Page 1: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

FOR MORE INFORMATION, CONTACT:

DAVID PRIOLETTI+1 630 573 [email protected]

LSC COMMUNICATIONSMATTOON PLANT6821 EAST COUNTY ROAD 1100 NORTHCOLES COUNTY

F O R S A L E

D R O N E V I D E O

Page 2: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

POWER SERVING THE BUILDING(VOLTAGE/AMPERES)+ 69kV stepped down to 13.1kV, at 13.3 MVA Outside

Substation

+ 13.1kV stepped down to 480V, with 14 substations in a centralized mezzanine located inside facility

+ Facility is equipped with two (2) natural gas 480V,3ph 120kw and 150kw emergency backup generators.

AGE OF THE ROOF + 109,900 square feet of roof was replaced in 2013 over

sections of east side of facility

+ All other areas of roof are of an unknown age

TOTAL ACREAGE + 83.61 acres

CEILING HEIGHTS + West side minimum is:

- Under Joist - 18’, 2”

+ West Side at South End minimum is:

- Under Joist - 31’, 5”

+ East side minimum is:

- Under Joist - 26’, 9”

+ Main Warehouse (east side) minimum is:

- Under Joist - 28’, 6”

+ Remote Warehouse (West side of Mfg Facility)

minimum is:

- Under Joist - 19’, 10”

P R O P E R T YO V E RV I E W

AUTOMATED PALLET RACK AND RETRIEVAL -- CAPACITY OF PALLET STORAGE

+ (3) Aisles w/ 16,416 total storage spaces

+ (3) HK Cranes automated to service (3) aisles

+ 76 bays X 18 levels X 3 aisles X 2 deep (R and L)

+ 15 levels @53” and 3 levels @ 60” high loads

EMPLOYEE PARKING

+ 794 total parking spaces in east parking lot.

+ 168 total parking spaces in north parking lot (including north of ASRS) not including ADA spaces.

+ 4 total ADA parking spaces in north parking lot

TRAILER PARKING

+ Drop Lot West = 123

+ Drop Lot East = 61

+ West of North Dock (North of Sub Station) = 15

+ West of North Dock (South of Sub Station) = 7

RAIL CARS ON SITE INSIDE AND OUT / RAIL PROVIDER

+ Rail cars can safely fit inside of the paper warehouse, Five 50’ cars and Four 60’ cars

+ Rail cars can safely fit on spur leading into the warehouse on Inbound track (used for full cars) can hold Twelve 50’ cars. Our Outbound track (used for empties) can hold Eight 50’ cars.

+ Rail cars can safely fit on the spur for by-products from crossing to crossing, it holds Four 50’ cars and from crossing to Baler room dock door, Four 50’ cars.

+ Rail cars can fit on the main spur outside of the gate near the crossing on the runaround next to the Main line can hold at least Seventeen 50’ cars.

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

Page 3: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

HEATING EQUIPMENT – BOILER SPECS

DOCKS

+ 40 (30 at main building, 10 at 90k warehouse remote building)

OFFICE SPACE

+ Two elevators servicing the office areas

+ Main office, lower floor 12,000 sq.ft (est)

+ Main office, upper floor 12,000 sq.ft (est)

+ Remote Shop office areas and rooms lower level 10,800 sq.ft (est)

+ Numerous small offices located throughout the facility

P R O P E R T YO V E RV I E W

NAMEPLATE INFORMATIONLSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR

Boiler 1 Cleaver Brooks CB200-600 L-55684 1973 200 25,106,000 600 20700

Boiler 2 Cleaver Brooks CB266-600 L-42741 1967 200 25,106,000 600 20700

Boiler 3 Cleaver Brooks CB266-600 L-42742 1967 200 25,106,000 600 20700

Boiler 4 Cleaver Brooks CB200-600 L-67540 1979 200 25,106,000 600 20700

Boiler 5 Cleaver Brooks CB200-600 L-73074 1981 200 25,106,000 600 20700

Boiler 7 Cleaver Brooks CB1200 800 200 OL101386 2001 200 32,658,500 800 27600

POWER:

+ All Boilers run off 460 3-phase

+ Boilers 1-5: rated at 35.5 A with 42.5A minimum, 142A Max rating of circuit protection

+ Boiler 7: rated at 89A with 108A minimum, 356A Max rating of circuit protection

We run our steam pressure at 90 psi

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

Page 4: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

L O C AT I O NO V E RV I E W

I N D I A NA P O L I S

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

S T. L O U I S

C H I C A G O

185

MIL

ES

135 MI L E S

1 2 0 M I L E S

L O U I S V I L L E

2 3 5 M I L E S

Page 5: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

S I T EP L A N

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

Page 6: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

F L O O RP L A N S

F R O N T O F F I C EF L O O R 1

F R O N T O F F I C EF L O O R 2

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

F R O N T O F F I C EF L O O R 1

Page 7: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

Page 8: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

A E R I A LV I E W

© 2020 CBRE Limited. Data © TeleAtlas, Google, AerialExpress, DigitalGlobe, Landiscor, USGS, i-cubed. The information contained herein (the “Information”) is intended for informational purposes only and should not be relied upon by recipients hereof. Although the Information is believed to be correct, its accuracy, correctness or completeness cannot be guaranteed and has not been verified by either CBRE Limited or any of its affiliates (CBRE Limited and its affiliates are collectively referred to herein as “CBRE”). CBRE neither guarantees, warrants nor assumes any responsibility or liability of any kind with respect to the accuracy, correctness,completeness, or suitability of, or decisions based upon or in connection with, the Information. The recipient of the Information should take such steps as the recipient may deem appropriate with respect to using the Information. The Information may change and any property described herein may be withdrawn from the market at any time without notice or obligation of any kind on the part of CBRE. The Information is protected by copyright and shall be fully enforced. Layout ID:L08 MapId:7067632

6821 E. COUNTY RD. 1100 NORTH, MATTOON, IL

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

Page 9: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

B U I L D I N GE X PA N S I O N S

LSC COMMUNICATIONS – MATTOON PLANT / FOR SALE

YEAR DESCRIPTION FIRST FLOOR 2ND FLOOR/MEZZ-ANINE

TOTAL FIRST FLOOR

2ND FLOOR/MEZZ-ANINE

TOTALFLOOR SPACE

1967 Original Building 182,186 10,155 182,186 10,155 192,341

1970 Production Building Addition 16,384 - 198,570 10,155 208,725

1973 Square off front/back 81,000 - 279,570 10,155 289,725

1977 Production Building Expansion 69,632 4,096 349,202 14,251 363,453

1978 Square off south to col. 84,168 - 433,370 14,251 447,621

1981 Charter 143,384 14,208 576,754 28,459 605,213

1989 Storage Expansion 36,000 - 612,754 28,459 461,829

1991 South Addition line 13 21,120 - 633,874 28,459 662,333

1993 Southwest square off 24,797 - 658,671 28,459 687,130

1993 Storage Expansion 16,384 - 675,055 28,459 703,514

1994 Production Building Expansion 2,125 8,925 677,180 37,384 714,564

1994 North side expansion 71,040 - 748,220 37,384 785,604

1994 Office Expansion 11,940 11,940 760,160 49,324 809,484

1996 Southeast Storage Expansion 52,000 - 812,160 49,324 861,484

1998 South Mech. Mezz expansion - 2,772 812,160 52,096 864,256

1999 North side expansion 54,000 - 866,160 52,096 918,256

2001 Production Building Expansion 128,600 - 994,760 52,096 1,046,856

1967 Production Building Expansion 4,400 - 4,400 - 4,400

1967 Fire Pump House 1,440 - 5,840 - 5,840

1967 Storage Building 800 - 6,640 - 6,640

1973 Production Building Expansion 350 - 6,990 - 6,990

1975 Morton Building 1,984 - 8,974 - 8,974

1993 Remote Warehouse 75,000 - 83,974 - 83,974

GRAND TOTAL 1,078,734 52,096 1,130,830

All figures are in square feet

Page 10: LSC COMMUNICATIONS MATTOON PLANT · 2020-05-18 · LSC DESIGNATION BRAND MODEL SERIAL # DATE MAX. PRESSURE NAT. GAS INPUT (BTU/HR. HORSEPOWER POUNDS/HR Boiler 1 Cleaver Brooks CB200-600

© 2020 CBRE, Inc. All rights reserved. This information has been obtained from sources believed reliable, but has not been verified for accuracy or completeness. You should conduct a careful, independent investigation of the property and verify all information. Any reliance on this information is solely at your own risk. CBRE and the CBRE logo are service marks of CBRE, Inc. All other marks displayed on this document are the property of their respective owners, and the use of such logos does not imply any affiliation with or endorsement of CBRE. Photos herein are the property of their respective owners. Use of these images without the express written consent of the owner is prohibited. PMStudio_March2020