SafeLine, Enclosed Switches

Low Voltage Products

Page 2: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

Enclosed Switches

SafeLine heavy-duty range is fully tested and designedto perform as:

• Safety switch• Local isolator• Main switch• Motor control switch• Maintenance switch• Emergency switch• Combination switch

Plastic enclosed SafeLine switches

• Enclosed load break switches, 16...800A• Enclosed switch fuses, 32...400A• IP65 polycarbonate enclosure• Self extinguish polycarbonate plastic material,flammability class UL 94: V-O

• Excellent impact resistance• Non toxic, halogen free material• Colour light grey

Steel sheet enclosed SafeLine switches

• Enclosed load break switches, 16...1600A• Enclosed switch fuses, 20...800A• Remark: SafeLine switches with power factorcorrection are also available

• IP54 and IP 65 enclosures• Mounting is very easy and simple with the new cableentries with ring-or C-flange openings. These entriesare used for fixing the enclosed switches.

• Colour light grey• Wide cabling space allows easy installation

Safe in use

• The handle can be padlocked with three padlocks inOFF- position thus preventing door opening and closingthe circuit in maintenance situations (ON-positionlocking on request)

• The door cannot be opened when the handle is in ON-position. This can be defeated by authorized personnelfor inspection.

• Reliable position indication. If the contacts are weldedtogether, the handle deviates from ON-position lessthan 45o.

Power factor correction

• When the power factor correction unit is located nearthe motor, it saves a lot of cables and reduces also thepower loss in the circuit

• SafeLine enclosed load break switches areavailable with power factor correction

The delivery of SafeLine switches includes

• Terminal bolt sets• Earthing and neutral terminals

SafeLine

Page 3: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

3ABB Control

New plastic enclosed load break switches

N

ABB

I ON

OOFF

• Pull stoppers fortwo rubber cablesin 16A enclosed switches

Easy to install

• Knock-out openings for M or Pg threads

on the top and bottom

• Terminals for 5-wiresystem: three phases +N + PE terminals

• Separate threaded knock-outopening for control wires onthe top and bottom

Easy to mount

• Optional sealingof the lid

• Auxiliary contactshave to be orderedseparately. Optionfor two early-breakauxiliary contacts

1 N.O. +1 N.C.2 N.O.2 N.C.

• Knock-out openingon the base forincoming cables

• Enclosure mountingscrews isolated fromthe inside housing

Features:• Material standards: IEC 529 and UL 50 for the enclosure• Standard IEC 947-3 for Switch-Disconnectors• European Standard EN60204 Safety of machinery• Cable outlets M or Pg sized threaded knock-outs• Also blank gland plates available• 3-, 4- and 6-pole versions• Handle indication O-I/ON-OFF

• IP65-rating• Suitable for 4- and 5-wire systems• The position indication is in all cases reliable.• It is not possible to lock a handle of an ABB-switch in

the O-position, unless the required isolation isensured.

Type OTP

5MN

D55

36

Page 4: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

4 ABB Control

Safety for personnel

• Door interlock inON-position

• Door interlockdefeatable (withrectangular handle)

• Cover cannot be removed if a handleis padlocked

ION

OOFF

ION

OOFF

ION

OOFF

OO

FF

I ON

OO

FF

I ON

ABB Control

ABB Control

Reliable position indication

Different handle types in OTP_ switches

• Three and four-pole isolationin same enclosure

The position of the handle indicates with complete reliability the exact position of the contactsin all circumstances. The switch mechanism is constructed so that the handle cannot indicatethe off position if one of the contacts has been welded together.

O O

FF

I ON

O O

FF

I ON

OO

FF

I ON

OO

FFI ON

• Padlocking with three padlocks against unintentionalstar-up. The handle can not be padlocked in the O-position if one of the contacts is not in the (OFF) -position.

OOFF

I ON

OOFF

I ON

Page 5: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

In steel enclosed switches both gland platescan be used for cabling. Either cable entries,with ring or C-flange openings can be chosen.Cable entries are also used for mounting theenclosed switches. Cable entries have "key-typeholes".The dividable cable entry solutions with ring flangeopenings permit bigger angles for cable installationthan before. The cable can be mounted at angles ofup to 13 degrees in relation to the cable inlet withno effect on the pull stopper.The cable is inserted via a knock-out or a ring-or a C-flange opening and it may be connectedby convenient Al/Cu clamps. There are severalconnection and cabling possibilities and cabling iseasy offering spacious room to work.

Wide cable mounting angle 13o

OT 16...125E• Cable knock-outs as standard,

compression glands have to beordered separately

• Earth and neutral terminalsincluded

• Knock-out for vent holes

Steel enclosed switches

Material and surface treatmentThe surface treatment of the steel enclosures is madeautomatically in the process. It includes 7-phases ofshower process to remove creases, zinc phosphatingas well as electrostatic powder coating.

• Painting systemSFS 5225 SP 60/1 ZnFo

• Sheet material ishot dip calvanised steel sheet

• PretreatmentZinc phoshating 1-2 g/m2

• PaintingElectrostatic powder coating,paint thickness 60 µm

• PaintPolyester powder coating

• Corrosion durabilityStandard ASTM M 117.Test duration is for thecoating 400 h

• Cable entries and flanges have to be orderedseparately, they are also used for fixing the switch

• Security latch in the door• Wide cabling space, cable clamps have to be

ordered separately• Earth and neutral terminals included

• StandardsLloyd's register of shipping.test requirements for thetype approval of control andelectrical equipment

OT 16...125E

OT 125A...1600

paintzincferro-zinc-alloysteel

Page 6: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

Requirements:One 630 A enclosed 3-pole load break switch, black handle, protection class IP 54, cable entries from top and bottom. One ingoing and oneoutgoing cable having diameter 43 mm.

Selection:Enclosed load break switch type: OT 630 KLAA3B

Enclosure accessories:

Enclosed Switches

Steel enclosed switches ordering examples

Alternative A:cable entries with ring-flangeopenings, size code ➁ OEZXP 24 R 2 pcsring-flanges OEZXR 150 2 pcs

OEZXR 037 6 pcs

Alternative B:cable entries with C-flangeopenings, size code ➁ OEZXP 240 C 2 pcsflange adapter OEZXC 1R 2 pcsring-flanges OEZXR 150 2 pcscover plate OEZXC 0 2 pcs

OEZXP 120OEZXP 240OEZXP 340OEZXP 280OEZXP 380

OEZXP 120COEZXP 240COEZXP 340COEZXP 280COEZXP 380C

OEZXP 24ROEZXP 34ROEZXP 28ROEZXP 38R

OEZXC 1R

OEZXC 0

OEZXC 2R

OEZXR 023,Knock-out Ø22,5 mmOEZXR 037,Knock-out Ø37 mmOEZXR 134 Ø22-35 mm

OEZXR 143 Ø31-44 mmOEZXR 150 Ø39-51 mmOEZXR 158 Ø46-59 mm

SafeLine

12345

2345

12345

Page 7: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Contents:

Technical data .................................................................................................................... 8

Ordering Information

Plastic enclosed load break switches, IP 65

- 3-pole ........................................................................................................................... 9

- 3-pole, installation switches ....................................................................................... 10

- 4-pole ......................................................................................................................... 10

- 6-pole ......................................................................................................................... 11

Steel sheet enclosed load break switches

- 3-pole, IP 54 .............................................................................................................. 12

- 3-pole, IP 65 ..................................................................................... ......................... 13

- 3-pole, change over switches .................................................................................... 14

Steel sheet enclosed load break switches

with capacitor for power factor correction ........................................................................ 15

Accessories, Auxiliary contacts ........................................................................................ 16

Dimension drawings ................................................................................................... 17-20

Enclosed switch fuses ................................................................................................ 21-30

Enclosure accessories ............................................................................................... 31-35

Ordering information for cable entries from bottom and 4-pole and 6-pole switches on request.

SafeLine

EnclosedLoad Break Switches

The technical data and dimensions are valid at the time of printing.We reserve the right to subsequent alternations.

Page 8: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesTechnical Data, according to IEC 947-3

Enclosed load break switch sizeOTP_/OT_ OT_

A 16 25 32 45 63 80 125E 125D 125 A

Rated insulation voltage and ratedoperational voltage AC20/DC20 Pollution degree 3 V 750 750 750 750 750 750 750 750 750

Rated thermal current and ratedoperational current AC20/DC20 / ambient 40°C A 25 32 40 50 63 80 125 125 135 / ambient 60°C A 25 32 40 50 63 80 125 100 125

Rated operational current, AC-21A and AC-22A up to 500 V A 16 25 32 45 63 80 125 125 125690 V A 16 25 32 45 63 63 125 80 125

Rated operational current, AC-23A up to 415 V A 16 20 23 30 38 55 90 75 105440 V A 16 20 23 30 32 51 78 60 90500 V A 16 20 23 30 32 32 70 56 70

690 V A 10 11 12 20 20 20 50 35 50

Rated fused short-circuit current rms. kA 50 50 50 50 50 50 50 50 50

…with back-up fuse size (IEC 408) A 25 32 40 50 63 80 125 125 200

Cable size* Cu-wire size suitable for terminal clamps mm 2 0,75-10 0,75-10 0,75-10 1,5-25 1,5-25 1,5-50 10-70 10-70 10-70OT OT OT OT OT OT OT OETL OT

Used switch type 16E_ 25E- 32E_ 45E_ 63E_ 80E_ 125E_ 125D_ 125A_

Enclosed load break switch sizeOT_

A 160 200 250 315 400 630 800 1000 1250 1600

Rated insulation voltage and ratedoperational voltage AC20/DC20 Pollution degree 3 V 750 1000 1000 1000 1000 1000 1000 1000 1000 1000

Rated thermal current and ratedoperational current AC20/DC20 / ambient 40°C In enclosure A 160 200 270 315 500 630 720 1000 1250 1600 / ambient 60°C In enclosure A 160 175 220 260 410 500 600 900 1000 1250..with minimum conductor cross section Cu mm 2 70 95 120 185 2x150 2x185 2x240 2x(60x5) 2x(80x5) 2x(100x5)

Rated operational current, AC-21A and AC-22A up to 500 V A 160 200 250 315 500 630 800 1000 1250 1600690 V A 160 200 250 315 500 630 800

1000 V A 200 250 250 400 400 400Rated operational current, AC-23A up to 415 V A 135 200 250 315 500 630 720 800 800 800

440 V A 125 200 250 315 500 590 670 800 800 800500 V A 125 200 250 315 500 580 600 800 800 800

690 V A 80 200 250 315 350 350 350

Rated fused short-circuit current rms. kA 50 100 100 100 100/50 80/50 80 50 50 50

…with back-up fuse size (IEC 408) A 250 400 400 400 400/630 630/800 800 800 1000 1250

Cable size* Cu-wire size suitable for terminal clamps Cu-wire size suitable for terminal clamps mm 2 10-70Terminal bolt size* Metric thread diameter x length mm 8x25 10x30 10x30 10x40 12x40 12x40 12x60 12x60 12x60

OT OETL OETL OETL OETL OETL OETL OETL OETL OETL

Used switch type 160E_ 200K_ 250K_ 315K_ 400D_ 630K_ 800K_ 1000K_ 1250K_ 1600K_* For load break switchMore information about load break switches, see our brochure OETL 1A GB

Page 9: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

1SCA022401R33501SCA022389R6880

1SCA022401R34301SCA022389R69601SCA022401R35101SCA022389R70001SCA022401R36001SCA022389R71801SCA022401R37801SCA022389R7260

1SCA022389R73401SCA022401R38601SCA022389R74201SCA022401R3940

Enclosed Load Break SwitchesOrdering Information

OTP 16B_

OTP 80...125B_

OTP 25...32B_

1SCA022383R26401SCA022383R25601SCA022389R84001SCA022389R75101SCA022383R30201SCA022383R29901SCA022383R34501SCA022383R3370

1SCA022389R76901SCA022401R31901SCA022383R37001SCA022401R3270

OTP 45...63B_

OTP 160...800

1SCA022278R70301SCA022278R15101SCA022278R21501SCA022278R27401SCA022278R33901SCA022278R39801SCA022303R0310

Plastic enclosed load break switches, grey enclosure,3-pole, IP65Cable entries from top and bottomType Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] / side W / H / DAC-22A AC-23A AC-23A [mm] [kg]≤500V ≤415V 500V

Includes selector type black handle (O-I and ON-OFF indication), N- and PE-terminals.In type OTP 16B3P includes also membrane cable glands (2 pcs) and pull stoppers (2 pcs).

OTP16B3M 16 16 16 2xM20 85 / 120 / 60 0.40 1SCA022383R2130OTP16B3P 16 16 16 2xPg16 85 / 120 / 60 0.40 1SCA022383R0940

Includes selector-type rectangular black handle (O-I and ON-OFF indication), N- and PE-terminals.Threaded knock-outs, compression glands have to be ordered separatelyOTP25B3M 25 20 20 2xM25 + M16 130 / 150 / 60 0.5OTP25B3P 25 20 20 2xPg21+Pg11 130 / 150 / 60 0.5OTP32B3M 32 23 23 2xM25 + M16 130 / 150 / 60 0.5OTP32B3P 32 23 23 2xPg21 + Pg11 130 / 150 / 60 0.5OTP45B3M 45 30 30 2xM32 + M16 145 / 200 / 90 0.9OTP45B3P 45 30 30 2xPg29 + Pg11 145 / 200 / 90 0.9OTP63B3M 63 38 32 2xM32 + M16 145 / 200 / 90 0.9OTP63B3P 63 38 32 2xPg29 + Pg11 145 / 200 / 90 0.9

Knock-out flanges, flanges have to be ordered separately

OTP80B3B 80 55 32 Flange I 200 / 400 / 140 2.40OTP80B3U 80 55 32 - 200 / 400 / 140 2.40OTP125B3B 125 90 70 Flange I 200 / 400 / 140 2.40OTP125B3U 125 90 70 - 200 / 400 / 140 2.40Includes selector-type rectangular red-yellow handle (O-I and ON-OFF indication), N- and PE- termi-nals. In type OTP 16BA3P includes also membrane cable glands, (2 pcs) and pull stoppers (2pcs).OTP16BA3M 16 16 16 2xM20 85 / 120 / 60 0.40OTP16BA3P 16 16 16 2xPg16 85 / 120 / 60 0.40Includes selector-type rectangular red-yellow handle (O-I and ON-OFF indication), N- and PE-terminals.Threaded knock-outs, compression glands have to be ordered separatelyOTP25BA3M 25 20 20 2xM25 + M16 130 / 150 / 60 0.50OTP25BA3P 25 20 20 2xPg21+Pg11 130 / 150 / 60 0.50OTP32BA3M 32 23 23 2xM25 + M16 130 / 150 / 60 0.50OTP32BA3P 32 23 23 2xPg21+Pg11 130 / 150 / 60 0.50OTP45BA3M 45 30 30 2xM32 + M16 145 / 200 / 90 0.90OTP45BA3P 45 30 30 2xPg29 + Pg11 145 / 200 / 90 0.90OTP63BA3M 63 38 32 2xM32 + M16 145 / 200 / 90 0.90OTP63BA3P 63 38 32 2xPg29 + Pg11 145 / 200 / 90 0.90

Knock-out flanges, flanges have to be ordered separately

OTP80BA3B 80 55 32 Flange I 200 / 400 / 140 2.40OTP80BA3U 80 55 32 - 200 / 400 / 140 2.40OTP125BA3B 125 90 70 Flange I 200 / 400 / 140 2.40OTP125BA3U 125 90 70 - 200 / 400 / 140 2.40

Includes pistol-type black handle (O-I and ON-OFF indication), N- and PE-terminals.

Knock-out flanges, flanges have to be ordered separately

OT160EFCC3B 160 135 125 Flange II 280 / 380 / 130 5.4OT200KFCC3B 200 200 200 Flange II 280 / 560 / 180 9OT250KFCC3B 250 250 250 Flange II 280 / 560 / 180 9OT315KFCC3B 315 315 315 Flange II 380 / 560 / 180 9OT400DFCC3B 400 400 400 Flange II 380 / 840 / 180 16OT630KFCC3B 630 630 580 Flange II 380 / 840 / 180 20OT800KFCC3B 720 720 600 2xFlange II 560 / 760 / 250 201) Other voltages up to 690V, see technical data, page 8.

See Enclosure Accessories, pages 31...35.

Page 10: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesOrdering Information

OTP 16H_

OTP 16...32B_

OTP 45...63B_

OTP 80...125B_

Plastic enclosed installation switches, whiteenclosure, 3-pole, IP65Cable entries from top and bottomType Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] / side W / H / DAC-22A AC-23A AC-23A [mm] [kg]≤500V ≤415V 500V

Includes white round handle (O-I and ON-OFF indication), N- and PE-terminals and in typeOTP 16HB3P membrane cable glands (2 pcs) and pull stoppers (2pcs).OTP16HB3M 16 16 16 2xM20 85 / 120 / 60 0.40 1SCA022401R2970OTP16HB3P 16 16 16 2xPg16 85 / 120 / 60 0.40 1SCA022389R6700OTP16HB3U 16 16 16 - 85 / 120 / 60 0.40 1SCA022401R3010

Plastic enclosed load break switches, grey enclosure,4-pole, IP65Cable entries from top and bottomType Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] / side W / H / DAC-22A AC-23A AC-23A [mm] [kg]≤500V ≤415V 500V

Includes selector-type rectangular black handle (O-I and ON-OFF indication), N- and PE-terminalsThreaded knock-outs, compression glands have to be ordered separatelyOTP16B4M 16 16 16 2xM25 + M16 130 / 150 / 60 0.60 1SCA022401R4160OTP16B4P 16 16 16 2xPg21+Pg11 130 / 150 / 60 0.60 1SCA022419R8620OTP25B4M 25 20 20 2xM25 + M16 130 / 150 / 60 0.60 1SCA022401R4320OTP25B4P 25 20 20 2xPg29 + Pg11 130 / 150 / 60 0.60 1SCA022401R4240OTP32B4M 32 23 23 2xM25 + M16 130 / 150 / 60 0.60 1SCA022401R4590OTP32B4P 32 23 23 2xPg21+Pg11 130 / 150 / 60 0.60 1SCA022401R4410OTP45B4M 45 30 30 2xM32 + M16 145 / 200 / 90 1.00 1SCA022401R4750OTP45B4P 45 30 30 2xPg29 + Pg11 145 / 200 / 90 1.00 1SCA022401R4670OTP63B4M 63 38 32 2xM32 + M16 145 / 200 / 90 1.00 1SCA022401R4910OTP63B4P 63 38 32 2xPg29 + Pg11 145 / 200 / 90 1.00 1SCA022401R4830Knock-out flanges, flanges have to be ordered separatelyOTP80B4B 80 55 32 Flange I 200 / 400 / 140 2.50 1SCA022401R5050OTP80B4U 80 55 32 - 200 / 400 / 140 2.50 1SCA022401R5130OTP125B4B 125 90 70 Flange I 200 / 400 / 140 2.50 1SCA022401R5210OTP125B4U 125 90 70 - 200 / 400 / 140 2.50 1SCA022401R5300

Includes selector-type rectangular red-yellow handle (O-I and ON-OFF indication), N- and PE-terminalsThreaded knock-outs, compression glands have to be ordered separatelyOTP16BA4P 16 16 16 2xPg21+Pg11 130 / 150 / 60 0.60 1SCA022401R4080OTP25BA4P 25 20 20 2xPg21+Pg11 130 / 150 / 60 0.70 1SCA022433R8140OTP32BA4P 32 23 23 2xPg21+Pg11 130 / 150 / 60 0.80 1SCA022433R8220

1) Other voltages up to 690V, see technical data, page 8.

See Enclosure Accessories, pages 31...35.

Page 11: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesOrdering Information

OTP 16...32B_

OTP 80...125B_

OTP 45...63B_

Plastic enclosed load break switches, grey enclosure,6-pole, IP65Cable entries from top and bottomType Rated 1) Cable outlets Enclosure Weight Ordering number

operational current [A] / side W / H / DAC 22A AC 23A AC 23A [mm] [kg]

≤500V ≤415V 500V

Includes selector-type rectangular black handle (O-I and ON-OFF indication), N- and PE-terminalsThreaded knock-outs, compression glands have to be ordered separatelyOTP16B6M 16 16 16 2xM25 + M16 130 / 150 / 85 0.70 1SCA022401R5560OTP16B6P 16 16 16 2xPg21+Pg11 130 / 150 / 85 0.70 1SCA022401R5480OTP25B6M 25 20 20 2xM25 + M16 130 / 150 / 85 0.70 1SCA022401R5720OTP25B6P 25 20 20 2xPg21 + Pg11 130 / 150 / 85 0.70 1SCA022401R5640OTP32B6M 32 23 23 2xM25 + M16 130 / 150 / 85 0.70 1SCA022401R5990OTP32B6P 32 23 23 2xPg21+Pg11 130 / 150 / 85 0.70 1SCA022401R5810

Includes pistol-type black handle (O-I and ON-OFF indication), N- and PE-terminalsThreaded knock-outs, compression glands have to be ordered separatelyOTP45B6M 45 30 30 2xM32 + M16 145 / 200 / 90 1.60 1SCA022401R6110OTP45B6P 45 30 30 2xPg29 + Pg11 145 / 200 / 90 1.60 1SCA022401R6020OTP63B6M 63 38 32 2xM32 + M16 145 / 200 / 90 1.60 1SCA022401R6370OTP63B6P 63 38 32 2xPg29 + Pg11 145 / 200 / 90 1.60 1SCA022401R6290Knock-out flanges, flanges have to be ordered separatelyOTP80B6B 80 55 32 Flange I 200 / 400 / 140 3.20 1SCA022401R6450OTP80B6U 80 55 32 - 200 / 400 / 140 3.20 1SCA022401R6530OTP125B6B 125 90 70 Flange I 200 / 400 / 140 3.20 1SCA022401R6610OTP125B6U 125 90 70 - 200 / 400 / 140 3.20 1SCA022401R6700

Includes selector-type rectangular red-yellow handle (O-I and ON-OFF indication), N- and PE-terminalsThreaded knock-outs, compression glands have to be ordered separatelyOTP16BA6M 16 16 16 2xM25 + M16 130 / 150 / 85 0.70 1SCA022401R6880OTP16BA6P 16 16 16 2xPg21+Pg11 130 / 150 / 85 0.70 1SCA022394R5330OTP25BA6M 25 20 20 2xM25 + M16 130 / 150 / 85 0.70 1SCA022401R6960OTP25BA6P 25 20 20 2xPg21+Pg11 130 / 150 / 85 0.70 1SCA022394R5410OTP32BA6M 32 23 23 2xM25 + M16 130 / 150 / 85 0.70 1SCA022401R7000OTP32BA6P 32 23 23 2xPg21+Pg11 130 / 150 / 85 0.70 1SCA022394R5680

Includes pistol-type red-yellow handle (O-I and ON-OFF indication), N- and PE-terminalsThreaded knock-outs, compression glands have to be ordered separatelyOTP45BA6M 45 30 30 2xM32 + M16 145 / 200 / 90 1.60 1SCA022401R7180OTP45BA6P 45 30 30 2xPg29 + Pg11 145 / 200 / 90 1.60 1SCA022394R5840OTP63BA6M 63 38 32 2xM32 + M16 145 / 200 / 90 1.60 1SCA022401R7260OTP63BA6P 63 38 32 2xPg29 + Pg11 145 / 200 / 90 1.60 1SCA022394R5760Knock-out flanges, flanges have to be ordered separatelyOTP80BA6B 80 55 32 Flange I 200 / 400 / 140 3.20 1SCA022401R7340OTP80BA6U 80 55 32 - 200 / 400 / 140 3.20 1SCA022401R7420OTP125BA6B 125 90 70 Flange I 200 / 400 / 140 3.20 1SCA022401R7510OTP125BA6U 125 90 70 - 200 / 400 / 140 3.20 1SCA022401R7690

1) Other voltages up to 690V, see technical data, page 8.

See Enclosure Accessories, pages 31...35.

Page 12: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Delivery without cable entries, top and bottom sides are open. Cable entries for C-flanges or forring-flanges have to be ordered separately, see accessories. These entries are used also for fixingthese enclosed switches. Flanges have to be ordered separately, too.Includes pistol type black handle (O-I and ON-OFF indication), N- and PE terminals.Type Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] per side W / H / DAC-22A AC-23A AC-23A Code for cable entry≤500V ≤415V 500V size, see accessories [mm] [kg]

OT125ALAA3B 125 105 70 250/400/180 10 1SCA022302R5910OT160ELAA3B 160 135 125 250/400/180 10 1SCA022280R3410OT200KLAA3B 200 200 200 400/600/230 17 1SCA022280R4060OT250KLAA3B 250 250 250 400/600/230 17 1SCA022280R4650OT315KLAA3B 315 315 315 400/600/230 17 1SCA022280R5200OT400DLAA3B 500 500 500 400/800/230 23 1SCA022279R9710OT630KLAA3B 630 630 580 400/1000/230 30 1SCA022280R0310OT800KLAA3B 720 720 600 400/1000/230 30 1SCA022280R0910OT1000KLAA3B 1000 800 800 800/1200/230 73 1SCA022370R3830OT1250KLAA3B 1250 800 800 800/1200/330 90 1SCA022350R0640OT1600KLAA3B 1600 800 800 800/1200/330 92 1SCA022437R8520

Enclosed Load Break SwitchesOrdering Information

OT 125A...1600

OT 16...125E

1 ... 5 see page 33

222222455

2) Only C-flanges available

Steel sheet enclosed load break switches,grey enclosure, 3-pole, IP54Cable entries from top and bottomType Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] / side W / H / D AC 22A AC 23A AC 23A

≤500V ≤415V 500V [mm] [kg]

Includes selector-type rectangular black handle (O-I and ON-OFF indication), N- and PE-terminals

Cable knock-outs as standard, compression glands have to be ordered separatelyOT16ELMM3B 16 16 16 2x∅20+∅16 162 / 240 / 110 1.6 1SCA022461R7960OT16ELPP3B 16 16 16 2x∅28,3+∅18,6 162 / 240 / 110 1.6 1SCA022461R8000OT25ELMM3B 25 20 20 2x∅25+∅16 162 / 240 / 110 1.6 1SCA022461R8180OT25ELPP3B 25 20 20 2x∅28,3+∅18,6 162 / 240 / 110 1.6 1SCA022461R8260OT32ELMM3B 32 23 23 2x∅25 + ∅16 162 / 240 / 110 1.6 1SCA022461R8340OT32ELPP3B 32 23 23 2x∅28,3 + ∅18,6 162 / 240 / 110 1.6 1SCA022461R8420OT45ELMM3B 45 30 30 2x∅32 + ∅16 162 / 240 / 110 2 1SCA022461R8510OT45ELPP3B 45 30 30 2x∅37 + ∅18,6 162 / 240 / 110 2 1SCA022461R8690OT63ELMM3B 63 38 32 2x∅32 + ∅16 162 / 240 / 110 2 1SCA022461R8770OT63ELPP3B 63 38 32 2x∅37 + ∅18,6 162 / 240 / 110 2 1SCA022461R8850

Cable knock-outs as standard, flanges have to be ordered separatelyOT80ELBB3B 80 55 32 Flange B 233 / 350 / 140 5 1SCA022461R8930OT125ELBB3B 125 90 70 Flange B 233 / 350 / 140 5 1SCA022461R9070

1 2)

1 2)

1) Other voltages up to 690V, see technical data, page 8.

See Enclosure Accessories, pages 31...35.

Page 13: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Delivery without cable entries, top and bottom sides are open. Cable entries for C-flanges or forring-flanges have to be ordered separately, see accessories. These entries are used also for fixingthese enclosed switches. Flanges have to be ordered separately, too.Includes pistol type black handle (O-I and ON-OFF indication), N- and PE terminals.Type Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] per side W / H / DAC-22A AC-23AAC-23A Code for cable≤500V ≤415V 500V entry size, [mm] [kg]

see accessories

OT125ALAA3BZ 125 105 70 250/400/180 10 1SCA022302R6710OT160ELAA3BZ 160 135 125 250/400/180 10 1SCA022302R7100 OT200KLAA3BZ 200 200 200 400/600/230 17 1SCA022302R7520OT250KLAA3BZ 250 250 250 400/600/230 17 1SCA022302R7950OT315KLAA3BZ 315 315 315 400/600/230 17 1SCA022302R8330OT400DLAA3BZ 500 500 500 400/800/230 23 1SCA022302R8760OT630KLAA3BZ 630 630 580 400/1000/230 30 1SCA022302R9140OT800KLAA3BZ 720 720 600 400/1000/230 30 1SCA022302R9570

Enclosed Load Break SwitchesOrdering Information

OT 125A...800

OT 16...125E

1 ... 2 see page 33

222

22

2

2) Only C-flanges available

Steel sheet enclosed load break switches,grey enclosure, 3-pole, IP65Cable entries from top and bottomType Rated 1) Cable outlets Enclosure Weight Ordering number

operational current [A] / side W / H / DAC-22A AC-23A AC-23A [mm] [kg]

≤500V ≤415V 500V

Includes selector-type rectangular black handle (O-I and ON-OFF indication), N-, PE-terminals

Cable knock-outs as standard, compression glands have to be ordered separatelyOT16ELMM3BZ 16 16 16 2x∅20+∅16 162 / 240 / 110 1.6 1SCA022461R9150OT16ELPP3BZ 16 16 16 2x∅28,3+∅18,6 162 / 240 / 110 1.6 1SCA022461R9230OT25ELMM3BZ 25 20 20 2x∅25+∅16 162 / 240 / 110 1.6 1SCA022461R9310OT25ELPP3BZ 25 20 20 2x∅28,3+∅18,6 162 / 240 / 110 1.6 1SCA022461R9400OT32ELMM3BZ 32 23 23 2x∅25+∅16 162 / 240 / 110 1.6 1SCA022461R9580OT32ELPP3BZ 32 23 23 2x∅28,3+∅18,6 162 / 240 / 110 1.6 1SCA022461R9660OT45ELMM3BZ 45 30 30 2x∅32+∅16 162 / 240 / 110 2 1SCA022461R9740OT45ELPP3BZ 45 30 30 2x∅37+∅18,6 162 / 240 / 110 2 1SCA022461R9820OT63ELMM3BZ 63 38 32 2x∅32+∅16 162 / 240 / 110 2 1SCA022461R9910OT63ELPP3BZ 63 38 32 2x∅37+∅18,6 162 / 240 / 110 2 1SCA022462R0080

Cable knock-outs as standard, flanges have to be ordered separatelyOT80ELBB3BZ 80 55 32 Flange B 233 / 350 / 140 5 1SCA022462R0160OT125ELBB3BZ 125 90 70 Flange B 233 / 350 / 140 5 1SCA022462R0240

1 2)

1 2)

1) Other voltages up to 690V, see technical data, page 8.

See Enclosure Accessories, pages 31...35.

Page 14: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Delivery without cable entries, top and bottom sides are open. Cable entries for C-flanges or forring-flanges have to be ordered separately, see accessories. These entries are used also for fixingthese enclosed switches. Flanges have to be ordered separately, too.Includes pistol type black handle (I-O-II indication), N- and PE terminals.Type Rated operational 1) Cable outlets Enclosure Weight Ordering number

current [A] per side W / H / DAC-22A AC-23A AC-23A Code for cable≤500V ≤415V 500V entry size, [mm [kg]

see accessories

OT125DLAA3C 125 75 56 250/400/180 11OT160ELAA3C 160 135 125 400/400/230 11OT200KLAA3C 200 200 200 800/600/230 31OT250KLAA3C 250 250 250 800/800/230 36OT315KLAA3C 315 315 315 800/800/230 36OT400DLAA3C 500 500 500 800/800/230 39OT630KLAA3C 630 630 580 800/1000/230 48OT800KLAA3C 720 720 600 800/1000/230 48

Enclosed Load Break SwitchesOrdering Information

OT 125...800

2) Only C-flanges available

IP 65 available, please complete the type number with code Z.Ordering example for IP 65 enclosure: OT 25ELPP3CZ

1 ... 4 see page 33

444

44

4

OT 25...63

1 2)

2 2)1SCA022280R19801SCA022280R21001SCA022280R23601SCA022280R25201SCA022280R27901SCA022280R29501SCA022280R31701SCA022389R8310

Steel sheet enclosed change-over switches,grey enclosure, 3-pole, IP54Cable entries from top and bottom

Type Rated operational 1) Cable outlets Enclosure Weight Ordering numbercurrent [A] / side W / H / D

AC-22A AC-23AAC-23A [mm] [kg≤500V ≤415V 500V

Includes pistol-type rectangular black handle (I-O-II indication), N- and PE-terminalsCable knock-outs as standard, compression glands have to be ordered separately

OT16ELMM3C 16 16 16 2x∅25+∅16 233 / 350 / 140 1.9 1SCA022473R1070OT16ELPP3C 16 16 16 2x∅28,3+∅18,6 233 / 350 / 140 1.9 1SCA022473R1310OT25ELMM3C 25 20 20 2x∅25+∅16 233 / 350 / 140 1.9 1SCA022473R1580OT25ELPP3C 25 20 20 2x∅28,3+∅18,6 233 / 350 / 140 1.9 1SCA022473R1740OT32ELMM3C 32 23 23 2x∅25 + ∅16 233 / 350 / 140 1.9 1SCA022473R1910OT32ELPP3C 32 23 23 2x∅28,3 + ∅18,6 233 / 350 / 140 1.9 1SCA022473R2120OT45ELMM3C 45 30 30 2x∅32 + ∅16 233 / 350 / 140 4 1SCA022473R2390OT45ELPP3C 45 30 30 2x∅37 + ∅18,6 233 / 350 / 140 4 1SCA022473R2550OT63ELMM3C 63 38 32 2x∅32 + ∅16 233 / 350 / 140 4 1SCA022473R2710OT63ELPP3C 63 38 32 2x∅37 + ∅18,6 233 / 350 / 140 4 1SCA022473R2980

1) Other voltages up to 690V, see technical data, page 8.

See Enclosure Accessories, pages 31...35.

Page 15: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesOrdering Information

OT 125 ... 630

Steel sheet enclosed load break switches with capacitorfor power factor correction, IP54, 3 pole

Cable entry from bottom

REMARKS: The switches are delivered without cable entry on bottom side, it is open. Cable entry for C-flanges or for ring-flanges has to be ordered separately, see accessories. The entry is used also for fixingthe enclosed switch. Flanges for the entry have to be ordered separately, too. Includes black handle withI-0/ON-OFF indication.

Type For Capacitor Voltage Size code Weight Ordering numbermotor size for theoutput cable entry[kW] [kvar] [V] [kg]

OT 125 DBUA3F-15/400 30/37 15 400 23 1SCA022280R3330OT 125 DBUA3F-15/500 30/37 9 500 23 1SCA022280R3500OT 125 DBUA3F-15/690 30 15 690 23 1SCA022280R3760

OT 200 KAUA3F-20/400 45/55 20 400 39 1SCA022280R3920OT 200 KAUA3F-20/500 45/55 18 500 39 1SCA022280R4140OT 200 KAUA3F-20/690 45/55 20 690 39 1SCA022280R4310

OT 200 KAUA3F-30/400 75 30 400 42 1SCA022280R4570OT 200 KAUA3F-30/500 75 27 500 42 1SCA022280R4730OT 200 KAUA3F-30/690 75 30 690 42 1SCA022280R4900

OT 200 KAUA3F-40/400 90 40 400 44 1SCA022280R5110OT 200 KAUA3F-40/500 90 36 500 44 1SCA022280R5380OT 200 KAUA3F-40/690 90 40 690 44 1SCA022280R5540

OT 250 KAUA3F-40/400 110 40 400 44 1SCA022280R5710OT 250 KAUA3F-40/500 110 36 500 44 1SCA022280R5890OT 250 KAUA3F-40/690 110 40 690 44 1SCA022280R6010

OT 250 KAUA3F-60/400 132 60 400 57 1SCA022280R6270OT 250 KAUA3F-60/690 132 60 690 57 1SCA022280R6600

OT 400 DAUA3F-60/400 160 60 400 66 1SCA022280R6860OT 400 DBUA3F-60/500 160 54 500 66 1SCA022280R7080OT 400 DAUA3F-60/690 160 60 690 66 1SCA022280R7240

OT 400 DBUA3F-80/400 200 80 400 71 1SCA022280R7410OT 400 DBUA3F-80/500 200 72 500 71 1SCA022280R7670OT 400 DBUA3F-80/690 200 80 690 71 1SCA022280R7830

OT 630 KAUA3F-100/400 250 100 400 94 1SCA022280R8050OT 630 KAUA3F-100/690 250 100 690 94 1SCA022280R8480

OT 630 KAUA3F-120/400 315 120 400 98 1SCA022280R8640OT 630 KAUA3F-120/690 315 120 690 98 1SCA022280R9020

2

2

2

2

2

2

4

4

4

4

See enclosure accessories pages 31...35.

2 ... 4 see page 33.

2

2

Page 16: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineAccessories, Auxiliary ContactsOrdering Information

Type2) Description Performance Ie 1) For safety Package Ordering number

3) Ue AC 12 DC 12 switch [pc]

OBEA 10OBEA 10 AU

10

OBEA 01OBEA 01 AU

OZXK 13 OT 200_...315_ 1

OZXK 2 OT 400_...1600_ 1

OZXK 14 OT 200_...315_ 1

OZXK 4 OT 400_...1600_ 1

OZXK 15 OT 200_...315_ 1

OZXK 5 OT 400_...1600_ 1

2no

4no

1 no

1 n c

120V 8A -125V - 1.1A240V 6A -250V - 0.55A400V 4A -415V 4A -440V - 0.31A480V 3A -500V 3A 0.27A600V - 0.2A690V 2A -

2no+2nc

OT 125A...160_

Auxiliary contacts for enclosed load break switches OT125A...1600

Technical data of OBEA and OZXK_ auxiliary contacts:- Cable cross section min 0.5 mm2, max. 2 x 2.5 mm2

- Insulation voltage 690 V- Rated thermal current Ith = 10 A

1) According to IEC 947-5-12) Types AU_ for extremely difficult circumstances, even at low voltages. The

contacts are gold plated.3) Contact numbering according to EN 50013.

Remarks:- the n.o. auxiliary contacts break before the main contacts open.

OZXK_mounting to the switches OT 200_...630_

OA1G01OA1G10

-mountingto the leftside

-mountingto the rightside

1) Not suitable for OT63D_

Technical data of OA_auxiliary contacts:- Cable cross section. max. 2 x 2.5 mm2

- Rated thermal current Ith = 16 A- Operational currents Ie, AC 15 (IEC 947-5-1) = 230V/6A, 400V/4A, 415V/4A, 690V/2A

13

14

21

22

1SCA022190R30001SCA022185R3310

1SCA022190R32601SCA022185R3730

1SCA022144R7230

1SCA022131R8850

1SCA022144R7580

1SCA022131R9230

1SCA022144R7310

1SCA022131R9400

1SCA022353R4970

1SCA022353R4890

21

22

1nc

Protection degree IP20.

OBEA_

Auxiliary contacts for enclosed load break switches OTP_ and OT16...125ERemarks: the no auxiliary contacts break before the main contacts open - "early break"

Type Description For Weight /pc Package Ordering numberswitches [kg] [pc]

OA 1G10 1no OTP_ 0.03 10

OA 1G01 1nc OT16...125E1) 0.03 101no

13

14

Page 17: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

17

SafeLine

ABB Control

Type E W H D A B ∅∅∅∅G X Y3 - p o l eOTP 25…32_3M 33 130 150 60 115 136 5 2x∅25+M16 2x∅29+∅19

OTP 25…32_3P 33 130 150 60 115 136 5 2xPg21+Pg11 2x∅29+∅19

OTP 45…63_3M 33 145 200 90 129.5 182.5 5 2x∅32+M16 2x∅38+∅19OTP 45…63_3P 33 145 200 90 129.5 182.5 5 2xPg29+Pg11 2x∅38+∅19OTP 80…125_3B 33 200 400 140 176 376 6 I-flange blancoOTP 80…125_3U 33 200 400 140 176 376 6 blanco blanco

4 - p o l eOTP 16…32_4M 33 130 150 60 115 136 5 2x∅25+M16 2x∅29+∅19OTP 25…32_4P 33 130 150 60 115 136 5 2xPg21+Pg11 2x∅29+∅19

OTP 45…63_4M 33 145 200 90 129.5 182.5 5 2x∅32+M16 2x∅38+∅19OTP 45…63_4P 33 145 200 90 129.5 182.5 5 2xPg29+Pg11 2x∅38+∅19OTP 80…125_4B 33 200 400 140 176 376 6 I-flange blancoOTP 80…125_4U 33 200 400 140 176 376 6 blanco blanco

6 - p o l eOTP 16…32_6M 33 130 150 85 115 136 5 2x∅25+M16 2x∅29+∅19

OTP 16…32_6P 33 130 150 85 115 136 5 2xPg21+Pg11 2x∅29+∅19OTP 45…63_6M 45 145 200 90 129.5 182.5 5 2x∅32+M16 2x∅38+∅19

OTP 45…63_6P 45 145 200 90 129.5 182.5 5 2xPg29+Pg11 2x∅38+∅19OTP 80…125_6B 45 200 400 140 176 376 6 I-flange blancoOTP 80…125_6U 45 200 400 140 176 376 6 blanco blanco

Enclosed Load Break SwitchesDimension Drawings

OO

FF

I ON

120

85

60

33

X

X

71

106

ø5

OTP 16H3_Ø23

S006

99A

ABB Control

X

OTP 16H3 M1 2xM20OTP 16 H3 P1 2xPg16

Plastic enclosed load break switches

O O

FF

I ON

120

85

60

33

X

X

70.5

105.5

ø5

OTP 16 B3_Ø23

S01

000A

X

OTP 16 B3 M 2xM20OTP 16 B3 P 2xPg16OTP 16 B3 U -

O O

FF

I ON

H

W

D

33

X

X

E

F

øG134

120±0.2

33

31

30±0.2

118

7

Ø7±0,5

47B-flange

Y

S010

01A

Page 18: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesDimension Drawings

Plastic enclosed load break switches

Metal enclosed load break switches

Enclosed Load Break Switch Size

Cable entry / side

Type H / mm W /mm D / mm E / mm A / mm B / mm X / YOT 16ELMM3B_ 240 162 110 34,5 144 92 2x∅20+∅16

OT 25ELMM3B_ 240 162 110 34,5 144 92 2x∅25+∅16

OT 32ELMM3B_ 240 162 110 34,5 144 92 2x∅25+∅16

OT 45ELMM3B_ 240 162 110 34,5 144 92 2x∅32+∅16OT 63ELMM3B_ 240 162 110 34,5 144 92 2x∅32+∅16

OT 16ELPP3B_ 240 162 110 34,5 144 92 2x∅28,3+∅18,6

OT 25ELPP3B_ 240 162 110 34,5 144 92 2x∅28,3+∅18,6

OT 32ELPP3B_ 240 162 110 34,5 144 92 2x∅28,3+∅18,6

OT 45ELPP3B_ 240 162 110 34,5 144 92 2x∅37+∅18,6

OT 63ELPP3B_ 240 162 110 34,5 144 92 2x∅37+∅18,6

OT 80ELBB3B_ 350 233 140 34,5 250 160 Flange BOT 125ELBB3B_ 350 233 140 34,5 250 160 Flange B

OT 16ELMM3C 350 233 140 45 250 160 2x∅25+∅16

OT 25ELMM3C 350 233 140 45 250 160 2x∅25+∅16

OT 32ELMM3C 350 233 140 45 250 160 2x∅25+∅16

OT 45ELMM3C 350 233 140 45 250 160 2x∅32+∅16

OT 63ELMM3C 350 233 140 45 250 160 2x∅32+∅16

OT 16ELPP3C 350 233 140 45 250 160 2x∅28,3+∅18,6

OT 25ELPP3C 350 233 140 45 250 160 2x∅28,3+∅18,6

OT32ELPP3C 350 233 140 45 250 160 2x∅28,3+∅18,6

OT 45ELPP3C 350 233 140 45 250 160 2x∅37+∅18,6

OT 63ELPP3C 350 233 140 45 250 160 2x∅37+∅18,6

Fixing hole size in enclosure ∅ 7

Fixing hole size in enclosure ∅ 6

Type Size Cable entryEnclosed Load Break Switch H W D E X A BOT 160EFCC3B 380 280 130 45 II 355 255OT 200KFCC3B 560 280 180 45 II 535 255OT 250KFCC3B 560 280 180 45 II 535 255OT 315KFCC3B 560 380 180 45 II 535 355OT 400DFCC3B 840 380 180 45 II 815 355OT 630KFCC3B 840 380 180 45 II 815 355OT 800KFCC3B 760 560 250 45 2xII 735 535

Fixing dimensions

Page 19: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesDimension Drawings

Metal enclosed load break switches

Type Size Fixing dimensions Fixing holeEnclosed Load Break Switch H W D E A B C F G J K LOT 125ALAA3B_ 400 250 180 45 450 162 - - - 27 11 -OT 125DLAA3C_ 400 250 180 45 450 162 - - - 27 11 -

OT 160ELAA3B_ 600 250 180 45 450 162 - - - 35 11 -OT 160ELAA3C_ 600 400 230 45 450 303 - - - 35 11 -

OT 200KLAA3B_ 600 400 230 45 650 303 - - - 35 11 -OT 200KLAA3C_ 600 800 230 45 650 303 512 612 712 35 11 27

OT 250KLAA3B_ 600 400 230 45 650 303 - - - 35 11 -OT 250KLAA3C_ 800 800 230 45 850 303 512 612 712 35 11 27

OT 315KLAA3B_ 600 400 230 45 650 303 - - - 35 11 -OT 315KLAA3C_ 800 800 230 45 850 303 512 612 712 35 11 27

OT 400DLAA3B_ 800 400 230 45 850 303 - - - 35 11 -OT 400DLAA3C_ 800 800 230 45 850 303 512 612 712 35 11 27

OT 630KLAA3B_ 1000 400 230 45 1050 303 - - - 35 11 -OT 630KLAA3C_ 1000 800 230 45 1050 303 512 612 712 35 11 27

OT 800KLAA3B_ 1000 400 230 45 1050 303 - - - 35 11 -

OT 800KLAA3C_ 1000 800 230 45 1050 303 512 612 712 35 11 27

OT 1000KLAA3B_ 1200 800 230 45 1050 303 512 612 712 35 11 27

OT 1250KLAA3B_ 1200 800 330 45 1050 303 512 612 712 35 11 27

OT 1600KLAA3B_ 1200 800 330 45 1050 303 512 612 712 35 11 27

Page 20: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Load Break SwitchesDimension Drawings

Metal enclosed load break switches

Type Size Fixing dimension Fixing holeEnclosed Load Break Switch H W D E A B C F G J K L

OT 63DBUA3F-15/_ 800 400 230 45 850 303 - - - 35 - 11

OT 200KAUA3F-20/_ 1000 400 230 45 1050 303 - - - 35 - 11

OT 200KAUA3F-30/_ 1000 400 230 45 1050 303 - - - 35 - 11

OT 200KAUA3F-40/_ 1000 400 230 45 1050 303 - - - 35 - 11

OT 250KAUA3F-40/_ 1200 400 230 45 1250 303 - - - 35 - 11

OT 250KAUA3F-60/_ 1200 400 230 45 1250 303 - - - 35 - 11

OT 400DAUA3F-60/_ 1200 400 230 45 1250 303 - - - 35 - 11

OT 400DBUA3F-60/_ 1200 800 230 45 1250 303 512 612 712 35 27 11

OT 400DBUA3F-80/_ 1200 800 230 45 1250 303 512 612 712 35 27 11

OT 630KAUA3F-100/_ 1400 800 230 45 1450 303 512 612 712 35 27 11

OT 630KAUA3F-120/_ 1400 800 230 45 1450 303 512 612 712 35 27 11

Page 21: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Contents:

Technical data .................................................................................................................. 22

Ordering Information

• BS-type

- Plastic enclosed switch fuses, IP 65 ............................................................................ 23

- Steel sheet enclosed switch fuses, IP 54 .................................................................... 24

- Steel sheet enclosed switch fuses, IP 65 .................................................................... 25

• DIN-type

- Plastic enclosed switch fuses, IP 65 ............................................................................. 26

- Steel sheet enclosed switch fuses, IP 54, IP 65 ........................................................... 27

Dimension drawings ................................................................................................... 28-30

Enclosure accessories ............................................................................................... 31-35

Ordering information for cable entries from bottom and 6-pole switches entries on request.

SafeLine

Enclosed Switch Fuses

The technical data and dimensions are valid at the time of printing.We reserve the right to subsequent alternations.

Page 22: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch FusesTechnical Data, according to IEC 947-3

Enclosed switch fuse size 20 32 32 63 125 160

Rated insulated voltage Pollution degree 3 V 1000 1000 750 750 750 750

Rated impulse withstand voltage Uimp kV 12 12 12 12 12 12

Rated thermal current in ambient 40oC A 20 32 32 63 125 13560oC A 16 25 25 50 100 108

Rated operational current, AC-22A up to 500V A 20 32 32 63 125 135690V A 20 32 - 631) 1251) 1351)

Rated operational current, AC-23A up to 500V A 20 32 32 63 100 100690V A 20 32 - 401) 501) 501)

Rated conditional short-circuitcurrent r.m.s. and 80 kA, 415V kA 9 9 10 12 23 23corresponding max. allowed 100 kA, 500V kA 7.5 7.5 6 9 17 17cut-off current, peak- values 50 kA, 690V kA 6 6 - 8 14 14- The cut-off currents refer tosingle phase fuse tests

Fuse types, IEC 269-2 DIN 43620 - - 00 00 00 00BS 88 A1 A1 A2-A3 A2-A3 A2-A4 B1-B2

Max. fuse power dissipation W 3 3.5 7.5 7.5 12 9

Used switch fuse size DIN-type: OESA_ — — -00 -32_ -00 -63_ -00_ -00 -160_BS-type: OESA_ 20P_ -32P_ -32G_ -63G_ -100G_ -160B_

Cable cross section* Cu mm2 0.5...10 0.5...10 2.5...20 2.5...25Bolt size* M8x25 M8x25

Enclosed switch fuse size 200 250 315 400 630 800

Rated insulated voltage Pollution degree 3 V 1000 1000 1000 1000 1000 1000

Rated impulse withstand voltage Uimp kV 12 12 12 12 12 12

Rated thermal current in ambient 40oC A 200 250 315 400 600 72060oC A 160 200 250 320 480 570

Rated operational current, AC-22A up to 500V A 200 250 315 400 600 720690V A 200 250 315 400 600 720

Rated operational current, AC-23A up to 500V A 200 250 315 400 600 720690V A 200 250 315 400 60 720

Rated conditional short-circuitcurrent r.m.s. and 80 kA, 415V kA 40 40 40 40 75 75corresponding max. allowed 100 kA, 500V kA 40 40 40 40 75 75cut-off current, peak- values 50 kA, 690V kA 35 35 35 35 60 60- The cut-off currents refer tosingle phase fuse tests

Fuse types, IEC 269-2 DIN 43620 - 0-1 - 0-2 3 3BS 88 B1-B2 - B1-B3 B1-B4 C1-C2 C1-C3

Max. fuse power dissipation 22 23 32 34 45 55

Used switch fuse size DIN-type: OESA_ - -250D_ - -400D_ -630D_ -800D_BS-type: OESA_ -200B_ - -315B_ -400B_ -630B_ -800B_

Bolt size* M10x40 M10x40 M10x40 M10x40 M12x40 M12x401) Utilization category B* For switch fuses.

Page 23: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch Fuses, BS-typeOrdering Information

OS 20...32P

See enclosure accessories pages 31...35.

1) Other voltages up to 690V, see technical data, page 22.

OS 32G...400

Plastic enclosed switch fuses, BS-typecable entries from top and bottom, IP 65Type Ith Suitable Rated operational Flange Weight Ordering number

for fuse current 1) size+40°C type AC 22 A/ AC 23 A per

BS 88 500 V side[A] [A/A] [kg]

3-pole, no openings. Includes black handle (O-I and ON-OFF indication) N- and PE-terminals.

OS 20 PA1FUU3B 20 A1 20/20 black I-0 1.7

OS 32 PA1FUU3B 32 A1 32/32 black I-0 1.7

3-pole, Knock-out flanges. Flanges and compression glands have to be ordered separately.Includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 32 GA3FCC3B 32 A2-A3 32/32 II 2.8

OS 63 GA3FCC3B 63 A2-A3 63/63 II 2.8

OS 100 GA4FCC3B 125 A2-A4 135/100 II 4.9

OS 200 BB2FCC3B 200 B1-B2 200/200 II 13.6

OS 315 BB3FCC3B 315 B1-B3 315/315 II 14.6

OS 400 BB4FCC3B 400 B1-B4 400/400 II 14.6

4-pole, no openings. Includes black handle (O-I and ON-OFF indication) N- and PE-terminals.

OS 20 PA1FUU4B 20 A1 20/10 - 1.8

OS 32 PA1FUU4B 32 A1 32/15 - 1.8

4-pole, Knock-out flanges. Flanges and compression glands have to be ordered separately.Includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 32 GA3FCC4B 32 A2-A3 32/15 II 3.0

OS 63 GA3FCC4B 63 A2-A3 63/30 II 3.0

OS 100 GA4FCC4B 125 A2-A4 100/55 II 5.2

OS 200 BB2FCC4B 200 B1-B2 200/110 II 14.4

1SCA022280R9290

1SCA022281R0460

1SCA022281R1600

1SCA022280R6780

1SCA022280R8560

1SCA022280R9110

1SCA022281R0380

1SCA022302R6630

1SCA022280R9880

1SCA022281R1010

1SCA022280R6190

1SCA022280R7320

1SCA022280R7910

1SCA022280R9700

Page 24: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch Fuses, BS-typeOrdering Information

IP 65 available, please complete the type number with code Z.Ordering example for IP 65 enclosure: OS 20 PA1LMM3BZ

Steel sheet enclosed switch fuses, BS-typescable entries from top and bottom, IP 54Type Ith Suitable Rated operational 1) Cable entry Weight Ordering number

for fuse type current AC 22 A/AC 23 A per side [kg]+40°C BS88 500V

[A] [A/A]

3-pole, includes black handle (O-I and ON-OFF indication), N- and PE-terminals. Cable knock-outs asstandard. Compression clands have to be ordered separately.

OS 20 PA1LMM3B 20 A1 20/20 2x ø25 + ø16 4OS 32 PA1LMM3B 32 A1 32/32 2x ø25 + ø16 4

4-pole, includes black handle (O-I and ON-OFF indication), N- and PE-terminals. Cable knock-outs asstandard. Compression clands have to be ordered separately.

OS 20 PA1LMM4B 20 A1 20/20 2x ø25 + ø16 4.1OS 32 PA1LMM4B 32 A1 32/32 2x ø25 + ø16 4.1

OS 20...32

1) Other voltages up to 690V, see technical data, page 22.

See enclosure accessories pages 31...35.

1SCA022281R20801SCA022281R3210

1SCA022281R15101SCA022281R2670

Page 25: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch Fuses, BS-typeOrdering Information

5 see page 33.

OS 20...800

1 ...

1) Other voltages up to 690V, see technical data, page 22.2) The blank endplates can be replaced by the cable entries for C-flanges or ring-flanges.

See enclosure accessories pages 31...35.

Steel sheet enclosed switch fuses, BS-typescable entries from top and bottom, IP 65

Type Ith Suitable Rated operational 1) Size code Weight Ordering numberfor fuse type current AC 22 A/AC 23 A for cable [kg]

+40°C BS88 500V entry 2)

[A] [A/A]

3-pole; includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 20 PA1LUU3FZ 20 A1 20/20 1 8.5OS 32 PA1LUU3FZ 32 A1 32/32 8.5

OS 32 GA3LUU3FZ 32 A2-A3 32/32 1 9.2OS 63 GA3LUU3FZ 63 A2-A3 63/63 9.2OS 100 GA4LUU3FZ 125 A2-A4 125/100 9.8

OS 160 BB2LUU3FZ 135 B1-B2 135/100 2 19.4

OS 200 BB2LUU3FZ 200 B1-B2 200/200 3 28.3OS 315 BB3LUU3FZ 315 B1-B3 315/315 29.1

OS 400 BB4LUU3FZ 400 B1-B4 400/400 3 29.5OS 630 BC2LUU3FZ 600 C1-C2 600/600 44.4

OS 800 BC3LUU3FZ 720 C1-C3 720/720 5 65

4-pole, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 20 PA1LUU4FZ 20 A1 20/20 1 8.6OS 32 PA1LUU4FZ 32 A1 32/32 8.6

OS 32 GA3LUU4FZ 32 A2-A3 32/32 9.4OS 63 GA3LUU4FZ 63 A2-A3 63/63 1 9.4OS 100 GA4LUU4FZ 125 A2-A4 125/100 10.3

OS 160 BB2LUU4FZ 135 B1-B2 135/100 2 19.9

OS 200 BB2LUU4FZ 200 B1-B2 200/200 29.2OS 315 BB3LUU4FZ 315 B1-B3 315/315 3 29.9OS 400 BB4LUU4FZ 400 B1-B4 400/400 30.4

OS 630 BC2LUU4FZ 600 C1-C2 600/600 5 67.8OS 800 BC3LUU4FZ 720 C1-C3 720/720 71

2-pole, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 32 GA3LUU2FZ 32 A2-A3 32/32 8.8OS 63 GA3LUU2FZ 63 A2-A3 63/63 1 8.8OS 100 GA4LUU2FZ 125 A2-A4 125/100 9.4

OS 160 BB2LUU2FZ 135 B1-B2 135/100 2 19

OS 200 BB2LUU2FZ 200 B1-B2 200/200 27.1OS 315 BB3LUU2FZ 315 B1-B3 315/315 3 27.9OS 400 BB4LUU2FZ 400 B1-B4 400/400 28.3

OS 630 BC2LUU2FZ 600 C1-C2 600/600 3 39OS 800 BC3LUU2FZ 720 C1-C3 720/720 59.3

1SCA022320R84001SCA022320R8660

1SCA022320R88201SCA022320R90401SCA022320R9210

1SCA022320R9470

1SCA022320R96301SCA022320R9800

1SCA022321R00501SCA022321R0210

1SCA022321R0480

1SCA022320R75101SCA022320R77701SCA022320R7930

1SCA022320R8150

1SCA022320R83101SCA022320R85801SCA022320R8740

1SCA022320R89101SCA022320R9120

1SCA022321R06401SCA022321R0810

1SCA022321R10201SCA022320R59901SCA022320R6110

1SCA022320R6370

1SCA022320R65301SCA022320R67001SCA022320R6960

1SCA022320R71801SCA022320R7340

- Includes blank endplate on top and bottom.

Page 26: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch Fuses, DIN-typeOrdering Information

OS 00-32...400

Plastic enclosed switch fuses, DIN-typecable entries from top and bottom, IP 65Type Ith For Rated operational 1) Flange Weight Ordering number

fuse type current AC 22A/AC 23A size [kg]+40°C BS88 500V per side

[A] [A/A]

3-pole, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 00-32 A00FCC3B 32 00 32/32 ll 2.8OS 00-63 A00FCC3B 63 00 63/63 ll 3

OS 00 A00FCC3B 125 00 125/100 ll 4.9OS 00-160 A00FCC3B 135 00 135/100 ll 8

OS 250 D1FCC3B 250 0-1 250/250 ll 13.8OS 400 D2FCC3B 400 0-2 400/400 ll 14.6

4-pole, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 00-32 A00FCC4B 32 00 32/32 ll 3OS 00-63 A00FCC4B 63 00 63/63 ll 3

OS 00 A00FCC4B 125 00 125/100 ll 5.2OS 00-160 A00FCC4B 135 00 135/100 ll 8.5

OS 250 D1FCC4B 250 0-1 250/250 ll 14.4

See enclosure accessories pages 31...35.

1) Other voltages up to 690V, see technical data, page 22.

1SCA022315R18801SCA022315R2000

1SCA022315R24201SCA022315R2850

1SCA022315R3230

1SCA022315R14501SCA022315R1610

1SCA022315R22601SCA022315R2690

1SCA022315R30701SCA022315R3400

Page 27: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch Fuses, DIN-typeOrdering Information

5 see page 33

OS 00-32...800

1 ...

1) Other voltages up to 690V, see technical data, page 22.

See enclosure accessories pages 31...35.

1SCA022325R25601SCA022292R96001SCA022325R3110

1SCA022325R3530

1SCA022325R39601SCA022292R98601SCA022325R4510

1SCA022325R4930

1SCA022325R53101SCA022325R59101SCA022320R6020

1SCA022320R6450

1SCA022320R68801SCA022320R7260

1SCA022320R76901SCA022320R8070

1SCA022325R27201SCA022325R29901SCA022325R3370

1SCA022325R3700

1SCA022325R41801SCA022325R43401SCA022325R4770

1SCA022325R5150

1SCA022325R57401SCA022320R58101SCA022320R6290

1SCA022320R6610

1SCA022320R70001SCA022320R7420

1SCA022320R78501SCA022320R8230

Steel sheet enclosed switch fuses, DIN-typescable entries from top and bottomREMARKS: Enclosed switch fuses are delivered without cable entries, top and bottom sides are open.Cable entries for C-flanges or for ring-flanges have to be ordered separately, see accessories. Theseentries are used also for fixing the safety switches. Flanges have to be ordered separately, too.Black handle with 1-0 indication.

Type Ith For Rated operational 1) Size code Weight Ordering number fuse type current AC 22A/AC 23A for cable [kg]

+40°C BS88 . 500V entry[A] [A/A]

3-pole, IP 54, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 00-32 A00LAA3B 32 00 32/32 9.2OS 00-63 A00LAA3B 63 00 63/63 1 9.2OS 00A00LAA3B 125 00 125/100 9.8

OS 00-160 A00LAA3B 135 00 135/100 2 17.8

OS 250 D1LAA3B 250 0-1 250/250 28.6OS 400 D2LAA3B 400 0-2 400/400 3 29.6OS 630 D3LAA3B 600 3 600/600 43.4

OS 800 D3LAA3B 720 3 720/720 5 65

4-pole, IP 54, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 00-32 A00LAA4B 32 00 32/32 9.4OS 00-63 A00LAA4B 63 00 63/63 1 9.4OS 00A00LAA4B 125 00 125/100 10

OS 00-160 A00LAA4B 135 00 135/100 2 18

OS 250 D1LAA4B 250 0-1 250/250 3 29.4OS 400 D2LAA4B 400 0-2 400/400 30.5

OS 630 D3LAA4B 600 3 600/600 5 67.8OS 800 D3LAA4B 720 3 720/720 70.8

3-pole, IP 65, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 00-32 A00LAA3BZ 32 00 32/32 9.2OS 00-63 A00LAA3BZ 63 00 63/63 1 9.2OS 00A00LAA3BZ 125 00 125/100 9.8

OS 00-160 A00LAA3BZ 135 00 135/100 2 17.8

OS 250 D1LAA3BZ 250 0-1 250/250 28.6OS 400 D2LAA3BZ 400 0-2 400/400 3 29.6OS 630 D3LAA3BZ 600 3 600/600 43.4

OS 800 D3LAA3BZ 720 3 720/720 5 65

4-pole, IP 65, includes black handle (O-I and ON-OFF indication), N- and PE-terminals.

OS 00-32 A00LAA4BZ 32 00 32/32 9.4OS 00-63 A00LAA4BZ 63 00 63/63 1 9.4OS 00A00LAA4BZ 125 00 125/100 10

OS 00-160 A00LAA4BZ 135 00 135/100 2 18

OS 250 D1LAA4BZ 250 0-1 250/250 3 29.4OS 400 D2LAA4BZ 400 0-2 400/400 30.5

OS 630 D3LAA4BZ 600 3 600/600 5 67.8OS 800 D3LAA4BZ 720 3 720/720 70.8

Page 28: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Enclosed Switch Fuses Enclosed Switch Fuses Size Cable entry Fixing dim.BS -type DIN -type H W D E X A BOS 32GA2FCC3B OS 00-32 A00FCC3B 190 280 180 45 I I 165 255OS 32GA2FCC4B OS 00-32 A00FCC4B 190 280 180 45 I I 165 255OS 63GA3FCC3B OS 00-63 A00FCC3B 190 280 180 45 I I 165 255OS 63GA3FCC4B OS 00-63 A00FCC4B 190 280 180 45 I I 165 255OS 100GA4FCC3B OS 00 A00FCC3B 380 280 180 45 I I 355 255OS 100GA4FCC4B OS 00 A00FCC4B 380 280 180 45 I I 355 255

OS 00-160 A00FCC3B 560 380 180 45 I I 535 355OS 00-160 A00FCC4B 560 380 180 45 I I 535 355

OS 200BB2FCC3B OS 250 D1FCC3B 560 380 280 45 I I 535 355OS 200BB2FCC4B OS 250 D1FCC4B 560 380 280 45 I I 535 355OS 315BB3FCC3B 560 380 280 45 I I 535 355OS 400BB3FCC3B OS 400D2FCC3B 560 380 280 45 I I 535 355

Enclosed Switch FusesDimension Drawings

Plastic enclosed switch fuses

TypeEnclosed Switch FusesOESA-MINI-range

OS 20PA1FUU3BOS 20PA1FUU4BOS 32PA1FUU3BOS 32PA1FUU3B

Fixing hole size in enclosure ∅ 4.5

Fixing hole size in enclosure ∅ 7

Page 29: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch FusesDimension Drawings

Steel sheet enclosed switch fuses

Fixing hole size in enclosure ∅ 6

Type Fixing dimensionsEnclosed Switch Fuse H W D E X Y A B

OS 20 PA1LMM3B_ 350 233 140 45 2x∅20 ∅16 250 160OS 20 PA1LMM4B_ 350 233 140 45 2x∅20 ∅16 250 160OS 32 PA1LMM3B_ 350 233 140 45 2x∅20 ∅16 250 160OS 32 PA1LMM4B_ 350 233 140 45 2x∅20 ∅16 250 160

Cable entrySize

Page 30: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosed Switch FusesDimension Drawings

Steel sheet enclosed switch fuses

Enclosed Switch Fuses Enclosed Switch Fuses Size Fixing dimensions Fixing holeBS -type DIN -type H W D E A B C F G J K LOS 20 PA1LUU3FZ 400 250 180 45 450 162 - - - 27 11 -OS 20 PA1LUU4FZ 400 250 180 45 450 162 - - - 27 11 -0S 32 PA1LUU3FZ OS 00-32 A00LAA3B,-BZ 400 250 180 45 450 162 - - - 27 11 -0S 32 PA1LUU4FZ OS 00-32 A00LAA4B,-BZ 400 250 180 45 450 162 - - - 27 11 -OS 32 GA3LUU3FZ 400 250 180 45 450 162 - - - 27 11 -OS 32 GA3LUU4FZ 400 250 180 45 450 162 - - - 27 11 -OS 32GA3LUU2FZ 400 250 180 45 450 162 - - - 27 11 -OS 63 GA3LUU3FZ OS 00-63 A00LAA3B,-BZ 400 250 180 45 450 162 - - - 27 11 -OS 63 GA3LUU4FZ OS 00-63 A00LAA4B,-BZ 400 250 180 45 450 162 - - - 27 11 -OS 63 GA3LUU2FZ 400 250 180 45 450 162 - - - 27 11 -OS 100 GA4LUU3FZ OS 00A00LAA3B,-BZ 400 250 180 45 450 162 - - - 27 11 -OS 100 GA4LUU4FZ OS 00A00LAA4B,-BZ 400 250 180 45 450 162 - - - 27 11 -OS 100 GA4LUU2FZ 400 250 180 45 450 162 - - - 27 11 -OS 160 BB2LUU3FZ OS 00-160 A00LAA3B,-BZ 600 400 230 45 650 303 - - - 35 11 -OS 160 BB2LUU4FZ OS 00-160 A00LAA4B,-BZ 600 400 230 45 650 303 - - - 35 11 -OS 160 BB2LUU2FZ 600 400 230 45 650 303 - - - 35 11 -OS 200 BB2LUU3FZ OS 250 D1LAA3B,-BZ 800 400 330 45 850 303 - - - 35 11 -OS 200 BB2LUU4FZ OS 250 D1LAA4B,-BZ 800 400 330 45 850 303 - - - 35 11 -OS 200 BB2LUU2FZ 800 400 330 45 850 303 - - - 35 11 -OS 315 BB3LUU3FZ 800 400 330 45 850 303 - - - 35 11 -OS 315 BB3LUU4FZ 800 400 330 45 850 303 - - - 35 11 -OS 315 BB3LUU2FZ 800 400 330 45 850 303 - - - 35 11 -OS 400 BB4LUU3FZ OS 400 D2LAA3B,-BZ 800 400 330 45 850 303 - - - 35 11 -OS 400 BB4LUU4FZ OS 400 D2LAA4B,-BZ 800 400 330 45 850 303 - - - 35 11 -OS 400 BB4LUU2FZ 800 400 330 45 850 303 - - - 35 11 -OS 630 BC2LUU3FZ OS 630 D3LAA3B,-BZ 1000 400 330 45 1050 303 - - - 35 11 -OS 630 BC2LUU4FZ OS 630 D3LAA4B,-BZ 1000 800 330 45 1050 303 512 612 712 35 11 27OS 630 BC2LUU2FZ 1000 400 330 45 1050 303 - - - 35 11 -OS 800 BC3LUU3FZ OS 800 D3LAA3B,-BZ 1000 800 330 45 1050 303 512 612 712 35 11 27OS 800 BC3LUU4FZ OS 800 D3LAA4B,-BZ 1000 800 330 45 1050 303 512 612 712 35 11 27OS 800 BC3LUU2FZ 1000 400 330 45 1050 303 - - - 35 11 -

Page 31: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Contents:

Ordering Information

• Enclosure accessories for plastic enclosed switches ................................................... 32

• Enclosure accessories for metal enclosed switches ............................................... 33-34

• Compression glands ..................................................................................................... 35

• Corresponding table for cable throughouts ................................................................... 36

ABB SafeLine

Enclosure Accessories

The technical data and dimensions are valid at the time of printing.We reserve the right to subsequent alternations.

Page 32: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

Accessories for plastic enclosures

Enclosure AccessoriesOrdering Information

YMF-EPA_

YMF-MK 1042_

Type Accessory Remarks For flange Ordering numberopening

YMF-MB 10151 Cable gland-plates 4xPg13.5 IYMF-MB 10149 for knock-out flanges 4xPg16 IYMF-MB 10214 3xPg21 IYMF-MB 10537 1xPg29 I

YMF-MB 10014 12xPg16 IIYMF-MB 10015 12xPg13.5 IIYMF-MB 10016 6xPg16+4xPg21 IIYMF-MB 10017 4xPg16+3xPg29 IIYMF-MB 10019 4xPg16+2xPg36 II

YMF-MB 10215 Cover plate IYMF-MB 10546 II

YMF-MK 10437 Plate gasket IYMF-MK 10438 II

YMF-MB 10671 Plate connectors Assembly set, one pair IYMF-MB 10670 II

YMPZT 6 Compression glands Pg16YMPZT 8 for flangers Pg21

2 pcs/package

YMF-EPA 1130 Cable speader 1x ø15...30 IYMF-EPA 1230 2x ø15...30 IYMF-EPA 2160 1x ø30...60 IIYMF-EPA 2260 2x ø30...60 II

YMF-MK 10425 Rubber cushion ø15...20 IYMF-MK 10426 for cable speader ø20...30 IYMF-MK 10427 ø30...45 IIYMF-MK 10428 ø45...60 II

YMF-MK 10391 Plate extension To be mounted with four II(25 mm) YMF-MB 10392 screws

YMF-MB 10392 M8x50 screw M80x50 (4 pcs needed) II

YMF-MB 10547 Hinges Polyamid

YMF-MB 10674 Mounting lugs Plastic, for wallSet of 4 pcs mounting

YMF-MB 10597 Lock One lock, with two keys

YMF-MK 10391

YMF-MB 10547

YMF-MB 10674

YMF-MB 10597

YMF-MB_

YMF-MK 1043_

YMPZT 6, 8

YMF-MB1067_

Remark: Plate gaskets and connectors for flanges and cable speaders have to beordered separately.

1SCA022204R80701SCA022204R82301SCA022204R84001SCA010352R4520

1SCA022204R86601SCA022204R88201SCA022204R90401SCA022204R91201SCA022204R9390

1SCA022191R21701SCA022191R2330

1SCA010352R63101SCA022191R1950

1SCA022234R07201SCA022234R0990

1SCA022110R52701SCA022110R5430

1SCA022191R27601SCA022191R29201SCA022191R31401SCA022191R3310

1SCA022191R35701SCA022191R37301SCA022191R39001SCA022191R4110

1SCA022493R0600

1SCA022204R7850

1SCA010352R7710

1SCA022229R0010

1SCA022468R9010

Page 33: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosure AccessoriesOrdering Information

OEZXP __0

1

2

4

5

3

2

4

3

5

5

4

1

2

3

OEZXR 1__

OEZXR 023, 037

OEZXP __C

OEZXP __R

Type Suitable for switches Number of holes for Weight Ordering numbermarked in previous pages C- Ring-with code below. For flange flangeenclosure size WxD [mm] [pcs] [pcs] [kg]

Cable entrys without any holes, covers

OEZXP 1201) 250x180 - - 0.8

OEZXP 240 400x230 - - 1.5

OEZXP 340 400x330 - - 2

OEZXP 280 800x230 - - 3

OEZXP 380 800x330 - - 4

Cable entrys with holes for ring-flanges, divided 2)

OEZXP 24R 400x230 - 4 1.6

OEZXP 34R 400x330 - 4 2.1

OEZXP 28R 800x230 - 8 3.2

OEZXP 38R 800x330 - 8 4.2

Cable entrys with holes for C-flanges

OEZXP 120C 250x180 1 - 0.8

OEZXP 240C 400x230 2 - 1.7

OEZXP 340C 400x330 3 - 2.3

OEZXP 280C 800x230 4 - 3.4

OEZXP 380C 800x330 6 - 4.5

Cable entry gasket set for IP65 switches

OEZXX2 For IP65 switchesonly, to seal up thecable entry.

Ring-flanges for metal enclosuresType Suitable for cable Suitable for cable entry Weight Ordering number

diameter ø / [mm] [kg]

Ring-flange covers

OEZXR 023 knoc-out ø22,5 OEZXP__R 0.16OEZXR 037 knoc-out ø37 0.16

Ring-flanges for different cable diameters

OEZXR 134 ø 22...35 OEZXP__R 0.45OEZXR 143 ø 31...44 0.4OEZXR 150 ø 39...51 0.35OEZXR 158 ø 46...59 0.3

1) Knock-outs for ∅20 and ∅232) Knock-outs for ∅23 and ∅37

Cable entrys for metal enclosed switchesREMARKS: These cable entrys are also used for fixing the enclosed switches. The flanges have to beordered separately (C-flanges and ring-flanges). Remark, in IP65 switches the gasket set OEZXX2 isneeded, it has to be ordered separately.

1SCA022277R2350

1SCA022277R2780

1SCA022277R3320

1SCA022277R3910

1SCA022277R4720

1SCA022277R3160

1SCA022277R3750

1SCA022277R4560

1SCA022277R5020

1SCA022399R1440

1SCA022399R1520

1SCA022399R1610

1SCA022399R1790

1SCA022399R1870

1SCA022281R5340

1SCA022277R52901SCA022277R5450

1SCA022277R56101SCA022277R58801SCA022277R60001SCA022277R6260

Page 34: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosure AccessoriesOrdering Information

OEZXC 0

Type Suitable for flange Suitable for cable Weight Ordering numberentry [kg]

OEZXC 1R One hole for ring-flanges OEZXP__C 0.53 1SCA022281R3560+knock-outs φ21, φ23,φ29 (1pc/each)

OEZXC 2R Two holes for ring-flanges OEZXP__C 0.55 1SCA022281R3720+ one knock-out, Pg 16

OEZXC 2R

OEZXC 1R

Flange adapter 1)

Ring-flanges have to be ordered separately.

MKLZX 2

C-flanges for metal enclosuresType Suitable for flange Suitable for cable Weight Ordering number

entry [kg]

Cover plate 1)

OEZXC 0 - OEZXP__C 0.25 1SCA022277R6420

Flanges for metal and plastic enclosures 1)

Type Suitable for flange Suitable for cable Ordering numberø [mm] entry

KIG-1 15...45 -KIG-2 20...65 -KIG-221-1 20...65 II and CKIG-221-2 2x(20...65) II and C

KIG-1

KIG-2

KIG-221-1

KIG-221-2

KIG-1 and KIG-2 KIG-221-1 and KIG-221-2

1) Fixing set MKLZX2 for C-flanges have to be ordered separately.

Dimensions

Type Remarks Suitable for cable Ordering numberentry

Fixing set for C-flangesMKLZX 2 Includes rubber gasket and OEZXP__C 1SCA023215R8370

fixing accessories

1SEH5267111SEH5267121SEH5267131SEH526714

Page 35: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLineEnclosure AccessoriesOrdering Information

FHOS PK_

MRRNK_, MRRNL_

MRRPK_, MRRPL_

Compression glandsCompression glands for flanges with threaded outlets, plasticType Cable ø Flange hole Ordering number

[mm] [mm]

MRRPK 13.5 6...11 20.5MRRPK 16 8...13 22.5MRRPK 21 10...18 28

MRRPK 29 16...25 37MRRPK 36 22...33 47MRRPK 42 30...45 53

Compression glands for flanges with threaded outlets, light alloyType Cable ø Flange hole Ordering number

[mm] [mm]

MRRPL 13.5 6...11 20.5MRRPL 16 8...13 22.5MRRPL 21 10...18 28

MRRPL 29 16...25 37MRRPL 36 22...33 47MRRPL 42 30...45 53

Compression glands for flanges with knock-outs, plasticType Cable ø Flange hole Ordering number

[mm] [mm]

MRRNK 13.5 6...11 20.5MRRNK 16 8...13 22.5MRRNK 21 10...18 28

MRRNK 29 16...25 37MRRNK 36 22...33 47MRRNK 42 30...45 53

Compression glands for flanges with knock-outs, light alloyType Cable ø Flange hole Ordering number

[mm] [mm]

MRRNL 13.5 6...11 20.5

MRRNL 16 8...13 22.5MRRNL 21 10...18 28

MRRNL 29 16...25 37MRRNL 36 22...33 47MRRNL 42 30...45 53

Locking nutsType For compression glands Ordering number

FHOS PK 13.5 N MRRN__13.5FHOS PK 16 N MRRN__ 16FHOS PK 21 N MRRN__ 21

FHOS PK 29 N MRRN__ 29FHOS PK 36 N MRRN__ 36FHOS PK 42 N MRRN__ 42

1SCA022256R24601SCA010169R71201SCA010169R7210

1SCA022256R30101SCA022137R00001SCA022137R0260

1SCA022499R07601SCA010169R73901SCA010169R7470

1SCA010169R76301SCA010169R77101SCA013147R6800

1SCA022256R26201SCA010169R25901SCA010169R1010

1SCA010169R62301SCA022137R04201SCA022137R0690

1SCA012009R4700

1SCA022256R28901SCA012009R4880

1SCA012009R49601SCA022482R19001SCA022256R3430

1SCA022256R36001SCA010139R31701SCA012008R4650

1SCA012063R67901SCA022256R38601SCA022256R4080

Size D1 D2 d1 d2 L1

Pg 9 15.2 19 7 9.5 8Pg 11 18.6 22 9 11 8Pg 13.5 20.4 24 11 13 9Pg 16 22.5 27 13 15.5 10Pg 21 28.3 33 16 20.5 11Pg 29 37 42 25 27 11Pg 36 47 53 32 34 13

Page 36: Low Voltage Products - ABB Group...Plastic enclosed load break switches, grey enclosure, 3-pole, IP65 Cable entries from top and bottom Type Rated operational 1) Cable outlets Enclosure

SafeLine

36 ABB Control

Throughout FI SE GBPg 11 Pk 11 Pr 18.6Pg 16 Pk 16 Pr 22.5Pg 21 Pk 21 Pr 28.3Pg 29 Pk 29 Pr 37M 16 M 16M 20 M 20M 25 M 25M 32 M 32Flange I I Fl 13 Fl 13Flange II I I Fl 21 Fl 21Flange B B Fl 13 Fl 13Flange C C Fl 21 Fl 21

Corresponding table for cable throughouts

ABB OyLow Voltage ProductsP.O. Box 622FI-65101 VAASA, FinlandTelephone +358 10 11Telefax +358 10 22 45708http://www.abb.com/LVswitches

The technical data and dimensions are valid at thetime of printing. We reserve the right to subsequentalterations.

SYSTEMQUALITYCERTIFIEDSFS

ISO 9001

CERT

IFIED

ENVIRONMENTAL

SYSTEM

SFSISO 14001

ISO 9001 SFSBS 8800CER

TIFIED

OH

& S MANAGEMENT

-SYSTEM