2
FORMATION EVALUATION Resistivity Features Compensated for borehole effects (2 transmitters and 3 receivers) Electronics mounted in pad, near the antennas, for increased signal-to-noise ratio and higher operating range Borehole temperature sensor in pad allows real-time data correction Real-time speed correction Real-time indication of irregular tool motion, mud-cake build up, pad liſt off Back up arm can be replaced by an ML sensor e LOGIQ® High-Frequency Dielectric Tool is a pad-type device that uses a microwave signal of 1 gigahertz to measure the Bulk Volume of Water (BVW) in the flushed zone. In combination with other porosity devices, the BVW value helps to evaluate the amount of movable hydrocarbons in a reservoir. Also the high vertical tool resolution aids in the evaluation of thin beds. e design of the sensor, with two symmetric transmitters and 3 receivers, helps to minimize the effects of rugosity, borehole, and changes in readings due to pad contact. Also the pivot point is in the center of the pad to have a uniform pressure on the formation. Benefits Helps to evaluate the amount of movable hydrocarbons Aids in the evaluation of thin beds Effects of rugosity mudcake and pad contact have been minimized Performs in a wide range of borehole conditions Real-time temperature and speed corrections Applications Measures water saturation in the flushed zone (S xo ) In oil-based mud it measures irreducible water saturation (S WIRR ) Evaluation of thin beds Gas indicator Evaluation of cementation exponent “m” Resistivity (R xo ) and dielectric constant of the flushed zone Dielectric porosity LOGIQ ® High-Frequency Dielectric Tool HAL36338

Upload: others

Post on 17-May-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LOGIQ High-Frequency Dielectric Tool - Halliburton...Sales of Halliburton products and services will be in accord solely with the terms and conditions contained in the contract between

FORMATION EVALUATION

Resistivity

Features• Compensated for borehole effects (2 transmitters and

3 receivers)

• Electronics mounted in pad, near the antennas, for increasedsignal-to-noise ratio and higher operating range

• Borehole temperature sensor in pad allows real-time data correction

• Real-time speed correction

• Real-time indication of irregular tool motion, mud-cake build up, pad lift off

• Back up arm can be replaced by an ML sensor

The LOGIQ® High-Frequency Dielectric Tool is a pad-type devicethat uses a microwave signal of 1 gigahertz to measure the BulkVolume of Water (BVW) in the flushed zone. In combination withother porosity devices, the BVW value helps to evaluate theamount of movable hydrocarbons in a reservoir. Also the highvertical tool resolution aids in the evaluation of thin beds.

The design of the sensor, with two symmetric transmitters and 3receivers, helps to minimize the effects of rugosity, borehole, andchanges in readings due to pad contact. Also the pivot point is inthe center of the pad to have a uniform pressure on the formation.

Benefits• Helps to evaluate the amount of movable hydrocarbons

• Aids in the evaluation of thin beds

• Effects of rugosity mudcake and pad contact have been minimized

• Performs in a wide range of borehole conditions

• Real-time temperature and speed corrections

Applications• Measures water saturation in the flushed zone (Sxo)

• In oil-based mud it measures irreducible water saturation (SWIRR)

• Evaluation of thin beds

• Gas indicator

• Evaluation of cementation exponent “m”

• Resistivity (Rxo) and dielectric constant of the flushed zone

• Dielectric porosity

LOGIQ® High-Frequency Dielectric Tool

HA

L363

38

Page 2: LOGIQ High-Frequency Dielectric Tool - Halliburton...Sales of Halliburton products and services will be in accord solely with the terms and conditions contained in the contract between

FORMATION EVALUATION

www.halliburton.com

© 2011 Halliburton. All rights reserved. Sales of Halliburton products and services will be in accord solely with the terms and conditions contained in thecontract between Halliburton and the customer that is applicable to the sale. H07231 7/11

HA

L363

35

For more information, contact your Halliburton Wireline and Perforating representative.

Length (including electronics)

Weight

Maximum Pressure

Maximum Temperature

Operating Frequency

Logging Speed (recommended)(maximum)

Combinability

Minimum Hole

Maximum Hole

Mud Type

LOGIQ® High-Frequency Dielectric Tool

16.14 ft (4.91 m)

435 lb (197 kg)

20,000 psi (1,379 bar)

350°F (177°C)

1 Ghz

30 fpm (9 mpm)60 fpm (18 mpm)

LOGIQ Tools

5.5 in. (14 cm)

18.5 in. (47 cm)

Salt/Fresh/Oil

4.28 in.

129.85 in.Tool Length

22.5 in.Maximum Opening

37.09 in.HFDT™ Sensor

27.71 in.Temperature

Sensor

ML Pad

5.00 in.MaximumTool OD