luminous intensity test report page 1 of 13 intensity test report page 1 of 13 ... 1319 1274 1230...
TRANSCRIPT
Luminous Intensity Test Report Page 1 Of 13
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,135.9
UNIT:cd
C90/270,115.2
AVERAGE BEAM ANGLE(50%):125.5 DEG
0
400
800
1200
1600
2000
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)10
14
18
22
26
30
34
38
42
46
500.0 17.0 34.0
S(m)9.808.206.504.903.30
1.601.300.82000.65000.4900
W/ml 40.011 :ffEATAD CIRTEMOTOHPPMAL FO ATAD
MODEL
NOMINAL POWER(W)
RATED VOLTAGE(V)
NOMINAL FLUX(lm)
LAMPS INSIDE
TEST VOLTAGE(V)
Imax(cd)
LOR(%)
TOTAL FLUX(lm)
CIE CLASS
up(%)
down(%)
η
η
S/MH(C0/180)
S/MH(C90/270)
UP,DN(C0-180)
UP,DN(C180-360)
CIBSE SHR NOM
CIBSE SHR MAX
η
η
R2DG160418051-10
50
120
5399.62
1
120.0
1632
100.0
5399.6
DIRECT
0.1
99.9
1.32
1.28
0.0,50.0
0.0,50.0
1.50
1.50
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 2 Of 13
ZONAL FLUX DIAGRAM
ZONAL FLUX DIAGRAM:
γ
10 0- 10
20 10- 20
30 20- 30
40 30- 40
50 40- 50
60 50- 60
70 60- 70
80 70- 80
90 80- 90
100 90-100
110 100-110
120 110-120
130 120-130
140 130-140
150 140-150
160 150-160
170 160-170
180 170-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp γ Φ Φ
DEG LUMINOUS INTENSITY:cd Less than 25% Percent = 10.2 % UNIT:lm
1611 1609 1606 1609 1611 1609 1606 1609 154.7 154.7 2.86,2.86
1547 1538 1530 1538 1547 1538 1530 1538 446.0 600.7 11.1,11.1
1445 1423 1402 1423 1445 1423 1402 1423 685.4 1286 23.8,23.8
1319 1274 1230 1272 1319 1272 1230 1274 846.7 2133 39.5,39.5
1171 1094 1011 1098 1171 1098 1011 1094 916.6 3049 56.5,56.5
986.2 892.7 750.0 899.3 986.2 899.3 750.0 892.7 885.8 3935 72.9,72.9
770.0 661.7 459.6 669.6 770.0 669.6 459.6 661.7 755.8 4691 86.9,86.9
426.4 394.4 170.1 399.9 426.4 399.9 170.1 394.4 534.2 5225 96.8,96.8
0.4616 0.5128 1.924 0.7739 0.4616 0.7739 1.924 0.5128 169.8 5395 99.9,99.9
0.4973 0.4311 0.5312 0.4624 0.4973 0.4624 0.5312 0.4311 0.6161 5396 99.9,99.9
0.5589 0.4788 0.5415 0.5211 0.5589 0.5211 0.5415 0.4788 0.5342 5396 99.9,99.9
0.5831 0.5730 0.6103 0.5856 0.5831 0.5856 0.6103 0.5730 0.5417 5397 99.9,99.9
0.7550 0.7782 0.7144 0.8652 0.7550 0.8652 0.7144 0.7782 0.5977 5397 100,100
1.063 0.9154 0.8404 1.004 1.063 1.004 0.8404 0.9154 0.6737 5398 100,100
1.168 1.213 1.008 1.243 1.168 1.243 1.008 1.213 0.6711 5399 100,100
1.191 1.209 1.235 1.213 1.191 1.213 1.235 1.209 0.5536 5399 100,100
1.076 1.169 1.292 1.211 1.076 1.211 1.292 1.169 0.3369 5400 100,100
1.067 1.188 1.289 1.139 1.067 1.139 1.289 1.188 0.1145 5400 100,100
Conical surface Flux(90deg): 2588.6 lm
%lum = 47.9%
%lamp = 47.9%
Conical surface Flux(120deg): 3935.2 lm
%lum = 72.9%
%lamp = 72.9%
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 3 Of 13
LUMINANCE LIMITATION CURVES
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
LUMINANCE LIMITATION CURVES
)xl( ECNANIMULLISSALCERALG
1.15 A 2000 1000 500 <=300
003=<00500010002B05.1
003=<00500010002C58.1
003=<00500010002D02.2
003=<00500010002E55.2
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3
4
68
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)
G(DEG) C0/180 C90/270
85 17726 6625
80 24617 9792
75 24943 11983
70 22571 13433
65 20910 14360
60 19773 14996
55 18924 15423
50 18257 15720
45 17722 15923
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 4 Of 13
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
cc
w
fc
ρ
ρ
ρ
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
1.19
1.02
.88
.76
.67
.60
.54
.48
.44
.40
.37
1.19
.97
.80
.68
.58
.50
.44
.39
.35
.32
.29
1.19
.93
.74
.61
.51
.43
.38
.33
.29
.26
.24
1.16
.00
.86
.75
.66
.59
.53
.48
.43
.40
.37
1.16
.95
.79
.67
.57
.50
.44
.39
.35
.32
.29
1.16
.91
.73
.60
.50
.43
.37
.33
.29
.26
.24
1.11
.95
.82
.72
.63
.56
.51
.46
.42
.39
.36
1.11
.92
.76
.65
.56
.49
.43
.38
.34
.31
.28
1.11
.89
.71
.59
.50
.43
.37
.33
.29
.26
.23
1.06
.91
.79
.69
.61
.54
.49
.45
.41
.38
.35
1.06
.89
.74
.63
.54
.47
.42
.38
.34
.31
.28
1.06
.86
.70
.58
.49
.42
.37
.32
.29
.26
.23
1.02
.88
.76
.66
.59
.52
.47
.43
.40
.36
.34
1.02
.85
.72
.61
.53
.46
.41
.37
.33
.30
.28
1.02
.83
.68
.57
.48
.42
.36
.32
.29
.26
.23
.00
.81
.66
.55
.46
.39
.34
.30
.27
.24
.21
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k
2
3
4
5
6789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
2
3
4
H=5H=5
55
66
77
H=8H=8
CONDITIONS
FLUX 1000lm
FACTOR 0.70
Hdown 0.00m
Hwork 0.80m
Ework(AVE) 100lx
ρ (%) cc w fc
70 50 30
50 30 20
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 5 Of 13
WEC AND CCEC
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
cc
w
fc
ρ
ρ
ρ
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
.343
.316
.289
.264
.242
.223
.206
.192
.179
.168
.195
.173
.154
.137
.123
.112
.102
.094
.087
.081
.062
.053
.046
.040
.036
.032
.029
.026
.024
.022
.336
.310
.283
.259
.237
.219
.203
.189
.176
.166
.192
.171
.152
.135
.122
.111
.101
.093
.086
.080
.061
.053
.046
.040
.035
.032
.029
.026
.024
.022
.323
.298
.272
.249
.229
.211
.196
.183
.171
.161
.185
.166
.148
.132
.119
.108
.099
.091
.085
.079
.059
.051
.045
.039
.035
.032
.029
.026
.024
.022
.310
.287
.262
.240
.221
.204
.190
.177
.166
.156
.179
.161
.144
.129
.117
.106
.097
.090
.083
.078
.057
.050
.044
.039
.035
.031
.028
.026
.024
.022
.299
.277
.253
.232
.214
.198
.184
.172
.161
.152
.173
.156
.140
.126
.114
.104
.096
.088
.082
.076
.056
.049
.043
.038
.034
.031
.028
.026
.024
.022
cc
w
fc
ρ
ρ
ρ
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
.191
.183
.176
.169
.161
.153
.146
.139
.132
.126
.120
.191
.156
.132
.115
.102
.092
.083
.077
.071
.066
.062
.191
.132
.096
.072
.057
.046
.039
.033
.029
.025
.023
.163
.157
.151
.145
.138
.132
.125
.119
.114
.108
.103
.163
.134
.114
.099
.088
.079
.072
.066
.061
.057
.053
.163
.114
.083
.063
.049
.040
.034
.029
.025
.022
.020
.111
.107
.103
.099
.095
.091
.087
.083
.079
.075
.072
.111
.092
.079
.069
.061
.055
.051
.047
.043
.040
.038
.111
.079
.058
.044
.035
.028
.024
.020
.018
.016
.014
.064
.062
.060
.057
.055
.053
.050
.048
.046
.044
.042
.064
.053
.046
.040
.036
.033
.030
.027
.025
.024
.022
.064
.046
.034
.026
.021
.017
.014
.012
.011
.009
.008
.020
.020
.019
.018
.018
.017
.016
.015
.015
.014
.014
.020
.017
.015
.013
.012
.011
.010
.009
.008
.008
.007
.020
.015
.011
.008
.007
.006
.005
.004
.003
.003
.003
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 6 Of 13
UGR(Unified Glare Rating) Table
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
ceiling/cavity
walls
working plane
Room dimensions Viewed crosswise Viewed endwise
0.7 0.7
0.5 0.5
0.2 0.2
0.7 0.7
0.3 0.3
0.2 0.2
0.5 0.5
0.5 0.5
0.2 0.2
0.5 0.5
0.3 0.3
0.2 0.2
0.3 0.3
0.3 0.3
0.2 0.2
x = 2H y = 2H
3H
4H
6H
8H
12H
4H 2H
3H
4H
6H
8H
12H
8H 4H
6H
8H
12H
12H 4H
6H
8H
23.4 22.3 25.0 23.9 23.7 22.6 25.2 24.1 25.4 24.3
25.7 23.8 27.2 25.3 26.0 24.1 27.4 25.6 27.7 25.8
26.8 24.4 28.2 25.9 27.1 24.8 28.5 26.1 28.8 26.4
27.7 24.8 29.1 26.2 28.1 25.2 29.3 26.4 29.6 26.7
28.0 24.9 29.3 26.2 28.4 25.3 29.6 26.5 29.9 26.8
28.2 25.0 29.4 26.2 28.5 25.3 29.7 26.5 30.0 26.8
24.1 23.2 25.5 24.6 24.4 23.5 25.7 24.9 26.0 25.2
26.6 25.0 27.8 26.2 26.9 25.4 28.1 26.5 28.4 26.9
27.9 25.8 29.0 26.9 28.2 26.1 29.3 27.2 29.7 27.6
29.0 26.3 30.0 27.3 29.4 26.7 30.3 27.7 30.7 28.1
29.3 26.5 30.3 27.4 29.7 26.9 30.6 27.8 31.0 28.2
29.5 26.5 30.4 27.4 29.9 27.0 30.8 27.8 31.2 28.2
28.2 26.4 29.2 27.4 28.6 26.9 29.5 27.8 29.9 28.2
29.5 27.2 30.3 28.0 30.0 27.7 30.7 28.5 31.2 28.9
30.0 27.5 30.7 28.2 30.5 28.0 31.1 28.7 31.6 29.1
30.3 27.7 30.9 28.3 30.8 28.2 31.3 28.8 31.8 29.3
28.2 26.6 29.1 27.5 28.7 27.0 29.5 27.8 29.9 28.3
29.6 27.5 30.3 28.2 30.1 28.0 30.7 28.6 31.2 29.1
30.1 27.9 30.8 28.5 30.6 28.3 31.2 28.9 31.7 29.4
Variations with the observer position at spacings:
S = 1.0H + 0.1 / - 0.1 + 0.1 / - 0.2
1.5H + 0.1 / - 0.2 + 0.2 / - 0.3
2.0H + 0.1 / - 0.3 + 0.2 / - 0.4
CIE Pub.117 Corrected 5400 lm Total Lamp Luminous Flux.(8log(F/F0) = 5.9)
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 7 Of 13
UTILIZATION FACTORS TABLE
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 55 43 35 54 42 35 53 42 35 28
0.80 65 52 45 64 52 44 62 51 44 37
1.00 73 61 53 72 60 53 69 62 52 45
1.25 80 69 61 79 68 61 76 67 60 52
1.50 85 75 67 83 74 66 80 72 65 57
2.00 92 83 76 91 82 75 87 80 74 65
2.50 97 88 82 95 87 81 91 84 79 70
3.00 100 93 87 98 91 86 94 88 83 74
4.00 105 98 93 102 97 92 98 93 89 80
5.00 107 102 97 105 100 96 100 96 93 83
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 8 Of 13
ISOCANDELA DIAGRAM
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
HORIZONTAL(DEG)
VERTICAL(DEG)
Imax:1636(H0.0,V0.0) (At:C=270.0,Gamma=0.0)
UNIT: cd
10% 163.620% 327.330% 490.940% 654.550% 818.260% 981.870% 114580% 130990% 1473
MAX = 1636.4 MIN = 1038.4 AVG = 1413.9 AVG/MAX = 0.86MIN/MAX = 0.63
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 9 Of 13
AAI Figure
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
1m 395.93cm322.4,1636lx
2m 791.87cm80.61,409.1lx
3m 1187.80cm35.83,181.8lx
4m 1583.73cm20.15,102.3lx
5m 1979.66cm12.90,65.45lx
Height Eavg,Emax DiameterAngle:126.40deg
Flux out:4258 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 10 Of 13
ISOLUX DIAGRAM
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
131.2' 40.00m
105.0' 32.00m
32.00m
105.0'
78.7' 24.00m
52.5' 16.00m
16.00m
52.5'
26.2' 8.00m
0.0' 0.00m
0.00m
0.0'
26.2' 8.00m
52.5' 16.00m
16.00m
52.5'
78.7' 24.00m
105.0' 32.00m
32.00m
105.0'
131.2' 40.00m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.4909lx 0.04561fc
5% 0.8182lx 0.07601fc
10% 1.636lx 0.152fc
30% 4.909lx 0.4561fc
50% 8.182lx 0.7601fc
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 11 Of 13
LED Avg.L Report
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
2m/dcLgvA
75802va)56(081~0_L
18842va)57(081~0_L
18671va)58(081~0_L
46341va)56(072~09_L
78911va)57(072~09_L
7266va)58(072~09_L
38581va)56(54_L
31802va)57(54_L
09502va)58(54_L
Standard: GB/T 29293-2012
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 12 Of 13
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25
Distance(m)
0
2
4
6
8
10
12
14
16
18
20E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks:
Luminous Intensity Test Report Page 13 Of 13
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME: 2x4 Luminaires for Ambient Lighting of interior
SPEC.:N/A
MFR.: Cyber Tech
TYPE:N/A
DIM.: N/A
SUR.:N/A
WEIGHT:N/A
SERIAL No.:N/A
Shielding Angle:N/A
Test:U:120.1V I:0.4108A P:49.07W PF:0.9950 Lamp Flux:5399.62x1 lm
(DEG)γ
C(DEG) Table--1 UNIT: cd
0
0 1632
5 1627
10 1611
15 1584
20 1547
25 1500
30 1445
35 1384
40 1319
45 1250
50 1171
55 1083
60 986
65 881
70 770
75 644
80 426
85 154
90 0.46
95 0.45
100 0.50
105 0.54
110 0.56
115 0.57
120 0.58
125 0.65
130 0.75
135 0.93
140 1.06
145 1.17
150 1.17
155 1.22
160 1.19
165 1.10
170 1.08
175 1.11
180 1.07
22.5
1632
1627
1610
1583
1544
1496
1439
1375
1306
1233
1151
1061
963
856
742
621
427
162
6.03
0.43
0.48
0.52
0.53
0.54
0.56
0.63
0.78
0.94
1.08
1.17
1.14
1.22
1.20
1.13
1.07
1.14
1.11
45
1632
1626
1609
1579
1538
1486
1423
1351
1274
1187
1094
996
893
782
662
534
394
174
0.51
0.39
0.43
0.47
0.48
0.49
0.57
0.69
0.78
0.84
0.92
0.98
1.21
1.25
1.21
1.12
1.17
1.22
1.19
67.5
1632
1626
1607
1575
1532
1476
1408
1330
1243
1143
1033
915
791
663
533
402
271
137
2.20
0.37
0.40
0.48
0.52
0.53
0.59
0.60
0.72
0.74
0.92
1.05
1.14
1.12
1.21
1.24
1.27
1.32
1.26
90
1632
1626
1606
1574
1530
1472
1402
1321
1230
1126
1011
885
750
607
460
310
170
57.8
1.92
0.47
0.53
0.56
0.54
0.55
0.61
0.66
0.71
0.79
0.84
0.93
1.01
1.11
1.24
1.26
1.29
1.33
1.29
112.5
1632
1626
1607
1576
1532
1476
1408
1330
1241
1144
1035
919
798
673
547
417
284
143
3.28
0.40
0.42
0.47
0.53
0.55
0.62
0.65
0.73
0.78
0.94
1.06
1.13
1.22
1.29
1.25
1.27
1.29
1.23
135
1632
1626
1609
1579
1538
1486
1423
1352
1272
1187
1098
1002
899
789
670
543
400
185
0.77
0.41
0.46
0.50
0.52
0.53
0.59
0.74
0.87
0.96
1.00
1.04
1.24
1.27
1.21
1.21
1.21
1.23
1.14
157.5
1632
1627
1610
1583
1545
1496
1439
1375
1305
1230
1151
1064
967
860
746
625
430
171
8.52
0.46
0.51
0.55
0.56
0.56
0.59
0.66
0.80
0.96
1.10
1.18
1.15
1.22
1.21
1.11
1.12
1.15
1.07
180
1632
1627
1611
1584
1547
1500
1445
1384
1319
1250
1171
1083
986
881
770
644
426
154
0.46
0.45
0.50
0.54
0.56
0.57
0.58
0.65
0.75
0.93
1.06
1.17
1.17
1.22
1.19
1.10
1.08
1.11
1.07
202.5
1632
1627
1610
1583
1545
1496
1439
1375
1305
1230
1151
1064
967
860
746
625
430
171
8.52
0.46
0.51
0.55
0.56
0.56
0.59
0.66
0.80
0.96
1.10
1.18
1.15
1.22
1.21
1.11
1.12
1.15
1.07
225
1632
1626
1609
1579
1538
1486
1423
1352
1272
1187
1098
1002
899
789
670
543
400
185
0.77
0.41
0.46
0.50
0.52
0.53
0.59
0.74
0.87
0.96
1.00
1.04
1.24
1.27
1.21
1.21
1.21
1.23
1.14
247.5
1632
1626
1607
1576
1532
1476
1408
1330
1241
1144
1035
919
798
673
547
417
284
143
3.28
0.40
0.42
0.47
0.53
0.55
0.62
0.65
0.73
0.78
0.94
1.06
1.13
1.22
1.29
1.25
1.27
1.29
1.23
270
1632
1626
1606
1574
1530
1472
1402
1321
1230
1126
1011
885
750
607
460
310
170
57.8
1.92
0.47
0.53
0.56
0.54
0.55
0.61
0.66
0.71
0.79
0.84
0.93
1.01
1.11
1.24
1.26
1.29
1.33
1.29
292.5
1632
1626
1607
1575
1532
1476
1408
1330
1243
1143
1033
915
791
663
533
402
271
137
2.20
0.37
0.40
0.48
0.52
0.53
0.59
0.60
0.72
0.74
0.92
1.05
1.14
1.12
1.21
1.24
1.27
1.32
1.26
315
1632
1626
1609
1579
1538
1486
1423
1351
1274
1187
1094
996
893
782
662
534
394
174
0.51
0.39
0.43
0.47
0.48
0.49
0.57
0.69
0.78
0.84
0.92
0.98
1.21
1.25
1.21
1.12
1.17
1.22
1.19
337.5
1632
1627
1610
1583
1544
1496
1439
1375
1306
1233
1151
1061
963
856
742
621
427
162
6.03
0.43
0.48
0.52
0.53
0.54
0.56
0.63
0.78
0.94
1.08
1.17
1.14
1.22
1.20
1.13
1.07
1.14
1.11
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEGγγ
Test Speed: 10.0deg/s Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.351Temperature:25.3DEG Humidity:48%
Test Distance:2.437m [K=1.0000]Operators:benTest Date:2016-05-17 Remarks: