literature result - parker - retemretem.com/pictures/parker hydraulic filters[1].pdf · high...

19
Spin-on Filters Maxiflow Series MAX 360 I/min - 10 bar Low pressure filters 61

Upload: buitu

Post on 26-Jul-2018

241 views

Category:

Documents


0 download

TRANSCRIPT

Spin-on Filters

Maxiflow SeriesMAX 360 I/min - 10 bar

Low pressure filters61

Spin-on Filters

Maxiflow Series

Typical Applications

Telescopic handlersRefuse vehiclesRoad sweepersCompactorsIndustrial power unitsGrass cuttersPress brakes

The Parker Filtration Maxiflow Full FlowFilters for Suction or Return.Maxiflow type MXA8 and MXA9 feature twointegral red/green indicators incorporated into thehead. Fitted as standard, they ensure maximumindicator visibility and early warning of filtercondition.

Maxiflow type MXA7 features one integral indicator.

Features & Benefits

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 7

62

Features

Integrated indicator

High quality paint for canisters

Spin-on filters available for suctionand return line filtration

High quality filter medium

Advantages

Compact and robust durable construction

Long term protection against corrosion

Flexible product offering

Filter medium suitable for fatigue load due tohigh frequent flow fluctuation

Benefits

Easy identification of element status

Improved protection of filter medium

Standardisation of components

Extended element life time

Circuit symbol

Low pressure filters

Installation Details

Specification

Preferred Series MXA PS SeriesMaximum working pressure: 10 bar 10 barFilter head material: Aluminium LM24 Aluminium alloyFilter bowl material: Steel SteelSeal material: Nitrile Buna (nitrile)Operating temperature range: -30°C to +90°C -30°C to +110°CBypass: Return line 1.05 bar Return line 1.5 bar

Suction line 0.17 bar Suction line 0.10 barNo bypass option No bypass option

Fluids: Mineral oils Mineral oilsElement media: Microglass III media Microglass III media

Cellulose media Cellulose media

63

F

C

DB

20

Minimum for elementremoval

G

H

M

2 mounting holes‘L’

K

ØJ

Filter selectionTo select the correct filter use the appropriatepressure drop graphs. For details and an exampleof how to select the correct filter, see next page.

A

Element removalclearance

D12

PS-1

522

PS-2

0

C

B

A

F

Inlet

KH

L

MXA.8/MXA.9*** 12PS/22PS MXA.7***

Type

G3/4

G11/4

G11/2

19(0.75)

22(0.86)

30(1.18)

28(1.10)430

(16.93)

147(5.79)165

(6.49)179

(7.04)208

(8.19)179

(7.05)

173(6.81)187

(7.36)213

(8.38)236

(9.29)214

(8.42)

95(3.74)

95(3.74)133

(5.24)133

(5.23)140

(5.51)

97(3.82)

N/A

129(5.08)

N/A

N/A

38(1.49)

38(1.49)

50(1.97)

50(1.97)

65(2.56)

94(3.7)93

(3.66)127(5.0)130

(5.12)127(5.0)

88(3.46)107

(4.21)130

(5.12)

N/A

M8 x1.25 x 16full depth

M10 x 1.5

72(2.83)

N/A

72(2.83)

N/A

MXA.8

12PS

MXA.9

22PS

MXA.7

A B C D F G H J K L M

J

Minimum forelement removal

102 (4.01)70

(2.75)Minimum forelement removal

20(0

.79)

DC123 (4.84)

20(0

.79)

2 mounting holes‘L’

70

F

HØ129

A

2 ports 1/8” BSPT foroptional indicators

Ø54

(2.1

2)B

Spin-on Filters

Maxiflow SeriesPressure Drop Curves

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 7

64

Filter Housing

Maxiflow (MXA.8*** Series) and 12PS Series

0

0.2

0.4

0.6

0.8

1.0

0 10 20 30 12011010040 50 60 70 80 90

Flow (l/min)

Δp

(ba

r)

Flow (US GPM)

0 3 8 11 165 13 18 21 24 26 29Δ

p(P

SID

)

0

2.9

14.5

11.6

8.7

5.8

31

0

0.1

0.2

0.3

0.4

0.5

0 10 20 30 12011010040 50 60 70 80 90

Flow (l/min)

Δp

(ba

r)

Flow (US GPM)

10µ Abs

10µ Nom

0 3 8 11 16 315 13 18 21 24 26 29

Δp

(PS

ID)

0

1.5

7.3

5.8

4.4

2.9

Filter Element

Filter Housing

Maxiflow (MXA.9*** Series) and 22PS Series

0

0.1

0.2

0.4

0.3

Δp

(ba

r)

0 80 200 220 24018016014012010020 40 60

Flow (l/min)

Flow (US GPM)

0 5 16 21 3111 26 37 42 47 53 58

Δp

(PS

ID)

0

1.5

5.8

4.4

2.9

61

0 10020 40 60 80 200120 140 160 180 220 240

Flow (l/min)

0

0.2

0.4

0.6

0.8

1.0

Δp

(ba

r)

10µ Abs

Flow (US GPM)

0 5 16 21 3111 26 37 42 47 53 58

Δp

(PS

ID)

0

2.9

14.5

11.6

8.7

5.8

64

10µ Nom

Filter Element

Filter Housing

Maxiflow (MXA.7*** Series)

0

0.1

0.3

0.4

0.6

Δp

(ba

r)

0.7

0.5

0.2

0 100 200 300 40050 150 250 350

Flow (l/min)

Flow (US GPM)

0 26 5313 39 66 79 92

Δp

(PS

ID)

0

2.9

10.2

8.7

7.3

4.4

106

5.8

1.5

1000 40050 150 300 3502502000

0.1

0.8

0.7

0.6

0.5

0.4

0.3

0.2

Flow (l/min)

Δp

(ba

r) 10µ Abs

Flow (US GPM)

0 13 26 39 53 66 79 92

Δp

(PS

ID)

0

1.5

11.6

8.7

7.3

4.4

106

10.2

5.8

2.9

10µ Nom

Filter Element

The recommended level of the initial pressure drop for low pressure filters is max 0.5 bar.If the medium used has a viscosity different from 30cSt, pressure drop over the filter can be estimated as follows:!p = (!p30 x viscosity of medium used) / 30cSt.

Note: All above data is calculated at 30cSt Rel density 0.856.

Low pressure filters

Ordering Information

65

MXAPS

MXA855142412PS10BTV1R2B

Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicators MXR8550G3/4

10 micronabs.7010

MXA.8*** & 12PS Return Line Filters

Type Part number DescriptionMAOP Flow Media

PortsReplacement

(bar) (l/min) rating element

MXA MXA9561424 Assembly with bypass & dual visual indicators MXR9560G11/43 micron

abs.3010

MXA.9*** & 22PS Return Line Filters

MXA.7*** Suction Line Filters

MXA MXA7551424 Assembly with bypass & dual visual indicators MXR9550G11/210 micron

abs.30010

MXA.7*** Return Line Filters

MXA MXA7511424 Assembly with bypass & dual visual indicatorsMX1591410

(x4*)G11/210 micron

nom.35010

MXAPS

MXAPS

MXA851122312PS10CTV1S4BMXA851022312PS10CTV1SX4B

Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorAssembly without bypass, with dual visual indicatorsAssembly without bypass, with gauge type visual indicator

MX1518410(x4*)

G3/410 micron

nom.2010

MXA.8*** & 12PS Suction Line Filters

MXAPS

MXAPS

MXA951122322PS10CTV2S4DMXA951102322PS10CTPSX4D

Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorAssembly without bypass, with visual indicatorsAssembly without bypass, no indicator

MX1591410(x4*)

G11/4

10micronnom.

4810

MXA.9*** & 22PS Suction Line Filters

MXAPSPSPS

MXA951142422PS10CTV1R2D22PS10CTE2R2D22PS10CTPR2D

Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorAssembly with bypass & electrical pressure indicatorAssembly with bypass & no indicator

MX1591410(x4*)

G11/4

10micronnom.

18010

MXA

PS

MXA851142412PS10CTV1R2B12PS10CTE2R2B12PS10CTPR2B

Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorsAssembly with bypass & electrical pressure indicatorAssembly with bypass & no indicator

MX1518410(x4*)

G3/410 micron

nom.7010

3 Micron abs. filtration for Off-Line and Bypass System Clean UpMaxiflow 3 micron elements are ideal for off-line or bypass clean up applications. These can be specified for the 9*** and 7*** series return line filters

The Maxiflow Series 7*** can be specified with additional visual or electrical indicators. Please consult Parker Filtration for details

Note: Elements marked with (x4*) are only available in packs of 4

MXAPSPSPS

MXA955142422PS10BTV1R2D22PS10BTE2R2D22PS10BTPR2D

Assembly with bypass & dual visual indicatorsAssembly with bypass & gauge type visual indicatorsAssembly with bypass & electrical pressure indicatorAssembly with bypass & no indicator

MXR9550G11/4

10micronabs.

18010

MXAMXA7551223MXA7551023

Assembly with bypass & visual indicatorsAssembly without bypass with visual indicators

MXR9550G11/210 micron

abs.8010

MXAMXA7511223MXA7511023

Assembly with bypass & visual indicatorsAssembly without bypass with visual indicators

MX1591410(x4*)G11/2

10 micronnom.8010

High Pressure Filters

15P/30P SeriesMAX 200 I/min - 207 bar

High pressure filters95

High Pressure Filters

15P/30P SeriesFeatures & Benefits

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 12

96

The Parker Filtration 15P/30P SeriesHigh Pressure Filters.These application examples have one thing incommon...the need for clean hydraulic fluid.

Modern high pressure hydraulic systems aredemanding. Better controls and long componentlife are expected. To deliver the high standards ofperformance, hydraulic components are built withtighter tolerances which increases their sensitivityto contamination.

That’s where Parker pressure filters come intoplay. They filter out ingressed contamination beforeit jams a valve or scores a cylinder. They blockpump generated debris before it gets to servoor proportional valves. Parker pressure filtersare a key ingredient in meeting today’s systemdemands.

Put your hydraulic systems in the care of ParkerFiltration. We are committed to designing andbuilding the best filters available to industry.

Features

Compact aluminium housing

Two head sizes and two bowllengths

Large ports and wide flow paths

Microglass III replacement elements

Visual, electrical and electronicindicators available

Advantages

Light weight but still robust design

Optimised sizing

Low differential pressure across housingand element

Multi-layered design produced high capacityand efficiency

Wire support reduces pleat bunching, keepsperformance consistent

Check element condition at a glance

Right style for the application

Benefits

Reliable and continuous operation bothin mobile and industrial applications

Efficient filtration

Right filter for each application

Higher flow rates possible

Less lost energy

Great performance value

Reliable performance throughoutelement life

Reduces downtime, maximiseselement life

Optimise element life, prevent bypassing

Matches your system electricalconnections

Typical Applications

Saw millsAircraft ground support equipmentAsphalt paversHydraulic fan drivesPower steering circuitsDomestic refuse vehiclesCement trucksServo control protectionLogging equipment

High pressure filters

Installation Details

Specification

Pressure ratings:Maximum allowable operating pressure 207 bar.Filter housing pressure pulse fatigue tested: 138 bar.Connections:Inlet and outlet connections are threaded.Connection style Model

15P 30PBSPF(G) 3/4” 1”ISO 6149 M27 M33

Filter housing:Head material extruded aluminium (anodised 6061-T6).Bowl material impacted aluminium (anodised 6061-T6).Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve:Opening pressure 3.5 bar.Filter element:Degree of filtration:Determined by multipass-test according to ISO 16889.

Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved(ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap materialreinforced composite and metal inner core. Collapse rating 24 bar(ISO 2941).High collapse elements:High collapse elements available. For details please contactParker Filtration.Indicator options:Indicating differential pressure: 2.5 ± 0.3 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 215P 1.6 2.130P 2.9 3.9Fluid compatibility:Suitable for use with mineral and vegetable oils, and somesynthetic oils. For other fluids, please consult Parker Filtration.

97

Bottom View

64.32.53

23.9.94

49.01.93

155.36.11

15P-1

15P-1

173.5-2.36.83-0.9

50.82.00

Minimumcartridge removal

clearance

Optional 5/16 SAE-5drain porttorque 20-27 Nm(15-20 ft lbs)

Torque 40-48 Nm

Torque 74-95 Nm(55-70 Ft lbs)

101.64.0023.0

.91

50.51.99

46.01.81

79.431.3

Dia.

21.8.86

25.41.000

62.52.46

6.22.25

250.49.86

15P-2268.7–.2.310.58–.09

15P-2

6.8–.13.266–.005

79.4–.133.125–.005

15P Series

High Pressure Filters

15P/30P SeriesInstallation Details (cont.)

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 12

98

1 Head2 Bypass assembly3 Element See chart in product configurator4 Bowl O-ring – buna N92138 N92151

Bowl O-ring – fluoroelastomer V92138 V921515 Bowl6 Drain plug – c/w buna seal

Drain plug – c/wFluoroelastomer seal

7 Nameplate10 Blank indicator kit11 Indicators

M3 – Visual auto reset indicator FMUM3KVAU14MT1 – Electrical indicator FMUT1KVAU14MF1 – Electronic indicatorPNP with 4 LED FMUF1KVAU14MF2 – Electronic indicatorNPN with 4 LED FMUF2KVAU14M

Index Description 15P 30P

66.72.63

90.13.55

Torque 74-95 Nm (55-70 Ft lbs)

3.0.12

51.42.02

210.08.27

30P-1 30P-1

229.69.04

Torque 88-95 Nm(65-70 Ft lbs)

Optional str thd drain port5/16 SAE-5 (11/2-20 UNF-2B)Torque 20-27 Nm (15-20 Ft lbs)

101.64.00

Minimumcartridgeremoval

clearance

Side view

69.92.750

34.91.375 10.3

.406dia thru 2 total

19.1.75

31.81.25

Optional mounting bracket (925563)

101.64.000

Port to port

52.32.06

92.13.63

dia

28.81.12

Hex

Bottom view104.84.13

dia

24.4.96

338.813.34

30P-2

75.22.96

319.312.5730P-2

mm(inches)

30P Series

1

2

3

4

5

6

6

5

4

3

1

7

10

11

High pressure filters

Pressure Drop Curves

99

The recommended level of the initial pressure drop is max. 1.2 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:!p = (!p30 x viscosity of medium used) / 30 cSt.

15P-1 Elements

15P-2 Elements

15P Empty Housing

25

20

15

5

0

10

Flow (US GPM)

Flow (l/min)

20 40 600.0

Δp

(ba

r)

0.5

1.0

1.5

0

10 15 20 2550

80 100

02Q

05Q

20Q

10Q

Δp

(PS

ID)

Δp

(ba

r)

0 20 40 60 80

Flow (l/min)

Flow (US GPM)

Δp

(PS

ID)

0 5 10 15 20 2525

20

15

10

5

0

1.5

1.0

0.5

0.0

15P-115P-2

25

20

15

5

0

10

Flow (US GPM)

Flow (l/min)

20 40 600.0

Δp

(ba

r)

0.5

1.0

1.5

0

10 15 20 2550

80 100

02Q

05Q

20Q10Q

Δp

(PS

ID)

30P-1 Elements

30P Empty Housing

25

20

15

5

0

10

Flow (US GPM)

Δp

(PS

ID)

Flow (l/min)

0.0

Δp

(ba

r)

0.5

1.0

1.5

02Q05Q

20Q

10Q

0 13 26 66

50 100 2502000

53

150 300

39 79

Δp

(ba

r)

0 50 100 150 200

Flow (l/min)

Flow (US GPM)

Δp

(PS

ID)

0 10 20 40 50 6025

20

15

10

5

0

1.5

1.0

0.5

0.0

30P-130P-2

30

30P-2 Elements

25

20

15

5

0

10

Flow (US GPM)

Δp

(PS

ID)

Flow (l/min)

0.0

Δp

(ba

r)

0.5

1.0

1.5

02Q

05Q

20Q

10Q

0 13 26 66

50 100 2502000

53

150 300

39 79

High Pressure Filters

15P/30P SeriesOrdering Information

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 12

100

Note: Filter assemblies ordered from the product configurator below are on extended lead times. Where possible, please make your selection from the table above.

Part number

15P110QBM3KG12115P110QBT1KG12115P210QBM3KG12115P210QBT1KG12130P110QBM3KG16130P110QBT1KG16130P210QBM3KG16130P210QBT1KG161

Supersedes

15P-1-10Q-M2-50-B2B2-115P-1-10Q-TW3-50-B2B2-115P-2-10Q-M2-50-B2B2-115P-2-10Q-TW3-50-B2B2-130P-1-10Q-M2-50-C2C2-130P-1-10Q-TW3-50-C2C2-130P-2-10Q-M2-50-C2C2-130P-2-10Q-TW3-50-C2C2-1

Flow(l/min)

45457070120120170170

Modelnumber

15P15P15P15P30P30P30P30P

Elementlength

Length 1Length 1Length 2Length 2Length 1Length 1Length 2Length 2

Mediarating (µ)

1010101010101010

Seals

NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile

Indicator

VisualElectrical

VisualElectrical

VisualElectrical

VisualElectrical

Bypasssettings

3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar3.5 bar

Replacementelements

939102Q939102Q939106Q939106Q939110Q939110Q939114Q939114Q

Ports

G3/4"G3/4"G3/4"G3/4"G1"G1"G1"G1"

Product configuratorBox 1

Code12

LengthLength 1Length 2

Filter typeBox 2

15PBox 2

1Box 3

10QBox 4

BBox 5

M3Box 6

KBox 7

G12Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve3.5 bar

Bypass and indicator settingsIndicator

2.5 barCode

K

Box 6

CodeP

M3T1NF1F2F3F4

Plugged with steel plugVisual indicatorElectrical indicatorNo indicator portElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.

IndicatorBox 5

CodeG12M27G16M33

Connections15P: Thread G3/4

Thread M27, ISO 614930P: Thread G 1

Thread M33, ISO 6149

Filter connectionBox 7

Code14

OptionsStandardDrain port on bowl

OptionsBox 8

Code15P30P

ModelHigh pressure filter, T-portHigh pressure filter, T-port

CodeBox 1

Standard products table

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

Media02Q05Q10Q20Q

Replacement elements with nitrile seals15P-1

939100Q939101Q939102Q939103Q

15P-2939104Q939105Q939106Q939107Q

30P-1939108Q939109Q939110Q939111Q

30P-2939112Q939113Q939114Q939115Q

Filter model15P-115P-230P-130P-2

Nominal flow (I/min) at viscosity 30 cSt02Q254070

120

05Q306090

150

10Q4570

120170

20Q7090

170200

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Item is standardItem is standard green optionItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available within four weeks

Box 3

Element media

Microglass III element 20Q10Q05Q02Q

Glass fibreMedia code

Degree of filtration

Average filtration beta ratio ß (ISO 16889) / particle size µm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

High Pressure Filters

18/28/38P SeriesMAX 700 I/min - 414 bar

High pressure filters107

High Pressure Filters

18/28/38P Series

Typical Applications

Injection mouldingDie castingServo controlsMachine toolsMobile equipment

The Parker Filtration 18/28/38P SeriesHigh Pressure FiltersParker Filtration engineered the 18/28/38P series of high pressure filtersto satisfy demanding applications in the mobile and industrial marketsthroughout the world. With metric mounting and optional ISO 6149ports, this new series is truly a global design.

Installed downstream of the pump, this new series with their wide rangeof high capacity Microglass III elements, offer excellent protection tosystem components.

Standard filters come complete with industry proven spool type bypassvalve. For more critical applications such as servo or proportionalcontrols, a no bypass high strength element combination ensuresmaximum protection.

The modular low hysteresis differential pressure indicator fitted to thisseries is unrivaled in its performance. Tests prove its accuracy andfoolproof design to be a major advance in indicator technology.

Features & Benefits

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14

108

Features

Fatigue tested to full pressure rating

Several head sizes

Several connection options

Microglass III replacement elements

Visual, electrical and electronicindicators available

Advantages

Strong and robust housing for heavy dutyapplications

Optimised sizing

Easy mounting

Multi-layered design produced high capacity andefficiency

Wire support reduces pleat bunching, keepsperformance consistent

Check element condition at a glance

Right style for the application

Benefits

Reliable and continuous operation bothin mobile and industrial applications

Efficient filtrationCovers wide flow range

Global design, global acceptanceRight filter for each application

Great performance valueReliable performance throughoutelement lifeReduces downtime, maximiseselement lifeOptimises element life, preventsbypassingMatches your system electricalconnections

18P 28P 38P

B C

Torque22-27Nm

(15-20 ft/lbs)

A Length 1

A Length 2

Hex. E

Bowl removalF

CB

A Length 1

A Length 2

Bowl removalF

Hex.

Torque35-40 Nm

(25-30 ft/lbs)

B C

A Length 1

A Length 2

Bowl removalF

Torque80-95 Nm

(60-70 ft/lbs)

Hex.

K

H

J

LN

M

15°

4 mounting holes (P)

G

H

J

K

LM

N

4 mounting holes (P)

15°R30

R35

G

JH

NM

15°

LK

4 mounting holes (P)

mm(inches)

D DD

G

R38

EE

High pressure filters

Specification

Pressure ratings:Maximum allowable operating pressure 414 bar.Filter housing pressure pulse fatigue tested: 106 pulses 0 - 414 bar.Connections:Inlet and outlet connections are threaded internally or flange faced.Connection style Model

18P 28P 38PBSPF(G) 3/4” 1” 11/4”, 11/2”SAE 12 16 20, 24ISO 6149 M27 M33 M42, M48Flange SAE 6000 3/4” 1” 11/4”Flange SAE 6000-M* 3/4” 1” 11/4”*6000-M is a SAE style with appropriate metric fixing threads.Filter housing:Head material cast iron (GSI).Bowl material steel.Seal material:Nitrile or Fluoroelastomer.Operating temperature range:-20°C to +100°C.Bypass valve & indicator settings:Table below gives bypass valve and corresponding indicator setting.Bypass Indicator3.5 bar 2.5 bar7.0 bar 5.0 bar

109

Filter element:Degree of filtration:Determined by multipass-test according to ISO 16889.Flow fatigue characteristics:Filter media is supported so that the optimal fatigue life is achieved (ISO 3724).Microglass III:Supported with epoxy coated metal wire mesh, end cap material reinforcedcomposite and metal inner core. Collapse rating 20 bar (ISO 2941).High collapse elements:(To be used when no bypass function in filter housing).Microglass III media supported with epoxy coated metal wire mesh onupstream and stainless steel on downstream, end cap material steel.Strong metal inner core. Collapse rating 210 bar (ISO 2941).Indicator options:Indicating differential pressure: 2.5 ± 0.3 bar or 5.0 ± 0.5 bar.- visual M3.- electrical T1.- electronic F1(PNP).- electronic F2(NPN).For indicator details see catalogue section 6.Weights (kg):Model Length 1 Length 218P 4.2 5.728P 6.7 9.238P 15.8 20.3Fluid compatibility:Suitable for use with mineral and vegetable oils, and some synthetic oils.For other fluids, please consult Parker Filtration.

Model

198(7.79)293

(11.53)228

(8.97)337

(13.26)329

(12.95)448

(17.64)

32(1.26)

40(1.57)

44(1.73)

26(1.02)

29(1.14)

35(1.38)

75(2.95)

93(3.66)

128(5.04)

24(0.94)

24(0.94)

36(1.42)

100(3.94)

98(3.86)

120(4.72)

160(6.30)

40(1.57)

55(2.16)

50(1.97)

20(0.79)

27.5(1.07)

25(0.98)

80(3.15)

90(3.54)

120(4.72)

40(1.57)

45(1.77)

60(2.36)

55(2.16)

62(2.44)

81(3.19)

110(4.33)

124(4.88)

162(6.38)

M8 x 1.25x12

deep

M10 x 1.5x11

deep

M10 x 1.5x12

deep

18P-1

18P-2

28P-1

28P-2

38P-1

38P-2

A B C D E F G H J K L M N P(A/F)

High Pressure Filters

18/28/38P SeriesFlange Face Details

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14

110

Modelmm (inches)

11.9

(0.47)

14

(0.55)

15.7

(0.62)

23.8

(0.94)

27.8

(1.09)

31.7

(1.25)

25.4

(1.00)

28.0

(1.10)

33.0

(1.30)

50.8

(2.0)

57.1

(2.25)

66.7

(2.62)

M10 x 1.5-6H x 18 Deep

M12 x 1.75-6H x 20 Deep

M14 x 2-6H x 20 Deep

3/8-16 UNC-2B x 18 deep

7/16-14 UNC-2B x 20 deep

1/2-13 UNC-2B x 20 deep

19.0

(0.75)

25.4

(1.0)

31.8

(1.25)

18P (3/4”)

28P (1”)

38P (11/4”)

A B C D E F G

C

D

AB

ØG

Thread E metricF SAE

High pressure filters

Pressure Drop Curves

111

18P-1 Empty Housing and High Collapse

28P-1 Elements

18P-1 Elements

18P-2 High Collapse Elements

28P-2 Elements

43.5

29.0

0

1150 21

Flow (US GPM)

Flow (l/min)20 6040 120 14010080

0.0

Δp(b

ar)

20Q1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

16

14.5

Δp(P

SID

)

10Q

05Q02Q

160

26 32 37 42

Empty Housing

43.5

29.0

0

1150 21

Flow (US GPM)

Flow (l/min)20 6040 120 14010080

0.0

Δp(b

ar)

20Q1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

16

14.5

Δp(P

SID

)

10Q

05Q

02Q

160

26 32 37 42

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp(b

ar)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp(P

SID

)

10Q

05Q

02Q

150 300

39 79

43.5

29.0

0

1150 21

Flow (US GPM)

Flow (l/min)20 6040 120 14010080

0.0

Δp(b

ar)

20Q1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

16

14.5

Δp(P

SID

)

10Q05Q

02Q

160

26 32 37 42

18P-2 Elements

43.5

29.0

0

1150 21

Flow (US GPM)

Flow (l/min)20 6040 120 14010080

0.0Δp

(bar

)20Q

1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

16

14.5

Δp(P

SID

)

10Q

05Q

02Q

160

26 32 37 42

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp(b

ar)

20Q1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp(P

SID

)

10Q05Q

02Q

150 300

39 79

28P-1 Empty Housing and High Collapse 28P-2 High Collapse Elements

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp(b

ar)

20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp(P

SID

)

10QH05QH02QH

150 300

39 79

Empty Housing

43.5

29.0

0

0 13 26 66

Flow (US GPM)

Flow (l/min)50 100 250200

0.0

Δp(b

ar) 20QH

1.0

2.0

3.0

0

0.5

1.5

2.5

53

14.5

Δp(P

SID

)

10QH05QH02QH

150 300

39 79

With 3.5 bar bypass the recommended initial pressure drop is max 1.2 bar.With 7.0 bar bypass the recommended initial pressure drop is max 2.3 bar.If the medium used has a viscosity different from 30 cSt, pressure drop over the filter can be estimated as follows:The total !p = housing !ph + (element !pe x working viscosity/30).

High Pressure Filters

18/28/38P Series

Element Service

Pressure Drop Curves (cont.)

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14

112

38P-1 Empty Housing and High Collapse

38P-1 Elements

38P-2 High Collapse Elements

43.5

29.0

0

132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp(b

ar) 20Q

1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

106

14.5

Δp(P

SID

)

10Q05Q

02Q

300

7953260 185159

700600

Empty Housing

43.5

29.0

0

132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp(b

ar) 20Q

1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

106

14.5

Δp(P

SID

)

10Q05Q

02Q

300

7953260 185159

700600

43.5

29.0

0

132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp(b

ar)

20Q1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

106

14.5

Δp(P

SID

)

10Q

05Q02Q

300

7953260 185159

700600

38P-2 Elements

43.5

29.0

0

132

Flow (US GPM)

Flow (l/min)100 200 500400

0.0

Δp(b

ar)

20Q

1.0

2.0

3.0

3.5

0

0.5

1.5

2.5

106

14.5

Δp(P

SID

)

10Q

05Q

02Q

300

7953260 185159

700600

A. Stop the system’s power unit.B. Relieve any system pressure in the filter line.C. Drain the filter bowl if drain port option is provided.D. Rotate the bowl clockwise (left) and remove.E. Remove element by pulling downward with a

slight twisting motion and discard.F. Check bowl o-ring and anti-extrusion ring for

damage and replace if necessary.G. Lubricate element o-ring with system fluid and

locate element in filter head.H. Install bowl by rotating counter-clockwise (right)

and tighten to specified torque.18P - 22-27 Nm (16-20 ft. lbs.)28P - 35-40 Nm (25-30 ft. lbs.)38P - 80-95 Nm (60-70 ft. lbs.)

I. Confirm there are no leaks after poweringthe system.

Head AssemblyElementBowlIndicatorsM3 – Visual auto reset; 2.5 barM3 – Visual auto reset; 5.0 barT1 – Electrical; 2.5 bar with

DIN 43650 ConnectorT1 – Electrical; 5.0 bar with

DIN 43650 ConnectorF1 – Electronic PNP; 2.5 bar with 4 LEDF2 – Electronic NPN; 2.5 bar with 4 LEDF1 – Electronic PNP; 5.0 bar with 4 LEDF2 – Electronic NPN; 5.0 bar with 4 LEDBowl SealBowl Anti-extrusion RingSeal KitsSeal kit 18P (std) – NitrileSeal kit 18P (F3) – FluoroelastomerSeal kit 28P (std) – NitrileSeal kit 28P (F3) – FluoroelastomerSeal kit 38P (std) – NitrileSeal Kit 38P (F3) – Fluoroelastomer

see table onnext page

S04350S04351S04352S04353S04354S04355

123

4

5

67

Index Description Part number

Parts List

6

7

2

1

5 4

High pressure filters

Element Service (cont.)

113

Replacement element part numbers

18P-1G04242G04243G04244G04245G04290G04291G04292G04293

18P-2G04250G04251G04252G04253G04298G04299G04300G04301

28P-1G04258G04259G04260G04261G04306G04307G04308G04309

28P-2G04266G04267G04268G04269G04314G04315G04316G04317

38P-1G04274G04275G04276G04277G04322G04323G04324G04325

38P-2G04282G04283G04284G04285G04330G04331G04332G04333

Model02Q05Q10Q20Q

02QH05QH10QH20QH

Elements with Nitrile seals

18P-1G04246G04247G04248G04249G04294G04295G04296G04297

18P-2G04254G04255G04256G04257G04302G04303G04304G04305

28P-1G04262G04263G04264G04265G04310G04311G04312G04313

28P-2G04270G04271G04272G04273G04318G04319G04320G04321

38P-1G04278G04279G04280G04281G04326G04327G04328G04329

38P-2G04286G04287G04288G04289G04334G04335G04336G04337

Model02Q05Q10Q20Q

02QH05QH10QH20QH

Elements with Fluoroelastomer seals

Ordering Information

Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.

Part number

18P110QBT1MG12118P110QBM3MG12118P120QBT1MG12118P120QBM3MG12118P210QBT1MG12118P210QBM3MG12118P220QBT1MG12118P220QBM3MG12128P110QBT1MG16128P110QBM3MG16128P120QBT1MG16128P120QBM3MG16128P210QBT1MG16128P210QBM3MG16138P110QBT1MG20138P110QBM3MG20138P120QBT1MG20138P120QBM3MG20138P210QBT1MG20138P210QBM3MG20138P220QBT1MG20138P220QBM3MG201

Supersedes

18P-1-10Q-TW6-98-B2B2-118P-1-10Q-M2-98-B2B2-118P-1-20Q-TW6-98-B2B2-118P-1-20Q-M2-98-B2B2-118P-2-10Q-TW6-98-B2B2-118P-2-10Q-M2-98-B2B2-118P-2-20Q-TW6-98-B2B2-118P-2-20Q-M2-98-B2B2-128P-1-10Q-TW6-98-C2C2-128P-1-10Q-M2-98-C2C2-128P-1-20Q-TW6-98-C2C2-128P-1-20Q-M2-98-C2C2-128P-2-10Q-TW6-98-C2C2-128P-2-10Q-M2-98-C2C2-138P-1-10Q-TW6-98-D2D2-138P-1-10Q-M2-98-D2D2-138P-1-20Q-TW6-98-D2D2-138P-1-20Q-M2-98-D2D2-138P-2-10Q-TW6-98-D2D2-138P-2-10Q-M2-98-D2D2-138P-2-20Q-TW6-98-D2D2-138P-2-20Q-M2-98-D2D2-1

Flow(l/min)

8080100100130130150150120120150150250250340340420420560560700700

Modelnumber

18P18P18P18P18P18P18P18P28P28P28P28P28P28P38P38P38P38P38P38P38P38P

Elementlength

Length 1Length 1Length 1Length 1Length 2Length 2Length 2Length 2Length 1Length 1Length 1Length 1Length 2Length 2Length 1Length 1Length 1Length 1Length 2Length 2Length 2Length 2

Mediarating (µ)

10102020101020201010202010101010202010102020

Seals

NitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrileNitrile

Indicator

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

ElectricalVisual

Bypasssettings

7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar7.0 bar

Replacementelements

G04244G04244G04245G04245G04252G04252G04253G04253G04260G04260G04261G04261G04268G04268G04276G04276G04277G04277G04284G04284G04285G04285

Ports

G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G3/4"G1"G1"G1"G1"G1"G1"

G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"G11/4"

Standard products table

Parker HannifinHydraulic Filter Division EuropeFDHB200UK. Section 14

114

High Pressure Filters

18/28/38P SeriesOrdering Information (cont.)

Product configuratorBox 1

Code12

LengthLength 1Length 2

Filter typeBox 2

38PBox 2

1Box 3

10QBox 4

BBox 5

M3Box 6

MBox 7

G20Box 8

1

CodeBV

Seal materialNitrileFluoroelastomer

Seal typeBox 4

Bypass valve3.5 bar7.0 barNo bypassNo bypass

Bypass and indicator settingsIndicator

2.5 bar5.0 bar5.0 bar

No indicator+ Box 8: code 2+ Box 8: code 2

CodeKMMX

Box 6

CodeN

M3T1PF1F2F3F4

No indicator portVisual indicatorElectrical indicatorPlugged with steel plugElectronic 4 LED, PNP, N.O.Electronic 4 LED, NPN, N.O.Electronic 4 LED, PNP, N.C.Electronic 4 LED, NPN, N.C.

IndicatorBox 5

Code12

OptionsStandardNo bypass

OptionsBox 8

Code18P28P38P

ModelSmall size high pressure filter, T-portMedium size high pressure filter, T-portLarge size high pressure filter, T-port

CodeBox 1

CodeG12S12M27H12F12G16S16M33H16F16G20G24S20S24M42M48H20F20

Ports18P: Thread G 3/4

Thread SAE 12Thread M27, ISO 6149SAE flange 3/4" 6000-MSAE flange 3/4" 6000

28P: Thread G 1Thread SAE 16Thread M33, ISO 6149SAE flange 1" 6000-MSAE flange 1" 6000

38P: Thread G 1 1/4

Thread G 1 1/2

Thread SAE 20Thread SAE 24Thread M42, ISO 6149Thread M48, ISO 6149SAE flange 1 1/4" 6000-MSAE flange 1 1/4" 6000

Filter connectionBox 7

Filter model18P-118P-228P-128P-238P-138P-2

Nominal flow (I/min) at viscosity 30 cSt02Q357080

140140320

05Q60

110100200220440

10Q80

130120250340560

20Q100150150300420700

Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection.Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for availability.

When filter includes a bypass valve but not an indicator,code denotes bypass setting.

Item is standardItem is standard green optionItem is semi standardItem is non standard

123123123123

Highlights Key (Denotes part number availability)

Note: Standard items are in stock, semi standard items are available within four weeks

Box 3

Element media

Microglass III elementHigh collapse element

20Q20QH

10Q10QH

05Q05QH

02Q02QH

Glass fibreMedia code

Degree of filtration

Average filtration beta ratio ß (ISO 16889) / particle size µm [c]

% efficiency, based on the above beta ratio (ßx)ßx(c)=2

50.0%N/AN/AN/A6

Degree of filtrationCode

ßx(c)=10

90.0%N/AN/A611

ßx(c)=75

98.7%N/A4.58.517

ßx(c)=100

99.0%N/A5918

ßx(c)=200

99.5%N/A61020

ßx(c)=1000

99.9%4.571222

02Q05Q10Q20Q

DisposableMicroglass III

02QH05QH10QH20QH

High collapseelement