liquid phase collection system odor control 101 pncwa...includes ferrous/ferric chloride and ferrous...
TRANSCRIPT
![Page 1: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/1.jpg)
Liquid Phase Collection System Odor Control 101
Presented by
Richard Finger
![Page 2: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/2.jpg)
Presentation OutlineGeneral System ConsiderationsTreatment Technologies
Air and Pure Oxygen InjectionOxidants
Chlorine and HypochloriteHydrogen PeroxideOzone
Iron Salts
![Page 3: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/3.jpg)
Presentation Outline (Cont.)
Treatment Technologies (cont.)Caustic Dosing
ContinuousShock Dosing
Nitrate SaltsAnthraquinoneEnzymes and Bacterial Augmentation
Summary
![Page 4: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/4.jpg)
General System Considerations
Think System WideThere may be people working in the collection system downstream of chemical addition
Chemical doses (and their effects) end up at the treatment plant
Evaluate cost-effectiveness based on actual performance at your site
Conduct thorough monitoring to evaluate performance of chemicals
![Page 5: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/5.jpg)
Air and Pure Oxygen Injection
Direct Injection to ForcemainsInjection into High Pressure Side Streams or Inverted Siphons for Gravity SystemsIntroduction of Oxygen can:
Inhibit the growth of sulfate reducing bacteriaChemically oxidize sulfidePromote biological oxidation of sulfide
![Page 6: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/6.jpg)
Air and Pure Oxygen Injection (Cont)
Air InjectionNeed to Consider Forcemain ProfileNeed to Consider Forcemain CompositionBest for Pressure Systems (forcemains)Need to Know Oxygen Uptake Rate (4-20 mg/l/hr)Effective Treatment Duration is a Function of Uptake Rate.Most Effective at Inhibiting Sulfide GenerationCan be Relatively Inexpensive
![Page 7: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/7.jpg)
Air and Pure Oxygen Injection (Cont)Pure Oxygen Injection
Can Dissolve 5X More Oxygen Than with AirDoes Not Introduce Nitrogen, Thus Less Potential for Gas Accumulation at High PointsCan Usually Lease Storage/Vaporization Equipment.Will Need Booster Blower at Pressures > 40 psi
![Page 8: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/8.jpg)
OxidantsChlorine and Hypochlorite
Chlorine is Being Phased Out in Favor of HypochloriteMixes Rapidly with WastewaterRapidly Reacts with Inorganics (<1 min)Dosage Rate in Range of 8 lb Chlorine per lb SulfideTreatment Effective for About 4 HoursReasonably Simple to Implement
![Page 9: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/9.jpg)
Oxidants (Cont)Hydrogen Peroxide
Oxidizes Sulfide to Sulfate and SulfurDosage in the Range of 4-8 pounds H2O2 per Pound SulfideRequires 15-30 Minutes for Complete ReactionCan Also Serve as a Source of Oxygen to Inhibit Sulfate Reduction.Requires Special Equipment, Which Can Be Leased from VendorProvides About 4 Hours Control
![Page 10: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/10.jpg)
Hydrogen Peroxide Storage
![Page 11: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/11.jpg)
Oxidants (Cont)Ozone
Most Often Used in Pump Stations to Treat AirStrong Oxidant, Which is Not Selective for SulfideNormally Too Expensive for Liquid Stream Treatment
![Page 12: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/12.jpg)
Iron SaltsIncludes Ferrous/Ferric Chloride and Ferrous Sulfate
Sulfide is Removed by Precipitation with the IronDosage is not Stoichiometric and Varies as a Function of the Level of Control RequiredDosage in the Range of 1.5 – 2 Pounds Iron per Pound Sulfide with Limit of ~0.5 mg/l SOrganic Acids Can Interfere with ReactionCan Also Help Control Sulfides in DigestersCan be Cost EffectiveAre Classified as Hazardous Chemicals
![Page 13: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/13.jpg)
Ferric Chloride
![Page 14: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/14.jpg)
Caustic Dosing
Availability of Hydrogen Sulfide for Release to the Atmosphere is a Function of pH
![Page 15: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/15.jpg)
Effect of pH on Hydrogen Sulfide -Sulfide Equilibrium
Hydrogen sulfide-sulfide Equilibrium
0102030405060708090
100
4 5 6 7 8 9 10 11 12 13 14pH
Perc
ent o
f Tot
al
H2S HS- S=
ThisStinks!
These donot.
H2S HS-
HS-2
![Page 16: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/16.jpg)
Caustic Dosing (cont)Available Chemicals include
Sodium Hydroxide (25 and 50%)LimeMagnesium Oxide/Hydroxide
Sodium Hydroxide is Most Commonly UsedClassified as a Hazardous Chemical, so Significant Storage/Handling IssuesIf Stored On-site, Need Heat Tracing
![Page 17: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/17.jpg)
Caustic Dosing (cont)Continuous Dosing
Raising pH to Between 8 and 9 Prevents Available Sulfide from Being Released to AtmosphereCan Require a Significant Quantity of Caustic Over TimeDosage Rate is Unrelated to Sulfide Concentration, but Depends on Wastewater AlkalinityNot Commonly Used Because of Cost and Potential Treatment Plant Impacts
![Page 18: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/18.jpg)
Caustic Dosing (cont)Slug Dosing
Goal is to Raise pH to 12.5 or Above for at Least 20 MinutesInhibits Sulfide Generation by Stripping Slime LayerEffect Lasts from 4 Days to Several Weeks, so Requires Periodic Dosing During the Odor SeasonWorks on Both Forcemains and Gravity Sewers
![Page 19: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/19.jpg)
Caustic Dosing (cont)Slug Dosing (cont)
Dosage is Dependent on the Wastewater AlkalinitySignificant Risk to Collection System Personnel and Downstream FacilitiesBest Used On Sub-systems with Flows Not Exceeding 10% of Total System FlowDosing Can be Done Using Tank Truck, Thus Avoiding Fixed FacilitiesCan Be Cost Effective in Some Applications
![Page 20: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/20.jpg)
Caustic Storage Tank
![Page 21: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/21.jpg)
Nitrate SaltsMost Common Sources are Calcium and Sodium Nitrate.May be Considered Proprietary ProductsServe as an Oxygen Source, so Can Both Inhibit Sulfide Generation and Oxidize Existing SulfideGenerally Require a Period of Dosing to Achieve Full EffectDosage Varies Based on Several Factor, so Needs to be Adjusted Based on System Monitoring
![Page 22: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/22.jpg)
Nitrate Salts (cont)
Dosages in the Range of 1-3 Pounds Nitrate Oxygen per Pound of Sulfide are CommonProprietary Combinations are Available That Combine Nitrate Salts with Caustic or Other Chemicals That Inhibit Sulfate Reduction or Sulfide ReleaseProducts are Not Classified as HazardousCan Often Be a Cost Effective SolutionAvoid Calcium Nitrate When Waste Stream Contains High FOG Concentrations
![Page 23: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/23.jpg)
Nitrate Feed System
![Page 24: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/24.jpg)
Nitrate Feed System
![Page 25: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/25.jpg)
AnthriquinoneInhibits the Ability of Organisms to Reduce SulfateRequires Periodic Dosing as Effect Wears OffHas Not Worked in Some ApplicationsAvailable in Combination with Nitrate Products (Proprietary Product)Cost Effectiveness Needs to be Evaluated On-site
![Page 26: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/26.jpg)
Enzymes and Bacterial Augmentation
Focus is on Changing the System EcologyLimited Data on Effectiveness
![Page 27: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/27.jpg)
Discussion
Many Technologies/Approaches AvailableApplications are Often Site Specific Due to Both System Characteristics and Local Chemical Price VariabilitySystems Should Be Tested Prior To ImplementationSystems Should Be Re-evaluated PeriodicallySpend 1% to 10% of Annual Chemical Cost Tracking Performance
![Page 28: Liquid Phase Collection System Odor Control 101 PNCWA...Includes Ferrous/Ferric Chloride and Ferrous Sulfate Sulfide is Removed by Precipitation with the Iron Dosage is not Stoichiometric](https://reader030.vdocuments.net/reader030/viewer/2022040806/5e46d57641697c05e9344bd5/html5/thumbnails/28.jpg)
Evaluation Criteria For Choosing an Odor Control Method
Characteristics of the wastewaterType of odor being controlledCost EffectivenessSafetyRegulatory compliance
OperabilityMaintainabilityEnvironmental issuesSite space availableAesthetics
Discussion