Page 1: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

LOW ENERGY HEATING & COOLINGThermally Activated Building Structures

Page 2: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

"A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

Anders Heating Limited

Page 3: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

Outdoor temperature

28C

Outdoor temperature

-2C

New commercial buildings are facing the combined challenge of meeting sustainability requirements and avoiding overheating whilst creating a comfortable environment for the occupants.

TABS uses a buildings concrete mass to store heat energy, allowing heating and cooling operations to be carried out at low-energy saving temperatures. It does this by circulating hot or cold water through REHAU PE-Xa pipes within the concrete slab of the building.

The slab effectively becomes a giant thermal accumulator extracting heat from the space in the day and cooling the building at night.

TABS cooling functionality

TABS heating functionality

WHAT IS TABS?Thermally Activated Building Structures

Page 4: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

University of Leicester, School of MedicineThe School of Medicine at the University of Leicester is the largest 'non - residential' project in the UK to have Passivhaus standard.

4

Page 5: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

WHAT ARE THE BENEFITS?A healthy climate

Thermally activated building structures have the following benefits:

- Low investment and operating costs

- "Comfort cooling" without draft effects

- Reduced air exchange in combination with ventilation systems

- No Sick Building Syndrome

- Use of renewable energy sources

- Low flow temperatures mean efficient performance of alternative energy sources

- Increased revenue by reducing required height per floor, allowing for the potential to add an additional floor

- Quick and easy installation

50%lower capacity operating costs

30%lower investment costs

AdvantagesApplications

Office Transport Hubs/ Stations

Retail Museums/ Galleries

Hospitals Sports center/ arena

Energy Saving Benefits

Air Conditioning

- Reduced air volumes when combined with TABS

so smaller plant and fan size required

- Reduced energy consumption

Chillers

- TABS uses closer to ambient temperatures (15-18°C)

versus typical chiller temperatures of 6-12°C

- This increases the COP of the chiller

5

Page 6: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

TABS works by using radiant heating & cooling to achieve more comfortable temperatures.

The thermal comfort of a person is determined by:

- The person’s activity- The person’s clothes- Air temperature - Air speed- Air humidity - Surface temperature

Radiant Heating and cooling benefit:- More energy efficient compared to air based systems- Higher comfort level for building occupants- Greater design freedom

- Reduced air movement (better for allergy suffers)- Low maintenance

The difference between air and radiant heating & cooling

AIR HEATING PERCEIVED TEMPERATURE:

18C RADIANT HEATING PERCEIVED TEMPERATURE:

20C

CONVECTIONTransfer of heat by air movement

CONDUCTIONTransfer of heat by surface contact

EVAPORATIONTransfer of heat by evapouration of water

RADIATIONTransfer of heat through electro maganetic radiation

Thermal loss and heat transfer in the human body

HOW DOES IT WORK?Radiant heating and cooling

SURFACE TEMPERATURE

AIR TEMPERATURE

18C

21C

AIR COOLING PERCEIVED TEMPERATURE:

25C RADIANT COOLING PERCEIVED TEMPERATURE:

25C

SURFACE TEMPERATURE

AIR TEMPERATURE

SURFACE TEMPERATURE

AIR TEMPERATURE

21C

15C

27C

24C

SURFACE TEMPERATURE

AIR TEMPERATURE

18C

21C

SURFACE TEMPERATURE

AIR TEMPERATURE

22C

27C

6

Page 7: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

"With the University keen to create a low carbon campus, REHAU TABS was the ideal choice"

Paul, Amroc Heating

7

Page 8: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

8

Page 9: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

OUR SYSTEM - PIPE AND FITTINGOver 750 million fi ttings manufactured worldwide

REHAU offer 3 main installation options for thermally activated building structures:

In-situ concrete slabs

- Large circuits possible- Minimal connections within structure- Around 300m2 installed per day (2 people)- Can sit anywhere within structural slab

Precast concrete planks

- Off site construction methods- Quick to install on site- Easy connections into building services- High cooling capacity of up to 90 W/m2

Pre-fabricated mesh

- Fast installation- Can be used for PT slab applications- Better outputs when near slab surface- Ideal for Tichelmann Loops- Two options available -

sTABS or TABS module

Beyond the REHAU PE-Xa pipe, the jointing system plays a central role.

Over 750 million fittings have been installed worldwide with NO LEAKS, REHAU EVERLOCTM consists of only 2 components making it the installers choice.

- Compression sleeve- Fitting

REHAU EVERLOCTM offers the following benefits:

- Fast and easy to install- No hot works on site, no mess- 10 year comprehensive warranty- No O-ring- Installation is immediately able to handle

pressure loads- REHAU fittings embedded in the concrete are

also convered by our comprehensive warranty

* Post and pre tension (PT) slabs and Hollow core slabs are also available

9

Page 10: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

Scoring a BREEAM ‘Very Good’ rating, the new Tate building is predicted to use 50% less energy than a typical gallery and generate 44% less carbon than current building regulations demand.

10

Page 11: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

CASE STUDIESSummary

University of Northampton

Type Education

Product TABS, PE-Xa pipe and fittings

Description 40,000m of pipework installed

School of Medicine, University of Leicester

Type Education

Product TABS, PE-Xa pipe and fittings

Description Leicester University’s new Centre for Medicine is the largest non-residential project in the UK to have been built to the Passivehaus standard

White Collar Factory

Type Offices

Product TABS, PE-Xa pipe and fittings

Description Over 150km of pipe installed across 15 floors

Tate Modern, London

Type Gallery

Product TABS, PE-Xa pipe and fittings

Description More than 24,000m of pipework installed with REHAU EVERLOCTM fittings

11

Page 12: LOW ENERGY HEATING & COOLING...LOW ENERGY HEATING & COOLING Thermally Activated Building Structures "A key reason for specification of REHAU TABS was the REHAU EVERLOCTM jointing system."

FOLLOW@ @REHAURenewables

CONNECTREHAU UK Ltd

The REHAU Docs App contains all relevant document about our systems. Whether you need brochures, technical information, installation instructions or a catalogue – the app provides fast access at any time. More information and download at: www.rehau.uk

Your REHAU sales office is happy to assist you:London, REHAU Ltd, The Building Centre, 25 Store Street, London WC1E 7BT Phone: 0207 580 6155 Fax: 0207 307 8595 Slough, Units 5 J & K, Langley Business Centre, Station Road, Langley, Slough SL3 8DS Phone: 01753 588500 Fax: 01753 588501 Manchester, Brinell Drive, Irlam, Manchester M44 5BL Phone: 0161 777 7400 Fax: 0161 777 7401 Glasgow, Phoenix House, Phoenix Crescent, Strathclyde Business Park, Bellshill, North Lanarkshire ML4 3NJ Phone: 01698 503700 Fax: 01698 503701 Dublin, 9 St. Johns Court, Business Park, Swords Road, Santry, Dublin 9 Phone: 00353 (0)1 8165020 Fax: 00353 (0)1 8165021

© REHAU LtdHill Court, Walford

Ross-on-WyeHerefordshire, HR9 5QN

www.rehau.uk

864839 EN 04.2018

WATCHREHAU Ltd