lone star blower - fluid technology · 2016. 3. 17. · max100-c080 max100-c080 general performance...

2
Lone Star Blower Standard Specifications Materials of Construction Enclosure .................... Fabricated carbon steel Impeller ...................... 5 axis machined anodized 7075 aluminum Shaft ............................ Titanium alloy with Sm2CO17 magnets Casing.......................... A356 cast aluminum Bearing type ................ Journal style foil Bearings ...................... X-750 teflon coated Inconel Finish of enclosure ...... Powder coated Technical Data Outlet connection ........ 8ANSI #150 Blow off connection .... 5ANSI #150 Weight ........................ 1254 lbs. Maximum RPM ........... 33,400 Cooling ........................ Internally air cooled Temp range.................. 14°F to 104°F Sound level .................. 75 dB @ 3 feet free field Inlet filter ..................... ASHRAE Std. 52.1 Mounting ..................... Adjustable feet with anchor Electrical Data Motor type ................... Permanent magnet synchronous motor Insulation class ........... H Motor HP rating........... 100 Full load amps ............. 120 Voltage ........................ 460V, 3 PH, 60Hz VFD .............................. Yaskawa or KEB Controller .................... MI-COM processor (PLC optional) Communication ........... Ethernet, Modbus RTU, Modbus TCP, Hardwiring Options Dust tight/sealed enclosure High and low ambient temperature Separated electrical and mechanical enclosure Stainless steel enclosure Flanged intake connection Alternative voltage Outdoor enclosure Patents / Certifications Manufactured by TurboMax 10-0675821, 10-0781298, 10-0870887 CE-TUV K1747/E09, K1480/M09 UL-ULC 508A, 1446, 1004 ISO 9001 MAX100-C080 MAX100-C080 General Performance Standard Conditions (68°F, 36% RH, 14.7 psia) 16 14 12 10 8 6 4 2 0 System differential pressure - psi 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Flow at standard conditions – SCFM 120 80 40 0 Power – hp Max Power Max Flow Min Flow Min Flow Max Flow

Upload: others

Post on 15-Mar-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lone Star Blower - Fluid Technology · 2016. 3. 17. · MAX100-C080 MAX100-C080 General Performance Standard Conditions (68°F, 36% RH, 14.7 psia) 16 14 12 10 8 6 4 2 0 System differential

Lone Star Blower

Standard Specifications

Materials of ConstructionEnclosure .................... Fabricated carbon steelImpeller ...................... 5 axis machined anodized 7075 aluminumShaft ............................ Titanium alloy with Sm2CO17 magnetsCasing.......................... A356 cast aluminumBearing type ................ Journal style foilBearings ...................... X-750 teflon coated InconelFinish of enclosure ...... Powder coated

Technical Data

Outlet connection ........ 8” ANSI #150Blow off connection .... 5” ANSI #150Weight ........................ 1254 lbs.Maximum RPM ........... 33,400Cooling ........................ Internally air cooledTemp range.................. 14°F to 104°FSound level.................. 75 dB @ 3 feet free fieldInlet filter ..................... ASHRAE Std. 52.1Mounting ..................... Adjustable feet with anchor

Electrical Data

Motor type................... Permanent magnet synchronous motorInsulation class ........... HMotor HP rating........... 100Full load amps ............. 120Voltage ........................ 460V, 3 PH, 60HzVFD.............................. Yaskawa or KEBController .................... MI-COM processor (PLC optional)Communication ........... Ethernet, Modbus RTU, Modbus TCP,

Hardwiring

Options

Dust tight/sealed enclosureHigh and low ambient temperature Separated electrical and mechanical enclosureStainless steel enclosureFlanged intake connectionAlternative voltageOutdoor enclosure

Patents / Certifications

Manufactured by TurboMax 10-0675821, 10-0781298, 10-0870887CE-TUV K1747/E09, K1480/M09UL-ULC 508A, 1446, 1004ISO 9001

MAX100-C080

MAX100-C080

General Performance

Standard Conditions (68°F, 36% RH, 14.7 psia)

16

14

12

10

8

6

4

2

0

Syst

em d

iffer

entia

l pre

ssur

e - p

si

600 800 1000 1200 1400 1600 1800 2000 2200 2400

Flow at standard conditions – SCFM

120

80

40

0

Pow

er –

hp

Max Power

Max FlowMin Flow

Min Flow

Max Flow

Page 2: Lone Star Blower - Fluid Technology · 2016. 3. 17. · MAX100-C080 MAX100-C080 General Performance Standard Conditions (68°F, 36% RH, 14.7 psia) 16 14 12 10 8 6 4 2 0 System differential

LONE STAR BLOWER

+1 832 532 3112 +1 832 532 3115 Fax [email protected]

LSB0615

MAX100-C080 Discharge Size Blow-off Size Total Weight

8” 5” 1254 lbs.

Note: It is recommended that the blow off air discharge is piped to the outside using piping similar to Figure AA. The discharge air tempera-ture can reach a maximum of 175°F. Dimensions and specifications may change without notice.

BLOWERCONTROLLER

B

D

A

5" BLOW-OFF(BLOW-OFF AIR DISCHARGE)

E E

INLET LOUVER/AIR FILTER

POWER CABLE/GROUNDCABLE INLET

MCCB &HANDLE

8" ADAPTER

View D(right side)

View C(front side)

View A(rear side)

View E-E(top side) View B

(left side)