liquid target system for new tpc experiment
DESCRIPTION
Liquid target system for New TPC experiment. System Target cell Performance in test experiment Plan for next experiment Perspective. CFRP (1mm). L.T. System. g. 40 mm. ~500 mm. 145 mm. Target. Kapton Cell. Temperature sensor (Cernox). Target stage. 25mm. 33 mm. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/1.jpg)
Liquid target system for New TPC experiment
•System•Target cell•Performance in test experiment•Plan for next experiment•Perspective
![Page 2: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/2.jpg)
L.T. System
CFRP (1mm)
![Page 3: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/3.jpg)
Target
~500 mm145 mm
40 mm
33 m
m
25mm
Kapton Cell
Target stage
Temperature sensor (Cernox)
![Page 4: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/4.jpg)
Target Cell (Kapton 125 um)Nagai manufacturing Co.,Ltd.( www.nagai-mfg.co.jp )Plastic molding, etc.
Leak test (2 atm) using N2 gas.
![Page 5: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/5.jpg)
Shielding
![Page 6: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/6.jpg)
Operation
• 145 mm long target cell
Filled gas with 1.35 atm using default preserver tank (120x6 litter)
• Temperature controll (Lake Shore)
set requested temperature
The heat voltage is controlled automatically.
![Page 7: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/7.jpg)
17K15.8K
Test (Hydrogen)
![Page 8: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/8.jpg)
For next experiment
100 mm longer
![Page 9: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/9.jpg)
TargetCollimatorHole 31.7x24 mm
2 T
T=3 GeV, N=105, (x,y)=(8mm,4mm)
(In&Out&Upbar)No LH2 3 No buffer 11LH2 12
33x25 mm
Setup
(100)3 mm
![Page 10: Liquid target system for New TPC experiment](https://reader036.vdocuments.net/reader036/viewer/2022062314/56813354550346895d9a6364/html5/thumbnails/10.jpg)
Further
• Helium 4
The liquidized was achieved using copper cell at Suzuki co.
R&D for the target cell
Kapton Aramid, etc.