lng ngl overview catalog

2
Analytically Accurate LNG & NGL Vaporization & Regulation cETLus Certified d Patented technology delivers a heated sample to the analytical device utilizing d existing power supplied by heat trace sample tubing Ensures optimal performance of gas analyzers d Maintains gas at least 30°F above the expected hydrocarbon dew point. d Rated for Class 1, Group D, Div 1 locations d cETLus Certified d Patented technology maintains heat at the sample point d Ensures optimal performance of gas analyzers d Maintains gas at least 30°F above the expected hydrocarbon dew point. d Rated for Class 1, Group D, Div 1 locations d Conforms to ASME B 31.3-2014 & ISO 8943-2007 d Includes NDE; Dye Penetrant (PT), Hydrotest, and PMI (if requested) d Fabricated to customer-specified metallurgy & rating d Stress analysis as part of design process d Suitable for LNG, LPG, & other process sampling d Can be utilized with the Pony® Probe Enclosure d Custom ANSI rating and length d Designed to ASME B31.3 for Pressure Piping d Rigid or Flexible Tubing Options d Prevents Pre-Vaporization d Multi-layered insulation d More efficient than conventional insulated lines d Maintenance-Free d Custom Project-Specific Designs d MODEL: P53 Remote, P53 Direct, Pony SCS, Custom designs within other enclosures MODEL: PONY, Pony SCS, Solar Powered Pony SCS, Certicollar® adaptors for use with multiple probe styles including the Mustang Certiprobe® Sample Extractor MODEL: MCP MODEL: VJTR, VJTF Mustang® P53 Sample Conditioning System (MSCS) Pony® Probe Enclosure Mustang Certiprobe® Sample Extractor Mustang® Vacuum Jacketed Tubing E N V I R O N M E N T A L L Y A W A R E P R O D U C T D O E S N O T V E N T N A T U R A L G A S

Upload: danielle-bergum

Post on 25-Jul-2016

257 views

Category:

Documents


5 download

DESCRIPTION

LNG & NGL Overview Catalog

TRANSCRIPT

Page 1: LNG NGL Overview Catalog

Analytically Accurate

LNG & NGL Vaporization & Regulation

cETLus Certified dPatented technology delivers a heated sample to the analytical device utilizing dexisting power supplied by heat trace sample tubingEnsures optimal performance of gas analyzers dMaintains gas at least 30°F above the expected hydrocarbon dew point. dRated for Class 1, Group D, Div 1 locations d

cETLus Certified dPatented technology maintains heat at the sample point dEnsures optimal performance of gas analyzers dMaintains gas at least 30°F above the expected hydrocarbon dew point. dRated for Class 1, Group D, Div 1 locations d

Conforms to ASME B 31.3-2014 & ISO 8943-2007 dIncludes NDE; Dye Penetrant (PT), Hydrotest, and PMI (if requested) dFabricated to customer-specified metallurgy & rating dStress analysis as part of design process dSuitable for LNG, LPG, & other process sampling dCan be utilized with the Pony® Probe Enclosure dCustom ANSI rating and length d

Designed to ASME B31.3 for Pressure Piping dRigid or Flexible Tubing Options dPrevents Pre-Vaporization dMulti-layered insulation dMore efficient than conventional insulated lines dMaintenance-Free dCustom Project-Specific Designs d

MODEL: P53 Remote, P53 Direct, Pony SCS, Custom designs within other enclosures

MODEL: PONY, Pony SCS, Solar Powered Pony SCS, Certicollar® adaptors for use with multiple probe styles including the Mustang Certiprobe® Sample Extractor

MODEL: MCP

MODEL: VJTR, VJTF

Mustang® P53 Sample Conditioning System (MSCS)

Pony® Probe Enclosure

Mustang Certiprobe® Sample Extractor

Mustang® Vacuum Jacketed Tubing

ENV

IRO

NM

ENTA

LLY AWARE

PRODUCT

DOES

NOT

VENT

NATURA

L

GA

S

Page 2: LNG NGL Overview Catalog

Conforms to ISO 8943;CSA Approved for New dBrunswick ProvidenceContinuous gas flow design eliminating post-vaporization hydrocarbon liquid ddropoutAccurate and reliable BTU measurements by your danalytical deviceSuitable for areas such as storage and transfer where redundancy is not a dconcernOptional software for operating, monitoring, trending, and reporting dATEX/IECEx Certifiable d

Conforms to ISO 8943;CSA Approved for New dBrunswick ProvidenceContinuous gas flow design eliminating post-vaporization hydrocarbon dliquid dropoutAccurate and reliable BTU measurements by your danalytical deviceOptional software for operating, monitoring, trending, and reporting dATEX/IECEx Certifiable d

Windows 2000 or XP Compatible dHistory & Real-Time Date Trending of Vaporizer during Load/Offload dLoad definition management with report spread sheets for vaporizer & dLNG dataConcurrent Interface up to 5 Vaporizers and Multiple GC Streams. dRS232, RS485, or IP Interface to Vaporizers for Monitoring and Upload dof Reports and Logs

MODEL: MIV-2-I ATEX/IECEx

MODEL: MV-AI, MV-C, MIV1-AI, MIV1-C, MIV2-AI, MIV2-C, MPRVSS, MPRVSSJR

MODEL: Single & Multi-Path Monitoring (SVM)

Mustang® Composite Sampling System

Mustang® Vaporizers

SoftView® Monitor Software

Locally Represented By:

MSB-LNGO VOL 1.2 ©2009-2015 MUSTANG SAMPLING, LLC. ALL RIGHTS RESERVED.

[email protected]

P 304-273-5357F 304-273-2531