Induction Units LTG induction units have been developed further continually since the first patent was registered by founder Dr. Albert Klein for an induction plant in 1915. Air flowing through a nozzle forms a free jet. It induces the surrounding air layer along at its edges and thus en- larges the flowing air volume. This „induction“ takes place within the induction device. A special construction en- trains room air (secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh air (primary air) the supply air then returns to the room for a comfortable climate. LTG induction units of the latest generation are energy- efficient and can be operated and demand-controlled with LTG SmartFlow technology Induction principle Active chilled beams, Induction units Ceiling HFFsuite SilentSuite Especially for hotels, the alternative to fan coil units Installation in ceiling compartments Sill HFV / HFVsf System SmartFlow Demand-adjusted ventilation with variable flow rate With NFC technology LHG System Indivent® Benefits of induction tech- nology in system combina- tion with highly inductive LDB linear diffusers. HFG With constant flow rate Diverse designs available HDF / HDFsf System SmartFlow Diffusing from two or four sides Ceiling grid 300/600 mm Wit NFC technology QHG Displacement ventilation with constant flow rate HDC Optimized for cooling office rooms Diffusing from one side, for installation next to a wall Ceiling grid 300 mm Floor HFB / HFBsf System SmartFlow Perfect for air conditioning of outer zones with façade glazing With NFC technology New for System SmartFlow: Now available with NFC technology. Power-off and easy parametrization and set-up with LTG NFC app.. LTG Air-Water Systems Air-Water Systems-eng-KI (08/15)

Upload: others

Post on 15-Oct-2019

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LTG Air-Water Systems water systems... · trains room air (secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh air (primary air) the supply

Induction Units

LTG induction units have been developed further continually since the first patent was registered by founder Dr. Albert Klein for an induction plant in 1915. Air flowing through a nozzle forms a free jet. It inducesthe surrounding air layer along at its edges and thus en-larges the flowing air volume. This „induction“ takes placewithin the induction device. A special construction en-trains room air (secondary air) through a heat exchanger,where it is cooled or heated. Together with the fresh air(primary air) the supply air then returns to the room for acomfortable climate. LTG induction units of the latest generation are energy-efficient and can be operated and demand-controlled withLTG SmartFlow technology

Induction principle

Active chilled beams, Induction units

Ce

ilin

g

HFFsuite SilentSuite

Especially for hotels, the alternative to fan coil units

Installation in ceiling compartments

Sil

l

HFV / HFVsf System SmartFlow

Demand-adjusted ventilation with variable flow rate

With NFC technology

LHG System Indivent®

Benefits of induction tech-nology in system combina-tion with highly inductive LDB linear diffusers.

HFG

With constant flow rate

Diverse designs available

HDF / HDFsf System SmartFlow

Diffusing from two or four sides

Ceiling grid 300/600 mm

Wit NFC technology

QHG

Displacement ventilation with constant flow rate

HDC

Optimized for cooling office rooms

Diffusing from one side, for installation next to a wall

Ceiling grid 300 mm

Flo

or

HFB / HFBsf System SmartFlow

Perfect for air conditioning of outer zones with façade glazing

With NFC technology

New for System SmartFlow:

Now available with NFC technology. Power-off and easy parametrization and set-up with LTG NFC app..

LTG Air-Water Systems

Air-Water Systems-eng-KI (08/15)

Page 2: LTG Air-Water Systems water systems... · trains room air (secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh air (primary air) the supply

LTG Air-Water Systems

Fan Coil Units

The principle: A fan conveys room air through a heat exchanger and cools or heats the room.

Fan coil units, Chilled beam

Ce

ilin

g

LVC System Indivent®

Hybrid displacement ventilation

Supply air via LDB linear diffusers

Sil

l

VFC

High cooling output

Available in different sizes and designs

VKH

Especially for hotels, even for operation at night

Installation in ceiling com-partments

QVC

Comfortable room climate by displacement ventilation

The thermal effect removes pollutants by displacement flow

VKE

For all kinds of rooms – from offices to hotel rooms

To connect air diffusers

Flo

or

VKB / VKB-N

Heating, cooling, ventilation, humidification, desiccant operation

KFA cool wave®

Chilled beam without fan

Fast eddying pulsating air jets

For supplementing passive cooling systems

SKB

Heating convector for free convection

LTG fan coil units use both radial and cross-flow fans toimplement the best flow and acoustics for different installa-tion situations. Flexible and high-performance. LTG fan convectors with cross-flow technology are charac-terized by a particularly even and large-area flow throughthe heat exchanger. Low pressure loss and low noise levelwith high cooling or heating output. The latest drive technology generation (EC-technology) alsopermits capacity modulation at the lowest electrical energyconsumption.

Air flow in the fan coil unit with tangential fan

The LTG System Design

Flexible technology for floor supply systems with a consistent appearance.

Appearance and room effect are essentially deter-mined by the architecture. LTG System Design permits different technical solutions for room air conditioningin different building areas under a visually consistentgrid.

Air-Water Systems-eng-KI (08/15)

Page 3: LTG Air-Water Systems water systems... · trains room air (secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh air (primary air) the supply

LTG Air-Water Systems

Decentralized Ventilation Units

Decentralized ventilation units offer unique flexibility in combination with high economic efficiency to architects and planners.

All ventilation is provided locally. Both supply air and exhaustare guided across the façade and treated. An integratedhighly efficient heat recuperator minimizes the heat/coldloss and thus ensures low energy costs. Without a centralAHU, decentralized systems offer the only, highly efficientsolution to renovate existing buildings in an energy-efficient manner. Local systems offer an innovative and energy-efficient means for individual, demand-controlled air condi-tioning for new construction projects as well.

Heat exchanger

Decentralized Ventilation Units

Ce

ilin

g

FVS Univent®

For schools, child day-cares and meeting rooms

Individual, demand-controlledoperation: via time control or CO2 sensor (optional)

Highly efficient heat recovery

Plug-and-play solution

Flo

or

FVPpulse

Transient air flow with high ventilation effectiveness and thermal comfort by impulse ventilation

Only one facade opening, very simple structural inte-gration without flow short circuit

Fa

çad

e

FVM

Low depth, even for integra-tion into single-shell façades

Saving floor heights, service shaft dimensions, and plant rooms

Expandable in steps from static heating to air condi-tioning

FVD / FVDplus

High heating and cooling capacity

Patented wind pressure control

Extreme security against freezing

LTG planning tools – we support you!

Ask for your own DVD with helpful tools, such as dimen-sioning programs, streaming videos and product infor-mation! Also available: our product overviews about air dif-fusers and air distribution products.

Visit us on www.LTG.de and get detailed technical infor-mation as PDF files at „Download“.

Air-Water Systems-eng-KI (08/15)

Page 4: LTG Air-Water Systems water systems... · trains room air (secondary air) through a heat exchanger, where it is cooled or heated. Together with the fresh air (primary air) the supply

LTG Air-Water Systems

LTG drives development in comfort air technology with basic innovation. We are your reliable partner in the system solutions area.

Mixed/displacement ventilation

in an extended comfort zone

The mixed/displacement air flow developed by LTGand assumed into the VDI 3804 permits high coolingoutput at high thermal comfort. It can be implementedin any LTG device type with optimized air distributors.The above chart shows the areas of application of dif-ferent flow forms that are essentially defined by ther-mal comfort. The ideal flow shape for the project-specific parameter cooling output and supply air flowrate can be implemented with different LTG air-water systems then. We perform optimization for specialrequirements within the scope of our engineering ser-vices. Products with mixed/displacement ventilation:HFV, HFG, VFC, VKB, HFB and FVD.

Areas of use of different flow types

The System SmartFlow

Induction technology redefined - demand-oriented air conditioning

The LTG System SmartFlow offers best comfort andenergy consumption even under changing load sta-tions. The ideal flow form is selected depending onrequired cooling output and fresh air volume. For this,the air nozzles are opened and the cold water valvesare controlled. This ensures best comfort, acoustics and energy efficiency for any load case with a singledevice. Manual (different room use) or automatic(occupancy or CO2-controlled) regulation is possible. Incontrast to conventional induction technology, thispermits adjustment of cooling output and fresh airsupply to the specific requirements. Products with theSmartFlow system: HDFsf, HFBsf and HFVsf.

Comparison of conventional induction technology and SmartFlow technology

The System Indivent®

Hybrid displacement ventilation

Highest comfort by combination of mixed and dis-placement flow! With LTG induction devices or fan coilunits in combination with our highly inductive LDBlinear diffusers permits sophisticated implementation of this comfortable room flow. Products with the Indivent® system: LHG and LVC. Flow chart for Indivent® system