maximum and3/4 amps maximum at 25 degrees C (derated to 1/2 amp at 50 degrees C). Theother solid-state contact will switch dc loads of up to 30V dc and up to 50milliamps. Both contacts are isolated from the MAXI-AMP power supply.

Page 11: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Dimension Drawing

NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dcdevice (see hookup example, page 17). Current available is 40 mA at 120V ac (240Vac) line level; 30mA at 105V ac (210V ac) line level. Alternately, the module maybe powered by 12 to 28V dc at pins #3 (+) and #1 (-). Do not connect ac voltage if usingexternal dc power.NOTE #2: pulling pin #9 low (to common) will inhibit the timing, or reset the latchof CM5 or CR5 models (see "Description of Logic Functions", page 6).

CM5 & CR5 ModelsFunctional Schematics

CM3 & CR3 Models

NOTE #3: pin #9 of CM3 or CR3 models may be connected directly to theAUXILIARY input of a MAXI-AMP or Banner M Series module. It may also serveas the input to Banner CL series MAXI-AMPs or to Banner Plug Logic modules (seehookup example, page 17).

11

SUPPLY VOLTAGE: Models CM3(R)A, CM5(R)A, CR3(R)A, andCR5(R)A: 105 to 130V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA.Models CM3(R)B, CM5(R)B, CR3(R)B, and CR5(R)B: 210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc* at 70mA.*NOTE: do not connect ac power if using external dc power.

OUTPUT CONFIGURATION:Models CM3A, CM3B, CM5A, CM5B, CR3A, CR3B, CR5A, CR5B haveSPST solid-state relay for switching ac or dc (see page 10).

Models CM3RA, CM3RB, CM5RA, CM5RB, CR3RA, CR3RB, CR5RA,CR5RB have SPDT electromechanical (e/m) relay with the following ratings:CONTACT RATING: 250V ac max, 24V dc max, 5 amps max. (resistive load),1/10 H.P. at 240V ac. Install transient suppressor (MOV) across contacts whichswitch inductive loads.CONTACT RESPONSE: 10 milliseconds max. open/close;20 operations/second max.MECHANICAL LIFE: 20,000,000 operationsCM3 and CR3 models also have a logic level current sinking NPN transistorswitch at pin #9. See schematic (right) and hookup info.

AMPLIFIER:RESPONSE SPEED: programmable for 10, 2, or 0.3 milliseconds. NOTE: use10 millisecond setting whenever possible for enhanced noise rejection.HYSTERESIS: if programmed "HIGH", approximately 20%; if programmed"LOW", approximately 5%. NOTE: see cautions for "LOW" setting, page 12.MODULATION FREQUENCY: approximately 10kHz.

SENSOR LEAD LENGTH: 50 feet (15 m) maximum. Use separateshielded cable for emitter and receiver, or order sensors with extended cablelength. NOTE: see splicing precautions, page 17.

MULTIPLE SENSOR HOOKUP: Up to three sensors may be wiredtogether to one CM-series amplifier for "OR" operation (in LIGHT operate) or"NAND" operation (in DARK operate). Emitters are connected in series, andreceivers are connected in parallel. When wiring two sensors to one MAXI-AMP, multiply excess gain data for each sensor by 1/2 (obtain data fromapplicable excess gain curve). When wiring three sensors to one MAXI-AMP,multiply excess gain by 1/3.

TIMERS (CM5 models only):TIMING RANGES: LOW range - 10 to 150 milliseconds

MIDDLE range - 0.1 to 1.5 seconds HIGH range - 1 to 15 seconds

REPEATABILITY: +/-2% of set time over all extremes of supply voltage and temperature

ADJUSTMENTS: Miniature switches for programming of LIGHT/ DARKoperate, amplifier response time, amplifier hysteresis, normally open or nor-mally closed output, and timing function (CM5 & CR5 models). 15-turnclutched potentiometer for gain and time setting(s) (CM5 and CR5 models).

OPERATING TEMPERATURE: 0 to 50°C (32 to 122°F).

INDICATOR LEDs: Red indicator LED is "ON" when the module outputis energized. Exclusive Banner Alignment Indicating Device (AID™) systemlights a red LED indicator whenever the receiver "sees" its own modulated lightsource, and pulses it at a rate which is proportional to the strength of the receivedlight signal.

CONSTRUCTION: Rugged NORYL® polyphenylene oxide (PPO®) hous-ing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plug base.

NOTE: If MAXI-AMP is powered by a dc power supply, connect +12 to 28V dc@ ≥70mA to terminal #3 and dc common to terminal #1.Make no connections to terminal #7 or #8.

Generalized Hookupmodels with electromechanical relay output

MAXI-AMP CM and CR Series Specifications

Page 12: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Settings illustrated below are factory settings. Factory settings are "underlined" in the table.

Factory settings shown atleft. "Underlined" settingsin table below are factorysettings.

Timing Logic Programming (CM5 and CR5 models)

The diagram shows switch locations, and thetable summarizes the program switchpositions.

A group of ten switches, located on the side of the module opposite the amplifier programswitches, is used to select the timing logic for the CM5 and CR5 models.

Switches #1 through #7 are used to select the logic function. Switch #8 programs the outputfor either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds,and 1 to 15 seconds. The programmed range will be the same for both functions of a dualtiming mode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE).However, DELAY and HOLD times are independently adjustable within the selected range.

12

The diagram at the left shows the location of switches 1-4,and the table summarizes the settings required for eachresponse condition.

NOTE: an adhesive-backed mylar label is supplied, whichmay be marked to indicate switch programming and thenapplied to the MAXI-AMP housing as a switch cover.

Amplifier response conditions may be programmed via the group of fourswitches located on one of the narrow sides of the MAXI-AMP module.

Switch #1 selects the amount of amplifier hysteresis. Hysteresis is theamount of signal change beyond the switching threshold which isrequired to cause the amplifier output to change state, and is expressedas a percent of amplifier gain. The NORMAL setting of 20% shouldalways be used, except for low contrast situations such as many colorregistration applications.

NOTE: the LOW hysteresis setting should be used only when allsensing conditions remain stable. "Buzzing" of the output (in ON/OFF and LIMIT operation) or false outputs (in DELAY, ONE-SHOT, or LATCH operation) may occur if sensing variables (e.g.-web flutter) result in optical contrast approaching unity.

Switches #2 and #3 are used to program the amplifier response time.The 10 millisecond setting should be used whenever possible for thegreatest immunity to electrical interference ("noise"). The 2 millisec-ond setting has more interference rejection than the 0.3 millisecondmode. Sensor performance (excess gain) is identical in all threeresponse settings.

Amplifier Programming (all models)

Switch #4 is used to select LIGHT OPERATE or DARKOPERATE. In the LIGHT OPERATE mode, the output willenergize (in ON/OFF or LATCH operation) or the timingfunction will initiate (in DELAY, ONE-SHOT, or LIMIToperation) when the receiver "sees" sufficient light (excessgain greater than 1X). In DARK OPERATE, the output willenergize or timing will begin when the receiver is suffi-ciently dark (excess gain less than 1X).

ON

ON

ONOFF

AMPLIFIER

PROGRAMMING #1 #2 #3 #4SWITCH SWITCH SWITCH SWITCH

ON

OFF

1

2

3

4

Normal hysteresis (20%)

Low hysteresis (5%)

10 millisecond response

2 millisecond response

0.3 millisecond response

Light operate

Dark operate

ON

ONON

OFF

OFF

OFF

ON

OFFON

ON ON ON OFF ON OFF ON

PROGRAMMINGTIMING LOGIC

#1 #2 #3 #4 #5 #6 #7 #8 #9 #10

10

ON

OFF

1

2

3

4

5

6

7

8

9

SWITCH SWITCH SWITCH SWITCH

ON

ON

ONON

OFF

OFF

OFF

SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH

On/Off

On Delay

Off Delay

On and Off Delay

One-shot

Delayed One-shot

Limit

Repeat Cycle

AC Latch

DC Latch

Delay and Latch

Limit and Latch

ON ON OFF ON OFF ON

OFF OFFOFF OFF ON

ONOFFOFF OFF ON OFF ON

OFF OFFOFF OFF OFF

ON ON ONOFFOFF OFFOFF

OFF ON ON OFF ON

OFF ON ON OFF

ON

ONONON

ONON OFF ONONON

ON ON OFF OFF ONONON

ON ON OFF OFF OFF ONON

N/C Output

N/O Output

.15 Sec. Max. Time

1.5 Sec. Max. Time

15 Sec. Max. Time

OFF

OFF OFF

OFF ON

ON OFF ON OFF ON OFF ON

Page 13: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Beam Pattern

LR/PT200, 250, 300, and 400 opposed mode remote sensors areidentical electronically and optically, and differ only in their housings.All are totally epoxy-encapsulated and use hermetically sealed glasslenses to eliminate condensation inside the optical chamber. Thesesensors may be washed down without damage. Operating temperatureis determined by the type of cable used (see specifications above).These sensor pairs feature wide beam angle for forgiving line-of-sightalignment. At the same time, the effective beam of each pair is only1/8 inch, allowing small-profile resolution and reliable response to fast-moving objects. LR models are emitters; PT models are receivers.

LR200 & PT200: this is a right-angle design which mounts through a7/16 inch (12mm) diameter hole, using the steel jam nut which isincluded. This pair is used most commonly on small conveyors whenit is desireable to run the cable directly down to a wireway.

LR250 & PT250: these sensors feature a 1/4 inch (6,4mm) diametersmooth barrel design, and are usually held in place in a clearance holewith a small set-screw. Optional mounting blocks (shown below) areavailable. Model SMB250 holds the sensor in place with two set-screws. The block is then mounted to a bracket (like model SMB300,page 15), or directly to a machine frame with two #6 screws. Blockmodel SMB250C holds an LR & PT250 together to converge atapproximately 1/2 inch ahead of the block.

SMB250 SMB250C

LR200 & PT200 LR250 & PT250 LR300 & PT300 LR400 & PT400Temp. range: -40 to +100 degrees CHousing material: black Delrin®

Temp. range: -40 to +100 degrees CHousing material: black Delrin®

Temp. range: -40 to +80 degrees CHousing material: black VALOX®

Temp. range: -40 to +100 degrees CHousing material: anodized alum.

AP400 apertures

OPPOSED Mode

L4 lens L16 lens

The LR/PT400 pair is often used at close range with optional AP400 apertureassemblies to create a very small and well-defined effective beam for resolvingsmall profiles, increasing sensing repeatability, or easing response time require-ments.

10

1

DISTANCE

100

1000

.1 FT 1 FT 10 FT 100 FT

EXCESS

GAINI

LR/PT200, 250, 300, & 400

20

0

INCHES

OPPOSED DISTANCE--FEET

4 6 8 10

4

8

12

4

8

12

LR/PT200, 250, 300, 400

MAXI-AMP System

LR & PT300: this is a miniature right-angle design which is mountedin place using two #4 screws. This pair uses a very flexible, low-profile2-wire cable. Despite their small size, the optical performance of theLR/PT300 is equal to the other remote sensor pairs.

LR400 & PT400: the 3/8 inch (9,5mm) diameter threaded barreldesign makes the LR/PT400 the most versatile and most popular remoteopposed sensor pair. They are easily mounted through clearance holesusing the jam nuts which are supplied. They may be used with optionalL4 or L16 lenses for extended range and/or higher excess gain. Theaddition of an L4 lens on both the LR and PT400 will increase theirrange from 8 feet to 40 feet and increase the excess gain at any distanceby a factor of 25X. A pair of L16 lenses will increase available excessgain by a factor of 250X.

ALL MODELS:Range: 8 feet (2,4m)Beam: infrared, 880nmEffective Beam: .14 inch (3,6mm) dia.

LR models are emittersPT models are receivers

Sensors for use with CM Series Modulated AmplifiersSensors are epoxy-encapsulated and optics are hermetically sealed. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order.Sensor accessories are shown on page 24.

Aperture size.010" dia..015" dia..040" dia..030" x .125"

Aperture modelAP400-010AP400-015AP400-040AP400-030R

Excess GainModels/Dimensions

13

Page 14: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

NOTE: for complete information on retro-reflective materials, see Banner catalog.

Range: 15 feet (4,5m) with BRT-3retroreflectorTemp. range: -40 to +80 degrees CHousing material: blue anodizedaluminum

Sensors are epoxy-encapsulated. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order.Sensor accessories are shown on page 24.

Sensors for use with CM Series Modulated Amplifiers

Models/Dimensions Excess Gain

forgiving for reflectively sensing transparent or translucent materials or forsensing objects with irregular surfaces (e.g.- webs with "flutter"). The optics aresuch that even small threads or wires .005" (0,1mm) or greater in diameter may bedetected when they pass within .25" (6mm) of the sensor's plastic lens. Due to itswide response pattern, the LP400WB should not be used for precise positioningcontrol, nor should it be mounted with its lens recessed into a hole.

"WB" in this model number designates "wide beam". The LP400WB is aninfrared divergent mode (wide angle diffuse mode) sensor which is particularly

100

0

INCHES

30 40 50

6

OPPOSED DISTANCE --FEET

12

18

6

12

18

20

SP300EL/RL

40

0

INCHES

8 12 15 18

2

DISTANCE TO REFLECTOR--FEET

4

6

2

4

6

with BRT-3 reflector

SP300L

10

INCHES

2 3 4 5

.5

DISTANCE TO 90% WHITE TEST CARD--INCHES

1.0

1.5

.5

1.0

1.5

LP400WB

0

10

1

DISTANCE

100

1000

.1 FT 1 FT 10 FT 100 FT

EXCESS

GAINI

SP300EL/RL

10

1

DISTANCE

100

1000

.1 FT 1 FT 10 FT 100 FT

withBRT-T tape

withBRT-1 target

withBRT-3 target

SP300LEXCESS

GAINI

100

10

1.1 IN 1 IN 10 IN 100 IN

1000

LP400WBRange based on 90% reflectancewhite test card

DISTANCE

EXCESS

GAINI

SP300L

SP300EL & SP300RL

MAXI-AMP System

RETROREFLECTIVEMode

DIVERGENTMode

Range: 50 feet (15m)Effective Beam: .5 inch (13mm) dia.Temp. range: -40 to +100 degrees CHousing material: anodized aluminum

Long RangeOPPOSED Mode

LP400WBRange: 3 inches (76mm)Temp. range: -40 to +80 degrees CHousing material: blue anodizedaluminum

Beam Pattern

Model SP300L is a remote retroreflective sensor with the same rugged designas the SP300EL/RL, described above. Its useable range is from 6 inches to 15feet (0,2 to 4,5m) using the model BRT-3 retroreflector.

Emitter-receiver pair SP300EL/RL are extremely rugged and are totally encap-sulated in anodized aluminum housings. The threaded hub at the cable exitallows for the use of flexible armored cable or protective PVC tubing with theaddition of compression gland model CF7-16 (page 24). This pair uses

14

collimating lenses to increase range. These sensors should also be used at shortranges for their high excess gain or to avoid optical "crosstalk" in situations whichrequire several pairs to be mounted adjacent to one another.

If the object that is to break the beam has a shiny surface, then the SP300L and itsretroreflector should be mounted so that the beam is at an angle of 10 degrees ormore to that surface in order to eliminate false signals which are caused by proxing.

Page 15: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

SP1000V CONVERGENT ModeRange: focus at 3.8 inches (96mm)Temp. range: -40 to +80 degrees CHousing material: black anodizedaluminum

SMB300UNIVERSAL MOUNTINGBRACKET forSP300 Sensors

SP300D: the SP300D is the diffuse mode version of the SP300L with thesame rugged aluminum housing and totally encapsulated construction. Theglass lenses are hermetically sealed, which eliminates any possibility ofcondensation inside the lenses and allows operation in adverse environ-ments like steam washdown and high vibration. The SP300D may bemounted by its through-holes or with the SMB300 bracket, as shown below.

SP320D: model SP320D is identical to the SP300D, except for its housing.The 320 is a miniature plastic package, designed to fit into very tightlocations. It mounts using two #4 (3mm) screws. The SP320D and theSP300D are excellent for nearly any presence sensing application.

SP300DRange: 12 inches (30cm)Temp. range: -40 to +80 degrees CHousing material: green anodizedaluminum

SP320D DIFFUSEModeRange: 12 inches (30cm)

Temp. range: -40 to +80 degrees CHousing material: black VALOX®

Models/Dimensions

Sensors are epoxy-encapsulated. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order.Sensor accessories are shown on page 24.

Sensors for use with CM Series Modulated amplifiers

Excess Gain

MAXI-AMP System

Beam Pattern

Accessory bracket model SMB300 is designed for 2-axis universal mount-ing of sensor models SP300EL, SP300RL, SP300L, and SP300D. Thesesensors are affixed to the SMB300 with two #6 (3,5mm) screws. Thebracket, in turn, mounts with two #10 (5mm) screws.

In addition, as indicated by the dimension drawing, the SMB300 has aclearance slot for mounting LR400, PT400, and LP400WB barrel sensors.LR & PT200 sensors may be mounted with the SMB300, using its 7/16-20threaded hole and steel jam nut, which is supplied with the sensors. LR250and PT250 sensors may be used with the SMB300 when the SMB250 blockis used (see page 13). Also, two SMB250 blocks may be attached to theSMB300 bracket and angled to mechanically converge an LR & PT250sensor pair.

The SP1000V is a convergent mode sensor that produces a very small 0.1inch (2,5mm) diameter sensing image at a point exactly 3.8 inches (96mm)from its glass lenses. As the excess gain curve illustrates, the SP1000V hasa very sharp drop-off of gain beyond the focus point. This feature makes itan excellent choice for detecting a small part which is only a fraction of aninch in front of another surface, such as parts on a conveyor (viewed fromabove). It is also ideal for fill level detection and for precise positioningcontrol, in lieu of opposed sensing.

10

1

DISTANCE

100

1000

.1 IN 1 IN 10 IN 100 IN

SP300D, SP320DEXCESS

GAINI

10

1

DISTANCE

100

1000

.1 IN 1 IN 10 IN 100 IN

SP1000VEXCESS

GAINI

30

0

INCHES

6 9 12 15

.2

DISTANCE TO 90% WHITE TEST CARD--INCHES

.4

.6

.2

.4

.6

SP300D, 320D

10

0

INCHES

2 3 5 4

.030

.060

.090

.090

.060

.030

DISTANCE TO 90% WHITE TEST CARD--INCHES

SP1000V

15

Page 16: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

FIBER OPTIC Mode glass fiber optics

Range: see excess gain curvesTemp. range: -40 to +100 degrees C

Fiber optic information:IT13S: individual assembly.06 in. (1,5mm) dia. bundleIT23S: individual assembly.12 in. (3mm) dia. bundleBT13S:bifurcated assembly.06 in. (1,5mm) dia. bundleBT23S:bifurcated assembly.12 in. (3mm) dia. bundleL9: .5 in. (12mm) dia. lensL16F: 1.0 in. (25mm) dia.lens

Models/Dimensions

Sensors are epoxy-encapsulated and optics are hermetically sealed. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order.Sensor accessories are shown on page 24.

FOF-400 Fiber optic Fitting

Hookup of LR/PT200, 250, 300, and 400

60

0

INCHES

30

1

2

3

1

2

3

2412 18OPPOSED DISTANCE--INCHES

Opposed mode

w/IT13S fibers

w/IT23S fibers

LR/PT400

150

0

INCHES

OPPOSED DISTANCE--FEET

30 45 75

8

16

24

8

16

24

60

Opposed mode

IT23S fibers andL16F lenses

LR/PT400

IT23S fibers andL9 lenses

50

0

INCHES

25

3

6

9

3

6

9

2010 15

w/L9 lens

w/L16F lens

DISTANCE TO REFLECTOR--FEET

Retroreflective mode,with BRT-3 reflector andBT13S fiber

LR/PT400

10

0

INCHES

5 4 2 3DISTANCE TO 90% WHITE TEST CARD--INCHES

Diffuse mode

w/BT13S fibers

w/BT23S fibers0.2

0.4

0.6

0.6

0.4

0.2

LR/PT400

10

1

DISTANCE

100

1000

.1 IN 1 IN 10 IN 100 IN

Diffuse mode -- range based on 90% reflectance white test card

with BP13Sfibers

with BT23Sfibers

EXCESS

GAINI

LR/PT400

Beam PatternExcess Gain

10

1

DISTANCE

100

1000

.1 IN 1 IN 10 IN 100 IN

with IT23Sfibers

with IT13Sfibers

Opposed mode,no lenses

EXCESS

GAINI

LR/PT400

10

1

DISTANCE

100

1000

.1 FT 1 FT 10 FT 100 FT

Retroreflective mode, with BT13S fibers

with L16F lensand BRT-3 reflector

with L9 lensand BRT-3 reflector

EXCESS

GAINI

LR/PT400

10

1

DISTANCE

100

1000

.1 FT 1 FT 10 FT 100 FT

Opposed mode, with IT23S fibers

with L16F lenses

with L9 lenses

EXCESS

GAINI

LR/PT400

MAXI-AMP SystemSensors for use with CM Series Modulated Amplifiers

16

LR400 & PT400with FOF-400 fittings andfiber optics

For complete information on glassfiber optic assemblies and acces-sories, see Banner product catalog.

Hookup to CM Series MAXI-AMP ModulesThe hookup diagrams on this page and thenext include all of the remote sensors for usewith CM Series modulated amplifier mod-ules. It is important to note how the shield wireof a remote sensor is wired. The shield wire is theuninsulated wire in each sensor cable. Failure toconnect the shield as shown may result in falseoperation of the amplifier. When wiring emit-ters, it is good practice to connect the positive(white) wire first. LEDs are sensitive to applica-tion of the wrong voltage, and can easily bedestroyed.

NOTE: up to three sensors may be connected toeach amplifier (see specifications).

The threaded barrel design of theLR400 and PT400 (see page 14) per-mit the connection of any Bannerglass fiber optic assembly by usingtwo model FOF-400 fittings. Thesensors are typically mountedthrough 3/8 inch (10mm) diameterclearance holes, with the FOF-400fittings threaded onto them aftermounting. Setscrews in the fittingslock the fibers in place, but allowrapid replacement without disturb-ing any electrical wiring.

As the excess gain curves show, theLR/PT400 combination produces ahigh-performance fiber optic sens-ing system. With the amplifier's 1millisecond response time, this sys-tem can be used for almost any fiber-optic requirement.

Page 17: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Sensor Hookup Diagrams for CM Series MAXI-AMP Modules

NOTE REGARDING CABLE SPLICING:When splicing additional cable length to modulated remote sensors,it is important to use a separate shielded cable for emitter andreceiver wires. Combining emitter and receiver wires together inthe same cable (even if the cable is shielded) will result in directcoupling of the emitter signal to the receiver leads. This is called"cable crosstalk", and will not allow full amplifier sensitivity settingwithout an amplifier "lock on" situation, which appears as a continu-ous LIGHT condition. Banner offers extension cable for remotesensors which, if used for cable splicing, will minimize the chancesfor cable crosstalk (see page 24).

The AUXILIARY terminal (#9) of CM3 models offers alogic-level NPN (current sinking) output which may be usedas a fast-response solid-state inhibit signal to the AUXIL-IARY input of MAXI-AMP CM5 modules. This output mayalso serve as an input to any B Series, Plug Logic, or CLSeries module. In addition, this output may interface toother dc devices or circuits like counters, rate meters, orprogrammable logic controllers. Switching capacity is20mA at 12V dc.

The example here shows the use of LR & PT400 sensors anda CM3 module to provide inspection information, with theSP300D functioning as a product sensor. Typically, theCM5 module would be programmed for the ONE-SHOT orDELAYED ONE-SHOT logic function. If the LR & PT400"sees" an acceptable condition when the SP300D senses theleading (or trailing) edge of a product, the CM3 will inhibita reject pulse from occuring.

External 10 to 30V dc devices such as self-contained sensorsmay be connected between terminals #3 (+) and #1 (-) of anyCM series MAXI-AMP module. Terminal #3 offers 40mAmaximum. This is sufficient to power most Banner self-contained dc sensors.

As the example at the right illustrates, the current sinkingoutput of a self-contained sensor powered by the MAXI-AMP may be used as the input to the AUXILIARY terminalof a CM5 module.

CM3Model

CM5Model

CM5Model

17

Logic Level NPN Output (CM3 models)

Power for External Devices

Hookup of SP320D

Hookup of LR300 and PT300 Hookup of SP300D, SP300L, LP400WB,and SP1000V

Page 18: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

MODEL OUTPUT LOGIC

CL3RA

CL3RB

CL5RA

CL5RB

SPDT electro-mechanicalrelay, plus NPNtransistor solid-state switch

SPDT electro-mechanical relay(5 amp contactrating)

ON/OFF

12timingfunctions

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

CL Series modules are available with a solid-state relay which replacesthe electromechanical relay. This is actually two SPST solid-statecontacts. One contact will switch ac loads, and is rated at 250V acmaximum and 3/4 amps maximum at 25 degrees C (derated to 1/2 ampat 50 degrees C). A solid-state contact is particularly helpful whenswitching inductive ac loads which can cause electrical "noise" andcontact damage when switched with a "hard" relay contact.

The other solid-state contact will switch dc loads of up to 30V dc andup to 50 milliamps. Both solid-state outputs are electrically isolatedfrom the MAXI-AMP power supply. Both outputs switch within the 1millisecond response time of the CL module circuitry. NOTE: ac loadsmay take up to 1/2 cycle (8.3 milliseconds) to turn "off".

Both outputs are normally open, but may be programmed for normallyclosed operation.

Except for the output configuration, the specifications for the modelslisted in the table at the right are exactly the same as for the standard CLSeries models.

Solid-state Output Option

SUPPLYVOLTAGE

210 to 250V ac, or12 to 28V dc

105 to 130V ac, or12 to 28V dc

MAXI-AMP ™ CL SeriesLogic-level Input Modules Recognized Certified

18

Banner CL Series MAXI-AMP™ modules are the perfect solution formany sensing/control applications where economy, versatility, de-pendability, and ruggedness are important. CL Series MAXI-AMPscombine power supply, timing logic (in CL5 models) and output relayin a single compact, cost-saving module. The integrated, stand-alonedesign saves both the expense of a separate control chassis and asubstantial amount of panel space. Several models are available, foreither 120V ac or 240V ac operation, and either with or without timinglogic (models are listed in table at above right). Alternatively, anymodel may be powered by 12 to 28V dc.

The well-defined electrical characteristics of CL Series MAXI-AMPmodules provide a wealth of application possibilities. The inputcircuit accepts signals from any Banner dc sensor with an NPN(current sinking) output; as well as from MAXI-AMP, MICRO-AMP,and Plug Logic modules. The input is compatible with almost anysensor or circuit which has an NPN transistor (current sinking) output.Additionally, inputs may be generated by limit switches, contactclosures, and optical couplers. A 50mA power supply is included forpowering 10 to 30V dc devices.

CL5 models offer a versatile multi-function timing logic circuit whichis programmable for twelve of the most popular and useful delay, one-shot, and latch functions (see page 6). The MAXI-AMP offers thechoice of either single or dual timing functions in the same module.Logic and timing may be easily reprogrammed as control require-ments change.

In order to allow accurate timing adjustments, each CL5 model hasthree time ranges to choose from. Timing adjustments are made viarugged 15-turn potentiometers. Circuitry is included to prevent anypossibility of false output on power-up.

An auxiliary input is available on CL5 models for interrogation orreset of the selected logic function by using an additional sensor orinput signal (see example, page 20). Page 6 describes the function ofthe auxiliary input for each logic mode.

The output circuit for all CL Series modules is an SPDT 5-amp electro-mechanical relay. A solid-state relay is offered as an option to theelectromechanical relay (see information below).

Additionally, CL3 models have an NPN transistor solid-state switch.This solid-state output may be used to take advantage of the amplifier'sfast 1-millisecond response. This output may be connected directly tothe primary or auxiliary input of other Banner logic modules, includ-ing CL5 modules, MICRO-AMP logic modules, and Plug Logicmodules. In addition, this output can interface to other dc devices orcircuits such as counters, rate meters, or programmable controllers.Switching capacity is 20mA at 12V dc. The output may be pro-grammed for either normally open or normally closed operation.

Like all MAXI-AMPs, the CL Series modules are designed bothelectrically and mechanically for solid dependability in industrialenvironments.

MODEL OUTPUT LOGIC

ON/OFF

12timingfunctions

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

CL3A

CL3B

CL5A

CL5B

SPST solid-statecontact forswitching ACloads up to 250Vac and up to 3/4amp, plus solid-state contact forswitching dcloads up to 30Vdc and up to50mA.

105 to 130V ac, or12 to 28V dc

210 to 250V ac, or12 to 28V dc

SUPPLYVOLTAGE

Page 19: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

19

NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device(see hookup example). Current available is 50mA at 120V ac (240V ac) line level; 40mAat 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28Vdc at pins #3 (+) and #1 (-). Do not connect ac voltage if using external dc power.

NOTE #2: pulling pin #9 low (to Common) will inhibit the timing, or reset the latchof CL5 models. (See "Description of Logic Functions", page 6)NOTE #3: pin #9 of model CL3RA and CL3RB may be connected directly to theprimary or auxiliary input of MAXI-AMP model CL5 or to Banner Plug Logicmodules.

SUPPLY VOLTAGE: Models CL3RA, CL5RA: 105 to 130V ac,50/60Hz (4 VA), or 12 to 28V dc* at 60mA. Models CL3RB, CL5RB:210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc at 60mA. *Do notconnect ac voltage if using external dc power.

OUTPUT CONFIGURATION: all models have SPDT electro-mechanical relay:CONTACT RATING: 250V ac max, 24V dc max, 5 amps max.(resistive load), 1/10 H.P. at 240V ac. Install transient suppressor(MOV) across contacts which switch inductive loads.CLOSURE TIME: 10 milliseconds max.RELEASE TIME: 10 milliseconds max.MAXIMUM SWITCHING SPEED: 20 operations/secondMECHANICAL LIFE: 20,000,000 operationsCL3 models also have a logic level current sinking NPN transistorswitch at pin #9. See schematic below and hookup info.

AMPLIFIER:RESPONSE SPEED: 1 millisecondINPUT CHARACTERISTICS: input is switched when the voltage atpin #2 is pulled below 1V dc or when less than 1K ohms is connectedbetween pins #2 and #1. When an inverting jumper is connectedbetween pins #10 and #11, input is switched when the voltage at pin #2rises above 4.5V dc or when the impedance between pins #2 and #1exceeds 15K ohms.HYSTERESIS: greater than .35 volts, less than 2 volts.

MULTIPLE SENSOR HOOKUP: any number of switched outputdevices may be connected in parallel to the input (see hookup example).

TIMERS (CL5 models only):TIME RANGES: LOW range - 10 to 150 milliseconds

MIDDLE range - 0.1 to 1.5 seconds HIGH range - 1 to 15 seconds

REPEATABILITY: +/-2% of set time over all extremes of supply voltage and temperature

ADJUSTMENTS: Miniature switches for setting of timing function,timing range, and output polarity (CL5 models). 15-turn clutchedpotentiometer for time setting (CL5 models).

MAXI-AMP CL Series SpecificationsINDICATOR LEDs: Red indicator LEDs for input and outputstatus.

CONSTRUCTION: Rugged NORYL® polyphenylene oxide(PPO® ) housing, 1.6" x 2.3" x 4". Standard round-pin 11-pole plugbase.

OPERATING TEMPERATURE: 0 to 50 degrees C (32 to 122degrees F).

Generalized Hookupmodels with electromechanical relay output

Functional Schematics

Dimension Drawing

CL5 Models CL3 Models

Page 20: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

SM912

WHITE

BROWN

BLUE

NOTE: Black wire is not used

CL3 or CL5model8

76

54

910

111

23

CL3 or CL5model8

76

54

910

111

23

MAXI-BEAM

4321

RPBT

PBT

1 2

3 4

MULTI-BEAM

CL3 or CL5model8

76

54

910

111

23

Sensor Hookup Diagrams for CL Series MAXI-AMP Modules

NOTE: the MAXI-AMP cannot power a MULTI-BEAM emitter and receiver pair.Use a separate power source for the emitter (e.g.- power block PBA-1, etc.)

CL5 model MAXI-AMPs have an auxiliary input at terminal #9which may be used for the interrogation or reset of the selectedlogic function. This is accomplished by a switch closure betweenpins #9 and #1 (Common). The auxiliary input may also beswitched by a DC device with an NPN transistor (current sinking)output. The effect of the auxiliary input is described for each logicfunction on page 6.

This example shows a typical inspection/rejection scheme whichuses a Banner MINI-BEAM as the inspection sensor. Typically,the CL5 module would be programmed for the ONE-SHOT orDELAYED ONE-SHOT logic function. If the SM312 "sees" anacceptable condition when the SE612 senses the leading (ortrailing) edge of the product, the SM312 will inhibit a reject pulsefrom occuring. Reject products will be ejected by the output pulse.

NOTE: the MAXI-AMP can supply 50mA for external 10 to 30Vdc devices. Carefully check the current draw of the devices to bepowered by the MAXI-AMP.

Use of Auxiliary Input (CL5 models)

NOTE: use power block model RPBT.

To MAXI-BEAM Sensors

To MINI-BEAM SM312 Series Sensors

To ECONO-BEAM SE612 Series Sensors

To MULTI-BEAM Sensors

To VALU-BEAM SM912 Series Sensors

NOTE: Black wire is not used

SM312

BROWN

BLUE

WHITE CL3 or CL5model8

76

54

910

111

23

NOTE: Black wire is not used SE612

WHITE

BROWN

BLUE

CL3 or CL5model8

76

54

910

111

23

+V dc @50ma

NOTE: Black wire is not used

+V dc(#3)

NOTE: Black wire is not used

White

DATA(Inspection)

GATE(Interrogate)

Brown

SE61R

Inhibit

BlueWhite

Brown

SM312

SE61E

Blue(#1)

Brown

Blue(#1)

+15V dc(#3)

CL3 or CL5model8

76

54

910

111

23

NOTE: use power block model PBTor PBT2.

20

To EZ-BEAM Sensors

NOTE: White wire is not used

This hookup is for DC NPN (currentsinking) models of S18 Series,Q25 Series, and other DC sensorsbearing the EZ-BEAM logo.

BROWN

BLUE

BLACK CL3 or CL5model8

76

54

910

111

23

Page 21: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

LIGHT OPERATE

DARK OPERATE

DARK OPERATE

If any receiver "sees"light

When all receivers"see" dark

OUTPUT OCCURS(AFTER DELAY, IFANY)

If any receiver "sees"dark

When all receivers"see" light

NO

NO

YES

(NOTE: see page 6 fordescription of logic functions)

YES

LIGHT OPERATE

INVERTING JUMPERInstalled Between ModuleTerminals #10 and #11

SENSOR PROGRAM:Light or Dark Operate LOGIC DESCRIPTION

The diagram shows switch locations,and the table summarizes the programswitch positions.

Hookup of Multiple Self-contained SensorsAny number of self-contained dc sensors may be wired to-gether in parallel to a single CL Series MAXI-AMP module tocreate almost any multiple-sensor logic configuration. Powerfor the sensors may be obtained from MAXI-AMP 400mApower supply CP12 (shown below) or from 1-amp modelPS120-15. The table at the right describes how the four mostfrequently used multiple-sensor logic configurations may becreated.

MINI-BEAM SM312 Series and VALU-BEAM SM912 Se-ries sensors have a switch on the back of their housings whichis used to program the sensors for LIGHT or DARK operate.MAXI-BEAM sensors are set for LIGHT or DARK operateusing the programming ring. MULTI-BEAM sensors areprogrammed for LIGHT or DARK operate with the logicmodule jumper wire. OMNI-BEAMs are programmed by aswitch in the sensor block.

For ON/OFF sensor operation, light operate is equated tonormally open output, and dark operate is defined asnormally closed. EZ-BEAM sensors have both a normallyopen and a normally closed output. Selection of either outputdetermines the LIGHT/DARK operate mode. ECONO-BEAMsensors are not programmable and must be ordered for LIGHTOPERATE (standard models) or DARK OPERATE (modelsuffix "NC").

The addition of a jumper wire between MAXI-AMP terminals#10 and #11 changes the input response from a low-going toa high-going signal. This feature, combined with the selectionof LIGHT or DARK operate at the sensor, allows "AND" logicwith parallel sensor connections.

Timing Logic Programming (CL5 models)Settings illustrated below are factory settings. Factory settings are "underlined" in the table.

A group of ten switches located on one side of the module is used to select the timing logic forCL5 models.

Switches #1 through #7 are used to select the logic function. Switch #8 programs the outputfor either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds,and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timingmode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However,DELAY and HOLD times are independently adjustable within the selected range.

21

LIGHT "OR"

DARK "AND"

DARK "OR"

LIGHT "AND"

105-130V ac

Brown+V dc

Brown+V dc

Blue(#1)

White

+V dc

Brown

105-130V AC

Blue(#1)

SM31R/RL

White

SM31R/RL SM31E/EL Blue(#1)

Brown+V dc

Blue SM31R/RL

White

CL3 or CL5model

87

65

4 CP12power supply87

65

4

910

111

23

SM31E/EL Blue(#1)

Brown+V dc

SM31E/EL Blue(#1)

Brown+V dc

910

111

23

ON

OFFON

ON ON ON OFF ON OFF ON

PROGRAMMINGTIMING LOGIC

#1 #2 #3 #4 #5 #6 #7 #8 #9 #10

10

ON

OFF

1

2

3

4

5

6

7

8

9

SWITCH SWITCH SWITCH SWITCH

ON

ON

ONON

OFF

OFF

OFF

SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH

On/Off

On Delay

Off Delay

On and Off Delay

One-shot

Delayed One-shot

Limit

Repeat Cycle

AC Latch

DC Latch

Delay and Latch

Limit and Latch

ON ON OFF ON OFF ON

OFF OFFOFF OFF ON

ONOFFOFF OFF ON OFF ON

OFF OFFOFF OFF OFF

ON ON ONOFFOFF OFFOFF

OFF ON ON OFF ON

OFF ON ON OFF

ON

ONONON

ONON OFF ONONON

ON ON OFF OFF ONONON

ON ON OFF OFF OFF ONON

N/C Output

N/O Output

.15 Sec. Max. Time

1.5 Sec. Max. Time

15 Sec. Max. Time

OFF

OFF OFF

OFF ON

ON OFF ON OFF ON OFF ON

Page 22: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

87

65

4

910

111

23 +V output (see load curve)

dc COMMON

RELAY OUTPUT 5 AMP CONTACTS

210 to 250V ac

CP12RC

SOURCING INPUT

SINKING INPUT

CR

+12V CR

SINKING INPUT

87

65

4

910

111

23

CR

+V output (see load curve)

dc COMMON

RELAY OUTPUT 5 AMP CONTACTS

105 to 130V ac

CP12RCSOURCING INPUT

+12V CR

MODEL

CP12C

CP12RC

None

MAXI-AMP CP Series power supply modules provide a convenientsource of power for 10 to 30V dc sensing devices such as Banner self-contained dc sensors and/or any of the Banner logic modules andremote amplifiers. It is an excellent way to supply power to a systemusing multiple MAXI-AMP modules and associated sensors.

These supplies are designed for either 120 or 220/240V ac inputvoltage (see hookup diagrams). They offer 400 milliamps for power-ing 10 to 30V dc devices.

Model CP12RC includes a relay which may be switched by the outputof dc sensors or modules. The relay is a single-pole double-throw(SPDT) 5 amp electromechanical type.

CP series power supplies are built into the rugged MAXI-AMPhousing. They connect via a standard 11-pole round-pin relay socket(Banner RS-11). The RS-11 socket allows DIN rail mounting of thepower supply. Operating temperature for CP series power supplymodules is 0 to 50 degrees C (32 to 122 degrees F).

400 milli-ampsmaximumfor 10-30Vdc sensingdevices

220/240V ac Hookup Diagram, CP12C

120V ac Hookup Diagram, CP12C

220/240V ac Hookup Diagram, CP12RC

120V ac Hookup Diagram, CP12RC

105 to130V ac(15 VA)

or

210 to250V ac(15 VA)50/60Hz

SPDT5-ampelectro-mechanical

INPUTVOLTAGE

OUTPUTDEVICE

OUTPUT POWER

DimensionsLoad Curve

MAXI-AMP ™ SystemCP Series Power Supply Modules

22

Page 23: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Model RS-11 Socket

Track model DIN-35-70 accomodates one RS-11 socket. Model DIN-35-105holds two sockets. Model DIN-35-140 holds up to three sockets. The RS-11socket is designed to snap (or slide) directly into the 35mm DIN track.

35mm DIN Rail Track Model BENC-4 Enclosure

The RS-11 is supplied with a coding ring and pin (see diagram at right). This allows a MAXI-AMP to bekeyed to fit only its own 11-pin socket. The pin is installed in one of the eleven slots in the RS-11, and thenotch in the ring is aligned to slip over the pin. When the MAXI-AMP is removed from the RS-11, thecoding ring stays with the MAXI-AMP base, while the coding pin remains in the socket.

Model RS-11 is an eleven-pole round-pin screwterminal relay socket which is used to make elec-trical connections to any MAXI-AMP module.The socket provides in-line wire clamp screwterminals which will accept from one #24 AWGup to two #14 wires at each pin. The RS-11 is ULrecognized (file #E92191) and CSA approved (file#LR38486). It may be mounted directly to a panelplate or via standard 35mm DIN-rail track (seebelow). A hold-down wire is supplied with eachRS-11 socket (see Dimension Diagram on page22).

Model BENC-4 is a NEMA-4 rated corrosion-resistant enclosure for a MAXI-AMP module or other control device. It is supplied with a DIN-35-70 track foreasy mounting of one RS-11 socket. For mounting two sockets, use DIN-35-105.

MAXI-AMP SystemMounting and Accessories

23

Accessories for MAXI-AMP Modules

After the panel cutout has been completed and de-burred, slide the MAXI-AMP through the cutout andplace one clip assembly into the rectangular depressionon each of the two narrow sides of the housing. Orientclips as shown, and alternately tighten the screws forequal pressure against the inside of the panel wall. Donot overtighten the screws. Attach the optional EC11-6 extension cable (described below) to the MAXI-AMPand route the opposite end of the cable to the RS-11 (orequivalent) socket.

Model EC11-6 extension cable is 6 feet (2m) long.Clips for panel wall mounting of the MAXI-AMP areincluded with the cable.

Panel Wall Mounting of MAXI-AMP Module

Page 24: Line Product Specifications MAXI-AMP Systeminfo.bannerengineering.com/cs/groups/public/documents/literature/32882.pdf · CD5, CM5, and CL5 models include a multi-function timing logic

Banner Engineering Corp. 9714 Tenth Ave. No. Minneapolis, MN 55441 Telephone: (612)544-3164 FAX (applications): (612)544-3573

WARNING MAXI-AMP sensors, amplifiers, and logic modules do NOT include the self-checking redundant circuitrynecessary to allow their use in personnel safety applications. A sensor failure or malfunction can result in either an energized or ade-energized output condition.

Never use any MAXI-AMP product as a sensing device for personnel protection. Its use as a safety device may create an unsafecondition which could lead to serious injury or death.

Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA and ANSI machine safetystandards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, and they must NOT be usedas sensing devices for personnel protection.

!

WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace,free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does notcover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.

LR400, PT400, LP400WB

This is mild-steel flexible tubing usedwith the compression fittings, at right,to achieve maximum protection tosensor cables.I.D. = 5/16"; O.D. = 7/16".

Used to Attach Tubingto these Models

Compression FittingModel

SP300EL, SP300RL,SP300D,SP300L,LR200, PT200

CF3-8

CF7-16

Used on Sensor Models# ofWires Wire Colors

Extension CableModel

EC12E-100

EC12R-100

ESC-100

RSC-100

SSC-100

EC300E-100

EC300R-100

EC320-100

PT200, PT250, PT400,SP300RL

SP12SEL, SP12PEL

SP12SRL, SP12PRL

LR200, LR250, LR400,SP300EL

SP300D, SP300L, LP400WB,SP1000V

LR300

PT300

SP320D

2

3

3

3

5

2

2

4

White, Green

Black, Blue, Brown

White, Green, Shield

Red, Black, Shield

White, Green, Red, Black,Shield

White, Shield

Red, Shield

White, Shield, Red, Shield

Extension CableModulated remote sensors require specially de-signed cable for efficient sensor performance.Extension cable is available in 100 foot (30m)lengths.

Cable ProtectionAC-6 6 feet (1,8m)AC-30 30 feet (9m)

PVC-6 6 feet (1,8m)PVC-30 30 feet (9m)

Heavy duty PVC tubing used to pro-tect sensor cable in applications in-volving moisture and/or corrosivematerials. I.D. = 1/4"; O.D. = 3/8".

Accessories for High Performance Modulated Remote Sensors

CF3-8 3/8"-32 thread CF7-16 7/16"-20 thread