DESCRIPTION
LMI system DS 60Electronic Control Systems :Load Moment IndicatorsTRANSCRIPT
![Page 1: LMI System DS 60](https://reader036.vdocuments.net/reader036/viewer/2022081803/5695d0d31a28ab9b029408ff/html5/thumbnails/1.jpg)
LMI system DS 60Electronic Control Systems:Load Moment Indicators
Hirschmann Automation and Control GmbH
Product descriptionType DS 60Description Load Moment Indicator for Telehandlers (Compact system)Product description The DS 60 load moment indicator system was designed especially for the use in
telehandlers. The complete control and display unit is built into a housing the sizeof a car radio, which can be inserted into the machines dashboard. All operatingdata can be displayed on the double line dot matrix display. CAN bus technology is used throughout the system, the advantages of which canbe found not only in the central unit, but in the sensor technology as well. Incomparison to conventional analogue technology, this technology provides addedsystem diagnostic possibilities which lead to shorter commissioning and servicetimes. A complete system consists of three components: The central unit, a length andangle sensor plus a four fold pressure transducer. Each system component is connected with each other via the CAN bus throughplug connectors. A PC with a windows tool is used to configure the DS 60 system. Using the configuration program, over 40 different extensions and up to 1000 loadcharts can be entered and stored in the system. The program is easy to use.Calibration is performed by using the console keys and menu guidance on thedisplay and without the need of additional tools. Access to the system software isprotected by a pin code.
Construction type In-dash housingOrder No. 606351 - 24 085 06 0002Technical dataStandards EN13000, EN50081-1, EN50081-2, EN60068-2-29, EN 60068-2-64Operating voltage 10 ... 36 V DCDisplay type DOT matrix LC 2x16 characters, 5mm, backlitInputs 4x digitalOutputs 4x digital, 2x relay contact (safety cut-off)Type of termination System plugInterface CAN-Bus, protocol CAN 2.0B, CANopen CiA DS 301, profile acc. to DS 401,
RS232 (for service)Environmental conditionsOperating temperature -25 to +75 °CStorage temperature -30 to +80 °CDegree of protection (IP) IP 65 (front side with sealing)Accessories
Angle sensor WG or length- /angle sensor LWG with CAN-Interface, pressuretransducer 2-or 4-fold with CAN-Interface
Wiring CAN bus cable 5m or 11m availableDrawing
page 1 of 2