06/06/22 1 LTG INTRODUCTION THE LTG FORMS THE INTERFACE BETWEEN THE DIGITAL ENVIRONMENT OF AN EWSD EXCHANGE AND THE SWITCHING NETWORK (SN). THE LTG PERFORM NON-CENTRAL CONTROL FUNCTIONS AND THUS RELIEVE THE COORDINATION PROCESSOR (CP) OF ROUTINE WORK. SEVERAL LTG TYPES ARE AVAILABLE FOR OPTIMAL IMPLEMENTATION OF THE VARIOUS LINE TYPES AND SIGNALING METHODS. THEY HAVE THE SAME BASIC STRUCTURE AND OPERATE ACCORDING TO THE SAME PRINCIPLES. THEY DIFFER IN FEW HW UNITS AND SPECIFIC APPLICATION PROGRAMS IN ITS MAXIMUM CONFIGURATION, THE EWSD SWITCHING SYSTEM CAN CONNECT UP TO 504 LTGS.

Upload: neeraj-kumar-singh

Post on 15-Nov-2014

298 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: ltg

08/04/23 1

LTG

 

INTRODUCTION

THE LTG FORMS THE INTERFACE BETWEEN THE DIGITAL ENVIRONMENT OF AN EWSD EXCHANGE AND THE SWITCHING NETWORK (SN).

THE LTG PERFORM NON-CENTRAL CONTROL FUNCTIONS AND THUS RELIEVE THE COORDINATION PROCESSOR (CP) OF ROUTINE WORK.

SEVERAL LTG TYPES ARE AVAILABLE FOR OPTIMAL IMPLEMENTATION OF THE VARIOUS LINE TYPES AND SIGNALING METHODS. THEY HAVE THE SAME BASIC STRUCTURE AND OPERATE ACCORDING TO THE SAME PRINCIPLES. THEY DIFFER IN FEW HW UNITS AND SPECIFIC APPLICATION PROGRAMS

IN ITS MAXIMUM CONFIGURATION, THE EWSD SWITCHING SYSTEM CAN CONNECT UP TO 504 LTGS.

Page 2: ltg

08/04/23 2

LTG

OMT PRINTER

SN

DLU LTG(B)

LTG(C)

CCNC

CPMB

CCG

SYP

LINES

TRUNKS

MTD MDD

Page 3: ltg

08/04/23 3

LTG

1   

     WITH DIGITAL TRANSMISSION LINK (PRIMARY DIGITAL CARRIER, PDC)• 

- DLUs OPERATING AT TRANSFER RATE OF 2048 KBIT/S.  • - V5.2 ACCESS NETWORK

-     FOR DIGITAL TRUNKS WITH TRANSFER RATE OF 2048 KBIT/S.

     WITH DIGITAL TRANSMISSION LINK FOR LOCAL OPERATION OF DLUs) AT TRANSFER RATES OF 4096 KBIT/S•      WITH PRIMARY RATE ACCESS (PA) :• • FOR MEDIUM-SIZE AND LARGE ISDN PBXS (ISDN SUBSCRIBERS WITH

PA) OPERATING AT TRANSFER RATE OF 2048

CONFIGURATION OPTIONS

Page 4: ltg

08/04/23 4

LTG

OTHER DETAILS:

-TRANSFER RATE ON THE SDC:LTG FROM THE LTG TO THE SN AND VICE VERSA IS 8192 KBIT/S ( 8 MBPS).

-EACH OF THESE SDCS HAS 128 TIME SLOTS ,OUT OF WHICH 127 TIME-SLOTS ARE USED FOR USER INFORMATION AND ONE TIME SLOT FOR MESSAGES.

-USER INFORMATION IS THE INFORMATION RELEVANT TO THE COMMUNICATION PARTNERS (VOICE, TEXT, DATA, IMAGES).

-MESSAGES ARE USED FOR INTERPROCESSOR COMMUNICATION IN THE EWSD SYSTEM.

OTHER DETAILS

Page 5: ltg

08/04/23 5

LTGLTG TYPES

FUNCTIONAL LTG TYPE LTG HW TYPE

TYPE B:-DLU-PBX (ISDN-PA)-V5.2 ACCESS NETWORK(ONLY TO LTG M/N/P)CAN BE EQUIPPED WITH OCANEQ,COU, MDTOG

LTG G/M/N/P

TYPE C:-TRUNKS WITH CAS SIGNALING-TRUNKS WITH CCS7 SIGNALING- CCS7 SIGNALING CHANNEL

LTG G/M/N/P

TYPE D: INTERNATIONAL TRUNKS LTG D

TYPE H: X25 DATA PACKETS FROM ISDN SUBS.

LTG H

Page 6: ltg

08/04/23 6

LTGLTG FUNCTIONS

(a) CALL PROCESSING FUNCTIONS :

-RECEIVING AND EVALUATING SIGNALS FROM TRUNK AND THE SUBS

- -SENDING SIGNALS & AUDIBLE TONES

- -SENDING MESSAGES TO THE CP AND RECEIVING COMMANDS FROM CP

- -SENDING/RECEIVING REPORTS TO/FROM THE GROUP PROCESSORS (GP)

- -SENDING/ RECEIVING ORDERS TO/FROM CCNC

- -CONTROLLING THE SIGNALS TO DLU, PA

- -ADAPTING THE LINE CONDITIONS TO THE 8 MBPS INTERFACE TO THE

SN

- -THROUGH-CONNECTION OF MESSAGES AND USER INFORMATION

Page 7: ltg

08/04/23 7

LTGLTG FUNCTIONS

(b) SAFEGUARDING FUNCTIONS :

- -DETECTING ERRORS IN THE LTG

- -DETECTING ERRORS ON THE CONNECTION PATHS WITHIN THE

EXCHANGE VIA CROSS-OFFICE CHECKS AND BIT ERROR RATIO COUNTING

(BERC)

- -TRANSFERRING ERROR MESSAGES TO THE CP

- -EVALUATING ERRORS TO DETERMINE PENETRATION RANGE

- -INITIATING MEASURES CORRESPONDING TO THE PENETRATION

RANGE

- -EXCHANGING ROUTINE TEST MESSAGES WITH THE CP SO THAT CP

CAN DETECT A FAULTY LTG

Page 8: ltg

08/04/23 8

LTGLTG FUNCTIONS

( c ) ADMINISTRATIVE FUNCTIONS :

- -SENDING MESSAGES TO THE CP FOR TRAFFIC MEASUREMENTS AND

TRAFFIC OBSERVATION

- -SWITCHING OF TEST CONNECTIONS

--TESTING OF TRUNKS AND PORT-SPECIFIC AREAS OF THE LTG USING THE

-ATE:T INTEGRATED IN EWSD AND THE ATE:TM

--INDICATING IMPORTANT INFORMATION

(E.G. CHANNEL ASSIGNMENTS) TO THE FUNCTIONAL UNITS

--CREATING, BLOCKING, RELEASING DEVICES VIA MML COMMANDS

Page 9: ltg

08/04/23 9

LTG

SUBSCRIBER CONNECTION (SN0 ACTIVE)

  

CP

nSDCSDC

SDC 1SDC

SN1

ZZ

n

1

SN0

ZZ

n

1SDC 1

SDC

LTG1LIU x

x

Time slot

xx

GP

A-side

MB0

IOP

MB1

IOP

SDC n

SDC

LTGnLIU y

y

Time slot

yy

GP

B-side

Page 10: ltg

08/04/23 10

LTG

LTG No. Active MCH. via

LTG No. Active MCH. via

X-12 SN-1X-1 SN-1 X-13 SN-0

X-2 SN-0 X-14 SN-1

X-3 SN-1 X-15 SN-0

X-4 SN-1

X-5 SN-0

X-6 SN-1

X-7 SN-0

X-8 SN-0 X-60 SN-1

X-9 SN-1 X-61 SN-0

X-10 SN-0 X-62 SN-1

X-11 SN-1 X-63 SN-0

STANDARD DISTRIBUTION OF ACTIVE MESSAGE CHANNELS

OF LTGS IN SN-HALVES

Page 11: ltg

08/04/23 11

LTG

EXCHANGE OF MESSAGES BETWEEN LTG AND CP, LTG AND LTG (SN WITH 63 LTGS)

  

CP

63

1

SN1

63

1

SN0

63

1 1

00

Time slot

00

MB0

IOP

MB1

IOP

63

00

Time slot

00

xx

xx

126 2*

2* 126

126*

2

2

126*LTG63LIU

GP

LTG1LIU

GP

-- Message channel LTG-SN/SN-LTG through connected, but not active *) Message channel SN-MB/MB-SN through connected, but not active

yy

yy

Page 12: ltg

08/04/23 12

LTG

STRUCTURE OF THE LTGG

FUNCTIONAL UNITS IN THE LINE/TRUNK UNIT (LTU) FUNCTIONAL UNITS IN THE SIGNALING UNIT (SU) GROUP SWITCH AND LINK INTERFACE UNIT (GSL) GROUP PROCESSOR (GP)

FUNCTIONAL UNITS OF LTGG

Page 13: ltg

08/04/23 13

LTG

Add. signals

SIHOSIHI

SPHO

SPHI

LTU

DIU30

LTU

COUB

LTU

CR

LTUATE:T

LTU

OCANEQ

TO/FROM SU

to/from SN

GSL

GP

FUNCTIONAL UNITS OF THE LINE/TRUNK UNIT (LTU)

DIU:LDIB

ATE:TM

ETEAE

Page 14: ltg

08/04/23 14

LTG

FUNCTIONAL UNITS IN THE SIGNALING UNIT (SU)

SU

TOGRM:CTC

LTU

ADDR. SIGNAL

SIHO

SIHI

SPHO (2 Mb/s)

SPHO (2 Mb/s)

to/from SN

GSL

GP

SPHO (2 Mb/s)

CRPCRM

LTU

Page 15: ltg

08/04/23 15

LTG

Functional Unit ‘Group switch and interface unit (GSL)’ for LTGG

SPHO/I2 Mb/s

0,10/1*

2

DATI0

DATO0

SU

GSL

GP

GS part LIU part

LTU0

LTU4/SU*

To/fromSILCB(GP)

SYNI MCHO/I

*) SPHO/I1 for LTGG with C-function (SU instead of LTU4)

SN0SN1

SN0SN1

6/1*

DATI1

DATO1

CDIM/CDAM SPHO/I 11

Page 16: ltg

08/04/23 16

LTG

  Note: SILCB(_ _ _) ONLY FOR LTG WITH DLU/PA

Functional unit “Group processor (GP)

DATO/I

DATO/I

 

CGSM     

MCH 0/1 

      

GP

GSL

GS

partLIU

part

LTU

 

SM PARTADDRESS SIGNALS

 

 

CG PART

MCH PART

PMU

SILCB

RESET SYNI

SIB O/I

SIHO to LTU/SU 

SIHI from LTU/SU to/

fromSN

LTU

CLOCK TO PMUetc

TO/

FROM

SN

Page 17: ltg

08/04/23 17

LTG

         

CR

(a) RM:CTC if CCS is used F:LTGG(b) COUB is used for conference calls

LTGG (C-FUNCTION) FRAME LAYOUT 

(a) RM:CTC if CCS is used F:LTGG(b) COUB is used for conference calls(c) DIU:LDIB instead of DIU30 in LTU0 and 1 when local DLUs are connected

(location corresponding to LTU2 and 3 are left vacant)

LTGG (B-FUNCTION) FRAME LAYOUT

LTU0......LTU3

DCC

DIU30

b

DIU30

b

DIU30

b

DIU30

b

GP

CGSM

PMU

SU SU

CR

LTU0......LTU3

DIU30

b

DIU30

b

DIU30

b

DIU30

b

CR

a

PMU

SU

CR

a

TOG

TOG

GP

CGSM

DCC

SU

         

CR

a

LTU0…......LTU4 LTU0…......LTU4SU SUSUSU

DIU30

bc

DIU30

bc

DIU30

b

DIU30

b

DIU30

bc

DIU30

bc

DIU30

b

DIU30

b

CR

CR

TOG

TOG

GSGP GP

CGSM

CGSM

PMU

PMU

SILCB

SILCB

CR

a

DCC

DCC

GS

GSL

GSL

GS GS

GSL

GSL

Page 18: ltg

08/04/23 18

LTG

FUSE BAR  F:LTGG

 LTGG LTGG

 F:LTGG

 LTGG LTGG

 

F:LTGG  LTGG

LTGG    

  F:LTGG  LTGG

LTGG

  F:LTGG

  LTGG

LTGG

LAYOUT OF LTGG RACK

Page 19: ltg

08/04/23 19

LTGTSG0.x or

SSG0.x or SN0

FUSE PANEL

F:LTG3

F:LTG2

F:LTG1

F:LTG0

TSG1x or SSG1x or SN1

*)

FUSE PANEL

F:LTG3

F:LTG2

F:LTG1

F:LTG0

*)TSG1x or

SSG1x or SN1

TSG0.x or SSG0.x or SN0

RACK FOR SWITCHING NETWORK B AND LINE/TRUNK GROUP (R:SN(B)/LTG) WITH CABLE LEAD-IN FROM

TOP AND FROM BOTTOM

Page 20: ltg

08/04/23 20

LTG

STRUCTURE OF THE LTGM

THE LTGM IS USED FOR ALL TASKS EXCEPT CONNECTION OF OCANEQ.

ONLY THREE MODULES ARE NECESSARY FOR A COMPLETE LTGM WITH FOUR PCM SYSTEMS CONNECTED.

FOR SPECIAL FUNCTION ,FOURTH MODULE CAN BE INSERTED IN LTG (FN.-B)

Page 21: ltg

08/04/23 21

LTGDETAILS OF MODULES OF LTGM

       DIU 120A OR DIU: LDIM: - DIU120A:THE 4 PCMS ARE COMBINED TOGETHER WITH THE CURRENT CONVERTER ON THIS MODULE. LOGICALLY, THIS MODULE IS TREATED AS LTU0 TO LTU3 WITH ORDINARY DIU30 MODULES. - DIU:LDIM:OPTIONALLY, THIS MODULE CAN BE USED TO CONNECT A DLU VIA A 4MBPS LOCAL DLU INTERFACE

THE GPL MODULE (GROUP PROCESSOR FOR LTGM): IT HOLDS THE PMU AND, IF REQUIRED, THE SILC FUNCTIONALITY. TWO DIFFERENT MODULES ARE USED:

-GPL: GROUP PROCESSOR FOR LTGM WITHOUT SILC FUNCTION-GPLS: GROUP PROCESSOR FOR LTGM WITH SILC FUNCTION

Page 22: ltg

08/04/23 22

LTGDETAILS OF MODULES OF LTGM

        The GSM (group switch for LTGM) : - It is a combination of GSL, TOG, RM : CTC, CR and

GCG. Depending on the available on board components, different GSM modules are used.

- The last three digits of the GSMabc modules define the module type. The 4th character (called a) designated by Y the PCM30, by Z PCM24 . For the 5th and 6th character the following table applies:

Page 23: ltg

08/04/23 23

LTGDETAIL OF MODULES OF LTGM

b c

A Eight CRPC Circuits

Yes Yes

C Eight CRMR2 Circuits

Yes Yes

D Four RM:CTC Circuits

Yes -

Example: GSMYAA and GSMYCC holds 16 CRPC and CRMR2 circuits. respectively whereas GSMYDC holds 8 CRMR2 plus 4 RM:CTC circuits.DETAILS OF GSM MODULES IN

LTGM

Page 24: ltg

08/04/23 24

LTG

DETAIL OF MODULES OF LTGM4th module in LTGM (LTU:S)

A PHMA can be installed to connect an Access Network AN via V5.2 interface.

An MDTOG can be installed to support the feature CLIP for analog subscribers. This module is used to deliver the A-party number to analog wired subscribers of the exchange. The used method is called Frequency Shift Key FSK. A MDTOG can be connected via SN to any analog DLU port of the EWSD exchange (pool solution).

A COUC can be installed to support large conferences. The new COUC module has 32 ports, which can be used in any combination (e.g. one conference with 14 subscribers and two with 9 subscribers. compensation.

An MCT can be installed to support the mid call trigger function.

An ATE : N can be installed as automatic test equipment.

Page 25: ltg

08/04/23 25

LTG

LTU

with DIU 120 A or DIU : LDIM*

LTU : S with

COUC or PHMA or MDTOG or MCT or ATE : N

GS, LIU, TOG , RM: CTC, CR, GCG

GSM

GPLPMU, SILC*

STRUCTURE OF THE LTGM

8 Mbps SDC to SN 0/1

*2 x 4 Mbps link forLocal DLU interface

Page 26: ltg

08/04/23 26

LTG

DIU

120

A,

DIU

:LD

IM

LTGMO LTGM3LTGM1 LTGM2 LTGM4

D

I

U

1

2

0

A

/

D

I

U

L

D

I

M

D

I

U

1

2

0

A

/

D

I

U

L

D

I

M

D

I

U

1

2

0

A

/

D

I

U

L

D

I

M

D

I

U

1

2

0

A

/

D

I

U

L

D

I

M

LTU:S

LTU:S

LTU:S

LTU:S

GSM

GSM

GSM

GSM

GSM

LTU:S

GPL /GPLS

G P L / G P L S

G P L / G P L S

G P L / G P L S

G P L / G P L S

D

I

U

1

2

0

A

/

D

I

U

L

D

I

M

FRAME FOR LTGM, F:LTGM ( A) (LTU:S ONLY FOR LTGM IN B FUNCTION )

Page 27: ltg

08/04/23 27

LTGFRAME, RACK FOR LTGM

LTGM HAS ONLY THREE MODULES (FOUR WITH THE OPTIONAL LTU : S)

FIVE LTGS CAN BE ACCOMODATED IN ONE FRAME

UP TO 30 LTGMS CAN BE INSTALLED IN ONE RACK.

EACH LTG HAS ITS OWN CURRENT CONVERTER, LOCATED ON THE DIU120A OR DIU:LDIM MODULE.

IN CASE OF SN(B) VERSION OF SWITCHING NETWORK, SN IS HOUSED IN A COMPOSITE RACK R:SN(B)/LTGM.

HERE TSG(B)/SSG(B) OCCUPYING TWO FRAMES WILL BE HOUSED ALONGWITH 20 LTGMS IN FOUR F:LTGM.

Page 28: ltg

08/04/23 28

LTGSTRUCTURE OF LTGN

THE LTGN IS THE NEWEST RELEASE OF THE LTG. ONLY ONE MODULE MAKES UP A COMPLETE

LTGN FOR THE BASIC TASKS THE LTGN HARDWARE COMBINES EVERY

POSSIBLE FUNCTIONAL UNIT ON THIS SINGLE MODULE, E.G. DIFFERENT CODE RECEIVERS IN LOGICAL LTU AND SU POSITIONS.

FOR SPECIAL FUNCTIONS A SECOND MODULE E.G. PHMA,MDTOG,COUC,MCT AND ATE:N BEING USED.FUNCTIONS ALREADY COVERED IN LTGM.

ANOTHER MODULE NAMELY OCEN IS USED FOR OCANEQ FUNCTIONS.

Page 29: ltg

08/04/23 29

LTGSTRUCTURE OF LTGN

DEPENDING ON THE APPLICATION, DIFFERENT MODULE TYPES ARE USED AND GIVEN IN FOLLOWING TABLE:

NAME TYPE MEMORY SILC

GPNLE LOCAL DLU INTERFACE

64 Mbyte YES

GPNLD LOCAL DLU INTERFACE

32 Mbyte YES

GPNYE PCM30 64 Mbyte YES

GPNYD PCM30 32 Mbyte YES

GPNYC PCM30 16 Mbyte NO

Page 30: ltg

08/04/23 30

LTG

DIU part GCG part CR part

SILC part

GS, LIU, TOG part

GP part

LTU:S(optional)

GPN

IOP Part

4 x PCM30 or2xLDI (4Mbps)

STRUCTURE OF THE LTGN 

COUCMDTOGPHMAMCTATE:N

8Mbps

SDC to

SN 0/1

Page 31: ltg

08/04/23 31

LTGFRAME/RACKS FOR LTGN

THERE ARE TWO DIFFERENT FRAME TYPES FOR THE LTGN. IF THE LTU : S FUNCTION IS NOT NEEDED , 16 LTGNS CAN

BE INSTALLED IN ONE FRAME (F:LTGN(A)). UP TO 64 LTG CAN BE INSTALLED IN A RACK. WHEN THE LTU: S IS NECESSARY (E.G. PHMA OR COUC),

ONLY EIGHT LTGS ARE POSSIBLE (F:LTGN(B)). IN CASE OF SN(B) , SN IS HOUSED IN A COMPOSITE RACK

R:SN(B)/LTGN. HERE TSG(B)/SSG(B) OCCUPYING TWO FRAMES WILL BE HOUSED ALONGWITH LTGNS IN THREE F:LTGN.

ANOTHER TYPE OF COMPOSITE RACK PROVIDES TWO FRAMES FOR TSG(B)/SSG(B), TWO FRAMES FOR MB/CCG(B) AND MAXIMUM OF ONE FRAME FOR LTGN.

EACH LTGN HAS ITS OWN ON-BOARD CURRENT CONVERTER. ALL LTGNS OF ONE FRAME ARE CONNECTED TO ONE PAIR OF FUSES.

Page 32: ltg

08/04/23 32

LTG

FRAME FOR LTGN, F:LTGN ( A)

GP

N

LTGN0-LTGN15

G P N

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

GPN

FRAME FOR LTGN, F:LTGN ( B)

GP

N

LTGN0-LTGN15

LTU:S

GPN

LTU:S

GPN

LTU:S

GPN

LTU:S

GPN

LTU:S

GPN

LTU:S

GPN

LTU:S

GPN

LTU:S

GPN

Page 33: ltg

08/04/23 33

LTGFRAME/RACK FOR LTGN

CR, CAN, DISP COMMANDS

CR LTG CAN LTG DISP LTG

CR LTU CAN LTU DISP LTU

CR CRMOD CAN CRMOD DISP CRMOD

STAT,CONF,DIAG COMMANDS

STAT LTG CONF LTG DIAG LTG

STAT DIU CONF DIU DIAG DIU

STAT CR CONF CR DIAG CR

STAT COU CONF COU DIAG COU

STAT OCANEQ

CONF OCANEQ

DIAG OCANEQ

STAT MDTOG

CONF MDTOG

DIAG MDTOG

Page 34: ltg

08/04/23 34

LTGSTATUS COMMANDS

STAT LTG : LTG = tsg-ltg;

NO. LTG CH0 CH1 NO. LTG CH0 CH1

0-1 ACT STB ACT 0-2 ACT ACT STB

0-3 ACT STB ACT 0-4 ACT STB ACT

0-5 ACT ACT STB 0-6 ACT STB ACT

0-7 ACT ACT STB 0-8 ACT ACT STB

. . . . . . . .

. . . . . . . .0-60 ACT STB ACT 0-61 ACT ACT STB

0-62 ACT STB ACT 0-63 ACT ACT STB

1-1 ACT STB ACT 1-2 ACT ACT STB

Page 35: ltg

08/04/23 35

LTGSTATUS COMMANDS

STAT DIU : LTG = tsg-ltg;

LTG DIU DIUTYP APPLIC OST LTG OST DIU OST PCM0-1 0 D30 CCSLDI ACT ACT

ACT0-1 1 D30 CCSDLU ACT ACT ACT0-1 2 D30 EXTLDI ACT ACT ACT  

Page 36: ltg

08/04/23 36

LTGSTATUS COMMANDS

STAT CR: LTG=TSG-LTG;LTG LCPOS CRPOS CRTYP OST LTG OST CR0-1 4-0-0 CRPC ACT ACT0-1 4-0-1 CRPC ACT ACT0-1 4-0-2 CRPC ACT ACT0-1 4-0-3 CRPC ACT ACT0-1 4-1-0 CRPC ACT ACT0-1 4-1-1 CRPC ACT ACT0-1 4-1-2 CRPC ACT ACT0-1 4-1-3 CRPC ACT ACT

0-1 0-0 CRPC ACT ACT0-1 0-1 CRPC ACT ACT0-1 0-2 CRPC ACT ACT0-1 0-3 CRPC ACT ACT0-1 1-0 CRPC ACT ACT0-1 1-1 CRPC ACT ACT0-1 1-2 CRPC ACT ACT0-1 1-3 CRPC ACT ACT

Page 37: ltg

08/04/23 37

LTGSTATUS COMMANDS

STAT COU: LTG=TSG-LTG;

LTG COU COUTY OST LTG OST COU 0-8 3 Y22 ACT ACT

Page 38: ltg

08/04/23 38

LTGCONFIGURATIONS

• The unit to be diagnosed must be MBL for fault clearance. If the Unit to be cleared is not MBL, it must be configured to MBL before fault clearance. If the unit is in ACT, it should be configured first to CBL and then to MBL. When the unit has been successfully cleared of faults it should be configured back to ACT.

• In case of Digital Interface Units (DIU) which are connected to Digital Line Units (DLU), the CONF DIU command will not work. For configuring them to some desired status, the side of the DLU to which the said DIU is connected can be configured by command CONF DLU.

CONF LTG: LTG = tst-ltg, OST = CBL;This command blocks the LTG for call processing, i.e. new seizures are no longer possible.

GENERAL PRINCIPLE:

Page 39: ltg

08/04/23 39

LTGDIAGNOSTICS

LTG DIAGNOSTICS

•THE LTG MAY BE DIAGNOSED ONLY IN MBL STATUS.

DIAG LTG: LTG=tsg-ltg, TA=ALL;

•DIAGONOSID OF SUB UNITS OF LTG•The prerequisite for carrying diagnostics on any of the above subunits is : LTG = ACT or CBL

DIU/CR/COU/OCANEQ = MBL

•The command is DIAG DIU/CR/COU/OCANEQ

Page 40: ltg

08/04/23 40

LTGCREATION OF LTG

CR LTG: LTG = 0-1, Type = LTGB, LDPARP = 12 ;

CR LTG: LTG = 0-2, Type = LTGB, LDPARP = 52;

( for V5.2 interface)

CR LTG: LTG = 0-3, Type = LTGC, LDPARP = 13 ;

CR LTG: LTG = 0-4, Type = LTGH, LDPARP = 60 ;

Page 41: ltg

08/04/23 41

LTG

CREATION OF LTU

To create a module in a LTU, two variants are distinguished:

-With application (for DIU modules) -Without application (for everything else)

VALUES FOR PARAMETER :TYPE

D30 DIU30 for PCM30 systemU07 OCANEQ equipment (OCE:SPM, OCE:SPC, OCE:MUP)Y25 COUC for multiparty service (conference) in LTGM/N COUB for multiparty service (conference) in LTGGV15 MDTOG for CLIP for analog wired subscribersPMA PHMA for LTGM/N to connect an AN via V5.2 interfaceATE TEM:LE for testingATM ATE:TM for testing

Page 42: ltg

08/04/23 42

LTG

CREATION OF LTU

VALUES FOR PARAMETER :TYPE

V01 8 code receivers for MFC:R2 signaling, TETPCPRT &TPCPRT ports

V02 8 code receivers for pushbutton dialing, TETPCPRT &TPCPRT ports

V03 8 code receivers for pushbutton dialing, TLFB & TESTNO

V04 ETEAE, TETPCPRT & TPCPRT ports

V08 TECONF ports

V09 8 code receivers for pushbutton dialing, TLF, RBS & TESTNO ports

V10 DIUPORTs, Alarm call ports

V11 TETPCPRT & TPCPRT ports

Page 43: ltg

08/04/23 43

LTG

CREATION OF LTU

VALUES FOR PARAMETER : APPLICATIONCCSCCS Trunk with Common Channel Signaling No. 7

CASCAS Trunk with Channel associated signaling

CCSDLU PDC from DLU with CCS

EXTDLU PDC from DLU without CCS

CCSLDI PDC from Local DLU with CCS

EXTLDI PDC from Local DLU without CCS

CASRCA Channel Associated Signaling for recorded announcement machines

CCSPA Signaling for Primary Access (large PABX)

V52IF Connection of AN on v5.2 interface

 

Page 44: ltg

08/04/23 44

LTGCREATION OF LTU

(a) Creation of Local DLU interface CR LTU: LTG = 0-1, LTU = 0, Type = D30, APPLIC = CCSLDI;CR LTU: LTG = 0-1, LTU = 1, Type = D30, APPLIC = CCSLDI;CR LTU: LTG = 0-1, LTU = 2, Type = D30, APPLIC = EXTLDI;CR LTU: LTG = 0-1, LTU = 3, Type = D30, APPLIC = EXTLDI;

(b) Creation of Remote DLU interface CR LTU: LTG= 0-5, LTU = 0, Type = D30, APPLIC = CCSDLU;CR LTU: LTG= 0-5, LTU = 1, Type = D30, APPLIC = CCSDLU;CR LTU: LTG= 0-5, LTU = 2, Type = D30, APPLIC = EXTDLU; CR LTU: LTG= 0-5, LTU = 3, Type = D30, APPLIC = EXTDLU;

(c) Creation of DIU 30 interface for trunks or DASCR LTU: LTG =0-3, LTU =0,Type=D30, APPLIC = CASRCA ; CR LTU: LTG =0-3, LTU =1,Type=D30, APPLIC = CASCAS ; CR LTU: LTG =0-3, LTU = 2,Type=D30, APPLIC = CCSCCS ;

Page 45: ltg

08/04/23 45

LTGCREATION OF LTU

(d) Creation of LTU other than connecting PDCs

 Creation of code receivers for DTMF dialing in LTUCR LTU : LTG= 0-1, LTU=4, Type=V03;Note: LTU 4 should be used for LTGG whereas LTU 6 should be used for LTGM or LTGN

  Creation of Conference UnitCR LTU : LTG=0-7, LTU=3, Type=Y22 ;

  Creation of LTU for ETEAECR LTU : LTG=0-6, LTU=3, Type=V04, MODVAR=1-0;

  Creation of LTU for test conference (TECONF) portsCRLTU : LTG=0-1, LTU=6, Type=V08;

 Creation of LTU for translation function (TLF), ring back service (RBS) and test numbers (TESTNO) ports CRLTU: LTG=0-1, LTU=5, Type=V09, MODVAR=0-0 & 1-0;

         

Page 46: ltg

08/04/23 46

LTGCREATION OF LTU

Creation of LTU for test phone control (TPCPRT & TETPCPRT) ports of workstation

CRLTU : LTG=0-1, LTU=7, Type=V11;      Creation of LTU for alarm call ports

CRLTU : LTG=0-3, LTU=4, Type=V10, MODVAR=0-3;

(d) Creation of LTU other than connecting PDC

Page 47: ltg

08/04/23 47

LTGCREATION OF LTU

(e) Creation of LTU for further modules in LTGM/N

Creation of MDTOG located in LTU:S CR LTU: LTG =0-5 , LTU=5, TYPE=V15 ;        Creation of LTU for PHMA CR LTU: LTG=0-2 , LTU=5, TYPE=PMA;

Page 48: ltg

08/04/23 48

LTGCREATION OF CODE RECEIVERS IN SU

CRPC IN LTG 0-1, RMCTC/CRMR2 in LTG 0-3 & CRMR2 in LTG 0-8:

CR CRMOD: LTG = 0-1, CRMOD=0,TYPE= CRPC;

CR CRMOD: LTG= 0-1, CRMOD=1, TYPE= CRPC;

CR CRMOD: LTG = 0-3, CRMOD = 0, TYPE =RMCTC;

CR CRMOD: LTG = 0-3, CRMOD = 4, TYPE = CRMR2;

CR CRMOD: LTG = 0-3, CRMOD = 5, TYPE = CRMR2;

CR CRMOD: LTG = 0-8, CRMOD = 0, TYPE =CRMR2;

CR CRMOD: LTG = 0-8, CRMOD = 1, TYPE = CRMR2;

CR CRMOD: LTG = 0-8, CRMOD = 4, TYPE = CRMR2;

CR CRMOD: LTG = 0-8, CRMOD = 5, TYPE = CRMR2;

Page 49: ltg

08/04/23 49

LTGTo display existing LTGs/LTUs/CRs

DISP LTG : LTG = 0-x;LTG TYPE LDPARP0-1 LTGB 120-2 LTGB 520-3 LTGC 130-4 LTGH 60

DISP CRMOD : LTG = 0-1 ;

LTG CRMOD TYPE

0-1 0 CRPC

0-1 1 CRPC

Page 50: ltg

08/04/23 50

LTGTo display existing LTGs/LTUs/CRs

DISPLTU: LTG=0-1;

LTG LTU TYPE

APPLIC MOD VAR

0-1 0 D30 CCSLDI 0-1& 1-1& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 1 D30 CCSDLU

0-1& 1-1& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 2 D30 EXTLDI 0-1& 1-1& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 3 V04 0-1& 1-0& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 4 V09 0-1& 1-1& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 5 V03 0-0& 1-0& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 6 V08 0-1& 1-1& 2-1& 3-1& 4-1& 5-1& 6-1

0-1 7 V10 0-3& 1-1& 2-1& 3-1& 4-1& 5-1& 6-1

Page 51: ltg

08/04/23 51

LTGLINE TRUNK GROUP

THANK YOU