Page 1: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

OEM Component kits

Open panel versions

Low Pass Harmonic Filters

Enclosed versions

Low Pass Harmonic Filters—Type LPF Meet IEEE-519 Reduce Current and Voltage Distortion

Page 2: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Harmonics increase the KVA burden on transformers and generators. The higher the harmonic distortion, the higher the true rms current and KVA demand. Arteche Low Pass Harmonic Filters will help you to get the most out of existing transformers and generators. By reducing harmonic current distortion to negligible levels, current and KVA demand of existing loads are reduced, freeing up electrical system capacity. Standards: Type LPF Harmonic Filters meet the intent and requirements of IEEE-519, IEEE-1531, UL-508 and the CE Low Voltage Directive.

Mitigate Harmonics, Improve Total Power Factor and Meet IEEE-519!

Reduce transformer and motor temperature = Extend equipment life Reduce true rms and peak current = Eliminate disruptions caused by nuisance fuse and circuit breaker operation Reduce KVA demand = More power available from existing p power sources Reduce facility power loss = Energy cost savings Eliminate equipment interference = Improve equipment operation Improve total power factor = Reduce KVA consumption Improve productivity and profits!

Harmonic distortion reduces the total power factor, causes energy efficiency to suffer and thus reduces the available capacity of power sources such as transformers, generators and circuit conductors. As the percentage of non-linear load, connected to a transformer increases, the available KVA capacity decreases. Arteche LPF harmonic filters help to maximize the usable capacity of your power sources.

LPF Maximizes the Power Available from Transformers and Generators

Arteche Harmonic Filters Reduce KVA

Harmonic current distortion Harmonic voltage distortion Transformer over-loading Transformer over-heating Motor over-heating Nuisance fuse blowing Nuisance circuit breaker tripping Low total power factor Equipment interference Capacitor failure

Solve Harmonics Problems Right at Their Source

Benefits From using ARTECHE Type LPF Harmonic Filters

Problems Solved with ARTECHE Type LPF Harmonic Filters

Arteche Harmonic Filters Meet IEEE-519

Our LPF filters are suitable for: Diode converter with or without internal inductance SCR converter with or without internal inductance Variable or constant torque applications Non-Linear loads supplied from inverter power sources

2

No F ilte r W ith F ilte r

0 %

2 0 %

4 0 %

6 0 %

8 0 %

1 0 0 %

Cap

acity

1 .5 0 % 3 .0 0 % 5 .0 0 % 6 .2 5 %

T ra n sfo rm e r Im p e d a n ce

P o w e r S o u rce C a p a c i ty A va i la b lew h e n a l l lo a d s a re N o n -L in e a r

Page 3: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Current Distortion

ARTECHE standard Low Pass Harmonic Filters (designated as type KS) achieve full load input current distortion of 5% THD-i or less for six-pulse diode rectifiers. They can maintain distortion as low as 5% for the entire load range (0% to 100% load). The chart below illustrates filter performance, based upon circuit impedance and load conditions.

ARTECHE standard Low Pass Harmonic Filters (designated as Type KS) achieve input voltage distortion less than 2.25% THD-V, for six-pulse diode type rectifiers, for all load conditions (0% to 100%), with effective source impedance of 0.25% to 5%. Background voltage distortion, caused by other loads on the system may add to this level. Voltage Distortion vs. Impedance Total harmonic voltage distortion will be lowest for systems with low source impedance as demonstrated by the filter performance curves. Effective impedance (%Zeff) refers to the total source impedance relative to the actual load, as opposed to simple nameplate impedance values. A 500KVA transformer with 5% impedance, relative to a 50kVA load, has an effective impedance of 1%.

Current Distortion vs. Impedance Systems with high effective impedance (%Zeff), will have lower current distortion than a filter/drive applied on a low impedance (stiff) power source. This is demonstrated by the set of performance curves below. Effective impedance (%Zeff) refers to the total source impedance relative to the actual load, as opposed to simple nameplate impedance values. For example, a 500KVA transformer and rated 5% impedance, when considered relative to a 50kVA load, has an effective impedance of 1%. Effects of Unbalanced Line Voltage The existence of unbalanced line voltage can cause non-characteristic harmonics on the electrical system and will increase the residual total harmonic current distortion above the predicted values. Additionally, triplen harmonics (multiples of 3) which are normally not present in balanced three phase systems, may appear in unbalanced systems, adding to the residual harmonic current distortion. For best overall performance, the user should make every effort to balance the three line voltages.

% Harmonic Current Distortion vs. %ZeffStandard (KS) Version LPF

0

1

2

3

4

5

6

100%87.5%

75%62.5%

50%37.5%

30%25%

12.5%5%

% LOAD

% T

HD

-I

0.10% Zeff

0.25% Zeff

0.5% Zeff

1% Zeff

2% Zeff

3% Zeff

4% Zeff

5% Zeff

Effects of Unbalanced Line Voltage The existence of unbalanced line voltage may cause non-characteristic harmonics to be present on the system and will increase the residual total harmonic voltage distortion above the predicted values. Triplen harmonics, (those which are multiples of 3) which are normally not present in balanced three phase systems, may appear in unbalanced power systems, adding to the residual harmonic voltage distortion. The user should make every effort to balance the three line voltages.

% Harmonic Voltage Distortion vs. %Zeff

0

0.5

1

1.5

2

2.5

100%

87.5

%75

%

62.5

%50

%

37.5

%25

%

12.5

%

% LOAD

% T

HD

-V

0.25% Zeff

0.5% Zeff

1% Zeff

2% Zeff

2.5% Zeff

3% Zeff

4% Zeff

4.5% Zeff

5% Zeff

Harmonic Filter Performance

Voltage Distortion

3

Page 4: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Harmonic Spectrum Actual harmonic spectrum for a 6-pulse drive (VFD), operating at full load, and having an effective source impedance of 1% relative to the drive KVA rating. LPF filter reduced harmonic current distortion from about 75% to less than 5%.

Three Stages of Harmonic Filtering Our standard Low Pass Harmonic Filters (Type KS) offer three stages of filtering that nearly eliminate the harmonics commonly produced by three phase equipment using six pulse rectifiers. Our LPF filter is intended for adjustable speed drives, uninterruptible power supplies, and other rectifier controls, with any source impedance. 1) Input Stage The purpose of this stage is to isolate the LPF from other harmonics sources connected to the same power source and to prevent power system resonance. This stage also protects the load and filter capacitors against transients.

2) Output Stage The output stage contains a precise amount of impedance that minimizes the amount of harmonics produced by the load. It also reduces the harmonic burden placed on the shunt stage, and prevents resonance between the shunt stage and the load. 3) Shunt Stage The shunt stage absorbs residual harmonics remaining after both the input and output stages have played their roles in reducing load harmonics. Our basic three stage filter design achieves the lowest possible harmonic distortion levels while preventing power system resonance.

Three Stages of Harmonic Filtering

Comparison of Harmonic Distortion with and without ARTECHE Type LPF Filter

Motor drive (VFD) with Low Pass Filter (LPF) Actual THD-I is <5% (Nearly a sine wave)

Motor drive, no filter, and with 0.5% effective source impedance Actual THD-I = 100%

Motor drive, no filter, with line reactor 5% effective impedance Actual THD-I = 35%

Low Pass Filter THD-I is < 5%

No Filter THD-I = 100%

5% Line Reactor THD-I = 35%

0%

20%

40%

60%

80%

100%

Fund 5 7 11 13 17

Harmonic

TH

D-I

Without LPF

With LPF

Comparison of Actual Waveforms Reduce Harmonics

Improve Total Power Factor

Meet IEEE-519

Designed for Superior Performance

Arteche also produces Low Pass Harmonic Filters for 1-phase drives. Consult factory for details.

2 1

3

4

Page 5: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Your Choice of Two Filter Types

1. Standard Version Filters KS

Our standard Low Pass Harmonic Filter (Type KS) includes all three filter stages and achieves <5% THD-I (Total Harmonic Current Distortion) at virtually any load condition, when used in combination with a six pulse diode rectifier. It can also be used with phase controlled (SCR) rectifiers with excellent results. Our Standard (Type KS) Filter achieves 5% THD-I for VFD’s operating under any load condition and with any source impedance

Economical Solutions to Any Distortion Limit

The basic Low Pass Harmonic Filter (Type KB) includes two stages of filtering and takes advantage of pre-existing circuit inductance which may be in the form of either AC or DC reactors. It can also be used without external AC or DC reactors for those cases where the current distortion limit is above 5%. When the load (6-pulse diode rectifier) includes AC or DC reactors, Type KB filters will typically achieve distortion levels as low as 5% to 8% THD-i. Without additional AC or DC inductance, Type KB filters will achieve 8-12% THD-i.

2. Basic Version Filters KB

When to use KS or KB Version

Expected Distortion levels of Types KS and KB Filters

LPF Type VFD without AC or DC inductance

VFD with 5% AC Line Reactor

VFD with 3% DC Link Choke

KS Version < 5% THD-i < 5% THD-i < 5% THD-i

KB Version 8% - 12% THD-i 5% - 8% THD-i 5% - 8% THD-i

ISC / IL h < 11 11<h<17 17<h<23 23<h<35 35 < h TDD-I

< 20 4.0 2.0 1.5 0.6 0.3 5%

20 < 50 7.0 3.5 2.5 1.0 0.5 8%

50 < 100 10.0 4.5 4.0 1.5 0.7 12%

100 < 1000 12.0 5.5 5.0 2.0 1.0 15%

1000 up 15.0 7.0 6.0 2.5 1.4 20%

IEEE-519 Harmonic Limits

Use our basic filter (Type KB) to take advantage of internal inductance or for those applications where 8% or 12% distortion is acceptable.

Type KB when 8% or 12% distortion is acceptable

ARTECHE gives you two choices for Low Pass Harmonic Filter performance — Use our standard (Type KS) Low Pass Harmonic Filter, for guaranteed performance level of < 5% THD-i.

Type KS for < 5% THD-i

5

Page 6: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

ARTECHE will assemble and wire the complete filter onto an open construction back panel that you can mount into your own enclosure. Your choice of: 1. Single panel assembly (Caps & reactors) 2. Assembled capacitors on mounting plate (w/ furnished reactors loose for your own mounting)

2. Open Panel Assemblies

ARTECHE will completely assemble and wire the filter into a NEMA style enclosure of your choice. This version makes it convenient for you to drop ship a complete filter right to the job site. Standard enclosure types include: Nema 1 (indoors) Nema 3R (outdoors) Arteche will also supply filters in other enclosure styles. Call us for more information.

3. NEMA Style Enclosures (Nema 1, Nema 3R)

1. OEM Kits (individual components)

ARTECHE can provide OEM Kits that consist of the individual components that you can mount and wire in your own electrical enclosure. This is a very economical way to incorporate our filters directly into your drive cabinet. Both the KS and KB type filters are available as OEM Kits.

OEM Kits, Panel Assemblies, Nema Enclosed Filters

ARTECHE gives you the choice—use one of our fully assembled low pass harmonic filters or assemble and wire it yourself by using one of our Do-It-Yourself OEM kits. By using our OEM component kits, you gain total flexibility to adapt the filter to your available panel space.

Standard Configuration Alternatives

Filters That Meet Your Technical & Economic Needs

Capacitor cut-out contactor Filter bypass system VFD & filter combined bypass system Hybrid filters with PFC Others as required

Common Modifications Available

You can request Low Pass Harmonic Filters in various Nema style enclosures (N1, N3R, N12), as open panel assemblies, as OEM Kits, or in any other configuration that you need. Arteche can also produce custom filter designs to meet your special requirements, including bypass circuitry, capacitor cut-out contactors, and even medium voltage filters.

6

Page 7: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Product Specifications

Proprietary Reactor Design Reactors have a major influence over the performance of harmonic filters. Optimum performance of any harmonic filter demands accurate and balanced phase to phase inductance in all three reactor coils. Reactors used in ARTECHE filters have inductance balanced within 3% between all three phases. Our reactors utilize PolyGapTM core construction which strategically distributes the air gap into numerous tiny air gaps placed at precise locations within the core. The Poly-GapTM core construction achieves balanced phase inductance with negligible air gap (fringing) losses and virtually eliminates stray magnetic flux. Reactors used as part of the shunt stage include a temperature switch that may be used to send an alarm in the event the filter has been overloaded. Reactors used in Type LPF filters have been type tested with actual harmonic currents and are UL/CUL component recognized.

Exclusive Capacitor Design Capacitors are at the heart of any harmonic filter. With traditional filters, capacitors have been considered the weak link in a filter. ARTECHE capacitors are specially designed and constructed for harmonic filter applications. They are designed with a physical geometry that optimizes the dissipation of internal heat and achieves the lowest possible internal temperature. Although our capacitors are designed for operation at temperatures up to 85 degrees Celsius, the normal operating temperature of our Type LPF filters is much lower (typically 40C-60C) resulting in life expectancy as high as 1,000,000 hours of operation (at 40C). Capacitors used in ARTECHE Type LPF filters are UL/CUL component recognized.

Filter Specifications

System Voltage: 200, 208, 220, 240, 380, 400, 415, 440, 480, 600, 660, 690.

System Voltage tolerance: + / - 5%

System Voltage unbalance: up to 3% line voltage unbalance (note: THD-I will increase above normal levels when line voltage is unbalanced)

Frequency: 50HZ +/- 1Hz or 60hz, +/- 1hz available

Effective source impedance:

Utility - 0.1% to 6% => 3.5% to 5% voltage boost at output terminals

Generator - 10% to 15% => 6% to 8% voltage boost at output terminals

Loads: 6-pulse rectifier loads only; not for use with any linear loads

Service Factor: Voltage source inverters 1.0 x maximum ampere rating

Current source inverters 0.7 x maximum ampere rating

Power losses: 1% typical

Altitude: 1000 meters maximum

Relative Humidity: 95% maximum

Harmonics attenuated: 3rd – 50th

Residual harmonic current distortion: Type KS

Typical contribution of harmonic current distortion at full load is <5%THD-i.

Residual harmonic current distortion: Type KB when VFD has internal AC or DC reactor.

Contribution of harmonic current distortion at full load is typically 5%-8%THD-I; varies depending on the inductance of the internal reactor in the VFD.

Residual harmonic current distortion: Type KB without any AC or DC reactor

Contribution of harmonic current distortion at full load is 8%-12%THD-i.

IEEE – 519 Compliance: Guaranteed for all Isc/IL ratios when using “KS” version filter.

Voltage Regulation: + / - 5% (no load to full load)

Better by Design

Precision Reactors Harmonic Rated Capacitors

7

Page 8: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Type LPF filters are suitable for use with one or more 6-pulse type variable frequency drives (VFDs). Type LPF filters are not intended for use with linear loads (such as across-the-line started motors).

For variable torque applications: (Fans and pumps operated by variable frequency drives): Determine the total load (VFD) horsepower or KW rating. Select the appropriate filter based on the variable frequency drive (VFD) HP/KW and then confirm the total rated current is within the filter maximum current rating.

For constant torque applications (Non—fan and pump applications): Determine the maximum current requirement. Select the appropriate filter based on the maximum required current in amperes. Example: a 100HP, 480V, 124FLA drive, to be operated temporarily at 130% current requires a filter rated for at least 161 amps (use LPF 0125 480 KS).

For other applications: Consult factory for DC drive applications, other types of rectifiers, 50Hz ratings, single phase drives, other voltage ratings and higher load ratings. Consult factory for any other ratings or styles.

Basic OEM Kit

HP (VFD)

KW (VFD)

Max. Amps

Catalog Number

2 1.5 10.3 LPF 0002 240 50 KB

3 2.2 12.5 LPF 0003 240 50 KB

5 3.7 18 LPF 0005 240 50 KB

7.5 5.5 26 LPF 0008 240 50 KB

10 7.5 34 LPF 0010 240 50KB

15 11 52 LPF 0015 240 50 KB

20 15 69 LPF 0020 240 50 KB

25 18 87 LPF 0025 240 50 KB

30 22 103 LPF 0030 240 50 KB

40 30 129 LPF 0040 240 50 KB

50 37 164 LPF 0050 240 50 KB

60 45 190 LPF 0060 240 50 KB

75 55 242 LPF 0075 240 50 KB

100 75 311 LPF 0100 240 50 KB

125 93 388 LPF 0125 240 50 KB

150 112 448 LPF 0150 240 50 KB

200 150 604 LPF 0200 240 50 KB

1 0.75 5.2 LPF 0001 240 50 KB

1.5 1.1 7.8 LPF 001.5 240 50 KB

200 - 240 Volt, 50Hz Selection Tables

* insert “S” or “B” for KS or KB Type.

Standard OEM Kit

Nema 1 (Add “S” or “B”)

Nema 3R (Add “S” or “B”)

Open Panel (Add “S” or “B”)

Catalog Number

Catalog Number

Catalog Number

Catalog Number

LPF 0002 240 50 KS LPF 0002 240 50 K* N1 LPF 0002 240 50 K* N3R LPF 0002 240 50 K* OPN

LPF 0003 240 50 KS LPF 0003 240 50 K* N1 LPF 0003 240 50 K* N3R LPF 0003 240 50 K* OPN

LPF 0005 240 50 KS LPF 0005 240 50 K* N1 LPF 0005 240 50 K* N3R LPF 0005 240 50 K* OPN

LPF 0008 240 50 KS LPF 0008 240 50 K* N1 LPF 0008 240 50 K* N3R LPF 0008 240 50 K* OPN

LPF 0010 240 50 KS LPF 0010 240 50 K* N1 LPF 0010 240 50 K* N3R LPF 0010 240 50 K* OPN

LPF 0015 240 50 KS LPF 0015 240 50 K* N1 LPF 0015 240 50 K* N3R LPF 0015 240 50 K* OPN

LPF 0020 240 50 KS LPF 0020 240 50 K* N1 LPF 0020 240 50 K* N3R LPF 0020 240 50 K* OPN

LPF 0025 240 50 KS LPF 0025 240 50 K* N1 LPF 0025 240 50 K* N3R LPF 0025 240 50 K* OPN

LPF 0030 240 50 KS LPF 0030 240 50 K* N1 LPF 0030 240 50 K* N3R LPF 0030 240 50 K* OPN

LPF 0040 240 50 KS LPF 0040 240 50 K* N1 LPF 0040 240 50 K* N3R LPF 0040 240 50 K* OPN

LPF 0050 240 50 KS LPF 0050 240 50 K* N1 LPF 0050 240 50 K* N3R LPF 0050 240 50 K* OPN

LPF 0060 240 50 KS LPF 0060 240 50 K* N1 LPF 0060 240 50 K* N3R LPF 0060 240 50 K* OPN

LPF 0075 240 50 KS LPF 0075 240 50 K* N1 LPF 0075 240 50 K* N3R LPF 0075 240 50 K* OPN

LPF 0100 240 50 KS LPF 0100 240 50 K* N1 LPF 0100 240 50 K* N3R LPF 0100 240 50 K* OPN

LPF 0125 240 50 KS LPF 0125 240 50 K* N1 LPF 0125 240 50 K* N3R LPF 0125 240 50 K* OPN

LPF 0150 240 50 KS LPF 0150 240 50 K* N1 LPF 0150 240 50 K* N3R LPF 0150 240 50 K* OPN

LPF 0200 240 50 KS LPF 0200 240 50 K* N1 LPF 0200 240 50 K* N3R LPF 0200 240 50 K* OPN

LPF 0001 240 50 KS LPF 0001 240 50 K* N1 LPF 0001 240 50 K* N3R LPF 0001 240 50 K* OPN

LPF 001.5 240 50 KS LPF 001.5 240 50 K* N1 LPF 001.5 240 50 K* N3R LPF 001.5 240 50 K* OPN

8

Page 9: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Type LPF filters are suitable for use with one or more 6-pulse type variable frequency drives (VFDs). Type LPF filters are not intended for use with linear loads (such as across-the-line started motors).

For variable torque applications: (Fans and pumps operated by variable frequency drives): Determine the total load (VFD) horsepower or KW rating. Select the appropriate filter based on the variable frequency drive (VFD) HP/KW and then confirm the total rated current is within the filter maximum current rating.

For constant torque applications (Non—fan and pump applications): Determine the maximum current requirement. Select the appropriate filter based on the maximum required current in amperes. Example: a 100HP, 480V, 124FLA drive, to be operated temporarily at 130% current requires a filter rated for at least 161 amps (use LPF 0125 480 KS).

For other applications: Consult factory for DC drive applications, other types of rectifiers, 50Hz ratings, single phase drives, other voltage ratings and higher load ratings. Consult factory for any other ratings or styles.

208 - 240 Volt, 60Hz Selection Tables

* insert “S” or “B” for KS or KB Type.

Basic OEM Kit

HP (VFD)

KW (VFD)

Max. Amps

Catalog Number

1.5 1.1 7.8 LPF 001.5 240 KB

2 1.5 10.3 LPF 0002 240 KB

3 2.2 12.5 LPF 0003 240 KB

5 3.7 18 LPF 0005 240 KB

7.5 5.5 26 LPF 0008 240 KB

10 7.5 34 LPF 0010 240KB

15 11 52 LPF 0015 240 KB

20 15 69 LPF 0020 240 KB

25 18 87 LPF 0025 240 KB

30 22 103 LPF 0030 240 KB

40 30 129 LPF 0040 240 KB

50 37 164 LPF 0050 240 KB

60 45 190 LPF 0060 240 KB

75 55 242 LPF 0075 240 KB

100 75 311 LPF 0100 240 KB

125 93 388 LPF 0125 240 KB

150 112 448 LPF 0150 240 KB

200 150 604 LPF 0200 240 KB

Standard OEM Kit

Nema 1 (Add “S” or “B”)

Nema 3R (Add “S” or “B”)

Open Panel (Add “S” or “B”)

Catalog Number

Catalog Number

Catalog Number

Catalog Number

LPF 001.5 240 KS LPF 001.5 240 K* N1 LPF 001.5 240 K* N3R LPF 001.5 240 K* OPN

LPF 0002 240 KS LPF 0002 240 K* N1 LPF 0002 240 K* N3R LPF 0002 240 K* OPN

LPF 0003 240 KS LPF 0003 240 K* N1 LPF 0003 240 K* N3R LPF 0003 240 K* OPN

LPF 0005 240 KS LPF 0005 240 K* N1 LPF 0005 240 K* N3R LPF 0005 240 K* OPN

LPF 0008 240 KS LPF 0008 240 K* N1 LPF 0008 240 K* N3R LPF 0008 240 K* OPN

LPF 0010 240 KS LPF 0010 240 K* N1 LPF 0010 240 K* N3R LPF 0010 240 K* OPN

LPF 0015 240 KS LPF 0015 240 K* N1 LPF 0015 240 K* N3R LPF 0015 240 K* OPN

LPF 0020 240 KS LPF 0020 240 K* N1 LPF 0020 240 K* N3R LPF 0020 240 K* OPN

LPF 0025 240 KS LPF 0025 240 K* N1 LPF 0025 240 K* N3R LPF 0025 240 K* OPN

LPF 0030 240 KS LPF 0030 240 K* N1 LPF 0030 240 K* N3R LPF 0030 240 K* OPN

LPF 0040 240 KS LPF 0040 240 K* N1 LPF 0040 240 K* N3R LPF 0040 240 K* OPN

LPF 0050 240 KS LPF 0050 240 K* N1 LPF 0050 240 K* N3R LPF 0050 240 K* OPN

LPF 0060 240 KS LPF 0060 240 K* N1 LPF 0060 240 K* N3R LPF 0060 240 K* OPN

LPF 0075 240 KS LPF 0075 240 K* N1 LPF 0075 240 K* N3R LPF 0075 240 K* OPN

LPF 0100 240 KS LPF 0100 240 K* N1 LPF 0100 240 K* N3R LPF 0100 240 K* OPN

LPF 0125 240 KS LPF 0125 240 K* N1 LPF 0125 240 K* N3R LPF 0125 240 K* OPN

LPF 0150 240 KS LPF 0150 240 K* N1 LPF 0150 240 K* N3R LPF 0150 240 K* OPN

LPF 0200 240 KS LPF 0200 240 K* N1 LPF 0200 240 K* N3R LPF 0200 240 K* OPN

9

Page 10: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Type LPF filters are suitable for use with one or more 6-pulse type variable frequency drives (VFDs). LPF filters are not intended for use with linear loads (such as across-the-line started motors).

For variable torque applications (Fans and pumps operated by variable frequency drives): Determine the total load (VFD) horsepower or KW rating. Select the appropriate filter based on the variable frequency drive (VFD) HP/KW and then confirm the total rated current is within the filter full load current rating. Full Load Amps refers to the filter fundamental current rating.

For constant torque applications (Non—fan and pump applications): Determine the maximum current requirement. Select the appropriate filter based on the maximum required current in amperes. Example: a 100HP, 124FLA motor drive, to be operated temporarily at 130% over current requires a filter rated for at least 161 amps (LPF 0125 480 KS). Full Load Amps refers to the filter fundamental current rating.

For other applications: Consult factory for DC drive applications, other types of rectifiers, 50Hz ratings, single phase drives, other voltage ratings and higher load ratings. Consult factory or price list for enclosures.

380 - 415 Volt, 50Hz Selection Tables

* insert “S” or “B” for KS or KB Type.

Basic OEM Kit

HP (VFD)

KW (VFD)

Max. Amps

Catalog Number

3 1.5 6.4 LPF 0002 400 50 KB

4 3 8.0 LPF 0004 400 50 KB

5 3.7 13 LPF 0005 400 50 KB

7.5 5.5 18 LPF 0008 400 50 KB

10 7.5 24 LPF 0010 400 50 KB

15 11 29 LPF 0015 400 50 KB

20 15 37 LPF 0020 400 50 KB

25 18 46 LPF 0025 400 50 KB

30 22 58 LPF 0030 400 50 KB

40 30 70 LPF 0040 400 50 KB

50 37 81 LPF 0050 400 50 KB

60 45 98 LPF 0060 400 50 KB

75 55 135 LPF 0075 400 50 KB

100 75 169 LPF 0100 400 50 KB

125 93 203 LPF 0125 400 50 KB

150 112 277 LPF 0150 400 50 KB

200 150 323 LPF 0200 400 50 KB

250 186 393 LPF 0250 400 50 KB

300 225 462 LPF 0300 400 50 KB

350 261 532 LPF 0350 400 50 KB

400 300 599 LPF 0400 400 50 KB

450 336 647 LPF 0450 400 50 KB

500 375 786 LPF 0500 400 50 KB

600 450 923 LPF 0600 400 50 KB

700 525 1040 LPF 0700 400 50 KB

800 600 1179 LPF 0800 400 50 KB

900 670 1316 LPF 0900 400 50 KB

1000 750 1573 LPF 1000 400 50 KB

Standard OEM Kit

Catalog Number

LPF 0003 400 50 KS

LPF 0004 400 50 KS

LPF 0005 400 50 KS

LPF 0008 400 50 KS

LPF 0010 400 50 KS

LPF 0015 400 50 KS

LPF 0020 400 50 KS

LPF 0025 400 50 KS

LPF 0030 400 50 KS

LPF 0040 400 50 KS

LPF 0050 400 50 KS

LPF 0060 400 50 KS

LPF 0075 400 50 KS

LPF 0100 400 50 KS

LPF 0125 400 50 KS

LPF 0150 400 50 KS

LPF 0200 400 50 KS

LPF 0250 400 50 KS

LPF 0300 400 50 KS

LPF 0350 400 50 KS

LPF 0400 400 50 KS

LPF 0450 400 50 KS

LPF 0500 400 50 KS

LPF 0600 400 50 KS

LPF 0700 400 50 KS

LPF 0800 400 50 KS

LPF 0900 400 50 KS

Nema 1 (Add “S” or “B”)

Catalog Number

LPF 0002 400 50 K* N1

LPF 0004 400 50 K* N1

LPF 0005 400 50 K* N1

LPF 0008 400 50 K* N1

LPF 0010 400 50 K* N1

LPF 0015 400 50 K* N1

LPF 0020 400 50 K* N1

LPF 0025 400 50 K* N1

LPF 0030 400 50 K* N1

LPF 0040 400 50 K* N1

LPF 0050 400 50 K* N1

LPF 0060 400 50 K* N1

LPF 0075 400 50 K* N1

LPF 0100 400 50 K* N1

LPF 0125 400 50 K* N1

LPF 0150 400 50 K* N1

LPF 0200 400 50 K* N1

LPF 0250 400 50 K* N1

LPF 0300 400 50 K* N1

LPF 0350 400 50 K* N1

LPF 0400 400 50 K* N1

LPF 0450 400 50 K* N1

LPF 0500 400 50 K* N1

LPF 0600 400 50 K* N1

LPF 0700 400 50 K* N1

LPF 0800 400 50 K* N1

LPF 0900 400 50 K* N1

Nema 3R (Add “S” or “B”)

Catalog Number

LPF 0002 400 50 K* N3R

LPF 0004 400 50 K* N3R

LPF 0005 400 50 K* N3R

LPF 0008 00 500 K* N3R

LPF 0010 400 50 K* N3R

LPF 0015 400 50 K* N3R

LPF 0020 400 50 K* N3R

LPF 0025 400 50 K* N3R

LPF 0030 400 50 K* N3R

LPF 0040 400 50 K* N3R

LPF 0050 400 50 K* N3R

LPF 0060 400 50 K* N3R

LPF 0075 400 50 K* N3R

LPF 0100 400 50 K* N3R

LPF 0125 400 50 K* N3R

LPF 0150 400 50 K* N3R

LPF 0200 400 50 K* N3R

LPF 0250 400 50 K* N3R

LPF 0300 400 50 K* N3R

LPF 0350 400 50 K* N3R

LPF 0400 400 50 K* N3R

LPF 0450 400 50 K* N3R

LPF 0500 400 50 K* N3R

LPF 0600 400 50 K* N3R

LPF 0700 400 50 K* N3R

LPF 0800 400 50 K* N3R

LPF 0900 400 50 K* N3R

Open Panel (Add “S” or “B”)

Catalog Number

LPF 0002 400 50 K* OPN

LPF 0004 400 50 K* OPN

LPF 0005 400 50 K* OPN

LPF 0008 400 50 K* OPN

LPF 0010 400 50 K* OPN

LPF 0015 400 50 K* OPN

LPF 0020 400 50 K* OPN

LPF 0025 400 50 K* OPN

LPF 0030 400 50 K* OPN

LPF 0040 400 50 K* OPN

LPF 0050 400 50 K* OPN

LPF 0060 400 50 K* OPN

LPF 0075 400 50 K* OPN

LPF 0100 400 50 K* OPN

LPF 0125 400 50 K* OPN

LPF 0150 400 50 K* OPN

LPF 0200 400 50 K* OPN

LPF 0250 400 50 K* OPN

LPF 0300 400 50 K* OPN

LPF 0350 400 50 K* OPN

LPF 0400 4005 0 K* OPN

LPF 0450 400 50 K* OPN

LPF 0500 400 50 K* OPN

LPF 0600 400 50 K* OPN

LPF 0700 400 50 K* OPN

LPF 0800 400 50 K* OPN

LPF 0900 400 50 K* OPN

LPF 1000 400 50 KS LPF 1000 400 50 K* N1 LPF 1000 400 50 K* N3R LPF 1000 400 50 K* OPN

10

Page 11: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Type LPF filters are suitable for use with one or more 6-pulse type variable frequency drives (VFDs). Type LPF filters are not intended for use with linear loads (such as across-the-line started motors).

For variable torque applications: (Fans and pumps operated by variable frequency drives): Determine the total load (VFD) horsepower or KW rating. Select the appropriate filter based on the variable frequency drive (VFD) HP/KW and then confirm the total rated current is within the filter maximum current rating.

For constant torque applications (Non—fan and pump applications): Determine the maximum current requirement. Select the appropriate filter based on the maximum required current in amperes. Example: a 100HP, 480V, 124FLA drive, to be operated temporarily at 130% current requires a filter rated for at least 161 amps (use LPF 0125 480 KS).

For other applications: Consult factory for DC drive applications, other types of rectifiers, 50Hz ratings, single phase drives, other voltage ratings and higher load ratings. Consult factory for any other ratings or styles.

Basic OEM Kit

HP (VFD)

KW (VFD)

Max. Amps

Catalog Number

2 1.5 4.0 LPF 0002 480 KB

4 3 6.6 LPF 0004 480 KB

5 3.7 7.9 LPF 0005 480 KB

7.5 5.5 13 LPF 0007 480 KB

10 7.5 19 LPF 0010 480 KB

15 11 24 LPF 0015 480 KB

20 15 30 LPF 0020 480 KB

25 18 38 LPF 0025 480 KB

30 22 48 LPF 0030 480 KB

40 30 61 LPF 0040 480 KB

50 37 71 LPF 0050 480 KB

60 45 84 LPF 0060 480 KB

75 55 102 LPF 0075 480 KB

100 75 138 LPF 0100 480 KB

125 93 175 LPF 0125 480 KB

150 112 210 LPF 0150 480 KB

200 150 286 LPF 0200 480 KB

250 186 334 LPF 0250 480 KB

300 225 406 LPF 0300 480 KB

350 261 477 LPF 0350 480 KB

400 300 549 LPF 0400 480 KB

450 336 619 LPF 0450 480 KB

500 375 666 LPF 0500 480 KB

600 450 809 LPF 0600 480 KB

700 525 952 LPF 0700 480 KB

800 600 1071 LPF 0800 480 KB

1000 670 1251 LPF 0900 480 KB

Standard OEM Kit

Catalog Number

LPF 0002 480 KS

LPF 0004 480 KS

LPF 0005 480 KS

LPF 0007 480 KS

LPF 0010 480 KS

LPF 0015 480 KS

LPF 0020 480 KS

LPF 0025 480 KS

LPF 0030 480 KS

LPF 0040 480 KS

LPF 0050 480 KS

LPF 0060 480 KS

LPF 0075 480 KS

LPF 0100 480 KS

LPF 0125 480 KS

LPF 0150 480 KS

LPF 0200 480 KS

LPF 0250 480 KS

LPF 0300 480 KS

LPF 0350 480 KS

LPF 0400 480 KS

LPF 0450 480 KS

LPF 0500 480 KS

LPF 0600 480 KS

LPF 0700 480 KS

LPF 0800 480 KS

LPF 0900 480 KS

Nema 1 (Add “S” or “B”)

Catalog Number

LPF 0002 480 K* N1

LPF 0004 480 K* N1

LPF 0005 480 K* N1

LPF 0007 480 K* N1

LPF 0010 480 K* N1

LPF 0015 480 K* N1

LPF 0020 480 K* N1

LPF 0025 480 K* N1

LPF 0030 480 K* N1

LPF 0040 480 K* N1

LPF 0050 480 K* N1

LPF 0060 480 K* N1

LPF 0075 480 K* N1

LPF 0100 480 K* N1

LPF 0125 480 K* N1

LPF 0150 480 K* N1

LPF 0200 480 K* N1

LPF 0250 480 K* N1

LPF 0300 480 K* N1

LPF 0350 480 K* N1

LPF 0400 480 K* N1

LPF 0450 480 K* N1

LPF 0500 480 K* N1

LPF 0600 480 K* N1

LPF 0700 480 K* N1

LPF 0800 480 K* N1

LPF 0900 480 K* N1

Nema 3R (Add “S” or “B”)

Catalog Number

LPF 0002 480 K* N3R

LPF 0004 480 K* N3R

LPF 0005 480 K* N3R

LPF 0007 480 K* N3R

LPF 0010 480 K* N3R

LPF 0015 480 K* N3R

LPF 0020 480 K* N3R

LPF 0025 480 K* N3R

LPF 0030 480 K* N3R

LPF 0040 480 K* N3R

LPF 0050 480 K* N3R

LPF 0060 480 K* N3R

LPF 0075 480 K* N3R

LPF 0100 480 K* N3R

LPF 0125 480 K* N3R

LPF 0150 480 K* N3R

LPF 0200 480 K* N3R

LPF 0250 480 K* N3R

LPF 0300 480 K* N3R

LPF 0350 480 K* N3R

LPF 0400 480 K* N3R

LPF 0450 480 K* N3R

LPF 0500 480 K* N3R

LPF 0600 480 K* N3R

LPF 0700 480 K* N3R

LPF 0800 480 K* N3R

LPF 0900 480 K* N3R

Open Panel (Add “S” or “B”)

Catalog Number

LPF 0002 480 K* OPN

LPF 0004 480 K* OPN

LPF 0005 480 K* OPN

LPF 0007 480 K* OPN

LPF 0010 480 K* OPN

LPF 0015 480 K* OPN

LPF 0020 480 K* OPN

LPF 0025 480 K* OPN

LPF 0030 480 K* OPN

LPF 0040 480 K* OPN

LPF 0050 480 K* OPN

LPF 0060 480 K* OPN

LPF 0075 480 K* OPN

LPF 0100 480 K* OPN

LPF 0125 480 K* OPN

LPF 0150 480 K* OPN

LPF 0200 480 K* OPN

LPF 0250 480 K* OPN

LPF 0300 480 K* OPN

LPF 0350 480 K* OPN

LPF 0400 480 K* OPN

LPF 0450 480 K* OPN

LPF 0500 480 K* OPN

LPF 0600 480 K* OPN

LPF 0700 480 K* OPN

LPF 0800 480 K* OPN

LPF 0900 480 K* OPN

440 - 480 Volt, 60Hz Selection Tables

* insert “S” or “B” for KS or KB Type.

11

Page 12: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Type LPF filters are suitable for use with one or more 6-pulse type variable frequency drives (VFDs). Type LPF filters are not intended for use with linear loads (such as across-the-line started motors).

For variable torque applications: (Fans and pumps operated by variable frequency drives): Determine the total load (VFD) horsepower or KW rating. Select the appropriate filter based on the variable frequency drive (VFD) HP/KW and then confirm the total rated current is within the filter maximum current rating.

For constant torque applications (Non—fan and pump applications): Determine the maximum current requirement. Select the appropriate filter based on the maximum required current in amperes. Example: a 100HP, 124FLA drive, to be operated temporarily at 130% current requires a filter rated for at least 161 amps (LPF 0125 480 KS).

For other applications: Consult factory for DC drive applications, other types of rectifiers, 50Hz ratings, single phase drives, other voltage ratings and higher load ratings. Consult factory for any other ratings or styles.

600 Volt, 60Hz Selection Tables

* insert “S” or “B” for KS or KB Type.

Basic OEM Kit

HP (VFD)

KW (VFD)

Max. Amps

Catalog Number

3 2.2 4.5 LPF 0003 600 KB

5 3.7 7.6 LPF 0005 600 KB

7.5 5.5 9.0 LPF 0008 600 KB

10 7.5 12 LPF 0010 600 KB

15 11 19 LPF 0015 600 KB

20 15 23 LPF 0020 600 KB

25 18 26 LPF 0025 600 KB

30 22 34 LPF 0030 600 KB

40 30 45 LPF 0040 600 KB

50 37 57 LPF 0050 600 KB

60 45 64 LPF 0060 600 KB

75 55 76 LPF 0075 600 KB

100 75 113 LPF 0100 600 KB

125 93 132 LPF 0125 600 KB

150 112 151 LPF 0150 600 KB

200 150 208 LPF 0200 600 KB

250 186 246 LPF 0250 600 KB

300 225 303 LPF 0300 600 KB

350 261 340 LPF 0350 600 KB

400 300 416 LPF 0400 600 KB

450 336 454 LPF 0450 600 KB

500 375 492 LPF 0500 600 KB

600 450 605 LPF 0600 600 KB

700 525 719 LPF 0700 600 KB

800 600 794 LPF 0800 600 KB

1000 670 981 LPF 1000 600 KB

900 675 908 LPF 0900 600 KB

Standard OEM Kit

Nema 1 (Add “S” or “B”)

Nema 3R (Add “S” or “B”)

Open Panel (Add “S” or “B”)

Catalog Number

Catalog Number

Catalog Number

Catalog Number

LPF 0003 600 KS LPF 0003 600 K* N1 LPF 0003 600 K* N3R LPF 0003 600 K* OPN

LPF 0005 600 KS LPF 0005 600 K* N1 LPF 0005 600 K* N3R LPF 0005 600 K* OPN

LPF 0007 600 KS LPF 0007 600 K* N1 LPF 0008 600 K* N3R LPF 0008 600 K* OPN

LPF 0010 600 KS LPF 0010 600 K* N1 LPF 0010 600 K* N3R LPF 0010 600 K* OPN

LPF 0015 600 KS LPF 0015 600 K* N1 LPF 0015 600 K* N3R LPF 0015 600 K* OPN

LPF 0020 600 KS LPF 0020 600 K* N1 LPF 0020 600 K* N3R LPF 0020 600 K* OPN

LPF 0025 600 KS LPF 0025 600 K* N1 LPF 0025 600 K* N3R LPF 0025 600 K* OPN

LPF 0030 600 KS LPF 0030 600 K* N1 LPF 0030 600 K* N3R LPF 0030 600 K* OPN

LPF 0040 600 KS LPF 0040 600 K* N1 LPF 0040 600 K* N3R LPF 0040 600 K* OPN

LPF 0050 600 KS LPF 0050 600 K* N1 LPF 0050 600 K* N3R LPF 0050 600 K* OPN

LPF 0060 600 KS LPF 0060 600 K* N1 LPF 0060 600 K* N3R LPF 0060 600 K* OPN

LPF 0075 600 KS LPF 0075 600 K* N1 LPF 0075 600 K* N3R LPF 0075 600 K* OPN

LPF 0100 600 KS LPF 0100 600 K* N1 LPF 0100 600 K* N3R LPF 0100 600 K* OPN

LPF 0125 600 KS LPF 0125 600 K* N1 LPF 0125 600 K* N3R LPF 0125 600 K* OPN

LPF 0150 600 KS LPF 0150 600 K* N1 LPF 0150 600 K* N3R LPF 0150 600 K* OPN

LPF 0200 600 KS LPF 0200 600 K* N1 LPF 0200 600 K* N3R LPF 0200 600 K* OPN

LPF 0250 600 KS LPF 0250 600 K* N1 LPF 0250 600 K* N3R LPF 0250 600 K* OPN

LPF 0300 600 KS LPF 0300 600 K* N1 LPF 0300 600 K* N3R LPF 0300 600 K* OPN

LPF 0350 600 KS LPF 0350 600 K* N1 LPF 0350 600 K* N3R LPF 0350 600 K* OPN

LPF 0400 600 KS LPF 0400 600 K* N1 LPF 0400 600 K* N3R LPF 0400 600 K* OPN

LPF 0450 600 KS LPF 0450 600 K* N1 LPF 0450 600 K* N3R LPF 0450 600 K* OPN

LPF 0500 600 KS LPF 0500 600 K* N1 LPF 0500 600 K* N3R LPF 0500 600 K* OPN

LPF 0600 600 KS LPF 0600 600 K* N1 LPF 0600 600 K* N3R LPF 0600 600 K* OPN

LPF 0700 600 KS LPF 0700 600 K* N1 LPF 0700 600 K* N3R LPF 0700 600 K* OPN

LPF 0800 600 KS LPF 0800 600 K* N1 LPF 0800 600 K* N3R LPF 0800 600 K* OPN

LPF 0900 600 KS LPF 0900 600 K* N1 LPF 0900 600 K* N3R LPF 0900 600 K* OPN

LPF 1000 600 KS LPF 1000 600 K* N1 LPF 1000 600 K* N3R LPF 1000 600 K* OPN

12

Page 13: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Type LPF filters are suitable for use with one or more 6-pulse type variable frequency drives (VFDs). Type LPF filters are not intended for use with linear loads (such as across-the-line started motors).

For variable torque applications: (Fans and pumps operated by variable frequency drives): Determine the total load (VFD) horsepower or KW rating. Select the appropriate filter based on the variable frequency drive (VFD) HP/KW and then confirm the total rated current is within the filter maximum current rating.

For constant torque applications (Non—fan and pump applications): Determine the maximum current requirement. Select the appropriate filter based on the maximum required current in amperes. Example: a 100HP, 124FLA drive, to be operated tem-porarily at 130% current requires a filter rated for at least 161 amps (LPF 0125 480 KS).

For other applications: Consult factory for DC drive applications, other types of rectifiers, 50Hz ratings, single phase drives, other voltage ratings and higher load ratings. Consult factory for any other ratings or styles.

690 Volt, 50Hz Selection Tables

* insert “S” or “B” for KS or KB Type.

Basic OEM Kit

HP (VFD)

KW (VFD)

Max. Amps

Catalog Number

5 3.7 4.3 LPF 0005 690 50 KB

7.5 5.5 7.2 LPF 0008 690 50 KB

10 7.5 8.6 LPF 0010 690 50 KB

15 11 14.4 LPF 0015 690 50 KB

20 15 18 LPF 0020 690 50 KB

25 18 22 LPF 0025 690 50 KB

30 22 25 LPF 0030 690 50 KB

40 30 36 LPF 0040 690 50 KB

50 37 43 LPF 0050 690 50 KB

60 45 54 LPF 0060 690 50 KB

75 55 62 LPF 0075 690 50 KB

100 75 91 LPF 0100 690 50 KB

125 93 109 LPF 0125 690 50 KB

150 112 127 LPF 0150 690 50 KB

200 150 163 LPF 0200 690 50 KB

250 186 217 LPF 0250 690 50 KB

300 225 254 LPF 0300 690 50 KB

350 261 290 LPF 0350 690 50 KB

400 300 326 LPF 0400 690 50 KB

450 336 381 LPF 0450 690 50 KB

500 375 417 LPF 0500 690 50 KB

600 450 507 LPF 0600 690 50 KB

700 525 580 LPF 0700 690 50 KB

800 600 671 LPF 0800 690 50 KB

900 670 761 LPF 0900 690 50 KB

1000 750 834 LPF 1000 690 50 KB

1100 825 924 LPF 1100 690 50 KB

1200 900 1014 LPF 1200 690 50 KB

Standard OEM Kit

Nema 1 (Add “S” or “B”)

Nema 3R (Add “S” or “B”)

Open Panel (Add “S” or “B”)

Catalog Number

Catalog Number

Catalog Number

Catalog Number

LPF 0005 690 50 KS LPF 0005 690 50 K* N1 LPF 0005 690 50 K* N3R LPF 0005 690 50 K* OPN

LPF 0008 690 50 KS LPF 0008 690 50 K* N1 LPF 0008 69 500 K* N3R LPF 0008 690 50 K* OPN

LPF 0010 690 50 KS LPF 0010 690 50 K* N1 LPF 0010 690 50 K* N3R LPF 0010 690 50 K* OPN

LPF 0015 690 50 KS LPF 0015 690 50 K* N1 LPF 0015 690 50 K* N3R LPF 0015 690 50 K* OPN

LPF 0020 690 50 KS LPF 0020 690 50 K* N1 LPF 0020 690 50 K* N3R LPF 0020 690 50 K* OPN

LPF 0025 690 50 KS LPF 0025 690 50 K* N1 LPF 0025 690 50 K* N3R LPF 0025 690 50 K* OPN

LPF 0030 690 50 KS LPF 0030 690 50 K* N1 LPF 0030 690 50 K* N3R LPF 0030 690 50 K* OPN

LPF 0040 690 50 KS LPF 0040 690 50 K* N1 LPF 0040 690 50 K* N3R LPF 0040 690 50 K* OPN

LPF 0050 690 50 KS LPF 0050 690 50 K* N1 LPF 0050 690 50 K* N3R LPF 0050 690 50 K* OPN

LPF 0060 690 50 KS LPF 0060 690 50 K* N1 LPF 0060 690 50 K* N3R LPF 0060 690 50 K* OPN

LPF 0075 690 50 KS LPF 0075 690 50 K* N1 LPF 0075 690 50 K* N3R LPF 0075 690 50 K* OPN

LPF 0100 690 50 KS LPF 0100 690 50 K* N1 LPF 0100 690 50 K* N3R LPF 0100 690 50 K* OPN

LPF 0125 690 50 KS LPF 0125 690 50 K* N1 LPF 0125 690 50 K* N3R LPF 0125 690 50 K* OPN

LPF 0150 690 50 KS LPF 0150 690 50 K* N1 LPF 0150 690 50 K* N3R LPF 0150 690 50 K* OPN

LPF 0200 690 50 KS LPF 0200 690 50 K* N1 LPF 0200 690 50 K* N3R LPF 0200 690 50 K* OPN

LPF 0250 690 50 KS LPF 0250 690 50 K* N1 LPF 0250 690 50 K* N3R LPF 0250 690 50 K* OPN

LPF 0300 690 50 KS LPF 0300 690 50 K* N1 LPF 0300 690 50 K* N3R LPF 0300 690 50 K* OPN

LPF 0350 690 50 KS LPF 0350 690 50 K* N1 LPF 0350 690 50 K* N3R LPF 0350 690 50 K* OPN

LPF 0400 690 50 KS LPF 0400 690 50 K* N1 LPF 0400 690 50 K* N3R LPF 0400 690 50 K* OPN

LPF 0450 690 50 KS LPF 0450 690 50 K* N1 LPF 0450 690 50 K* N3R LPF 0450 690 50 K* OPN

LPF 0500 690 50 KS LPF 0500 690 50 K* N1 LPF 0500 690 50 K* N3R LPF 0500 690 50 K* OPN

LPF 0600 690 50 KS LPF 0600 690 50 K* N1 LPF 0600 690 50 K* N3R LPF 0600 690 50 K* OPN

LPF 0700 690 50 KS LPF 0700 690 50 K* N1 LPF 0700 690 50 K* N3R LPF 0700 690 50 K* OPN

LPF 0800 690 50 KS LPF 0800 690 50 K* N1 LPF 0800 690 50 K* N3R LPF 0800 690 50 K* OPN

LPF 0900 690 50 KS LPF 0900 690 50 K* N1 LPF 0900 690 50 K* N3R LPF 0900 690 50 K* OPN

LPF 1000 690 50 KS LPF 1000 690 50 K* N1 LPF 1000 690 50 K* N3R LPF 1000 690 50 K* OPN

LPF 1100 690 50 KS LPF 1100 690 50 K* N1 LPF 1100 690 50 K* N3R LPF 1100 690 50 K* OPN

LPF 1200 690 50 KS LPF 1200 690 50 K* N1 LPF 1200 690 50 K* N3R LPF 1200 690 50 K* OPN

13

Page 14: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Arteche offers complete technical support in several different formats.

Telephone support: 1-262-754-3883

Website support: www.artechepq.com

Email: [email protected]

Technical Support

TechNote Directory

TechNote # TechNote Description

TN-LPF-1 Theory of Operation—Low Pass Harmonic Filters TN-LPF-2 The Effects of Impedance on Harmonic Distortion TN-LPF-3 The Benefits of Using Type LPF Low Pass Harmonic Filters TN-LPF-4 Why do Arteche Low Pass Harmonic Filters Perform Better than Others? TN-LPF-5 Arteche Low Pass Harmonic Filters vs. 18-pulse TN-LPF-6 Voltage Distortion—Cause and Effect TN-LPF-7 Avoiding Harmonic Resonance with Low Pass Harmonic Filters TN-LPF-8 Derating Requirements for Harmonic Filters TN-LPF-9 Understanding IEEE-519 TN-LPF-10 Selecting Low Pass Harmonic Filters for DC Drives

Harmonic Analysis & Circuit Simulation

Arteche can perform harmonic analysis for either individual drives or for complete facilities, and will recommend the best economical solutions to meet your objectives. Our analysis is typically performed using ANSOFT Simplorer® Circuit Simulation software.

For the most accurate analysis please provide us with the following information. Single line electrical diagram with transformer KVA, voltage & impedance, Description of any problems, Provide any data you may have already collected, State your objectives (power quality, cost, etc)

C1

D1 D2 D3

D5 D6D4

L1

L2

L3

ET1

ET2

ET3

ICA:

CL

+

V VMdc

+

V VMab

kVA = xfmr kVA ratingZ = pu Z of xfmrVAC = secondary V of xfmrfreq = system freqhp = drive hp ratingpu_load = per unit load on drivCbus = 65uF x kWDCL = DC link choke

ARTECHE PQ, INC.Low Pass Harmonic Filter - Type K

kVA:=100

Z:=0.0575

Vac:=480

freq:=60

hp:=20

pu_load:=1.0

L7

L9

L10

L11L12 L13

C2

C3

C4

VMab.V [V] VMbc.V [V] VMac.V [V]

t [s ]

800.00

-800.00

0

-600.00

-400.00

-200.00

200.00

400.00

600.00

150.00m 200.00m160.00m165.00m170.00m175.00m180.00m185.00m190.00m

L1.I [A] AM1.I [A]

t [s ]

80.00

-80.00

0

-60.00

-40.00

-20.00

20.00

40.00

60.00

150.00m 200.00m160.00m165.00m170.00m175.00m180.00m185.00m190.00m

+

V VMbc

+

VVMac

LPF Input Current (Pea

Name ValueFFT_Probe1.A1 37.55FFT_Probe1.A3 54.20mFFT_Probe1.A5 303.77mFFT_Probe1.A7 921.03mFFT_Probe1.A9 20.99m

FFT_Probe1.A11 815.23mFFT_Probe1.A13 573.43mFFT_Probe1.A2 537.62m

FFT_Probe1.THD [%] 4.38FFT_Probe1.RMSAC 26.58

R1.I [A] 35.35

FFTProbe

FFT_Probe

DCL:=0

A

AM1

A

AM2

FF

TP

rob

e

FFT_Probe2

LPF Input Voltage

Name ValueFFT_Probe2.THD [%] 2.17FFT_Probe2.RMSAC 480.22

FFT_Probe2.A1 678.97FFT_Probe2.A2 4.05FFT_Probe2.A3 1.78FFT_Probe2.A5 3.09FFT_Probe2.A7 1.32FFT_Probe2.A9 0

FFT_Probe2.A11 0FFT_Probe2.A13 0

VMbc1.V [V] 620.23

R1

+

V VMbc1

L4

L5

L6

14

Published TechNotes

Application Engineers

Instruction Manual

General Data Sheets

Circuit Simulation of Low Pass Harmonic Filter - Type KS

Page 15: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Notes

15

Page 16: Low Pass Harmonic Filters - PWM Filters | APQ Power · Arteche Low Pass Harmonic Filters will help you to get ... roles in reducing load harmonics. Our basic three stage filter design

Contact ARTECHE PQ for solutions to Harmonic Distortion and Low Power Factor

Low Voltage, Medium Voltage and High Voltage Solutions

ARTECHE PQ, Inc. 16964 West Victor Road ● New Berlin, WI 53151 Phone: 1-262-754-3883 ● Fax: 1-262-754-3993 www.artechepq.com POWER QUALITY

Fixed Capacitor Systems

De-Tuned Capacitor

Active PF Compensation

Automatic Capacitors

Dynamic VAR Compensation

Soft Switching Capacitor Systems

Power Factor Improvement Low Pass Harmonic Filters (5%THD-i)

Tuned Harmonic Filters

Active Harmonic Filters

Automatic Harmonic Filters

12 & 18 Pulse Rectifier Upgrade Kits

Soft Switching Harmonic Filters

Harmonic Filters

Form No. C01-3005 / Jul 2009