Lower Maintenance.Higher Quality.Turbo Flow WSD Series

• Horizontal or vertical mount configurations• Packing or mechanical seal• Casings available in a variety of cast metals• Hydraulic balance design for steady characteristic curves• Easy low cost maintenance and parts program• Compact design• High efficiency impeller design• Clockwise or counter-clockwise rotation• Grease or oil lubricated long life roller bearings• Protective shaft sleeve

- No matter how your facility moves water, Wastecorp has the right Turbo Flow WSDSeries for you.

WSD 300-800 Medium Duty790- 8,700 GPM

WSD 1000-1600 Heavy Duty8,665- 21,700 GPM

WSD 2000-3200 Severe Duty21,842- 62,000 GPM

• Municipal water distribution• Commercial marine operations• Power generation• High volume industrial • Mining chemical extraction

MODELS

APPLICATIONS

FEATURES

® ™

Page 3: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

Turbo-Flow WSD Series pumps are single-stage, axially split double-suction pumps. Select from either horizontal or vertical mount configurations and electric or engine drives.Wastecorp’s WSD Series are designed for low life cycle costs, higher efficiencies andless down time than comparable brands.

State-of-the-art pumping technologyThis series of rugged, heavy-duty pump is engi-neered for easy maintenance, as the entire

rotation element is removable without disturbing piping or the casing. All connecting flanges are located in the lower half of the pump allowing for easy inspection without disruption or removal of any pipe work or driving devices.

The WSD Series offers high head characteristics over a wide range of flows and are available with mechanical seal or standard packing arrange-ments.

Nothing Moves Water Like The Turbo Flow WSD Split Case Series.

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 2

Uncommon Quality. Uncompromising Results. Turbo Flow WSD.

®

Above: Model WSD 1100 with a Volvo Penta diesel engine.

Page 4: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul
Page 5: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul
Page 6: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

A wide variety of mechanical seals and packing areavailable for all models.

Page 7: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul
Page 8: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul
Page 9: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

Turbo Flow Control Options

Wastecorp’s Turbo Flow split case pumps are available with a wide selection of pump controls and monitoring units to help protect your pump and promotes an easier way to maintain your equipment. Monitoring units provide dependabledata to help determine the ideal range fordata to help determine the ideal range forefficiency and reduced energy consumption

Software, power consumption tools and a varietyof panels are available for facilities of all sizes. Call a Wastecorp Pump Expert today to learn more.

Recording Pump Data Made EasySelect the right package for your needs.• Shock pulse measurement• Speed or temperature measurement• Vibration measurement

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 8

The Latest Technology forEnergy Savings and Pump Protection.

Easy-to-read display communicatesstatus information

• Real Time Clock — time-of-Day functionality• Data capture, event logs, reminder warnings

Page 10: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul
Page 11: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 10

WSD Series Split Case Pumps Pump Performance Chart (Utilizing 60 Hz / 3600 RPM Motors

WSD Series Split Case Pumps Pump Performance Chart (Utilizing 60 Hz / 1750 RPM Motors

WSD Series Split Case Pumps Pump Performance Chart (Utilizing 60 Hz / 1200 RPM Motors

WSD SERIES MODEL Pump Size¹

(inch) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)

WSD-300 3 x 5 x 14 80 3 125 5 288 1,268 154 506 350 14 130 174 204 450WSD-400 4 x 6 x 13 100 4 150 6 540 2,378 213 699 320 13 346 463 223 492WSD-500 5 x 6 x 12 125 5 200 6 780 3,434 176 576 300 12 346 463 350 772

WSD SERIES MODEL Pump Size¹

(inch) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)

WSD-300 3 x 5 x 14 80 3 125 5 180 793 63 206 350 14 38 51 204 450WSD-400 4 x 6 x 16 100 4 150 6 290 1,276 91 298 400 16 78 104 241 531WSD-500 5 x 8 x 19 125 5 200 8 522 2,298 124 406 480 19 190 255 500 1,102WSD-600 6 x 8 x 22 150 6 200 8 876 3,857 174 572 570 22 432 579 740 1,631WSD-800 8 x 10 x 26 200 8 250 10 1,296 5,706 240 789 660 26 778 1,043 1,000 2,205WSD-1000 10 x 12 x 24 250 10 300 12 1,968 8,665 189 619 610 24 968 1,298 1,400 3,086WSD-1200 12 x 14 x 28 300 12 350 14 2,856 12,575 264 865 710 28 1,935 2,595 2,600 5,732WSD-1400 14 x 16 x 25 350 14 400 16 4,440 19,549 199 654 640 25 1,728 2,317 2,570 5,666WSD-1600 16 x 18 x 24 400 16 500 18 4,920 21,662 187 613 600 24 2,160 2,897 3,200 7,055

WSD SERIES MODEL Pump Size¹

(inch) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)

WSD-2000 20 x 24 x 41 500 20 600 24 6,528 28,742 249 817 1,050 41 3,456 4,635 6,300 13,889WSD-2400 24 x 28 x 34 600 24 700 28 8,292 36,509 147 482 860 34 2,765 3,708 5,300 11,684WSD-2800 28 x 32 x 33 700 28 800 32 11,820 52,042 134 439 830 33 3,456 4,635 6,700 14,771

The following pump operates at 900 RPMWSD-3200 32 x 36 x 39 800 32 900 36 13,944 61,394 106 349 980 39 3,456 4,635 9,130 20,128

NOTES:1. Please contact the factory for proper model selection for your application.2. This is a general overview of the performance for this series of Turbo-Flow pumps.3. Optional impeller sizes are available, including trimmed impeller sizes. Contact factory for additional information.4. Wastecorp. Pumps reserves the right to make revisions to its products, performance, dimensions and specifications, and related information, without notice.

DischargeFlange Conn.

Suction Flange Conn.

Max. Impeller OD Size³

DischargeFlange Conn.

Suction Flange thgieW.xorppAdaeH.xaMyticapaC.xaM.nnoC

DischargeFlange Conn.

Suction Flange Conn. Max. Capacity Max. Head

Max. Impeller OD Size³ Max. Power Approx. Weight

Max. Power

Approx. WeightMax. Capacity Max. HeadMax. Impeller OD

Size³ Max. Power

Wastecorp Turbo Flow WSD SeriesDouble Suction Split Case, Centrifugal PumpsOverview of Performance Range Using 60 Hz Motors²

Page 12: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

11 | WASTECORP TURBO FLOW SPLIT CASE PUMPS

Wastecorp Turbo Flow WSD SeriesHorizontal Split Case, Single Stage Centrifugal PumpsPump Curves 50 Hz Motors

Page 13: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 12

WSD Series Split Case Pumps Pump Performance Chart (Utilizing 50 Hz / 2900 RPM Motors)

WSD Series Split Case Pumps Pump Performance Chart (Utilizing 50 Hz / 1450 RPM Motors)

WSD Series Split Case Pumps Pump Performance Chart (Utilizing 50 Hz / 980 RPM Motors)

WSD SERIES MODEL Pump Size¹

(mm) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)

WSD-300 80 x 125 x 350 80 3 125 5 240 1,057 107 351 350 14 75 101 204 450WSD-400 100 x 150 x 320 100 4 150 6 450 1,981 148 486 320 13 200 268 223 492WSD-500 125 x 200 x 300 125 5 200 8 650 2,862 122 400 300 12 200 268 350 772

WSD SERIES MODEL Pump Size¹

(mm) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)

WSD-300 80 x 125 x 350 80 3 125 5 150 660 44 143 350 14 22 30 204 450WSD-400 100 x 150 x 400 100 4 150 6 242 1,063 63 207 400 16 45 60 241 531WSD-500 125 x 200 x 480 125 5 200 8 435 1,915 86 282 480 19 110 148 500 1,102WSD-600 150 x 200 x 570 150 6 200 8 730 3,214 121 397 570 22 250 335 740 1,631WSD-800 200 x 250 x 660 200 8 250 10 1,080 4,755 167 548 660 26 450 603 1,000 2,205WSD-1000 250 x 300 x 610 250 10 300 12 1,640 7,221 131 430 610 24 560 751 1,400 3,086WSD-1200 300 x 400 x 710 300 12 350 14 2,380 10,479 183 600 710 28 1,120 1,502 2,600 5,732WSD-1400 350 x 400 x 640 350 14 400 16 3,700 16,291 139 454 640 25 1,000 1,341 2,570 5,666WSD-1600 400 x 500 x 600 400 16 500 18 4,100 18,052 130 426 600 24 1,250 1,676 3,200 7,055

WSD SERIES MODEL Pump Size¹

(mm) DN (mm) NPS (inch) DN (mm) NPS (inch) (m3/hr) (GPM) (m) (ft) (mm) (inch) (kW) (HP) (kg) (lb)

WSD-2000 500 x 600 x 1050 500 20 600 24 5,440 23,952 173 568 1,050 41 2,000 2,682 6,300 13,889WSD-2400 600 x 700 x 860 600 24 700 28 6,910 30,424 102 335 860 34 1,600 2,146 5,300 11,684WSD-2800 700 x 800 x 830 700 28 800 32 9,850 43,368 93 305 830 33 2,000 2,682 6,700 14,771

The following pump operates at 730 RPMWSD-3200 800 x 900 x 980 800 32 900 36 11,620 51,161 74 242 980 39 2,000 2,682 9,130 20,128

NOTES:1. Please contact the factory for proper model selection for your application.2. This is a general overview of the performance for this series of Turbo-Flow pumps.3. Optional impeller sizes are available, including trimmed impeller sizes. Contact factory for additional information.4. Wastecorp. Pumps reserves the right to make revisions to its products, performance, dimensions and specifications, and related information, without notice.

Approx. WeightMax. Capacity Max. HeadMax. Impeller OD

Size³ Max. Power

Approx. Weight

DischargeFlange Conn.

Suction Flange Conn. Max. Capacity Max. Head

Max. Impeller OD Size³ Max. Power Approx. Weight

Max. Power

DischargeFlange Conn.

Suction Flange Conn.

Max. Impeller OD Size³

DischargeFlange Conn.

Suction Flange Conn. Max. Capacity Max. Head

Wastecorp Turbo Flow WSD SeriesDouble Suction Split Case, Centrifugal PumpsOverview of Performance Range Using 50 Hz Motors²

Page 14: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

13 | WASTECORP TURBO FLOW SPLIT CASE PUMPS

WSDH Series Split Case Pumps Dimensional Chart - Pump With Steel Base

Wastecorp Turbo Flow WSD SeriesHorizontal Split Case Centrifugal PumpsDimensional Chart

WSDH TYPE MAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONS

MAX.PUMP

WEIGHT

Inlet DN1 Outlet DN2 b1 b2 B1 B2 L4 H≤ L3

(mm) (mm) (kg)

WSDH-300 125 80 26 24 330 330 415 600 300 204WSDH-400 150 100 28 24 370 370 415 760 300 241WSDH-500 200 125 30 26 450 450 515 825 366 500WSDH-600 200 150 30 28 600 500 590 1050 399 740WSDH-800 250 200 32 30 650 550 655 1240 464 1000WSDH-1000 300 250 36 32 650 550 730 1275 515 1400WSDH-1200 400 300 48 40 750 650 935 1430 748 2600WSDH-1400 450 350 44 40 750 670 910 1550 710 2570For pumps larger than 350 mm outlet, see pump dimensions mounted directly on a concrete pad.

WSDH TYPE MAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONS

MAX.PUMP

WEIGHT

Inlet DN1 Outlet DN2 b1 b2 B1 B2 L4 H≤ L3

(inches) (inches) (lb)

WSDH-300 5 3 1.02 0.94 12.99 12.99 16.34 23.62 11.81 450WSDH-400 6 4 1.10 0.94 14.57 14.57 16.34 29.92 11.81 531WSDH-500 8 5 1.18 1.02 17.72 17.72 20.28 32.48 14.41 1102WSDH-600 8 6 1.18 1.10 23.62 19.69 23.23 41.34 15.71 1631WSDH-800 10 8 1.26 1.18 25.59 21.65 25.79 48.82 18.27 2205WSDH-1000 12 10 1.42 1.26 25.59 21.65 28.74 50.20 20.28 3086WSDH-1200 16 12 1.89 1.57 29.53 25.59 36.81 56.30 29.45 5732WSDH-1400 18 14 1.73 1.57 29.53 26.38 35.83 61.02 27.95 5666For pumps larger than 16" outlet, see pump dimensions mounted directly on a concrete pad.

WSDH Series Split Case Sewage Pumps Dimensional Chart - Pump With Steel Base

Page 15: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 14

WSDH Horizontal Split Case Drawing

Wastecorp Turbo Flow WSD SeriesHorizontal Split Case, Centrifugal PumpsConcrete Foundation Mount

Page 16: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

15 | WASTECORP TURBO FLOW SPLIT CASE PUMPS

Refer to the WSDH Seriesdimensional chart formore information.

WSD Series Horizontal Split Case Pumps Dimensional Drawing

Suction Flange Discharge Flange

Wastecorp Turbo Flow WSD SeriesHorizontal Split Case, Centrifugal PumpsDimensional Drawing

NOTES:1. Pump dimensions vary. Contact factory for your project specific dimensions.2. Installation dimensions vary depending on motor and impeller size. Contact factory for actual dimensions.3. Pad dimensions, if any, vary. Contact factory for actual dimensions for your pump.

Page 17: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 16

WSDH Se ries Horizo ntal Split Case Pumps Dimensional Chart - Horizontal Pumps With No Base

WSDH TYPEMAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONS

MAX.PUMP

WEIGHTMETRIC

DIMENSIONSInletDN1

OutletDN2 S1 S2 B1 B2 e f h1 h2 h3 h4 b1 b2 b3 b4

No. of Holes

Size d (Φ) (kg)

(mm) (mm)WSDH-1600 500 400 42 38 800 750 758 980 900 557 425 500 400 400 250 250 4 42 3200WSDH-2000 600 500 56 52 1250 1050 1090 1360 1150 800 650 650 780 1050 700 500 4-8 42 6300WSDH-2400 700 600 54 48 1100 1200 1000 1275 1100 760 610 610 750 1050 600 500 4 55 5300WSDH-2800 800 700 58 54 1300 1250 1160 1440 1200 850 630 630 640 940 600 600 4 42 6700WSDH-3200 900 800 62 58 1400 1300 1270 1580 1380 920 770 770 740 1040 600 600 4 55 9130

For pumps smaller than 400 mm Outlet, see Pump Dimensions with Base

WSDH TYPEMAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONS

MAX.PUMP

WEIGHTIMPERIAL

DIMENSIONSInletDN1

OutletDN2 S1 S2 B1 B2 e f h1 h2 h3 h4 b1 b2 b3 b4

No. of Holes

Size d (Φ) (lb)

(inches) (inches)WSDH-1600 20 16 1.7 1.5 31.5 29.5 29.8 38.6 35.4 21.9 16.7 19.7 15.7 15.7 9.8 9.8 4 1-21/32 550,7WSDH-2000 24 20 2.2 2.0 49.2 41.3 42.9 53.5 45.3 31.5 25.6 25.6 30.7 41.3 27.6 19.7 4-8 1-21/32 988,31WSDH-2400 28 24 2.1 1.9 43.3 47.2 39.4 50.2 43.3 29.9 24.0 24.0 29.5 41.3 23.6 19.7 4 2-5/32 486,11WSDH-2800 32 28 2.3 2.1 51.2 49.2 45.7 56.7 47.2 33.5 24.8 24.8 25.2 37.0 23.6 23.6 4 1-21/32 177,41WSDH-3200 36 32 2.4 2.3 55.1 51.2 50.0 62.2 54.3 36.2 30.3 30.3 29.1 40.9 23.6 23.6 4 2-5/32 821,02

For pumps smaller than 16" Outlet, see Pump Dimensions with Base

Hole

Hole

Wastecorp Turbo Flow WSD SeriesHorizontal Split Case, Centrifugal PumpsConcrete Foundation Mount

Page 18: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

17 | WASTECORP TURBO FLOW SPLIT CASE PUMPS

Refer to the WSDV Seriesdimensional chart formore information.

Suction Flange Discharge Flange

WSD Series Vertical Split Case Pumps Dimensional Drawing

Wastecorp Turbo Flow WSD SeriesVertical Split Case, Centrifugal PumpsDimensional Drawing

NOTES:1. Pump dimensions vary. Contact factory for your project specific dimensions.2. Installation dimensions vary depending on motor and impeller size. Contact factory for actual dimensions.3. Pad dimensions, if any, vary. Contact factory for actual dimensions for your pump.

Page 19: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul

TECHNICAL INFORMATION

WASTECORP TURBO FLOW SPLIT CASE PUMPS | 18

WSDV Series Split Case Pumps Dimensional Chart - Vertical Pump With Steel Base

WSDV TYPEMAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONS MAX.

PUMPWEIGHTMETRIC

DIMENSIONS

InletDN1

OutletDN2 S1 S2 B1 B2 h2 h3 h4 h5 z

(mm) (mm) (kg)WSDV-300 125 80 26 24 330 330 140 225 320 735 450 204WSDV-400 150 100 28 24 370 370 170 260 300 715 520 241WSDV-500 200 125 30 26 450 450 200 305 355 870 610 500WSDV-600 200 150 30 28 600 500 300 370 400 990 740 740WSDV-800 250 200 32 30 650 550 350 430 440 1095 860 1000WSDV-1000 300 250 36 32 650 550 350 415 500 1230 830 1400WSDV-1200 400 300 44 36 700 650 350 430 570 1380 860 2097WSDV-1400 400 350 44 40 750 650 400 465 570 1380 930 1800

WSDV TYPEMAX. FLANGE DIMENSIONS MAX. PUMP DIMENSIONS MAX.

PUMPWEIGHTIMPERIAL

DIMENSIONS

InletDN1

OutletDN2 S1 S2 B1 B2 h2 h3 h4 h5 z

(inches) (inches) (lb)WSDV-300 5 3 1.02 0.94 12.99 12.99 5.51 8.86 12.60 28.94 17.72 450WSDV-400 6 4 1.10 0.94 14.57 14.57 6.69 10.24 11.81 28.15 20.47 531WSDV-500 8 5 1.18 1.02 17.72 17.72 7.87 12.01 13.98 34.25 24.02 1102WSDV-600 8 6 1.18 1.10 23.62 19.69 11.81 14.57 15.75 38.98 29.13 1631WSDV-800 10 8 1.26 1.18 25.59 21.65 13.78 16.93 17.32 43.11 33.86 2205WSDV-1000 12 10 1.42 1.26 25.59 21.65 13.78 16.34 19.69 48.43 32.68 3086WSDV-1200 16 12 1.73 1.42 27.56 25.59 13.78 16.93 22.44 54.33 33.86 4623WSDV-1400 16 14 1.73 1.57 29.53 25.59 15.75 18.31 22.44 54.33 36.61 3968

Wastecorp Turbo Flow WSD SeriesVertical Split Case, Centrifugal PumpsDimensional Chart

Page 20: Lower Maintenance. · huk tvup[vypun \up[z [v olsw wyv[lj[ `v\y w\tw huk wyvtv[lz hu lhzply ^h` [v thpu[hpu `v\y lx\pwtlu[ 4vup[vypun \up[z wyv]pkl klwlukhisl kh[h [v olsw kl[lytpul