list of prerequisites anlist of prerequisites and creditsd credits

1
NC Ver. 2.2 NC 2009 Notes for NC Ver. 2.2 Notes for NC 2009 WEp1 Water Use Reduction N/A Use 20% less water than baseline. WEc2 WEc2 Innovative Wastewater Technologies Use water-conserving fixtures to reduce sewage by 50% Use water-conserving fixtures to reduce sewage by 50% WEc3 WEc3 Water Use Reduction Use 20% (1 Point)/30% (2 Points) less water than baseline. Use 30% (2 Point)/35% (3 Points)/40% (4 points)/45% (innovation credit) less water than baseline. Baseline requires lower water usage for lavatories and kitchen faucets. EAp1 EAp1 Fundamental Commissioning of the Building Energy Systems EAp2 EAp2 Minimum Energy Performance Use 10% less energy than baseline (ASHRAE 90.1- 2007 Appendix G) EAp3 EAp3 Fundamental Refrigerant Management EAc1 EAc1 Optimize Energy Performance Required minimum, use 14% less energy than baseline (ASHRAE 90.1-2004 Appendix G) Points start at 12% energy savings compared to baseline (ASHRAE 90.1-2007 Appendix G) EAc3 EAc3 Enhanced Commissioning EAc4 EAc4 Enhanced Refrigerant Management EAc5 EAc5 Measurement and Verification Requirement has been added to provide a process for corrective action if the results of the M&V plan indicate that energy savings are not being achieved. EQp1 IEQp1 Minimum IAQ Performance Based on ASHRAE 62.1-2004 Based on ASHRAE 62.1-2007 EQc1 IEQc1 Outdoor Air Delivery Monitoring EQc2 IEQc2 Increased Ventilation Based on ASHRAE 62.1-2004 Based on ASHRAE 62.1-2007 EQc5 IEQc5 Indoor Chemical & Pollutant Source Control EQc6 IEQc6 Controllability of Systems: Thermal Comfort Based on ASHRAE 62.1-2004 and ASHRAE 55- 2004. Based on ASHRAE 62.1-2007 and ASHRAE 55-2004. EQc7 IEQc7 Thermal Comfort: Design

Upload: anon350

Post on 17-Dec-2015

215 views

Category:

Documents


1 download

DESCRIPTION

List of Prerequisites and Credits

TRANSCRIPT

  • NC Ver. 2.2

    NC 2009 Notes for NC Ver. 2.2 Notes for NC 2009

    WEp1 Water Use Reduction N/A Use 20% less water than baseline.

    WEc2 WEc2 Innovative Wastewater TechnologiesUse water-conserving fixtures to reduce sewage by 50%

    Use water-conserving fixtures to reduce sewage by 50%

    WEc3 WEc3 Water Use ReductionUse 20% (1 Point)/30% (2 Points) less water than baseline.

    Use 30% (2 Point)/35% (3 Points)/40% (4 points)/45% (innovation credit) less water than baseline. Baseline requires lower water usage for lavatories and kitchen faucets.

    EAp1 EAp1Fundamental Commissioning of the Building Energy Systems

    EAp2 EAp2 Minimum Energy PerformanceUse 10% less energy than baseline (ASHRAE 90.1-2007 Appendix G)

    EAp3 EAp3 Fundamental Refrigerant Management

    EAc1 EAc1 Optimize Energy PerformanceRequired minimum, use 14% less energy than baseline (ASHRAE 90.1-2004 Appendix G)

    Points start at 12% energy savings compared to baseline (ASHRAE 90.1-2007 Appendix G)

    EAc3 EAc3 Enhanced CommissioningEAc4 EAc4 Enhanced Refrigerant Management

    EAc5 EAc5 Measurement and Verification

    Requirement has been added to provide a process for corrective action if the results of the M&V plan indicate that energy savings are not being achieved.

    EQp1 IEQp1 Minimum IAQ Performance Based on ASHRAE 62.1-2004 Based on ASHRAE 62.1-2007EQc1 IEQc1 Outdoor Air Delivery MonitoringEQc2 IEQc2 Increased Ventilation Based on ASHRAE 62.1-2004 Based on ASHRAE 62.1-2007

    EQc5 IEQc5Indoor Chemical & Pollutant Source Control

    EQc6 IEQc6Controllability of Systems: Thermal Comfort

    Based on ASHRAE 62.1-2004 and ASHRAE 55-2004. Based on ASHRAE 62.1-2007 and ASHRAE 55-2004.

    EQc7 IEQc7 Thermal Comfort: Design

    Sheet1